ModelNomenclatureAir H<strong>an</strong>dler -<strong>Residential</strong>Air H<strong>an</strong>dler/Electric FurnaceHeatersFurnaces15 - DigitAir H<strong>an</strong>dler -CommercialFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.TOC-5Effective 1/1/06


ModelNomenclatureGas FurnacesHeat Pump/Cooling CoilsOil FurnacesOil FurnaceAccessoriesEffective 1/1/06TOC-6For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


ModelNomenclatureHumidifiersHumidifierControlsHumidifierAccessoriesEnergyRecoveryVentilator(ERV)Effective 1/1/06TOC-8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


ModelNomenclaturePackage Units15 - DigitPackage UnitsFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.TOC-9Effective 1/1/06


ModelNomenclaturePrecedentUnitsEffective 1/1/06TOC-10For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


ModelNomenclaturePrecedent13 SEER UnitsFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.TOC-11Effective 1/1/06


ModelNomenclatureComfortControlsDuctlessOutdoor UnitsIntegrated ZoneSystemDuctlessAir ConditionersEffective 1/1/06TOC-12For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


ModelNomenclaturePackagedTerminalsIndoor GasHeating UnitsFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.TOC-13Effective 1/1/06


ModelNomenclatureHorizontalBlower AssemblyModel SUnit HeaterEffective 1/1/06TOC-14For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


ModelNomenclatureModel PUnit HeaterElectric HeatersModel UHECElectric WallMountedUnitHeatersModel UHWAFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.TOC-15Effective 1/1/06


ModelNomenclatureElectric Hose DownUnit HeaterModel UHRAElectric CeilingMounted HeatersModel UHCAElectric ExplosionProof Unit HeatersModel UHXAElectricArchitecturalWall HeatersModel UHAAEffective 1/1/06TOC-16For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System CoolingSingle Phase – 1½ through 5 TonsTable SC-1-A — XL19i Split System Cooling — Single PhaseNom. Cap. Uncrated Shipping Line SizeModel Power Cooling Metering Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Device H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TTZ9030B1000A 200-230/1/60 30,000 TXV-NB 50 37 34 439 72 18 30 7/82TTZ9036B1000A 200-230/1/60 36,000 TXV-NB 50 37 34 436 74 22 35 7/82TTZ9048B1000A 200-230/1/60 48,000 TXV-NB 50 37 34 444 74 25 40 1 1 /83/83/83/8XL19i2TTZ9060B1000A 200-230/1/60 60,000 TXV-NB 50 37 34 448 73 37 60 1 1 /8Note: Because of limited capabilities, please refer to product data for approved combinations.Table SC-1-B — XL16i Split System Cooling — Single PhaseNom. Cap. Uncrated Shipping Line SizeModel Power Cooling Metering Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Device H W D (lbs.) Rating MCA* Fuse* Gas Liq.4TTX6024B1000A 230/1/60 24,000 TXV-NB 44 33 30 254 73 12 20 5/8 5/164TTX6036B1000A 230/1/60 36,000 TXV-NB 42 37 34 288 72 24 40 3/4 3/84TTX6048B1000A 230/1/60 48,000 TXV-NB 50 37 34 312 74 29 50 7/8 3/84TTX6060B1000A 230/1/60 60,000 TXV-NB 50 37 34 356 74 35 60 7/8 3/83/8XL16iXL15iXL14iTable SC-1-C — XL15i Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TTX5024A1000A 208/230/1/60 24,000 TXV-NB 46 37 34 283 72 14 20 3/4 5/162TTX5030A1000A 208/230/1/60 30,000 TXV-NB 46 37 34 284 74 16 25 3/4 5/162TTX5036A1000A 208/230/1/60 36,000 TXV-NB 50 37 34 300 72 18 30 7/8 3/82TTX5042A1000A 208/230/1/60 42,000 TXV-NB 50 37 34 307 73 23 35 7/8 3/82TTX5048A1000A 208/230/1/60 48,000 TXV-NB 50 37 34 337 72 26 40 1 1 /8 3/8Table SC-1-D — XL14i Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TTX4018B1000A 200-230/1/60 18,000 TXV-NB 40 33 30 220 73 10 15 5/8 1/42TTX4024B1000A 200-230/1/60 24,000 TXV-NB 40 33 30 236 73 11 15 3/4 5/162TTX4030B1000A 208-230/1/60 30,000 TXV-NB 40 33 30 244 74 18 30 3/4 5/162TTX4036B1000A 208-230/1/60 36,000 TXV-NB 44 33 30 248 72 20 30 7/8 3/82TTX4042B1000A 208-230/1/60 42,000 TXV-NB 46 37 34 289 75 24 40 7/8 3/82TTX4048B1000A 208-230/1/60 48,000 TXV-NB 50 37 34 306 75 28 45 1 1 /8 3/82TTX4060B1000A 208-230/1/60 60,000 TXV-NB 50 37 34 354 75 34 50 1 1 /8 3/8Table SC-1-E — XL14i Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.XL14i4TTX4018B1000A 200-230/1/60 18,000 TXV-NB 40 33 30 236 74 10 15 1/24TTX4024B1000A 200-230/1/60 24,000 TXV-NB 40 33 30 239 74 13 20 5/84TTX4030B1000A 208-230/1/60 30,000 TXV-NB 40 33 30 242 71 20 30 3/44TTX4036B1000A 208-230/1/60 36,000 TXV-NB 44 33 30 255 71 21 35 3/44TTX4042B1000A 208-230/1/60 42,000 TXV-NB 46 37 34 297 74 25 40 3/44TTX4048B1000A 208-230/1/60 48,000 TXV-NB 50 37 34 310 74 27 45 7/84TTX4060C1000A 208-230/1/60 60,000 TXV-NB 50 37 34 360 74 35 60 7/8* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accord<strong>an</strong>ce with ARI St<strong>an</strong>dard 270, section 5.3.6.1/45/165/163/83/83/83/8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.SC-1Effective 1/1/06


Split System CoolingSingle Phase – 1½ through 5 TonsXL19i XL16i XL15i XL14i XL 14iTable SC-2-A — Features (2TTZ9) (4TTX6) (2TTX5) (2TTX4) (4TTX4)• SEER’s up to .......................................................................................................... 19.50 17.15 16.25 15.00 15.00• Climatuff compressor ........................................................................................ 2 1 - staged ✔ ✔ ✔• Comfort”R” mode approved ............................................................................. ✔ ✔ ✔ ✔ ✔• DuraTuff base, fast complete drain, weatherproof ............................................. ✔ ✔ ✔ ✔ ✔• Quick-Sess cabinet, service access & .............................................................. ✔ ✔ ✔ ✔ ✔refriger<strong>an</strong>t connections with full coil protection• Spine Fin coil ..................................................................................................... ✔ ✔ ✔ ✔ ✔• Weatherguard II top .......................................................................................... ✔ ✔ ✔ ✔ ✔• Compressor sound enclosure ................................................................................ ✔ ✔ ✔ ✔ ✔• Compressor sump heat - factory installed .............................................................. 2½-5 5 2-4 1½-2 & 3½-5 1½-2• Factory supplied charge ......................................................................................... R-22 R-410A R-22 R-22 R-410A• Glossy corrosion resist<strong>an</strong>t finish ............................................................................ ✔ ✔ ✔ ✔ ✔• High pressure switch .............................................................................................. — ✔ — — ✔• Internal high / low pressure & temperature protection ............................................ ✔ ✔ ✔ ✔ ✔• Liquid line filter drier - factory installed ................................................................... ✔ ✔ ✔ ✔ ✔• Quick start kit-factory installed ............................................................................... 2½-5 5 — 1½-2 & 5 1½-2 & 5• Seacoast shield - factory installed .......................................................................... ✔ ✔ ✔ ✔ ✔• Tarpaulin gray cabinet ............................................................................................ ✔ ✔ ✔ ✔ ✔• 10-year limited warr<strong>an</strong>ty on compressor, ............................................................... ✔ ✔ ✔ ✔ ✔outdoor coil & parts (<strong>Residential</strong>)• Extended warr<strong>an</strong>ties available ............................................................................ ✔ ✔ ✔ ✔ ✔Table SC-2-B — Optional AccessoriesAY28X079 ..................... Evaporator defrost control kit ............................................. ✔ ✔ ✔ ✔ ✔BAYCCHT301 ............... Cr<strong>an</strong>k Case Heater Kit (Scroll Compressors) ................... — 2-4 — 2½-3 2½-5BAYECMT001 ............... Extreme Condition Mounting Kit ........................................ ✔ ✔ ✔ ✔ ✔BAYISLT101 .................. Rubber Isolators ................................................................. ✔ ✔ ✔ ✔ ✔BAYKSKT260 ............... Quick start kit (2 1 /2 - 4 ton) (Scroll Compressors) ............. — 2-4 2-4 2½-4 2½-4BAYLEGS002 ............... Snow Legs - Base <strong>an</strong>d Cap 6" High (Black) ...................... ✔ ✔ ✔ ✔ ✔BAYLEGS003 ............... 4" Extension (Black) ........................................................... ✔ ✔ ✔ ✔ ✔TAYASCT501A12 ...... Anti-Short Cycle Timer ....................................................... ✔ ✔ ✔ ✔ ✔Comfort Controls — See Comfort Controls/Zone Sensors Section1 Not for use with programmable thermostats.2 Activated on Power Off.Effective 1/1/06SC-2For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System CoolingSingle Phase – 1½ through 5 TonsTable SC-3-A — XR14 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.XR142TTR4018A1000A 200-230/1/60 18,000 TXV-NB 33 33 30 206 76 10 15 5/82TTR4024A1000A 200-230/1/60 24,000 TXV-NB 33 33 30 225 76 11 15 3/42TTR4030A1000A 208-230/1/60 30,000 TXV-NB 37 33 30 232 75 18 30 3/42TTR4036A1000A 208-230/1/60 36,000 TXV-NB 37 33 30 236 76 20 30 7/82TTR4042A1000A 208-230/1/60 42,000 TXV-NB 37 37 30 269 78 24 40 7/82TTR4048A1000A 208-230/1/60 48,000 TXV-NB 41 37 34 285 77 28 45 1 1 /82TTR4060A1000A 208-230/1/60 60,000 TXV-NB 41 37 34 336 79 34 50 1 1 /81/45/165/163/83/83/83/8Table SC-3-B — XR14 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.XR144TTR4018A1000A 200-230/1/60 18,000 TXV-NB 33 33 30 222 75 10 15 1/24TTR4024A1000A 200-230/1/60 24,000 TXV-NB 33 33 30 225 76 13 20 5/84TTR4030A1000A 208-230/1/60 30,000 TXV-NB 33 33 30 228 74 20 30 3/44TTR4036A1000A 208-230/1/60 36,000 TXV-NB 37 33 30 240 74 21 35 3/44TTR4042A1000A 208-230/1/60 42,000 TXV-NB 37 37 34 273 76 25 40 3/44TTR4048A1000A 208-230/1/60 48,000 TXV-NB 41 37 34 285 76 27 45 7/84TTR4060B1000A 208-230/1/60 60,000 TXV-NB 41 37 34 335 77 35 60 7/81/45/165/163/83/83/83/8Table SC-3-C — XR13 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.XR132TTR3018A1000A 200-230/1/60 18,000 TXV-NB 26 29 26 180 74 8 15 5/82TTR3024A1000A 200-230/1/60 24,000 TXV-NB 33 29 26 195 76 12 20 3/42TTR3030A1000A 200-230/1/60 30,000 TXV-NB 33 33 30 226 74 13 20 3/42TTR3036A1000A 208-230/1/60 36,000 TXV-NB 33 33 30 221 75 18 30 7/82TTR3042A1000A 200-230/1/60 42,000 TXV-NB 33 37 34 284 77 21 35 7/82TTR3048A1000A 200-230/1/60 48,000 TXV-NB 41 37 34 309 76 25 40 1 1 /82TTR3060A1000A 208-230/1/60 60,000 TXV-NB 41 37 34 305 76 32 50 1 1 /8* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accord<strong>an</strong>ce with ARI St<strong>an</strong>dard 270, section 5.3.6.1/45/165/163/83/83/83/8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.SC-3Effective 1/1/06


Split System CoolingSingle Phase – 1½ through 5 TonsXR 14 XR 14 XR 13Table SC-4-A — Features (2TTR4) (4TTR4) (2TTR3)• SEER’s up to ............................................................................................................................................. 14.00 14.00 14.00• Climatuff compressor ........................................................................................................................... ✔ ✔ ✔• Comfort”R” mode approved ................................................................................................................ ✔ ✔ ✔• DuraTuff base, fast complete drain, weatherproof ................................................................................ ✔ ✔ ✔• Quick-Sess cabinet, service access & refriger<strong>an</strong>t connections with full coil protection ........................ ✔ ✔ ✔• Spine Fin coil ........................................................................................................................................ ✔ ✔ ✔• Compressor sound enclosure ................................................................................................................... ✔ ✔ ✔• Compressor sump heat - factory installed ................................................................................................. 1½-2,3½-5 1½-2 5• Factory supplied charge ............................................................................................................................ R-22 R-410A R-22• Glossy corrosion resist<strong>an</strong>t finish ............................................................................................................... ✔ ✔ ✔• High pressure switch ................................................................................................................................. — ✔ —• Internal high / low pressure & temperature protection ............................................................................... ✔ ✔ ✔• Liquid line filter drier - factory installed ...................................................................................................... ✔ ✔ ✔• Quick start kit - factory installed ................................................................................................................ 1½-2,5 1½-2,5 1½-2½,3½-5• Tarpaulin gray cabinet ............................................................................................................................... ✔ ✔ ✔• 10-year limited warr<strong>an</strong>ty on compressor, outdoor coil & 5 years on parts (<strong>Residential</strong>) ............................ ✔ ✔ ✔• Extended warr<strong>an</strong>ties available ............................................................................................................... ✔ ✔ ✔Table SC-4-B — Optional AccessoriesAY28X079 .............. Evap. Defrost Control Kit .............................................................................................. ✔ ✔ ✔BAYCCHT300 ........ Cr<strong>an</strong>kcase Heater Kit (Reciprocating Compressors) .................................................... — — 1½-2½,3½-4BAYCCHT301 ........ Cr<strong>an</strong>kcase Heater Kit (Scroll Compressors) ................................................................. 2½-3 2½-5 3BAYECMT001 ........ Extreme Condition Mounting Kit ................................................................................... ✔ ✔ ✔BAYISLT101 .......... Rubber Isolators ........................................................................................................... ✔ ✔ ✔BAYKSKT260 ........ Start Kit (Scroll Compressors) ...................................................................................... 2½-4 2½-4 3BAYLEGS002 ........ Snow Legs - Base <strong>an</strong>d Cap 6" High (Black) ................................................................. ✔ ✔ ✔BAYLEGS003 ........ 4" Extension (Black) ..................................................................................................... ✔ ✔ ✔BAYLOAM103 ........ Low Ambient Kit ........................................................................................................... ✔ — ✔BAYSEAC001 ........ Seacoast Kit ................................................................................................................. ✔ ✔ ✔TAYASCT501A12 . Anti-Short Cycle Timer ................................................................................................. ✔ ✔ ✔Comfort Controls — See Comfort Controls/Zone Sensors Section1 Not for use with programmable thermostats2 Activated on Power Off.Effective 1/1/06SC-4For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System CoolingSingle Phase – 1½ through 5 TonsTable SC-5-A — XR12 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.4TTR2018A1000A 200-230/1/60 18,000 .049 33 33 30 215 77 10 15 1/21/4XR124TTR2024A1000A 200-230/1/60 24,000 .053 33 33 30 219 78 13 20PHASED OUT5/84TTR2030A1000A 208-230/1/60 30,000 .059 33 33 30 218 74 20 30 3/44TTR2036A1000A 208-230/1/60 36,000 .065 33 33 30 231 77 21 35 3/44TTR2042A1000A 208-230/1/60 42,000 .071 37 33 30 243 78 25 40 3/44TTR2048A1000A 208-230/1/60 48,000 .077 41 33 30 260 79 31 50 7/84TTR2060A1000A 208-230/1/60 60,000 1 33 37 34 283 81 36 60 7/85/165/163/83/83/83/8Table SC-5-B — XR12 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TTR2018A1000A 200-230/1/60 18,000 .051 26 29 26 171 79 10 15 5/82TTR2024A1000A 200-230/1/60 24,000 .057 29 29 26 187 78 11 15 3/41/45/16XR122TTR2030A1000APHASED208-230/1/60 30,000 .065 29 29 26 180OUT79 18 30 3/42TTR2036A1000A 208-230/1/60 36,000 .071 33 29 26 195 79 21 35 7/82TTR2042B1000A 208-230/1/60 42,000 .077 33 33 30 228 79 23 40 7/82TTR2048A1000A 208-230/1/60 48,000 .086 37 33 30 247 78 26 45 1 1 /82TTR2060B1000A 208-230/1/60 60,000 1 41 37 34 270 79 33 50 1 1 /85/163/83/83/83/8Table SC-5-C — XR11 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TTR1018A1000A 200-230/1/60 18,000 .049 26 20 19 129 82 10 15 5/82TTR1024A1000A 200-230/1/60 24,000 .057 26 20 19 141 81 13 20 3/41/45/16XR112TTR1030A1000APHASED200-230/1/60 30,000 .065 26 29 26 168OUT79 17 30 3/42TTR1036A1000A 200-230/1/60 36,000 .073 26 29 26 177 77 22 35 7/82TTR1042A1000A 200-230/1/60 42,000 .075 29 29 26 212 79 24 40 7/82TTR1048A1000A 200-230/1/60 48,000 .083 29 29 26 219 79 29 50 1 1 /82TTR1060A1000A 200-230/1/60 60,000 1 37 33 30 269 79 36 60 1 1 /81 Indoor Metering device TXV only.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accord<strong>an</strong>ce with ARI St<strong>an</strong>dard 270, section 5.3.6.5/163/83/83/83/8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.SC-5Effective 1/1/06


