Repeated Absorption Interval<br />

The repeated absorption interval, can be set at 1 – 45 days.<br />

Set the DS 3-7 Set the repeated absorption interval Example<br />

DS-8<br />

DS-7<br />

DS-6<br />

DS-5<br />

DS-4 on<br />

DS-3<br />

DS-2<br />

DS-1<br />

off<br />

off<br />

off<br />

off<br />

Increments are 1 day.<br />

Determine the required reduced float<br />

time Tq.<br />

Determine the setting number.<br />

Scale = 1 day<br />

Offset = 0<br />

Setting number = Tq<br />

Determine the LED indication.<br />

Press the pushbuttons until the<br />

required LED indication is displayed.<br />

Required: reduced float time is 1<br />

week.<br />

Setting number = 7.<br />

LED indication =<br />

0 1<br />

0 2<br />

0 2<br />

0 2<br />

0 7<br />