SNAP-CLAD<br />
Technical Information and<br />
Flashing Details<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
Product Information:<br />
PAGE 3<br />
SNAP-CLAD Spec. Sheet<br />
PAGES 4-13<br />
UL List Cards - UL Construction Numbers<br />
261, 254, 255, 263, 343, 303, 508, 508A, 614, 790<br />
PAGE 14<br />
UL Construction Code<br />
Miami-Dade/Florida Product Approvals<br />
PAGES 15-38<br />
SNAP-CLAD Flashing Details<br />
PAGES 39-42<br />
SPEC-DATA® Sheet<br />
PAC, Petersen Aluminum Corporation reserves the right to discontinue products at any time or change<br />
specification and/or designs without notice and without incurring obligation. Application details are<br />
for illustration purposes only, and may not be appropriate for all environmental conditions, building<br />
designs, or panel profiles. Projects should be engineered to conform to applicable building codes,<br />
regulations, and accepted industry practices. Descriptions and specifications contained herein were in<br />
effect at the time this publication was approved for printing. Petersen Aluminum Corporation does not<br />
build or design buildings. It acts solely as a supplier of materials, and assumes no responsibility for the<br />
proper use or installation of those materials, nor for the suitability of those materials for any specific use<br />
or for compliance with local building codes.<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
2<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
SNAP-CLAD<br />
sealant bead (optional)<br />
1-3/4"<br />
10", 12", 16" or 18" O.C.<br />
SNAP-CLAD <br />
10”, 12”, 16” or 18” O.C. .032 aluminum<br />
1-3/4” high .040 aluminum<br />
24 gauge steel<br />
22 gauge steel<br />
16 oz. copper<br />
U.L. Construction Numbers 261, 254, 255, 343, 303, 508, 508A, 614<br />
SNAP-CLAD Panels feature architectural panel aesthetics as well as structural panel performance.<br />
These panels carry a U.L. rating over a wide variety of assemblies as indicated by the above listed U.L.<br />
Construction numbers.<br />
Features:<br />
Requirements:<br />
.032 aluminum, .040 aluminum, 24 ga. steel, or 22 ga. steel, 16 oz. copper<br />
(Standard Colors are limited in 22 ga. steel & .040 aluminum)<br />
10” o.c., 12” o.c., 16” o.c., 18” o.c.<br />
Factory Applied Sealant Bead in Seam (Optional)<br />
Tension Leveled<br />
Available Smooth, with Stiffening Beads or with Striations<br />
Factory Eave Notching<br />
Solid Substrate, Open Framing, or Rigid Insulation<br />
Vapor Barrier (on solid substrate and rigid insulation)<br />
Clips (U.L. 90 Clip or Standard Clip)<br />
Bearing Plates: Required when used in assembly including rigid insulation over<br />
metal decking.<br />
Minimum Roof Pitch: 2” on 12”<br />
(If less than 2” on 12”, contact our factory.)<br />
SNAP-CLAD<br />
Finish:<br />
Air & Water Infiltration Tested:<br />
PAC-CLAD® (Kynar 500® or Hylar 5000®)<br />
ASTM E283/1680 and E331/1646<br />
Miami-Dade NOA & Florida<br />
Approvals:<br />
Note:<br />
Petersen Aluminum’s Snap-<strong>Clad</strong> Panel is thoroughly tested to meet the<br />
requirements of Miami-Dade and the Florida Building codes. Please refer to<br />
our website, www.pac-clad.com, for specific NOA & Florida Building Approvals<br />
available by gauge and building assembly.<br />
When a U.L. Rating is required, Petersen Aluminum Corporation must be<br />
notified prior to fabrication of the panels.<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
3
UL Construction No. 254<br />
Wind-Uplift - Class 90 (See Item No. 4) / Fire Not Investigated<br />
UL Construction No. 254<br />
1<br />
2<br />
3<br />
4<br />
<strong>Metal</strong> Roof Deck Panels*<br />
“Snap-<strong>Clad</strong>”<br />
Roof Deck Fasteners* (Panel Clips)<br />
“Snap-<strong>Clad</strong> Clip”<br />
Panel Fasteners (Screws)<br />
Purlins<br />
No. 22 MSG or No. 24 MSG min. thickness coated steel panels. Panels<br />
12 in. wide max., 10 in. wide min. 1-3/4 in. high at the ribs. Panels<br />
continuous over two or more spans. A bead of sealant may be used at<br />
panel side joints.<br />
One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. One panel clip<br />
located at each purlin intersection.<br />
Fasteners used to attach panel clips (item 2) to purlins to be No. 10-16<br />
by 1 in. long No. 3 self-drilling point, No. 2 Phillips drive head, cadmium<br />
plated steel screws. Two screws per clip to be used, inserted through<br />
1/4 in. diameter guide holes.<br />
No. 16 MSG min. thickness steel (50,000 psi min. yield strength).<br />
Spacing:<br />
For 22 MSG thickness panels - 60 in. OC<br />
For 24 MSG thickness panels - 48 in. OC<br />
*Bearing the UL Classification Marking<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
4<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
UL Construction No. 255<br />
Wind-Uplift - Class 90 and 60 (See Item No. 4) / Fire Not Investigated<br />
1<br />
2<br />
3<br />
4<br />
<strong>Metal</strong> Roof Deck Panels*<br />
“Snap-<strong>Clad</strong>”<br />
Roof Deck Fasteners* (Panel Clips)<br />
“Snap-<strong>Clad</strong> Clip”<br />
Panel Fasteners (Screws)<br />
Purlins<br />
No. 24 MSG min. thickness coated steel. Panels 18 in. wide max., 10 in.<br />
wide min. 1-3/4 in. high at the ribs. Panels continuous over two or more<br />
spans. A bead of sealant may be used at panel side joints.<br />
One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. One panel clip<br />
located at each purlin intersection.<br />
Fasteners used to attach panel clips (item 2) to purlins to be No. 10-16<br />
by 1 in. long cadmium plated pancake head No. 2 phillips drive, No. 3<br />
self-drilling point steel screws. Two screws per clip to be used inserted<br />
through 1/4 in. diameter guide holes.<br />
No. 16 MSG min. thickness steel (50,000 psi min. yield strength).<br />
Spacing for Class 90 to be 48 in. OC: For Class 60 to be 60 in. OC<br />
UL Construction No. 255<br />
*Bearing the UL Classification Marking<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
5
UL Construction No. 261<br />
Wind-Uplift - Class 90 or 60 (See Item No. 4) / Fire Not Investigated<br />
UL Construction No. 261<br />
1<br />
2<br />
3<br />
4<br />
<strong>Metal</strong> Roof Deck Panels*<br />
“Snap-<strong>Clad</strong>”<br />
Roof Deck Fasteners* (Panel Clips)<br />
“Snap-<strong>Clad</strong> Clip”<br />
Panel Fasteners (Screws)<br />
Purlins<br />
0.032 in. thick aluminum or No. 24 MSG min. thickness coated steel.<br />
Panels 10 in. wide. 1-3/4 in. high at the ribs. Panels continuous over two<br />
or more spans. A bead of sealant may be used at panel side joints.<br />
One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. One panel clip<br />
located at each purlin intersection.<br />
Fasteners used to attach panel clips (Item 2) to purlins to be No. 10-16<br />
by 1 in. long cadmium plated, pancake head, No. 2 phillips drive, No. 3<br />
self-drilling point. Two screws per clip to be used, inserted through 1/4<br />
in. diameter guide holes in clip base.<br />
No. 16 MSG min. thickness steel (50,000 psi min. yield strength).<br />
Spacing for aluminum panels:<br />
For Class 90 to be 36 in. OC.<br />
For Class 60 to be 48 in. OC.<br />
Spacing for steel panels:<br />
22 MSG thick to be 60 in. OC.<br />
24 MSG thick to be 48 in. OC.<br />
*Bearing the UL Classification Marking<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
6<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
UL Construction No. 303<br />
Uplift - Class 90 / Fire Not Investigated<br />
1<br />
