B l u e R i d g e<br />

T e c h n o l o g i e s<br />

<strong>Capacitive</strong> <strong>Touch</strong> <strong>Station</strong> <strong>DDN</strong><br />

Project Part Number Ref.<br />

Data Sheet<br />

Overview<br />

<strong>Capacitive</strong> <strong>Touch</strong> <strong>Station</strong>s (CTS-<strong>DDN</strong>) provide local occupant overrides on<br />

the <strong>DDN</strong> Network. CTS-<strong>DDN</strong> are available in Channel On/Off configuration<br />

with one or two button layouts. The CTS-<strong>DDN</strong> interface features LED and<br />

audible chirp indication as well as schedule transition warnings. CTS-<strong>DDN</strong><br />

fit decorator style wall plates, are gang-able with other devices, and are<br />

available in four standard colors.<br />

Features<br />

Compatible with <strong>DDN</strong> Network<br />

Available in Black, Gray, Light Almond, or White<br />

Fits decorator style wall plates<br />

Gang-able with other decorator style devices<br />

Extended life cycle<br />

• No moving switch parts<br />

• LED indicator<br />

General Specifications<br />

Construction: Acrylic face, ABS/polycarbonate back box / mounting frame<br />

Dimensions:<br />

<strong>Station</strong>: 4.13”(105mm)H x 1.75”(44mm)W x 1.13”(29mm)D<br />

<strong>Capacitive</strong> <strong>Touch</strong> Surface: 0.5”(13mm)H x 0.5”(13mm)W per button<br />

Weight: 3oz (85g)<br />

Mounting: Standard single gang or multi-gang switch box, (2) #6/32 screws<br />

(included), and Decorator style wall plate (not included)<br />

Operating Environment: 32-125°F (0-50°C), 20-95%RH, non-condensing<br />

Warranty<br />

Two (2) year limited manufacturer warranty from date of shipment<br />

(extended warranty optional)<br />

Low Voltage Specification<br />

CTS-<strong>DDN</strong> Power / Draw: 24VDC / 15mA<br />

Legacy Low Voltage Specifications<br />

<strong>DDN</strong> Switch and Input Module Power / Draw: 24VDC / 20mA<br />

<strong>DDN</strong> Network Specifications<br />

Protocol: Digital Device Network (<strong>DDN</strong>)<br />

Maximum Unique Button Addresses: 60<br />

Address: DIP switch selectable<br />

Topology: Daisy Chain Wiring (no stars or t-taps)<br />

Wire Requirement: CL3P, 22AWG, 4 conductor, Unshielded<br />

Maximum Length: 2,000’(610m)<br />

Network Termination: DIP switch<br />

<strong>Station</strong> Specifications<br />

Button Layout Channel On/Off: 1, 2<br />

Button Operation: Momentary On/Off<br />

Indicator Operation<br />

Audible Indication: Chirp when button is pressed<br />

LED Status Indication: LED is on when associated lighting is on.<br />

LED Schedule Transition Warning: Rapid blinking<br />

Button Configuration<br />

Each Unique Button Address is assigned to the lighting group of the<br />

same number.<br />

3-way / 4-way Operation: Requires CTS-<strong>DDN</strong> with same button layout.<br />

Accomplished by using same button address (may require additional power).


Field Devices<br />

<strong>DDN</strong> Network<br />

Relay Panel (RP)<br />

Field Devices<br />

<strong>DDN</strong> Network<br />

Retrofit Interior (RI)<br />

Field Devices<br />

<strong>DDN</strong> Network<br />

Retrofit Kit (RK)<br />

<strong>Capacitive</strong> <strong>Touch</strong> <strong>Station</strong> <strong>DDN</strong><br />

www.BRTint.com : 800-241-9173 <strong>Blue</strong> <strong>Ridge</strong> <strong>Technologies</strong>® © 2014 <strong>Blue</strong> <strong>Ridge</strong> <strong>Technologies</strong> International, LLC All Rights Reserved. MD-CTS<strong>DDN</strong>-DS-V14.02<br />

General Architecture<br />

<strong>DDN</strong> Network<br />

CTS-<strong>DDN</strong><br />

Field Devices<br />

LVS OCC LS5<br />

CTS-<strong>DDN</strong> (<strong>Capacitive</strong> <strong>Touch</strong> <strong>Station</strong>)<br />

