Heat pumps |<br />

PRODUCT ADVANTAGES AGES<br />

Single-unit system “ready to operate”.<br />

Variable-speed compressor to always provide power to match the<br />

demand.<br />

“Gentle” starting without inrush current, even on networks with<br />

undervoltage.<br />

High-performance exchanger with counter-current exchange.<br />

Specially dedicated for the heating mode.<br />

“Blue Fin” hydrophilic coating of the exchanger for quick defrosting.<br />

Operation according to a water programme for high annual COP.<br />

Tested adjustments, known to all professionals.<br />

High accessibility for maintenance operation.<br />

Low noise levels.<br />

42<br />

<strong>Aqu@Scop</strong> <strong>Advance</strong><br />

<strong>DCI</strong><br />

AIR/WATER RESIDENTIAL HEAT PUMP<br />

Ideal for new construction.<br />

Management of domestic hot water.<br />

Double zone.<br />

Water outlet temperature up to 55°C.<br />

Operation with outdoor temperatures as<br />

low as -15°C.<br />

Ideal for operation on heating floors,<br />

low-temperature radiators,<br />

fan coil units.<br />

3.9 to 14.9 kW of heating over 3 models.<br />

Built-in 6 kW electric heater (2 stages).<br />

Built-in expansion vessel.<br />

Built-in circulator pump.<br />

Backup starting switch.<br />

Water flow controller as standard.<br />

Water filter (supplied, not installed).<br />

HEATING MODE<br />

HIGH TEMPERATURE<br />

UP TO 55°C<br />

WATER<br />

PROGRAMME<br />

ACCESSORIES/OPTIONS<br />

Accessories Part number<br />

Shut-off valve with pressure tap 7ACFH0423<br />

1” hose kit, length 1 m 7ACFH0422<br />

Decanting �lter (sludge pot) 7ACFH0666<br />

Three-way valve alone for domestic hot water management or boiler backup 7ACFH0543<br />

300-litre domestic hot water tank kit 7ACFH0662<br />

"Plate exchanger & circulator pump" kit for domestic hot water, top outlet<br />

(sensor supplied for installation in a thimble)<br />

7ACFH0789<br />

"Plate exchanger & circulator pump" kit for domestic hot water, bottom outlet<br />

(sensor supplied and installed)<br />

7ACFH0801<br />

Hydraulic connection kit with three-way valve 7ACFH0490<br />

Hydraulic connection kit without three-way valve 7ACFH0491<br />

140-litre buffer tank / mixing tank 7ACFH0663<br />

Remote wireless ambient sensor 7ACEL1593<br />

Dual-zone kit for radiators and �oor (3-way valve + thermostat) 7ACFH0808<br />

Wired programmable and communicating ambient thermostat 7ACEL1592<br />

Shock-absorbing support feet 7ACTL0472<br />

Water �lter (supplied, not installed) STD<br />

Water �ow controller STD<br />

R410A<br />

R410A FLUID<br />

HEATING/<br />

COOLING<br />

FLOOR<br />

HEATING/COOLING<br />

FLOOR<br />

PRODUCT DEVELOPED<br />

AND MANUFACTURED<br />

IN FRANCE<br />

DC INVERTER<br />

LOW<br />

TEMPERATURE<br />

HEATER<br />

LOW-TEMPERATURE<br />

RADIATOR<br />

CE STANDARD<br />

-<br />

OUTDOOR<br />

OPERATING LIMITS<br />

IN HEATING MODE<br />

BI-ZONE<br />

°C


7ACEL1592<br />

7ACFH0662<br />

7ACFH0543<br />

7ACFH0491 (alone)<br />

7ACFH0490 (kit)<br />

7ACFH0666<br />

BACKUP STARTING SWITCH<br />

This switch can be used to switch manually from priority heating<br />

of the compressor to additional heating.<br />

Wired ambient thermostat<br />

- Adjustment of ambient temperature<br />

- Daily or weekly programming<br />

- Holiday programming, no-frost mode<br />

MAIN OPTIONS AND ACCESSORIES<br />

43<br />

7ACEL1593<br />

300-litre domestic hot water tank<br />

(and 2.5 kW of electrical resistance heaters)<br />

optimised with the operation of the <strong>Aqu@Scop</strong> HT<br />

- Three authorisation modes<br />

- Holiday mode<br />

- Programmable anti-legionella function<br />

- Management of the three-way valve / circulator pump couple<br />

- 3.1m 2 exchange surface 7ACFH0663<br />

ON/OFF three-way valve<br />

Required for optional production of domestic hot water.<br />

Directs the produced hot water either towards the heating<br />

circuit or towards the domestic hot water tank. A second<br />

three-way valve is recommended for boiler-backup<br />

installation.<br />

Hydraulic kit<br />

For connecting to the boiler, available alone or in a<br />

complete kit with the three-way valve.<br />

Made up of a set of assembled pipes and valves,<br />

a set of connectors with spherical-conical seat.<br />

Decanting pot (sludge pot)<br />

Effectively separates the impurities from the heating<br />

circuit and collects them in a decanting chamber, where<br />

they can be bled off, even while the installation<br />

is operational.<br />

7ACFH0789<br />

(top outlet)<br />

7ACEL1801<br />

(bottom outlet)<br />

7ACTL0472<br />

Wireless thermostat with radio communication<br />

Sends the measured ambient temperature.<br />

140-litre buffer tank / mixing tank<br />

Necessary when the volume of water in the installation is<br />

insuf�cient. It protects the heat pump against short cycles<br />

that can reduce the useful life of the compressors and<br />

improves operation during defrosting phases.<br />

Domestic hot water kit<br />

Required when replacing existing installations.<br />

This kit, made up of a plate exchanger and a circulator<br />

pump, enables the production of domestic hot water<br />

using existing tanks (electric cumulus).<br />

Top outlet: sensor installed on the top outlet of the tank.<br />

If not possible, bottom outlet: sensor installed on the kit.<br />

Shock-absorbing support feet<br />

Raise the heat pump by 10cm, allow the evacuation of<br />

condensates and defrosting water.<br />

Their rubber design provides excellent shock absorption<br />

against the transmission of vibrations through solids.