<strong>Metal</strong> Roof Deck Panels * / “Snap-<strong>Clad</strong>”<br />
No. 24 MSG min thickness coated steel. Panel width 18 in. max.,<br />
10 in. min., 1-3/4 in. high at the ribs. A bead of sealant may be<br />
used at panel side joints.<br />
2<br />
3<br />
4<br />
5<br />
6<br />
A<br />
<strong>Metal</strong> Roof Deck Panels* (Not Shown)<br />
0.032 in. min thick aluminum, 16 in. wide max, 10 in.<br />
wide min, 1-3/4 in. high at the rib. A bead of sealant may<br />
be used at panel side joints.<br />
Roof Deck Fasteners* (Panel Clips) / “Snap-<strong>Clad</strong> Clip”<br />
One piece assembly, 3-1/2 in. wide, 1-7/8 in.. high. Clip spacing<br />
to be 48 in. max. OC for steel panels and 18 in. max. OC for<br />
aluminum panels. Clips to interface with Item 2A (bearing plate).<br />
A<br />
Bearing Plate* (Not Shown)<br />
To be used with “Snap-<strong>Clad</strong> Clips” only (Item 2). To be<br />
24 MSG thick coated steel, nom 4-5/8 in. wide by<br />
6 in. long.<br />
Panel Fasteners (Screws)<br />
Fasteners used to attach panel clips and bearing plates (Items 2 &<br />
2A) through rigid insulation and optional OSB and/or gypsum board<br />
and into light gauge steel deck (Item No. 5) to be No. 14 truss head<br />
type with No. 3 Phillips drive, self-drilling steel screws. Two screws<br />
per clip to be used, inserted through 1/4 in. diameter guide holes.<br />
Fasteners to penetrate liner panel 3/4 in. min.<br />
Foamed Plastic (Rigid Insulation)<br />
Min thickness 1 in., max thickness 4-1/2 in. Density to be a min of<br />
1.8 pcf.<br />
A<br />
B<br />
Oriented Strand Board (OSB) (Optional) (Not Shown)<br />
Located over foamed plastic (Item 4). Max thickness 7/16<br />
in. Note: Bearing plates not required when OSB is used.<br />
Gypsum Board (Optional)<br />
Max thickness 5/8 in. Located over liner panel (Item 5).<br />
Liner Panel<br />
Min thickness No. 22 MSG. Coated steel (33,000 psi) min yield<br />
strength min. depth 1-1/2 in., max. pitch 6 in., fabricated to various<br />
profiles.<br />
Underlayment (Not shown)<br />
One ply of 30 lb roofing felt or one layer of bituminous resin type<br />
water proofing membrane.<br />
UL Construction No. 303<br />
7<br />
Supports (Not Shown)<br />
Used to support liner panels, spaced per deck manufacturer’s<br />
specifications for uplift.<br />
*Bearing the UL Classification Marking<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
7
UL Construction No. 343<br />
Uplift - Class 90 / Fire Not Investigated<br />
UL Construction No. 343<br />
1<br />
2<br />
3<br />
4<br />
5<br />
<strong>Metal</strong> Roof Deck Panels* / “Snap-<strong>Clad</strong>”<br />
No. 24 MSG min. coated steel panels 18 in. wide max., 10 in.<br />
wide min., 1-3/4 in. high at the ribs. A bead of sealant may be<br />
used at panel side joints.<br />
Roof Deck Fasteners* (Panel Clips) / “Snap-<strong>Clad</strong> Clip”<br />
One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. Clips spaced<br />
36 in. OC, max, fastened to plywood deck.<br />
Panel Fasteners (Screws)<br />
Fasteners used to attach panel clips (Item 2) to plywood to<br />
be No. 10-12 by 1 in. long pancake head, No. 2 Phillips drive,<br />
A-point, coated steel screw. Min two fasteners per clip to used.<br />
Underlayment<br />
Underlayment used over plywood deck to be Type 15 or<br />
30 organic felt. Sides overlapped min. 2 in., end laps per<br />
manufacturer’s instructions. Felt nailed to plywood deck with<br />
1-1/4 in. long steel cap nails, located per manufacturer’s<br />
instructions. Nail spacing to be max 12 in. OC at the side lap<br />
and max 24 in. OC in interior rows.<br />
As An Alternate: A self-adhering modified bitumen water<br />
proofing membrane may be used, installed per manufacturer’s<br />
instructions. Note: when alternate is used the plywood joints<br />
need not be sealed.<br />
Plywood Decking<br />
Plywood decking to be graded per PS83 specifications, 19/32<br />
in. thick, exposure 1, APA Rated Sheathing (42/20) square<br />
edged, Butt ends not blocked. All butt and side joints to be<br />
sealed with a one part urethane caulk sealant applied with<br />
a caulking gun and feathered outward from the joint. (Note<br />
exception under Item No. 4, alternate.)<br />
6<br />
7<br />
Supports (Not Shown)<br />
Spaced max of 24 in. OC. Any of the following types may be<br />
used to support the plywood decking:<br />
a) Nom. 2 by 6 in., No. 2 grade or better S-P-F, Hemlock Fir,<br />
Douglas Fir or Southern Yellow Pine or equivalent.<br />
b) Wood trusses with a nom. 2 by 4 in. upper chord of the<br />
same grade as item a.<br />
c) No. 22 MSG min cold formed coated steel (min. yield to be<br />
33,000 psi).<br />
Plywood Fasteners (Not Shown)<br />
Fasteners used to attach the plywood deck or OSB to the<br />
supports to be as follows:<br />
a) For plywood-to-wood supports No. 8-18 by 1-7/8 in. long<br />
bugle-head steel screws with a No. 2 Phillips drive, a<br />
“Hi-Low” thread pattern and an “S-Point”.<br />
b) As an alternate to Item a, 8d common nails may be used.<br />
c) For plywood-to-steel supports for a steel thickness less<br />
than No. 20 MSG No. 7-19 by 1-1/4 in. long bugle-head steel<br />
screws with a No. 2 Phillips head drive “Hi-Low” threads and an<br />
“S-Point”. For a steel thickness greater than No. 20 MSG to No.<br />
16 MSG, No. 6-20 by 1-1/4 in. long bugle-head steel screws<br />
with a No. 2 Phillips drive and a S12 (TEKS/3)supR point.<br />
Spacing: Fastener spacing for all fastener types to be 6 in. OC<br />
at the plywood edges and 12 in. OC in the interior.<br />
Refer to General Information, Roof Deck Construction (Building<br />
Materials Directory) for items not evaluated.<br />
*Bearing the UL Classification Marking<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
8<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
1.75” NOM.<br />
UL Construction No. 508<br />
Uplift - Class 90 / Fire Not Investigated<br />
16” MAX<br />
1.75” NOM.<br />
1<br />
2<br />
3<br />
1.75” NOM.<br />
4<br />
5<br />
24” MAX<br />
<strong>Metal</strong> Roof Deck Panels* / “Snap-<strong>Clad</strong>”<br />
0.032 in. min. thick aluminum; Panels 16 in. wide max., 10 in.<br />
wide min., 1-3/4 in. high at the rib. A bead of sealant may be<br />
used at panel side joints.<br />
Roof Deck Fasteners* (Panel Clips) / “Snap-<strong>Clad</strong> Clip”<br />
One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. Clips<br />
spaced 18 in. OC.<br />
Panel Fasteners (Screws)<br />
Fasteners used to attach panel clips (Item 2) to plywood (Item<br />
5) to be No. 10-12 by 1 in. long, No. 1 Phillips drive, bugle head<br />
coated steel wood screws. Two screws used per clip inserted<br />
through 1/4 in. diameter guide holes.<br />
Underlayment<br />
Underlayment used over plywood deck to be Type 30 organic<br />
felt. Sides overlapped min. 2 in., end laps per manufacturer’s<br />
instructions. Felt nailed to plywood deck with 1 in. long<br />
galvanized steel roofing nails, located per manufacturer’s<br />
18” Max. (Steel)<br />
instructions. Nail spacing to be max 12 in. OC at the side lap<br />
16” Max. (Alum.)<br />
and max 24 in. OC in interior rows.<br />
As An Alternate: A self-adhering modified bitumen water<br />
proofing membrane may be used, installed per manufacturer’s<br />
instructions. Note: when alternate is used the plywood joints<br />
need not be sealed.<br />
Plywood Decking<br />
Plywood decking to be graded per PS83 specifications, 19/32<br />
in. thick, exposure 1, APA rated sheathing (42/20) square<br />
edged, Butt ends not blocked.<br />
