<strong>Ground</strong> <strong>Fault</strong><br />

<strong>Circuit</strong> <strong>Protection</strong><br />

www.<strong>carlingtech</strong>.<strong>com</strong>


Transforming Customer Needs into Customer Solutions<br />

Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical<br />

<strong>com</strong>ponents, they engineer powerful solutions! By working closely with a customer’s product team and<br />

understanding the requirements of the specific application, Carling’s product experts can tailor switching<br />

and circuit protection solutions to meet any customer’s needs—cost effectively.<br />

Since the <strong>com</strong>pany was founded in 1920, there are few products that Carling Technologies hasn’t<br />

turned “ON” and fewer industries that haven’t turned to Carling for solutions. With five ISO registered<br />

manufacturing facilities and technical sales offices worldwide, Carling now ranks among the world’s largest,<br />

privately owned manufacturers of hydraulic magnetic circuit breakers, thermal circuit breakers, electrical<br />

switches, electronic switches, miniature switches, power distribution centers, digital switching systems and<br />

electronic controls.<br />

Globally, there are over 2,000 employees working for Carling, providing solutions to customers’ application<br />

needs with innovation, value, and world-class service for both standard and custom products. Carling’s<br />

breadth and depth of standard product offerings gives customers literally millions of configuration choices<br />

to meet the demands of its Strategic Markets:<br />

• Marine<br />

• Military<br />

• Renewable Energy<br />

• Tele<strong>com</strong>/Data<strong>com</strong><br />

• Transportation<br />

Additional markets served by Carling products include: Audio Visual, Commercial Food Equipment,<br />

Commercial HVAC, Floor Care, Generators, Industrial Control, Kitchen & Small Appliances, Security Systems,<br />

Test & Measurement equipment, among others.<br />

If the standard product does not meet the application requirements, the engineering team at Carling has<br />

the expertise to customize solutions faster and more creatively thanks in measure to over ninety years of<br />

experience as an innovative <strong>com</strong>pany that manufactures a diverse range of products. The Carling Sales,<br />

Service and Engineering teams work closely with the customer’s engineering team to advance a custom<br />

project from initial concept to final design and product release, respecting both quality and cost through<br />

out the process. With extensive field knowledge and resources available, Carling Technologies can ensure<br />

that the products created for the customer are of superior quality from the start, thus avoiding costly<br />

secondary operations or modifications. Carling’s <strong>com</strong>mitment to excellence consistently delivers “Quality by<br />

Design,” the <strong>com</strong>pany mission.<br />

Carling has an extensive network of Sales Representatives and Distributors to assist with Carling products,<br />

or contact a Carling Technologies’ Technical Sales Representative to design innovative, cost-effective,<br />

quality engineered solutions that exceed the tough demands of today’s applications.<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


Table of Contents<br />

2<br />

8<br />

16<br />

21<br />

PB–Series<br />

General Specifications<br />

Dimensional Specifications<br />

Wiring Diagrams<br />

Ordering Scheme<br />

PC–Series<br />

General Specifications<br />

Dimensional Specifications<br />

Wiring Diagrams<br />

Dimensions<br />

Time Delay Curves<br />

Ordering Scheme<br />

PD–Series<br />

General Specifications<br />

<strong>Circuit</strong> & Terminal Diagrams<br />

Ordering Scheme<br />

Thermal <strong>Circuit</strong> Breaker - Selector Guide<br />

GFCI/ELCI<br />

This catalog features Carling Technologies’ current line of GFCIs/ELCIs products, which offer<br />

maximum equipment protection against overload and short circuits.<br />

Carling’s Equipment leakage circuit breakers function as hydraulic/magnetic circuit breakers,<br />

offering customized overload and short circuit protection. In addition, they sense and guard<br />

against faults to ground using innovative electronics technologies. With the exception of small<br />

amounts of leakage, the current returning to the power supply will be equal to the current<br />

leaving the power supply. If the difference between the current leaving and returning through<br />

the earth leakage circuit breaker exceeds the leakage sensitivity setting, the breaker trips and<br />

its LED illuminates. The LED gives a clear indication that the trip occurred as a result of leakage<br />

to ground. This protection helps prevent serious equipment damage and fire.<br />

Typical Applications:<br />

• Marine<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


2 | PB-Series - Introduction<br />

PB-Series<br />

<strong>Ground</strong> <strong>Fault</strong> <strong>Circuit</strong> <strong>Protection</strong><br />

The PB-Series utilizes the hydraulic magnetic principle<br />

which provides precise operation and performance<br />

even when exposed to extremely hot and/or cold<br />

application environments.<br />

The new PB-Series, AC Residual Current <strong>Circuit</strong> Breaker<br />

with Overcurrent <strong>Protection</strong> (RCBO), <strong>com</strong>bines the<br />

ground fault protection of a GFCI with the familiar<br />

overcurrent tripping characteristics of a normal circuit<br />

breaker.<br />

These precision mechanisms are temperature stable<br />

and are not adversely affected by temperature<br />

changes in their operating environment. As such,<br />

derating considerations due to temperature variations<br />

are not normally required, and heat-induced nuisance<br />

tripping is avoided.<br />

Features:<br />

• Overload, short circuit and ground fault protection<br />

in a single package<br />

• Handle or rocker style actuators<br />

• Wiping Contacts - Mechanical linkage with twostep<br />

actuation – cleans contacts, provides high,<br />

positive contact pressure & longer contact life.<br />

• A trip-free mechanism, a safety feature which<br />

makes it impossible to manually hold the contacts<br />

closed during overload or fault conditions.<br />

• A <strong>com</strong>mon trip linkage between all poles, another<br />

safety feature, ensures that an overload in one pole<br />

will trip all adjacent poles.<br />

• Front panel mounting<br />

• Integral push-to-test button<br />

Benefits:<br />

• Increases safety around boats and marinas<br />

• Protects against electrical shock hazards in<br />

areas near water<br />

• Protects against defects in wires & conductors<br />

• Reduces fire and shock hazards from defects in<br />

permanently installed appliances such as water<br />

heaters, battery chargers, lighting fixtures, etc.<br />

• Detects lower level ground faults which do not<br />

trip ordinary circuit breakers, but can lead to<br />

fires, and shock hazards for boating occupants<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


