CAN <strong>connections</strong><br />

3) CAN High & Low in LEMO Female (CB)<br />

1 = GND (white)<br />

2 = <strong>+24</strong> V (brown)<br />

3 = CAN1 H (yellow)<br />

4 = CAN1 L (green)<br />

5 = CAN EN (grey)<br />

6 = Case GND (grey)<br />

2) CAN High & Low in M12 connector<br />

CAN H: Voltage between GND & CAN H should be a little bit over 2,5V.<br />

CAN L: Voltage between GND & CAN L should be a little bit below 2,5V.<br />

1 = GND (white)<br />

2 = <strong>+24</strong> V (brown)<br />

3 = CAN1 H (yellow)<br />

4 = CAN1 L (green)<br />

Male M12<br />

Female M12<br />

2) CAN High & Low in LEMO<br />

1 = GND (white)<br />

2 = <strong>+24</strong> V (brown)<br />

3 = CAN1 H (blue)<br />

4 = CAN1 L (black)<br />

5 = CAN EN (grey), link 5-6<br />

and Rubber Gaiter GND<br />

6 = Case GND (grey) , link 5-6<br />

1) CAN High & Low in<br />

AMP 14-pin connector<br />

Check that the pins are<br />

inserted in correct way<br />

and in correct places.<br />

2 = CAN 1 H (2024)<br />

3 = CAN 1 L (2024)<br />

6 = CAN 2 H (CABIN)<br />

7 = CAN 2 L (CABIN)<br />

CAN1 H (yellow)<br />

CAN1 L (green)<br />

1) CAN High & Low in AMP 8-pin connector<br />

Check that the pins are inserted in correct<br />

way and in correct places.<br />

2 = CAN 1 H (yellow) 6 = CAN 1 L<br />

Check also that CAN<br />

aren’t connected to<br />

each other.