6<br />
7<br />
Supports<br />
Spaced max 24 in. OC. Any of the following types may be used<br />
to support the plywood decking:<br />
a) 2 by 6 in., min No. 2 grade A.F.P.A. S-P-F Hemlock Fir,<br />
Douglas Fir or Southern Pine or equivalent.<br />
b) Wood trusses with a nominal 2 by 4 in. upper chord of the<br />
same grade as item a.<br />
c) No. 22 MSG min thick cold formed coated steel (min. yield to<br />
be 33,000 psi).<br />
Plywood Fasteners<br />
(Not shown) Fasteners used to attach the plywood deck to the<br />
supports to be as follows:<br />
a) For plywood-to-wood supports No. 8-18 by 1-7/8 in. long<br />
bugle-head steel screws with a No. 2 Phillips drive, a “Hi-Low”<br />
thread pattern and an “S-Point”.<br />
b) As an alternate to Item a, 8d by 2-1/2 in. long deformed<br />
shank common nails may be used.<br />
c) For plywood-to-steel supports for a steel thickness less<br />
than No. 20 MSG, No. 7-19 by 1-1/4 in. long bugle-head steel<br />
screws with a No. 2 Phillips head drive “Hi-Low” threads and<br />
an “S-Point”. For a steel thickness greater than No. 20 MSG<br />
to No. 16 MSG, No. 6-20 by 1-1/4 in. long bugle-head steel<br />
screws with a No. 2 Phillips drive and a S12 (TEKS/3)® point.<br />
Spacing: Fastener spacing for all fastener types to be 6 in. OC<br />
at the plywood edges and 12 in. OC in the interior.<br />
Refer to General Information, Roof Deck Construction (<strong>Roofing</strong><br />
Materials and Systems Directory) for items not evaluated.<br />
*Bearing the UL Classification Marking<br />
UL Construction No. 508<br />
1.75” NOM.<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
9
UL Construction No. 508A<br />
Uplift - Class 90 / Fire Not Investigated<br />
18" MAX. (STEEL)<br />
16" MAX. (ALUM.)<br />
UL Construction No. 508A<br />
1<br />
2<br />
3<br />
4<br />
5<br />
<strong>Metal</strong> Roof Deck Panels* / “Snap-<strong>Clad</strong>”<br />
No. 24 MSG min. thick coated steel panels, 18 in. wide max.,<br />
10 in. wide min., or 0.032 in. min. thick aluminum, 16 in. wide<br />
max., 10 in. wide min., 1 3/4 in. high at the rib. A bead of<br />
sealant may be used at panel side joints.<br />
Roof Deck Fasteners* (Panel Clips) / “Snap-<strong>Clad</strong> Clip”<br />
One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. Clips<br />
spaced 36 in. OC max for steel panels and 18 in. OC max for<br />
aluminum panels. Fastened to nailable insulation (Item 5).<br />
Fasteners (Screws)<br />
Fasteners used to attach panel clip (Item 2) to nailable<br />
insulation (Item 5) to be No. 10-12 by 1 in. long pancake head,<br />
No. 2 Phillips drive, A-point coated steel screws. Min. two<br />
fasteners per clip.<br />
Underlayment<br />
Underlayment used over nailable insulation (Item 5) to be<br />
Type 30 organic felt. Sides overlapped min. 2 in. End laps per<br />
manufacturer’s instructions. Felt nailed to nailable insulation<br />
with 1 in. long galvanized steel roofing nails, located in side<br />
laps and between side lap per manufacturer’s instructions. Nail<br />
spacing to be max 12 in. OC at the side lap and max 24 in. OC<br />
in interior rows.<br />
Nailable Insulation<br />
Consisting of 1 in. min. to 3-1/2 in. max thick Classified<br />
polyisocyanurate foamed plastic with a factory laminated 7/16<br />
in. thick APA rated O.S.B. Density of foamed plastic to be 2 pcf.<br />
5<br />
7<br />
8<br />
7<br />
8<br />
9<br />
2<br />
1<br />
3<br />
4<br />
5<br />
1.750 NOM.<br />
Fasteners (Screws)<br />
Fasteners used to attach nailable insulation (Item 5) to liner<br />
panel (Item 8) to be No. 11-13, No. 3 Phillips drive, truss head,<br />
painted steel screws. Length to depend on overall thickness of<br />
deck and to penetrate steel deck 1/2 in. min. A 2 in. diameter<br />
formed pressure plate fabricated from No. 22 MSG coated steel<br />
to be used with each screw. Fasteners located in three rows<br />
along the 8 ft. length of the nailable insulation beginning 6 in.<br />
from the 8 ft. edges with a row down the center and spaced<br />
21 in. OC beginning 6 in. from the 4 ft. edges. A total of 15<br />
fasteners used for each 4 by 8 ft. board.<br />
Liner Panel (Steel Deck)<br />
No. 22 MSG min. thick coated steel. Min. depth 1-1/2 in., max<br />
pitch 6 in. fabricated to various profiles. Min. yield strength<br />
33,000 psi. Fastened to supports (Item 6) with fastener type and<br />
spacing per liner panel manufacturer’s instructions for<br />
uplift loading.<br />
Gypsum Board (Optional - Not Shown)<br />
Max. thick 5/8 in. supplied in 4 by 8 ft. sheets. Butt joints<br />
located over crests of metal roof deck panel (Item 1). Fastened<br />
to panel with same fasteners used for nailable insulation<br />
(Item 5).<br />
Refer to General Information, Roof Deck Construction (<strong>Roofing</strong><br />
Materials and Systems Directory) for items not evaluated.<br />
6<br />
Supports (Purlins)<br />
Purlins used for liner panel (Item 8) support to be cold formed<br />
steel sections. As alternatives, structural steel components (hot<br />
rolled beams, channels, open web joists, etc.) may be used.<br />
Min. gauge and yield to depend on design considerations for<br />
uplift loading with max spacing to be 6 ft. OC.<br />
*Bearing the UL Classification Marking<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
10<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
1.75” NOM.<br />
UL Construction No. 614<br />
Uplift - Class 90 / Fire Not Investigated<br />
16” MAX<br />
1.75” NOM.<br />
1<br />
2<br />
3<br />
1.75” NOM.<br />
4<br />
5<br />
6<br />
<strong>Metal</strong> Roof Deck Panels* / “Snap-<strong>Clad</strong>”<br />
16 in. wide max., 10 in. wide min., 1-3/4 in. high at the rib,<br />
fabricated from 16 oz., half-hard copper. A bead of sealant<br />
may be used at panel side joints.<br />
Roof Deck Fasteners* (Panel Clips) / “Snap-<strong>Clad</strong> Clip”<br />
One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. The clips are<br />
to be spaced a maximum of 24 in. OC.<br />
Panel Fasteners (Screws)<br />
Fasteners used to attach panel clips (Item 2) to plywood (Item<br />
5) to be No. 10-16 by 1 in. long, No. 1 in. pancake head coated<br />
stainless steel screws. Two screws used per clip inserted<br />
through 1/4 in. diameter guide holes.<br />
Underlayment*<br />
Any UL Classified base or ply sheet, mechanically fastened with<br />
nails or staples.<br />
A Underlayment: Rosin paper, 9 mil. thick, mechanically<br />
18” Max. (Steel)<br />
fastened with nails or staples.<br />
16” Max. (Alum.)<br />
24” MAX<br />
Plywood Decking<br />
Plywood decking to be graded per PS83 specification, 19/32<br />
in. thick, Grade B-C, exposure 1, APA rated sheathing (42/20)<br />
square edged. All plywood joints to be sealed against leakage<br />
with caulk or a one part urethane sealant.<br />
Supports<br />
Spaced max 24 in. OC. Any of the following types may be used<br />
to support the plywood decking:<br />
a) 2 by 6 in., min. No. 2 grade A.F.P.A. S-P-F Hemlock Fir,<br />
Douglas Fir or Southern Pine or equivalent.<br />
b) Wood trusses with a nominal 2 by 4 in. upper chord of the<br />
same grade as item a.<br />
7<br />
c) No. 22 MSG min. thick cold formed coated steel (min. yield<br />
to be 33,000 psi).<br />
Plywood Fasteners (Not shown)<br />
Fasteners used to attach the plywood deck (Item 5) to the<br />
supports (Item 6) to be as follows:<br />
a) For plywood-to-wood supports, No. 8-18 by 1-7/8 in. long<br />
bugle-head steel screws with a No. 2 Phillips drive, a “Hi-Low”<br />
thread pattern and an “S-Point”.<br />