PB-Series <strong>Circuit</strong> Breaker - General Specifications | 3<br />

Electrical Tables<br />

Table A: UL Listed configurations and performance capabilities<br />

as <strong>Circuit</strong> Breakers<br />

1000<br />

Electrical<br />

Maximum Voltage<br />

Current Ratings<br />

Insulation Resistance<br />

0.1<br />

Dielectric Strength<br />

O<br />

H<br />

M<br />

S<br />

1000<br />

100<br />

10<br />

1<br />

0.1<br />

0.01<br />

0.001<br />

0.01<br />

100<br />

VOLTS HERTZ (AMPS)<br />

O<br />

H<br />

M<br />

S<br />

10<br />

RESISTANCE, IMPEDANCE VALUES<br />

from Line to Load Terminals<br />

(Values Based on Series Trip <strong>Circuit</strong> Breaker)<br />

Impedance<br />

0.1 1 10 100<br />

AMPERE RATING<br />

CURRENT TOLERANCE<br />

(AMPS)<br />

(%)<br />

Leakage 0.100 - 5.0To ± 15% <strong>Ground</strong><br />

5.1 - 20.0 ± 25%<br />

20.1 - 30.0 ± 35%<br />

Standard Must Trip<br />

FIGURE 1<br />

Leakage Current Ratings<br />

Trip Time<br />

Test Button<br />

RESISTANCE, IMPEDANCE VALUES<br />

from Line to Load Terminals<br />

Endurance<br />

(Values Based on Series Trip <strong>Circuit</strong> Breaker)<br />

Multiple of<br />

Rated Current<br />

AMPERE RATING<br />

Ampere Rating<br />

CURRENT<br />

(AMPS)<br />

0.100 - 5.0<br />

5.1 - 20.0<br />

20.1 - 30.0<br />

12x<br />

I r<br />

FIGURE 1<br />

60 Hz 1/2 Cycle<br />

Inrush Pulse Tolerance<br />

4.165<br />

8.33<br />

TOLERANCE<br />

(%)<br />

± 15%<br />

± 25%<br />

± 35%<br />

Pulse Tolerance Curve<br />

Time Delay Curves<br />

22, 24, 26<br />

t<br />

16.67<br />

Time in<br />

Milliseconds<br />

Mechanical<br />

Trip Free<br />

Trip Indication<br />

120/240VAC 60 Hz<br />

Standard current coils: 0.100, 0.250,<br />

0.500, 0.750, 1.00, 2.50, 5.00, 7.50,<br />

1 10.0, 15.0, 20.0, 25.0 & 30.0 amps.<br />

Other ratings available, see ordering<br />

scheme.<br />

Minimum of 100 Megohms at 500<br />

VDC.<br />

UL, CUL - 1500 V 60 Hz for one<br />

minute between all electrically isolated<br />

terminals. PB-Series circuit breakers<br />

0.01<br />

<strong>com</strong>ply with the 8mm spacing and<br />

3750V 60 Hz dielectric requirements<br />

from hazardous voltage to operator<br />

0.001 accessible surfaces and between<br />

0.01 adjacent 0.1poles<br />

1 10 100 Shock<br />

Values from Line to Load Terminal.<br />

5 & 30 milliamps.<br />

5± 1mA for UL943, other leakage<br />

ratings test to UL1053.<br />

For other ratings, consult factory.<br />

300 ms Max. @ 100%, 40ms Max. @<br />

500% of must trip leakage current.<br />

On unit face along side of actuator.<br />

Physical<br />

Number of Poles<br />

Internal <strong>Circuit</strong> Config.<br />

Weight<br />

Standard Colors<br />

Environmental<br />

Designed and tested in accordance with requirements of<br />

specification MIL-PRF- 55629 and MIL-STD-202 as follows:<br />

Vibration<br />

Moisture Resistance<br />

Salt Spray<br />

Thermal Shock<br />

Operating Temperature<br />

Corrosion<br />

Agency Certifications<br />

UL Listed<br />

UL Standard 489<br />

UL Standard 1077<br />

UL Standard 943<br />

UL Standard 1053<br />

10,000 ON-OFF operations @ 6<br />

per minute; with rated Current and<br />

Voltage.<br />

All PB-Series <strong>Circuit</strong> Breakers will<br />

trip on overload or ground fault, even<br />

when Handle is forcibly held in the ON<br />

position.<br />

The operating Handle moves<br />

positively to the OFF position when an<br />

overload or ground fault causes the<br />

breaker to trip.<br />

1 - 3 poles, where the third pole is<br />

neutral<br />

Series Trip<br />

Approximately 65 grams/pole. (2.32<br />

ounces/pole.)<br />

Housing- Black; Actuator - See<br />

Ordering Scheme.<br />

Withstands 100 Gs, 6ms, sawtooth while<br />

carrying rated current per Method 213,<br />

Test Condition “I”. Ultra-short curves<br />

tested @ 90% of rated current.<br />

Withstands 0.060” excursion from<br />

10-55 Hz, and 10 Gs 55-500 Hz, at<br />

rated current per Method 204C, Test<br />

Condition A. Instantaneous and<br />

ultrashort curves tested at 90% of rated<br />

current.<br />

Method 106D, i.e., ten 24-hour cycles @<br />

+ 25°C to +65°C, 80-98% RH.<br />

Method 101, Condition A (90-95% RH @<br />

5% NaCl Solution, 96 hrs).<br />

Method 107D, Condition A (Five cycles<br />

@ -55°C to +25°C to +85°C to +25°C).<br />

-35° C to +65° C<br />

Tested per UL943 FMG Test. 3 weeks @<br />

30°C 75% RH, 100ppb H2S, 20ppb CI2,<br />

200ppb NO2<br />

<strong>Circuit</strong> Breakers, Molded Case,<br />

(Guide DIVQ, File E129899)<br />

Supplementary Protectors<br />

Class A <strong>Ground</strong> <strong>Fault</strong> <strong>Circuit</strong> Interruptors<br />

<strong>Ground</strong> <strong>Fault</strong> Sensing and Relaying<br />

Equipment<br />

*Manufacturer reserves the right to change product specification without prior notice.<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


SCALE<br />

0.500<br />

SCALE 0.500<br />

4 | PB-Series – Dimensional Specifications<br />

INDICATE "ON"<br />

3.03<br />

[ 76.9]<br />

1.25<br />

[ 31.6]<br />

1.515 MAX<br />

[38.48]<br />

.21<br />

[ 5.3]<br />

TEST<br />

LINE<br />

LOAD<br />

INDICATE<br />

"OFF"<br />

AND<br />

SINGLE<br />

COLOR<br />

2.17<br />

[ 55.0]<br />

1-POLE 120 VAC VERSION<br />

LOAD<br />

TEST<br />

LINE<br />

#6-32/M3 MOUNTING INSERTS<br />

LINE TERMINAL<br />

1.88<br />

[ 47.8]<br />

2.265 MAX<br />

[57.53]<br />

2.58<br />

[ 65.6]<br />

CURRENT TRANSFORMERS<br />

1.660<br />

[ 42.16]<br />

.39<br />

[ 9.9]<br />

TEST<br />

2.37<br />

[ 60.2]<br />

.375<br />

[ 9.53]<br />

1.500 +.020<br />

-.000<br />

38.10 +.50<br />

-.00<br />

[ ]<br />

.750 TYP<br />

[ 19.05]<br />

LOAD TERMINAL<br />

GFCI NEUTRAL WIRE<br />

2-POLE 120/240 VAC VERSION<br />

.20<br />

[ 5.1]<br />

Ø.156<br />

TYP<br />

[ 3.96]<br />

1.260<br />

[ 32.00]<br />

1.660<br />

[ 42.16]<br />

2.250 +.020<br />

-.000<br />

57.15 +.50<br />

-.00<br />

[ ]<br />

PANEL CUTOUT<br />

NEUTRAL BREAK POLE<br />

.750 TYP<br />

[19.05]<br />

3.015 MAX<br />

[76.58]<br />

TEST<br />

2-POLE 120/240 VAC WITH NEUTRAL BREAK<br />

Notes:<br />

1 All dimensions are in inches [millimeters].<br />

2 Tolerance ±.020 [.51] unless otherwise specified.<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


PB-Series – Dimensional Specifications | 5<br />

Notes:<br />

1 All dimensions are in inches [millimeters].<br />

2 Tolerance ±.020 [.51] unless otherwise specified.<br />

Time Delay Curves<br />

Instantaneous<br />

Medium<br />

Short<br />

Long<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


6 | PB-Series – Wiring Diagrams<br />

120VAC with Switched Neutral<br />

SYSTEM NEUTRAL<br />

120VAC without Switched Neutral<br />

SYSTEM NEUTRAL<br />

GFCI<br />

MODULE<br />

PIGTAIL<br />

GFCI<br />

MODULE<br />

PIGTAIL<br />

LOAD<br />

HOT<br />

LOAD<br />

NEUTRAL<br />

LOAD<br />

HOT<br />

LINE/SOURCE<br />

(HOT)<br />

LINE/SOURCE<br />

(HOT)<br />

LINE/SYSTEM<br />

NEUTRAL<br />

120 VAC<br />

LOAD<br />

120 VAC<br />

LOAD<br />

AC SOURCE<br />

AC SOURCE<br />

120 VAC WITHOUT SWITCHED NEUTRAL<br />

120 VAC WITH SWITCHED NEUTRAL<br />

120 VAC WITHOUT SWITCHED NEUTRAL<br />

120 VAC WITHOUT SWITCHED<br />

NEUTRAL<br />

120/240VAC with Switched Neutral<br />

SYSTEM<br />

NEUTRAL<br />

120/240VAC without Switched Neutral<br />

SYSTEM<br />

NEUTRAL<br />

GFCI<br />

MODULE<br />

PIGTAIL<br />

GFCI<br />

MODULE<br />

PIGTAIL<br />

LOAD<br />

HOT<br />

1<br />

LOAD<br />

HOT<br />

2<br />

LOAD<br />

NEUTRAL<br />

LOAD<br />

HOT<br />

1<br />

LOAD<br />

HOT<br />

(2)<br />

120 VAC<br />

LOAD<br />

120 VAC<br />

LOAD<br />

LINE/SOURCE 1<br />

LINE/<br />

SOURCE<br />

2<br />

LINE/SYSTEM<br />

NEUTRAL<br />

120 VAC<br />

LOAD<br />

120 VAC<br />

LOAD<br />

LINE/SOURCE<br />

(1)<br />

LINE/<br />

SOURCE<br />

(2)<br />

240 VAC LOAD<br />

240 VAC LOAD<br />

AC SOURCE<br />

AC SOURCE<br />

120 VAC WITHOUT SWITCHED NEUTRAL<br />

120 VAC WITHOUT SWITCHED NEUTRAL<br />

120/240 VAC WITH SWITCHED NEUTRAL<br />

120/240 VAC WITHOUT SWITCHED NEUTRAL<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


