UKEPLE05-27<br />

Daikin air conditioners<br />

for shops, restaurants and offices<br />

4-way blow ceiling mounted cassette (600x600mm)<br />

www.daikin.co.uk<br />

<strong>FFQ</strong>-B7


The ceiling mounted 4-way blow cassette is specially designed for use in false ceilings.<br />

The greater part of the unit integrates perfectly with 600x600mm ceiling tiles. Only<br />

the slim decoration panel remains visible. As their name suggests, these units can<br />

discharge air in any of 4 directions.<br />

These cassettes are equipped with a special draught prevention and anti-ceiling<br />

soiling technology.<br />

COMFORT<br />

• You have the choice of 3 auto-swing positions for maximum comfort: standard, draught<br />

prevention or ceiling soiling prevention. Since the flaps can move to a 0° position, you<br />

will experience virtually no draught!<br />

Ceiling void<br />

is 295mm<br />

Ceiling void<br />

is 295mm<br />

Ceiling void<br />

is 295mm<br />

0°<br />

60°<br />

0°<br />

35°<br />

25°<br />

60°<br />

Standard setting:<br />

Auto swing between 0° to 60°<br />

Draught prevention:<br />

Auto swing between 0° and 35°<br />

Ceiling soiling prevention:<br />

Auto swing between 25° and 60°<br />

• You have the choice of 2 fan speeds to select: high or low. A high fan speed provides<br />

maximum reach while a low fan speed minimizes drafts.<br />

• The indoor unit is extremely quiet in operation. The sound levels are as low as 24.5dB (A),<br />

comparable to rustling leaves.<br />

• Daikin’s special dry programme reduces humidity in the room without variations in<br />

room temperature.<br />

• The indoor unit contains an air filter which removes microscopic particles and dust.


FLEXIBLE INSTALLATION AND EASY TO USE AND MAINTAIN<br />

• The indoor unit can easily be installed into false ceilings (minimum height of 295mm).<br />

• Due to the compact casing, it matches standard architectural modules of 600 x 600mm<br />

- ceiling tile cutting is no longer necessary.<br />

• When the ceiling void is too small, a panel spacer can be used to cover the space<br />

between the ceiling and decoration panel.<br />

• It is possible to shut one or 2 flaps off enabling the unit to be installed in the middle<br />

of the room, in a corner or in a small room.<br />

2-Way blow 3-Way blow 4-Way blow<br />

• Since the switch box is located within the unit, it is easy to access from below for<br />

maintenance without removing ceiling tiles.<br />

• The outdoor unit can be installed on a roof or terrace or placed against an outside wall.<br />

• Special anti-corrosion treatment of the outdoor unit’s heat exchanger fin, gives<br />

greater resistance against acid rain and salt corrosion. Additional resistance is provided<br />

by a rustproof steel sheet on the underside of the unit.<br />

An anti-corrosion heat<br />

exchanger cutaway view<br />

Heat exchanger<br />

Hydrophilic film<br />

Aluminium<br />

Corrosion-resistant<br />

Acrylic resin<br />

• Daikin remote controls give you easy control at your fingertips.<br />

• The wired remote control provides you with a schedule timer, enabling the air<br />

conditioning to be programmed daily or weekly.<br />

• The optional remote ON/OFF enables you to start/stop the air conditioning from a<br />

mobile phone via a telephone remote control (field supply).<br />

The optional forced OFF enables you switch off the unit automatically. E.g. when a<br />

window is opened, the unit switches off.<br />

Infrared remote<br />

control (Optional)<br />

Wired remote<br />

control (Optional)


ENERGY EFFICIENT<br />

• Energy label: up to class B<br />

• Inverter technology<br />

Improved energy efficiency:<br />

The use of integrated inverter control ensures maximum energy efficiency by supplying<br />

only the required heating or cooling load where a standard non inverter unit would supply<br />

maximum load in an on/off regime.<br />

Keeps temperature stable<br />

Slow start-up<br />

Smaller<br />

temperature<br />

difference<br />

Large temperature<br />

difference<br />

Set point<br />

Non inverter<br />

air conditioning<br />

Startup time reduced<br />

by about 1/3<br />

Repeats hot and cold cycles<br />

Inverter air conditioning<br />

Improved comfort:<br />

The rapid start up time provided by the inverter increases comfort by reducing the lead<br />

time in obtaining the required indoor temperature. As soon as the required temperature<br />

is reached, the inverter unit continuously scans the room for small changes and adjusts<br />

the room temperature in seconds, thereby increasing comfort once again.<br />

• The ‘home leave’ operation button prevents large temperature differences by<br />

continuously operating at a minimum (heating mode) or maximum (cooling mode) preset<br />