b) As an alternate to Item a, 8d by 2-1/2 in. long deformed<br />
shank common nails may be used.<br />
c) For plywood-to-steel supports for a steel thickness less<br />
than No. 20 MSG, No. 7-19 by 1-1/4 in. long bugle-head steel<br />
screws with a No. 2 Phillips head drive “Hi-Low” thread and an<br />
“S-Point.” For a steel thickness greater than No. 20 MSG to No.<br />
16 MSG, No. 6-20 by 1-1/4 in. long bugle-head steel screws<br />
with a No. 2 Phillips drive and a S12 (TEKS/3)® point.<br />
Spacing: Fastener spacing for all fastener types to be 6 in. OC<br />
at the plywood edges and 12 in. OC in the interior.<br />
Refer to General Information, Roof Deck Construction (<strong>Roofing</strong><br />
Materials and Systems Directory) for items not evaluated.<br />
*Bearing the UL Classification Marking<br />
UL Construction No. 614<br />
1.75” NOM.<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
11
UL Construction No. 790<br />
Class A<br />
Coated Steel and aluminum panels identified as Snap-On Standing Seam, High Snap-On Standing Seam,<br />
Snap-On Batten, Integral Batten, Redi-Roof Batten, Redi-Roof Standing Seam, Snap-<strong>Clad</strong>, Integral<br />
Standing Seam, Tite-Loc and Tite-Loc Plus.<br />
UL Construction No. 790<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
Deck:<br />
Incline:<br />
Barrier Board:<br />
Ply Sheet (optional):<br />
Surfacing:<br />
Deck:<br />
Incline:<br />
Barrier Board:<br />
Ply Sheet (optional):<br />
Surfacing:<br />
Deck:<br />
Incline:<br />
Barrier Board:<br />
Ply Sheet (optional):<br />
Surfacing:<br />
Deck:<br />
Incline:<br />
Barrier Board:<br />
Ply Sheet (optional):<br />
Surfacing:<br />
Deck:<br />
Incline:<br />
Surfacing:<br />
Deck:<br />
Incline:<br />
Barrier Board:<br />
Ply Sheet (optional):<br />
Surfacing:<br />
NC<br />
No Limitations<br />
1/4 in. min. Georgia <strong>Pac</strong>ific Corp. Dens-Deck Overlayment Board<br />
Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified<br />
prepared roofing accessory or WR Grace “Ice and Water Shield”<br />
Steel or aluminum roofing panels, mechanically fastened<br />
NC<br />
No Limitations<br />
5/8 in min. plywood<br />
Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified<br />
prepared roofing accessory or WR Grace “Ice and Water Shield”<br />
Steel roofing panels mechanically fastened<br />
NC<br />
No Limitations<br />
7/16 OSB or 5/8 in. plywood over polyisocyanurate insulation board or polyisocyanurate<br />
composite board, any thickness<br />
Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified<br />
prepared roofing accessory or WR Grace “Ice and Water Shield”<br />
Steel or aluminum roofing panels mechanically fastened<br />
NC<br />
No Limitations<br />
Polyisocyanurate, glass fiber, perlite or wood fiber, any thickness<br />
Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified<br />
prepared roofing accessory or WR Grace “Ice and Water Shield”<br />
Steel or aluminum roofing panels mechanically fastened<br />
NC<br />
No Limitations<br />
Steel roofing panels mechanically attached to metal purlins<br />
C-15/32<br />
No Limitations<br />
Georgia <strong>Pac</strong>ific Corp. 1/4 in. (min.) Dens-Deck with all joints staggered a min. of 6 in. from the<br />
plywood joints<br />
Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified<br />
prepared roofing accessory or WR Grace “Ice and Water Shield”<br />
Steel or aluminum roofing panels mechanically fastened<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
12<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
UL Construction No. 263<br />
<strong>Metal</strong> Roof Deck Panels / File R14293<br />
Mechanically Attached <strong>Metal</strong> Roof Panels<br />
1<br />
2<br />
3<br />
Mechanically Attached<br />
<strong>Metal</strong> Roof Panels<br />
For use in Design Numbers:<br />
Mechanically Attached<br />
<strong>Metal</strong> Roof Panels<br />
For use in Design Numbers:<br />
Mechanically Attached <strong>Metal</strong><br />
Roof Panels<br />
For use in Design Numbers:<br />
Type “Snap-<strong>Clad</strong>” roof deck panels (No. 24 MSG min gauge coated steel or 0.032<br />
min. gauge coated aluminum) placed over specified insulation and/or roof covering<br />
for respective designs. Type “Snap-<strong>Clad</strong>” panels are secured by “Snap-<strong>Clad</strong> Clips”<br />
with the upper portion of the clip engaging the panel rib. A 4-1/2 by 6 in. bearing<br />
plate fabricated from No. 26 MSG coated steel is used under each panel clip (the<br />
bearing plate shall be placed over the specified insulation). Panel clips are attached<br />
to the steel deck with No. 14 steel screws having a No. 3 Phillips-drive truss head<br />
with an off-set drill-type point. Two fasteners per clip are used.<br />
P225, P227, P230, P233, P237, P259, P508, P510, P512, P514, P701, P711, P717,<br />
P720, P722, P723, P724, P726, P731, P734, P736, P801, P815, P819 and P821.<br />
Types “High Snap-On Standing Seam”, “Snap-On Standing Seam”, “Integral<br />
Batten”, “Integral Standing Seam”, “Redi-Roof Standing Seam”, “Redi-Roof Batten”,<br />
“Snap-<strong>Clad</strong>”, “Tite-Loc”, “Tite-Loc Plus” roof deck panels (No. 24 MSG min. gauge<br />
coated steel or 0.032 min. gauge coated aluminum) placed over specified insulation<br />
and/or roof covering for respective designs. Panels secured to a top layer of<br />
7/16 in. APA-Rated oriented stand board (OSB) laminated to rigid insulation or 5/8<br />
in. plywood over rigid insulation. Panels secured to oriented strand board or plywood<br />
at side ribs with panel clips designed specifically for these panels. Panel clips<br />
spaced 18 in. OC using No. 10 by 1-1/4 in. long self-drilling, self tapping wafer head.<br />
Zinc-plated carbon steel screws. The oriented strand board laminated insulation or<br />
plywood covered rigid insulation are mechanically fastened to steel roof deck and<br />
covered with a 30 lb. felt.<br />
P225, P227, P230, P233, P237, P259, P263, P508, P510, P512, P514, P515, P701,<br />
P711, P717, P720, P722, P723, P724, P726, P731, P734, P736, P801, P815, P819<br />
and P821.<br />
Types “Tite-Loc” and “Tite-Loc Plus” roof deck panels (No. 24 MSG min. gauge<br />
coated steel or 0.032 min. gauge coated aluminum) placed over specified insulation<br />
and/or roof covering for respective designs. Both types secured to hat sections+ or<br />
bearing plates++ with panel clips designed for the particular panel.<br />
P225, P227, P230, P233, P237, P508, P510, P512, P701, P711, P715, P717, P720,<br />
P722, P724, P726, P731, P734, P736, P801, P815, P819, P821<br />
+Hat-shaped member to be a minimum of 16 MSG, 1 in. min. depth. Member to be fastened through<br />
the roof insulation to the steel roof deck with No. 14 self-drilling and/or self-tapping fasteners. Spacing<br />
to be determined by the structural loading requirements. In addition, any compressible UL Classified<br />
glass fiber compressible blanket insulation with or without a vapor retarding facing may be used<br />
between the specified roof insulation and the metal roof panels.<br />
UL Construction No. 263<br />
++Bearing plate to be a minimum of 16 MSG. Member to be fastened through the roof insulation to<br />
the steel deck with No. 14 self-drilling and/or self-tapping fasteners.<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
13
UL Construction Code<br />
Maximum Clip Spacing<br />
Substrates<br />
Rigid Insulation Over<br />
UL Construction Code<br />
Gauge<br />
22 GA<br />
24 GA<br />
0.032<br />
0.040<br />
16 Oz. Copper<br />