PB-Series – Ordering Scheme | 7<br />

PB A — B A — 24 — 620 — 2 B A — A G<br />

1<br />

Series<br />

2<br />

System<br />

Voltage/Poles<br />

3<br />

<strong>Circuit</strong><br />

4<br />

Actuator<br />

5<br />

Frequency<br />

& Delay<br />

6<br />

Current Rating<br />

7<br />

Terminal<br />

8<br />

Actuator<br />

Color<br />

9<br />

Mounting/<br />

Barriers<br />

10<br />

Trip Level<br />

11<br />

Agency<br />

Approval<br />

1 SERIES<br />

PB<br />

2 SYSTEM VOLTAGE / POLES<br />

A 120 VAC single phase, one pole<br />

B 120/240 VAC single phase, two pole<br />

C 120/240 VAC single phase with switched neutral, three pole<br />

D 120 VAC two pole with switched neutral<br />

3 CIRCUIT<br />

B Series Trip (Current)<br />

4 ACTUATOR 1<br />

Handle<br />

A one per pole<br />

B one per multipole unit<br />

Two Color Curved Visi-Rocker<br />

C Indicate ON,<br />

vertical legend<br />

D Indicate ON,<br />

horizontal legend<br />

F Indicate OFF,<br />

vertical legend<br />

G Indicate OFF,<br />

horizontal legend<br />

Single Color Curved Rocker<br />

J Vertical legend<br />

K Horizontal legend<br />

Two Color Flat Visi-Rocker<br />

1 Indicate OFF,<br />

vertical legend<br />

2 Indicate OFF,<br />

horizontal legend<br />

Single Color Flat Rocker<br />

3 Vertical legend<br />

4 Horizontal legend<br />

7 TERMINAL 2<br />

1 3 Push-On 0.250 Tab (Q.C.)<br />

2 Screw 8-32 w/upturned lugs<br />

3 Screw 8-32 (Bus Type)<br />

4 Screw 10-32 w/upturned lugs<br />

5 Screw 10-32 (Bus Type)<br />

9 MOUNTING/BARRIERS<br />

MOUNTING STYLE<br />

Threaded Insert, 2 per pole<br />

A 6-32 X 0.195 inches<br />

B ISO M3 x 5mm<br />

B<br />

C<br />

E<br />

H<br />

8 ACTUATOR COLOR & LEGEND<br />

Acuator Color<br />

White<br />

Black<br />

Red<br />

Green<br />

Blue<br />

Yellow<br />

Gray<br />

Orange<br />

I-O<br />

A<br />

C<br />

F<br />

H<br />

K<br />

M<br />

P<br />

R<br />

ON-OFF<br />

B<br />

D<br />

G<br />

J<br />

L<br />

N<br />

Q<br />

S<br />

Screw M5 w/upturned lugs<br />

Screw M4 w/upturned lugs<br />

Screw M4 (Bus Type)<br />

Screw M5 (Bus Type)<br />

BARRIERS<br />

yes<br />

yes<br />

Dual<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

10 LEAKAGE CURRENT TRIP LEVEL - MAX. TRIP CURRENT<br />

A 5 MA (CLASS A GFCI) 3,4,5<br />

E 30 MA (ELCB)<br />

Legend Color<br />

Black<br />

White<br />

White<br />

White<br />

White<br />

Black<br />

Black<br />

Black<br />

11 AGENCY APPROVAL<br />

G UL489 Listed, CSA Certified<br />

C UL1077<br />

I UL1077/UL1500 Ignition Protected, CSA Certified 6<br />

5 FREQUENCY & DELAY<br />

22 60Hz Short<br />

24 60Hz Medium<br />

26 60Hz Long<br />

6 CURRENT RATING (AMPERES)<br />

CODE<br />

AMPERES<br />

210 0.100<br />

215 0.150<br />

220 0.200<br />

225 0.250<br />

230 0.300<br />

235 0.350<br />

240 0.400<br />

245 0.450<br />

250 0.500<br />

255 0.550<br />

260 0.600<br />

265 0.650<br />

270 0.700<br />

275 0.750<br />

280 0.800<br />

285 0.850<br />

290 0.900<br />

295 0.950<br />

410 1.000<br />

512 1.250<br />

415 1.500<br />

517 1.750<br />

420 2.000<br />

522 2.250<br />

425 2.500<br />

527 2.750<br />

430 3.000<br />

435 3.500<br />

440 4.000<br />

445 4.500<br />

450 5.000<br />

455 5.500<br />

460 6.000<br />

465 6.500<br />

470 7.000<br />

475 7.500<br />

480 8.000<br />

485 8.500<br />

490 9.000<br />

495 9.500<br />

610 10.000<br />

710 10.500<br />

611 11.000<br />

711 11.500<br />

612 12.000<br />

712 12.500<br />

613 13.000<br />

614 14.000<br />

615 15.000<br />

616 16.000<br />

617 17.000<br />

618 18.000<br />

620 20.000<br />

622 22.000<br />

624 24.000<br />

625 25.000<br />

630 30.000<br />

Notes:<br />

1 Actuator Code:<br />

A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.<br />

B: Handle location as viewed from front of breaker:2 pole - left pole 3 pole - center pole<br />

2 Screw Terminals are re<strong>com</strong>mended on ratings greater than 20 amps.<br />

3 Available with leakage current trip level - Max trip current code E, and agency approval C.<br />

4 6mA per UL943, available with agency approval code G.<br />

5 30mA per UL1053, available with agency approval codes C & G.<br />

6 UL1500 only available with 30MA trip level.<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


8 | PC-Series - Introduction<br />

PC-Series<br />

<strong>Ground</strong> <strong>Fault</strong> <strong>Circuit</strong> <strong>Protection</strong><br />

The PC-Series, AC Residual Current <strong>Circuit</strong> Breaker with<br />

Overcurrent <strong>Protection</strong> (RCBO), <strong>com</strong>bines the ground<br />

fault protection of a GFCI with the familiar overcurrent<br />

tripping characteristics of a normal circuit breaker.<br />

The PC-series utilizes the hydraulic magnetic principle<br />

which provides precise operation and performance<br />

even when exposed to extremely hot and/or cold<br />

application<br />

environments.<br />

Features:<br />

• Overload, short circuit and ground fault protection<br />

in a single package<br />

• Handle style actuators and rocker style “acuguard”<br />

• Wiping Contacts - Mechanical linkage with twostep<br />

actuation – cleans contacts, provides high,<br />

positive contact pressure & longer contact life<br />

• A trip-free mechanism, a safety feature which<br />

makes it impossible to manually hold the contacts<br />

closed during overload or fault conditions.<br />

• A <strong>com</strong>mon trip linkage between all poles, another<br />

safety feature, ensures that an overload in one pole<br />

will trip all adjacent poles.<br />

• Front panel mounting<br />

• Integral push-to-test button<br />

• Two integrated LED indicators distinguish if a<br />

breaker is closed with Line Voltage present, or has<br />

opened due to leakage current, or has opened due<br />

to over current, or is closed with no Line Voltage<br />

present.<br />

• Optional Hot/Neutral reversal detection and<br />

protection<br />

Benefits:<br />

• Increases safety around boats and marinas<br />

• Protects against electrical shock hazards in<br />

areas near water<br />

• Protects against defects in the wires &<br />

conductors<br />

• Reduces fire and shock hazards from defects in<br />

permanently installed appliances such as water<br />

heaters, battery chargers, lighting fixtures, etc.<br />

• Detects low level ground faults, which do not<br />

trip ordinary circuit breakers, that can lead to<br />

fires and shock hazards for boating occupants<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


PC-Series <strong>Circuit</strong> Breaker - General Specifications | 9<br />

Electrical Tables<br />

Table A: Lists UL Listed configurations as a <strong>Ground</strong> <strong>Fault</strong> <strong>Circuit</strong><br />

