UKEPLE05-27<br />
Daikin air conditioners<br />
for shops, restaurants and offices<br />
4-way blow ceiling mounted cassette (600x600mm)<br />
www.daikin.co.uk<br />
<strong>FFQ</strong>-B7
The ceiling mounted 4-way blow cassette is specially designed for use in false ceilings.<br />
The greater part of the unit integrates perfectly with 600x600mm ceiling tiles. Only<br />
the slim decoration panel remains visible. As their name suggests, these units can<br />
discharge air in any of 4 directions.<br />
These cassettes are equipped with a special draught prevention and anti-ceiling<br />
soiling technology.<br />
COMFORT<br />
• You have the choice of 3 auto-swing positions for maximum comfort: standard, draught<br />
prevention or ceiling soiling prevention. Since the flaps can move to a 0° position, you<br />
will experience virtually no draught!<br />
Ceiling void<br />
is 295mm<br />
Ceiling void<br />
is 295mm<br />
Ceiling void<br />
is 295mm<br />
0°<br />
60°<br />
0°<br />
35°<br />
25°<br />
60°<br />
Standard setting:<br />
Auto swing between 0° to 60°<br />
Draught prevention:<br />
Auto swing between 0° and 35°<br />
Ceiling soiling prevention:<br />
Auto swing between 25° and 60°<br />
• You have the choice of 2 fan speeds to select: high or low. A high fan speed provides<br />
maximum reach while a low fan speed minimizes drafts.<br />
• The indoor unit is extremely quiet in operation. The sound levels are as low as 24.5dB (A),<br />
comparable to rustling leaves.<br />
• Daikin’s special dry programme reduces humidity in the room without variations in<br />
room temperature.<br />
• The indoor unit contains an air filter which removes microscopic particles and dust.
FLEXIBLE INSTALLATION AND EASY TO USE AND MAINTAIN<br />
• The indoor unit can easily be installed into false ceilings (minimum height of 295mm).<br />
• Due to the compact casing, it matches standard architectural modules of 600 x 600mm<br />
- ceiling tile cutting is no longer necessary.<br />
• When the ceiling void is too small, a panel spacer can be used to cover the space<br />
between the ceiling and decoration panel.<br />
• It is possible to shut one or 2 flaps off enabling the unit to be installed in the middle<br />
of the room, in a corner or in a small room.<br />
2-Way blow 3-Way blow 4-Way blow<br />
• Since the switch box is located within the unit, it is easy to access from below for<br />
maintenance without removing ceiling tiles.<br />
• The outdoor unit can be installed on a roof or terrace or placed against an outside wall.<br />
• Special anti-corrosion treatment of the outdoor unit’s heat exchanger fin, gives<br />
greater resistance against acid rain and salt corrosion. Additional resistance is provided<br />
by a rustproof steel sheet on the underside of the unit.<br />
An anti-corrosion heat<br />
exchanger cutaway view<br />
Heat exchanger<br />
Hydrophilic film<br />
Aluminium<br />
Corrosion-resistant<br />
Acrylic resin<br />
• Daikin remote controls give you easy control at your fingertips.<br />
• The wired remote control provides you with a schedule timer, enabling the air<br />
conditioning to be programmed daily or weekly.<br />
• The optional remote ON/OFF enables you to start/stop the air conditioning from a<br />
mobile phone via a telephone remote control (field supply).<br />
The optional forced OFF enables you switch off the unit automatically. E.g. when a<br />
window is opened, the unit switches off.<br />
Infrared remote<br />
control (Optional)<br />
Wired remote<br />
control (Optional)
ENERGY EFFICIENT<br />
• Energy label: up to class B<br />
• Inverter technology<br />
Improved energy efficiency:<br />
The use of integrated inverter control ensures maximum energy efficiency by supplying<br />
only the required heating or cooling load where a standard non inverter unit would supply<br />
maximum load in an on/off regime.<br />
Keeps temperature stable<br />
Slow start-up<br />
Smaller<br />
temperature<br />
difference<br />
Large temperature<br />
difference<br />
Set point<br />
Non inverter<br />
air conditioning<br />
Startup time reduced<br />
by about 1/3<br />
Repeats hot and cold cycles<br />
Inverter air conditioning<br />
Improved comfort:<br />
The rapid start up time provided by the inverter increases comfort by reducing the lead<br />
time in obtaining the required indoor temperature. As soon as the required temperature<br />
is reached, the inverter unit continuously scans the room for small changes and adjusts<br />
the room temperature in seconds, thereby increasing comfort once again.<br />
• The ‘home leave’ operation button prevents large temperature differences by<br />
continuously operating at a minimum (heating mode) or maximum (cooling mode) preset<br />
level while you’re out or sleeping. It also allows the indoor temperature to return quickly<br />
to your favourite comfort level.<br />
ONE PUSH<br />
While out of the home<br />
PUSH AGAIN<br />
When you go out push<br />
the “Home leave<br />
operation” button, and<br />
the air conditioner will<br />
adjust capacity to reach<br />
the preset temperature<br />
for “Home leave<br />
operation”.<br />
When you return, you<br />
will be welcomed by<br />
a comfortable<br />
air-conditioned room.<br />
Push the “Home leave<br />
operation” button again,<br />
and the air conditioner<br />
will adjust capacity to<br />
the set temperature for<br />
normal operation.<br />
APPLICATION OPTIONS<br />
• This model can be used for cooling only or heating.<br />
• It is possible to use the indoor unit in pair (connecting one indoor to one outdoor), twin,<br />
triple, double twin (connecting up to 4 indoors in the same room to a single outdoor)<br />
and multi applications (connecting up to 9 units in several rooms to 1 outdoor unit).