1<br />
2<br />
3<br />
10”<br />
Width<br />
18”, 16”, 12”, 10”<br />
18”, 16”, 12”, 10”<br />
10”<br />
12”, 10”<br />
18”, 16”, 12”, 10”<br />
18”, 16”, 12”, 10”<br />
10”<br />
16”, 12”, 10”<br />
16”, 12”, 10”<br />
10”<br />
16”, 12”, 10”<br />
16”, 12”, 10”<br />
16”, 12”, 10”<br />
Open Frame Purlins<br />
UL 261 (5’-0”)<br />
UL 255 (4’-0”)<br />
UL 261 (4’-0”)<br />
UL 254 (4’-0”)<br />
UL 255 (4’-0”)<br />
UL 261 (3’-0”)<br />
UL 261 (3’-0”)<br />
5/8” Plywood<br />
UL 343 (3’-0”)<br />
UL 343 (3’-0”)<br />
UL 508 (1’-6”)<br />
UL 508 (1’-6”)<br />
UL 614 (2’-0”)<br />
Contact Petersen Aluminum Corporation for complete UL construction assemblies.<br />
22 GA Steel Deck<br />
With Bearing Plates<br />
UL 508A (3’-0”)<br />
UL 303 (4’-0”)<br />
UL 303 (4’-0”)<br />
UL 508A (3’-0”)<br />
UL 303 (1’-6”)<br />
UL 508A (1’-6”)<br />
UL 303 (1’-6”)<br />
UL 508A (1’-6”)<br />
For complete information regarding appropriate purlin spacing, contact Petersen Aluminum Corporation directly.<br />
Insulation thicknesses varies between 1” and 4-1/2” according to R-value desired. Refer to UL <strong>Roofing</strong> Materials directly.<br />
SNAP-CLAD MIAMI-DADE NOA’S & FLORIDA APPROVALS<br />
Petersen Aluminum’s Snap <strong>Clad</strong> panel is thoroughly tested to meet the requirements of Miami-Dade and<br />
Florida Building codes. Please refer to our website, www.pac-clad.com, for specific NOA’s and Florida<br />
Building Approvals available by gauge and building assembly.<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
14<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
Hip/Ridge Detail<br />
Job Name:<br />
SNAP-CLAD Flashing Details<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
15
Eave Detail<br />
SNAP-CLAD Flashing Details<br />
Job Name:<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
16<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
Eave Detail<br />
Job Name:<br />
SNAP-CLAD Flashing Details<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
17
Eave Detail<br />
SNAP-CLAD Flashing Details<br />
Job Name:<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
18<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
Valley Detail<br />
Job Name:<br />
SNAP-CLAD Flashing Details<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
19
Peak Detail<br />
SNAP-CLAD Flashing Details<br />
Job Name:<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
20<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
Outside Corner Detail<br />
Job Name:<br />
SNAP-CLAD Flashing Details<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
21
Inside Corner Detail<br />
SNAP-CLAD Flashing Details<br />
Job Name:<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
22<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
Rake Detail<br />
Job Name:<br />
SNAP-CLAD Flashing Details<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
23
Head Wall Detail<br />
SNAP-CLAD Flashing Details<br />
Job Name:<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
24<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
Pitch Break Detail<br />
Job Name:<br />
SNAP-CLAD Flashing Details<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
25
Gable Detail<br />
SNAP-CLAD Flashing Details<br />
Job Name:<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
26<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
Fascia/Rake Wall Detail<br />
Job Name:<br />
SNAP-CLAD Flashing Details<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
27
Gutter Detail<br />
SNAP-CLAD Flashing Details<br />
Job Name:<br />
SNAP-CLAD Flashing Details<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
28<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
Sill Detail<br />
Job Name:<br />
SNAP-CLAD Flashing Details<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
29
Fascia to Soffit Transition<br />
SNAP-CLAD Flashing Details<br />
Job Name:<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
30<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
Fascia to Soffit Transition<br />
Job Name:<br />
SNAP-CLAD Flashing Details<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
31
Gravel Stop/Head Detail<br />
SNAP-CLAD Flashing Details<br />
Job Name:<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
32<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
Vented Ridge Detail<br />
Job Name:<br />
SNAP-CLAD Flashing Details<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
33
SNAP-CLAD Flashing Details<br />
Job Name:<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
34<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
Job Name:<br />
SNAP-CLAD Flashing Details<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
35
SNAP-CLAD Flashing Details<br />
Job Name:<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
36<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
Bearing Plate Assembly<br />
Job Name:<br />
SNAP-CLAD Flashing Details<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
37
SNAP-CLAD Flashing Details<br />
Job Name:<br />
Date:<br />
Contractor:<br />
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
38<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935
SPEC DATA ®<br />
Roof & Wall Panels 07 41 00<br />
Petersen Aluminum Corporation<br />
1. Product Name<br />
• TITE-LOC, TITE-LOC HS and TITE-LOC<br />
Plus Mechanically Seamed Panels<br />
• SNAP-CLAD Standing Seam Panels<br />
• Snap-On and High Snap-On Standing<br />
Seam Panels<br />
• Redi-Roof and Redi-Roof Batten Standing<br />
Seam Panels<br />
• Integral Standing Seam and Integral<br />
Batten Panels<br />
• Flush Panels<br />
• PAC-750 and PAC-850 Soffit Panels<br />
• Exposed Fastener Panels<br />
• Precision Series Horizontal Wall Panel<br />
2. Manufacturer<br />
Petersen Aluminum Corp.<br />
1005 Tonne Rd.<br />
Elk Grove Village, IL 60007<br />
(847) 228-7150<br />
(800) 323-1960<br />
Fax: (800) 722-7150<br />
www.pac-clad.com<br />
3. Product Description<br />
Basic Use<br />
Petersen Aluminum produces a wide variety<br />
of wall and soffit panels in addition to a complete<br />
line of metal roofing panels. All standing<br />
seam panels are corrective leveled. Standing<br />
seam, flush, exposed fastener panels and<br />
wall and soffit panels are all factory formed in<br />
continuous lengths up to 50’. Check specific<br />
profile for maximum panel length and consult<br />
with local factory for longer lengths. Matching<br />
flashing and trim can be factory or field<br />
formed from PAC-CLAD material.<br />
Materials and Finishes<br />
PAC-CLAD is a versatile prefinished sheet<br />
metal coating (Kynar 500 ® or Hylar 5000 ® ) that<br />
is applied to G90 galvanized steel, galvalume<br />
steel, or prime quality aluminum. Originally<br />
developed for use in abrasive environments,<br />
PAC-CLAD is ideally suited for roofing,<br />
curtainwall, storefront and trim applications.<br />
TITE-LOC, TITE-LOC HS and TITE-LOC Plus<br />
• 24 gauge PAC-CLAD G-90 galvanized steel<br />
• 22 gauge PAC-CLAD Galvalume steel<br />
• .032 PAC-CLAD prime quality aluminum<br />
• .040 PAC-CLAD prime quality aluminum<br />
• 24 gauge Galvalume ® Plus<br />
SNAP-CLAD Panels<br />
• 24 gauge PAC-CLAD G-90 galvanized steel<br />
• 22 gauge PAC-CLAD Galvalume steel<br />
• .032 PAC-CLAD prime quality aluminum<br />
• .040 PAC-CLAD prime quality aluminum<br />
• 16 oz cold-rolled copper<br />
• 24 gauge Galvalume ® Plus<br />
Snap-On and High Snap-On Panels<br />
• 24 gauge PAC-CLAD G-90 Galvanized steel<br />
• .032 PAC-CLAD prime quality aluminum<br />
• 24 gauge Galvalume ® Plus<br />
