SNAP-CLAD<br />

Technical Information and<br />

Flashing Details<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


Product Information:<br />

PAGE 3<br />

SNAP-CLAD Spec. Sheet<br />

PAGES 4-13<br />

UL List Cards - UL Construction Numbers<br />

261, 254, 255, 263, 343, 303, 508, 508A, 614, 790<br />

PAGE 14<br />

UL Construction Code<br />

Miami-Dade/Florida Product Approvals<br />

PAGES 15-38<br />

SNAP-CLAD Flashing Details<br />

PAGES 39-42<br />

SPEC-DATA® Sheet<br />

PAC, Petersen Aluminum Corporation reserves the right to discontinue products at any time or change<br />

specification and/or designs without notice and without incurring obligation. Application details are<br />

for illustration purposes only, and may not be appropriate for all environmental conditions, building<br />

designs, or panel profiles. Projects should be engineered to conform to applicable building codes,<br />

regulations, and accepted industry practices. Descriptions and specifications contained herein were in<br />

effect at the time this publication was approved for printing. Petersen Aluminum Corporation does not<br />

build or design buildings. It acts solely as a supplier of materials, and assumes no responsibility for the<br />

proper use or installation of those materials, nor for the suitability of those materials for any specific use<br />

or for compliance with local building codes.<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

2<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


SNAP-CLAD<br />

sealant bead (optional)<br />

1-3/4"<br />

10", 12", 16" or 18" O.C.<br />

SNAP-CLAD <br />

10”, 12”, 16” or 18” O.C. .032 aluminum<br />

1-3/4” high .040 aluminum<br />

24 gauge steel<br />

22 gauge steel<br />

16 oz. copper<br />

U.L. Construction Numbers 261, 254, 255, 343, 303, 508, 508A, 614<br />

SNAP-CLAD Panels feature architectural panel aesthetics as well as structural panel performance.<br />

These panels carry a U.L. rating over a wide variety of assemblies as indicated by the above listed U.L.<br />

Construction numbers.<br />

Features:<br />

Requirements:<br />

.032 aluminum, .040 aluminum, 24 ga. steel, or 22 ga. steel, 16 oz. copper<br />

(Standard Colors are limited in 22 ga. steel & .040 aluminum)<br />

10” o.c., 12” o.c., 16” o.c., 18” o.c.<br />

Factory Applied Sealant Bead in Seam (Optional)<br />

Tension Leveled<br />

Available Smooth, with Stiffening Beads or with Striations<br />

Factory Eave Notching<br />

Solid Substrate, Open Framing, or Rigid Insulation<br />

Vapor Barrier (on solid substrate and rigid insulation)<br />

Clips (U.L. 90 Clip or Standard Clip)<br />

Bearing Plates: Required when used in assembly including rigid insulation over<br />

metal decking.<br />

Minimum Roof Pitch: 2” on 12”<br />

(If less than 2” on 12”, contact our factory.)<br />

SNAP-CLAD<br />

Finish:<br />

Air & Water Infiltration Tested:<br />

PAC-CLAD® (Kynar 500® or Hylar 5000®)<br />

ASTM E283/1680 and E331/1646<br />

Miami-Dade NOA & Florida<br />

Approvals:<br />

Note:<br />

Petersen Aluminum’s Snap-<strong>Clad</strong> Panel is thoroughly tested to meet the<br />

requirements of Miami-Dade and the Florida Building codes. Please refer to<br />

our website, www.pac-clad.com, for specific NOA & Florida Building Approvals<br />

available by gauge and building assembly.<br />

When a U.L. Rating is required, Petersen Aluminum Corporation must be<br />

notified prior to fabrication of the panels.<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

3


UL Construction No. 254<br />

Wind-Uplift - Class 90 (See Item No. 4) / Fire Not Investigated<br />

UL Construction No. 254<br />

1<br />

2<br />

3<br />

4<br />

<strong>Metal</strong> Roof Deck Panels*<br />

“Snap-<strong>Clad</strong>”<br />

Roof Deck Fasteners* (Panel Clips)<br />

“Snap-<strong>Clad</strong> Clip”<br />

Panel Fasteners (Screws)<br />

Purlins<br />

No. 22 MSG or No. 24 MSG min. thickness coated steel panels. Panels<br />

12 in. wide max., 10 in. wide min. 1-3/4 in. high at the ribs. Panels<br />

continuous over two or more spans. A bead of sealant may be used at<br />

panel side joints.<br />

One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. One panel clip<br />

located at each purlin intersection.<br />

Fasteners used to attach panel clips (item 2) to purlins to be No. 10-16<br />

by 1 in. long No. 3 self-drilling point, No. 2 Phillips drive head, cadmium<br />

plated steel screws. Two screws per clip to be used, inserted through<br />

1/4 in. diameter guide holes.<br />

No. 16 MSG min. thickness steel (50,000 psi min. yield strength).<br />

Spacing:<br />

For 22 MSG thickness panels - 60 in. OC<br />

For 24 MSG thickness panels - 48 in. OC<br />

*Bearing the UL Classification Marking<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

4<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


UL Construction No. 255<br />

Wind-Uplift - Class 90 and 60 (See Item No. 4) / Fire Not Investigated<br />

1<br />

2<br />

3<br />

4<br />

<strong>Metal</strong> Roof Deck Panels*<br />

“Snap-<strong>Clad</strong>”<br />

Roof Deck Fasteners* (Panel Clips)<br />

“Snap-<strong>Clad</strong> Clip”<br />

Panel Fasteners (Screws)<br />

Purlins<br />

No. 24 MSG min. thickness coated steel. Panels 18 in. wide max., 10 in.<br />

wide min. 1-3/4 in. high at the ribs. Panels continuous over two or more<br />

spans. A bead of sealant may be used at panel side joints.<br />

One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. One panel clip<br />

located at each purlin intersection.<br />

Fasteners used to attach panel clips (item 2) to purlins to be No. 10-16<br />

by 1 in. long cadmium plated pancake head No. 2 phillips drive, No. 3<br />

self-drilling point steel screws. Two screws per clip to be used inserted<br />

through 1/4 in. diameter guide holes.<br />

No. 16 MSG min. thickness steel (50,000 psi min. yield strength).<br />

Spacing for Class 90 to be 48 in. OC: For Class 60 to be 60 in. OC<br />

UL Construction No. 255<br />

*Bearing the UL Classification Marking<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

5


UL Construction No. 261<br />

Wind-Uplift - Class 90 or 60 (See Item No. 4) / Fire Not Investigated<br />

UL Construction No. 261<br />

1<br />

2<br />

3<br />

4<br />

<strong>Metal</strong> Roof Deck Panels*<br />

“Snap-<strong>Clad</strong>”<br />

Roof Deck Fasteners* (Panel Clips)<br />

“Snap-<strong>Clad</strong> Clip”<br />

Panel Fasteners (Screws)<br />

Purlins<br />

0.032 in. thick aluminum or No. 24 MSG min. thickness coated steel.<br />

Panels 10 in. wide. 1-3/4 in. high at the ribs. Panels continuous over two<br />

or more spans. A bead of sealant may be used at panel side joints.<br />

One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. One panel clip<br />

located at each purlin intersection.<br />

Fasteners used to attach panel clips (Item 2) to purlins to be No. 10-16<br />

by 1 in. long cadmium plated, pancake head, No. 2 phillips drive, No. 3<br />

self-drilling point. Two screws per clip to be used, inserted through 1/4<br />

in. diameter guide holes in clip base.<br />

No. 16 MSG min. thickness steel (50,000 psi min. yield strength).<br />

Spacing for aluminum panels:<br />

For Class 90 to be 36 in. OC.<br />

For Class 60 to be 48 in. OC.<br />

Spacing for steel panels:<br />

22 MSG thick to be 60 in. OC.<br />

24 MSG thick to be 48 in. OC.<br />

*Bearing the UL Classification Marking<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