level while you’re out or sleeping. It also allows the indoor temperature to return quickly<br />

to your favourite comfort level.<br />

ONE PUSH<br />

While out of the home<br />

PUSH AGAIN<br />

When you go out push<br />

the “Home leave<br />

operation” button, and<br />

the air conditioner will<br />

adjust capacity to reach<br />

the preset temperature<br />

for “Home leave<br />

operation”.<br />

When you return, you<br />

will be welcomed by<br />

a comfortable<br />

air-conditioned room.<br />

Push the “Home leave<br />

operation” button again,<br />

and the air conditioner<br />

will adjust capacity to<br />

the set temperature for<br />

normal operation.<br />

APPLICATION OPTIONS<br />

• This model can be used for cooling only or heating.<br />

• It is possible to use the indoor unit in pair (connecting one indoor to one outdoor), twin,<br />

triple, double twin (connecting up to 4 indoors in the same room to a single outdoor)<br />

and multi applications (connecting up to 9 units in several rooms to 1 outdoor unit).


Capacity and power input<br />

COOLING ONLY - INVERTER CONTROLLED/NON INVERTER<br />

(air cooled)<br />

Cooling capacity min~nom~max kW<br />

Nominal input min~nom~max kW<br />

EER<br />

Energy label<br />

Annual energy consumption cooling kWh<br />

HEAT PUMP - INVERTER CONTROLLED<br />

(air cooled)<br />

Cooling capacity min~nom~max kW<br />

Heating capacity min~nom~max kW<br />

Nominal input cooling min~nom~max kW<br />

heating min~nom~max kW<br />

EER<br />

COP<br />

Energy label<br />

cooling<br />

heating<br />

Annual energy consumption cooling kWh<br />

<strong>FFQ</strong>25B7V1B <strong>FFQ</strong>35B7V1B <strong>FFQ</strong>50B7V1B <strong>FFQ</strong>60B7V1B <strong>FFQ</strong>50B7V1B <strong>FFQ</strong>60B7V1B<br />

RKS25DVMB RKS35DVMB RKS50BVMB9 RKS60BVMB9 RS50BVMB RS60BVMB<br />

1.3~2.5~3.0 1.4~3.4~3.7 0.90~4.70~5.60 0.90~5.80~6.00 4.70 (nom) 5.80 (nom)<br />

0.30~0.83~1.10 0.30~1.30~1.47 0.45~1.80~2.26 0.45~2.07~2.15 1.80 (nom) 2.07 (nom)<br />

3.01 2.62 2.61 2.80 2.61 2.80<br />

B D D D D D<br />

415 650 900 1,035 900 1,035<br />

<strong>FFQ</strong>25B7V1B <strong>FFQ</strong>35B7V1B <strong>FFQ</strong>50B7V1B <strong>FFQ</strong>60B7V1B<br />

RXS25DVMB RXS35DVMB RXS50BVMB RXS60BVMB<br />

1.3~2.5~3.0 1.4~3.4~3.7 0.90~4.70~5.60 0.90~5.80~6.00<br />

1.3~3.2~4.5 1.4~4.5~5.0 0.90~5.50~7.00 0.90~7.00~8.00<br />

0.30~0.83~1.10 0.30~1.30~1.47 0.45~1.80~2.26 0.45~2.07~2.15<br />

0.29~0.935~1.75 0.29~1.60~1.80 0.45~1.96~2.78 0.45~2.49~2.92<br />

3.01 2.62 2.61 2.80<br />

3.42 2.81 2.81 2.81<br />

B D D D<br />

B D D D<br />

415 650 900 1,035<br />

Notes:<br />

1) Energy label : scale from A (most efficient) to G (less efficient).<br />

2) The Energy Label Directive 2002/31/EC will enter into force once the relevant measurement standard will be published in the European Official Standard.<br />

3) Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions)<br />

MULTI - COOLING ONLY<br />

4MKS58D<br />

4MKS75D<br />

4MKS90D<br />

MULTI - HEAT PUMP<br />

2MXS52D*<br />

3MXS52D*<br />

4MXS68D*<br />

4MXS80D*<br />

SUPER MULTI PLUS<br />

RMXS112D*<br />

RMXS140D*<br />

RMXS160D*<br />

Max. n° Max. cooling Max. PI cooling<br />

of indoor units capacities (kW) (kW)<br />

4 6.60 2.47<br />

4 9.27 3.71<br />

4 9.86 3.52<br />

Max. n° Max. cooling Max. PI cooling Max. heating Max. PI heating<br />

of indoor units capacities (kW) (kW) capacities (kW) (kW)<br />

2 6.50 2.69 7.34 2.42<br />

3 6.50 2.69 7.34 2.42<br />

4 8.68 3.69 10.64 3.41<br />

4 9.49 3.34 11.00 3.52<br />

Max. n° Max. cooling Max. PI cooling Max. heating Max. PI heating<br />

of indoor units capacities (kW) (kW) capacities (kW) (kW)<br />

7 11.20 3.57 12.50 4.01<br />

8 14.00 5.23 16.00 5.31<br />

9 15.50 5.55 17.50 5.56<br />

Notes:<br />

- For more detailed information about specifications, capacities, power input, energy labelling and annual energy consumption, please refer to our Multi Model Catalogue/Super Multi Plus Catalogue or check<br />

