ULTima<br />

The ULTimate in<br />

Gel Documentation<br />

and Imaging


The ULTima imaging platform is the fastest, most straightforward and<br />

readily upgradable unit available, incorporating the latest advances in<br />

electronics and optics. The ULTima can economically handle everything from<br />

the most routine to the most demanding applications in proteomics and<br />

genomics, which have until now required expensive laser scanning systems.<br />

Full line of upgradable instruments (ULTima10si, 16si, 16si Plus and Pro)<br />

allows you to upgrade to higher specifications as research needs change.<br />

High resolution gel documentation and<br />

imaging with exceptional sensitivity and<br />

ease of use.<br />

Patented image positioning tool aligns the sample from the computer<br />

and permits imaging of a selected part of a large gel or blot.<br />

Patented slant correction tool corrects the orientation of the sample from<br />

the computer.<br />

Mega-pixel CCD cameras with 10 bit and 16 bit arrays provide very high<br />

resolution images.<br />

Large 21 x 26 cm imaging area allows documentation of large samples<br />

like 2D gels.<br />

Superior dynamic range with the 16si and Pro models with 65536 gray<br />

levels allows precise quantification of samples and shortens exposure<br />

times for chemiluminescent images.<br />

Compact design saves precious lab space.<br />

ULTima Pro permits true multi-fluorophore imaging when used with the<br />

Optix illumination module.<br />

Image addition tools permit kinetic studies.<br />

All models of ULTima permit easy access to robots.<br />

All models of the ULTima permit GLP validation.<br />

All models can be upgraded as research needs grow.<br />

ULTima<br />

Imaging<br />

Platform<br />

Broadest Range<br />

of Applications.<br />

Fluorescent and Calorimetric Imaging<br />

with a wide array of dyes.<br />

Absorbance/Visible Imaging.<br />

Culture and Microplate Based Assays.<br />

Large Sized 1D and 2D Gels for<br />

proteomics applications.<br />

Chemiluminescent imaging on ULTima<br />

Pro cooled CCD system.<br />

Multi-fluorophore imaging with ULTima<br />

Pro and Optix illumination module.


Unique Patented Image Positioning and Slant Correction<br />

Positioning tools on ULTima AQ software help position gels or other samples<br />

from the computer. The positioning is easy, accurate and fast with minimum<br />

handling of fragile gels or other samples. Every user of an imaging system has<br />

experienced the problem that the gel is never in the right place initially. With<br />

most commercially available systems the user has to open the drawer or door<br />

and manually handle the gel for the best visualization. The ULTima, however,<br />

is the only imaging system with patented optics for image positioning without<br />

loss of optical resolution. This also ensures that lens adjustments are not<br />

required. The image is positioned with the positioning keys without having to<br />

open the cabinet or adjust a fragile gel.<br />

Slant correction tools permit optical rotation<br />

of the sample for best ‘straight’ visualization<br />

without touching the gel. Slant correction<br />

is a unique feature that allows the user to<br />

turn the image optically ± 5°. In this way<br />

the sample can be positioned so the analysis<br />

software is better able to perform lane<br />

detection.<br />

Flatfielding<br />

ULTima imaging systems allow<br />

accurate quantitative measurements<br />

of samples with a unique feature<br />

called flatfielding. Flatfielding is done<br />

in two easy steps after selecting the<br />

flatfielding option on the ULTima AQ<br />

software. Flatfielding removes<br />

artifacts resulting from small<br />

variations in the CCD and uneven<br />

background presenting a true image<br />

of sample intensities. The Orange<br />

conversion plate is used to create a<br />

flatfield image and the ULTima AQ<br />

software uses this flatfield image to<br />

“clean up” any variations to present<br />

raw image data that is highly<br />

accurate.<br />

Image Addition<br />

ULTima imaging systems allow users<br />

to simultaneously capture multiple<br />

images of the same sample at a set<br />

interval with a unique feature called<br />

Image Addition. The user can set the<br />

number of images to be ‘added’ and<br />

the time interval between<br />

acquisitions. This feature allows the<br />

ULTima to be used in kinetic studies.<br />

If the image addition is used in<br />

combination with the Auto-Save<br />

function, all the individual images will<br />

be stored. The added result should be<br />

stored manually.<br />

Templates<br />

Templates allow the user to define the<br />

settings for image acquisition,<br />

including the excitation and emission<br />

filters. The parameters are stored per<br />

specific application.<br />

Orange Conversion Plate<br />

The optional orange conversion plate<br />

allows transillumation of visible dyes<br />

like Coomassie and silver stain on a<br />

UV transilluminator. The conversion<br />

plate is also required for flatfielding<br />

the image.