6<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


UL Construction No. 303<br />

Uplift - Class 90 / Fire Not Investigated<br />

1<br />

<strong>Metal</strong> Roof Deck Panels * / “Snap-<strong>Clad</strong>”<br />

No. 24 MSG min thickness coated steel. Panel width 18 in. max.,<br />

10 in. min., 1-3/4 in. high at the ribs. A bead of sealant may be<br />

used at panel side joints.<br />

2<br />

3<br />

4<br />

5<br />

6<br />

A<br />

<strong>Metal</strong> Roof Deck Panels* (Not Shown)<br />

0.032 in. min thick aluminum, 16 in. wide max, 10 in.<br />

wide min, 1-3/4 in. high at the rib. A bead of sealant may<br />

be used at panel side joints.<br />

Roof Deck Fasteners* (Panel Clips) / “Snap-<strong>Clad</strong> Clip”<br />

One piece assembly, 3-1/2 in. wide, 1-7/8 in.. high. Clip spacing<br />

to be 48 in. max. OC for steel panels and 18 in. max. OC for<br />

aluminum panels. Clips to interface with Item 2A (bearing plate).<br />

A<br />

Bearing Plate* (Not Shown)<br />

To be used with “Snap-<strong>Clad</strong> Clips” only (Item 2). To be<br />

24 MSG thick coated steel, nom 4-5/8 in. wide by<br />

6 in. long.<br />

Panel Fasteners (Screws)<br />

Fasteners used to attach panel clips and bearing plates (Items 2 &<br />

2A) through rigid insulation and optional OSB and/or gypsum board<br />

and into light gauge steel deck (Item No. 5) to be No. 14 truss head<br />

type with No. 3 Phillips drive, self-drilling steel screws. Two screws<br />

per clip to be used, inserted through 1/4 in. diameter guide holes.<br />

Fasteners to penetrate liner panel 3/4 in. min.<br />

Foamed Plastic (Rigid Insulation)<br />

Min thickness 1 in., max thickness 4-1/2 in. Density to be a min of<br />

1.8 pcf.<br />

A<br />

B<br />

Oriented Strand Board (OSB) (Optional) (Not Shown)<br />

Located over foamed plastic (Item 4). Max thickness 7/16<br />

in. Note: Bearing plates not required when OSB is used.<br />

Gypsum Board (Optional)<br />

Max thickness 5/8 in. Located over liner panel (Item 5).<br />

Liner Panel<br />

Min thickness No. 22 MSG. Coated steel (33,000 psi) min yield<br />

strength min. depth 1-1/2 in., max. pitch 6 in., fabricated to various<br />

profiles.<br />

Underlayment (Not shown)<br />

One ply of 30 lb roofing felt or one layer of bituminous resin type<br />

water proofing membrane.<br />

UL Construction No. 303<br />

7<br />

Supports (Not Shown)<br />

Used to support liner panels, spaced per deck manufacturer’s<br />

specifications for uplift.<br />

*Bearing the UL Classification Marking<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

7


UL Construction No. 343<br />

Uplift - Class 90 / Fire Not Investigated<br />

UL Construction No. 343<br />

1<br />

2<br />

3<br />

4<br />

5<br />

<strong>Metal</strong> Roof Deck Panels* / “Snap-<strong>Clad</strong>”<br />

No. 24 MSG min. coated steel panels 18 in. wide max., 10 in.<br />

wide min., 1-3/4 in. high at the ribs. A bead of sealant may be<br />

used at panel side joints.<br />

Roof Deck Fasteners* (Panel Clips) / “Snap-<strong>Clad</strong> Clip”<br />

One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. Clips spaced<br />

36 in. OC, max, fastened to plywood deck.<br />

Panel Fasteners (Screws)<br />

Fasteners used to attach panel clips (Item 2) to plywood to<br />

be No. 10-12 by 1 in. long pancake head, No. 2 Phillips drive,<br />

A-point, coated steel screw. Min two fasteners per clip to used.<br />

Underlayment<br />

Underlayment used over plywood deck to be Type 15 or<br />

30 organic felt. Sides overlapped min. 2 in., end laps per<br />

manufacturer’s instructions. Felt nailed to plywood deck with<br />

1-1/4 in. long steel cap nails, located per manufacturer’s<br />

instructions. Nail spacing to be max 12 in. OC at the side lap<br />

and max 24 in. OC in interior rows.<br />

As An Alternate: A self-adhering modified bitumen water<br />

proofing membrane may be used, installed per manufacturer’s<br />

instructions. Note: when alternate is used the plywood joints<br />

need not be sealed.<br />

Plywood Decking<br />

Plywood decking to be graded per PS83 specifications, 19/32<br />

in. thick, exposure 1, APA Rated Sheathing (42/20) square<br />

edged, Butt ends not blocked. All butt and side joints to be<br />

sealed with a one part urethane caulk sealant applied with<br />

a caulking gun and feathered outward from the joint. (Note<br />

exception under Item No. 4, alternate.)<br />

6<br />

7<br />

Supports (Not Shown)<br />

Spaced max of 24 in. OC. Any of the following types may be<br />

used to support the plywood decking:<br />

a) Nom. 2 by 6 in., No. 2 grade or better S-P-F, Hemlock Fir,<br />

Douglas Fir or Southern Yellow Pine or equivalent.<br />

b) Wood trusses with a nom. 2 by 4 in. upper chord of the<br />

same grade as item a.<br />

c) No. 22 MSG min cold formed coated steel (min. yield to be<br />

33,000 psi).<br />

Plywood Fasteners (Not Shown)<br />

Fasteners used to attach the plywood deck or OSB to the<br />

supports to be as follows:<br />

a) For plywood-to-wood supports No. 8-18 by 1-7/8 in. long<br />

bugle-head steel screws with a No. 2 Phillips drive, a<br />

“Hi-Low” thread pattern and an “S-Point”.<br />

b) As an alternate to Item a, 8d common nails may be used.<br />

c) For plywood-to-steel supports for a steel thickness less<br />

than No. 20 MSG No. 7-19 by 1-1/4 in. long bugle-head steel<br />

screws with a No. 2 Phillips head drive “Hi-Low” threads and an<br />

“S-Point”. For a steel thickness greater than No. 20 MSG to No.<br />

16 MSG, No. 6-20 by 1-1/4 in. long bugle-head steel screws<br />

with a No. 2 Phillips drive and a S12 (TEKS/3)supR point.<br />

Spacing: Fastener spacing for all fastener types to be 6 in. OC<br />

at the plywood edges and 12 in. OC in the interior.<br />

Refer to General Information, Roof Deck Construction (Building<br />

Materials Directory) for items not evaluated.<br />

*Bearing the UL Classification Marking<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