Redi-Roof and Redi-Roof Batten Panels<br />
• 24 gauge PAC-CLAD G-90 galvanized steel<br />
• 22 gauge PAC-CLAD Galvalume steel<br />
• .032 PAC-CLAD prime quality aluminum<br />
• 16 oz cold-rolled copper<br />
• 24 gauge Galvalume ® Plus<br />
Integral Panels<br />
• 24 gauge PAC-CLAD G-90 Galvanized Steel<br />
• .032 PAC-CLAD prime quality aluminum<br />
• 24 gauge Galvalume® Plus<br />
Flush Panels<br />
• 24 gauge PAC-CLAD G-90 galvanized steel<br />
• 22 gauge PAC-CLAD Galvalume steel<br />
• .032 PAC-CLAD prime quality aluminum<br />
• .040 PAC-CLAD prime quality aluminum<br />
• 24 gauge Galvalume® Plus<br />
PAC-750 and PAC-850 Soffit Panels<br />
• .032 PAC-CLAD prime quality aluminum<br />
Exposed Fastener Panels<br />
• 24 gauge PAC-CLAD G-90 galvanized steel<br />
• 22 gauge PAC-CLAD Galvalume steel<br />
• .032 PAC-CLAD prime quality aluminum<br />
• .040 PAC-CLAD prime quality aluminum<br />
• .050 PAC-CLAD prime quality aluminum<br />
• 24 gauge Galvalume® Plus<br />
TYPES<br />
TITE-LOC,TITE-LOC Plus and TITE-LOC HS<br />
Panels<br />
TITE-LOC panels combine structural performance<br />
with architectural panel aesthetics.<br />
A factory-applied sealant bead offers<br />
additional weather resistance. The minimum<br />
panel length is 4’ (1.2 m). TITE-LOC panels<br />
feature a 2” (51 mm) leg height that requires<br />
mechanical field seaming after installation.<br />
Panels include a concealed fastener floating<br />
clip system designed to allow for thermal<br />
expansion/contraction.<br />
All three panels carry a UL 90 classification<br />
over a wide variety of substrates and assemblies,<br />
including 5/8” (15.9 mm) plywood,<br />
purlins and rigid insulation in conjunction<br />
with bearing plates (UL design numbers 90,<br />
176, 180 238B, 437, 449, 451, 452, 487, 616,<br />
and 617).<br />
TITE-LOC and TITE-LOC HS panels are factory<br />
formed to length and field-seamed to a<br />
90 degree lock, while TITE-LOC Plus panels<br />
are designed to be field-seamed to a 180 degree<br />
lock.<br />
TITE-LOC panels are designed for application<br />
on roof slopes as low as 1/2:12 pitch.<br />
The TITE-LOC seamer is bi-directional, offering<br />
labor savings to travel up and down<br />
slope. 6:12 roof pitch is the maximum the<br />
Tite-Loc seamer will travel upslope. The<br />
TITE-LOC Plus seamer runs in one direction<br />
only and care should be taken to install panels<br />
from left to right to ensure the seamer<br />
travels downslope. The seamer will not run<br />
up slope on a roof pitch greater than 4:12.<br />
The 90 degree TITE-LOC can be fieldcurved<br />
to a minimum radius of 20’. Contact<br />
local factory for more details about curving<br />
capabilities. Additional features include:<br />
• Weathertighness warranty available<br />
• Available in four panel condition variations,<br />
check with local factory for striation<br />
and pencil rib availability<br />
• Corrective leveled<br />
SNAP-CLAD Panels<br />
Offering architectural panel aesthetics, as<br />
well as structural panel performance, SNAP-<br />
CLAD panels feature a 1 3/4” (44.5 mm) leg<br />
height and a continuous interlock for improved<br />
structural performance. A factoryapplied<br />
sealant bead provides additional<br />
weather resistance. The minimum panel<br />
length is 4’ (1.2 m).<br />
A concealed fastener clip system allows for<br />
thermal expansion/contraction while providing<br />
extraordinary hold-down strength. Two<br />
clips are available: a standard clip for most<br />
mansard and fascia applications and a highperformance<br />
clip for roofing application and<br />
UL 90 rated assemblies. SNAP-CLAD panels<br />
carry a UL 90 classification over a wide<br />
variety of substrates and assemblies, including<br />
5/8” (15.9 mm) plywood, purlins and<br />
rigid insulation in conjunction with bearing<br />
plates (UL design numbers 254, 255, 261,<br />
303, 343, 508, 508A, and 614). A minimum<br />
slope of 2:12 pitch is recommended on most<br />
applications. Additional features include:<br />
• Continuous interlock<br />
• Labor-saving one-piece design<br />
• Striations and factory eave notching<br />
• Stiffener beads<br />
• Weathertightness Warranty Available<br />
Snap-On and High Snap-On Panels<br />
These panels are designed for use in roofing,<br />
mansard and fascia applications and<br />
should be installed over a waterproofed solid<br />
substrate with a minimum 3:12 roof pitch.<br />
Factory roll formed in continuous lengths,<br />
Snap-On panels are ideal for specification<br />
on applications where roof transitions are<br />
required. The simplicity of the pan design,<br />
®<br />
SPEC-DATA<br />
SPEC-DATA® is a registered trademark of Reed Elsevier Inc. The manufacturer is responsible for technical accuracy. ©2007 Reed Construction Data.<br />
All Rights Reserved.<br />
39
®<br />
SPEC-DATA<br />
combined with inline tension leveling, provides<br />
superior flatness and allows for greater<br />
workability onsite.<br />
Both panels in steel carry a UL 90 rating for<br />
wind uplift when fastened to a solid substrate,<br />
including 5/8” (15.9 mm) plywood or<br />
OSB laminated to rigid insulation (UL design<br />
numbers 351 and 352). This is one of the few<br />
UL 90 systems that does not require sealant<br />
between plywood boards.<br />
The 1” (25.4 mm) Snap-On standing seam<br />
panel can now be curved to a concave or<br />
convex radius, with a minimum radius of 9’<br />
(2.7 m). This panel is ideal for barrel vaults<br />
and entranceways. Curved panels must<br />
be installed over a waterproofed solid substrate.<br />
The High Snap-On profile features a<br />
1 1/2” (38.1 mm) standing seam. Unlike the<br />
Snap-On panel, this panel cannot be curved.<br />
Additional features include:<br />
• Stiffener beads available<br />
Redi-Roof and Redi-Roof Batten Panels<br />
This architectural metal roofing system, which<br />
is available exclusively from Petersen Aluminum,<br />
may be specified in either batten or<br />
standing seam profile and is intended for application<br />
over a solid substrate with a minimum<br />
3:12 roof pitch. The minimum panel length is<br />
4’ (1.2 mm).<br />
Steel Redi-Roof panels carry a UL 90 rating for<br />
wind uplift when fastened to a solid substrate,<br />
including 5/8” (15.9 mm) plywood or OSB laminated<br />
to rigid insulation (UL design numbers<br />
350, 353 and 615). Additional features include:<br />
• Labor-saving one-piece design<br />
• Factory eave notching<br />
• Stiffener beads<br />
Integral Standing Seam and Integral<br />
Batten Panels<br />
PAC-CLAD Integral panels are designed for<br />
roofing applications, mansards, canopies<br />
and fascia. The one-piece design of the Integral<br />
panels minimizes labor and allows for<br />
quick and easy installation. The minimum<br />
panel length is 4’ (1.2 mm).<br />
Steel PAC-CLAD Integral panels carry a UL<br />
90 classification for wind uplift when fastened<br />
to a solid substrate, including 5/8”<br />
(15.9 mm) plywood or OSB laminated to rigid<br />
insulation (UL design numbers 346 and 347).<br />
Flush Panels<br />
PAC-CLAD Flush panels are designed for<br />
use in wall, fascia and soffit applications<br />
where a flush or flat appearance is desired.<br />
A rounded interlock leg and concealed fastening<br />
system improve the flush appearance<br />
while providing additional strength.<br />
These panels are not intended for use in roofing<br />
or mansard applications. Panels are factory-formed<br />
to length to minimize field cutting.<br />
