1 EINLEITUNG - Dr. Neuhaus Telekommunikation GmbH
1 EINLEITUNG - Dr. Neuhaus Telekommunikation GmbH
1 EINLEITUNG - Dr. Neuhaus Telekommunikation GmbH
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Version:<br />
Date:<br />
4.00<br />
2.2 Meters<br />
26.10.2012<br />
<strong>Dr</strong>. <strong>Neuhaus</strong> <strong>Telekommunikation</strong> <strong>GmbH</strong><br />
Page 6/27<br />
User Manual<br />
gMUC – Configuration<br />
This screen shows a list of the available meters. Further details on the meter are also shown for each entry (address, measured<br />
variables, etc.).<br />
Before the values from one of the meters are recorded by the gMUC, that meter has to be activated – to do so, click the button<br />
marked ‘Activate”, which appears if the meter is not yet registered in the gMUC.<br />
For W-MBUS meters, the W-MBUS identifiers are mapped on standardized OBIS numbers in the gMUC. If this mapping<br />
process is incomplete or defective for a meter, this will be displayed on the screen. The mapping then has to be adjusted<br />
accordingly in the gMUC. If the meter data received from a W-MBUS meter is encrypted, the meter must first be activated (click<br />
‘Activate’), and then store the corresponding AES key in the configuration of the meter (Chapter 3.5).<br />
Figure 3: Status - Meter