8<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


1.75” NOM.<br />

UL Construction No. 508<br />

Uplift - Class 90 / Fire Not Investigated<br />

16” MAX<br />

1.75” NOM.<br />

1<br />

2<br />

3<br />

1.75” NOM.<br />

4<br />

5<br />

24” MAX<br />

<strong>Metal</strong> Roof Deck Panels* / “Snap-<strong>Clad</strong>”<br />

0.032 in. min. thick aluminum; Panels 16 in. wide max., 10 in.<br />

wide min., 1-3/4 in. high at the rib. A bead of sealant may be<br />

used at panel side joints.<br />

Roof Deck Fasteners* (Panel Clips) / “Snap-<strong>Clad</strong> Clip”<br />

One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. Clips<br />

spaced 18 in. OC.<br />

Panel Fasteners (Screws)<br />

Fasteners used to attach panel clips (Item 2) to plywood (Item<br />

5) to be No. 10-12 by 1 in. long, No. 1 Phillips drive, bugle head<br />

coated steel wood screws. Two screws used per clip inserted<br />

through 1/4 in. diameter guide holes.<br />

Underlayment<br />

Underlayment used over plywood deck to be Type 30 organic<br />

felt. Sides overlapped min. 2 in., end laps per manufacturer’s<br />

instructions. Felt nailed to plywood deck with 1 in. long<br />

galvanized steel roofing nails, located per manufacturer’s<br />

18” Max. (Steel)<br />

instructions. Nail spacing to be max 12 in. OC at the side lap<br />

16” Max. (Alum.)<br />

and max 24 in. OC in interior rows.<br />

As An Alternate: A self-adhering modified bitumen water<br />

proofing membrane may be used, installed per manufacturer’s<br />

instructions. Note: when alternate is used the plywood joints<br />

need not be sealed.<br />

Plywood Decking<br />

Plywood decking to be graded per PS83 specifications, 19/32<br />

in. thick, exposure 1, APA rated sheathing (42/20) square<br />

edged, Butt ends not blocked.<br />

6<br />

7<br />

Supports<br />

Spaced max 24 in. OC. Any of the following types may be used<br />

to support the plywood decking:<br />

a) 2 by 6 in., min No. 2 grade A.F.P.A. S-P-F Hemlock Fir,<br />

Douglas Fir or Southern Pine or equivalent.<br />

b) Wood trusses with a nominal 2 by 4 in. upper chord of the<br />

same grade as item a.<br />

c) No. 22 MSG min thick cold formed coated steel (min. yield to<br />

be 33,000 psi).<br />

Plywood Fasteners<br />

(Not shown) Fasteners used to attach the plywood deck to the<br />

supports to be as follows:<br />

a) For plywood-to-wood supports No. 8-18 by 1-7/8 in. long<br />

bugle-head steel screws with a No. 2 Phillips drive, a “Hi-Low”<br />

thread pattern and an “S-Point”.<br />

b) As an alternate to Item a, 8d by 2-1/2 in. long deformed<br />

shank common nails may be used.<br />

c) For plywood-to-steel supports for a steel thickness less<br />

than No. 20 MSG, No. 7-19 by 1-1/4 in. long bugle-head steel<br />

screws with a No. 2 Phillips head drive “Hi-Low” threads and<br />

an “S-Point”. For a steel thickness greater than No. 20 MSG<br />

to No. 16 MSG, No. 6-20 by 1-1/4 in. long bugle-head steel<br />

screws with a No. 2 Phillips drive and a S12 (TEKS/3)® point.<br />

Spacing: Fastener spacing for all fastener types to be 6 in. OC<br />

at the plywood edges and 12 in. OC in the interior.<br />

Refer to General Information, Roof Deck Construction (<strong>Roofing</strong><br />

Materials and Systems Directory) for items not evaluated.<br />

*Bearing the UL Classification Marking<br />

UL Construction No. 508<br />

1.75” NOM.<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

9


UL Construction No. 508A<br />

Uplift - Class 90 / Fire Not Investigated<br />

18" MAX. (STEEL)<br />

16" MAX. (ALUM.)<br />

UL Construction No. 508A<br />

1<br />

2<br />

3<br />

4<br />

5<br />

<strong>Metal</strong> Roof Deck Panels* / “Snap-<strong>Clad</strong>”<br />

No. 24 MSG min. thick coated steel panels, 18 in. wide max.,<br />

10 in. wide min., or 0.032 in. min. thick aluminum, 16 in. wide<br />

max., 10 in. wide min., 1 3/4 in. high at the rib. A bead of<br />

sealant may be used at panel side joints.<br />

Roof Deck Fasteners* (Panel Clips) / “Snap-<strong>Clad</strong> Clip”<br />

One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. Clips<br />

spaced 36 in. OC max for steel panels and 18 in. OC max for<br />

aluminum panels. Fastened to nailable insulation (Item 5).<br />

Fasteners (Screws)<br />

Fasteners used to attach panel clip (Item 2) to nailable<br />

insulation (Item 5) to be No. 10-12 by 1 in. long pancake head,<br />

No. 2 Phillips drive, A-point coated steel screws. Min. two<br />

fasteners per clip.<br />

Underlayment<br />

Underlayment used over nailable insulation (Item 5) to be<br />

Type 30 organic felt. Sides overlapped min. 2 in. End laps per<br />

manufacturer’s instructions. Felt nailed to nailable insulation<br />

with 1 in. long galvanized steel roofing nails, located in side<br />

laps and between side lap per manufacturer’s instructions. Nail<br />

spacing to be max 12 in. OC at the side lap and max 24 in. OC<br />

in interior rows.<br />

Nailable Insulation<br />

Consisting of 1 in. min. to 3-1/2 in. max thick Classified<br />

polyisocyanurate foamed plastic with a factory laminated 7/16<br />

in. thick APA rated O.S.B. Density of foamed plastic to be 2 pcf.<br />

5<br />

7<br />

8<br />

7<br />

8<br />

9<br />

2<br />

1<br />

3<br />

4<br />

5<br />

1.750 NOM.<br />

Fasteners (Screws)<br />

Fasteners used to attach nailable insulation (Item 5) to liner<br />

panel (Item 8) to be No. 11-13, No. 3 Phillips drive, truss head,<br />

painted steel screws. Length to depend on overall thickness of<br />

deck and to penetrate steel deck 1/2 in. min. A 2 in. diameter<br />

formed pressure plate fabricated from No. 22 MSG coated steel<br />

to be used with each screw. Fasteners located in three rows<br />

along the 8 ft. length of the nailable insulation beginning 6 in.<br />

from the 8 ft. edges with a row down the center and spaced<br />

21 in. OC beginning 6 in. from the 4 ft. edges. A total of 15<br />

fasteners used for each 4 by 8 ft. board.<br />

Liner Panel (Steel Deck)<br />

No. 22 MSG min. thick coated steel. Min. depth 1-1/2 in., max<br />

pitch 6 in. fabricated to various profiles. Min. yield strength<br />

33,000 psi. Fastened to supports (Item 6) with fastener type and<br />

spacing per liner panel manufacturer’s instructions for<br />

uplift loading.<br />

Gypsum Board (Optional - Not Shown)<br />

Max. thick 5/8 in. supplied in 4 by 8 ft. sheets. Butt joints<br />

located over crests of metal roof deck panel (Item 1). Fastened<br />

to panel with same fasteners used for nailable insulation<br />

(Item 5).<br />

Refer to General Information, Roof Deck Construction (<strong>Roofing</strong><br />

Materials and Systems Directory) for items not evaluated.<br />

6<br />

Supports (Purlins)<br />

Purlins used for liner panel (Item 8) support to be cold formed<br />

steel sections. As alternatives, structural steel components (hot<br />

rolled beams, channels, open web joists, etc.) may be used.<br />

Min. gauge and yield to depend on design considerations for<br />

uplift loading with max spacing to be 6 ft. OC.<br />

*Bearing the UL Classification Marking<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

10<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


1.75” NOM.<br />

UL Construction No. 614<br />

Uplift - Class 90 / Fire Not Investigated<br />

16” MAX<br />

1.75” NOM.<br />

1<br />

2<br />

3<br />

1.75” NOM.<br />

4<br />

5<br />

6<br />

<strong>Metal</strong> Roof Deck Panels* / “Snap-<strong>Clad</strong>”<br />

16 in. wide max., 10 in. wide min., 1-3/4 in. high at the rib,<br />

fabricated from 16 oz., half-hard copper. A bead of sealant<br />

may be used at panel side joints.<br />

Roof Deck Fasteners* (Panel Clips) / “Snap-<strong>Clad</strong> Clip”<br />

One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. The clips are<br />

to be spaced a maximum of 24 in. OC.<br />

Panel Fasteners (Screws)<br />

Fasteners used to attach panel clips (Item 2) to plywood (Item<br />

5) to be No. 10-16 by 1 in. long, No. 1 in. pancake head coated<br />

stainless steel screws. Two screws used per clip inserted<br />

through 1/4 in. diameter guide holes.<br />

Underlayment*<br />

Any UL Classified base or ply sheet, mechanically fastened with<br />

nails or staples.<br />

A Underlayment: Rosin paper, 9 mil. thick, mechanically<br />

18” Max. (Steel)<br />

fastened with nails or staples.<br />

16” Max. (Alum.)<br />

24” MAX<br />

Plywood Decking<br />

Plywood decking to be graded per PS83 specification, 19/32<br />

in. thick, Grade B-C, exposure 1, APA rated sheathing (42/20)<br />

square edged. All plywood joints to be sealed against leakage<br />

with caulk or a one part urethane sealant.<br />

Supports<br />

Spaced max 24 in. OC. Any of the following types may be used<br />

to support the plywood decking:<br />

a) 2 by 6 in., min. No. 2 grade A.F.P.A. S-P-F Hemlock Fir,<br />

Douglas Fir or Southern Pine or equivalent.<br />

b) Wood trusses with a nominal 2 by 4 in. upper chord of the<br />

same grade as item a.<br />

7<br />

c) No. 22 MSG min. thick cold formed coated steel (min. yield<br />

to be 33,000 psi).<br />

Plywood Fasteners (Not shown)<br />

Fasteners used to attach the plywood deck (Item 5) to the<br />

supports (Item 6) to be as follows:<br />

a) For plywood-to-wood supports, No. 8-18 by 1-7/8 in. long<br />

bugle-head steel screws with a No. 2 Phillips drive, a “Hi-Low”<br />

thread pattern and an “S-Point”.<br />

b) As an alternate to Item a, 8d by 2-1/2 in. long deformed<br />

shank common nails may be used.<br />

c) For plywood-to-steel supports for a steel thickness less<br />

than No. 20 MSG, No. 7-19 by 1-1/4 in. long bugle-head steel<br />

screws with a No. 2 Phillips head drive “Hi-Low” thread and an<br />

“S-Point.” For a steel thickness greater than No. 20 MSG to No.<br />

16 MSG, No. 6-20 by 1-1/4 in. long bugle-head steel screws<br />

with a No. 2 Phillips drive and a S12 (TEKS/3)® point.<br />

Spacing: Fastener spacing for all fastener types to be 6 in. OC<br />

at the plywood edges and 12 in. OC in the interior.<br />

Refer to General Information, Roof Deck Construction (<strong>Roofing</strong><br />