with your local dealer.<br />

* At least 2 indoor units should be connected to a Multi outdoor unit.<br />

TWIN/TRIPLE/DOUBLE TWIN APPLICATION<br />

RR/RQ71<br />

RR/RQ100<br />

RR/RQ125<br />

RZQ71<br />

RZQ100<br />

RZQ125<br />

RZQ140<br />

RZQ200<br />

RZQ250<br />

<strong>FFQ</strong>35B7V1B <strong>FFQ</strong>50B7V1B <strong>FFQ</strong>60B7V1B<br />

2<br />

3 2<br />

3 2<br />

2<br />

3 2<br />

4 3 2<br />

4 3<br />

4 3<br />

4


Specifications indoor units<br />

COOLING ONLY/HEAT PUMP<br />

Dimensions HxWxD unit mm<br />

decoration panel mm<br />

Weight unit kg<br />

decoration panel kg<br />

Colour<br />

decoration panel<br />

<strong>Air</strong> flow rate H/L m 3 /min<br />

Fan speed<br />

Sound pressure level H/L dB(A)<br />

Sound power level H dB(A)<br />

Piping connections liquid mm<br />

gas<br />

mm<br />

drain (VP25) ID mm<br />

OD mm<br />

Heat insulation<br />

<strong>FFQ</strong>25B7V1B <strong>FFQ</strong>35B7V1B <strong>FFQ</strong>50B7V1B <strong>FFQ</strong>60B7V1B<br />

286x575x575<br />

55x700x700<br />

17.5<br />

2.7<br />

White (RAL9010)<br />

9/6.5 10/6.5 12/8 15/10<br />

2 steps<br />

29.5/24.5 32/25 36/27 41/32<br />

46.5 49 53 58<br />

ø6.4<br />

ø9.5 ø12.7<br />

ø20<br />

ø26<br />

Both liquid and gas pipes<br />

Indoor unit: <strong>FFQ</strong>-B<br />

<strong>FFQ</strong>25,35,50,60B7V1


Specifications outdoor units<br />

COOLING ONLY<br />

Dimensions HxWxD mm<br />

Weight<br />

kg<br />

Casing colour<br />

Sound pressure level H/L dB(A)<br />

Sound power level H dB(A)<br />

Compressor<br />

Refrigerant type<br />

Refrigerant charge<br />

kg/m<br />

Maximum piping length<br />

m<br />

Maximum level difference<br />

m<br />

Operation range from ~ to °CDB<br />

HEAT PUMP<br />

Dimensions HxWxD mm<br />

Weight<br />

kg<br />

Casing colour<br />

Sound pressure level cooling H/L dB(A)<br />

heating H/L dB(A)<br />

Sound power level cooling H dB(A)<br />

heating H dB(A)<br />

Compressor<br />

Refrigerant type<br />

Refrigerant charge<br />

kg/m<br />

Maximum piping length<br />

m<br />

Maximum level difference<br />

m<br />

Operation range cooling from ~ to °CDB<br />

heating from ~ to °CWB<br />

RKS25DVMB RKS35DVMB RKS50BVMB9 RKS60BVMB9 RS50BVMB RS60BVMB<br />

550x765x285 735x825x300 735x825x300<br />

30 32 49 53 49 53<br />

Ivory white<br />

Ivory white<br />

46/43 47/44 47/- 49/- 47/- 49/-<br />

61 62 63 64 63 64<br />

hermetically sealed swing type<br />

Swing compressor<br />

R-410A<br />

R-410A<br />

0.02 (for piping length exceeding 10m) 0.02 (piping length>10m)<br />

20 30 30<br />

15 20 20<br />

-10~46 -10(-15*)~46 +10~46<br />

RXS25DVMB RXS35DVMB RXS50BVMB RXS60BVMB<br />

550x765x285<br />

735x825x300<br />

30 32 49 53<br />

Ivory white<br />

46/43 47/44 47/- 49/-<br />

47/44 48/45 48/- 49/-<br />

61 62 63 64<br />

62 63 64 64<br />

hermetically sealed swing type<br />

R-410A<br />

0.02 (for piping length exceeding 10m)<br />

20 30<br />

15 20<br />

-10~46<br />

-15~20<br />

* Possibility to extend the operation range down to -15°C by turning ON the switch on the outdoor unit PCB. In this case, the unit will stop operation at -20°C or lower and will recover when temperature rises again.<br />

- Information is not available.


