07.05.2015 Views

Inductive proximity sensors

Inductive proximity sensors

Inductive proximity sensors

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Inductive</strong> <strong>proximity</strong> <strong>sensors</strong><br />

IQ 40 series, sensing range 15 / 20 mm<br />

DC 3-wire, plastic housing<br />

Dimensions in mm<br />

121<br />

41<br />

PG 13,5<br />

101<br />

27<br />

Features<br />

Can be installed flush or<br />

non-flush in metal<br />

Variable switching zone<br />

PNP output<br />

Programmable NO/NC<br />

function<br />

Short-circuit protection<br />

(pulsed)<br />

Plastic housing<br />

Terminal<br />

Enclosure rating IP 65<br />

LED status indicator<br />

Installation notes see page 17<br />

41<br />

32<br />

PG 13,5<br />

LED<br />

61,5<br />

10,4<br />

45,6<br />

5,1<br />

41<br />

77<br />

30<br />

Connection diagram<br />

PNP<br />

1/3<br />

X<br />

2/4<br />

progr.<br />

Programming with wirelinks<br />

Link closed: NO<br />

Link open:<br />

NC<br />

+<br />

DC<br />

-<br />

Terminal<br />

Assignment<br />

1/3 + V DC<br />

X<br />

NO/NC<br />

2/4 - V DC<br />

SICK


Electrical and mechanical data<br />

Operating voltage U b<br />

Voltage drop U d<br />

Power consumption<br />

(without load)<br />

Continuous current I a<br />

Time delay before<br />

availability t v<br />

Hysteresis H<br />

Repeatability R<br />

(U b<br />

and T a<br />

constant)<br />

Temperature drift<br />

EMC<br />

Selection table<br />

Sensing<br />

range s n<br />

mm<br />

Installation<br />

in metal<br />

10 ... 36 V DC<br />

≤ 2.5 V<br />

at I a<br />

max. and U b<br />

24 V<br />

≤ 15 mA<br />

≤ 250 mA<br />

approx. 4 ms<br />

1% - 15% of s r<br />

≤ 10% of s r<br />

± 10% of s r<br />

to EN 60 947-5-2<br />

Switching<br />

output<br />

Output<br />

function<br />

Switching<br />

frequency f<br />

in Hz<br />

Short-circuit protection<br />

(pulsed)<br />

Reverse polarity protection<br />

Power-up pulse suppression<br />

Enclosure rating to DIN 40050<br />

Protection class<br />

Shock and vibration<br />

stress<br />

Ambient temperature T a<br />

Housing material<br />

Connection<br />

yes<br />

yes<br />

yes<br />

IP 65<br />

30 g, 11 ms<br />

10 to 55 Hz, 1 mm<br />

- 25 ... + 80 °C<br />

Plastic<br />

Type<br />

Order number<br />

<strong>Inductive</strong> <strong>proximity</strong> <strong>sensors</strong>, IQ 40 series, DC<br />

15<br />

PNP<br />

progr.<br />

300<br />

Terminal up to<br />

2.5 mm 2<br />

IQ40-15BPP-KK0<br />

7900219<br />

20 PNP<br />

progr.<br />

300<br />

Terminal up to<br />

2.5 mm 2<br />

IQ40-20NPP-KK0<br />

7900221<br />

SICK


<strong>Inductive</strong> <strong>proximity</strong> <strong>sensors</strong><br />