Materials and Systems Directory) for items not evaluated.<br />

*Bearing the UL Classification Marking<br />

UL Construction No. 614<br />

1.75” NOM.<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

11


UL Construction No. 790<br />

Class A<br />

Coated Steel and aluminum panels identified as Snap-On Standing Seam, High Snap-On Standing Seam,<br />

Snap-On Batten, Integral Batten, Redi-Roof Batten, Redi-Roof Standing Seam, Snap-<strong>Clad</strong>, Integral<br />

Standing Seam, Tite-Loc and Tite-Loc Plus.<br />

UL Construction No. 790<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

Deck:<br />

Incline:<br />

Barrier Board:<br />

Ply Sheet (optional):<br />

Surfacing:<br />

Deck:<br />

Incline:<br />

Barrier Board:<br />

Ply Sheet (optional):<br />

Surfacing:<br />

Deck:<br />

Incline:<br />

Barrier Board:<br />

Ply Sheet (optional):<br />

Surfacing:<br />

Deck:<br />

Incline:<br />

Barrier Board:<br />

Ply Sheet (optional):<br />

Surfacing:<br />

Deck:<br />

Incline:<br />

Surfacing:<br />

Deck:<br />

Incline:<br />

Barrier Board:<br />

Ply Sheet (optional):<br />

Surfacing:<br />

NC<br />

No Limitations<br />

1/4 in. min. Georgia <strong>Pac</strong>ific Corp. Dens-Deck Overlayment Board<br />

Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified<br />

prepared roofing accessory or WR Grace “Ice and Water Shield”<br />

Steel or aluminum roofing panels, mechanically fastened<br />

NC<br />

No Limitations<br />

5/8 in min. plywood<br />

Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified<br />

prepared roofing accessory or WR Grace “Ice and Water Shield”<br />

Steel roofing panels mechanically fastened<br />

NC<br />

No Limitations<br />

7/16 OSB or 5/8 in. plywood over polyisocyanurate insulation board or polyisocyanurate<br />

composite board, any thickness<br />

Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified<br />

prepared roofing accessory or WR Grace “Ice and Water Shield”<br />

Steel or aluminum roofing panels mechanically fastened<br />

NC<br />

No Limitations<br />

Polyisocyanurate, glass fiber, perlite or wood fiber, any thickness<br />

Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified<br />

prepared roofing accessory or WR Grace “Ice and Water Shield”<br />

Steel or aluminum roofing panels mechanically fastened<br />

NC<br />

No Limitations<br />

Steel roofing panels mechanically attached to metal purlins<br />

C-15/32<br />

No Limitations<br />

Georgia <strong>Pac</strong>ific Corp. 1/4 in. (min.) Dens-Deck with all joints staggered a min. of 6 in. from the<br />

plywood joints<br />

Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified<br />

prepared roofing accessory or WR Grace “Ice and Water Shield”<br />

Steel or aluminum roofing panels mechanically fastened<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

12<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


UL Construction No. 263<br />

<strong>Metal</strong> Roof Deck Panels / File R14293<br />

Mechanically Attached <strong>Metal</strong> Roof Panels<br />

1<br />

2<br />

3<br />

Mechanically Attached<br />

<strong>Metal</strong> Roof Panels<br />

For use in Design Numbers:<br />

Mechanically Attached<br />

<strong>Metal</strong> Roof Panels<br />

For use in Design Numbers:<br />

Mechanically Attached <strong>Metal</strong><br />

Roof Panels<br />

For use in Design Numbers:<br />

Type “Snap-<strong>Clad</strong>” roof deck panels (No. 24 MSG min gauge coated steel or 0.032<br />

min. gauge coated aluminum) placed over specified insulation and/or roof covering<br />

for respective designs. Type “Snap-<strong>Clad</strong>” panels are secured by “Snap-<strong>Clad</strong> Clips”<br />

with the upper portion of the clip engaging the panel rib. A 4-1/2 by 6 in. bearing<br />

plate fabricated from No. 26 MSG coated steel is used under each panel clip (the<br />

bearing plate shall be placed over the specified insulation). Panel clips are attached<br />

to the steel deck with No. 14 steel screws having a No. 3 Phillips-drive truss head<br />

with an off-set drill-type point. Two fasteners per clip are used.<br />

P225, P227, P230, P233, P237, P259, P508, P510, P512, P514, P701, P711, P717,<br />

P720, P722, P723, P724, P726, P731, P734, P736, P801, P815, P819 and P821.<br />

Types “High Snap-On Standing Seam”, “Snap-On Standing Seam”, “Integral<br />

Batten”, “Integral Standing Seam”, “Redi-Roof Standing Seam”, “Redi-Roof Batten”,<br />

“Snap-<strong>Clad</strong>”, “Tite-Loc”, “Tite-Loc Plus” roof deck panels (No. 24 MSG min. gauge<br />

coated steel or 0.032 min. gauge coated aluminum) placed over specified insulation<br />

and/or roof covering for respective designs. Panels secured to a top layer of<br />

7/16 in. APA-Rated oriented stand board (OSB) laminated to rigid insulation or 5/8<br />

in. plywood over rigid insulation. Panels secured to oriented strand board or plywood<br />

at side ribs with panel clips designed specifically for these panels. Panel clips<br />

spaced 18 in. OC using No. 10 by 1-1/4 in. long self-drilling, self tapping wafer head.<br />

Zinc-plated carbon steel screws. The oriented strand board laminated insulation or<br />

plywood covered rigid insulation are mechanically fastened to steel roof deck and<br />

covered with a 30 lb. felt.<br />

P225, P227, P230, P233, P237, P259, P263, P508, P510, P512, P514, P515, P701,<br />

P711, P717, P720, P722, P723, P724, P726, P731, P734, P736, P801, P815, P819<br />

and P821.<br />

Types “Tite-Loc” and “Tite-Loc Plus” roof deck panels (No. 24 MSG min. gauge<br />

coated steel or 0.032 min. gauge coated aluminum) placed over specified insulation<br />

and/or roof covering for respective designs. Both types secured to hat sections+ or<br />

bearing plates++ with panel clips designed for the particular panel.<br />

P225, P227, P230, P233, P237, P508, P510, P512, P701, P711, P715, P717, P720,<br />

P722, P724, P726, P731, P734, P736, P801, P815, P819, P821<br />

+Hat-shaped member to be a minimum of 16 MSG, 1 in. min. depth. Member to be fastened through<br />

the roof insulation to the steel roof deck with No. 14 self-drilling and/or self-tapping fasteners. Spacing<br />

to be determined by the structural loading requirements. In addition, any compressible UL Classified<br />

glass fiber compressible blanket insulation with or without a vapor retarding facing may be used<br />

between the specified roof insulation and the metal roof panels.<br />

UL Construction No. 263<br />

++Bearing plate to be a minimum of 16 MSG. Member to be fastened through the roof insulation to<br />

the steel deck with No. 14 self-drilling and/or self-tapping fasteners.<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

13


UL Construction Code<br />

Maximum Clip Spacing<br />

Substrates<br />

Rigid Insulation Over<br />

UL Construction Code<br />

Gauge<br />

22 GA<br />

24 GA<br />

0.032<br />

0.040<br />

16 Oz. Copper<br />

1<br />

2<br />

3<br />

10”<br />

Width<br />

18”, 16”, 12”, 10”<br />

18”, 16”, 12”, 10”<br />

10”<br />

12”, 10”<br />

18”, 16”, 12”, 10”<br />

18”, 16”, 12”, 10”<br />

10”<br />

16”, 12”, 10”<br />

16”, 12”, 10”<br />

10”<br />

16”, 12”, 10”<br />

16”, 12”, 10”<br />

16”, 12”, 10”<br />

Open Frame Purlins<br />

UL 261 (5’-0”)<br />

UL 255 (4’-0”)<br />

UL 261 (4’-0”)<br />

UL 254 (4’-0”)<br />

UL 255 (4’-0”)<br />

UL 261 (3’-0”)<br />

UL 261 (3’-0”)<br />

5/8” Plywood<br />

UL 343 (3’-0”)<br />

UL 343 (3’-0”)<br />

UL 508 (1’-6”)<br />

UL 508 (1’-6”)<br />

UL 614 (2’-0”)<br />

Contact Petersen Aluminum Corporation for complete UL construction assemblies.<br />