Capacity and power input<br />
COOLING ONLY - INVERTER CONTROLLED/NON INVERTER<br />
(air cooled)<br />
Cooling capacity min~nom~max kW<br />
Nominal input min~nom~max kW<br />
EER<br />
Energy label<br />
Annual energy consumption cooling kWh<br />
HEAT PUMP - INVERTER CONTROLLED<br />
(air cooled)<br />
Cooling capacity min~nom~max kW<br />
Heating capacity min~nom~max kW<br />
Nominal input cooling min~nom~max kW<br />
heating min~nom~max kW<br />
EER<br />
COP<br />
Energy label<br />
cooling<br />
heating<br />
Annual energy consumption cooling kWh<br />
<strong>FFQ</strong>25B7V1B <strong>FFQ</strong>35B7V1B <strong>FFQ</strong>50B7V1B <strong>FFQ</strong>60B7V1B <strong>FFQ</strong>50B7V1B <strong>FFQ</strong>60B7V1B<br />
RKS25DVMB RKS35DVMB RKS50BVMB9 RKS60BVMB9 RS50BVMB RS60BVMB<br />
1.3~2.5~3.0 1.4~3.4~3.7 0.90~4.70~5.60 0.90~5.80~6.00 4.70 (nom) 5.80 (nom)<br />
0.30~0.83~1.10 0.30~1.30~1.47 0.45~1.80~2.26 0.45~2.07~2.15 1.80 (nom) 2.07 (nom)<br />
3.01 2.62 2.61 2.80 2.61 2.80<br />
B D D D D D<br />
415 650 900 1,035 900 1,035<br />
<strong>FFQ</strong>25B7V1B <strong>FFQ</strong>35B7V1B <strong>FFQ</strong>50B7V1B <strong>FFQ</strong>60B7V1B<br />
RXS25DVMB RXS35DVMB RXS50BVMB RXS60BVMB<br />
1.3~2.5~3.0 1.4~3.4~3.7 0.90~4.70~5.60 0.90~5.80~6.00<br />
1.3~3.2~4.5 1.4~4.5~5.0 0.90~5.50~7.00 0.90~7.00~8.00<br />
0.30~0.83~1.10 0.30~1.30~1.47 0.45~1.80~2.26 0.45~2.07~2.15<br />
0.29~0.935~1.75 0.29~1.60~1.80 0.45~1.96~2.78 0.45~2.49~2.92<br />
3.01 2.62 2.61 2.80<br />
3.42 2.81 2.81 2.81<br />
B D D D<br />
B D D D<br />
415 650 900 1,035<br />
Notes:<br />
1) Energy label : scale from A (most efficient) to G (less efficient).<br />
2) The Energy Label Directive 2002/31/EC will enter into force once the relevant measurement standard will be published in the European Official Standard.<br />
3) Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions)<br />
MULTI - COOLING ONLY<br />
4MKS58D<br />
4MKS75D<br />
4MKS90D<br />
MULTI - HEAT PUMP<br />
2MXS52D*<br />
3MXS52D*<br />
4MXS68D*<br />
4MXS80D*<br />
SUPER MULTI PLUS<br />
RMXS112D*<br />
RMXS140D*<br />
RMXS160D*<br />
Max. n° Max. cooling Max. PI cooling<br />
of indoor units capacities (kW) (kW)<br />
4 6.60 2.47<br />
4 9.27 3.71<br />
4 9.86 3.52<br />
Max. n° Max. cooling Max. PI cooling Max. heating Max. PI heating<br />
of indoor units capacities (kW) (kW) capacities (kW) (kW)<br />
2 6.50 2.69 7.34 2.42<br />
3 6.50 2.69 7.34 2.42<br />
4 8.68 3.69 10.64 3.41<br />
4 9.49 3.34 11.00 3.52<br />
Max. n° Max. cooling Max. PI cooling Max. heating Max. PI heating<br />
of indoor units capacities (kW) (kW) capacities (kW) (kW)<br />
7 11.20 3.57 12.50 4.01<br />
8 14.00 5.23 16.00 5.31<br />
9 15.50 5.55 17.50 5.56<br />
Notes:<br />
- For more detailed information about specifications, capacities, power input, energy labelling and annual energy consumption, please refer to our Multi Model Catalogue/Super Multi Plus Catalogue or check<br />
with your local dealer.<br />
* At least 2 indoor units should be connected to a Multi outdoor unit.<br />