Split System CoolingSingle Phase – 1½ through 5 TonsXR 12 XR 12 XR 11Table SC-6-A — Features (4TTR2) (2TTR2) (2TTR1)• SEER’s up to .......................................................................................................................................................................... 13 13 11.5• Climatuff compressor ........................................................................................................................................................ ✔ ✔ ✔• Comfort”R” mode approved .............................................................................................................................................. ✔ ✔ ✔• DuraTuff base, fast complete drain, weatherproof .............................................................................................................. ✔ ✔ ✔• Quick-Sess cabinet, service access & refriger<strong>an</strong>t connections with full coil protection ....................................................... ✔ ✔ ✔• Spine Fin coil ..................................................................................................................................................................... ✔ ✔ ✔• Factory installed start kit ......................................................................................................................................................... 1-2 & 5 1-2 —• Factory supplied charge ......................................................................................................................................................... R-410A R-22 R-22• Glossy corrosion resist<strong>an</strong>t finish ............................................................................................................................................. ✔ ✔ ✔• High pressure switch .............................................................................................................................................................. — ✔ ✔• Internal high / low pressure & temperature protection ............................................................................................................. ✔ ✔ ✔• Liquid line filter drier - factory installed .................................................................................................................................... ✔ ✔ ✔• Tarpaulin gray cabinet ............................................................................................................................................................ ✔ ✔ ✔• 10-year limited warr<strong>an</strong>ty on compressor, outdoor coil & 5 years on parts (<strong>Residential</strong>) .......................................................... ✔ ✔ ✔• Extended warr<strong>an</strong>ties available ............................................................................................................................................ ✔ ✔ ✔PHASED OUTTable SC-6-B — Optional AccessoriesAY28X079 ............... Evap. Defrost Control Kit .......................................................................................................................... ✔ ✔ ✔BAY24X045 ............. ID F<strong>an</strong> Delay Relay Kit ............................................................................................................................. ✔ ✔ ✔BAYCCHT300 ......... Cr<strong>an</strong>kcase Heater Kit (Reciprocating Compressors) ................................................................................ 1½-2 1½-2 1½-5BAYCCHT301 ......... Cr<strong>an</strong>kcase Heater Kit (Scroll Compressors) ............................................................................................. 2½-5 2½-5 —BAYECMT001 ......... Extreme Condition Mounting Kit ............................................................................................................... ✔ ✔ ✔BAYISLT101 ............ Rubber Isolators ....................................................................................................................................... ✔ ✔ ✔BAYKSKT257 .......... Start Kit (Reciprocating Compressors) ..................................................................................................... — — 2½-5BAYKSKT260 .......... Start Kit (Scroll Compressors) .................................................................................................................. 2½-4 2½-5 —BAYKSKT261 .......... Start Kit (Base 1 & 2TTR1018, 024 only) (Reciprocating Compressors) ................................................... — — 1½-2BAYLEGS002 .......... Snow Legs - Base <strong>an</strong>d Cap 6" High (Black) ............................................................................................. ✔ ✔ ✔BAYLEGS003 .......... 4" Extension (Black) ................................................................................................................................. ✔ ✔ ✔BAYLOAM103 ......... Low Ambient Kit ....................................................................................................................................... — ✔ 2½-5BAYLOAM104 ......... Low Ambient Kit with Start Kit .................................................................................................................. — — 1½-2BAYSDEN001 ......... Single Cylinder Compressor Enclosures .................................................................................................. — — 1½-2BAYSDEN003 ......... Small Scroll Compressor Enclosures ........................................................................................................ — 2½-4 —BAYSEAC001 ......... Seacoast Kit ............................................................................................................................................. ✔ ✔ ✔PHASED OUTTable SC-6-C — Comfort ControlsTAYASCT501A56 .. Anti-Short Cycle Timer ............................................................................................................................. ✔ ✔ ✔TAYSENS100A3 .... Outdoor Temp. Sensor (with case) ........................................................................................................... ✔ ✔ ✔TAYSTAT241 .......... M<strong>an</strong>ual 2 Htg/1 Clg ................................................................................................................................... ✔ ✔ ✔TAYSTAT250B ........ Outdoor Thermostat ................................................................................................................................. ✔ ✔ ✔TAYSTAT300C ........ XT300C Prog., 7 Day, A/M,1Htg/1Clg ...................................................................................................... ✔ ✔ ✔TAYSTAT302C ........ XT302C Prog., 7 Day, A/M,2Htg/2Clg ...................................................................................................... ✔ ✔ ✔TAYSTAT340 .......... Prog., 5/2 Day, M<strong>an</strong>ual, 1 Htg/1 Clg ......................................................................................................... ✔ ✔ ✔TAYSTAT350 .......... Prog., 5/2 Day, M<strong>an</strong>ual, 2 (Gas) Htg/1Clg ................................................................................................ ✔ ✔ ✔TAYSTAT370 .......... Electronic, 1Htg (Gas) /1 Clg ( Non Prog.) ................................................................................................ ✔ ✔ ✔TAYSTAT3712 ....... Electronic, 1Htg (Elec.) /1 Clg ( Non Prog.) .............................................................................................. ✔ ✔ ✔TAYSTAT375 .......... Electronic, 2Htg (Gas/Elec.) 2 Clg (Non Prog.) Field Selectable ............................................................... ✔ ✔ ✔TAYSTAT380 .......... Electronic, 2 Htg (Gas)/ 1 Clg (Non Prog.) ................................................................................................ ✔ ✔ ✔TCONT200A ............ Electronic, 1Htg/1Clg (Gas/Elec./Oil) ........................................................................................................ ✔ ✔ ✔TCONT401A ............ 2Heat/1Clg (Heat Pump/A/C) ................................................................................................................... ✔ ✔ ✔TCONT402A ............ 3Heat/2Clg (Heat Pump/A/C) ................................................................................................................... ✔ ✔ ✔TCONT600A ............ 1Heat/1Clg (Heat Pump/A/C) ................................................................................................................... ✔ ✔ ✔TCONT602A ............ 2Heat/1Clg (Heat Pump/A/C) ................................................................................................................... ✔ ✔ ✔TCONT800A ............ 2Heat/1Clg (Heat Pump/A/C) ................................................................................................................... ✔ ✔ ✔TCONT802A ............ 3Heat/2Clg (Heat Pump/A/C) ................................................................................................................... ✔ ✔ ✔TCONT803A ............ 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control ..................................................................................... ✔ ✔ ✔1 Requires Subbase.2 Specifically designed for electric heat applications (inst<strong>an</strong>t on f<strong>an</strong>)3 Used with TAYSTAT300C, TAYSTAT302C4 Use with BAY28X182, BAY28X1835 Not for use with programmable thermostats6 Activated on Power Off.PHASED OUTEffective 1/1/06SC-6For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System CoolingSingle Phase – 1 through 5 TonsTable SC-7-A — XB13 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.XB132TTB3018A1000A 200-230/1/60 17,000 TXV-NB 26 29 26 182 76 8 15 5/82TTB3024A1000A 200-230/1/60 23,000 TXV-NB 33 29 26 195 78 12 20 3/42TTB3030A1000A 200-230/1/60 28,500 TXV-NB 33 33 30 225 78 13 20 3/42TTB3036A1000A 208-230/1/60 34,500 TXV-NB 33 33 30 220 76 18 30 7/82TTB3042A1000A 200-230/1/60 40,500 TXV-NB 33 37 34 283 79 21 35 7/82TTB3048A1000A 200-230/1/60 46,500 TXV-NB 41 37 34 307 79 25 40 1 1 /82TTB3060A1000A 208-230/1/60 58,500 TXV-NB 41 37 34 303 79 32 50 1 1 /81/45/165/163/83/83/83/8Table SC-7-B — XB12 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TTB2018A1000A 200-230/1/60 18,000 .051 26 29 26 172 81 10 15 5/81/4XB122TTB2024A1000A 200-230/1/60 24,000 .057 29 29 26 188 82 11 15PHASED OUT3/42TTB2030A1000A 208-230/1/60 30,000 .065 29 29 26 180 79 18 30 3/42TTB2036A1000A 208-230/1/60 36,000 .071 33 29 26 195 79 21 35 7/82TTB2042A1000A 208-230/1/60 42,000 .077 33 33 30 216 N/A 23 40 7/82TTB2048A1000A 208-230/1/60 48,000 .086 37 33 30 248 78 26 45 1 1 /82TTB2060A1000A 208-230/1/60 60,000 1 37 33 30 271 79 38 60 1 1 /85/165/163/83/83/83/8Table SC-7-C — XB10 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.PHASED OUT2TTB0030A1000A 200-230/1/60 30,000 .065 26 29 26 169 81 17 30 3/42TTB0036A1000A 200-230/1/60 36,000 .071 26 29 26 175 80 20 35 7/82TTB0042A1000A 200-230/1/60 42,000 .075 26 29 26 208 81 23 40 7/82TTB0048A1000A 200-230/1/60 48,000 .080 26 29 26 218 82 26 45 1 1 /82TTB0060A1000A 200-230/1/60 60,000 1 33 33 30 256 83 35 60 1 1 /85/163/83/83/83/8XB10Table SC-7-D — XB10 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.TTB012C100A 200-230/1/60PHASED12,000 .049 24 18 18 118OUT82 11 15 5/8TTB018C100A 200-230/1/60 18,000 .049 24 18 18 118 82 11 15 5/8TTB024C100A 208-230/1/60 24,000 .057 24 18 18 130 80 15 25 3/41 Indoor Metering device TXV only.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accord<strong>an</strong>ce with ARI St<strong>an</strong>dard 270, section 5.3.6.1/41/45/16XB10For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.SC-7Effective 1/1/06