22 GA Steel Deck<br />

With Bearing Plates<br />

UL 508A (3’-0”)<br />

UL 303 (4’-0”)<br />

UL 303 (4’-0”)<br />

UL 508A (3’-0”)<br />

UL 303 (1’-6”)<br />

UL 508A (1’-6”)<br />

UL 303 (1’-6”)<br />

UL 508A (1’-6”)<br />

For complete information regarding appropriate purlin spacing, contact Petersen Aluminum Corporation directly.<br />

Insulation thicknesses varies between 1” and 4-1/2” according to R-value desired. Refer to UL <strong>Roofing</strong> Materials directly.<br />

SNAP-CLAD MIAMI-DADE NOA’S & FLORIDA APPROVALS<br />

Petersen Aluminum’s Snap <strong>Clad</strong> panel is thoroughly tested to meet the requirements of Miami-Dade and<br />

Florida Building codes. Please refer to our website, www.pac-clad.com, for specific NOA’s and Florida<br />

Building Approvals available by gauge and building assembly.<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

14<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


Hip/Ridge Detail<br />

Job Name:<br />

SNAP-CLAD Flashing Details<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

15


Eave Detail<br />

SNAP-CLAD Flashing Details<br />

Job Name:<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

16<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


Eave Detail<br />

Job Name:<br />

SNAP-CLAD Flashing Details<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

17


Eave Detail<br />

SNAP-CLAD Flashing Details<br />

Job Name:<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

18<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


Valley Detail<br />

Job Name:<br />

SNAP-CLAD Flashing Details<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

19


Peak Detail<br />

SNAP-CLAD Flashing Details<br />

Job Name:<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

20<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


Outside Corner Detail<br />

Job Name:<br />

SNAP-CLAD Flashing Details<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

21


Inside Corner Detail<br />

SNAP-CLAD Flashing Details<br />

Job Name:<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

22<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


Rake Detail<br />

Job Name:<br />

SNAP-CLAD Flashing Details<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

23


Head Wall Detail<br />

SNAP-CLAD Flashing Details<br />

Job Name:<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

24<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


Pitch Break Detail<br />

Job Name:<br />

SNAP-CLAD Flashing Details<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

25


Gable Detail<br />

SNAP-CLAD Flashing Details<br />

Job Name:<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

26<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


Fascia/Rake Wall Detail<br />

Job Name:<br />

SNAP-CLAD Flashing Details<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

27


Gutter Detail<br />

SNAP-CLAD Flashing Details<br />

Job Name:<br />

SNAP-CLAD Flashing Details<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

28<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


Sill Detail<br />

Job Name:<br />

SNAP-CLAD Flashing Details<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

29


Fascia to Soffit Transition<br />

SNAP-CLAD Flashing Details<br />

Job Name:<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

30<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


Fascia to Soffit Transition<br />

Job Name:<br />

SNAP-CLAD Flashing Details<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

31


Gravel Stop/Head Detail<br />

SNAP-CLAD Flashing Details<br />

Job Name:<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

32<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


Vented Ridge Detail<br />

Job Name:<br />

SNAP-CLAD Flashing Details<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

33


SNAP-CLAD Flashing Details<br />

Job Name:<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

34<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


Job Name:<br />

SNAP-CLAD Flashing Details<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

35


SNAP-CLAD Flashing Details<br />

Job Name:<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

36<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


Bearing Plate Assembly<br />

Job Name:<br />

SNAP-CLAD Flashing Details<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

37


SNAP-CLAD Flashing Details<br />

Job Name:<br />

Date:<br />

Contractor:<br />

Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

38<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935


SPEC DATA ®<br />

Roof & Wall Panels 07 41 00<br />

Petersen Aluminum Corporation<br />

1. Product Name<br />

• TITE-LOC, TITE-LOC HS and TITE-LOC<br />

Plus Mechanically Seamed Panels<br />

• SNAP-CLAD Standing Seam Panels<br />

• Snap-On and High Snap-On Standing<br />

Seam Panels<br />

• Redi-Roof and Redi-Roof Batten Standing<br />

Seam Panels<br />

• Integral Standing Seam and Integral<br />

Batten Panels<br />

• Flush Panels<br />

• PAC-750 and PAC-850 Soffit Panels<br />

• Exposed Fastener Panels<br />

• Precision Series Horizontal Wall Panel<br />

2. Manufacturer<br />

Petersen Aluminum Corp.<br />

1005 Tonne Rd.<br />

Elk Grove Village, IL 60007<br />

(847) 228-7150<br />

(800) 323-1960<br />

Fax: (800) 722-7150<br />

www.pac-clad.com<br />

3. Product Description<br />

Basic Use<br />

Petersen Aluminum produces a wide variety<br />

of wall and soffit panels in addition to a complete<br />

line of metal roofing panels. All standing<br />

seam panels are corrective leveled. Standing<br />

seam, flush, exposed fastener panels and<br />

wall and soffit panels are all factory formed in<br />

continuous lengths up to 50’. Check specific<br />

profile for maximum panel length and consult<br />

with local factory for longer lengths. Matching<br />

flashing and trim can be factory or field<br />

formed from PAC-CLAD material.<br />

Materials and Finishes<br />

PAC-CLAD is a versatile prefinished sheet<br />

metal coating (Kynar 500 ® or Hylar 5000 ® ) that<br />

is applied to G90 galvanized steel, galvalume<br />

steel, or prime quality aluminum. Originally<br />

developed for use in abrasive environments,<br />

PAC-CLAD is ideally suited for roofing,<br />

curtainwall, storefront and trim applications.<br />

TITE-LOC, TITE-LOC HS and TITE-LOC Plus<br />

• 24 gauge PAC-CLAD G-90 galvanized steel<br />

• 22 gauge PAC-CLAD Galvalume steel<br />

• .032 PAC-CLAD prime quality aluminum<br />

• .040 PAC-CLAD prime quality aluminum<br />

• 24 gauge Galvalume ® Plus<br />

SNAP-CLAD Panels<br />

• 24 gauge PAC-CLAD G-90 galvanized steel<br />

• 22 gauge PAC-CLAD Galvalume steel<br />

• .032 PAC-CLAD prime quality aluminum<br />

• .040 PAC-CLAD prime quality aluminum<br />

• 16 oz cold-rolled copper<br />

• 24 gauge Galvalume ® Plus<br />

Snap-On and High Snap-On Panels<br />

• 24 gauge PAC-CLAD G-90 Galvanized steel<br />

• .032 PAC-CLAD prime quality aluminum<br />

• 24 gauge Galvalume ® Plus<br />

Redi-Roof and Redi-Roof Batten Panels<br />

• 24 gauge PAC-CLAD G-90 galvanized steel<br />

• 22 gauge PAC-CLAD Galvalume steel<br />

• .032 PAC-CLAD prime quality aluminum<br />

• 16 oz cold-rolled copper<br />

• 24 gauge Galvalume ® Plus<br />

Integral Panels<br />

• 24 gauge PAC-CLAD G-90 Galvanized Steel<br />

• .032 PAC-CLAD prime quality aluminum<br />

• 24 gauge Galvalume® Plus<br />

Flush Panels<br />

• 24 gauge PAC-CLAD G-90 galvanized steel<br />

• 22 gauge PAC-CLAD Galvalume steel<br />

• .032 PAC-CLAD prime quality aluminum<br />

• .040 PAC-CLAD prime quality aluminum<br />

• 24 gauge Galvalume® Plus<br />

PAC-750 and PAC-850 Soffit Panels<br />

• .032 PAC-CLAD prime quality aluminum<br />

Exposed Fastener Panels<br />

• 24 gauge PAC-CLAD G-90 galvanized steel<br />

• 22 gauge PAC-CLAD Galvalume steel<br />

• .032 PAC-CLAD prime quality aluminum<br />

• .040 PAC-CLAD prime quality aluminum<br />

• .050 PAC-CLAD prime quality aluminum<br />

• 24 gauge Galvalume® Plus<br />

TYPES<br />

TITE-LOC,TITE-LOC Plus and TITE-LOC HS<br />

Panels<br />

TITE-LOC panels combine structural performance<br />

with architectural panel aesthetics.<br />

A factory-applied sealant bead offers<br />

additional weather resistance. The minimum<br />

panel length is 4’ (1.2 m). TITE-LOC panels<br />

feature a 2” (51 mm) leg height that requires<br />

mechanical field seaming after installation.<br />

Panels include a concealed fastener floating<br />

clip system designed to allow for thermal<br />

expansion/contraction.<br />

All three panels carry a UL 90 classification<br />

over a wide variety of substrates and assemblies,<br />

including 5/8” (15.9 mm) plywood,<br />

purlins and rigid insulation in conjunction<br />

with bearing plates (UL design numbers 90,<br />

176, 180 238B, 437, 449, 451, 452, 487, 616,<br />

and 617).<br />

TITE-LOC and TITE-LOC HS panels are factory<br />

formed to length and field-seamed to a<br />

90 degree lock, while TITE-LOC Plus panels<br />

are designed to be field-seamed to a 180 degree<br />

lock.<br />

TITE-LOC panels are designed for application<br />

on roof slopes as low as 1/2:12 pitch.<br />

The TITE-LOC seamer is bi-directional, offering<br />

labor savings to travel up and down<br />

slope. 6:12 roof pitch is the maximum the<br />

Tite-Loc seamer will travel upslope. The<br />

TITE-LOC Plus seamer runs in one direction<br />

only and care should be taken to install panels<br />

from left to right to ensure the seamer<br />

travels downslope. The seamer will not run<br />

up slope on a roof pitch greater than 4:12.<br />

The 90 degree TITE-LOC can be fieldcurved<br />

to a minimum radius of 20’. Contact<br />

local factory for more details about curving<br />

capabilities. Additional features include:<br />

• Weathertighness warranty available<br />

• Available in four panel condition variations,<br />

check with local factory for striation<br />

and pencil rib availability<br />

• Corrective leveled<br />

SNAP-CLAD Panels<br />

Offering architectural panel aesthetics, as<br />

well as structural panel performance, SNAP-<br />

CLAD panels feature a 1 3/4” (44.5 mm) leg<br />

height and a continuous interlock for improved<br />

structural performance. A factoryapplied<br />

sealant bead provides additional<br />

weather resistance. The minimum panel<br />

length is 4’ (1.2 m).<br />

A concealed fastener clip system allows for<br />

thermal expansion/contraction while providing<br />

extraordinary hold-down strength. Two<br />

clips are available: a standard clip for most<br />

mansard and fascia applications and a highperformance<br />

clip for roofing application and<br />

UL 90 rated assemblies. SNAP-CLAD panels<br />

carry a UL 90 classification over a wide<br />

variety of substrates and assemblies, including<br />

5/8” (15.9 mm) plywood, purlins and<br />

rigid insulation in conjunction with bearing<br />

plates (UL design numbers 254, 255, 261,<br />

303, 343, 508, 508A, and 614). A minimum<br />

slope of 2:12 pitch is recommended on most<br />

applications. Additional features include:<br />

• Continuous interlock<br />

• Labor-saving one-piece design<br />

• Striations and factory eave notching<br />

• Stiffener beads<br />

• Weathertightness Warranty Available<br />

Snap-On and High Snap-On Panels<br />

These panels are designed for use in roofing,<br />

mansard and fascia applications and<br />

should be installed over a waterproofed solid<br />

substrate with a minimum 3:12 roof pitch.<br />

Factory roll formed in continuous lengths,<br />

Snap-On panels are ideal for specification<br />

on applications where roof transitions are<br />

required. The simplicity of the pan design,<br />

®<br />

SPEC-DATA<br />

SPEC-DATA® is a registered trademark of Reed Elsevier Inc. The manufacturer is responsible for technical accuracy. ©2007 Reed Construction Data.<br />