The minimum panel length is 4’ (1.2 m). The<br />
maximum panel length is 28’ (8.4 m).<br />
The Flush panels are available with optional<br />
stiffening beads, which are recommended<br />
for longer panel lengths. One or two beads<br />
are available. Flush panels may also be<br />
specified for use as soffit panels. The soffit<br />
version of this panel is available with venting<br />
strips or perforated, in aluminum only, for increased<br />
air flow and under eave ventilation.<br />
Contact the local factory for venting options.<br />
Additional features include:<br />
• Rounded interlock leg providing improved<br />
flush fit<br />
PAC-750 and PAC-850 Soffit Panels<br />
PAC-750 preformed soffit panels are suitable<br />
for both commercial and residential<br />
use. PAC-850 soffit panels utilize an innovative<br />
hook and grab interlock. Both panels<br />
are rollformed of .032 gauge aluminum, and<br />
both panels are 12” (305 mm) wide with a<br />
“vee” groove every 6” (152 mm) center-tocenter.<br />
They are furnished in continuous<br />
lengths up to 20’ (6.1 m). Steel is not available<br />
in either profile.<br />
The PAC-750 and PAC-850 soffit panels<br />
can be perforated to allow for airflow and<br />
under eave ventilation. Both PAC-750 and<br />
PAC-850 can be specified as fully vented,<br />
half vented or solid. Petersen Aluminum can<br />
provide a soffit “J” channel as trim to match<br />
any of their soffit panels. “J” channel is available<br />
in lengths up to 12’ (3.7 m) in matching<br />
colors. Additional features include:<br />
• Perforation available for ventilation (PAC-<br />
750 and PAC-850)<br />
• Roll-formed to exact lengths<br />
Exposed Fastener Panels<br />
Petersen Aluminum offers a complete line of<br />
exposed fastener panels providing design<br />
flexibility, cost-effectiveness and aesthetics.<br />
The 7.2 Panel, R-36 Panel and 7/8” Corrugated<br />
Panels are ideal for a wide range of building<br />
envelope applications including roofs, walls,<br />
and linear panels. The R-41, M-42, M-36 and<br />
1/2” Corrugated panels are suitable for wall<br />
applications and equipment screens.<br />
The exposed fastener panels can also be<br />
produced perforated for a variety of exterior<br />
projects, such as equipment screens, or interior<br />
acoustical applications. Additional features<br />
include:<br />
• Matching screws and rivets<br />
• Closure strips available<br />
• Precut short lengths - 2’ (0.61 m) minimum<br />
Precision Series<br />
The PAC Precision Series Horizontal Wall Panels<br />
offer design flexibility, bold visual effect, cost<br />
effectiveness and easy installation. Two profiles<br />
are available: The HWP has a concealed extended<br />
screw leg and the HWPC utilizes a clip<br />
leg. Both panels can also be installed vertically<br />
in some applications, and can be specified as<br />
perforated for use in equipment screen applications.<br />
Maximum panel length is 35’.<br />
SIZES<br />
TITE-LOC, TITE-LOC HS and TITE-LOC<br />
Plus Panels<br />
• Width - 12”, 16”, 18” - (305, 406, 457 mm)<br />
• Height - 2” (51 mm)<br />
SNAP-CLAD Standing Seam Panels<br />
• Width - 10,” 12”, 16”, 18” - (254, 305, 406, 457 mm)<br />
• Height - 1 3/4” (44.5 mm)<br />
Snap-On Standing Seam Panels<br />
• Width - 12”, 18”, 19”, 20” (305, 457, 483, 508 mm)<br />
• Height - 1” (25.4 mm)<br />
Snap-On Batten Panels<br />
• Width - 11”, 12”, 18” (279, 305, 457 mm)<br />
• Height - 1 1/2” (38.1 mm)<br />
High Snap-On Panels<br />
• Width - 11”, 18,” 19” (279, 457, 483 mm)<br />
• Height - 1 1/2” (38.1 mm)<br />
Redi-Roof Standing Seam Panels<br />
• Width - 12”, 16”, 18” - (305, 406, 457 mm)<br />
• Height – 1 9/16” (40 mm) with offsets, 1<br />
3/8” (35 mm) without offsets<br />
Redi-Roof Batten Panels<br />
• Width - 12” (305 mm)<br />
• Height - 1 1/4” (32 mm)<br />
Integral Panels<br />
• Width - 11”, 12”, 18” (279, 305, 457 mm)<br />
• Height - 1 1/2” (38.1 mm)<br />
Flush Panels<br />
• Width - 7”, 11”, 12” (178, 279, 305 mm)<br />
• Height - 1” (25.4 mm)<br />
PAC-750 and PAC-850 Soffit Panels<br />
• Width - 12” (305 mm)<br />
M-42 Exposed Fastener Panels<br />
• Width - 42” (1067 mm)<br />
• Height - 3/4” (19.1 mm)<br />
M-36 Exposed Fastener Panels<br />
• Width - 36” (914 mm)<br />
• Height - 3/4” (12.7 mm)<br />
R-41 Exposed Fastener Panels<br />
• Width - 41” (1041 mm)<br />
• Height - 1 1/4” (31.8 mm)<br />
R-36 Exposed Fastener Panels<br />
• Width - 36” (914 mm)<br />
• Height - 1 1/4” (31.8 mm)<br />
7.2 Exposed Fastener Panels<br />
• Width - 36” (914 mm)<br />
• Height - 1 1/2” (38.1 mm)<br />
1/2” Corrugated Exposed Fastener Panels<br />
• Width - 40” (1016 mm)<br />
• Height - 1/2” (12.7 mm)<br />
7/8” Corrugated Exposed Fastener Panels<br />
• Width - 34.6” (879 mm)<br />
• Height - 7/8” (22.2 mm)<br />
Precision Wall Panels<br />
• Width – 12” or 16” (305, 406 mm)<br />
• Height – 7/8” (22 mm)<br />
40<br />
SPEC-DATA® is a registered trademark of Reed Elsevier Inc. The manufacturer is responsible for technical accuracy. ©2007 Reed Construction Data.<br />
All Rights Reserved.
FLASHING & TRIM<br />
All flashing and trim shall be fabricated by<br />
manufacturer or qualified fabricator. Flashing<br />
shall be PAC-CLAD aluminum (.032 - .063<br />
gauge as specified) or PAC-CLAD steel (24<br />
gauge G-90 galvanized or 22 gauge galvalume<br />
as specified). Vinyl masking is recommended<br />
on all fabrication applications<br />
where extra handling is expected. NOTE:<br />
The strippable film must be removed immediately<br />
after installation.<br />
COLORS<br />
Petersen Aluminum panels are available in<br />
the following PAC-CLAD finishes:<br />
• 24 gauge G-90 galvanized steel – 37<br />
stocked colors<br />
• 22 gauge galvalume steel – 13 stocked colors<br />
• .032 prime quality aluminum – 36<br />
stocked colors<br />
• .040 prime quality aluminum – 20<br />
stocked colors<br />
• .050 prime quality aluminum – 29<br />
stocked colors<br />
• 24 gauge Galvalume® Plus also available<br />
ACCESSORIES<br />
Petersen Aluminum fabricates a wide range<br />
of roofing accessories. Coping, gravel stops,<br />
gutters and downspouts are all formed from<br />
38 standard PAC-CLAD colors.<br />
LIMITATIONS<br />
Contact Petersen Aluminum regarding<br />
panel limitations as they pertain to your<br />
project specifics.<br />
4. Technical Data<br />
ASTM International<br />
• ASTM A653 Standard Specification for<br />
Steel Sheet, Zinc-Coated (Galvanized) or<br />
Zinc- Iron Alloy-Coated (Galvannealed) by<br />
the Hot-Dip Process<br />
• ASTM A792/A792M Standard Specification<br />
for Steel Sheet, 55 % Aluminum-Zinc<br />
Alloy- Coated by the Hot-Dip Process<br />
• ASTM B209 Standard Specification for Aluminum<br />
and Aluminum-Alloy Sheet and Plate<br />
• ASTM E283 Standard Test Method for<br />
Determining Rate of Air Leakage Through<br />
Exterior Windows, Curtain Walls, and<br />
Doors Under Specified Pressure Differences<br />
Across the Specimen<br />
• ASTM E331 Standard Test Method for<br />
Water Penetration of Exterior Windows,<br />
Skylights, Doors, and Curtain Walls by<br />
Uniform Static Air Pressure Difference<br />
• ASTM E1592 Standard Test Method for<br />
Structural Performance of Sheet <strong>Metal</strong><br />
Roof and Siding Systems by Uniform<br />
Static Air Pressure Difference<br />
• ASTM E1646 Standard Test Method for<br />
Water Penetration of Exterior <strong>Metal</strong> Roof<br />
Panel Systems by Uniform Static Air Pressure<br />
Difference<br />
