Luna SA 4.4.3 - Secure Support - SafeNet
Luna SA 4.4.3 - Secure Support - SafeNet
Luna SA 4.4.3 - Secure Support - SafeNet
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Component<br />
PED I 1.12<br />
PED II 2.0.2<br />
PED IIr (Remote PED) (requires PED workstation s/w on PC)<br />
[optional]<br />
1U<br />
2.2.0<br />
IKey (for PED II) 1000<br />
Client 4.4.1<br />
Note 1<br />
You can use backup tokens at firmware 4.5.3 with <strong>Luna</strong> <strong>SA</strong> at firmware 4.6.8 or 4.8.1, provided you do not use the ARIA<br />
cipher (which was not supported in 4.5.3). However, we generally recommend that you update to token firmware 4.8.1.<br />
Note 2<br />
Appliance software <strong>4.4.3</strong> requires installed HSM firmware 4.6.8 or 4.8.1. Both firmware versions are FIPS-validated.<br />
Software and firmware upgrade paths<br />
The following table lists the upgrade paths for 1U <strong>Luna</strong> <strong>SA</strong> appliances running release 4.2.0 or higher software.<br />
Component From Version To Version<br />
Client software 4.4.0 4.4.1<br />
Appliance software 4.4.0 or 4.4.1 <strong>4.4.3</strong><br />
HSM firmware 4.6.8 or 4.8.1 No change<br />
If your <strong>Luna</strong> <strong>SA</strong> equipment is at any other starting point, please refer to the <strong>Luna</strong> <strong>SA</strong> 4.2 CRN and update instructions in<br />
order to bring your system to that approved (tested and supported) starting point before you begin the upgrade to <strong>Luna</strong><br />
<strong>SA</strong> <strong>4.4.3</strong> and firmware 4.6.8 or 4.8.1. Otherwise, contact <strong>SafeNet</strong> Customer <strong>Support</strong>.<br />
Legacy 2U models of <strong>Luna</strong> <strong>SA</strong> (with the orange front-panel-cover) are not supported for this release. Do not attempt to<br />
update the old 2U models. For FIPS compliance, <strong>Luna</strong> <strong>SA</strong> 4.3.2 and firmware 4.6.8 were your last stop.<br />
<strong>Luna</strong> <strong>SA</strong> 4 hardware refresh<br />
Due to end-of-life or near end-of-life conditions on several components, a new hardware variant of the <strong>Luna</strong> <strong>SA</strong> 4 platform<br />
was released in July 2011. As a result of the hardware refresh, you must use new part numbers when ordering the <strong>Luna</strong><br />
<strong>SA</strong> 4 product. The old part numbers are no longer valid. For more information, see "Hardware revisions and part<br />
numbers" below.<br />
The hardware refresh has introduced some minor changes to the operational behavior of the product, as described in the<br />
following sections:<br />
SNMP enabled by default<br />
SNMP is enabled by default on the hardware-refresh platform.<br />
New network LED behavior<br />
The following table describes the behavior of the network status LEDs on the hardware-refresh platform.<br />
LED color LED state Ethernet link and activity<br />
Green Blinking 100 Mbps or 1000 Mbps link speed<br />
Steady on<br />
Link established. Communication activity not detected.<br />
<strong>Support</strong> added for gigabit Ethernet<br />
The Ethernet ports now support 10 Mbps, 100 Mbps, and 1000 Mbps link speeds.<br />
<strong>Luna</strong> <strong>SA</strong> <strong>4.4.3</strong> Customer Release Notes 007-011327-001 Revision E Copyright 2009-2012 <strong>SafeNet</strong> Inc. 2