Interruptor<br />

CIRCUIT<br />

CONFIGURATION<br />

SERIES<br />

PC SERIES TABLE A : LISTS UL LISTED CONFIGURATIONS AS A GROUND FAULT CIRCUIT INTERRUPTOR<br />

VOLTAGE<br />

CURRENT<br />

RATING<br />

SHORT CIRCUIT<br />

CAPACITY<br />

GROUND<br />

FAULT TRIP<br />

LEVEL<br />

MAX.<br />

RATING<br />

FREQUENCY PHASE AMPS AMPS MILLIAMPS NOTES<br />

120 50 / 60 1 1 - 50 5000 6 1 or 2 Poles. One pole of a two pole unit must be Neutral<br />

120/240 50 / 60 1 1 - 50 5000 6 2 or 3 Poles. One pole of a three pole unit must be Neutral<br />

Table B: Lists UL Listed and Recognized as an Earth Leakage<br />

<strong>Circuit</strong> Interruptor - 120 and 120/240V<br />

PC SERIES TABLE B : LISTS UL LISTED AND RECOGNIZED CONFIGURATIONS AS AN EARTH LEAKAGE CIRCUIT INTERRUPTOR - 120 and 120/240V<br />

GROUND<br />

CURRENT SHORT CIRCUIT<br />

VOLTAGE<br />

FAULT TRIP<br />

RATING CAPACITY<br />

LEVEL<br />

CIRCUIT<br />

CONFIGURATION<br />

MAX.<br />

RATING<br />

FREQUENCY PHASE AMPS AMPS MILLIAMPS NOTES<br />

SERIES<br />

120 50 / 60 1 1 - 50 5000 30 1 or 2 Poles. One pole of a two pole unit must be Neutral<br />

120/240 50 / 60 1 1 - 50 5000 30 2 or 3 Poles. One pole of a three pole unit must be Neutral<br />

SERIES 120 50 / 60 1 1 - 50 3000 30 1 or 2 Poles. One pole of a two pole unit must be Neutral<br />

IGNITION PROTECTED 120/240 50 / 60 1 1 - 50 5000 30 2 or 3 Poles. One pole of a three pole unit must be Neutral<br />

Table C: Lists UL Listed and Recognized as an Earth Leakage<br />

<strong>Circuit</strong> Interruptor - 240V<br />

CIRCUIT<br />

CONFIGURATION<br />

PC SERIES TABLE C : LISTS UL LISTED AND RECOGNIZED CONFIGURATIONS AS AN EARTH LEAKAGE CIRCUIT INTERRUPTOR - 240V<br />

GROUND<br />

CURRENT SHORT CIRCUIT<br />

VOLTAGE<br />

FAULT TRIP<br />

RATING CAPACITY<br />

LEVEL<br />

MAX.<br />

RATING<br />

FREQUENCY PHASE AMPS AMPS<br />

MILLIAMPS<br />

SERIES 240 50 / 60 1 1 - 30 5000 30 2 or 3 Poles. One pole of a three pole unit must be Neutral. Suffix 11<br />

SERIES IGNITION PROTECTED 240 50 / 60 1 1 - 50 3000 30 2 or 3 Poles. One pole of a three pole unit must be Neutral. Suffix 12<br />

NOTES<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


10 | PC-Series <strong>Circuit</strong> Breaker - General Specifications<br />

Electrical<br />

Current Ratings<br />

Voltage Rating<br />

Current Trip Level<br />

Current Trip Time<br />

Operating Frequency<br />

Interrupt Capacity<br />

Impedence<br />

Innovative Features<br />

Indicator<br />

Neutral <strong>Protection</strong><br />

Test Button<br />

20.1 - 50.0<br />

*Manufacturer reserves the right to change product specification without prior notice.<br />

1 - 50 Amps maximum<br />

120VAC, 120/240VAC, 240VAC<br />

30mA & 6mA<br />

For 30mA leakage trip:<br />

≤ 22.2mA, shall not trip<br />

30mA, shall trip within .10 seconds<br />

The above <strong>com</strong>plies with UL-1053<br />

& ABYC E11. For 6mA leakage<br />

trip: ≤25ms<br />

The above <strong>com</strong>plies with UL-943.<br />

50/60 Hz for 30mA leakage trip<br />

60 Hz for 6mA leakage trip<br />

5,000 Amps<br />

Two integrated LEDs, Red & Green<br />

• Green LED On, Red LED Off<br />

Line Voltage is present, the<br />

breaker is closed, and the device<br />

is protecting the circuits against<br />

over current and leakage current.<br />

• Green LED Off, Red LED On<br />

The device has detected leakage<br />

current and has opened the cicuit<br />

breaker.<br />

• Green LED Flashing, Red LED Off<br />

The circuit breaker has opened due<br />

to over current or has been turned off<br />

manually<br />

• Green LED Off, Red LED Off<br />

Line Voltage is not present<br />

• Green LED Flashing, Red LED<br />

Off, Amber LED ON<br />

Indicates Hot & Neutral are reversed<br />

and the circuit breaker is open<br />

When neutral is grounded on load<br />

side of circuit<br />

Located on <strong>Ground</strong> <strong>Fault</strong> Module<br />

Mechanical<br />

Endurance<br />

Trip Free<br />

Physical<br />

Number of Poles<br />

(Breakers only)<br />

Termination<br />

Mounting<br />

Actuator<br />

Environmental<br />

Designed and tested in accordance with requirements of<br />

specification MIL-PRF- 55629 and MIL-STD-202G as follows:<br />

Shock<br />

Withstands 100 G, 6ms, sawtooth at<br />

rated current per Method 213, Test<br />

Condition “I”.<br />

Vibration<br />

Withstands 0.06” excursion from 10-<br />

55 Hz, and 10 G 55-500 Hz, at rated<br />

current per Method 204C, Test Condition<br />

A. Instantaneous and ultrashort curves<br />

tested at 90% of rated current.<br />

Moisture Resistance 93% RH at 30°C for 168 Hours.<br />

Operating Temperature -35°C to +66°C<br />

Corrosion<br />

UL-943-6.21, 3 weeks<br />

Humidity:<br />

30±2°C, 70±2% relative humidity<br />

Mixed Flowing Gases:<br />

100 ppb H2S, 20 ppb CI2,<br />

200±50 ppb NO2<br />

Agency Certifications<br />

UL Listed<br />

UL Standard 489<br />

UL Standard 1077<br />

UL Standard 943<br />

UL Standard 1053<br />

UL Standard 1500<br />

10,000 ON-OFF operations @ 6<br />

per minute; with rated Current and<br />

Voltage.<br />

Trips on short circuit, overload or<br />

leakage to ground, even when<br />

actuator is forcibly held in the “On”<br />

position<br />

1-pole (1 <strong>Circuit</strong> Breaker + 1<br />

GFCISensor Module), 120V<br />

2-pole (2 <strong>Circuit</strong> Breakers + 1 GFCI<br />

Sensor Module), 120/240V or 120V<br />

with Neutral Break. 240VAC two pole<br />

3-pole 120/240V with Neutral Break<br />

(Sensor module has 2 pole width)<br />

<strong>Circuit</strong> Breaker Line Side: #10-32,<br />

Threaded stud.<br />

GFCI Sensor Module Load Side: #10-<br />

32 threaded stud. Neutral pigtail.<br />

Front Panel, #6-32 and M3 threaded<br />

inserts.<br />

Handle, Flat Rocker, Curved Rocker<br />

(with or without rocker guard),<br />

Push-to-Reset Rocker<br />

<strong>Circuit</strong> Breakers, Molded Case,<br />

(Guide DIVQ, File E129899)<br />

Supplementary Protectors<br />

Class A <strong>Ground</strong> <strong>Fault</strong> <strong>Circuit</strong><br />

Interruptors<br />

<strong>Ground</strong> <strong>Fault</strong> Sensing and Relaying<br />

Equipment<br />

Ignition <strong>Protection</strong><br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