TWIN/TRIPLE/DOUBLE TWIN APPLICATION<br />
RR/RQ71<br />
RR/RQ100<br />
RR/RQ125<br />
RZQ71<br />
RZQ100<br />
RZQ125<br />
RZQ140<br />
RZQ200<br />
RZQ250<br />
<strong>FFQ</strong>35B7V1B <strong>FFQ</strong>50B7V1B <strong>FFQ</strong>60B7V1B<br />
2<br />
3 2<br />
3 2<br />
2<br />
3 2<br />
4 3 2<br />
4 3<br />
4 3<br />
4
Specifications indoor units<br />
COOLING ONLY/HEAT PUMP<br />
Dimensions HxWxD unit mm<br />
decoration panel mm<br />
Weight unit kg<br />
decoration panel kg<br />
Colour<br />
decoration panel<br />
<strong>Air</strong> flow rate H/L m 3 /min<br />
Fan speed<br />
Sound pressure level H/L dB(A)<br />
Sound power level H dB(A)<br />
Piping connections liquid mm<br />
gas<br />
mm<br />
drain (VP25) ID mm<br />
OD mm<br />
Heat insulation<br />
<strong>FFQ</strong>25B7V1B <strong>FFQ</strong>35B7V1B <strong>FFQ</strong>50B7V1B <strong>FFQ</strong>60B7V1B<br />
286x575x575<br />
55x700x700<br />
17.5<br />
2.7<br />
White (RAL9010)<br />
9/6.5 10/6.5 12/8 15/10<br />
2 steps<br />
29.5/24.5 32/25 36/27 41/32<br />
46.5 49 53 58<br />
ø6.4<br />
ø9.5 ø12.7<br />
ø20<br />
ø26<br />
Both liquid and gas pipes<br />
Indoor unit: <strong>FFQ</strong>-B<br />
<strong>FFQ</strong>25,35,50,60B7V1
Specifications outdoor units<br />
COOLING ONLY<br />
Dimensions HxWxD mm<br />
Weight<br />
kg<br />
Casing colour<br />
Sound pressure level H/L dB(A)<br />
Sound power level H dB(A)<br />
Compressor<br />
Refrigerant type<br />
Refrigerant charge<br />
kg/m<br />
Maximum piping length<br />
m<br />
Maximum level difference<br />
m<br />
Operation range from ~ to °CDB<br />
HEAT PUMP<br />
Dimensions HxWxD mm<br />
Weight<br />
kg<br />
Casing colour<br />
Sound pressure level cooling H/L dB(A)<br />
heating H/L dB(A)<br />
Sound power level cooling H dB(A)<br />
heating H dB(A)<br />
Compressor<br />
Refrigerant type<br />
Refrigerant charge<br />
kg/m<br />
Maximum piping length<br />
m<br />
Maximum level difference<br />
m<br />
Operation range cooling from ~ to °CDB<br />
heating from ~ to °CWB<br />
RKS25DVMB RKS35DVMB RKS50BVMB9 RKS60BVMB9 RS50BVMB RS60BVMB<br />
550x765x285 735x825x300 735x825x300<br />
30 32 49 53 49 53<br />
Ivory white<br />
Ivory white<br />
46/43 47/44 47/- 49/- 47/- 49/-<br />
61 62 63 64 63 64<br />
hermetically sealed swing type<br />
Swing compressor<br />
R-410A<br />
R-410A<br />
0.02 (for piping length exceeding 10m) 0.02 (piping length>10m)<br />
20 30 30<br />
15 20 20<br />
-10~46 -10(-15*)~46 +10~46<br />
RXS25DVMB RXS35DVMB RXS50BVMB RXS60BVMB<br />
550x765x285<br />
735x825x300<br />
30 32 49 53<br />
Ivory white<br />
46/43 47/44 47/- 49/-<br />
47/44 48/45 48/- 49/-<br />
61 62 63 64<br />
62 63 64 64<br />
hermetically sealed swing type<br />
R-410A<br />
0.02 (for piping length exceeding 10m)<br />
20 30<br />
15 20<br />
-10~46<br />
-15~20<br />
* Possibility to extend the operation range down to -15°C by turning ON the switch on the outdoor unit PCB. In this case, the unit will stop operation at -20°C or lower and will recover when temperature rises again.<br />
- Information is not available.