LVS (Low Voltage Switch) / OCC (Occupancy Sensor) / LS5 (Light Sensor)<br />

Data Sheet<br />

Internet<br />

IP<br />

BAS Protocol<br />

BAS<br />

BAS Router<br />

Field Devices<br />

<strong>DDN</strong> Network<br />

Relay Panel (RP)<br />

<strong>DDN</strong> Network<br />

Field Devices<br />

<strong>DDN</strong> Network<br />

Retrofit Interior (RI)<br />

Field Devices<br />

Field Devices<br />

<strong>DDN</strong> Network<br />

Retrofit Kit (RK)<br />

CTS-<strong>DDN</strong><br />

LVS OCC LS5<br />

CTS-<strong>DDN</strong> (<strong>Capacitive</strong> <strong>Touch</strong> <strong>Station</strong>)<br />

LVS (Low Voltage Switch) / OCC (Occupancy Sensor) / LS5 (Light Sensor)<br />

General Architecture<br />

Internet<br />

IP<br />

BAS Protocol<br />

BAS<br />

BAS Router<br />

Controller Terminations<br />

24<br />

H<br />

L<br />

G<br />

General Architecture<br />

CL3P / 22AWG / 4 Conductor<br />

Unsheilded<br />

<strong>DDN</strong> Network Structure<br />

From RI / RK / RP<br />

BAS BAS Router<br />

Field Devices<br />

<strong>DDN</strong> Network<br />

<strong>DDN</strong> Network<br />

Relay Panel (RP)<br />

CTS Lead<br />

CTS-<strong>DDN</strong> (<strong>Capacitive</strong> <strong>Touch</strong> <strong>Station</strong>)<br />

Daisy Chain Only<br />

Field Devices<br />

Field Devices<br />

<strong>DDN</strong> Network<br />

<strong>DDN</strong> Network<br />

<strong>DDN</strong> Network Structure<br />

Retrofit Interior (RI)<br />

Retrofit Kit (RK)<br />

24VDC (Red)<br />

Signal (+) (Green)<br />

Field Devices<br />

From RI / RK / RP<br />

Signal (-) (White)<br />

Ground (Black)<br />

CTS-<strong>DDN</strong> LVS<br />

OCC LS5<br />

Daisy Chain Only<br />

CTS-<strong>DDN</strong><br />

LVS (Low Voltage Switch) / OCC (Occupancy Sensor) / LS5 (Light Sensor)<br />

Button Layout Options<br />

Internet<br />

IP<br />

BAS Protocol<br />

Field Devices<br />

<strong>DDN</strong> Network CTS-<strong>DDN</strong><br />

Button Layout Options 1-Button Terminations Relay Panel (RP)<br />

<strong>DDN</strong> Network<br />

Field Devices<br />

Field Devices<br />

<strong>DDN</strong> Network<br />

<strong>DDN</strong> Network<br />

2-Button Retrofit Terminations Interior (RI)<br />

Ordering Information 1-Button Retrofit Kit to (RK) Controller<br />

MDCTS XXX - XX - <strong>DDN</strong><br />

Field Devices<br />

Terminations<br />

General Architecture<br />

White<br />

BAS BAS Router<br />

Common<br />

MDCTS1CH-XX-<strong>DDN</strong> T3<br />

T1<br />

Controller Switch Terminations<br />

1<br />

1-Button to Controller T2<br />

1<br />

G<br />

Light<br />

Almond<br />

Switch 1<br />

Common<br />

Field Devices<br />

<strong>DDN</strong> Network<br />

T1<br />

CTS-<strong>DDN</strong> (<strong>Capacitive</strong><br />

Switch<br />

<strong>Touch</strong><br />

1<br />

<strong>Station</strong>)<br />

MDCTS2CH-XX-<strong>DDN</strong><br />

Grey<br />

Relay Panel (RP)<br />

1<br />

Switch 1<br />

CTS-<strong>DDN</strong> LVS OCC G<br />

LS5<br />

Common<br />

Common<br />

Black<br />

Field Devices<br />

<strong>DDN</strong> Network<br />

Channel T1 Quantity<br />

LVS (Low Voltage Switch)<br />

XXX Switch<br />

/ OCC<br />

= 1CH1<br />

(Occupancy Sensor) / LS5 (Light Sensor)<br />

1 Channel (On-Off)<br />

T3<br />

Retrofit Interior (RI)<br />

Switch 2<br />

Color<br />

Internet<br />

T2 Options<br />

2CH 2 Channels (On-Off)<br />

2-Button to Controller<br />

XX = WH White 1<br />

GR Grey 2<br />

BL Black<br />

G<br />

LA Light Almond<br />

Field Devices<br />

<strong>DDN</strong> Network<br />

Retrofit Kit (RK)<br />

Switch 1<br />

Switch 2<br />

Common<br />

IP<br />

BAS Protocol