PC-Series – Wiring Diagrams | 11<br />

1 2 3 4<br />

INDICATE OFF / SINGLE COLOR<br />

ROCKER ACTUATOR<br />

HANDLE / INDICATE ON<br />

ROCKER ACTUATOR<br />

TERMINAL<br />

LOCATIONS<br />

I<br />

D<br />

PCA<br />

120 VAC<br />

VERSION<br />

PCE<br />

120 VAC VERSIO<br />

W/ REVERSE POLA<br />

INDICATOR<br />

C<br />

PCB<br />

120/240 VAC<br />

VERSION<br />

PCF<br />

120/240 VAC VERSIO<br />

W/ REVERSE POLARI<br />

INDICATOR<br />

3.015<br />

[76.58]<br />

MAX.<br />

B<br />

PCC<br />

120/240 VAC<br />

VERSION<br />

W/ NEUTRAL BREAK<br />

3.775<br />

[95.88]<br />

MAX.<br />

A<br />

PCD<br />

120 VAC<br />

VERSION<br />

W/NEUTRAL BREAK<br />

1 2 3 4<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


PC-Series ELCI/RCBO Instruction Bulletin<br />

12 | PC-Series – Wiring Diagrams & Panel Cut Out<br />

voltage. Can cause death or serious injury. Turn off<br />

pply before installing PC-Series ELCI/RCBO.<br />

t a line to line fault<br />

of the<br />

st MINAL instructions<br />

ATIONS<br />

d applications.<br />

sures.<br />

or hi-pot test.<br />

fore hi-potting<br />

ect. 550-12, NEC).<br />

ns.<br />

d by a qualified<br />

to enclosure in<br />

.<br />

or.<br />

wires to the Load<br />

Fig. A for terminal<br />

e wires directly to<br />

e Terminals.<br />

nd mount front<br />

aker actuator.<br />

structions.<br />

l in a convenient<br />

instruct equipment<br />

portance of<br />

tests.<br />

urn on the power<br />

flashing and the<br />

e green “POWER”<br />

d the red<br />

off.<br />

4 5 6 7 8<br />

LOAD NEUTRAL<br />

3. Depress the “TEST” button. This will cause the actuator to<br />

move to the “OFF” position and the red LED to turn on and<br />

show steady illumination, indicating that the ELCI/RCBO is<br />

functioning properly. The green LED will also go from<br />

steady to off. If the actuator fails to move to the “OFF”<br />

position or INDICATE the red OFF LED / fails SINGLE to illuminate, COLOR the<br />

HANDLE<br />

unit MUST<br />

/ INDICATE ON<br />

ROCKER ACTUATOR<br />

ROCKER ACTUATOR<br />

be replaced.<br />

4. Turn the ELCI/RCBO actuator to the “ON” position. The<br />

red LED should turn off and only the green LED should be<br />

illuminated.<br />

5. This test is to be performed on a monthly basis and<br />

recorded on the “Monthly Test Reminder” label.<br />

PCE<br />

120 WHEN VAC VERSION ELCI/RCBO TRIPS:<br />

W/ REVERSE The PC-Series POLARITY ELCI/RCBO opens the circuit when there is an<br />

over INDICATOR current or ground fault condition. If the red LED is<br />

continuously illuminated the tripping is due to a ground fault<br />

condition. If the green LED is flashing, the tripping is due to an<br />

over current:<br />

1. Some faults are self-clearing. Try resetting the breaker<br />

once.<br />

2. If this device is installed as a main breaker, turn off all<br />

branch breakers and reset the breaker. If it does not trip,<br />

turn branch breakers on one at a time to locate the fault.<br />

3. If the breaker continues to trip with the branch breakers off<br />

recheck that the neutral is not grounded on the load side<br />

of the ELCI circuit breaker.<br />

4. If the breaker continues to trip, but no grounding of the<br />

PCF<br />

120/240 VAC<br />

neutral<br />

VERSION<br />

is observed, disconnect all load side connections<br />

W/ REVERSE and POLARITY reset the breaker. If the breaker still trips with no load<br />

INDICATOR connections in place, the breaker may be defective.<br />

5. If the breaker does not trip with the loads disconnected but<br />

does trip when the loads are connected, the device is<br />

performing its intended protection function, which means<br />

that a hazardous condition could exist. A qualified<br />

electrician should be called to evaluate the circuit and<br />

perform more advanced troubleshooting if the problem<br />

cannot be located.<br />

NOTE: NEUTRAL & GROUND PIGTAIL WIRES - SUPPLIED 12" LONG MIN. (CIRCUIT CODES A,B,E & F)<br />

PANEL CUTOUT ROCKER<br />

PANEL CUTOUT HANDLE<br />

TERMINAL<br />

LOCATIONS<br />

DRAWING FILE NO.<br />

CLA-8112<br />

REV<br />

X<br />

REVISIONS<br />

DESCRIPTION<br />

X<br />

DWG REV<br />

01<br />

DATE<br />

X<br />

3.790 [96.27]<br />

3.040 [77.22]<br />

2.280 [57.91]<br />

.156 DIA. [Ø3.96]<br />

2 PLC'S. TYP.<br />

PER POLE<br />

3.040 [77.22]<br />

2.280 [57.91]<br />

LINE 1<br />

LINE 2<br />

SOURCE<br />

NEUTRAL<br />

2.062 [52.37]<br />

1.453 [36.91]<br />

LINE 1<br />

LINE 2<br />

1.660 [42.16]<br />

1.260 [32.00]<br />

MATERIAL:<br />

ASSEMBLY<br />

FINISH:<br />

OT 2<br />

AD HOT 1<br />

LINE 1<br />

1-Phase 120 / 240 VAC<br />

with Neutral Switching<br />

LINE 2<br />

SOURCE<br />

NEUTRAL<br />

.432 [10.97]<br />

.750 [19.05]<br />

LOAD HOT 2 TYP.<br />

OR 230V NEUTRAL PCA<br />

LOAD HOT 1<br />

PCB, PCD & PCE<br />

PCC & LINE PCF 1<br />

LINE 2<br />

OR 230V NEUTRAL<br />

HANDLE ACTUATOR<br />

1-Phase 240VAC<br />

IST-0010<br />

Rev. C<br />

.200 [5.08]<br />

PANEL CUTOUT DETAIL<br />

PROPRIETARY NOTICE<br />

NOTICE TO ALL PERSONS RECEIVING THIS<br />

TOLERANCES DRAWING. ±.005 THIS [.12] DOCUMENT IS THE PROPERTY OF<br />

CARLING TECHNOLOGIES, INC. AND IS NOT TO BE<br />

DISCLOSED, REPRODUCED IN WHOLE OR IN<br />

PART OR USED FOR MANUFACTURING PURPOSES<br />

BY ANYONE WITHOUT THE CONSENT OF<br />

CARLING TECHNOLOGIES, INC.<br />

PCA, PCB<br />

PCD & PCE<br />

CONTROL SYMBOLS<br />

.XXX<br />

PCC & PCF<br />

ROCKER ACTUATOR<br />

DRAWING VERSION<br />

CRITICAL DIM.<br />

CRITICAL CHAR.<br />

TOOL NO.<br />

REV.<br />

1 01.16<br />

REFERENCE NO.<br />

PR5055-400<br />

INTRALINK MODEL<br />

PR5055-400-12<br />

INTRALINK MODEL REVISION/VERSION<br />

X<br />

DRAWING INTERPRETATIONS<br />

PROJECTIONS<br />

DIMENSIONS<br />

INCHES<br />

[MILLIMETERS]<br />

UNSPECIFIED TOLERANCES<br />

X.XXX ± .005 [0.13] FRAC. ± 1/64 [0.4]<br />

X.XX ± .01 [0.25] ANGLES ± 1 °<br />

MODELED BY: CHECKED BY: SCALE<br />

TAF<br />

DRAWN BY:<br />

APPROVED BY:<br />

DATE DRAWN:<br />

04-May-10<br />

DATE APPROVED:<br />

DO NOT SCALE DRAWING<br />

TITLE<br />

C SERIES ELCI ASSEMBLY<br />

DRAWING FILE NO.<br />

Carling Technologies<br />

Innovative Designs, Powerful Solutions<br />

0.750<br />

SIZE<br />

D<br />

DRAWING REV.<br />

CLA-8112 01<br />

PRODUCT SERIES: C SHEET 5 OF 5<br />

4 5 6 7 8<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


PC-Series – Dimensions | 13<br />

1 2 3 4 5<br />

2.265<br />

[57.53]<br />

MAX.<br />

1.510<br />

[38.35] 0.430<br />

2.975<br />

[10.92]<br />

[75.57]<br />

0.275<br />

[6.99]<br />

0.750<br />

TYP.<br />

[19.05]<br />

3.800<br />

[96.52]<br />

2.518<br />

[63.96]<br />

2.062<br />

[52.37]<br />

1.453<br />

[36.91]<br />

0.429<br />

[10.91]<br />

0.350<br />

[8.89]<br />

NEUTRAL PIGTAIL (CIRCUIT<br />

CODE A+B ONLY)<br />

#6/32 / M3 MOUNTING INSERTS<br />

0.125<br />

[3.18]<br />

1.245<br />

1.660 [31.62]<br />

[42.16]<br />

0.208<br />

[5.28]<br />

0.100<br />

[2.54]<br />

1 2 3 4 5<br />

Notes:<br />

For additional circuit breaker dimensions, reference the C-Series Breakers in the<br />