All Rights Reserved.<br />

39


®<br />

SPEC-DATA<br />

combined with inline tension leveling, provides<br />

superior flatness and allows for greater<br />

workability onsite.<br />

Both panels in steel carry a UL 90 rating for<br />

wind uplift when fastened to a solid substrate,<br />

including 5/8” (15.9 mm) plywood or<br />

OSB laminated to rigid insulation (UL design<br />

numbers 351 and 352). This is one of the few<br />

UL 90 systems that does not require sealant<br />

between plywood boards.<br />

The 1” (25.4 mm) Snap-On standing seam<br />

panel can now be curved to a concave or<br />

convex radius, with a minimum radius of 9’<br />

(2.7 m). This panel is ideal for barrel vaults<br />

and entranceways. Curved panels must<br />

be installed over a waterproofed solid substrate.<br />

The High Snap-On profile features a<br />

1 1/2” (38.1 mm) standing seam. Unlike the<br />

Snap-On panel, this panel cannot be curved.<br />

Additional features include:<br />

• Stiffener beads available<br />

Redi-Roof and Redi-Roof Batten Panels<br />

This architectural metal roofing system, which<br />

is available exclusively from Petersen Aluminum,<br />

may be specified in either batten or<br />

standing seam profile and is intended for application<br />

over a solid substrate with a minimum<br />

3:12 roof pitch. The minimum panel length is<br />

4’ (1.2 mm).<br />

Steel Redi-Roof panels carry a UL 90 rating for<br />

wind uplift when fastened to a solid substrate,<br />

including 5/8” (15.9 mm) plywood or OSB laminated<br />

to rigid insulation (UL design numbers<br />

350, 353 and 615). Additional features include:<br />

• Labor-saving one-piece design<br />

• Factory eave notching<br />

• Stiffener beads<br />

Integral Standing Seam and Integral<br />

Batten Panels<br />

PAC-CLAD Integral panels are designed for<br />

roofing applications, mansards, canopies<br />

and fascia. The one-piece design of the Integral<br />

panels minimizes labor and allows for<br />

quick and easy installation. The minimum<br />

panel length is 4’ (1.2 mm).<br />

Steel PAC-CLAD Integral panels carry a UL<br />

90 classification for wind uplift when fastened<br />

to a solid substrate, including 5/8”<br />

(15.9 mm) plywood or OSB laminated to rigid<br />

insulation (UL design numbers 346 and 347).<br />

Flush Panels<br />

PAC-CLAD Flush panels are designed for<br />

use in wall, fascia and soffit applications<br />

where a flush or flat appearance is desired.<br />

A rounded interlock leg and concealed fastening<br />

system improve the flush appearance<br />

while providing additional strength.<br />

These panels are not intended for use in roofing<br />

or mansard applications. Panels are factory-formed<br />

to length to minimize field cutting.<br />

The minimum panel length is 4’ (1.2 m). The<br />

maximum panel length is 28’ (8.4 m).<br />

The Flush panels are available with optional<br />

stiffening beads, which are recommended<br />

for longer panel lengths. One or two beads<br />

are available. Flush panels may also be<br />

specified for use as soffit panels. The soffit<br />

version of this panel is available with venting<br />

strips or perforated, in aluminum only, for increased<br />

air flow and under eave ventilation.<br />

Contact the local factory for venting options.<br />

Additional features include:<br />

• Rounded interlock leg providing improved<br />

flush fit<br />

PAC-750 and PAC-850 Soffit Panels<br />

PAC-750 preformed soffit panels are suitable<br />

for both commercial and residential<br />

use. PAC-850 soffit panels utilize an innovative<br />

hook and grab interlock. Both panels<br />

are rollformed of .032 gauge aluminum, and<br />

both panels are 12” (305 mm) wide with a<br />

“vee” groove every 6” (152 mm) center-tocenter.<br />

They are furnished in continuous<br />

lengths up to 20’ (6.1 m). Steel is not available<br />

in either profile.<br />

The PAC-750 and PAC-850 soffit panels<br />

can be perforated to allow for airflow and<br />

under eave ventilation. Both PAC-750 and<br />

PAC-850 can be specified as fully vented,<br />

half vented or solid. Petersen Aluminum can<br />

provide a soffit “J” channel as trim to match<br />

any of their soffit panels. “J” channel is available<br />

in lengths up to 12’ (3.7 m) in matching<br />

colors. Additional features include:<br />

• Perforation available for ventilation (PAC-<br />

750 and PAC-850)<br />

• Roll-formed to exact lengths<br />

Exposed Fastener Panels<br />

Petersen Aluminum offers a complete line of<br />

exposed fastener panels providing design<br />

flexibility, cost-effectiveness and aesthetics.<br />

The 7.2 Panel, R-36 Panel and 7/8” Corrugated<br />

Panels are ideal for a wide range of building<br />

envelope applications including roofs, walls,<br />

and linear panels. The R-41, M-42, M-36 and<br />

1/2” Corrugated panels are suitable for wall<br />

applications and equipment screens.<br />

The exposed fastener panels can also be<br />

produced perforated for a variety of exterior<br />

projects, such as equipment screens, or interior<br />

acoustical applications. Additional features<br />

include:<br />

• Matching screws and rivets<br />

• Closure strips available<br />

• Precut short lengths - 2’ (0.61 m) minimum<br />

Precision Series<br />

The PAC Precision Series Horizontal Wall Panels<br />

offer design flexibility, bold visual effect, cost<br />

effectiveness and easy installation. Two profiles<br />

are available: The HWP has a concealed extended<br />

screw leg and the HWPC utilizes a clip<br />

leg. Both panels can also be installed vertically<br />

in some applications, and can be specified as<br />

perforated for use in equipment screen applications.<br />

Maximum panel length is 35’.<br />

SIZES<br />

TITE-LOC, TITE-LOC HS and TITE-LOC<br />

Plus Panels<br />

• Width - 12”, 16”, 18” - (305, 406, 457 mm)<br />

• Height - 2” (51 mm)<br />

SNAP-CLAD Standing Seam Panels<br />

• Width - 10,” 12”, 16”, 18” - (254, 305, 406, 457 mm)<br />

• Height - 1 3/4” (44.5 mm)<br />

Snap-On Standing Seam Panels<br />

• Width - 12”, 18”, 19”, 20” (305, 457, 483, 508 mm)<br />

• Height - 1” (25.4 mm)<br />

Snap-On Batten Panels<br />

• Width - 11”, 12”, 18” (279, 305, 457 mm)<br />

• Height - 1 1/2” (38.1 mm)<br />

High Snap-On Panels<br />

• Width - 11”, 18,” 19” (279, 457, 483 mm)<br />

• Height - 1 1/2” (38.1 mm)<br />

Redi-Roof Standing Seam Panels<br />

• Width - 12”, 16”, 18” - (305, 406, 457 mm)<br />

• Height – 1 9/16” (40 mm) with offsets, 1<br />

3/8” (35 mm) without offsets<br />

Redi-Roof Batten Panels<br />

• Width - 12” (305 mm)<br />

• Height - 1 1/4” (32 mm)<br />

Integral Panels<br />

• Width - 11”, 12”, 18” (279, 305, 457 mm)<br />

• Height - 1 1/2” (38.1 mm)<br />

Flush Panels<br />

• Width - 7”, 11”, 12” (178, 279, 305 mm)<br />

• Height - 1” (25.4 mm)<br />

PAC-750 and PAC-850 Soffit Panels<br />

• Width - 12” (305 mm)<br />

M-42 Exposed Fastener Panels<br />

• Width - 42” (1067 mm)<br />

• Height - 3/4” (19.1 mm)<br />

M-36 Exposed Fastener Panels<br />

• Width - 36” (914 mm)<br />

• Height - 3/4” (12.7 mm)<br />

R-41 Exposed Fastener Panels<br />

• Width - 41” (1041 mm)<br />

• Height - 1 1/4” (31.8 mm)<br />

R-36 Exposed Fastener Panels<br />

• Width - 36” (914 mm)<br />

• Height - 1 1/4” (31.8 mm)<br />

7.2 Exposed Fastener Panels<br />

• Width - 36” (914 mm)<br />

• Height - 1 1/2” (38.1 mm)<br />

1/2” Corrugated Exposed Fastener Panels<br />

• Width - 40” (1016 mm)<br />

• Height - 1/2” (12.7 mm)<br />

7/8” Corrugated Exposed Fastener Panels<br />

• Width - 34.6” (879 mm)<br />

• Height - 7/8” (22.2 mm)<br />

Precision Wall Panels<br />

• Width – 12” or 16” (305, 406 mm)<br />

• Height – 7/8” (22 mm)<br />

40<br />

SPEC-DATA® is a registered trademark of Reed Elsevier Inc. The manufacturer is responsible for technical accuracy. ©2007 Reed Construction Data.<br />

All Rights Reserved.