Accessories: control systems<br />

INDOOR UNITS <strong>FFQ</strong>25B <strong>FFQ</strong>35B <strong>FFQ</strong>50B <strong>FFQ</strong>60B<br />

Wired remote control<br />

BRC1D527<br />

Infrared remote control cooling only BRC7E531W7<br />

heat pump<br />

BRC7E530W7<br />

Centralised remote control<br />

DCS302C51<br />

Unified ON/OFF control<br />

DCS301B51<br />

Schedule timer<br />

DST301B51<br />

Adapter for wiring (1)<br />

KRP1B57<br />

Adapter for external ON/OFF and monitoring (1)<br />

KRP4A53<br />

Adapter for wiring (hour meter) (2)<br />

EKRP1B2<br />

Remote sensor<br />

KRCS01-1<br />

Installation box for adapter PCB<br />

KRP1B101<br />

Interface adapter for Sky <strong>Air</strong><br />

DTA112B51<br />

Remote ON/OFF, forced OFF<br />

EKRORO<br />

(1) Installation box for adapter PCB (KRP1B101) is necessary.<br />

(2) Possibility to connect an hour meter (field supply). This part should not be installed inside the equipment.<br />

Accessories<br />

INDOOR UNITS <strong>FFQ</strong>25B <strong>FFQ</strong>35B <strong>FFQ</strong>50B <strong>FFQ</strong>60B<br />

Decoration panel<br />

BYFQ60B7W1<br />

long-life filter<br />

KAFQ441B60<br />

Fresh air intake kit direct installation type KDDQ44X60<br />

Sealing member of air discharge outlet<br />

KDBHQ44B60<br />

Panel spacer<br />

KDBQ44B60<br />

Accessories<br />

OUTDOOR UNITS<br />

<strong>Air</strong> direction adjustment grille<br />

Central drain plug<br />

RKS/RXS25D RKS/RXS35D RS/RKS/RXS50B RS/RKS/RXS60B<br />

KRW937A4<br />

KPW945A4<br />

KKP937A4 - -<br />

Notes:<br />

1) V1 = 1~,230V,50Hz; VM = 1~, 220-240V/220-230V, 50Hz/60Hz; V3 = 1~, 230V, 50Hz<br />

2) Nominal cooling capacities are based on: indoor temperature 27°CDB/19°CWB • outdoor temperature 35°CDB • refrigerant piping length 7.5m • level difference 0m.<br />

3) Nominal heating capacities are based on: indoor temperature 20°CDB • outdoor temperature 7°CDB/6°CWB • refrigerant piping length 7.5m • level difference 0m.<br />

4) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.<br />

5) Units should be selected on nominal capacity. Max. capacity is limited to peak periods.<br />

6) The sound pressure level is measured at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment.<br />

7) The sound power level is an absolute value indicating the "power" which a sound source generates.<br />

Daikin’s unique position as a manufacturer<br />

of air conditioning equipment, compressors<br />

and refrigerants has led to its close<br />

involvement in environmental issues. For<br />

several years Daikin has had the intention to<br />

become a leader in the provision of<br />

environmental friendly products. This<br />

challenge demands the eco design and<br />

development of a wide range of products<br />

and an energy management system; which<br />

involves energy conservation and reduction<br />

of waste.<br />

Daikin Europe N.V. is approved by LRQA for its<br />

Quality Management System in accordance with<br />

the ISO9001 standard.<br />

ISO9001 pertains to quality assurance regarding<br />

design, development, manufacturing as well as to<br />

services related to the product.<br />

ISO14001 assures an effective environmental<br />

management system in order to help protect human<br />

health and the environment from the potential<br />

impact of our activities, products and services and<br />

to assist in maintaining and improving the quality<br />

of the environment.<br />

Daikin units comply with the European regulations<br />

that guarantee the safety of the product.<br />

Daikin Europe N.V. is participating in the EUROVENT<br />

Certification Programme. Products are as listed in<br />

the EUROVENT Directory of Certified Products.<br />

Multi units are Eurovent certified for combinations<br />

up to 2 indoor units.<br />

Specifications are subject to change without prior notice.<br />

Daikin products are distributed by:<br />

UKEPLE05-27 / 08/05 / Printed in the UK by Portishead Press<br />

Printed on elemental chlorine free paper

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!