Carling <strong>Circuit</strong> <strong>Protection</strong> catalog<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


14 | PC-Series –Time Delay Curves<br />

Time Delay Curves<br />

Instantaneous<br />

Medium<br />

Ultra Short<br />

Long<br />

Short<br />

Notes:<br />

Other time delay values available, consult factory.<br />

Delay Curves 21,22,24,26: Breakers to hold 100% and must trip at 125% of rated<br />

current and greater within the time limit shown in this curve.<br />

Delay Curve 20: Breakers to hold 100% and must trip at 150% of rated current<br />

and greater within the time limit shown in this curve.<br />

All Curves: Curve data shown represents breaker response at ambient temperature<br />

of 77°F (25°C) with no preloading. Breakers are mounted in standard<br />

wall-mount position.<br />

The minimum inrush pulse tolerance handling capability is 12 times the rated current.<br />

These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse.<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


PC-Series – Ordering Scheme | 15<br />

PC B — B A — 24 — 620 — 1 B A — A 10<br />

1<br />

Series<br />

2<br />

System<br />

Voltage/Poles<br />

3<br />

<strong>Circuit</strong><br />

4<br />

Actuator<br />

5<br />

Frequency<br />

& Delay<br />

6<br />

Current Rating<br />

7<br />

Terminal<br />

8<br />

Actuator<br />

Color<br />

9<br />

Mounting/<br />

Barriers<br />

10<br />

Trip Level<br />

11<br />

Agency<br />

Approval<br />

1 SERIES<br />

PC<br />

2 SYSTEM VOLTAGE / POLES<br />

A 120 VAC single phase, one pole<br />

B 120/240 VAC single phase, two pole<br />

C 120/240 VAC single phase with switched neutral, three pole<br />

D 120 VAC single phase with switched neutral, two pole<br />

E 120 VAC single phase with reversed polarity indicator, two pole<br />

F 120/240 VAC single phase with reversed polarity indicator, three pole<br />

G 240 VAC single phase, two pole<br />

3 CIRCUIT<br />

B Series Trip (Current)<br />

4 ACTUATOR<br />

Handle<br />

A one per pole<br />

B one per multipole unit<br />

Two Color Curved Visi-Rocker<br />

C Indicate ON,<br />

vertical legend<br />

D Indicate ON,<br />

horizontal legend<br />

F Indicate OFF,<br />

vertical legend<br />

G Indicate OFF,<br />

horizontal legend<br />

Single Color Curved Rocker<br />

J Vertical legend<br />

K Horizontal legend<br />

Two Color Curved Visi-Rocker<br />

Push-to-Reset<br />

N Vertical legend<br />

O Horizontal legend<br />

5 FREQUENCY & DELAY<br />

20 50/60Hz Instantaneous<br />

21 50/60Hz Ultra Short<br />

22 50/60Hz Short<br />

24 50/60Hz Medium<br />

26 50/60Hz Long<br />

Single Color Curved Rocker<br />

Push-to-Reset<br />

R Vertical legend<br />

U Horizontal legend<br />

Two Color Flat Visi-Rocker<br />

1 Indicate OFF,<br />

vertical legend<br />

2 Indicate OFF,<br />

horizontal legend<br />

Single Color Flat Rocker<br />

3 Vertical legend<br />

4 Horizontal legend<br />

Two Color Flat Visi-Rocker<br />

Push-to-Reset<br />

5 Indicate OFF,<br />

vertical legend<br />

6 Indicate OFF,<br />

horizontal legend<br />

Single Color Flat Rocker<br />

Push-to-Reset<br />

7 Vertical legend<br />

8 Horizontal legend<br />

Notes:<br />

1 This device meets the requirements of ABCY E11.<br />

2 6mA per UL943, available with agency approval code 10.<br />

3 30mA per UL1053, available with agency approval codes 11 & 12.<br />

4 AIC Rating at 120 VAC 3kA, at 120/240 VAC 5kA<br />

6 CURRENT RATING (AMPERES)<br />

CODE<br />

AMPERES<br />

210 0.100<br />

215 0.150<br />

220 0.200<br />

225 0.250<br />

230 0.300<br />

235 0.350<br />

240 0.400<br />

245 0.450<br />

250 0.500<br />

255 0.550<br />

260 0.600<br />

265 0.650<br />

270 0.700<br />

275 0.750<br />

280 0.800<br />

7 TERMINAL<br />

1 Stud, 10-32 threaded<br />

285 0.850<br />

290 0.900<br />

295 0.950<br />

410 1.000<br />

512 1.250<br />

415 1.500<br />

517 1.750<br />

420 2.000<br />

522 2.250<br />

425 2.500<br />

527 2.750<br />

430 3.000<br />

435 3.500<br />

440 4.000<br />

445 4.500<br />

8 ACTUATOR COLOR & LEGEND<br />

Acuator Color<br />

White<br />

Black<br />

Red<br />

Green<br />

Blue<br />

Yellow<br />

Gray<br />

Orange<br />

I-O<br />

A<br />

C<br />

F<br />

H<br />

K<br />

M<br />

P<br />

R<br />

ON-OFF<br />

B<br />

D<br />

G<br />

J<br />

L<br />

N<br />

Q<br />

S<br />

450 5.000<br />

455 5.500<br />

460 6.000<br />

465 6.500<br />

470 7.000<br />

475 7.500<br />

480 8.000<br />

485 8.500<br />

490 9.000<br />

495 9.500<br />

610 10.000<br />

710 10.500<br />

611 11.000<br />

711 11.500<br />

612 12.000<br />

10 LEAKAGE CURRENT TRIP LEVEL - MAX. TRIP CURRENT<br />

A 5 MA (CLASS A GFCI) 2<br />

E 30 MA (ELCB) 1,3<br />

11 AGENCY APPROVAL<br />

AA W/O Approvals<br />

10 UL 943 2<br />

11 UL 1053 1,3<br />

12 UL 1053 & UL 1500 1,3,4<br />

Dual<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9 MOUNTING/BARRIERS<br />

MOUNTING STYLE<br />

Threaded Insert, 2 per pole<br />

A 6-32 X 0.195 inches<br />

B ISO M3 x 5mm<br />

Rockerguard Bezel<br />

Threaded Insert, 2 per pole<br />

C 6-32 X 0.195 inches<br />

D ISO M3 x 5mm<br />

Standard Bezel with Recessed Off-Side Flat Rocker<br />

Threaded Insert, 2 per pole<br />

E 6-32 X 0.195 inches<br />

F ISO M3 x 5mm<br />

Push-to-Reset Bezel<br />

Threaded Insert, 2 per pole<br />

G 6-32 X 0.195 inches<br />

H ISO M3 x 5mm<br />

712 12.500<br />

613 13.000<br />

614 14.000<br />

615 15.000<br />

616 16.000<br />

617 17.000<br />

618 18.000<br />

620 20.000<br />

622 22.000<br />

624 24.000<br />

625 25.000<br />

630 30.000<br />

635 35.000<br />

640 40.000<br />

650 50.000<br />

Legend Color<br />

Black<br />

White<br />

White<br />

White<br />

White<br />

Black<br />

Black<br />

Black<br />

BARRIERS<br />

yes<br />

yes<br />

yes<br />

yes<br />

yes<br />

yes<br />

yes<br />

yes<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


16 | PD-Series - Introduction<br />

PD-Series<br />

<strong>Ground</strong> <strong>Fault</strong> <strong>Circuit</strong> <strong>Protection</strong><br />