Split System CoolingSingle Phase – 1 through 5 TonsXB 13 XB 12 XB 10 XB 10Table SC-8-A — Features (2TTB3) (2TTB2) (2TTB0) (TTB)• SEER’s up to ..................................................................................................................................................... 13.25 12.50 10.50 10.50• Climatuff compressor ................................................................................................................................... ✔ ✔ ✔ ✔• Comfort”R” mode approved ......................................................................................................................... ✔ ✔ ✔ ✔• DuraTuff base, fast complete drain, weatherproof ......................................................................................... ✔ ✔ ✔ ✔• Quick-Sess cabinet, service access & refriger<strong>an</strong>t connections with full coil protection .................................. ✔ ✔ ✔ ✔• Spine Fin coil ................................................................................................................................................ ✔ ✔ ✔ ✔• Compressor sump heat - factory installed .......................................................................................................... 5 — — —• Factory supplied charge .................................................................................................................................... R-22 R-22 R-22 R-22• Glossy corrosion resist<strong>an</strong>t finish ........................................................................................................................ ✔ ✔ ✔ ✔• Internal high / low pressure & temperature protection ........................................................................................ ✔ ✔ ✔ ✔• Liquid line filter drier - factory installed ............................................................................................................... ✔ ✔ ✔ ✔• Polyslate gray cabinet ....................................................................................................................................... ✔ ✔ ✔ ✔• Quick start kit - factory installed ......................................................................................................................... 1½-2½,3½-5 1½-2 — —• 5 year limited warr<strong>an</strong>ty on compressor, outdoor coil & 5 years on parts (<strong>Residential</strong>) ........................................ ✔ ✔ ✔ ✔• Extended warr<strong>an</strong>ties available ....................................................................................................................... ✔ ✔ ✔ ✔Table SC-8-B — Optional AccessoriesAY28X079 ............... Evap. Defrost Control Kit ..................................................................................................... ✔ ✔ ✔ ✔BAYCCHT300 ......... Cr<strong>an</strong>kcase Heater Kit (Reciprocating Compressors) ........................................................... 1½-2½,3½-4 1½-2 2½-5 1-2BAYCCHT301 ......... Cr<strong>an</strong>kcase Heater Kit (Scroll Compressors) ........................................................................ 3 2½-5 — —BAYECMT001 ......... Extreme Condition Mounting Kit .......................................................................................... ✔ ✔ ✔ —BAYISLT100 ............ Rubber Isolators (012, 018 & 024 only) ............................................................................... — — — ✔BAYISLT101 ............ Rubber Isolators .................................................................................................................. ✔ ✔ ✔ —BAYKSKT257 .......... Start Kit (Reciprocating Compressors) ................................................................................ — — 2½-5 —BAYKSKT260 .......... Start Kit (Scroll Compressors) ............................................................................................. 3 2½-5 — —BAYKSKT261 .......... Start Kit (18" only - TTB012,018 & 024) (Reciprocating Compressors) ................................ — — — 1-2BAYLEGS002 .......... Snow Legs - Base <strong>an</strong>d Cap 6" High (Black) ........................................................................ ✔ ✔ ✔ —BAYLEGS003 .......... 4" Extension (Black) ............................................................................................................ ✔ ✔ ✔ —BAYLOAM103 ......... Low Ambient Kit .................................................................................................................. ✔ ✔ ✔ —BAYLOAM104 ......... Low Ambient Control Kit ...................................................................................................... — — — ✔BAYSDEN001 ......... Single Cylinder Compressor Enclosures ............................................................................. 1½-2½ 1½-2 2½-3 1-2BAYSDEN002 ......... Two Cylinder Compressor Enclosures ................................................................................. — — 3½-5 —BAYSDEN003 ......... Small Scroll Compressor Enclosures ................................................................................... 3 2½-4 — —BAYSDEN004 ......... Large Scroll Compressor Enclosures .................................................................................. 5 5 — —BAYSEAC001 ......... Seacoast Kit ........................................................................................................................ ✔ ✔ ✔ —Table SC-8-C — Comfort ControlsSee Comfort Controls/Zone Sensors SectionPHASED OUTPHASED OUTAY28X092 ............... Heat/Cool ( Horiz.) Therm. .................................................................................................. ✔ ✔ ✔BAYSTAT304 .......... Cooling Only w/ F<strong>an</strong> Switch ................................................................................................. ✔ ✔ ✔BAYSTAT305 .......... Heat/Cool ( Vertical ) Therm. ............................................................................................... ✔ ✔ ✔TAYASCT501A56 .. Anti-Short Cycle Timer ........................................................................................................ ✔ ✔ ✔TAYSENS100A3 .... Outdoor Temp. Sensor (with case) ...................................................................................... ✔ ✔ ✔TAYSTAT250B ........ Outdoor Thermostat ............................................................................................................ ✔ ✔ ✔TAYSTAT300C ........ XT300C Prog., 7 Day, A/M,1Htg/1Clg .......................................................................... ✔ ✔ ✔TAYSTAT370 .......... Electronic, 1Htg (Gas) /1 Clg ( Non Prog.) ........................................................................... ✔ ✔ ✔TAYSTAT3712 ....... Electronic, 1Htg (Elec.) /1 Clg ( Non Prog.) ......................................................................... ✔ ✔ ✔TCONT200A ............ Electronic, 1Htg/1Clg (Gas/Elec./Oil) ................................................................................... ✔ ✔ ✔TCONT401A ............ 2Heat/1Clg (Heat Pump/A/C) .............................................................................................. ✔ ✔ ✔TCONT402A ............ 3Heat/2Clg (Heat Pump/A/C) .............................................................................................. ✔ ✔ ✔TCONT600A ............ 1Heat/1Clg (Heat Pump/A/C) .............................................................................................. ✔ ✔ ✔TCONT602A ............ 2Heat/1Clg (Heat Pump/A/C) .............................................................................................. ✔ ✔ ✔TCONT800A ............ 2Heat/1Clg (Heat Pump/A/C) .............................................................................................. ✔ ✔ ✔TCONT802A ............ 3Heat/2Clg (Heat Pump/A/C) .............................................................................................. ✔ ✔ ✔TCONT803A ............ 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control ................................................................ ✔ ✔ ✔1 Requires Subbase.2 Specifically designed for electric heat applications (inst<strong>an</strong>t on f<strong>an</strong>)3 Used with TAYSTAT300C, TAYSTAT302C4 Use with BAY28X182, BAY28X1835 Not for use with programmable thermostats6 Activated on Power Off.PHASED OUTEffective 1/1/06SC-8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System CoolingThree Phase – 2½ through 6 TonsTable SC-9-A — 2TTA0 Split System Cooling — Three PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TTA02TTA0030A3000A 200-230/3/60 30,000 .065 26 29 26 175 80 13 20 3/42TTA0036A3000A 200-230/3/60 36,000 .073 26 29 26 179 79 15 25 7/82TTA0042A3000A 200-230/3/60 42,000 .075 29 29 26 211 83 18 30 7/82TTA0048A3000A 200-230/3/60 48,000 .083 29 29 26 216 82 20 30 1 1 /82TTA0060A3000A 200-230/3/60 60,000 1 33 33 30 255 82 27 45 1 1 /82TTA0072A3000A 200-230/3/60 72,000 1 41 37 34 297 81 26 45 1 1 /82TTA0030A4000A 460/3/60 30,000 .065 26 29 26 175 80 7 15 3/42TTA0036A4000A 460/3/60 36,000 .073 26 29 26 179 79 8 15 7/82TTA0042A4000A 460/3/60 42,000 .075 29 29 26 211 83 9 15 7/82TTA0048A4000A 460/3/60 48,000 .083 29 29 26 216 82 10 15 1 1 /82TTA0060A4000A 460/3/60 60,000 1 33 33 30 255 82 13 20 1 1 /82TTA0072A4000A 460/3/60 72,000 1 41 37 34 297 81 14 20 1 1 /85/163/83/83/83/83/85/163/83/83/83/83/8Table SC-9-B — 2TTA3 Split System Cooling — Three PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TTA3030A3000A 200-230/3/60 30,000 TXV-NB 33 33 30 225 78 9 15 3/4 5/162TTA3036A3000A 200-230/3/60 36,000 TXV-NB 33 33 30 216 76 13 20 7/8 3/82TTA3042A3000A 200-230/3/60 42,000 TXV-NB 33 37 34 245 79 13 20 7/8 3/82TTA3048A3000A 200-230/3/60 48,000 TXV-NB 41 37 34 303 79 16 25 1 1 /8 3/82TTA3060A3000A 200-230/3/60 60,000 TXV-NB 41 37 34 292 79 23 40 1 1 /8 3/82TTA32TTA3030A4000A 460/3/60 30,000 TXV-NB 33 33 30 225 78 5 15 3/42TTA3036A4000A 460/3/60 36,000 TXV-NB 33 33 30 219 76 7 15 7/82TTA3042A4000A 460/3/60 42,000 TXV-NB 33 37 34 246 79 7 15 7/82TTA3048A4000A 460/3/60 48,000 TXV-NB 41 37 34 305 79 9 15 1 1 /85/163/83/83/82TTA3060A4000A 460/3/60 60,000 TXV-NB 41 37 34 293 79 10 15 1 1 /83/8Table SC-9-C — 2TTA2 Split System Cooling — Three PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TTA2030A3000A 200-230/3/60 30,000 .065 29 29 26 177 79 12 20 3/42TTA2036A3000A 200-230/3/60 36,000 .071 33 29 26 192 79 15 25 7/82TTA2042B3000A 200-230/3/60 42,000 .077 33 33 30 212 79 17 25 7/82TTA2048A3000A 200-230/3/60 48,000 .086 37 33 30 242 78 20 35 1 1 /85/163/83/83/82TTA22TTA2060A3000A 200-230/3/60 60,000 1 37 33 30 258 79 24 40 1 1PHASED OUT/82TTA2030A4000A 460/3/60 30,000 .065 29 29 26 180 79 6 15 3/42TTA2036A4000A 460/3/60 36,000 .071 33 29 26 191 79 8 15 7/82TTA2042B4000A 460/3/60 42,000 .077 33 33 30 212 79 8 15 7/82TTA2048A4000A 460/3/60 48,000 .086 37 33 30 241 78 10 15 1 1 /82TTA2060A4000A 460/3/60 60,000 1 37 33 30 258 79 12 20 1 1 /81 Indoor Metering device TXV only.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accord<strong>an</strong>ce with ARI St<strong>an</strong>dard 270, section 5.3.6.3/85/163/83/83/83/8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.SC-9Effective 1/1/06


Split System CoolingThree Phase – 2½ through 6 TonsTable SC-10-A — Features 2TTA0 2TTA3 2TTA2• SEER's up to .................................................................................................................................................................. 11.75 14.50 12.50• Climatuff compressor ................................................................................................................................................ ✔ ✔ ✔• Comfort”R” mode approved ...................................................................................................................................... ✔ ✔ ✔• DuraTuff base, fast complete drain, weatherproof ...................................................................................................... ✔ ✔ ✔• Quick-Sess cabinet, service access & refriger<strong>an</strong>t connections with full coil protection ............................................... ✔ ✔ ✔• Spine Fin coil ............................................................................................................................................................. ✔ ✔ ✔• Compressor sump heat - factory installed ....................................................................................................................... 2½-6 2½-5 2½-5• Factory supplied charge ................................................................................................................................................. R-22 R-22 R-22• Glossy corrosion resist<strong>an</strong>t finish ..................................................................................................................................... ✔ ✔ ✔• Internal high / low pressure & temperature protection ..................................................................................................... ✔ ✔ ✔• Liquid line filter drier - factory installed ............................................................................................................................ ✔ ✔ ✔• Low pressure switch ....................................................................................................................................................... ✔ ✔ —• PolySlate gray cabinet .................................................................................................................................................... ✔ ✔ ✔• 5-year limited warr<strong>an</strong>ty on compressor, <strong>an</strong>d 1 year on coil <strong>an</strong>d parts (Commercial) ....................................................... ✔ ✔ ✔• 5-year limited warr<strong>an</strong>ty on compressor, coil <strong>an</strong>d 1 year on parts (<strong>Residential</strong>) ................................................................ ✔ ✔ ✔• Extended warr<strong>an</strong>ties available .................................................................................................................................... ✔ ✔ ✔PHASED OUT PHASED OUT PHASED OUTTable SC-10-B — Optional AccessoriessAY28X079 .................................... Evaporator Defrost Control .......................................................................................... ✔ ✔ ✔BAYECMT001 .............................. Extreme Condition Mounting Kit ................................................................................... ✔ ✔ ✔BAYISLT101 ................................. Rubber Isolators ........................................................................................................... ✔ ✔ ✔BAYLEGS002 ............................... Snow Legs - Base <strong>an</strong>d Cap 6" High (Black) ................................................................. ✔ ✔ ✔BAYLEGS003 ............................... 4" Extension (Black) ..................................................................................................... ✔ ✔ ✔BAYLOAM103 .............................. Electronic Head Pressure Control ................................................................................ ✔ ✔ ✔BAYSDEN001 .............................. Single Cylinder Compressor Enclosures ...................................................................... 2½-3 2½ —BAYSDEN002 .............................. Two Cylinder Compressor Enclosures ......................................................................... 3½-5 3½-4 —BAYSDEN003 .............................. Small Scroll Compressor Enclosures ........................................................................... — 3 2½-4BAYSDEN004 .............................. Large Scroll Compressor Enclosures ........................................................................... 6 5 5BAYSEAC001 .............................. Seacoast Kit ................................................................................................................. ✔ ✔ ✔TAYASCT501A12 ...................... Anti-Short Cycle Timer ................................................................................................. ✔ ✔ ✔Table SC-10-C — Comfort ControlsTAYSENS100A ........................... Outdoor Temp. Sensor (with case) ..............................................................................TAYSTAT241 ............................... M<strong>an</strong>ual 2 Stg Htg/1 Clg ................................................................................................TAYSTAT250B ............................. Outdoor Thermostat .....................................................................................................TAYSTAT300C ............................ XT300C Prog.,7 Day,A/M,1Htg/1Clg ............................................................................TAYSTAT340 ............................... Prog., 5/2 Day, M<strong>an</strong>ual, 1 Htg/1 Clg .............................................................................TAYSTAT350 ............................... Prog., 5/2 Day, M<strong>an</strong>ual, 2 (Gas) Htg/1 Clg ...................................................................TAYSTAT370 ............................... Electronic, 1Htg(Gas)/1Clg(Non Prog.) ........................................................................TAYSTAT371 ............................... Electronic, 1Htg(Elec)/1Clg(Non Prog.) ........................................................................TAYSTAT380 ............................... Electronic, 2 Htg (Gas) 1 Clg(Non Prog.) .....................................................................TCONT200A ................................. Electronic, 1Htg/1Clg (Gas/Elec./Oil) ...........................................................................TCONT401A ................................. 2Heat/1Clg (Heat Pump/A/C) .......................................................................................TCONT402A ................................. 3Heat/2Clg (Heat Pump/A/C) .......................................................................................TCONT600A ................................. 1Heat/1Clg (Heat Pump/A/C) .......................................................................................TCONT602A ................................. 2Heat/1Clg (Heat Pump/A/C) .......................................................................................TCONT800A ................................. 2Heat/1Clg (Heat Pump/A/C) .......................................................................................TCONT802A ................................. 3Heat/2Clg (Heat Pump/A/C) .......................................................................................TCONT803A ................................. 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control ........................................................1 Do not use with programmable thermostats.2 Activated on Power Off.See Comfort Controls/Zone Sensors SectionSee Comfort Controls/Zone Sensors Section✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔Effective 1/1/06SC-10For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System CoolingThree Phase – 7½ through 20 TonsTTA – 7½ through 20 Tons• New ReliaTel controls option• (1) <strong>Tr<strong>an</strong>e</strong> 3-D ® Scroll compressor (TTA090-120A)• (2) <strong>Tr<strong>an</strong>e</strong> Scroll compressors (TTA120-240B) with independent refriger<strong>an</strong>t circuits• (2) M<strong>an</strong>ifolded Scroll compressors withunloading capability (TTA120 & 180C)• Single point power supply• Compressor motor overload protection• Control tr<strong>an</strong>sformer• High <strong>an</strong>d low pressure cut-out switches• Liquid line filter drier, factory installed• Service valves with pressure taps• Internal pressure relief valves(TTA120B,120C,150B)• Holding charge of Nitrogen• Copper tube, aluminum plate fin coils• Low ambient cooling to 50°F as shipped.• Low ambient cooling to 0°F with accessoryhead pressure control• Mounting/lifting rails under base• UL listed• 5 year compressor warr<strong>an</strong>ty(TTA090-120A/TTA120-180B/TTA120-180C)• 1 year compressor warr<strong>an</strong>ty (TTA240B)• 1 year limited parts warr<strong>an</strong>ty• Optional Extended Warr<strong>an</strong>tiesTable SC-11-A — TTA Split System Cooling — Single CompressorFactory Nom. Cap. Uncrated Shipping Line SizeModel Installed Power Cooling Dimensions(in.) Mfg. Weight Sound1 Max. OD ODNumber Option Supply (BTUH) H W L Pl<strong>an</strong>t (lbs.) Rating MCA* Fuse* Gas Liq.TTA090A300F — 208/230/3/60 92,000 39 34 41 SPR 370 8.8 34.5 50 1 3 /8TTA090A30SF Epoxy Coil 208-230/3/60 92,000 39 34 41 SPR 370TTA090A30RF ReliaTel, No LCI Board 208-230/3/60 92,000 39 34 41 SPR 370TTA090A30TF ReliaTel, No LCI Board W/Epoxy Coil 208-230/3/60 92,000 39 34 41 SPR 370TTA090A30UF ReliaTel, W/LCI Board 208-230/3/60 92,000 39 34 41 SPR 370TTA090A30WF ReliaTel, W/LCI Board & Epoxy Coil 208-230/3/60 92,000 39 34 41 SPR 3701/2TTA120A300F — 208/230/3/60 128,000 39 38 51 SPR 443 8.8 48.1 70 1 3 /8TTA120A30SF Epoxy Coil 208-230/3/60 128,000 39 38 51 SPR 443TTA120A30RF ReliaTel, No LCI Board 208-230/3/60 128,000 39 38 51 SPR 443TTA120A30TF ReliaTel, No LCI Board W/Epoxy Coil 208-230/3/60 128,000 39 38 51 SPR 443TTA120A30UF ReliaTel, W/LCI Board 208-230/3/60 128,000 39 38 51 SPR 443TTA120A30WF ReliaTel, W/LCI Board & Epoxy Coil 208-230/3/60 128,000 39 38 51 SPR 4431/2TTA090A400F — 460/3/60 92,000 39 34 41 SPR 370 8.8 18.1 25 1 3 /8TTA090A40SF Epoxy Coil 460/3/60 92,000 39 34 41 SPR 370TTA090A40RF ReliaTel, No LCI Board 460/3/60 92,000 39 34 41 SPR 370TTA090A40TF ReliaTel, No LCI Board W/Epoxy Coil 460/3/60 92,000 39 34 41 SPR 370TTA090A40UF ReliaTel, W/LCI Board 460/3/60 92,000 39 34 41 SPR 370TTA090A40WF ReliaTel, W/LCI Board & Epoxy Coil 460/3/60 92,000 39 34 41 SPR 3701/2TTA120A400F — 460/3/60 128,000 39 38 51 SPR 443 8.8 23.3 35 1 3 /8TTA120A40SF Epoxy Coil 460/3/60 128,000 39 38 51 SPR 443TTA120A40RF ReliaTel, No LCI Board 460/3/60 128,000 39 38 51 SPR 443TTA120A40TF ReliaTel, No LCI Board W/Epoxy Coil 460/3/60 128,000 39 38 51 SPR 443TTA120A40UF ReliaTel, W/LCI Board 460/3/60 128,000 39 38 51 SPR 443TTA120A40WF ReliaTel, W/LCI Board & Epoxy Coil 460/3/60 128,000 39 38 51 SPR 4431/2TTA090AW00F — 575/3/60 92,000 39 34 41 SPR 370 8.8 14.5 20 1 3 /8TTA090AW0SF Epoxy Coil 575/3/60 92,000 39 34 41 SPR 370TTA090AW0RF ReliaTel, No LCI Board 575/3/60 92,000 39 34 41 SPR 370TTA090AW0TF ReliaTel, No LCI Board W/Epoxy Coil 575/3/60 92,000 39 34 41 SPR 370TTA090AW0UF ReliaTel, W/LCI Board 575/3/60 92,000 39 34 41 SPR 370TTA090AW0WF ReliaTel, W/LCI Board & Epoxy Coil 575/3/60 92,000 39 34 41 SPR 3701/2TTA120AW00F — 575/3/60 128,000 39 38 51 SPR 443 8.8 18.8 25 1 3 /8TTA120AW0SF Epoxy Coil 575/3/60 128,000 39 38 51 SPR 443TTA120AW0RF ReliaTel, No LCI Board 575/3/60 128,000 39 38 51 SPR 443TTA120AW0TF ReliaTel, No LCI Board W/Epoxy Coil 575/3/60 128,000 39 38 51 SPR 443TTA120AW0UF ReliaTel, W/LCI Board 575/3/60 128,000 39 38 51 SPR 443TTA120AW0WF ReliaTel, W/LCI Board & Epoxy Coil 575/3/60 128,000 39 38 51 SPR 4431 Sound rated in accord<strong>an</strong>ce with A.R.I. St<strong>an</strong>dard 270.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.SC-111/2Effective 1/1/06