FLASHING & TRIM<br />

All flashing and trim shall be fabricated by<br />

manufacturer or qualified fabricator. Flashing<br />

shall be PAC-CLAD aluminum (.032 - .063<br />

gauge as specified) or PAC-CLAD steel (24<br />

gauge G-90 galvanized or 22 gauge galvalume<br />

as specified). Vinyl masking is recommended<br />

on all fabrication applications<br />

where extra handling is expected. NOTE:<br />

The strippable film must be removed immediately<br />

after installation.<br />

COLORS<br />

Petersen Aluminum panels are available in<br />

the following PAC-CLAD finishes:<br />

• 24 gauge G-90 galvanized steel – 37<br />

stocked colors<br />

• 22 gauge galvalume steel – 13 stocked colors<br />

• .032 prime quality aluminum – 36<br />

stocked colors<br />

• .040 prime quality aluminum – 20<br />

stocked colors<br />

• .050 prime quality aluminum – 29<br />

stocked colors<br />

• 24 gauge Galvalume® Plus also available<br />

ACCESSORIES<br />

Petersen Aluminum fabricates a wide range<br />

of roofing accessories. Coping, gravel stops,<br />

gutters and downspouts are all formed from<br />

38 standard PAC-CLAD colors.<br />

LIMITATIONS<br />

Contact Petersen Aluminum regarding<br />

panel limitations as they pertain to your<br />

project specifics.<br />

4. Technical Data<br />

ASTM International<br />

• ASTM A653 Standard Specification for<br />

Steel Sheet, Zinc-Coated (Galvanized) or<br />

Zinc- Iron Alloy-Coated (Galvannealed) by<br />

the Hot-Dip Process<br />

• ASTM A792/A792M Standard Specification<br />

for Steel Sheet, 55 % Aluminum-Zinc<br />

Alloy- Coated by the Hot-Dip Process<br />

• ASTM B209 Standard Specification for Aluminum<br />

and Aluminum-Alloy Sheet and Plate<br />

• ASTM E283 Standard Test Method for<br />

Determining Rate of Air Leakage Through<br />

Exterior Windows, Curtain Walls, and<br />

Doors Under Specified Pressure Differences<br />

Across the Specimen<br />

• ASTM E331 Standard Test Method for<br />

Water Penetration of Exterior Windows,<br />

Skylights, Doors, and Curtain Walls by<br />

Uniform Static Air Pressure Difference<br />

• ASTM E1592 Standard Test Method for<br />

Structural Performance of Sheet <strong>Metal</strong><br />

Roof and Siding Systems by Uniform<br />

Static Air Pressure Difference<br />

• ASTM E1646 Standard Test Method for<br />

Water Penetration of Exterior <strong>Metal</strong> Roof<br />

Panel Systems by Uniform Static Air Pressure<br />

Difference<br />

• ASTM E1680 Standard Test Method for<br />

Rate of Air Leakage Through Exterior<br />

<strong>Metal</strong> Roof Panel Systems<br />

Underwriters Laboratories, Inc. (UL)<br />

• UL 263 Fire Tests of Building Construction<br />

and Materials<br />

• UL 580 Standard for Tests for Uplift Resistance<br />

of Roof Assemblies<br />

• UL 790 Standard Test Methods for Fire<br />

Tests of Roof Coverings<br />

• UL 1897 Uplift Tests for Roof Covering<br />

Systems<br />

• UL 2218 Standard for Impact Resistance<br />

of Prepared Roof Covering Materials<br />

ENVIRONMENTAL CONSIDERATIONS<br />

Where possible, Petersen Aluminum products<br />

include a high percentage of recycled<br />

material, which lowers the environmental<br />

footprint. Additionally, PAC products offer a<br />

long life span, and are 100% recyclable at<br />

the end of their extended service life, which<br />

may reduce the solid waste stream.<br />

Petersen also offers 29 finishes that are<br />

listed with the Cool Roof Ratings Council,<br />

31 finishes that are Energy Star approved,<br />

and 29 finishes that have an SRI of 29 or<br />

higher for steep slope roofs, for qualification<br />

towards credits for LEED’s Green Building<br />

Rating System.<br />

PHYSICAL PROPERTIES<br />

• TITE-LOC & TITE-LOC Plus – ASTM<br />

E331/1646 and ASTM E283/1680<br />

• SNAP-CLAD - ASTM E331/1646 and<br />

ASTM E283/1680<br />

• Snap On & High Snap-On - ASTM<br />

E331/1646 and ASTM E283/1680 (when<br />

applied over a solid substrate)<br />

• Redi-Roof & Redi-Roof Batten - ASTM<br />

E331/1646 and ASTM E283/1680 (when<br />

applied over a solid substrate)<br />

• Integral Panels - ASTM E331/1646 and<br />

ASTM E283/1680 (when applied over a<br />

solid substrate)<br />

• Flush Panels – ASTM E330<br />

• PAC 850 – ASTM E330<br />

• Precision Wall Series – ASTM E330,<br />

ASTM E283, ASTM E331, AAMA 501.1-05<br />

Test reports are available to design professionals<br />

upon request.<br />

5. Installation<br />

PREPARATORY WORK<br />

Handle and store products according to<br />

manufacturer’s recommendations.<br />

Deliver materials in manufacturer’s original,<br />

unopened, undamaged containers with<br />

identification labels intact. Store materials<br />

protected from exposure to harmful environmental<br />

conditions and at temperature<br />

and humidity conditions recommended by<br />

the manufacturer.<br />

Verify that site conditions are acceptable for<br />

installation. Do not proceed with installation<br />

until unacceptable conditions are corrected.<br />

METHODS<br />

Contact Petersen Aluminum for complete<br />