SmartGuard is an equipment ground fault protection<br />

device that functions as a standard high-quality<br />

Carling hydraulic/magnetic circuit breaker, offering<br />

customized overload and short circuit protection.<br />

In addition, this breaker senses and guards against<br />

faults to ground using a state of the art integrated<br />

circuit developed by Carling. This new technology<br />

detects faults and when a fault occurs, the breaker<br />

trips and an LED illuminates. The LED gives a clear<br />

indication that the trip occurred as a result of leakage.<br />

This protection helps prevent serious equipment<br />

damage and fire.<br />

Features:<br />

• Overload, short circuit and ground fault protection<br />

in a single package<br />

• Handle style actuators with optional<br />

“handleguard”<br />

• Wiping Contacts - Mechanical linkage with twostep<br />

actuation – cleans contacts, provides high,<br />

positive contact pressure & longer contact life<br />

• A trip-free mechanism, a safety feature which<br />

makes it impossible to manually hold the contacts<br />

closed during overload or fault conditions.<br />

• A <strong>com</strong>mon trip linkage between all poles, another<br />

safety feature, ensures that an overload in one<br />

pole will trip all adjacent poles.<br />

• Front panel or DIN rail mounting options<br />

• “State of the art” integrated circuit developed by<br />

Carling<br />

• Equipment leakage sensitivity from 10 to 100<br />

milliamps<br />

• Integral push-to-test button and LED “tripped”<br />

indicator<br />

• Immediate reset after fault has been cleared<br />

Agency Certifications:<br />

UL Standard 1077 Component Recognition<br />

Program as Equipment<br />

Leakage <strong>Circuit</strong> Interrupter<br />

and, Protectors, Supplementary<br />

(FTTJ2, File E177510).<br />

UL Standard 943 Tested as <strong>Ground</strong> <strong>Fault</strong> <strong>Circuit</strong><br />

Interrupters for Equipment<br />

<strong>Protection</strong>.<br />

CSA Certified Component Equipment Leakage<br />

Current Interrupter with<br />

Supplementary Protector, under<br />

Class C22.2,No. 144-M91, File<br />

LR47848-50<br />

TUV Certified IEC 947-2 and appendix B: <strong>Circuit</strong><br />

Breakers incorporating Residual<br />

Current <strong>Protection</strong>. Complies<br />

with waveform requirements of<br />

IEC 1008-1, Type A.<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


PD-Series <strong>Circuit</strong> Breaker - General Specifications | 17<br />

Electrical Tables<br />

Table A: Lists UL Recognized & CSA Certified configurations<br />

and performance capabilities as a Component Supplementary<br />

Protector.<br />

Table B: Lists TUV Certified configurations and performance<br />

capabilities as a <strong>Circuit</strong> breaker incorporating residual current<br />

protection.<br />

PD-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTOR & EARTH LEAKAGE CURRENT INTERRUPTER<br />

INTERRUPTING LEAKAGE<br />

VOLTAGE<br />

CURRENT RATING<br />

CAPACITY (AMPS) CURRENT<br />

FULL GENERAL UL / CSA MUST - TRIP<br />

FREQUENCY<br />

CIRCUIT MAX RATING LOAD PURPOSE WITHOUT RATING<br />

CONFIGURATION VOLTS HERTZ PHASE AMPS AMPS BACKUP FUSE (MILLIAMPS)<br />

120/208 50/60 1 1-50 --- 5000 7-100<br />

120/208 50/60 31 1-50 --- 5000 7-100<br />

SERIES<br />

208-240 50/60 3 1-50 --- 2000 7-100<br />

480Y 50/60 3 1-30 30.1-50 2000 7-100<br />

Electrical<br />

Maximum Voltage AC, 480<br />

Standard Current Ratings<br />

Insulation Resistance<br />

Dielectric Strength<br />

Resistance, Impedance<br />

RESISTANCE, IMPEDANCE VALUES<br />

from Line to Load Terminals<br />

WYE/277 VAC, 50/60 Hz<br />

1.00, 2.50, 5.00, 7.50, 10.0, 15.0,<br />

20.0, 25.0, 30.0, 35.0, 40.0 & 50.0<br />

amps. For other ratings, consult factory.<br />

Minimum of 100 Megohms @ 500 VDC.<br />

1960 VAC, 60 Hz for one minute<br />

between all electrically isolated<br />

terminals.<br />

From Line to Load Terminal<br />

(Values Based on Series Trip <strong>Circuit</strong><br />

Breaker)<br />

Ampere Rating<br />

Mechanical<br />

Endurance<br />

Trip Free<br />

Trip Indication<br />

10,000 ON-OFF operations @ 6 per<br />

minute; with rated current and voltage.<br />

All SmartGuard equipment leakage<br />

circuit breakers will trip on overload<br />

or leakage to ground, even when<br />

actuator is forcibly held in the ON<br />

position.<br />

The actuator moves to the OFF<br />

position when an overload or earth<br />

leakage ground fault causes the<br />

breaker to trip. The LED is illuminated<br />

when leakage to ground causes the<br />

circuit breaker to trip.<br />

Leakage To <strong>Ground</strong><br />

Standard Must Trip<br />

Leakage Current Ratings<br />

Trip Time<br />

Test Button<br />

Leakage Trip Indicator<br />

Multiple of<br />

Rated Current<br />

20.1 - 50.0<br />

Pulse Tolerance Curve<br />

12x<br />

I r<br />

60 Hz 1/2 Cycle<br />

Inrush Pulse Tolerance<br />

4.165<br />

8.33<br />

Time Delay Curves<br />

22, 24, 26<br />

16.67<br />

t<br />

Time in<br />

Milliseconds<br />

7, 10, 15, 30, 50 & 100 milliamps. For<br />

other ratings, consult factory.<br />

300 ms Max. @ 100%, 40ms Max. @<br />

500% of must trip leakage current.<br />

On breaker face above actuator.<br />

Red LED on breaker face above<br />

actuator.<br />

Physical<br />

Number of Poles<br />

Length (included switched<br />

or unswitched neutral)<br />

Width<br />

Depth<br />

Weight: 2-pole<br />

Standard Colors<br />

Mounting<br />

Termination<br />

Environmental<br />

Operating Temperature<br />

2, 3 & 4<br />

4.2 inches ( 106.7 mm)<br />

2-pole: 3.0 inches (76.2 mm)<br />

3-pole: 3.75 inches (95.3 mm)<br />

4-pole: 4.5 inches (114.3 mm)<br />

2.5inches (63.5mm).<br />

16.0 oz. (453.6 gm)<br />

3-pole: 21.4 oz. (606.7 gm)<br />

4-pole: 26.9 oz. (762.6 gm)<br />

Housing - gray;<br />

Actuator - black, red, or white<br />

Front Panel or Standard 35mm<br />

Symmetrical DIN Rail (35 x 7.5 or<br />

35 x 15mm per DIN EN5002).<br />

Box Lug<br />

+10°C to +50°C<br />

*Manufacturer reserves the right to change product specification without prior notice.<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


18 | PD-Series – <strong>Circuit</strong> & Terminal Diagrams<br />

Notes:<br />

1 All dimensions are in inches [millimeters].<br />

2 Tolerance ±.020 [.51] unless otherwise specified.<br />

Notes:<br />

Other time delay values available, consult factory.<br />

Delay Curves 21,22,24,26: Breakers to hold 100% and must trip at 125%<br />

of rated current and greater within the time limit shown in this curve.<br />

Delay Curve 20: Breakers to hold 100% and must trip at 150% of rated<br />

current and greater within the time limit shown in this curve.<br />

All Curves: Curve data shown represents breaker response at ambient<br />

temperature of 77°F (25°C) with no preloading. Breakers are mounted in<br />

standard wall-mount position.<br />

The minimum inrush pulse tolerance handling capability is 12 times the<br />

rated current. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse.<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