Split System CoolingThree Phase – 10 through 20 TonsTable SC-12-A — TTA Split System Cooling — Dual CompressorFactory Nom. Cap. Uncrated Shipping Line SizeModel Installed Power Cooling Dimensions(in.) Mfg. Weight Sound1 Max. OD ODNumber Option Supply (BTUH) H W L Pl<strong>an</strong>t (lbs.) Rating MCA* Fuse* Gas Liq.TTA120B300E — 208-230/3/60 126,000 39 38 51 SPR 481 8.8 47.9 60 1 1 /8TTA120B30SE Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 481TTA120B30RE ReliaTel, No LCI Board 208-230/3/60 126,000 39 38 51 SPR 481TTA120B30TE ReliaTel, No LCI Board w/Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 481TTA120B30UE ReliaTel, W/LCI Board 208-230/3/60 126,000 39 38 51 SPR 481TTA120B30WE ReliaTel, W/LCI Board & Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 4813/8TTA150B300E — 208/230/3/60 148,000 39 38 51 SPR 481 8.8 55.5 70 1 1 /8TTA150B30SE Epoxy Coil 208-230/3/60 148,000 39 38 51 SPR 481TTA150B30RE ReliaTel, No LCI Board 208-230/3/60 148,000 39 38 51 SPR 481TTA150B30TE ReliaTel, No LCI Board w/Epoxy Coil 208-230/3/60 148,000 39 38 51 SPR 481TTA150B30UE ReliaTel, W/LCI Board 208-230/3/60 148,000 39 38 51 SPR 481TTA150B30WE ReliaTel, W/LCI Board & Epoxy Coil 208-230/3/60 148,000 39 38 51 SPR 4813/8TTA180B300F — 208/230/3/60 182,000 39 34 88 SPR 764 8.8 62.7 80 1 3 /8TTA180B30SF Epoxy Coil 208-230/3/60 182,000 39 34 88 SPR 764TTA180B30RF ReliaTel, No LCI Board 208-230/3/60 182,000 39 34 88 SPR 764TTA180B30TF ReliaTel, No LCI Board w/Epoxy Coil 208-230/3/60 182,000 39 34 88 SPR 764TTA180B30UF ReliaTel, W/LCI Board 208-230/3/60 182,000 39 34 88 SPR 764TTA180B30WF ReliaTel, W/LCI Board & Epoxy Coil 208-230/3/60 182,000 39 34 88 SPR 7641/2TTA240B300F — 208/230/3/60 246,000 45 44 94 SPR 915 8.8 87.8 100 1 3 /8TTA240B30SF Epoxy Coil 208-230/3/60 246,000 45 44 94 SPR 948TTA240B30RF ReliaTel, No LCI Board 208-230/3/60 246,000 45 44 94 SPR 948TTA240B30TF ReliaTel, No LCI Board w/Epoxy Coil 208-230/3/60 246,000 45 44 94 SPR 948TTA240B30UF ReliaTel, W/LCI Board 208-230/3/60 246,000 45 44 94 SPR 948TTA240B30WF ReliaTel, W/LCI Board & Epoxy Coil 208-230/3/60 246,000 45 44 94 SPR 9481/2TTA120B400E — 460/3/60 126,000 39 38 51 SPR 481 8.8 23.9 30 1 1 /8TTA120B40SE Epoxy Coil 460/3/60 126,000 39 38 51 SPR 481TTA120B40RE ReliaTel, No LCI Board 460/3/60 126,000 39 38 51 SPR 481TTA120B40TE ReliaTel, No LCI Board w/Epoxy Coil 460/3/60 126,000 39 38 51 SPR 481TTA120B40UE ReliaTel, W/LCI Board 460/3/60 126,000 39 38 51 SPR 481TTA120B40WE ReliaTel, W/LCI Board & Epoxy Coil 460/3/60 126,000 39 38 51 SPR 4813/8TTA150B400E — 460/3/60 148,000 39 38 51 SPR 481 8.8 28.1 35 1 1 /8TTA150B40SE Epoxy Coil 460/3/60 148,000 39 38 51 SPR 481TTA150B40RE ReliaTel, No LCI Board 460/3/60 148,000 39 38 51 SPR 481TTA150B40TE ReliaTel, No LCI Board w/Epoxy Coil 460/3/60 148,000 39 38 51 SPR 481TTA150B40UE ReliaTel, W/LCI Board 460/3/60 148,000 39 38 51 SPR 481TTA150B40WE ReliaTel, W/LCI Board & Epoxy Coil 460/3/60 148,000 39 38 51 SPR 4813/8TTA180B400F — 460/3/60 182,000 39 34 88 SPR 764 8.8 32.9 45 1 3 /8TTA180B40SF Epoxy Coil 460/3/60 182,000 39 34 88 SPR 764TTA180B40RF ReliaTel, No LCI Board 460/3/60 182,000 39 34 88 SPR 764TTA180B40TF ReliaTel, No LCI Board w/Epoxy Coil 460/3/60 182,000 39 34 88 SPR 764TTA180B40UF ReliaTel, W/LCI Board 460/3/60 182,000 39 34 88 SPR 764TTA180B40WF ReliaTel, W/LCI Board & Epoxy Coil 460/3/60 182,000 39 34 88 SPR 7641/2TTA240B400F — 460/3/60 246,000 45 44 94 SPR 915 8.8 42.5 50 1 3 /8TTA240B40SF Epoxy Coil 460/3/60 246,000 45 44 94 SPR 915TTA240B40RF ReliaTel, No LCI Board 460/3/60 246,000 45 44 94 SPR 915TTA240B40TF ReliaTel, No LCI Board w/Epoxy Coil 460/3/60 246,000 45 44 94 SPR 915TTA240B40UF ReliaTel, W/LCI Board 460/3/60 246,000 45 44 94 SPR 915TTA240B40WF ReliaTel, W/LCI Board & Epoxy Coil 460/3/60 246,000 45 44 94 SPR 9151 Sound rated in accord<strong>an</strong>ce with A.R.I. St<strong>an</strong>dard 270.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.1/2Effective 1/1/06SC-12For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System CoolingThree Phase – 10 through 20 TonsTable SC-13-A — TTA Split System Cooling — Dual Compressor (continued)Factory Nom. Cap. Uncrated Shipping Line SizeModel Installed Power Cooling Dimensions(in.) Mfg. Weight Sound1 Max. OD ODNumber Option Supply (BTUH) H W L Pl<strong>an</strong>t (lbs.) Rating MCA* Fuse* Gas Liq.TTA120BW00E — 575/3/60 126,000 39 38 51 SPR 481 8.8 19.1 25 1 1 /8TTA120BW0SE Epoxy Coil 575/3/60 126,000 39 38 51 SPR 481TTA120BW0RE ReliaTel, No LCI Board 575/3/60 126,000 39 38 51 SPR 481TTA120BW0TE ReliaTel, No LCI Board w/Epoxy Coil 575/3/60 126,000 39 38 51 SPR 481TTA120BW0UE ReliaTel, W/LCI Board 575/3/60 126,000 39 38 51 SPR 481TTA120BW0WE ReliaTel, W/LCI Board & Epoxy Coil 575/3/60 126,000 39 38 51 SPR 4813/8TTA150BW00E — 575/3/60 148,000 39 38 51 SPR 481 8.8 21.6 25 1 1 /8TTA150BW0SE Epoxy Coil 575/3/60 148,000 39 38 51 SPR 481TTA150BW0RE ReliaTel, No LCI Board 575/3/60 148,000 39 38 51 SPR 481TTA150BW0TE ReliaTel, No LCI Board w/Epoxy Coil 575/3/60 148,000 39 38 51 SPR 481TTA150BW0UE ReliaTel, W/LCI Board 575/3/60 148,000 39 38 51 SPR 481TTA150BW0WE ReliaTel, W/LCI Board & Epoxy Coil 575/3/60 148,000 39 38 51 SPR 4813/8TTA180BW00F — 575/3/60 182,000 39 34 88 SPR 764 8.8 26.3 35 1 3 /8TTA180BW0SF Epoxy Coil 575/3/60 182,000 39 34 88 SPR 764TTA180BW0RF ReliaTel, No LCI Board 575/3/60 182,000 39 34 88 SPR 764TTA180BW0TF ReliaTel, No LCI Board w/Epoxy Coil 575/3/60 182,000 39 34 88 SPR 764TTA180BW0UF ReliaTel, W/LCI Board 575/3/60 182,000 39 34 88 SPR 764TTA180BW0WF ReliaTel, W/LCI Board & Epoxy Coil 575/3/60 182,000 39 34 88 SPR 7641/2TTA240BW00F — 575/3/60 246,000 45 44 94 SPR 915 8.8 34.2 45 1 3 /8TTA240BW0SF Epoxy Coil 575/3/60 246,000 45 44 94 SPR 915TTA240BW0RF ReliaTel, No LCI Board 575/3/60 246,000 45 44 94 SPR 915TTA240BW0TF ReliaTel, No LCI Board w/Epoxy Coil 575/3/60 246,000 45 44 94 SPR 915TTA240BW0UF ReliaTel, W/LCI Board 575/3/60 246,000 45 44 94 SPR 915TTA240BW0WF ReliaTel, W/LCI Board & Epoxy Coil 575/3/60 246,000 45 44 94 SPR 9151 Sound rated in accord<strong>an</strong>ce with A.R.I. St<strong>an</strong>dard 270.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.1/2For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.SC-13Effective 1/1/06