installation information.<br />

PRECAUTIONS<br />

In coastal applications, Petersen Aluminum<br />

recommends that stainless steel clips be<br />

used with prefinished aluminum in lieu of<br />

prefinished steel.<br />

BUILDING CODES<br />

Current data on building code requirements<br />

and product compliance can be obtained<br />

from Petersen Aluminum technical support<br />

specialists. Installation must comply with<br />

the requirements of all applicable local, state<br />

and national code jurisdictions.<br />

6. Availability & Cost<br />

AVAILABILITY<br />

Contact manufacturer for information on local<br />

availability.<br />

COST<br />

Budget installed cost information can be obtained<br />

from the manufacturer upon request.<br />

7. Warranty<br />

A full 20-year pro-rated finish warranty is<br />

available covering cracking, peeling and color<br />

fade on all PAC-CLAD applications. Finish<br />

warranty terms for Cardinal Red, Award Blue<br />

and Interstate Blue, and all metallic finishes,<br />

as well as embossed finishes, vary slightly.<br />

Please refer to www.pac-clad.com for further<br />

details.<br />

8. Maintenance<br />

Maintenance is not required. The panel finish<br />

is a member of the Teflon® family and is<br />

selfcleaning. If cleaning is desired, panels<br />

can be washed with mild soap and water followed<br />

by a clean water rinse.<br />

9. Technical Services<br />

Technical services are available from Petersen<br />

Aluminum Corp. and regional architectural<br />

representatives.<br />

10. Filing Systems<br />

• Reed First Source®<br />

• MANU-SPEC®<br />

• Additional product information is available<br />

from the manufacturer upon request.<br />

®<br />

SPEC-DATA<br />

SPEC-DATA® is a registered trademark of Reed Elsevier Inc. The manufacturer is responsible for technical accuracy. ©2007 Reed Construction Data.<br />

All Rights Reserved.<br />

41


PAC-CLAD Color Availability<br />

®<br />

SPEC-DATA<br />

PAC-CLAD Standard Reflectivity Emissivity 3 Year<br />

Exposure<br />

SRI*<br />

Steel<br />

24ga. 22ga.<br />

Aluminum<br />

.032 .040 .050 .063<br />

Almond 0.56 0.83 0.57 64 √ √ √ √ √ •<br />

Arcadia Green 0.33 0.84 0.32 33 √ √ •<br />

Bone White 0.71 0.85 0.71 86 √ √ √ √ √ √ •<br />

Cardinal Red 0.42 0.84 0.41 45 √ √ √ •<br />

Charcoal 0.28 0.84 0.28 27 √ √ √ •<br />

Cityscape 0.37 0.85 0.34 39 √ √ √ √ •<br />

Colonial Red 0.34 0.85 0.33 35 √ √ √ √ •<br />

Dark Bronze 0.27 0.85 0.26 26 √ √ √ √ √ √ •<br />

Evergreen 0.27 0.85 0.25 26 √ √ •<br />

Granite* 0.36 0.84 0.35 37 √ √ √ √ √ •<br />

Hemlock Green 0.30 0.85 0.31 30 √ √ √ √ •<br />

Hunter Green 0.26 0.84 0.26 24 √ √ •<br />

Mansard Brown 0.26 0.84 0.24 24 √ √ √ √ √ •<br />

Medium Bronze 0.30 0.85 0.29 30 √ √ √ √ √ √ •<br />

Military Blue 0.29 0.84 0.28 28 √ √ •<br />

Musket Gray 0.32 0.84 0.31 32 √ √ √ √ •<br />

Patina Green 0.34 0.85 0.33 35 √ √ •<br />

Sandstone 0.51 0.83 0.51 57 √ √ √ √ √ √ •<br />

Sierra Tan 0.38 0.85 0.35 40 √ √ √ √ √ •<br />

Slate Blue 0.25 0.84 0.27 23 √ √ •<br />

Slate Gray 0.38 0.84 0.37 40 √ √ √ √ √ •<br />

Stone White 0.61 0.86 0.59 72 √ √ √ √ √ √ •<br />

Teal 0.26 0.85 0.26 24 √ √ •<br />

Terra Cotta 0.37 0.84 0.37 39 √ √ √ •<br />

PAC-CLAD <strong>Metal</strong>lic<br />

Aged Copper 0.27 0.83 0.25 25 √ √ √ •<br />

Champagne 0.45 0.78 0.41 57 √ √ √ √ •<br />

Copper Penny 0.45 0.82 0.42 49 √ √ √ √ •<br />

Silver 0.53 0.80 0.51 59 √ √ √ √ •<br />

Weathered Zinc 0.27 0.80 0.27 23 √ √ √ •<br />

Zinc 0.30 0.85 0.30 30 √ √ √ √ •<br />

Galvalume Plus** 0.68 0.14 0.55 57 √<br />

Energy<br />

Star®<br />

PAC-CLAD Standard Colors (do not meet cool roof requirements)<br />

Award Blue √ √ √<br />

Berkshire Blue* 0.25 0.84 0.22 23 √ •<br />

Burgundy √ √ √<br />

Forest Green √ √ √ √ √<br />

Hartford Green √ √ √ √<br />

Interstate Blue √ √ √<br />

Matte Black √ √ √ √ √<br />

Midnight Bronze<br />

√<br />

PAC-CLAD® <strong>Metal</strong>lic finishes are available from stock at a moderate extra cost. PAC-CLAD® Copper Penny is a Non-Weathering finish.<br />

Solar Reflectance Index calculated according to ASTM C-1549. *Low Gloss/Low Sheen,full Kynar 500® or Hylar 5000® finish **Acrylic coated, non-Kynar Finish.<br />

42<br />

SPEC-DATA® is a registered trademark of Reed Elsevier Inc. The manufacturer is responsible for technical accuracy. ©2007 Reed Construction Data.<br />

All Rights Reserved.


Notes:<br />

PETERSEN ALUMINUM CORPORATION<br />

www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935<br />

43


www.pac-clad.com / email: sales@petersenmail.com<br />

HQ: 1005 Tonne Road<br />

Elk Grove Village, IL 60007<br />

P: 800-PAC-CLAD<br />

F: 800-722-7150<br />

9060 Junction Drive<br />

Annapolis Junction, MD 20701<br />

P: 800-344-1400<br />

F: 301-953-7627<br />

10551 PAC Road<br />

Tyler, TX 75707<br />

P: 800-441-8661<br />

F: 903-581-8592<br />

102 Northpoint Pkwy<br />

Acworth, GA 30102<br />

P: 800-272-4482<br />

F: 770-420-2533<br />

350 73rd Ave., NE Suite 1<br />

Fridley, MN 55432<br />

P: 877-571-2025<br />

F: 866-901-2935