Accessories: control systems<br />
INDOOR UNITS <strong>FFQ</strong>25B <strong>FFQ</strong>35B <strong>FFQ</strong>50B <strong>FFQ</strong>60B<br />
Wired remote control<br />
BRC1D527<br />
Infrared remote control cooling only BRC7E531W7<br />
heat pump<br />
BRC7E530W7<br />
Centralised remote control<br />
DCS302C51<br />
Unified ON/OFF control<br />
DCS301B51<br />
Schedule timer<br />
DST301B51<br />
Adapter for wiring (1)<br />
KRP1B57<br />
Adapter for external ON/OFF and monitoring (1)<br />
KRP4A53<br />
Adapter for wiring (hour meter) (2)<br />
EKRP1B2<br />
Remote sensor<br />
KRCS01-1<br />
Installation box for adapter PCB<br />
KRP1B101<br />
Interface adapter for Sky <strong>Air</strong><br />
DTA112B51<br />
Remote ON/OFF, forced OFF<br />
EKRORO<br />
(1) Installation box for adapter PCB (KRP1B101) is necessary.<br />
(2) Possibility to connect an hour meter (field supply). This part should not be installed inside the equipment.<br />
Accessories<br />
INDOOR UNITS <strong>FFQ</strong>25B <strong>FFQ</strong>35B <strong>FFQ</strong>50B <strong>FFQ</strong>60B<br />
Decoration panel<br />
BYFQ60B7W1<br />
long-life filter<br />
KAFQ441B60<br />
Fresh air intake kit direct installation type KDDQ44X60<br />
Sealing member of air discharge outlet<br />
KDBHQ44B60<br />
Panel spacer<br />
KDBQ44B60<br />
Accessories<br />
OUTDOOR UNITS<br />
<strong>Air</strong> direction adjustment grille<br />
Central drain plug<br />
RKS/RXS25D RKS/RXS35D RS/RKS/RXS50B RS/RKS/RXS60B<br />
KRW937A4<br />
KPW945A4<br />
KKP937A4 - -<br />
Notes:<br />
1) V1 = 1~,230V,50Hz; VM = 1~, 220-240V/220-230V, 50Hz/60Hz; V3 = 1~, 230V, 50Hz<br />
2) Nominal cooling capacities are based on: indoor temperature 27°CDB/19°CWB • outdoor temperature 35°CDB • refrigerant piping length 7.5m • level difference 0m.<br />
3) Nominal heating capacities are based on: indoor temperature 20°CDB • outdoor temperature 7°CDB/6°CWB • refrigerant piping length 7.5m • level difference 0m.<br />
4) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.<br />
5) Units should be selected on nominal capacity. Max. capacity is limited to peak periods.<br />
6) The sound pressure level is measured at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment.<br />
7) The sound power level is an absolute value indicating the "power" which a sound source generates.<br />
Daikin’s unique position as a manufacturer<br />
of air conditioning equipment, compressors<br />
and refrigerants has led to its close<br />
involvement in environmental issues. For<br />
several years Daikin has had the intention to<br />
become a leader in the provision of<br />
environmental friendly products. This<br />
challenge demands the eco design and<br />
development of a wide range of products<br />
and an energy management system; which<br />
involves energy conservation and reduction<br />
of waste.<br />
Daikin Europe N.V. is approved by LRQA for its<br />
Quality Management System in accordance with<br />
the ISO9001 standard.<br />
ISO9001 pertains to quality assurance regarding<br />
design, development, manufacturing as well as to<br />
services related to the product.<br />
ISO14001 assures an effective environmental<br />
management system in order to help protect human<br />
health and the environment from the potential<br />
impact of our activities, products and services and<br />
to assist in maintaining and improving the quality<br />
of the environment.<br />
Daikin units comply with the European regulations<br />
that guarantee the safety of the product.<br />
Daikin Europe N.V. is participating in the EUROVENT<br />
Certification Programme. Products are as listed in<br />
the EUROVENT Directory of Certified Products.<br />
Multi units are Eurovent certified for combinations<br />
up to 2 indoor units.<br />
Specifications are subject to change without prior notice.<br />
Daikin products are distributed by:<br />
UKEPLE05-27 / 08/05 / Printed in the UK by Portishead Press<br />
Printed on elemental chlorine free paper