INDICATIVE ROOF DETAILING – R DETAILS<br />

37<br />

R9<br />

GABLE LADDER<br />

R10<br />

BLOCKING AND VENTILATION HOLES<br />

Double joist may be required<br />

when L exceeds <strong>JJI</strong>-Joist<br />

spacing (S)<br />

Outrigger notched and<br />

nailed around <strong>JJI</strong>-Joist<br />

flange, spacing not to<br />

exceed 600mm<br />

S<br />

Maximum<br />

overhang same<br />

as rafter spacing<br />

L<br />

1/3 1/3 1/3<br />

2/3<br />

Maximum permissible ventilation<br />

hole in <strong>JJI</strong>-<strong>Joists</strong> blocking<br />

1/3 1/3 1/3<br />

1/2<br />

1/2<br />

Maximum permissible ventilation<br />

V-cut for solid blocking<br />

1/3 1/3 1/3<br />

1/3<br />

1/3<br />

1/3<br />

Gable wall<br />

panel<br />

Alternatively, gable ladder to be made from <strong>JJI</strong>-<strong>Joists</strong><br />

Solid timber blocking<br />

pieces to suit or<br />

blockwork built up<br />

Braced by Simpson HSA<br />

or Cullen TJS straps<br />

Maximum permissible hole zone for<br />

round, square or rectangular holes<br />

Vertical BJ-Beam blocking<br />

panels may be site trimmed to<br />

match <strong>JJI</strong>-Joist depth at outer<br />

edge of wall or positioned on<br />

wall to match <strong>JJI</strong>-Joist depth<br />

R11<br />

FLUSH PURLIN BEAM<br />

R12<br />

RAFTER FIXING TO WALL PLATE<br />

Restraint Strap<br />

(Cullen S or Simpson LSTA)<br />

Framing<br />

Anchor<br />

BJ-Beam Purlin<br />

or equivalent<br />

Twisted<br />

restraint<br />

strap<br />

Full depth face<br />

fix hanger<br />

(See detail F18)<br />

Approved angle bracket<br />

connector fixed to both<br />

sides of joist<br />

Ply/timber bevelled<br />

web stiffener required<br />

on each face. Fix in<br />

accordance with F22<br />

Roof connectors to be determined by Roof Designer<br />

R13<br />

RAFTER TERMINATING ON DOWNSTAND<br />

RIDGE BEAM<br />

R14<br />

RAFTER TERMINATING ON DOWNSTAND<br />

STEEL BEAM<br />

Double bevelled<br />

support plate<br />

Fixing of rafter to support<br />

plate to <strong>Build</strong>ing<br />

Designer’s specification<br />

Bevelled bearing timber attached<br />

to top of steel as per <strong>Build</strong>ing<br />

Designers specification<br />

Strap nailed to<br />

the side face of<br />

bottom flange<br />

and face of<br />

void filler<br />

Approved restraint strap<br />

(Cullen RST2 or<br />

Simpson H10T15)<br />

Timber void filler<br />

required. Fixing to<br />

<strong>Build</strong>ing Designer’s<br />

specification<br />

<strong>JJI</strong>-Joist/BJ-Beam blocking panels<br />

(For ventilation guidance, see detail R10)<br />

<strong>JJI</strong>-Joist/BJ-Beam ridge<br />

beam or support wall<br />

One strap required on each side of the rafter bottom flange