How to choose<br />

your ULTima?<br />

There are four systems plus the optional Optix illumination module. All models<br />

can be upgraded to higher specified versions giving you the flexibility to<br />

purchase the model that meets your needs and budget today and upgrade it<br />

as your needs increase. All models come with ULTima AQ control and image<br />

acquisition software and ethidium bromide emission filter.<br />

UV Transilluminator Orange Conversion Plate


ULTima 10si & 16si<br />

Use ULTima 10si for basic documentation purposes. With<br />

ULTima 16si your measurements are more sensitive and<br />

allow more accurate quantification. Both models can be<br />

used for imaging ethidium bromide stained DNA agarose<br />

gels, Coomassie stained gels, SYBR Green stained gels,<br />

SYPRO Ruby stained gels, film archiving and petri dishes.<br />

General purpose gel documentation system.<br />

Fluorescence ready.<br />

ULTima 10si has a 10 bit CCD camera (1024 gray<br />

levels) and ULTima 16si has a 16 bit CCD camera<br />

(65536 gray levels).<br />

Image positioning / Slant correction.<br />

Electronic optical zoom (6X).<br />

White light top illumination.<br />

ULTima 16si Plus<br />

High dynamic range general purpose gel<br />

documentation system.<br />

ULTima 16si Plus has a 16 bit CCD camera<br />

(65536 gray levels).<br />

Electronic optical iris and electronic optical focus.<br />

ULTima 16si Plus is equipped for multi-plexed<br />

multi-fluorophore applications.<br />

Image positioning / Slant correction.<br />

Electronic optical zoom (6X).<br />

White light top illumination.<br />

ULTima Pro<br />

Designed with innovative 2-stage Peltier cooling of the image<br />

sensor. Rather than attempt to cool the entire CCD chip to<br />

a very low temperature, the ULTima Pro cools only the areas<br />

of the chip where cooling is essential to achieve low noise<br />

levels at long measurement times. This substantially<br />

lengthens the lifetime of the CCD chip and the camera<br />

system. As with ULTima 16si Plus, the ULTima Pro is equipped<br />

with an additional computer-controlled focus and iris control.<br />

The ULTima Pro comes with a small external power supply<br />

that drives the Peltier cooling system.<br />

High sensitivity chemiluminescence imaging system.<br />

ULTima Pro has the top of the line 16 bit temperature<br />

controlled cooled CCD camera (65536 gray levels).<br />

Electronic optical iris and electronic optical focus.<br />

Image positioning / Slant correction.<br />

Electronic optical zoom (6X).<br />

White light top illumination.<br />

Technical Specifications<br />

Model<br />

Resolution (pixel)<br />

Resolution (sec.)<br />

Image Sensor Cooling<br />

Camera Bit Depth<br />

Electronic Optical Zoom<br />

Electronic Iris Control<br />

Electronic Focus Control<br />

Image Position System<br />

Slant Control<br />

Emission Filter Positions<br />

White Light Top Illumination<br />

Automatic Door Lock<br />

Contrast Control<br />

Brightness Control<br />

Flat Fielding<br />

Saturation Indication<br />

Image Addition (x)<br />

Addition Interval (min.)<br />

10si<br />

Filetype: tiff (16 bit), Tif (8 bit), bmp, jpg, gif<br />

16si<br />

16si Plus Pro<br />

Mains: 110/230 Voltage AC automatic detection 50-60 Hz 180 Watt max. Installation Cat. II<br />

Outer Dimensions (W x H x D): 510 x 380 x 500 mm<br />

Weight: 41 kg.<br />

1312 x 1032<br />

0.001 - 10<br />

No<br />

10<br />

6 x<br />

No<br />

No<br />

Yes<br />

± 5°<br />

1<br />

(5 optional)<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

No<br />

No<br />

1392 x 1040<br />

0.001 - 10<br />

IMPORTANT: For installing and using the ULTima and ULTima AQ software the<br />

following computer minimum specifications are required:<br />

Computer working under Windows 2000, Windows XP-Home (SP1) or XP-Professional<br />