Heat pumps |<br />

OPERATING LIMITS<br />

WATER CIRCULATOR PUMP PRESSURE FLOW CURVES<br />

ADVANCE 006 ADVANCE 012<br />

Available pressure<br />

kPa Bar<br />

60 0.6<br />

50 0.5<br />

40 0.4<br />

30 0.3<br />

20 0.2<br />

10 0.1<br />

0<br />

ADVANCE 016<br />

Available pressure<br />

0<br />

RESPECT FOR THE ENVIRONMENT WITH UP TO 80% LESS CO2 EMISSIONS<br />

The <strong><strong>Air</strong>well</strong> <strong>Aqu@Scop</strong> is a heating solution that makes the most of natural energy sources<br />

R410A<br />

800<br />

kPa bar<br />

60 0.6<br />

50 0.5<br />

40 0.4<br />

30 0.3<br />

20 0.2<br />

10 0.1<br />

0<br />

Water starting temperature (°C)<br />

Nominal flow<br />

rate<br />

HS<br />

MS<br />

LS<br />

70<br />

65<br />

60<br />

55<br />

50<br />

45<br />

40<br />

35<br />

30<br />

25<br />

20<br />

<strong>Aqu@Scop</strong><br />

<strong>Advance</strong><br />

while respecting the environment. It operates in a closed circuit and uses “green” R410A fluid<br />

which helps save the ozone layer.<br />

<strong>Aqu@Scop</strong> <strong>Advance</strong>-R<br />

-25 -20 -15 -10 -5 0 5 10 15 20<br />

1000 1200 1400 1600 1800 2000<br />

Water flow rate (l/h)<br />

HS<br />

Nominal flow<br />

rate<br />

0<br />

1300 1500 1700 1900 2100 2300 2500 2700 2900<br />

Water flow rate (l/h)<br />

Outside air temperature (°C)<br />

44<br />

Available pressure<br />

kPa Bar<br />

60 0.6<br />

50 0.5<br />

40 0.4<br />

30 0.3<br />

20 0.2<br />

10 0.1<br />

0<br />

0<br />

800<br />

25<br />

Nominal flow<br />

rate<br />

HS<br />

MS<br />

LS<br />

1000 1200 1400 1600 1800 2000<br />

Water flow rate (l/h)


AQU@SCOP @SCOP ADV ADVANCE<br />

TECHNICAL DAT ATA Heating floor application<br />

OUTDOOR AIR<br />

REGIME 7°C<br />

OUTDOOR AIR<br />

REGIME 2°C<br />

OUTDOOR AIR<br />

REGIME -7°C<br />

Application to radiators / fan coil units<br />

OUTDOOR AIR<br />

REGIME 7°C<br />

OUTDOOR AIR<br />

REGIME 2°C<br />

OUTDOOR AIR<br />

REGIME -7°C<br />

AIRWELL SOLUTIONS<br />

45<br />

ADV 006 ADV 012 ADV 016<br />

Floor heating power / water regime 30/35°C kW 6.62 (3.9 to 8.8) 10.76 (5.68 to 12.95) 15.47 (7.66 to 19.08)<br />

COP* 4.19 4.03 4.16<br />

Floor heating power / water outlet 35°C kW 4.96 8.56 11.77<br />

COP* 3.15 3.24 3.28<br />

Floor heating power / water outlet 35°C kW 3.7 6.9 9.01<br />

COP* 2.44 2.6 2.51<br />

Radiator heating power / water outlet 45°C kW 8.72 12.43 16.87<br />

COP* 3 2.82 3<br />

Radiator heating power / water outlet 45°C kW 6.6 10.33 13.41<br />

COP* 2.48 2.38 2.5<br />

Radiator heating power / water outlet 45°C kW 5.3 8.1 10.11<br />

COP* 2.04 1.9 2.01<br />

GROUPE Sound power dB(A) 63.5 65 65.5<br />

POWER SUPPLY<br />

1~230V-50Hz<br />

* COP values with defrosting.<br />

** According to application conditions.<br />

Sound pressure at 5 m in free �eld dB(A) 41.5 43 43.5<br />

Compressor type Inverter Rotary Scroll Scroll<br />

R410A �uid Kg 2 2.9 3.6<br />

Dimensions (WxDxH) mm 1232x401x905 1232x401x1307 1232x401x1307<br />

Weight Kg 125 175 185<br />

Outdoor temperature operating limits** °C -15 -15 -15<br />

Water outlet temperatures (mini/maxi) °C 25/55<br />

Exchanger type Plates<br />

Water intake/outlet connections inches 1” Female<br />

Expansion vessel l 3 5 5<br />

Electric backup (2 stages) kW 6(2+4) 6(2+4) 6(2+4)<br />

Power cable mm 2 3x10 3x16 3x16<br />

Protection rating A 40 63 63