Split System CoolingThree Phase – 10 through 15 TonsTable SC-14-A — TTA Split System Cooling — Dual M<strong>an</strong>ifolded Compressors with Single Refriger<strong>an</strong>t CircuitsModel Installed Power Cooling Dimensions(in.) Mfg. Weight Sound1 Max. OD ODNumber Option Supply (BTUH) H W L Pl<strong>an</strong>t (lbs.) Rating MCA* Fuse* Gas Liq.TTA120C300G — 208-230/3/60 126,000 39 38 51 SPR 492 8.8 49.4 60 1 3 /8TTA120C30SG Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 492TTA120C30RG ReliaTel, No LCI Board 208-230/3/60 126,000 39 38 51 SPR 492TTA120C30TG ReliaTel, No LCI Board w/Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 492TTA120C30UG ReliaTel, W/LCI Board 208-230/3/60 126,000 39 38 51 SPR 492TTA120C30WG ReliaTel, W/LCI Board & Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 4921/2TTA180C300G — 208-230/3/60 182,000 39 34 88 SPR 764 8.8 62.7 80 1 5 /8TTA180C30SG Epoxy Coil 208-230/3/60 182,000 39 34 88 SPR 764TTA180C30RG ReliaTel, No LCI Board 208-230/3/60 182,000 39 34 88 SPR 764TTA180C30TG ReliaTel, No LCI Board w/Epoxy Coil 208-230/3/60 182,000 39 34 88 SPR 764TTA180C30UG ReliaTel, W/LCI Board 208-230/3/60 182,000 39 34 88 SPR 764TTA180C30WG ReliaTel, W/LCI Board & Epoxy Coil 208-230/3/60 182,000 39 34 88 SPR 764v5/8TTA120C400G — 460/3/60 126,000 39 38 51 SPR 492 8.8 25.2 30 1 3 /8TTA120C40SG Epoxy Coil 460/3/60 126,000 39 38 51 SPR 492TTA120C40RG ReliaTel, No LCI Board 460/3/60 126,000 39 38 51 SPR 492TTA120C40TG ReliaTel, No LCI Board w/Epoxy Coil 460/3/60 126,000 39 38 51 SPR 492TTA120C40UG ReliaTel, W/LCI Board 460/3/60 126,000 39 38 51 SPR 492TTA120C40WG ReliaTel, W/LCI Board & Epoxy Coil 460/3/60 126,000 39 38 51 SPR 4921/2TTA180C400G — 460/3/60 182,000 39 34 88 SPR 764 8.8 32.9 45 1 5 /8TTA180C40SG Epoxy Coil 460/3/60 182,000 39 34 88 SPR 764TTA180C40RG ReliaTel, No LCI Board 460/3/60 182,000 39 34 88 SPR 764TTA180C40TG ReliaTel, No LCI Board w/Epoxy Coil 460/3/60 182,000 39 34 88 SPR 764TTA180C40UG ReliaTel, W/LCI Board 460/3/60 182,000 39 34 88 SPR 764TTA180C40WG ReliaTel, W/LCI Board & Epoxy Coil 460/3/60 182,000 39 34 88 SPR 7645/8TTA120CW00G — 575/3/60 126,000 39 38 51 SPR 492 8.8 19.8 25 1 3 /8TTA120CW0SG Epoxy Coil 575/3/60 126,000 39 38 51 SPR 492TTA120CW0RG ReliaTel, No LCI Board 575/3/60 126,000 39 38 51 SPR 492TTA120CW0TG ReliaTel, No LCI Board w/Epoxy Coil 575/3/60 126,000 39 38 51 SPR 492TTA120CW0UG ReliaTel, W/LCI Board 575/3/60 126,000 39 38 51 SPR 492TTA120CW0WG ReliaTel, W/LCI Board & Epoxy Coil 575/3/60 126,000 39 38 51 SPR 4921/2TTA180CW00G — 575/3/60 182,000 39 34 88 SPR 764 8.8 26.3 35 1 5 /8TTA180CW0SG Epoxy Coil 575/3/60 182,000 39 34 88 SPR 764TTA180CW0RG ReliaTel, No LCI Board 575/3/60 182,000 39 34 88 SPR 764TTA180CW0TG ReliaTel, No LCI Board w/Epoxy Coil 575/3/60 182,000 39 34 88 SPR 764TTA180CW0UG ReliaTel, W/LCI Board 575/3/60 182,000 39 34 88 SPR 764TTA180CW0WG ReliaTel, W/LCI Board & Epoxy Coil 575/3/60 182,000 39 34 88 SPR 7641 Sound rated in accord<strong>an</strong>ce with A.R.I. St<strong>an</strong>dard 270.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.5/8Effective 1/1/06SC-14For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System CoolingThree Phase – 7½ through 20 TonsTable SC-15-A — Optional AccessoriesModelNumber Description Used WithBAY24X042 ....................... F<strong>an</strong> Control Relay .......................................... TTA090-120A, 120-240B, 120-180C(Outdoor Thermostat 45°F to -10°F)BAYASCT00139 ............. Anti-Short-Cycle Timer ................................... TTA090-120A, 120-240B, 120-180CBAYGARD024A ................ Coil Guard Kit ................................................. TTA090ABAYGARD026A ................ Coil Guard Kit ................................................. TTA150B, TTA120A, B, CBAYGARD039A ................ Coil Guard Kit ................................................. TTA180B, CBAYGARD042A ................ Coil Guard Kit ................................................. TTA240BBAYHGBP002C1 ............. Hot Gas Bypass Kit ........................................ TTA090-120ABAYHGBP003C12 .......... Hot Gas Bypass Kit ........................................ TTA180B, C, TTA240B, TTA120B, C; TTA150BBAYISLT004A ................... Rubber-In-Shear Isolators .............................. TTA090ABAYISLT005A ................... Rubber-In-Shear Isolators .............................. TTA120A, B, CBAYISLT009A ................... Rubber-In-Shear Isolators .............................. TTA150-180B, TTA180CBAYISLT010A ................... Rubber-In-Shear Isolators .............................. TTA240BBAYISLT023A ................... Steel Spring Isolators ..................................... TTA090-120A, 120CBAYISLT024A ................... Steel Spring Isolators ..................................... TTA180B, TTA180C, TTA120-150BBAYISLT025A ................... Steel Spring Isolators ..................................... TTA240BBAYLOAM015A0 .............. Head Pressure Control – 575V ...................... TTA090-180AW, BW, CWBAYLOAM326A40 ........... Head Pressure Control – 230V ...................... TTA090A3BAYLOAM327A40 ........... Head Pressure Control – 230V ...................... TTA120A3, B3, 120C3, 150B3BAYLOAM329A240 ....... Head Pressure Control – 230V ...................... TTA180B3, C3BAYLOAM328A240 ......... Head Pressure Control – 230V ...................... TTA240B3BAYLOAM425A0 .............. Head Pressure Control – 460V ...................... TTA090A4BAYLOAM426A40 ........... Head Pressure Control – 460V ...................... TTA120A4, B4, 150B4, 120C4BAYLOAM428A240 ......... Head Pressure Control – 460V ...................... TTA180B4, C4BAYLOAM427A240 ......... Head Pressure Control – 460V ...................... TTA240B4BAYLOAM429Bqw ........... Low Ambient F<strong>an</strong> Cycle Control .................... TTA090-240A,B,CBAYLOAMW22A0 ............. Head Pressure Control – 575V ...................... TTA120, 150, 240AW, BW, CWBAYRLAY0023 ................ Time Delay Relay ........................................... TTA120-240B, TTA120-180C, TTA090-120ABAYSTAT033A .................. Outdoor Thermostat 45°F to -10°F ................ TTA090-120A, TTA120-240B, TTA120-180CTable SC-15-B — Comfort ControlsModelNumber Description Used WithBAY28X1825 .................... 1-Stage Htg/Clg .............................................. TTA090-120ABAY28X1835 .................... 2-Stage Htg/Clg .............................................. TTA090-120A, 120-240B, 120-180CBAY28X1865 .................... 2-Stage Clg ..................................................... TTA090-120A, 120-240B, 120-180CBAY28X1846 .................... Subbase (Automatic/M<strong>an</strong>ual Ch<strong>an</strong>geover) ..... BAY28X183BAY28X1857 .................... Subbase (M<strong>an</strong>ual Ch<strong>an</strong>geover) ...................... BAY28X182, 183BAY28X1876 ..................... Subbase (Automatic Ch<strong>an</strong>geover) ................. BAY28X182, 183, 186BAY28X1903 .................... Locking Thermostat Cover ............................. All Room ThermostatsBAYBASE006A0 ............... Subbase 2-Stage Htg/Clg ............................... BAYSTAT040B with TTA090-120A,120-240B or 120-180CBAYBASE008A .................. Subbase 1-Stage Htg/Clg ............................... BAYSTAT040B with TTA090-120ABAYSENS033A .................. Remote Wall Sensor ....................................... BAYSTAT040BBAYSENS034A0 ............... Duct Temperature Sensor ............................... BAYSTAT040BBAYSTAT040B80 .............. Programmable Thermostat ............................. BAYBASE006A or BAYBASE008ATAYSENS100A .................. Outdoor Temp. Sensor (With Case) ............... TAYSTAT300C,302C,375TAYSTAT300C .................. XT 300C Prog., 7Day, A/M,1Htg/1Clg ............ All Cooling ModelsTAYSTAT302C .................. XT 302C Prog., 7Day, A/M,2Htg/2Clg ............ All Cooling ModelsTCONT200AN11AA ........... Electronic 1-Stage Htg/Clg ............................. TTA090A,120A1 Condensing unit must be on same level as or below Air H<strong>an</strong>dler. Contact Application Engineer, Clarksville, before using <strong>an</strong>y other configuration. (See Installers Guide).2 Qu<strong>an</strong>tity: 2 required on TTA180B, C; TTA240B.3 Do not use with programmable thermostats or ReliaTel model.4 Kits mount to the outdoor unit <strong>an</strong>d operate by sensing liquid.5 Requires Subbase.6 Requires BAY24X042 relay kit when used with electric heat.7 Specifically designed for electric heat applications (inst<strong>an</strong>t on f<strong>an</strong>).8 Requires BAYBASE006A or BAYBASE008A.9 Activated on Power On.0 Option is compatible for units with ReliaTel Controls.q Option is compatible for units with electric mech<strong>an</strong>ical controls only.w Kit mounts external to the outdoor unit <strong>an</strong>d operates by sensing ambient <strong>an</strong>d liquid line temperatures.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.SC-15Effective 1/1/06


Split System CoolingThree Phase – 7½ through 20 TonsTable SC-16-A — Sensors for use with ReliaTel units.Model Mfg. ShippingNumber Description Used With Pl<strong>an</strong>t WeightBAYSENS006B Single Setpoint M<strong>an</strong>ual TTA090A_OR, OU, OT, OW- CK/001 1Ch<strong>an</strong>geover Zone SensorTTA240B_OR, OU, OT, OWBAYSENS008B Dual Setpoint M<strong>an</strong>ual or Auto TTA090A_OR, OU, OT, OW- CK/001 1Ch<strong>an</strong>geover Zone SensorTTA240B_OR, OU, OT, OWBAYSENS010B Dual Setpoint M<strong>an</strong>ual or Auto TTA090A_OR, OU, OT, OW- CK/001 1Ch<strong>an</strong>geover Zone Sensor with TTA240B_OR, OU, OT, OWSystem Function LightsBAYSENS013C Zone Sensor w/ Timed TTA090A_OR, OU, OT, OW- CK/001 1Override & C<strong>an</strong>celTTA240B_OR, OU, OT, OWBAYSENS014C Zone Sensor w/ Setpoint TTA090A_OR, OU, OT, OW- CK/001 1Timed Override <strong>an</strong>d C<strong>an</strong>celTTA240B_OR, OU, OT, OWBAYSENS017B Wall Mounted Zone Sensor for TTA090A_OR, OU, OT, OW- CK/001 1Remote SensingTTA240B_OR, OU, OT, OWBAYSENS019C Programmable Zone sensor TTA090A_OR, OU, OT, OW- CK/001 1NSB P<strong>an</strong>elTTA240B_OR, OU, OT, OWBAYSENS032A Remote Wall Sensor TTA090A_OR, OU, OT, OW- CK/001 1for use with BAYSENS035ATTA240B_OR, OU, OT, OWBAYSENS033A Remote Wall Sensor TTA090A-TTA240B CK/001 1for use with BAYSENS040ABAYSENS034A Remote Duct Sensor TTA090A-TTA240B CK/001 1for use with BAYSTAT040BBAYSENS035A Digital Zone Sensor with TTA090A_OR,OU,OT,OW- CK/001 1LCD DisplayTTA240B_OR,OU,OT,OWTable SC-16-B — ControlsBAYICSI003A <strong>Tr<strong>an</strong>e</strong> Communication Interface (TCI) TTA090_OR,OT- CK/001 1TTA240_OR,OTBAYLTCI002B LonTalk Communication Interface (LCI) TTA090_OR,OT- CK/001 1TTA240_OR,OTEffective 1/1/06SC-16For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


7 ½ - 20 Tons withReliaTel ControlsTTA090-120, TTA120-240, TTA120-180CProtection/Operation Timings <strong>an</strong>d FeaturesAnti Short Cycle Timer (ASCT) Function — Provides a three (3)minute minimum “ON” time <strong>an</strong>d a three (3) minute minimum “OFF” timefor compressors, enh<strong>an</strong>ces compressor reliability by ensuring proper oilreturn. St<strong>an</strong>dardBuilt In F<strong>an</strong> Delay Relay (FDR) Function — Provides custom indoorf<strong>an</strong> timing sequences for the different types of equipment, enh<strong>an</strong>cingefficiency <strong>an</strong>d reliability. St<strong>an</strong>dardBuilt In Night Set Back <strong>an</strong>d Unoccupied Functions1 — When usinga st<strong>an</strong>dard dual setpoint/auto ch<strong>an</strong>ge over Zone Sensor Module (ZSM),this function is enabled by applying a short across terminal J6-11 <strong>an</strong>dJ6-12. Sets cooling setpoint up a minimum of 7°F, sets heating setpointback a minimum of 7°F, <strong>an</strong>d forces f<strong>an</strong> operation to automatic.(requires time clock accessory or field supplied/installed switch orcontacts).Built In “TEST” Mode — Aids in quick verification of system<strong>an</strong>d control operation, exercises both hardware <strong>an</strong>d software(no special tools required). St<strong>an</strong>dardBuilt In Unoccupied Mode1 — When using a st<strong>an</strong>dard singlesetpoint/m<strong>an</strong>ual ch<strong>an</strong>ge over Zone Sensor Module (ZSM), this functionis enabled by applying a short across terminal J6-11 <strong>an</strong>d J6-12. Forcesf<strong>an</strong> operation to automatic. (requires time clock accessory or fieldsupplied/installed switch or contacts.)Direct Digital Control (DDC)1 — Proportional Integral (PI) control.Proportional – sets corrective action proportional to deviationfrom setpoint. Integral – fine tunes the rate of corrective actionproportional to the error (results in superior space temperature control).St<strong>an</strong>dardIncreased Reliability — Fewer components (moving electromech<strong>an</strong>icalparts), less likelihood of equipment down time orfailure. St<strong>an</strong>dardIntegral Electric Heat Staging1 — Stages electric heaters “OFF” <strong>an</strong>d“ON”, eliminating the use of outdated sequencers. St<strong>an</strong>dardIntelligent Fallback1 — A built in Default Control provides adaptiveoperation, which allows the equipment to continueto operate, providing comfort in the event of certain component failures.Also, allows emergency operation without a Zone Sensor Module(ZSM). St<strong>an</strong>dardLow Ambient Start Timer (LAST) Function — Bypasses lowpressure control when a compressor starts, eliminating nuis<strong>an</strong>cecompressor lock outs. St<strong>an</strong>dardLower Installation Cost — Using a st<strong>an</strong>dard Zone Sensor Module(ZSM), control voltage wiring may be run up to five (5) times furtherth<strong>an</strong> <strong>an</strong>y electromech<strong>an</strong>ical system, with no increase in wire gauge.Example: Electromech<strong>an</strong>ical System –30 feet maximum using 22 gauge wire. Micro Control System – 150feet using 22 gauge wire. St<strong>an</strong>dardOn Board Diagnostics1 — Assist with equipment troubleshooting, ifa problem occurrence should take place. St<strong>an</strong>dardRemote Sensing1 — All st<strong>an</strong>dard Zone Sensor Modules(ZSMs) have remote sensing capabilities, typically achieved by using<strong>an</strong> expensive program-mable thermostat <strong>an</strong>d remote sensor withelectromech<strong>an</strong>ical equipment. Accessory (requires use of remotesensor).Space Temperature Averaging1 — All st<strong>an</strong>dard Zone SensorModules (ZSMs) have space temperature averaging capabilities,typically achieved by using <strong>an</strong> expensive programmable thermostat<strong>an</strong>d minimum of four (4) remote sensors with electromech<strong>an</strong>icalequipment. Averaging with ReliaTel c<strong>an</strong> be achieved with two(2) sensors.Time Delay Relay (TDR) Function — Provides <strong>an</strong> incrementalstaging delay between compressors, minimizes equipment currentinrush <strong>an</strong>d consumption by keeping compressors from startingsimult<strong>an</strong>eously. St<strong>an</strong>dardLow Pressure <strong>an</strong>d High Pressure Compressor Lockout — 3 tripswill lockout control.1 Denotes features lost from utilizing st<strong>an</strong>dard conventional stat.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.SC-17Effective 1/1/06


