Heat pumps |<br />
PRODUCT ADVANTAGES AGES<br />
Single-unit system “ready to operate”.<br />
Variable-speed compressor to always provide power to match the<br />
demand.<br />
“Gentle” starting without inrush current, even on networks with<br />
undervoltage.<br />
High-performance exchanger with counter-current exchange.<br />
Specially dedicated for the heating mode.<br />
“Blue Fin” hydrophilic coating of the exchanger for quick defrosting.<br />
Operation according to a water programme for high annual COP.<br />
Tested adjustments, known to all professionals.<br />
High accessibility for maintenance operation.<br />
Low noise levels.<br />
42<br />
<strong>Aqu@Scop</strong> <strong>Advance</strong><br />
<strong>DCI</strong><br />
AIR/WATER RESIDENTIAL HEAT PUMP<br />
Ideal for new construction.<br />
Management of domestic hot water.<br />
Double zone.<br />
Water outlet temperature up to 55°C.<br />
Operation with outdoor temperatures as<br />
low as -15°C.<br />
Ideal for operation on heating floors,<br />
low-temperature radiators,<br />
fan coil units.<br />
3.9 to 14.9 kW of heating over 3 models.<br />
Built-in 6 kW electric heater (2 stages).<br />
Built-in expansion vessel.<br />
Built-in circulator pump.<br />
Backup starting switch.<br />
Water flow controller as standard.<br />
Water filter (supplied, not installed).<br />
HEATING MODE<br />
HIGH TEMPERATURE<br />
UP TO 55°C<br />
WATER<br />
PROGRAMME<br />
ACCESSORIES/OPTIONS<br />
Accessories Part number<br />
Shut-off valve with pressure tap 7ACFH0423<br />
1” hose kit, length 1 m 7ACFH0422<br />
Decanting �lter (sludge pot) 7ACFH0666<br />
Three-way valve alone for domestic hot water management or boiler backup 7ACFH0543<br />
300-litre domestic hot water tank kit 7ACFH0662<br />
"Plate exchanger & circulator pump" kit for domestic hot water, top outlet<br />
(sensor supplied for installation in a thimble)<br />
7ACFH0789<br />
"Plate exchanger & circulator pump" kit for domestic hot water, bottom outlet<br />
(sensor supplied and installed)<br />
7ACFH0801<br />
Hydraulic connection kit with three-way valve 7ACFH0490<br />
Hydraulic connection kit without three-way valve 7ACFH0491<br />
140-litre buffer tank / mixing tank 7ACFH0663<br />
Remote wireless ambient sensor 7ACEL1593<br />
Dual-zone kit for radiators and �oor (3-way valve + thermostat) 7ACFH0808<br />
Wired programmable and communicating ambient thermostat 7ACEL1592<br />
Shock-absorbing support feet 7ACTL0472<br />
Water �lter (supplied, not installed) STD<br />
Water �ow controller STD<br />
R410A<br />
R410A FLUID<br />
HEATING/<br />
COOLING<br />
FLOOR<br />
HEATING/COOLING<br />
FLOOR<br />
PRODUCT DEVELOPED<br />
AND MANUFACTURED<br />
IN FRANCE<br />
DC INVERTER<br />
LOW<br />
TEMPERATURE<br />
HEATER<br />
LOW-TEMPERATURE<br />
RADIATOR<br />
CE STANDARD<br />
-<br />
OUTDOOR<br />
OPERATING LIMITS<br />
IN HEATING MODE<br />
BI-ZONE<br />
°C
7ACEL1592<br />
7ACFH0662<br />
7ACFH0543<br />
7ACFH0491 (alone)<br />
7ACFH0490 (kit)<br />
7ACFH0666<br />
BACKUP STARTING SWITCH<br />
This switch can be used to switch manually from priority heating<br />
of the compressor to additional heating.<br />
Wired ambient thermostat<br />
- Adjustment of ambient temperature<br />
- Daily or weekly programming<br />
- Holiday programming, no-frost mode<br />
MAIN OPTIONS AND ACCESSORIES<br />
43<br />
7ACEL1593<br />
300-litre domestic hot water tank<br />
(and 2.5 kW of electrical resistance heaters)<br />
optimised with the operation of the <strong>Aqu@Scop</strong> HT<br />
- Three authorisation modes<br />
- Holiday mode<br />
- Programmable anti-legionella function<br />
- Management of the three-way valve / circulator pump couple<br />
- 3.1m 2 exchange surface 7ACFH0663<br />
ON/OFF three-way valve<br />
Required for optional production of domestic hot water.<br />
Directs the produced hot water either towards the heating<br />
circuit or towards the domestic hot water tank. A second<br />
three-way valve is recommended for boiler-backup<br />
installation.<br />
Hydraulic kit<br />
For connecting to the boiler, available alone or in a<br />
complete kit with the three-way valve.<br />
Made up of a set of assembled pipes and valves,<br />
a set of connectors with spherical-conical seat.<br />
Decanting pot (sludge pot)<br />
Effectively separates the impurities from the heating<br />
circuit and collects them in a decanting chamber, where<br />
they can be bled off, even while the installation<br />
is operational.<br />
7ACFH0789<br />
(top outlet)<br />
7ACEL1801<br />
(bottom outlet)<br />
7ACTL0472<br />
Wireless thermostat with radio communication<br />
Sends the measured ambient temperature.<br />
140-litre buffer tank / mixing tank<br />
Necessary when the volume of water in the installation is<br />
insuf�cient. It protects the heat pump against short cycles<br />
that can reduce the useful life of the compressors and<br />
improves operation during defrosting phases.<br />
Domestic hot water kit<br />
Required when replacing existing installations.<br />
This kit, made up of a plate exchanger and a circulator<br />
pump, enables the production of domestic hot water<br />
using existing tanks (electric cumulus).<br />
Top outlet: sensor installed on the top outlet of the tank.<br />
If not possible, bottom outlet: sensor installed on the kit.<br />
Shock-absorbing support feet<br />
Raise the heat pump by 10cm, allow the evacuation of<br />
condensates and defrosting water.<br />
Their rubber design provides excellent shock absorption<br />
against the transmission of vibrations through solids.
