TM<strong>Vortex</strong> <strong>Flow</strong> <strong>Meters</strong>RNG SeriesInsertion-StyleGas <strong>Flow</strong> Meter• Applications:Flare gasStack gasNatural gasDigester gas (BioGas: CH 4 + CO 2 )Air• Not sensitive to gas composition changes• High accuracy in wet gas applications• 70:1 turndown ratio• HART ® Communications ProtocolTel: 262-639-6770Toll Free: 888-5RACINE


RNG Series Insertion-Style Gas <strong>Flow</strong> MeterThe RNG Series meter is an insertion-style vortex shedding flow meter designed to offer high accuracy measurements over an extremely large flowrange. The meters have no moving parts and are virtually maintenance-free once installed. The RNG Series is suitable for most gas types, including air,natural gas and wet or “biogas” applications. All meters in this series are loop-powered devices with standard HART ® communications for ease of fieldprogramming and system integration.Operating PrincipleAn everyday example of a vortex shedding phenomenon is a flag wavingin the breeze: the flag waves due to the vortices shed by air movingacross the flagpole. Within the flow meter, as flowing gas moves acrossthe tiny strut or “bluff bar”, vortices are also shed but on a smaller scale.The meter transmits an ultrasonic beam through the vortex patterndownstream of the strut. As vortices are shed, the carrier wave of theultrasonic signal is modified. This change in the carrier wave ismeasurable and moves in proportion to the number of vortices shed.Digital processing enables the vortices to be counted, and this value isFLOWconverted into a velocity. Software converts velocity into a volumetricflow rate, in units of measure selected by the operator.Racine <strong>Vortex</strong> flow meters utilize the smallest strut in the industry, whichallows for high sensitivity; superior performance at very low flow rates;large turndown ratios; and low pressure drop.Through the use of an internal RTD and an external pressure sensor(optional), the flow meter software will compensate for changes inpressure and temperature, to achieve an accurate mass flow measurement.Transmitting TransducerSmall StrutShed VorticesReceiving TransducerSpecificationsMeasured:Gas/AirVelocity Range:2 to 140 FPS (0.6 to 43 MPS)Operating Temperature: -20 °F to 300 °F (-28 °C to 150 °C)Ambient Temperature Limits: -20 °F to 155 °F (-28 °C to 68 °C)Operating Pressure: -5 to 250 PSIGAccuracy:1% of reading over dynamic range of meterRepeatability:0.5% of readingResponse Time:150 milliseconds maximumInput Power:15-24 VDCSignal Output:2-wire, 4-20 mA loopConstruction: Stainless steel wetted parts with Teflon ®transducers, NEMA 7 transmitter enclosureStandard:2" 150# ANSI FlangeOptional:2" 300# ANSI Flange2" MNPT CouplingDN 50 Metric FlangeCommunications:HART ® Protocol (Via PC or HART Modem)Certifications:CEOptional ATEX (EEx ib IIB T4) Zone 1, Group IIB, T4(Equiv. to N.A. Class I, Div 1, Groups C & D, T4)Options:2 line, 8 digit rate/totalizer displayInternal RTD temperature compensation formass flow measurement2 Tel: 262-639-6770


<strong>Flow</strong> Ranges*<strong>Flow</strong> Range in SCFM, 60 °F in AIR<strong>Flow</strong> Range in Nm 3 /HR, 16 °C in AIRPipeSize3"76 mm4"102 mm6"152 mm8"203 mm10"254 mm12"305 mmMIN.20.620.620.620.620.620.6PRESSURE IN PSIG (BARg)0 (0) 25 (1.7) 50 (3.4) 75 (5.2) 100 (6.9) 150 (10.3)MAX.140431404314043140431404314043MIN.1626284564102113182177284255409MAX.11141790198031834455716179201273112375198931782028646MIN.26424674104167184296288463415667MAX.1815291732275187726111672129082074920169324212904346686MIN.365864103144231256411399642575925MAX.25174045447471921006716182178962876727963449494026664727MIN.4674821311842963275265118217361182MAX.32185173572191961287220692228843678535757574775148982767MIN.66106117189264424469755733117910561698MIN.4621742882151320518484297123286052822513448253473936118848Pressure Drop(Inches H 2 O) at50% Max. <strong>Flow</strong>**10.70.60.40.20.1*Consult RACINE <strong>Flow</strong> Meter Sizing Software for temperature and pressure conditions other than those listed hereConsult factory for larger pipe sizes**Pressure drop data for air at 14.7 psi and 60 °F (0 BARg and 16 °C)Part Number ConstructionRNG Series Insertion <strong>Flow</strong> <strong>Meters</strong> for GasR N G d d - e e e f g h iRacine Insertion Gas StemLengthMounting Style/Cable LengthMeterMaterialDisplayMass <strong>Flow</strong>Comp.ApprovalsAll meters include 4-20 mA output, HART ® commuications protocol and NEMA 7 XP transmitter enclosurePart Number:ddStem Length12) 12" Stem24) 24" Stem36) 36" Stem48) 48" Stem60) 60" StemR N G d d - e e e f g heeeMounting Style/Cable Length150) 2" x 150# Flange 1151) 2" x 150# Flange + 10' cable 2152) 2" x 150# Flange + 25' cable 2153) 2" x 150# Flange + 50' cable 2300) 2" x 300# Flange 1301) 2" x 300# Flange + 10' cable 2302) 2" x 300# Flange + 25' cable 2303) 2" x 300# Flange + 50' cable 2NPT) 2" MNPT Fitting 1NP1) 2" MNPT Fitting + 10' cable 2NP2) 2" MNPT Fitting + 25' cable 2NP3) 2" MNPT Fitting + 50' cable 2D50) DN 50 Flange 1D51) DN 50 Flange 2,3D52) DN 50 Flange 2,3D53) DN 50 Flange 2,3g DisplayN) No DisplayD) Integral 8-Digit TotalizerLCD 4f Meter MaterialS) 316SS (standard)T) Teflon ® Coated 316SS(all wetted parts)1Integral mount transmitter2Remote mount transmitter (Not available with ATEX version)3Flange to DIN 2527 specifications4Not available with ATEX version5Also required when external pressure sensor will be usedii ApprovalsS) CE (Standard)A) ATEX Zone 1, Group II B,T4h Mass <strong>Flow</strong> CompensationN) No Temperature Input orMass <strong>Flow</strong> CompensationT) Integral RTD, TemperatureCompensation for Mass<strong>Flow</strong> Measurement 5Fax: 262-639-22673

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!