7 ½ - 20 Tons with ReliaTelMicro ControlOperation With A ThermostatWhen the ReliaTel RTRM Thermostat Interface is used, equipment operationdiffers signific<strong>an</strong>tly. The basic equipment protection features remain intact, <strong>an</strong>d thefollowing features <strong>an</strong>d benefits are lost:• Direct Digital Control (DDC) –Proportional Integral (PI) control is lost,equipment is controlled by a thermostator generic building automation systemdevice.• Intelligent Fall back is lost, if a failureoccurs in the device controlling theequipment, operation will cease.• Installation is more costly, with theaddition of a thermostat or genericcontrol, the control wiring size must beincreased.• Remote Sensing capabilities are lost,unless generic control being applied c<strong>an</strong>accomplish this.• Space Temperature Averagingcapabilities are lost, unless genericcontrol being applied c<strong>an</strong> accomplishthis.• Built In Night Set Back <strong>an</strong>d Unoccupiedfunctions are lost, unlessgeneric control being applied c<strong>an</strong>accomplish this.• Built In Unoccupied Mode is lost,unless generic control being appliedc<strong>an</strong> accomplish this.Effective 1/1/06SC-18For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System Heat PumpsSingle Phase – 1½ through 5 TonsTable SH-1-A — XL19i Weathertron ® Split System Heat Pump — Single PhaseNom. Cap. Uncrated Shipping Line SizeModel Power Cooling Metering Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Device H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TWZ9030B1000A 200/230/1/60 30,000 TXV-NB 50 37 34 443 74 19 30 7/82TWZ9036B1000A 200/230/1/60 36,000 TXV-NB 50 37 34 440 74 22 36 7/82TWZ9048B1000A 200/230/1/60 48,000 TXV-NB 50 37 34 448 74 25 40 1 1 /83/83/83/8XL19i2TWZ9060B1000A 200/230/1/60 60,000 TXV-NB 50 37 34 455 74 37 60 1 1 /8Note: Because of limited capabilities, please refer to product data for approved combinations.Table SH-1-B — XL16i Weathertron ® Split System Heat Pump — Single PhaseNom. Cap. Uncrated Shipping Line SizeModel Power Cooling Metering Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Device H W D (lbs.) Rating MCA* Fuse* Gas Liq.4TWX6024B1000A 230/1/60 24,000 TXV-NB 44 33 30 260 72 12 20 5/8 5/164TWX6036B1000A 230/1/60 36,000 TXV-NB 46 37 34 305 71 24 40 3/4 3/84TWX6048B1000A 230/1/60 48,000 TXV-NB 50 37 34 320 74 29 50 7/8 3/84TWX6060B1000A 230/1/60 60,000 TXV-NB 50 37 34 362 74 35 60 7/8 3/83/8XL16iTable SC-1-C — XL15i Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TWX5024A1000A 208/230/1/60 24,000 TXV-NB 42 37 34 273 74 14 20 3/4 5/162TWX5030A1000A 208/230/1/60 30,000 TXV-NB 46 37 34 290 71 20 30 3/4 5/162TWX5036A1000A 208/230/1/60 36,000 TXV-NB 50 37 34 304 74 20 30 7/8 3/82TWX5042A1000A 208/230/1/60 42,000 TXV-NB 50 37 34 314 72 23 35 7/8 3/82TWX5048A1000A 208/230/1/60 48,000 TXV-NB 50 37 34 342 74 26 40 1 1 /8 3/8XL15iTable SH-1-D — XL14i Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TWX4018B1000A 200/230/1/60 18,000 TXV-NB 40 33 30 242 71 8 15 5/82TWX4024B1000A 200/230/1/60 24,000 TXV-NB 44 33 30 256 74 11 15 3/42TWX4030B1000A 208/230/1/60 30,000 TXV-NB 42 37 34 275 73 18 30 3/42TWX4036B1000A 208/230/1/60 36,000 TXV-NB 46 37 34 294 74 21 35 7/82TWX4042B1000A 208/230/1/60 42,000 TXV-NB 50 37 34 309 74 24 40 7/81/45/165/163/83/8XL14iXL14i2TWX4048B1000A 208/230/1/60 48,000 TXV-NB 50 37 34 313 74 28 45 1 1 /82TWX4060B1000A 208/230/1/60 60,000 TXV-NB 50 37 34 340 74 34 50 1 1 /8Table SH-1-E — XL14i Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.4TWX4018B1000A 200/230/1/60 18,000 TXV-NB 40 33 30 224 74 10 15 1/2 1/44TWX4024B1000A 200/230/1/60 24,000 TXV-NB 48 33 30 239 74 13 20 5/8 5/164TWX4030B1000A 208/230/1/60 30,000 TXV-NB 48 33 30 242 71 20 30 3/4 5/164TWX4036B1000A 208/230/1/60 36,000 TXV-NB 46 37 34 259 72 21 35 3/4 3/84TWX4042B1000A 208/230/1/60 42,000 TXV-NB 50 37 34 274 74 25 40 3/4 3/84TWX4048B1000A 208/230/1/60 48,000 TXV-NB 50 37 34 280 74 30 50 7/8 3/84TWX4060B1000A 208/230/1/60 60,000 TXV-NB 50 37 34 318 74 36 60 7/8 3/8* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accord<strong>an</strong>ce with ARI St<strong>an</strong>dard 270, section 5.3.6.3/83/8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.SH-1 Effective 1/1/06


Split System Heat PumpsSingle Phase – 1½ through 5 TonsXL19i XL16i XL15i XL14i XL14iTable SH-2-A — Features (2TWZ9) (4TWX6) (2TWX5) (2TWX4) (4TWX4)• SEER’s up to .......................................................................................................... 17.90 17.00 16.50 15.00 15.00• HSPF’s up to .......................................................................................................... 8.8 9.2 9.0 9.0 9.0• Climatuff compressor ........................................................................................ 2 1 - staged ✔ ✔ ✔• Comfort”R” mode approved ............................................................................. ✔ ✔ ✔ ✔ ✔• DuraTuff base, fast complete drain, weatherproof ............................................. ✔ ✔ ✔ ✔ ✔• Quick-Sess cabinet, service access & .............................................................. ✔ ✔ ✔ ✔ ✔refriger<strong>an</strong>t connections with full coil protection• Spine Fin coil ..................................................................................................... ✔ ✔ ✔ ✔ ✔• Weatherguard II top .......................................................................................... ✔ ✔ ✔ ✔ ✔• Compressor sound enclosure ................................................................................ ✔ ✔ ✔ ✔ ✔• Compressor sump heat - factory installed .............................................................. 2½-5 5 2-4 1½-2 & 3½-5 1½-2• Factory supplied charge ......................................................................................... R-22 R-410A R-22 R-22 R-410A• Glossy corrosion resist<strong>an</strong>t finish ............................................................................ ✔ ✔ ✔ ✔ ✔• High pressure switch .............................................................................................. — ✔ — — ✔• Internal high / low pressure & temperature protection ............................................ ✔ ✔ ✔ ✔ ✔• Liquid line filter drier - factory installed ................................................................... ✔ ✔ ✔ ✔ ✔• Quick start kit - factory installed ............................................................................. 2½-5 5 — 1½-2 & 5 1½-2 & 5• Seacoast shield - factory installed .......................................................................... ✔ ✔ ✔ ✔ ✔• Tarpaulin gray cabinet ............................................................................................ ✔ ✔ ✔ ✔ ✔• 10-year limited warr<strong>an</strong>ty on compressor, outdoor coil & parts .............................. ✔ ✔ ✔ ✔ ✔(<strong>Residential</strong>)• Extended warr<strong>an</strong>ties available ............................................................................... ✔ ✔ ✔ ✔ ✔Table SH-2-B — Optional AccessoriesAY28X079 .............. Evaporator defrost control kit ..................................................... ✔ ✔ ✔ ✔ ✔BAYCCHT301 ........ Cr<strong>an</strong>k Case Heater Kit (Scroll Compressors) ............................ — 2-4 — 2½-3 2½-5BAYECMT001 ........ Extreme Condition Mounting Kit ................................................ ✔ ✔ ✔ ✔ ✔BAYISLT101 .......... Rubber Isolators ........................................................................ ✔ ✔ ✔ ✔ ✔BAYKSKT260 ........ Quick start kit (21/2 - 4 ton) (Scroll Compressors) ..................... — 2-4 2-4 2½-4 2½-4BAYLEGS002 ........ Snow Legs - Base <strong>an</strong>d Cap 6" High (Black) .............................. ✔ ✔ ✔ ✔ ✔BAYLEGS003 ........ 4" Extension (Black) .................................................................. ✔ ✔ ✔ ✔ ✔TAYASCT501A12 . Anti-Short Cycle Timer .............................................................. ✔ ✔ ✔ ✔ ✔Comfort Controls — See Comfort Controls/Zone Sensors Section1 Do not use with programmable thermostats.2 Activated on Power Off.Effective 1/1/06SH-2For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System Heat PumpsSingle Phase – 1½ through 5 TonsTable SH-3-A — XR14 Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.XR144TWR4018A1000A 200-230/1/60 18,000 TXV-NB 37 33 30 236 76 10 15 1/24TWR4024A1000A 200-230/1/60 24,000 TXV-NB 41 33 30 251 74 13 20 5/84TWR4030A1000A 208-230/1/60 30,000 TXV-NB 41 33 30 253 74 20 30 3/44TWR4036A1000A 208-230/1/60 36,000 TXV-NB 37 37 34 276 77 21 35 3/44TWR4042A1000A 208-230/1/60 42,000 TXV-NB 41 37 34 290 77 25 40 3/44TWR4048A1000A 208-230/1/60 48,000 TXV-NB 41 37 34 297 76 30 50 7/84TWR4060A1000A 208-230/1/60 60,000 TXV-NB 41 37 34 335 79 36 60 7/81/45/165/163/83/83/83/8Table SH-3-B — XR14 Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.XR142TWR4018A1000A 200-230/1/60 18,000 TXV-NB 33 33 30 229 75 8 15 5/82TWR4024A1000A 200-230/1/60 24,000 TXV-NB 37 33 30 242 76 11 15 3/42TWR4030A1000A 208-230/1/60 30,000 TXV-NB 33 37 34 254 76 18 30 3/42TWR4036A1000A 208-230/1/60 36,000 TXV-NB 37 37 34 273 78 21 35 7/82TWR4042A1000A 208-230/1/60 42,000 TXV-NB 41 37 34 286 77 24 40 7/82TWR4048A1000A 208-230/1/60 48,000 TXV-NB 41 37 34 291 77 28 45 1 1 /82TWR4060A1000A 208-230/1/60 60,000 TXV-NB 41 37 34 315 76 34 50 1 1 /81/45/165/163/83/83/83/8Table SH-3-C — XR13 Weathertron ® Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.XR132TWR3018A1000A 200-230/1/60 18,000 TXV-NB 33 29 26 202 73 8 15 5/82TWR3024A1000A 200-230/1/60 24,000 TXV-NB 33 29 26 205 76 12 20 3/42TWR3030A1000A 200-230/1/60 30,000 TXV-NB 37 33 30 242 76 13 20 3/42TWR3036A1000A 200-230/1/60 36,000 TXV-NB 37 37 34 292 76 19 30 7/82TWR3042A1000A 200-230/1/60 42,000 TXV-NB 41 37 34 309 78 21 35 7/82TWR3048A1000A 200-230/1/60 48,000 TXV-NB 41 37 34 315 76 25 40 1 1 /82TWR3060A1000A 208-230/1/60 60,000 TXV-NB 41 37 34 321 73 32 50 1 1 /8* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accord<strong>an</strong>ce with ARI St<strong>an</strong>dard 270, section 5.3.6.1/45/165/163/83/83/83/8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.SH-3 Effective 1/1/06


Split System Heat PumpsSingle Phase – 1½ through 5 TonsXR14 XR14 XR13Table SH-4-A — Features (4TWR4) (2TWR4) (2TWR3)• SEER’s up to ......................................................................................................................................................... 14.00 14.00 14.00• HSPF’s up to ......................................................................................................................................................... 9.0 9.0 8.5• Climatuff compressor ....................................................................................................................................... ✔ ✔ ✔• Comfort”R” mode approved ............................................................................................................................ ✔ ✔ ✔• DuraTuff base, fast complete drain, weatherproof ............................................................................................ ✔ ✔ ✔• Quick-Sess cabinet, service access & refriger<strong>an</strong>t connections with full coil protection .................................... ✔ ✔ ✔• Spine Fin coil .................................................................................................................................................... ✔ ✔ ✔• Compressor sound enclosure ............................................................................................................................... ✔ ✔ ✔• Compressor sump heat - factory installed ............................................................................................................. 1½-5 1½-5 1½-5• Factory supplied charge ........................................................................................................................................ R-410A R-22 R-22• Glossy corrosion resist<strong>an</strong>t finish ........................................................................................................................... ✔ ✔ ✔• High pressure switch ............................................................................................................................................. ✔ — —• Low pressure switch ............................................................................................................................................. — — ✔• Internal high / low pressure & temperature protection ........................................................................................... ✔ ✔ ✔• Liquid line filter drier - factory installed .................................................................................................................. ✔ ✔ ✔• Quick start kit - factory installed ............................................................................................................................ 1½-2,5 1½-2,5 1½-5• Tarpaulin gray cabinet ........................................................................................................................................... ✔ ✔ ✔• 10-year limited warr<strong>an</strong>ty on compressor, outdoor coil & 5 years on parts (<strong>Residential</strong>) ........................................ ✔ ✔ ✔• Extended warr<strong>an</strong>ties available .............................................................................................................................. ✔ ✔ ✔Table SH-4-B — Optional AccessoriesAY28X079 .............. Evap. Defrost Control Kit .......................................................................................................... ✔ ✔ ✔BAYECMT001 ........ Extreme Condition Mounting Kit ............................................................................................... ✔ ✔ ✔BAYISLT101 .......... Rubber Isolators ....................................................................................................................... ✔ ✔ ✔BAYKSKT260 ........ Start Kit (Scroll Compressors) .................................................................................................. 2½-4 2½-4 —BAYLEGS002 ........ Snow Legs - Base <strong>an</strong>d Cap 6" High (Black) ............................................................................. ✔ ✔ ✔BAYLEGS003 ........ 4" Extension (Black) ................................................................................................................. ✔ ✔ ✔BAYLOAM103 ........ Low Ambient Kit ....................................................................................................................... — ✔ ✔BAYSEAC001 ........ Seacoast Kit ............................................................................................................................. ✔ ✔ ✔TAYASCT501A12 . Anti-Short Cycle Timer ............................................................................................................. ✔ ✔ ✔Comfort Controls — See Comfort Controls/Zone Sensors Section1 Do not use with programmable thermostats.2 Activated on Power Off.Effective 1/1/06SH-4For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System Heat PumpsSingle Phase – 1½ through 5 TonsTable SH-5-A — XR12 Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.4TWR2018A1000A 200/230/1/60 18,000 .047 33 33 30 221 77 10 15 1/21/4XR124TWR2024A1000A 200/230/1/60 24,000 .053 33 33 30 225 78 14 20PHASED OUT5/84TWR2030A1000A 208/230/1/60 30,000 .059 33 33 30 234 74 20 30 3/44TWR2036A1000A 208/230/1/60 36,000 .063 41 33 30 257 77 21 35 3/44TWR2042A1000A 208/230/1/60 42,000 .069 41 33 30 262 79 26 45 3/44TWR2048A1000A 208/230/1/60 48,000 .075 33 37 34 271 79 30 50 7/84TWR2060A1000A 208/230/1/60 60,000 1 41 37 34 302 81 36 60 7/85/165/163/83/83/83/8Table SH-5-B — XR12 Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TWR2018A1000A 200/230/1/60 18,000 .049 26 29 26 176 79 10 15 5/81/4XR122TWR2024A1000A 200/230/1/60 24,000 .059 29 29 26 191 78 13 20PHASED OUT3/42TWR2030B1000A 208/230/1/60 30,000 .065 29 29 26 187 99 18 30 3/42TWR2036A1000A 208/230/1/60 36,000 .071 33 33 30 233 77 21 35 7/82TWR2042A1000A 208/230/1/60 42,000 .077 33 33 30 229 79 24 40 7/82TWR2048A1000B 208/230/1/60 48,000 .086 37 33 30 256 99 26 45 1 1 /82TWR2060A1000A 208/230/1/60 60,000 1 41 37 34 316 80 37 60 1 1 /85/165/163/83/83/83/8Table SH-5-C — XR11 Weathertron ® Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TWR1018A1000A 200/230/1/60 18,000 0.049 26 29 26 168 77 10 15 5/81/4XR112TWR1024A1000A 200/230/1/60 24,000 0.057 26 29 26 176 77 15 25PHASED OUT3/42TWR1030A1000A 200/230/1/60 30,000 0.069 29 29 26 187 79 18 30 3/42TWR1036A1000A 200/230/1/60 36,000 0.069 29 29 26 190 79 21 35 7/82TWR1042A1000A 200/230/1/60 42,000 0.077 33 33 30 253 79 23 40 7/82TWR1048A1000A 200/230/1/60 48,000 0.083 33 33 30 259 80 30 50 1 1 /82TWR1060A1000A 200/230/1/60 60,000 1 33 37 34 292 81 34 50 1 1 /81 Indoor Metering device TXV only.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accord<strong>an</strong>ce with ARI St<strong>an</strong>dard 270, section 5.3.6.5/165/163/83/83/83/8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.SH-5 Effective 1/1/06