IQ 40 series, sensing range 15 / 20 / 35 mm<br />

DC 3/4-wire, plastic housing<br />

Dimensions in mm<br />

66.5<br />

40 40<br />

Short version<br />

M12x1<br />

40<br />

17<br />

Features<br />

Can be installed flush or<br />

non-flush in metal<br />

Variable switching zone<br />

30<br />

20<br />

LED<br />

PNP output<br />

NO and complementary<br />

output function<br />

46<br />

Short-circuit protection<br />

(pulsed)<br />

Plastic housing<br />

61<br />

Connector<br />

Enclosure rating IP 67<br />

LED status indicator<br />

LED function indicator<br />

Installation notes see page 17<br />

Accessories<br />

Connection diagram<br />

Round connectors<br />

PNP<br />

1<br />

4<br />

3<br />

+<br />

DC<br />

-<br />

Contact Assignment<br />

1 + V DC<br />

4 NO<br />

3 - V DC<br />

2 free<br />

PNP<br />

complementary<br />

1<br />

4<br />

2<br />

3<br />

+<br />

DC<br />

-<br />

2<br />

Contact Assignment<br />

1 + V DC<br />

2 NC<br />

3 - V DC<br />

4 NO<br />

3<br />

1<br />

4<br />

SICK


Electrical and mechanical data<br />

Operating voltage U b<br />

Voltage drop U d<br />

Power consumption<br />

(without load)<br />

Continuous current I a<br />

Time delay before<br />

availability t v<br />

Hysteresis H<br />

Repeatability R<br />

(U b<br />

and T a<br />

constant)<br />

Temperature drift<br />

EMC<br />

Selection table<br />

Sensing<br />

range s n<br />

mm<br />

Installation<br />

in metal<br />

10 ... 36 V DC<br />

≤ 2.5 V<br />

at I a<br />

max. and U b<br />

24 V<br />

≤ 15 mA<br />

≤ 250 mA<br />

approx. 4 ms<br />

1% - 15% of s r<br />

≤ 10% of s r<br />

± 10% of s r<br />

to EN 60 947-5-2<br />

Switching<br />

output<br />

Output<br />

function<br />

Switching<br />

frequency f<br />

in Hz<br />

Short-circuit protection<br />

(pulsed)<br />

Reverse polarity protection<br />

Power-up pulse suppression<br />

Enclosure rating to DIN 40050<br />

Protection class<br />

Shock and vibration<br />

stress<br />

Ambient temperature T a<br />

Housing material<br />

Connection<br />

yes<br />

yes<br />

yes<br />

IP 67<br />

30 g, 11 ms<br />

10 to 55 Hz, 1 mm<br />

- 25 ... + 70 °C<br />

Plastic<br />

Type<br />

Order number<br />

<strong>Inductive</strong> <strong>proximity</strong> <strong>sensors</strong>, IQ 40 series, DC<br />

15<br />

PNP<br />

300<br />

Connector M12 x 1 mm<br />

IQ40-15BPS-KC0<br />

7900223<br />

20<br />

PNP<br />

antivalent<br />

200<br />

Connector M12 x 1 mm<br />

IQ40-20NPP-KCK<br />

6012014<br />

35<br />

PNP<br />

100<br />

Connector M12 x 1 mm<br />

IQ40-35NPS-KC0<br />

7900224<br />

35<br />

PNP<br />

antivalent<br />

100<br />

Connector M12 x 1 mm<br />

IQ40-35NPP-KCK<br />

6012015<br />

SICK


<strong>Inductive</strong> <strong>proximity</strong> <strong>sensors</strong><br />

IQ 40 series, sensing range 15 / 20 mm<br />

AC / DC 2-wire, plastic housing<br />

Dimensions in mm<br />

41<br />

PG 13.5<br />

121<br />

101<br />

27<br />

41<br />

Features<br />

Can be installed flush or<br />

non-flush in metal<br />

Variable switching zone<br />

Broad operating voltage range<br />

in AC and DC<br />

Programmable switching<br />

output: NO or NC<br />

Plastic housing<br />

Enclosure rating IP 65<br />

Terminal connection<br />

LED status indicator<br />

41<br />

32<br />

PG 13.5<br />

LED<br />

61.5<br />

10.4<br />

77<br />

45.6<br />

5.1<br />

30<br />

Connection diagram<br />

progr.<br />

1/3<br />

2/4<br />

L1 / +<br />

AC/DC<br />

N/-<br />

Programming with wire links<br />

Link closed:<br />

NO<br />

Link open:<br />

NC<br />

Terminal Assignment<br />

1/3 L1 / +<br />

2/4 N / -<br />

SICK


Electrical and mechanical data<br />

Operating voltage U b<br />

Voltage drop U d<br />

Continuous current I a<br />

Peak current I K<br />

Min. load current<br />

Residual current<br />

Time delay before<br />

availability t v<br />

Hysteresis H<br />

Repeatability R<br />

(U b<br />

and T a<br />

constant)<br />

Temperature drift<br />

EMC<br />

Selection table<br />

Sensing<br />

range s n<br />

mm<br />

15<br />

20<br />

Installation<br />

in metal<br />

20 ... 250 V AC / DC<br />

≤ 6.5 V AC / ≤ 6 V DC<br />

at I a<br />

max.<br />

≤ 350 mA AC (... + 50 °C)<br />

≤ 250 mA AC (... + 80 °C)<br />

≤ 100 mA DC<br />

2.2 A (20 ms / 0.5 Hz)<br />

5 mA<br />

≤ 2.5 mA (250 V AC)<br />

≤ 1.3 mA (110 V AC)<br />

≤ 0.8 mA (24 V DC)<br />

approx. 8 ms<br />

1% - 15% of s r<br />

≤ 10% of s r<br />

± 10% of s r<br />

to EN 60 947-5-2<br />

Output<br />

function<br />

progr.<br />

progr.<br />

Switching frequency f<br />

in Hz<br />

20 (AC) / 55 (DC)<br />

20 (AC) / 55 (DC)<br />

Wire-break protection<br />

Short-circuit protection<br />

(pulsed)<br />

Reverse polarity protection<br />

Power-up pulse suppression<br />

Enclosure rating to DIN 40050<br />

Protection class<br />

Shock and vibration<br />

stress<br />

Ambient temperature T a<br />

Housing material<br />

Connection<br />

Terminal up to<br />

2.5 mm 2<br />

Terminal up to<br />

2.5 mm 2<br />

-<br />

-<br />

-<br />

yes<br />

IP 65<br />

30 g, 11 ms<br />

10 to 55 Hz, 1 mm<br />

- 25 ... + 80 °C<br />

Plastic<br />

Type<br />

IQ40-15BUP-KK0<br />

IQ40-20NUP-KK0<br />

Order number<br />

7902136<br />

7902137<br />

<strong>Inductive</strong> <strong>proximity</strong> <strong>sensors</strong>, IQ 40 series, AC / DC<br />

SICK

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!