Embedded Power AC-DC and DC-DC Power Conversion ... - Codico
Embedded Power AC-DC and DC-DC Power Conversion ... - Codico
Embedded Power AC-DC and DC-DC Power Conversion ... - Codico
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Bulk <strong>Power</strong><br />
HPR12K<br />
Output<br />
Output rating<br />
Set point<br />
Total regulation range<br />
Rated load<br />
Minimum load<br />
Output noise<br />
Output voltage overshoot<br />
Transient response<br />
Max units in parallel<br />
Short circuit protection<br />
Output isolation<br />
Forced load sharing<br />
Overcurrent protection<br />
(OCP)<br />
Overvoltage protection<br />
(OVP)<br />
Overtemperature<br />
protection<br />
48 V @ 62.0 A (180-264 Vac)<br />
5 Vsb @ 3.0 A<br />
48 V @ 29.4 A (90-140 Vac)<br />
5 V @ 3 A<br />
-4% to +17% through I 2 C<br />
48 V ±10%; 5 Vsb ±4% (line/load/transient when<br />
measured at output connection)<br />
3000 W maximum @ 200 Vac Input<br />
1500 W maximum @ 110 Vac Input<br />
(no derating over operating temperature range)<br />
48 V @ 0.0 A; 5 Vsb @ 0.0 A with no loss<br />
of regulation<br />
480 mV max P-P for 48 V output<br />
100 mV max P-P for 5 Vsb output<br />
Measured with a 0.1μF Ceramic <strong>and</strong> 10 μF<br />
Tantalum capacitor on any input<br />
±5% maximum of nominal voltage setting<br />
5% maximum deviation<br />
(50% load step @ 1 A/us. Step load valid<br />
between 10-100% of output rating)<br />
Up to 4 (total power in 1U 19” rack is 12 KW)<br />
120-130% of rated output (output to return)<br />
Per POE specs (>2000 Vac)<br />
Within 10% of all shared outputs<br />
(digital sharing control)<br />
120-130% for 48 V output<br />
100-125% for 5 Vsb output<br />
110-120% for 48 V output<br />
110-125% for 5 Vsb output<br />
10 °C to 15 °C above safe operating area.<br />
(Both PFC <strong>and</strong> output converter monitored.<br />
5 Vsb will operate under overtemperature<br />
condition. Built-in hysteresis.)<br />
Rack Ordering Information<br />
Module UFE1300/2000 HPS3000<br />
Rack # UFR6000 HPR12K<br />
# of Slots 3 4<br />
Total <strong>Power</strong> 6000 W 12000 W<br />
**See website for option codes on HPR racks.<br />
Ordering Information<br />
HPS3000-0-001<br />
HPS3000<br />
HPS3000-0-001<br />
HPS3000-9<br />
42 For complete product specifications, technical reference notes <strong>and</strong> available product options, go to www.Emerson.com/<strong>Embedded</strong><strong>Power</strong>.