Split System Heat PumpsSingle Phase – 1½ through 5 TonsXR12 XR12 XR11Table SH-6-A — Features (4TWR2) (2TWR2) (2TWR1)• SEER’s up to .................................................................................................................................................................. 13.00 13.00 11.50• HSPF’s up to .................................................................................................................................................................. 9.25 10.15 8.50• Climatuff compressor ................................................................................................................................................ ✔ ✔ ✔• Comfort”R” mode approved ...................................................................................................................................... ✔ ✔ ✔• DuraTuff base, fast complete drain, weatherproof ...................................................................................................... ✔ ✔ ✔• Quick-Sess cabinet, service access & refriger<strong>an</strong>t connections with full coil protection ............................................... ✔ ✔ ✔• Spine Fin coil ............................................................................................................................................................. ✔ ✔ ✔• Factory installed start kit ................................................................................................................................................. 1-2 & 5 1-2 —• Factory supplied charge ................................................................................................................................................. R-410A R-22 R-22• Glossy corrosion resist<strong>an</strong>t finish ..................................................................................................................................... ✔ ✔ ✔• High pressure switch ...................................................................................................................................................... ✔ — —• Internal high / low pressure & temperature protection ..................................................................................................... ✔ ✔ ✔• Liquid line filter drier - factory installed ............................................................................................................................ ✔ ✔ ✔• Tarpaulin gray cabinet .................................................................................................................................................... ✔ ✔ ✔• 10-year limited warr<strong>an</strong>ty on compressor, outdoor coil & 5 years on parts (<strong>Residential</strong>) .................................................. ✔ ✔ ✔• Extended warr<strong>an</strong>ties available ........................................................................................................................................ ✔ ✔ ✔PHASED OUTTable SH-6-B — Optional AccessoriesAY28X079 ............... Evap. Defrost Control Kit .................................................................................................................. ✔ ✔ ✔BAY24X045 ............. ID F<strong>an</strong> Delay Relay Kit ..................................................................................................................... ✔ ✔ ✔BAYCCHT300 ......... Cr<strong>an</strong>kcase Heater Kit (Reciprocating Compressors) ........................................................................ 1½-2 1½-2 1½-5BAYCCHT301 ......... Cr<strong>an</strong>kcase Heater Kit (Scroll Compressors) ..................................................................................... 2½-5 2½-5 —BAYECMT001 ......... Extreme Condition Mounting Kit ....................................................................................................... ✔ ✔ ✔BAYISLT101 ............ Rubber Isolators ............................................................................................................................... ✔ ✔ ✔BAYKSKT257 .......... Start Kit (Reciprocating Compressors) ............................................................................................. — — 2½-5BAYKSKT260 .......... Start Kit (Scroll Compressors) .......................................................................................................... 2½-4 2½-5 —BAYLEGS002 .......... Snow Legs - Base <strong>an</strong>d Cap 6" High (Black) ..................................................................................... ✔ ✔ ✔BAYLEGS003 .......... 4" Extension (Black) ......................................................................................................................... ✔ ✔ ✔BAYLOAM103 ......... Low Ambient Kit ............................................................................................................................... — ✔ 2½-5BAYLOAM104 ......... Low Ambient Kit with Start Kit .......................................................................................................... — — 1½-2BAYSDEN001 ......... Single Cylinder Compressor Enclosures .......................................................................................... — — 1½-2BAYSDEN003 ......... Small Scroll Compressor Enclosures ................................................................................................ — 2½-4 —BAYSEAC001 ......... Seacoast Kit ..................................................................................................................................... ✔ ✔ ✔PHASED OUTTable SH-6-C — Comfort ControlsTAYASCT501A12 .. Anti-Short Cycle Timer ..................................................................................................................... ✔ ✔ ✔TAYSENS100A ....... Outdoor Temp. Sensor (with case) ................................................................................................... ✔ ✔ ✔TAYSTAT241 .......... M<strong>an</strong>ual 2 Htg/1 Clg ........................................................................................................................... ✔ ✔ ✔TAYSTAT250B ........ Outdoor Thermostat ......................................................................................................................... ✔ ✔ ✔TAYSTAT300C ........ XT300C Prog., 7 Day, A/M,1Htg/1Clg .............................................................................................. ✔ ✔ ✔TAYSTAT302C ........ XT302C Prog., 7 Day, A/M,2Htg/2Clg .............................................................................................. ✔ ✔ ✔TAYSTAT340 .......... Prog., 5/2 Day, M<strong>an</strong>ual, 1 Htg/1 Clg ................................................................................................. ✔ ✔ ✔TAYSTAT350 .......... Prog., 5/2 Day, M<strong>an</strong>ual, 2 (Gas) Htg/1Clg ........................................................................................ ✔ ✔ ✔TAYSTAT370 .......... Electronic, 1Htg (Gas) /1 Clg ( Non Prog.) ........................................................................................ ✔ ✔ ✔TAYSTAT371 .......... Electronic, 1Htg (Elec.) /1 Clg ( Non Prog.) ...................................................................................... ✔ ✔ ✔TAYSTAT375 .......... Electronic, 2Htg (Gas/Elec.) 2 Clg (Non Prog.) Field Selectable ....................................................... ✔ ✔ ✔TAYSTAT380 .......... Electronic, 2 Htg (Gas)/ 1 Clg (Non Prog.) ........................................................................................ ✔ ✔ ✔TCONT200A ............ Electronic, 1Htg/1Clg (Gas/Elec./Oil) ................................................................................................ ✔ ✔ ✔TCONT401A ............ 2Heat/1Clg (Heat Pump/A/C) ........................................................................................................... ✔ ✔ ✔TCONT402A ............ 3Heat/2Clg (Heat Pump/A/C) ........................................................................................................... ✔ ✔ ✔TCONT600A ............ 1Heat/1Clg (Heat Pump/A/C) ........................................................................................................... ✔ ✔ ✔TCONT602A ............ 2Heat/1Clg (Heat Pump/A/C) ........................................................................................................... ✔ ✔ ✔TCONT800A ............ 2Heat/1Clg (Heat Pump/A/C) ........................................................................................................... ✔ ✔ ✔TCONT802A ............ 3Heat/2Clg (Heat Pump/A/C) ........................................................................................................... ✔ ✔ ✔TCONT803A ............ 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control ............................................................................. ✔ ✔ ✔1 Do not use with programmable thermostats.2 Activated on Power Off.PHASED OUTEffective 1/1/06SH-6For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System Heat PumpsSingle Phase – 1½ through 5 TonsTable SH-7-A — XB13 Weathertron ® Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.XB132TWB3018A1000A 200-230/1/60 17,000 TXV-NB 33 29 26 202 74 8 15 5/82TWB3024A1000A 200-230/1/60 23,000 TXV-NB 33 29 26 205 79 12 20 3/42TWB3030A1000A 200-230/1/60 28,500 TXV-NB 37 33 30 240 79 13 20 3/42TWB3036A1000A 200-230/1/60 34,500 TXV-NB 37 37 34 291 79 19 30 7/82TWB3042A1000A 200-230/1/60 40,500 TXV-NB 41 37 34 308 80 21 35 7/82TWB3048A1000A 200-230/1/60 46,500 TXV-NB 41 37 34 312 78 25 40 1 1 /82TWB3060A1000A 208-230/1/60 58,500 TXV-NB 41 37 34 318 79 32 50 1 1 /81/45/165/163/83/83/83/8Table SH-7-B — XB12 Weathertron ® Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TWB2018A1000A 200/230/1/60 18,000 .049 26 29 26 176 81 10 15 5/81/4XB122TWB2024A1000A 200/230/1/60 24,000 .059 29 29 26 191 82 13 20PHASED OUT3/42TWB2030A1000A 208/230/1/60 30,000 .065 29 29 26 187 79 18 30 3/42TWB2036A1000A 208/230/1/60 36,000 .071 33 33 30 233 77 21 35 7/82TWB2042A1000A 208/230/1/60 42,000 .077 33 33 30 229 79 24 40 7/82TWB2048A1000A 208/230/1/60 48,000 .086 37 33 30 256 79 26 45 1 1 /82TWB2060A1000A 208/230/1/60 60,000 1 41 37 34 316 80 37 60 1 1 /85/165/163/83/83/83/8Table SH-7-C— XB10 Weathertron ® Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TWB0012A1000A 200/230/1/60 12,000 .047 26 29 26 169 79 10 15 5/81/4XB102TWB0018A1000A 200/230/1/60 18,000 .049 26 29 26 169 79 10 15PHASED OUT5/82TWB0024A1000A 200/230/1/60 24,000 .057 26 29 26 177 79 15 25 3/42TWB0030A1000A 200/230/1/60 30,000 .067 29 29 26 187 81 17 25 3/42TWB0036A1000A 200/230/1/60 36,000 .067 29 29 26 189 81 20 30 7/82TWB0042A1000A 200/230/1/60 42,000 .075 33 33 30 247 79 23 40 7/82TWB0048A1000A 200/230/1/60 48,000 .083 33 33 30 255 80 26 40 1 1 /82TWB0060A1000A 200/230/1/60 60,000 1 33 37 34 291 81 34 50 1 1 /81 Indoor Metering device TXV only.1/45/165/163/83/83/83/8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.SH-7 Effective 1/1/06