Heat pumps |<br />
OPERATING LIMITS<br />
WATER CIRCULATOR PUMP PRESSURE FLOW CURVES<br />
ADVANCE 006 ADVANCE 012<br />
Available pressure<br />
kPa Bar<br />
60 0.6<br />
50 0.5<br />
40 0.4<br />
30 0.3<br />
20 0.2<br />
10 0.1<br />
0<br />
ADVANCE 016<br />
Available pressure<br />
0<br />
RESPECT FOR THE ENVIRONMENT WITH UP TO 80% LESS CO2 EMISSIONS<br />
The <strong><strong>Air</strong>well</strong> <strong>Aqu@Scop</strong> is a heating solution that makes the most of natural energy sources<br />
R410A<br />
800<br />
kPa bar<br />
60 0.6<br />
50 0.5<br />
40 0.4<br />
30 0.3<br />
20 0.2<br />
10 0.1<br />
0<br />
Water starting temperature (°C)<br />
Nominal flow<br />
rate<br />
HS<br />
MS<br />
LS<br />
70<br />
65<br />
60<br />
55<br />
50<br />
45<br />
40<br />
35<br />
30<br />
25<br />
20<br />
<strong>Aqu@Scop</strong><br />
<strong>Advance</strong><br />
while respecting the environment. It operates in a closed circuit and uses “green” R410A fluid<br />
which helps save the ozone layer.<br />
<strong>Aqu@Scop</strong> <strong>Advance</strong>-R<br />
-25 -20 -15 -10 -5 0 5 10 15 20<br />
1000 1200 1400 1600 1800 2000<br />
Water flow rate (l/h)<br />
HS<br />
Nominal flow<br />
rate<br />
0<br />
1300 1500 1700 1900 2100 2300 2500 2700 2900<br />
Water flow rate (l/h)<br />
Outside air temperature (°C)<br />
44<br />
Available pressure<br />
kPa Bar<br />
60 0.6<br />
50 0.5<br />
40 0.4<br />
30 0.3<br />
20 0.2<br />
10 0.1<br />
0<br />
0<br />
800<br />
25<br />
Nominal flow<br />
rate<br />
HS<br />
MS<br />
LS<br />
1000 1200 1400 1600 1800 2000<br />
Water flow rate (l/h)
AQU@SCOP @SCOP ADV ADVANCE<br />
TECHNICAL DAT ATA Heating floor application<br />
OUTDOOR AIR<br />
REGIME 7°C<br />
OUTDOOR AIR<br />
REGIME 2°C<br />
OUTDOOR AIR<br />
REGIME -7°C<br />
Application to radiators / fan coil units<br />
OUTDOOR AIR<br />
REGIME 7°C<br />
OUTDOOR AIR<br />
REGIME 2°C<br />
OUTDOOR AIR<br />
REGIME -7°C<br />
AIRWELL SOLUTIONS<br />
45<br />
ADV 006 ADV 012 ADV 016<br />
Floor heating power / water regime 30/35°C kW 6.62 (3.9 to 8.8) 10.76 (5.68 to 12.95) 15.47 (7.66 to 19.08)<br />
COP* 4.19 4.03 4.16<br />
Floor heating power / water outlet 35°C kW 4.96 8.56 11.77<br />
COP* 3.15 3.24 3.28<br />
Floor heating power / water outlet 35°C kW 3.7 6.9 9.01<br />
COP* 2.44 2.6 2.51<br />
Radiator heating power / water outlet 45°C kW 8.72 12.43 16.87<br />
COP* 3 2.82 3<br />
Radiator heating power / water outlet 45°C kW 6.6 10.33 13.41<br />
COP* 2.48 2.38 2.5<br />
Radiator heating power / water outlet 45°C kW 5.3 8.1 10.11<br />
COP* 2.04 1.9 2.01<br />
GROUPE Sound power dB(A) 63.5 65 65.5<br />
POWER SUPPLY<br />
1~230V-50Hz<br />
* COP values with defrosting.<br />
** According to application conditions.<br />
Sound pressure at 5 m in free �eld dB(A) 41.5 43 43.5<br />
Compressor type Inverter Rotary Scroll Scroll<br />
R410A �uid Kg 2 2.9 3.6<br />
Dimensions (WxDxH) mm 1232x401x905 1232x401x1307 1232x401x1307<br />
Weight Kg 125 175 185<br />
Outdoor temperature operating limits** °C -15 -15 -15<br />
Water outlet temperatures (mini/maxi) °C 25/55<br />
Exchanger type Plates<br />
Water intake/outlet connections inches 1” Female<br />
Expansion vessel l 3 5 5<br />
Electric backup (2 stages) kW 6(2+4) 6(2+4) 6(2+4)<br />
Power cable mm 2 3x10 3x16 3x16<br />
Protection rating A 40 63 63