<strong>Inductive</strong> <strong>proximity</strong> <strong>sensors</strong><strong>IH</strong> <strong>34</strong> <strong>series</strong>, <strong>sensing</strong> <strong>range</strong> <strong>20</strong> <strong>mm</strong>DC 3-wire, plastic housingDimensions in <strong>mm</strong>LEDØ <strong>34</strong>80110FeaturesCan be installed non-flushin metalPNP or NPN outputHigh switching frequencyShort-circuit protection(pulsed)Ø <strong>34</strong>LED, 360°M12 x 1Plastic housingCable or connectorEnclosure rating IP 678090LED status indicator(with 360° connectors)AccessoriesRound connectorsMounting clampsConnection diagramPNPbnbkbu143+DC-NPNbnbkbu143+DC-Wire colour Contact Assignmentbn brown 1 + V DC2bk black 4 NObu blue 3 - V DC312 free 4SICK


Electrical and mechanical dataOperating voltage U bRipple U ppVoltage drop U dPower consumption(without load)Continuous current I aTime delay beforeavailability t vHysteresis HRepeatability R(U band T aconstant)Temperature driftEMCSelection tableSensing<strong>range</strong> s n<strong>mm</strong>Installationin metal10 ... <strong>30</strong> V DC≤ 10% of U b≤ 1.5 Vat I amax.≤ 10 mA≤ <strong>30</strong>0 mA≤ 10 ms1% - 10% of s r≤ 2% of s r± 10% of s rto EN 60 947-5-2SwitchingoutputOutputfunctionSwitchingfrequency fin HzWire-break protectionShort-circuit protection(pulsed)Reverse polarity protectionPower-up pulse suppressionEnclosure rating to DIN 40050Shock and vibrationstressAmbient temperature T aHousing materialConnection cableConnectionyesyesyesyesIP 67<strong>30</strong> g, 11 ms10 to 55 Hz, 1 <strong>mm</strong>- 25 ... + 75 °CPlasticPUR-PVC, 3 x 0.5 <strong>mm</strong> 2TypeOrder number<strong>Inductive</strong> <strong>proximity</strong> <strong>sensors</strong>, <strong>IH</strong> <strong>34</strong> <strong>series</strong>, DC<strong>20</strong><strong>20</strong><strong>20</strong><strong>20</strong>PNPNPNPNPNPN500500500500Cable 2 mCable 2 mConnector M12 x 1 <strong>mm</strong>Connector M12 x 1 <strong>mm</strong><strong>IH</strong><strong>34</strong>-<strong>20</strong>NPS-KU0<strong>IH</strong><strong>34</strong>-<strong>20</strong>NNS-KU0<strong>IH</strong><strong>34</strong>-<strong>20</strong>NPS-KC0<strong>IH</strong><strong>34</strong>-<strong>20</strong>NNS-KC07900189790019079001917900192SICK


<strong>Inductive</strong> <strong>proximity</strong> <strong>sensors</strong><strong>IH</strong> <strong>34</strong> <strong>series</strong>, <strong>sensing</strong> <strong>range</strong> <strong>20</strong> / <strong>30</strong> <strong>mm</strong>AC / DC 2-wire, plastic housingDimensions in <strong>mm</strong>LEDØ <strong>34</strong>Ø 9608218FeaturesCan be installed non-flushin metalCan also be supplied withincreased switching distanceBroad operating voltage <strong>range</strong>in AC and DCNormally open/normally closed functionPlastic housingEnclosure rating IP 67LED status indicatorAccessoriesMounting clampsConnection diagrambnbubnbuL1 / +AC/DCN/-L1 / +AC/DCN/-Wire colourAssignmentbn brown L1 / +bu blue N / -SICK


Electrical and mechanical dataOperating voltage U bVoltage drop U dContinuous current I aPeak current I KMin. load currentResidual currentTime delay beforeavailability t vHysteresis HRepeatability R(U band T aconstant)Temperature driftEMCSelection tableSensing<strong>range</strong> s n<strong>mm</strong><strong>20</strong><strong>20</strong><strong>30</strong><strong>30</strong>Installationin metal<strong>20</strong> ... 250 V AC / DC≤ 6.5 V AC / ≤ 6 V DCat I amax.≤ 350 mA AC (... + 50 °C)≤ 250 mA AC (... + 80 °C)≤ 100 mA DC2.2 A (<strong>20</strong>ms / 0.5 Hz)5 mA≤ 2.5 mA (250 V AC)≤ 1.3 mA (110 V AC)≤ 0.8 mA (24 V DC)approx. 8 / 50 ms(with s n<strong>20</strong> / <strong>30</strong> <strong>mm</strong>)1% - 15% of s r≤ 10% of s r± 10% of s rto EN 60 947-5-2OutputfunctionSwitching frequency fin Hz<strong>20</strong><strong>20</strong>77Wire-break protectionShort-circuit protection(pulsed)Reverse polarity protectionPower-up pulse suppressionEnclosure rating to DIN 40050Protection classShock and vibrationstressAmbient temperature T aHousing materialConnection cableConnectionCable 2 mCable 2 mCable 2 mCable 2 m---yesIP 67<strong>30</strong> g, 11 ms10 to 55 Hz, 1 <strong>mm</strong>- 25 ... + 80 °CPlasticPUR-PVC, 2 x 0.5 <strong>mm</strong> 2Type<strong>IH</strong><strong>34</strong>-<strong>20</strong>NUS-KU0<strong>IH</strong><strong>34</strong>-<strong>20</strong>NUO-KU0<strong>IH</strong><strong>34</strong>-<strong>30</strong>NUS-KU0<strong>IH</strong><strong>34</strong>-<strong>30</strong>NUO-KU0Order number7902132790213379021<strong>34</strong>7902135<strong>Inductive</strong> <strong>proximity</strong> <strong>sensors</strong>, <strong>IH</strong> <strong>34</strong> <strong>series</strong>, AC / DCSICK