(SP1) minimum 256 Mb RAM, minimum screen resolution 1024 x 768, one free USB 2.0<br />

port (800 mA or 500 mA) one free RS-232C port (9 pin), pointing device, 1 Gb free harddisk<br />

space.<br />

No<br />

16<br />

6 x<br />

No<br />

No<br />

Yes<br />

± 5°<br />

1<br />

(5 optional)<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

1 - 25<br />

0 - 20<br />

1392 x 1040<br />

0.001 - 10<br />

No<br />

16<br />

6 x<br />

Yes<br />

Yes<br />

Yes<br />

± 5°<br />

1<br />

(5 optional)<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

1 - 25<br />

0 - 20<br />

1392 x 1040<br />

0.001 - 3000<br />

Yes, 6 arrays<br />

16<br />

6 x<br />

Yes<br />

Yes<br />

Yes<br />

± 5°<br />

1<br />

(5 optional)<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

1 - 25<br />

0 - 20


Optix<br />

Illumination<br />

Module<br />

The Optix module is a patented epiillumination<br />

option for ULTima Pro; for<br />

the excitation of fluorophores within<br />

the VIS/NIR range. When Optix is used<br />

for ethidium bromide stained gels, it<br />

offers the following advantages:<br />

DNA remains intact for applications<br />

downstream.<br />

Lower background means higher<br />

detection limits.<br />

Selection of excitation wavelength is<br />

fully computer controlled and, in<br />

combination with the automatic<br />

emission filter changer, true multi<br />

fluorophore capability is achieved.<br />

Multiple images with different<br />

excitation/emission filter sets allow<br />

the detection of multiple<br />

fluorophores within the same<br />

sample. The Optix can<br />

accommodate a maximum of five<br />

different excitation filter sets. The<br />

Optix module can be added to all<br />

models of the ULTima line.<br />

Applications that are possible with<br />

the addition of the Optix module<br />

include: CyDye imaging, array<br />

detection, in vivo GFP detection and<br />

GFP tissue and organ screening.<br />

Pseudo-color image<br />

of macro array,<br />

labeled with Cy5.5<br />

GFP detection<br />

in leaves.<br />

TotalLab <br />

Analysis<br />

Software<br />

Select the software that best meets your needs by your area of work below:<br />

Molecular Weight Calibration<br />

The TL 100 and TL 120 versions both enable precise molecular weight determination of<br />

band material from a variety of 1D gels. TL 120 contains tools which allow increased<br />

control over calibration for particularly distorted 1D gel images.<br />

Quantitation and Normalization of Band Material<br />

The TL 100 and TL 120 software solutions both contain a complete range of tools to<br />

quantify band material and for the calculation of normalized band volumes. For in-depth<br />

quantitative studies, the advanced features in TL 120 offer a higher degree of flexibility<br />

and facilitate accurate quantitation of bands on more problematic 1D gel images.<br />

Lane Relationship Studies<br />

The TL 120 software has a powerful band matching facility which is flexible yet easy to<br />

use. There are tools available to visualize the results of matching and identify similarities<br />

within a single gel. When you have performed intra gel matching, lanes can be classified<br />

and identified.<br />

TL 100<br />

Entry level software<br />

for fast, consistent<br />

analysis.<br />

TL 120<br />

For an in-depth and<br />

accurate automatic<br />

analysis of 1D gels<br />

and band pattern<br />

matching studies.<br />

The TotalLab analysis software provides a complete set of tools for<br />

fast, accurate and easy analysis of images from the ULTima for<br />

molecular weight determination, sample quantitation, arrays, dot<br />

blot/slot blot analysis and colony counting.<br />

Summary of features in the<br />

TotalLab range: TL 100 TL 120<br />

Automatic detection of lanes and bands<br />

Automatic background subtraction<br />

Lane templates<br />

Image manipulation tools<br />

Analysis protocols for batch processing<br />

Molecular weight calibration<br />

Quantity calibration<br />

Normalization<br />

Profile deconvolution<br />

Rf calibration<br />

Band picking<br />

Band pattern matching - single gel<br />

Dendrogram - single gel<br />

Reports<br />

Array, dot / slot blot analysis<br />

Colony counting<br />

A toolbox for general image analysis


TL 100 Control Center<br />

Analysis protocols enable consistent processing of<br />

multiple gels in TL 120.<br />

ID Gel Image analyzed by TL 100 Calibration of a 1D gel using multiple molecular marker lanes in TL 120.


