28.05.2015 Views

Planning Documents for OR

This Planning Document was developed to enhance your knowledge of the Dräger portfolio and to provide guidance when designing a new OR. This document contains an overview of Dräger products and their corresponding technical data. The last pages of this document show several exemplary Dräger solutions for different disciplines likes heart surgery or neurosurgery, including detailed technical drawings of the individual workplaces.

This Planning Document was developed to enhance your knowledge of the
Dräger portfolio and to provide guidance when designing a new OR. This
document contains an overview of Dräger products and their corresponding
technical data.
The last pages of this document show several exemplary Dräger solutions for
different disciplines likes heart surgery or neurosurgery, including detailed
technical drawings of the individual workplaces.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

22 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> <strong>OR</strong> |<br />

DRÄGER P<strong>OR</strong>TFOLIO<br />

Ceiling fixtures <strong>for</strong> <strong>OR</strong> lights/display arms<br />

PRODUCT DESCRIPTION<br />

The Dräger ceiling mount supports the installation<br />

of lights and display holders (on the<br />

central axis). The <strong>OR</strong> light/display arm can be<br />

fixed directly under the concrete ceiling<br />

(direct mounting). The distance tube allows<br />

mounting at heights of up to 1200 mm under<br />

a concrete ceiling in order to bridge the space<br />

above a false ceiling. The installation manuals<br />

are included with delivery.<br />

MOUNTING OPTIONS<br />

Direct mount<br />

This system is recommended as a direct<br />

mount or <strong>for</strong> use with a false ceiling up to a<br />

distance of 600 mm between the concrete<br />

and false ceiling or in combination with a laminar<br />

flow system. The suspension tube is available<br />

in five standard lengths (220/460/630/<br />

800/1000 mm). For service purposes, it<br />

should be considered that the electrical components<br />

must be installed in a switch box near<br />

the <strong>OR</strong> (max. 40 m).<br />

D-90851-2013<br />

With ceiling cover<br />

D-90851-2013<br />

With flat cover<br />

With laminar flow ceiling<br />

Distance tube<br />

This system is recommended <strong>for</strong> use with distances<br />

> 600 mm between the concrete and<br />

false ceiling or in combination with a laminar<br />

flow system. The distance tube is available in<br />

two standard lengths (600/1200 mm). For<br />

service purposes, it should be considered that<br />

the electrical components must be installed in<br />

a switch box near the <strong>OR</strong> (max. 40 m).<br />

D-90851-2013<br />

D-90851-2013<br />

With ceiling cover<br />

With flat cover<br />

With laminar flow ceiling<br />

Axis system Arm lengths Spring load arm lengths Vertical <strong>for</strong>ce (F) Torque (M)<br />

1-fold axis<br />

1f axis xxx 850 mm 930 mm 960 N 910 Nm<br />

1f axis AC2000 display 700 mm 930 mm 870 N 460 Nm<br />

1f axis AC3000 display 750 mm 930 mm 940 N 700 Nm<br />

1f axis xxx 1150 1150 mm 930 mm 1000 N 760 Nm<br />

1f axis xxx 1450 1450 mm 930 mm 1030 N 640 Nm<br />

2-fold axis<br />

2f axis xxx/xxx 700/850 mm 930 mm 1530 N 1280 Nm<br />

2f axis xxx/xxx 1150 700/1150 mm 930 mm 1400 N 1260 Nm<br />

3-fold axis<br />

3f axis xxx/xxx/xxx 700/850/1000 mm 930 mm 1920 N 1850 Nm<br />

4-fold axis<br />

4f axis xxx/xxx/xxx/xxx 700/850/1000/1150 mm 930 mm 2490 N 2680 Nm