12.05.2015 Views

Metric Engineering - KeyWestCity.com

Metric Engineering - KeyWestCity.com

Metric Engineering - KeyWestCity.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SR 826 (Palmetto Expressway) at N.W. 36 th Street – Miami-Dade County: Project Engineer for the design and plans<br />

preparation of Permanent Steel Sheet Pile Bulkheads, Reinforced Concrete Endwalls, Cofferdam and multiple<br />

cantilever, span and butterfly sign structures as well as post design services. Client: FDOT District 6, Contact: Mr. Ali<br />

Toghiani, P.E. 305-470-5343, Begin/End Dates: March 2002-June 2006<br />

MIC Interchange at Lejeune Road – Project Engineer for the design and preparation of a 285’ prestressed AASHTO<br />

beams bridge and a 968’ long steel box girder bridge, including post design services. Client: FDOT District 6, Contact:<br />

Mr. Gary Donn, P.E. (305) 470-5343, Begin/End Dates: September 2004-June 2008<br />

Kendall Cottages – General Services Administration. Project Engineer responsible for the 40 year structural<br />

certification of multiple county buildings, site plans and illumination improvements. Client: Miami-Dade Housing<br />

Authority, Contact: Ms. Ivette Newland, PE. (305) 375-2063, Begin/End Dates: September 2004-March 2007<br />

S.R. 826 at I-75 Northbound – Miami-Dade County: Project Engineer for the design of a MSE wall widening and<br />

multiple sign structures including span and cantilever structures. Client: FDOT District 6, Contact: Mr. Ali Toghiani,<br />

P.E. 305-470-5343<br />

13 th Street SW Bridge over the Golden Gate Canal – Collier County, Florida. Project Engineer for the design and<br />

preparation of a bridge development report, plans and documents and shop drawings for a three span (42.75’; 43.417’;<br />

42.75’) bridge. This bridge is <strong>com</strong>posed of eleven precast prestressed concrete box beams supported by pile cap end<br />

and intermediate bents. Collier County Project No. 60012 (239)-530-5335<br />

Building Experience<br />

Alexander Orr WTP Onsite Generation Building, Miami-Dade Water and Sewer Department - Engineer of<br />

Record in charge of the design and plans preparation of a 43' high reinforced masonry building. Design included a<br />

second story, stairs, masonry openings and louver installations. This important building is located inside the Alexander<br />

Orr Water Treatment Plant in Miami-Florida. Structural specifications required the capacity of elements to withstand a<br />

heavy corrosion industrial facility. Client: Miami-Dade Water and Sewer Department, Contact: Brian Trujillo, PE (305)<br />

588-4565, Begin/End Dates: June 2009-June 2010<br />

MIA Station - MIA Mover Project, Miami-Dade Aviation Department - Project Engineer in the design/build project of<br />

a people mover train station at Miami International Airport. Structure spans over the existing roadway configuration by<br />

means of 5 spans for a total length of 285’ at the airport and supports a maintenance level and a passenger level.<br />

Design tasks include the concrete design of cast in place substructure, columns and footings and superstructure<br />

elements, connecting beams utilizing the Florida Building Code.<br />

Steel Towers – Polk County (TECO Plant) - Analysis of Steel Towers designed for electrical equipment. Project<br />

included three (3) towers with <strong>com</strong>plex equipment configurations, Steel design for varied steel shapes and Concrete<br />

design for multiple isolated concrete footings, pedestals and concrete slabs.<br />

Kendall Cottages – General Services Administration. Project Engineer responsible for the 40 year structural<br />

certification of multiple county buildings, site plans and illumination improvements.<br />

Aerothrust Building – General Services Administration / MDAD. Project Engineer assisting in the structural<br />

inspection and report preparation of the Aerothrust Building at Miami International Airport. Building presented cracking<br />

and minor spalls throughout floor slabs and fascia walls.<br />

<strong>Metric</strong> <strong>Engineering</strong>, Inc.<br />

Page Three