PD-Series – <strong>Circuit</strong> & Terminal Diagrams | 19<br />

Notes:<br />

1 All dimensions are in inches [millimeters].<br />

2 Tolerance ±.020 [.51] unless otherwise specified.<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


20 | PD-Series – Ordering Scheme<br />

PD R – B – 24 – 650 – B – 2 A 1 – 1 – C<br />

1<br />

Series<br />

2<br />

System<br />

Voltage/Poles<br />

3<br />

<strong>Circuit</strong><br />

4<br />

Frequency<br />

& Delay<br />

5<br />

Current Rating<br />

6<br />

Equipment<br />

Leakage -<br />

Trip Current<br />

7<br />

Terminal<br />

8<br />

Actuator<br />

9<br />

Actuator<br />

Color<br />

10<br />

Mounting<br />

11<br />

Agency<br />

Approval<br />

1 SERIES<br />

PD<br />

2 SYSTEM VOLTAGE / POLES 1<br />

System Voltage<br />

A 120VAC 1Ø<br />

B 120/240 VAC 1Ø<br />

C 120/208 VAC 1Ø,<br />

120/240 VAC 1Ø<br />

D 120/208 VAC 1Ø,<br />

120/240 VAC 1Ø<br />

E 208/240 VAC 3Ø<br />

F 208/240 VAC 3Ø<br />

G 208/240 VAC 3Ø<br />

P 480Y VAC 3Ø<br />

Q 480Y VAC 3Ø<br />

R 480Y VAC 3Ø<br />

3 CIRCUIT<br />

B Series Trip (Current)<br />

4 FREQUENCY & DELAY<br />

20 50/60Hz Instantaneous<br />

22 50/60Hz Short<br />

5 CURRENT RATING (AMPERES)<br />

CODE<br />

AMPERES<br />

410 1.000<br />

512 1.250<br />

415 1.500<br />

517 1.750<br />

420 2.000<br />

522 2.250<br />

425 2.500<br />

527 2.750<br />

430 3.000<br />

435 3.500<br />

440 4.000<br />

445 4.500<br />

450 5.000<br />

455 5.500<br />

460 6.000<br />

465 6.500<br />

470 7.000<br />

475 7.500<br />

480 8.000<br />

485 8.500<br />

490 9.000<br />

495 9.500<br />

Poles<br />

One plus unswitched neutral<br />

Two<br />

Two plus unswitched neutral<br />

Two plus switched neutral<br />

Three<br />

Three plus unswitched neutral<br />

Three plus switched neutral<br />

Three<br />

Three plus unswitched neutral<br />

Three plus switched neutral<br />

24 50/60Hz Medium<br />

26 50/60Hz Long<br />

610 10.000<br />

710 10.500<br />

611 11.000<br />

711 11.500<br />

612 12.000<br />

712 12.500<br />

613 13.000<br />

614 14.000<br />

615 15.000<br />

616 16.000<br />

617 17.000<br />

618 18.000<br />

620 20.000<br />

622 22.000<br />

624 24.000<br />

625 25.000<br />

630 30.000<br />

635 35.000<br />

640 40.000<br />

650 50.000<br />

6 EQUIPMENT LEAKAGE - TRIP CURRENT (MILLIAMPS) 2<br />

B 7<br />

D 15<br />

F 50<br />

C 10<br />

E 30<br />

G 100<br />

7 TERMINAL<br />

2 Front Connected Box Lug<br />

8 ACTUATOR<br />

A Handle<br />

B Handle w/ handleguard<br />

9 ACTUATOR COLOR & LEGEND 4<br />

Acuator Color<br />

White<br />

Black<br />

Red<br />

I-O<br />

A<br />

C<br />

E<br />

ON-OFF<br />

B<br />

D<br />

F<br />

10 MOUNTING 3<br />

1 THREADED INSERT 6-32 X 0.195 INCHES<br />

2 THREADED INSERT ISO M3 X 6.5 MM<br />

11 AGENCY APPROVAL<br />

C UL Recognized & CSA Certified<br />

U TUV Certified<br />

Dual<br />

1<br />

2<br />

3<br />

Legend Color<br />

Black<br />

White<br />

White<br />

Notes:<br />

1 Units with a switched or unswitched neutral connection are the same size as a unit with<br />

an additional breaker pole (e.g. a 2-pole unit with a switched or unswitched neutral is the<br />

same physical size as a 3-pole unit.)<br />

Switched neutral poles contain the same overcurrent protection as the other poles.<br />

2 The leakage currents shown will cause the breaker to trip (must-trip current). The musthold<br />

current is 67% of the must-trip current.<br />

3 All breakers are front panel mountable using screw size shown. Breakers may also be<br />

mounted on either 35mm x 7.5mm or 35mm x 15mm symmetrical DIN rail.<br />

4 TUV certifed units must have I-O or Dual legends<br />

Time Delay Curves<br />

Instantaneous<br />

Medium<br />

Short<br />

Long<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


GFCI <strong>Circuit</strong> Breaker Selector Guide | 21<br />

PB-SERIES PC-SERIES PD-SERIES<br />

1-3 poles, 3rd pole switched neutral 1-poles(1 <strong>Circuit</strong> Breaker + 1 GFCISensor<br />

Module), 120V<br />

2-pole (2 <strong>Circuit</strong> Breakers + 1 GFCI Sensor<br />

Module), 120/240V or 120V with Neutral<br />

Break.<br />

3-pole 120/240V with Neutral Break (Sensor<br />

module has 2 pole width)<br />

1-3 poles, with switched or<br />

unswitched neutral options<br />

NUMBER OF POLES<br />

Handle, Rocker, Flat Rocker actuators Handle, Rocker, Flat Rocker, Push-to-reset Handle, with handleguard option ACTUATOR STYLE<br />

30mA & 6mA 30mA & 6mA 7-100 milliamps LEAKAGE CURRENT<br />

TRIP LEVEL<br />

For 30mA leakage trip:<br />

≤ 22.2mA, shall not trip<br />

30mA, shall trip within .10 seconds,<br />

<strong>com</strong>plying with UL-1053<br />

& ABYC E11. For 6mA leakage<br />

trip: ≤25ms, <strong>com</strong>plying with UL-943.<br />

For 30mA leakage trip:<br />

≤ 22.2mA, shall not trip<br />

30mA, shall trip within .10 seconds,<br />

<strong>com</strong>plying with UL-1053<br />

& ABYC E11. For 6mA leakage<br />

trip: ≤25ms, <strong>com</strong>plying with UL-943.<br />

300 ms Max. @ 100%, 40ms<br />

Max. @ 500% of must trip leakage<br />

current<br />

LEAKAGE CURRENT<br />

TRIP TIME<br />

0.10 - 30 amps @ 120/240VAC 0.10 - 50 amps @ 120/240VAC - 240VAC 120VAC, Single Phase<br />

120/208VAC, Single Phase<br />

120/240VAC, Single Phase<br />

208/240VAC, Three Phase<br />

480Y/277VAC, Three Phase<br />

5,000 amps 5,000 amps 5,000A @ 120/208 VAC;<br />

120/240VAC, Single phase<br />

2,000A @ 208/240, Three phase<br />

2,000A @ 480Y/277VAC,<br />

Three phase<br />

MAXIMUM CURRENT &<br />

VOLTAGE RATINGS<br />

MAXIMUM<br />

INTERRUPTING<br />

CAPACITY<br />

Series Trip Series Trip Series Trip AVAILABLE<br />

CIRCUITS<br />

.250 Quick Connect Tabs<br />

8-32, 10-32, M4,M5 screw with upturned lugs<br />

8-32, 10-32, M4,M5 screw, Bus Type<br />

10-32 Threaded Stud Front Connected Box Lug<br />

w/ pressure plate<br />

TERMINAL<br />

OPTIONS<br />

Front Panel Front Panel Front Mounted or Din Rail<br />

Mounted<br />

MOUNTING METHOD<br />

-35° C to +65° C -35° C to +65° C -10°C to 60°C OPERATING<br />

TEMPERATURE<br />

UL489, CSA, UL1077, UL1500 UL943, UL1053, UL1500 UL Recognized, CSA, TUV AGENCY<br />

APPROVALS<br />

DIMENSIONS<br />

3.800<br />

[96.52]<br />

0.350<br />

[8.89]<br />

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>


Worldwide Headquarters<br />

Carling Technologies, Inc.<br />

60 Johnson Avenue • Plainville, CT 060621177<br />

Phone: (860) 7939281 • Fax: (860) 7939231<br />

Email: sales<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong><br />

Asia-Pacific Headquarters<br />

Carling Technologies, Asia-Pacific Ltd.,<br />

Kowloon, Hong Kong<br />

nt 8227372277 • Fax: nt 8227369332<br />

Email: sales@<strong>carlingtech</strong>.<strong>com</strong>.hk<br />

Europe/Middle East/Africa Headquarters<br />

Carling Technologies, Ltd.,<br />

Devon, England 06062-1177<br />

nt 13923622 • Fax: nt 13923677<br />

Email: ltd.sales@<strong>carlingtech</strong>.<strong>com</strong><br />

GFCI-CAT_05_12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!