• ASTM E1680 Standard Test Method for<br />
Rate of Air Leakage Through Exterior<br />
<strong>Metal</strong> Roof Panel Systems<br />
Underwriters Laboratories, Inc. (UL)<br />
• UL 263 Fire Tests of Building Construction<br />
and Materials<br />
• UL 580 Standard for Tests for Uplift Resistance<br />
of Roof Assemblies<br />
• UL 790 Standard Test Methods for Fire<br />
Tests of Roof Coverings<br />
• UL 1897 Uplift Tests for Roof Covering<br />
Systems<br />
• UL 2218 Standard for Impact Resistance<br />
of Prepared Roof Covering Materials<br />
ENVIRONMENTAL CONSIDERATIONS<br />
Where possible, Petersen Aluminum products<br />
include a high percentage of recycled<br />
material, which lowers the environmental<br />
footprint. Additionally, PAC products offer a<br />
long life span, and are 100% recyclable at<br />
the end of their extended service life, which<br />
may reduce the solid waste stream.<br />
Petersen also offers 29 finishes that are<br />
listed with the Cool Roof Ratings Council,<br />
31 finishes that are Energy Star approved,<br />
and 29 finishes that have an SRI of 29 or<br />
higher for steep slope roofs, for qualification<br />
towards credits for LEED’s Green Building<br />
Rating System.<br />
PHYSICAL PROPERTIES<br />
• TITE-LOC & TITE-LOC Plus – ASTM<br />
E331/1646 and ASTM E283/1680<br />
• SNAP-CLAD - ASTM E331/1646 and<br />
ASTM E283/1680<br />
• Snap On & High Snap-On - ASTM<br />
E331/1646 and ASTM E283/1680 (when<br />
applied over a solid substrate)<br />
• Redi-Roof & Redi-Roof Batten - ASTM<br />
E331/1646 and ASTM E283/1680 (when<br />
applied over a solid substrate)<br />
• Integral Panels - ASTM E331/1646 and<br />
ASTM E283/1680 (when applied over a<br />
solid substrate)<br />
• Flush Panels – ASTM E330<br />
• PAC 850 – ASTM E330<br />
• Precision Wall Series – ASTM E330,<br />
ASTM E283, ASTM E331, AAMA 501.1-05<br />
Test reports are available to design professionals<br />
upon request.<br />
5. Installation<br />
PREPARATORY WORK<br />
Handle and store products according to<br />
manufacturer’s recommendations.<br />
Deliver materials in manufacturer’s original,<br />
unopened, undamaged containers with<br />
identification labels intact. Store materials<br />
protected from exposure to harmful environmental<br />
conditions and at temperature<br />
and humidity conditions recommended by<br />
the manufacturer.<br />
Verify that site conditions are acceptable for<br />
installation. Do not proceed with installation<br />
until unacceptable conditions are corrected.<br />
METHODS<br />
Contact Petersen Aluminum for complete<br />
installation information.<br />
PRECAUTIONS<br />
In coastal applications, Petersen Aluminum<br />
recommends that stainless steel clips be<br />
used with prefinished aluminum in lieu of<br />
prefinished steel.<br />
BUILDING CODES<br />
Current data on building code requirements<br />
and product compliance can be obtained<br />
from Petersen Aluminum technical support<br />
specialists. Installation must comply with<br />
the requirements of all applicable local, state<br />
and national code jurisdictions.<br />
6. Availability & Cost<br />
AVAILABILITY<br />
Contact manufacturer for information on local<br />
availability.<br />
COST<br />
Budget installed cost information can be obtained<br />
from the manufacturer upon request.<br />
7. Warranty<br />
A full 20-year pro-rated finish warranty is<br />
available covering cracking, peeling and color<br />
fade on all PAC-CLAD applications. Finish<br />
warranty terms for Cardinal Red, Award Blue<br />
and Interstate Blue, and all metallic finishes,<br />
as well as embossed finishes, vary slightly.<br />
Please refer to www.pac-clad.com for further<br />
details.<br />
8. Maintenance<br />
Maintenance is not required. The panel finish<br />
is a member of the Teflon® family and is<br />
selfcleaning. If cleaning is desired, panels<br />
can be washed with mild soap and water followed<br />
by a clean water rinse.<br />
9. Technical Services<br />
Technical services are available from Petersen<br />
Aluminum Corp. and regional architectural<br />
representatives.<br />
10. Filing Systems<br />
• Reed First Source®<br />
• MANU-SPEC®<br />
• Additional product information is available<br />
from the manufacturer upon request.<br />
®<br />
SPEC-DATA<br />
SPEC-DATA® is a registered trademark of Reed Elsevier Inc. The manufacturer is responsible for technical accuracy. ©2007 Reed Construction Data.<br />
All Rights Reserved.<br />
41
PAC-CLAD Color Availability<br />
®<br />
SPEC-DATA<br />
PAC-CLAD Standard Reflectivity Emissivity 3 Year<br />
Exposure<br />
SRI*<br />
Steel<br />
24ga. 22ga.<br />
Aluminum<br />
.032 .040 .050 .063<br />
Almond 0.56 0.83 0.57 64 √ √ √ √ √ •<br />
Arcadia Green 0.33 0.84 0.32 33 √ √ •<br />
Bone White 0.71 0.85 0.71 86 √ √ √ √ √ √ •<br />
Cardinal Red 0.42 0.84 0.41 45 √ √ √ •<br />
Charcoal 0.28 0.84 0.28 27 √ √ √ •<br />
Cityscape 0.37 0.85 0.34 39 √ √ √ √ •<br />
Colonial Red 0.34 0.85 0.33 35 √ √ √ √ •<br />
Dark Bronze 0.27 0.85 0.26 26 √ √ √ √ √ √ •<br />
Evergreen 0.27 0.85 0.25 26 √ √ •<br />
Granite* 0.36 0.84 0.35 37 √ √ √ √ √ •<br />
Hemlock Green 0.30 0.85 0.31 30 √ √ √ √ •<br />
Hunter Green 0.26 0.84 0.26 24 √ √ •<br />
Mansard Brown 0.26 0.84 0.24 24 √ √ √ √ √ •<br />
Medium Bronze 0.30 0.85 0.29 30 √ √ √ √ √ √ •<br />
Military Blue 0.29 0.84 0.28 28 √ √ •<br />
Musket Gray 0.32 0.84 0.31 32 √ √ √ √ •<br />
Patina Green 0.34 0.85 0.33 35 √ √ •<br />
Sandstone 0.51 0.83 0.51 57 √ √ √ √ √ √ •<br />
Sierra Tan 0.38 0.85 0.35 40 √ √ √ √ √ •<br />
Slate Blue 0.25 0.84 0.27 23 √ √ •<br />
Slate Gray 0.38 0.84 0.37 40 √ √ √ √ √ •<br />
Stone White 0.61 0.86 0.59 72 √ √ √ √ √ √ •<br />
Teal 0.26 0.85 0.26 24 √ √ •<br />
Terra Cotta 0.37 0.84 0.37 39 √ √ √ •<br />
PAC-CLAD <strong>Metal</strong>lic<br />
Aged Copper 0.27 0.83 0.25 25 √ √ √ •<br />
Champagne 0.45 0.78 0.41 57 √ √ √ √ •<br />
Copper Penny 0.45 0.82 0.42 49 √ √ √ √ •<br />
Silver 0.53 0.80 0.51 59 √ √ √ √ •<br />
Weathered Zinc 0.27 0.80 0.27 23 √ √ √ •<br />
Zinc 0.30 0.85 0.30 30 √ √ √ √ •<br />
Galvalume Plus** 0.68 0.14 0.55 57 √<br />
Energy<br />
Star®<br />
PAC-CLAD Standard Colors (do not meet cool roof requirements)<br />
Award Blue √ √ √<br />
Berkshire Blue* 0.25 0.84 0.22 23 √ •<br />
Burgundy √ √ √<br />
Forest Green √ √ √ √ √<br />
Hartford Green √ √ √ √<br />
Interstate Blue √ √ √<br />
Matte Black √ √ √ √ √<br />
Midnight Bronze<br />
√<br />
PAC-CLAD® <strong>Metal</strong>lic finishes are available from stock at a moderate extra cost. PAC-CLAD® Copper Penny is a Non-Weathering finish.<br />
Solar Reflectance Index calculated according to ASTM C-1549. *Low Gloss/Low Sheen,full Kynar 500® or Hylar 5000® finish **Acrylic coated, non-Kynar Finish.<br />
42<br />
SPEC-DATA® is a registered trademark of Reed Elsevier Inc. The manufacturer is responsible for technical accuracy. ©2007 Reed Construction Data.<br />
All Rights Reserved.
Notes:<br />
PETERSEN ALUMINUM CORPORATION<br />
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935<br />
43
www.pac-clad.com / email: sales@petersenmail.com<br />
HQ: 1005 Tonne Road<br />
Elk Grove Village, IL 60007<br />
P: 800-PAC-CLAD<br />
F: 800-722-7150<br />
9060 Junction Drive<br />
Annapolis Junction, MD 20701<br />
P: 800-344-1400<br />
F: 301-953-7627<br />
10551 PAC Road<br />
Tyler, TX 75707<br />
P: 800-441-8661<br />
F: 903-581-8592<br />
102 Northpoint Pkwy<br />
Acworth, GA 30102<br />
P: 800-272-4482<br />
F: 770-420-2533<br />
350 73rd Ave., NE Suite 1<br />
Fridley, MN 55432<br />
P: 877-571-2025<br />
F: 866-901-2935