Technical Specifications<br />

GENERAL<br />

Sensor Type_____________ Non-dispersive infrared<br />

Detection Range ________ See “Ordering Information”<br />

Linearity ________________ ± 2% below 40% full scale<br />

± 5% from 40% to 110% full scale<br />

Repeatability ____________ ± 2% below 40% full scale<br />

± 5% from 40% to 110% full scale<br />

Response Time __________ T90 < 5 seconds (without<br />

rainshield)<br />

Start Up Time ___________ 30 seconds<br />

Self-Diagnostic Test ____ 2x per second<br />

Calibration ______________ Span: none (factory set)<br />

Zero: every 3 to 6 months<br />

User Interface ___________ Non-intrusive via magnet<br />

Display__________________ 4 digit LCD with user-adjustable<br />

contrast. Numeric display of gas<br />

concentration and faults; icons<br />

for alarms, lock, and inhibit<br />

Weight __________________ 6.5 lbs (3.0 kg)<br />

Warranty ________________ 2 years<br />

OUTPUTS<br />

Analog __________________ Isolated, 4-20mA, max loop load<br />

900ohms at 24 VDC (current<br />

source or sink)<br />

Programmable Fault_____ 2.4 to 4.0mA<br />

Programmable Inhibit ___ 1.5 to 20.0mA<br />

Programmable Loop Test 1.0 to 20.0mA<br />

Digital __________________ RS/485 or RS/232 using Modbus<br />

RTU or Modbus ASCII protocol<br />

Relay (optional) _________ 3 SPST relays (2 concentration, 1<br />

fault), 5A at 250 VAC. Userselectable<br />

latching/nonlatching,<br />

energized/de-energized, set/reset<br />

delay, and set/reset point<br />

ELECTRICAL<br />

Input Voltage____________ 18-27VDC<br />

Power Consumption ____ 3.1W, nominal / 6.0W, max<br />

Connections ____________ 3 wires or 4 wires (with RS/485 or<br />

RS/232 configuration ); 18-22<br />

AWG nominal<br />

RFI/EMI __________________ certified to EN50082-1<br />

ENVIRONMENTAL<br />

Operating Temp _________ -40°F to 140°F (-40°C to 60°C)<br />

Operating Humidity _____ 0 to 100% RH<br />

Installation Drawings<br />

Electrical<br />

Dimensions<br />

Bump Test Adaptor<br />

P/N 096-2289<br />

A(-)<br />

B(+)<br />

ENCLOSURE<br />

Enclosure Material ______ Copper-free cast aluminum, baked<br />

epoxy finish<br />

Optical Bench Material __ Stainless steel or electroplated<br />

aluminum<br />

APPROVALS<br />

Enclosure _______________ Explosion proof; UL/FM/CSA, Class<br />

1 Group B,C,D / Class 2, Group E, F<br />

/ Class 3, NEMA-4X, NEMA-7B, C,D;<br />

NEMA-9 E,F,G; IP66<br />

System __________________ ETL listed to UL2279 and UL3111-1<br />

(Class 1, Div 1, Group B,C,D ),<br />

CE Marked<br />

CSA approved to Class 1, Zone<br />

1,Groups IIB+H2;Class I, Groups<br />

E,F,&G; Class III<br />

CENELEC approved to EExd[ib] IIc T6<br />

Represented by:<br />

Toll Free US and Canada<br />

1-800-872-8008<br />

251 Welsh Pool Rd., Exton, PA 19341<br />

(PH) 610-363-5450 • (FAX) 610-363-0167<br />

(email) info@scottinstruments.com<br />

(WEB) www.scottinstruments.com<br />

or<br />

DS-4688-IR 08-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!