953 Indiana Street<br />

San Francisco, CA 94107 USA<br />

Hoefer is a Harvard Bioscience company.<br />

www.hoeferinc.com<br />

Toll Free: 1-800-227-4750<br />

Local Phone: 1-415-282-2307<br />

Customer Service:<br />

Select 1 from the main menu<br />

Technical Support:<br />

Select 2 from the main menu.<br />

Fax: 1-415-920-4494 or 1-415-821-0239<br />

Online Ordering: www.hoeferinc.com<br />

Email: support@hoeferinc.com<br />

For inquiries please contact your local<br />

Hoefer representative below:<br />

Trademarks:<br />

ULTima, Optix and Hoefer are trademarks of Hoefer, <strong>Inc</strong>.<br />

TotalLab is a trademark of Non Linear Dynamics.<br />

Windows and Windows XP are trademarks of Microsoft Corp.<br />

SYBR Green is a trademark of Molecular Probes.<br />

Cy3 and Cy5 are trademarks of GE Healthcare.<br />

Coomassie is a trademark of ICI.<br />

©2006 Hoefer, <strong>Inc</strong>. - All rights reserved.<br />

Printed in the USA.<br />

Ordering the ULTima<br />

Basic System<br />

The basic package includes the ULTima model of your choice, ULTima AQ communication suite<br />

and Ethidium Bromide orange filter. ULTima 16si Plus and Pro models come with a filter selector.<br />

ULTima Pro comes with a power supply for the cooling Peltier.<br />

ULT101 ULTima 10si imaging unit<br />

ULT161 ULTima 16si imaging unit<br />

ULT161F ULTima 16si Plus imaging unit<br />

ULT161C ULTima Pro cooled CCD imaging unit<br />

Complete System<br />

Use part numbers below to order a complete ULTima package.<br />

The complete system package includes ULTima model of your choice, ULTima AQ communication<br />

suite and Ethidium Bromide orange filter. UV-26 transilluminator and TL100 Total Lab analysis<br />

software. ULTima 16si Plus and Pro models come with a filter selector. ULTima Pro comes with a<br />

power supply for the cooling Peltier.<br />

ULT10 ULTima 10si imaging system<br />

ULT16 ULTima 16si imaging system<br />

ULT16F ULTima 16si Plus imaging system<br />

ULT16C ULTima Pro cooled CCD imaging system<br />

Transilluminator and Analysis Software Sold Separately:<br />

UV26 UV-26 Transilluminator with 21 x 26 cm imaging area<br />

ULT162 TL100 TotalLab analysis software Single user license<br />

ULT163 TL120 TotalLab analysis software Single user license<br />

ULT215 TL100 TotalLab image analysis Network version includes 3 user license<br />

ULT216 TL100 TotalLab image analysis Network single user license<br />

ULT217 TL100 TotalLab image analysis additional single user license for standalone installations<br />

Optional Accessories:<br />

ULT164 Optix illumination module (only for ULTima Pro)<br />

ULT165 Orange conversion plate<br />

ULT220 Emission filter changer for 5 filters ( for ULTima 16si )<br />

ULT312 UV transillumination cassette 312 nm. 21 x 26 cm<br />

ULT306 UV Top light source basic holder<br />

ULT365 UV Top light extension 365 nm<br />

ULT302 UV Top light extension 302 nm.<br />

ULT256 UV Top light extension 256 nm.<br />

ULT201 Emission filter 480-550 (e.g. EBFP, ECF) for mounting on filterchanger<br />

ULT202 Emission filter 480-550 (e.g. EBFP, ECF) for mounting on lens<br />

ULT203 Emission filter 515-565 (e.g. SYBR Green, EGFP, EYFP) for mounting on filterchanger<br />

ULT204 Emission filter 515-565 (e.g. SYBR Green, EGFP, EYFP) for mounting on lens<br />

ULT205 Emission filter 570-650 (e.g. Eth. Bromide filter, Cy3) for mounting on filterchanger<br />

ULT206 Emission filter 570-650 (e.g. Eth. Bromide filter, Cy3) for mounting on lens<br />

ULT207 Emission filter 665-730 (e.g. Cy5) for mounting in filterchanger<br />

ULT208 Emission filter 665-730 (e.g. Cy5) for mounting on lens<br />

ULT210 Black Sample tray (Luminescent / Optix)<br />

ULT211 Excitation filter set for Optix, 450 nm<br />

ULT212 Excitation filter set for Optix, 500 nm<br />

ULT213 Excitation filter set for Optix, 555 nm ( standard)<br />

ULT214 Excitation filter set for Optix, 650 nm<br />

ULT220 USB to RS232 serial adapter for computers without a serial port