Split System Heat PumpsSingle Phase – 1½ through 5 TonsXB13 XB12 XB10Table SH-8-A — Features (2TWB3) (2TWB2) (2TWB0)• SEER’s up to ......................................................................................................................................................... 13.25 12.50 10.50• HSPF’s up to ......................................................................................................................................................... 8.0 9.10 8.15• Climatuff compressor ....................................................................................................................................... ✔ ✔ ✔• Comfort”R” mode approved ............................................................................................................................ ✔ ✔ ✔• DuraTuff base, fast complete drain, weatherproof ............................................................................................ ✔ ✔ ✔• Quick-Sess cabinet, service access & refriger<strong>an</strong>t connections with full coil protection .................................... ✔ ✔ ✔• Spine Fin coil .................................................................................................................................................... ✔ ✔ ✔• Compressor sound enclosure ............................................................................................................................... 3-4 4-5 4-5• Compressor sump heat - factory installed ............................................................................................................. 1½-5 1½-2,4-5 1½-5• Factory supplied charge ........................................................................................................................................ R-22 R-22 R-22• Glossy corrosion resist<strong>an</strong>t finish ........................................................................................................................... ✔ ✔ ✔• Low pressure switch ............................................................................................................................................. ✔ — —• Internal high / low pressure & temperature protection ........................................................................................... ✔ ✔ ✔• Liquid line filter drier - factory installed .................................................................................................................. ✔ ✔ ✔• PolySlate gray cabinet .......................................................................................................................................... ✔ ✔ ✔• Quick start kit - factory installed ............................................................................................................................ 1½-5 1½-2,5 —• 10-year limited warr<strong>an</strong>ty on compressor, outdoor coil & 5 years on parts (<strong>Residential</strong>) ........................................ ✔ ✔ ✔• Extended warr<strong>an</strong>ties available .............................................................................................................................. ✔ ✔ ✔PHASED OUTTable SH-8-B — Optional AccessoriesAY28X079 .............. Evap. Defrost Control Kit .......................................................................................................... ✔ ✔ ✔BAYCCHT301 ........ Cr<strong>an</strong>kcase Heater Kit (Scroll Compressors) ............................................................................. — 2½-3½ —BAYECMT001 ........ Extreme Condition Mounting Kit ............................................................................................... ✔ ✔ ✔BAYISLT101 .......... Rubber Isolators ....................................................................................................................... ✔ ✔ ✔BAYKSKT257 ........ Start Kit (Reciprocating Compressors) ..................................................................................... — — 1-5BAYKSKT260 ........ Start Kit (Scroll Compressors) .................................................................................................. — 2½-4 —BAYLEGS002 ........ Snow Legs - Base <strong>an</strong>d Cap 6" High (Black) ............................................................................. ✔ ✔ ✔BAYLEGS003 ........ 4" Extension (Black) ................................................................................................................. ✔ ✔ ✔BAYLOAM103 ........ Low Ambient Kit ....................................................................................................................... ✔ ✔ ✔BAYSDEN001 ........ Single Cylinder Compressor Enclosures .................................................................................. 1½-2 1-3 ?BAYSDEN002 ........ Two Cylinder Compressor Enclosures ..................................................................................... — 3½ ?BAYSDEN003 ........ Small Scroll Compressor Enclosures ....................................................................................... 2½ -— ?BAYSDEN004 ........ Large Scroll Compressor Enclosures ....................................................................................... 5 — ?BAYSEAC001 ........ Seacoast Kit ............................................................................................................................. ✔ ✔ ✔Table SH-8-C — Comfort ControlsPHASED OUTTAYASCT501A12 . Anti-Short Cycle Timer ............................................................................................................. ✔ ✔TAYSENS100A ...... Outdoor Temp. Sensor (with case) ........................................................................................... ✔ ✔TAYSTAT241 ......... M<strong>an</strong>ual 2 Htg/1 Clg ................................................................................................................... ✔ ✔TAYSTAT250B ...... Outdoor Thermostat ................................................................................................................. ✔ ✔TAYSTAT300C ...... XT300C Prog., 7 Day, A/M,1Htg/1Clg ...................................................................................... ✔ ✔TAYSTAT302C ...... XT302C Prog., 7 Day, A/M,2Htg/2Clg ...................................................................................... ✔ ✔TAYSTAT340 ......... Prog., 5/2 Day, M<strong>an</strong>ual, 1 Htg/1 Clg ......................................................................................... ✔ ✔TAYSTAT350 ......... Prog., 5/2 Day, M<strong>an</strong>ual, 2 (Gas) Htg/1Clg ................................................................................ ✔ ✔TAYSTAT370 ......... Electronic, 1Htg (Gas) /1 Clg ( Non Prog.) ............................................................................... ✔ ✔TAYSTAT371 ......... Electronic, 1Htg (Elec.) /1 Clg ( Non Prog.) .............................................................................. ✔ ✔TAYSTAT375 ......... Electronic, 2Htg (Gas/Elec.) 2 Clg (Non Prog.) Field Selectable .............................................. ✔ ✔TAYSTAT380 ......... Electronic, 2 Htg (Gas)/ 1 Clg (Non Prog.) ............................................................................... ✔ ✔TCONT200A .......... Electronic, 1Htg/1Clg (Gas/Elec./Oil) ....................................................................................... ✔ ✔TCONT401A .......... 2Heat/1Clg (Heat Pump/A/C) ................................................................................................... ✔ ✔TCONT402A .......... 3Heat/2Clg (Heat Pump/A/C) ................................................................................................... ✔ ✔TCONT600A .......... 1Heat/1Clg (Heat Pump/A/C) ................................................................................................... ✔ ✔TCONT602A .......... 2Heat/1Clg (Heat Pump/A/C) ................................................................................................... ✔ ✔TCONT800A .......... 2Heat/1Clg (Heat Pump/A/C) ................................................................................................... ✔ ✔TCONT802A .......... 3Heat/2Clg (Heat Pump/A/C) ................................................................................................... ✔ ✔TCONT803A .......... 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control .................................................................... ✔ ✔1 Do not use with programmable thermostats.2 Activated on Power Off.See Comfort Controls/Zone Sensors SectionPHASED OUTEffective 1/1/06SH-8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System Heat PumpsThree Phase – 2½ through 6 TonsTable SH-9-A — Split System Heat Pump — Three PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TWA02TWA0030A3000A 200-230/3/60 30,000 .069 29 29 26 193 82 13 20 3/42TWA0036A3000A 200-230/3/60 36,000 .069 29 29 26 192 80 15 25 7/82TWA0042A3000A 200-230/3/60 42,000 .077 33 33 30 250 81 17 30 7/82TWA0048A3000A 200-230/3/60 48,000 .083 33 33 30 254 81 19 30 1 1 /82TWA0060A3000A 200-230/3/60 60,000 1 33 37 34 289 84 25 40 1 1 /82TWA0072A3000A 200-230/3/60 72,000 1 41 37 34 327 81 26 40 1 1 /85/163/83/83/83/83/82TWA0030A4000A 460/3/60 30,000 .069 29 29 26 193 82 7 15 3/42TWA0036A4000A 460/3/60 36,000 .069 29 29 26 192 80 7 15 7/82TWA0042A4000A 460/3/60 42,000 .077 33 33 30 250 81 9 15 7/82TWA0048A4000A 460/3/60 48,000 .083 33 33 30 254 81 10 15 1 1 /82TWA0060A4000A 460/3/60 60,000 1 33 37 34 289 84 12 20 1 1 /82TWA0072A4000A 460/3/60 72,000 1 41 37 34 327 81 14 20 1 1 /85/163/83/83/83/83/8Table SH-9-B — Split System Heat Pump — Three PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TWA32TWA3030A3000A 200-230/3/60 30,000 TXV-NB 37 33 30 239 77 9 15 3/42TWA3036A3000A 200-230/3/60 36,000 TXV-NB 37 37 34 285 79 11 15 7/82TWA3042A3000A 200-230/3/60 42,000 TXV-NB 41 37 34 304 80 13 20 7/82TWA3048A3000A 200-230/3/60 48,000 TXV-NB 41 37 34 309 78 16 25 1 1 /82TWA3060A3000A 200-230/3/60 60,000 TXV-NB 41 37 34 303 73 23 40 1 1 /82TWA3030A4000A 460/3/60 30,000 TXV-NB 37 33 30 239 77 5 15 3/42TWA3036A4000A 460/3/60 36,000 TXV-NB 37 37 34 286 79 6 15 7/82TWA3042A4000A 460/3/60 42,000 TXV-NB 41 37 34 305 80 7 15 7/82TWA3048A4000A 460/3/60 48,000 TXV-NB 41 37 34 310 78 9 15 1 1 /82TWA3060A4000A 460/3/60 60,000 TXV-NB 41 37 34 304 73 11 15 1 1 /85/163/83/83/83/85/163/83/83/83/8Table SH-9-C — Split System Heat Pump — Three PhaseNom. Cap. Required Uncrated Shipping Line SizeModel Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.2TWA2030A3000A 200-230/3/60 30,000 .065 29 29 26 185 79 12 20 3/42TWA2036A3000A 200-230/3/60 36,000 .071 33 33 30 228 77 14 20 7/82TWA2042A3000A 208-230/3/60 42,000 .077 33 33 30 224 79 17 25 7/85/163/83/82TWA22TWA2048A3000A 208-230/3/60 48,000 .086 37 33 30 251 79 20 30 1 1 /8PHASED OUT2TWA2060A3000A 208-230/3/60 60,000 1 41 37 34 303 80 23 40 1 1 /82TWA2030A4000A 460/3/60 30,000 .065 29 29 26 188 79 6 15 3/42TWA2036A4000A 460/3/60 36,000 .071 33 33 30 228 77 7 15 7/82TWA2042A4000A 460/3/60 42,000 .077 33 33 30 224 79 8 15 7/82TWA2048A4000A 460/3/60 48,000 .086 37 33 30 250 79 10 15 1 1 /82TWA2060A4000A 460/3/60 60,000 1 41 37 34 303 80 12 20 1 1 /81 Indoor Metering device TXV only.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accord<strong>an</strong>ce with ARI St<strong>an</strong>dard 270, section 5.3.6.3/83/85/163/83/83/83/8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.SH-9 Effective 1/1/06


Split System Heat PumpsThree Phase – 2½ through 6 TonsTable SH-10-A — Features 2TWA0 2TWA3 2TWA2• SEER’s up to ....................................................................................................................................................... 11.75 14.50 12.5• HSPF .................................................................................................................................................................. 8.2 8.8 9.75• Climatuff compressor ..................................................................................................................................... ✔ ✔ ✔• Comfort”R” mode approved .......................................................................................................................... ✔ ✔ ✔• DuraTuff base, fast complete drain, weatherproof .......................................................................................... ✔ ✔ ✔• Quick-Sess cabinet, service access & refriger<strong>an</strong>t connections with full coil protection .................................. ✔ ✔ ✔• Spine Fin coil .................................................................................................................................................. ✔ ✔ ✔• Compressor sump heat - factory installed ........................................................................................................... 2½-6 2½-5 2½-5• Factory supplied charge ...................................................................................................................................... R-22 R-22 R-22• Glossy corrosion resist<strong>an</strong>t finish ......................................................................................................................... ✔ ✔ ✔• Internal high / low pressure & temperature protection ......................................................................................... ✔ ✔ ✔• Liquid line filter drier - factory installed ................................................................................................................ ✔ ✔ ✔• Low pressure switch ........................................................................................................................................... ✔ ✔ ✔• PolySlate gray cabinet ........................................................................................................................................ ✔ ✔ ✔• 5-year limited warr<strong>an</strong>ty on compressor, <strong>an</strong>d 1 year on coil <strong>an</strong>d parts (Commercial) ........................................... ✔ ✔ ✔• 5-year limited warr<strong>an</strong>ty on compressor, coil <strong>an</strong>d 1 year on parts (<strong>Residential</strong>) ................................................... ✔ ✔ ✔• Extended warr<strong>an</strong>ties available ............................................................................................................................ ✔ ✔ ✔PHASED OUT PHASED OUT PHASED OUTTable SH-10-B — Optional AccessoriesAY28X079 ...................... Evaporator Defrost Control ............................................................................................. ✔ ✔ ✔BAYECMT001 ................ Extreme Condition Mounting Kit ..................................................................................... ✔ ✔ ✔BAYISLT101 .................. Rubber Isolators ............................................................................................................. ✔ ✔ ✔BAYLEGS002 ................ Snow Legs - Base <strong>an</strong>d Cap 6" High (Black) ................................................................... ✔ ✔ ✔BAYLEGS003 ................ 4" Extension (Black) ....................................................................................................... ✔ ✔ ✔BAYLOAM103 ................ Electronic Head Pressure Control .................................................................................. ✔ ✔ ✔BAYSDEN001 ................ Single Cylinder Compressor Enclosures ........................................................................ 2½-3 2½ —BAYSDEN002 ................ Two Cylinder Compressor Enclosures ........................................................................... 3½-5 3-4 —BAYSDEN003 ................ Small Scroll Compressor Enclosures ............................................................................. — — 2½-4BAYSDEN004 ................ Large Scroll Compressor Enclosures ............................................................................. 6 5 5BAYSEAC001 ................ Seacoast Kit ................................................................................................................... ✔ ✔ ✔TAYASCT501A12 ........ Anti-Short Cycle Timer ................................................................................................... ✔ ✔ ✔Table SH-10-C — Comfort ControlsTAYSENS100A ............. Outdoor Temp. Sensor (with case) ................................................................................TAYSTAT241 ................. M<strong>an</strong>ual 2 Stg Htg/1 Clg ..................................................................................................TAYSTAT250B .............. Outdoor Thermostat .......................................................................................................TAYSTAT300C ............. XT300C Prog.,7 Day,A/M,1Htg/1Clg ..............................................................................TAYSTAT340 ................. Prog., 5/2 Day, M<strong>an</strong>ual, 1 Htg/1 Clg ...............................................................................TAYSTAT350 ................. Prog., 5/2 Day, M<strong>an</strong>ual, 2 (Gas) Htg/1 Clg .....................................................................TAYSTAT370 ................. Electronic, 1Htg(Gas)/1Clg(Non Prog.) ..........................................................................TAYSTAT371 ................. Electronic, 1Htg(Elec)/1Clg(Non Prog.) ..........................................................................TAYSTAT380 ................. Electronic, 2 Htg (Gas) 1 Clg(Non Prog.) .......................................................................TCONT200A .................. Electronic, 1Htg/1Clg (Gas/Elec./Oil) .............................................................................TCONT401A .................. 2Heat/1Clg (Heat Pump/A/C) .........................................................................................TCONT402A .................. 3Heat/2Clg (Heat Pump/A/C) .........................................................................................TCONT600A .................. 1Heat/1Clg (Heat Pump/A/C) .........................................................................................TCONT602A .................. 2Heat/1Clg (Heat Pump/A/C) .........................................................................................TCONT800A .................. 2Heat/1Clg (Heat Pump/A/C) .........................................................................................TCONT802A .................. 3Heat/2Clg (Heat Pump/A/C) .........................................................................................TCONT803A .................. 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control ..........................................................1 Do not use with programmable thermostats2 Activated on Power Off.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.See Comfort Controls/Zone Sensors SectionSee Comfort Controls/Zone Sensors Section✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔Effective 1/1/06SH-10For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System Heat PumpsThree Phase – 7½ through 20 TonsTWA – 7½ through 20 Tons• Single refriger<strong>an</strong>t circuit on 7½ <strong>an</strong>d 10 tonsizes (<strong>Tr<strong>an</strong>e</strong> 3-D ® Scroll compressor)• Dual refriger<strong>an</strong>t circuits on 15 <strong>an</strong>d 20 tonsizes. (Two <strong>Tr<strong>an</strong>e</strong> 3-D ® Scroll compressors)• Service valves with pressure taps• Utilizes <strong>Tr<strong>an</strong>e</strong> compressor(s) for highreliability <strong>an</strong>d long life• Vertical upflow condenser discharge• Electronic time/temp. defrost control• Plate type aluminum fin/copper enh<strong>an</strong>cedtube condenser heat tr<strong>an</strong>sfer for highefficiency to reduce energy consumption• High/low pressure cut-out switches• Internal pressure relief valve• Single side service access for reducedmainten<strong>an</strong>ce cost• Factory installed refriger<strong>an</strong>t drier to increasereliability• Brazed refriger<strong>an</strong>t piping connections• Powder paint• Low ambient cooling to 50°F as shipped.• 5-year compressor warr<strong>an</strong>ty through 15tons, 1-year limited parts warr<strong>an</strong>ty• 1-year compressor warr<strong>an</strong>ty on20 ton unit, 1-year limited parts warr<strong>an</strong>tyTable SH-11-A— TWA Split System Heat Pump — Single CompressorFactory Nom. Cap. Uncrated Shipping Line SizeModel Installed Power Cooling Dimensions(in.) Mfg. Weight Sound Max OD ODNumber Option Supply (BTUH) H W L Pl<strong>an</strong>t (lbs.) Rating MCA Fuse Gas Liq.TWA090A300F — 208-230/3/60 91,000 39 34 41 SPR 390 8.8 34.5 50 1 3 /8 1/2TWA120A300F — 208-230/3/60 124,000 44 38 51 SPR 502 8.8 48.1 70 1 3 /8 1/2TWA090A400F — 460/3/60 91,000 39 34 41 SPR 390 8.8 18.1 25 1 3 /8TWA120A400F — 460/3/60 124,000 44 38 51 SPR 502 8.8 23.3 35 1 3 /8TWA090AW00F — 575/3/60 91,000 39 34 41 SPR 390 8.8 14.5 25 1 3 /8TWA120AW00F — 575/3/60 124,000 44 38 51 SPR 502 8.8 18.8 35 1 3 /81/21/21/21/2Table SH-11-B— TWA Split System Heat Pump — Dual CompressorFactory Nom. Cap. Uncrated Shipping Line SizeModel Installed Power Cooling Dimensions(in.) Mfg. Weight Sound Max OD ODNumber Option Supply (BTUH) H W L Pl<strong>an</strong>t (lbs.) Rating MCA Fuse Gas Liq.TWA180B300F — 208-230/3/60 182,000 38 34 88 SPR 816 8.8 62.7 80 1 3 /8 1/2TWA240B300F — 208-230/3/60 240,000 45 44 94 SPR 934 8.8 87.8 100 1 3 /8 1/2TWA180B400F — 460/3/60 182,000 38 34 88 SPR 816 8.8 32.9 45 1 3 /8TWA240B400F — 460/3/60 240,000 45 44 94 SPR 934 8.8 42.5 50 1 3 /81/21/2TWA180BW00F — 575/3/60 182,000 38 34 88 SPR 816 8.8 26.3 35 1 3 /8TWA240BW00F — 575/3/60 240,000 45 44 94 SPR 934 8.8 34.2 45 1 3 /8Table SH-11-A — Optional factory installed Black Epoxy Coil for corrosive resist<strong>an</strong>ce.Factory Nom. Cap. Uncrated Shipping Line SizeModel Installed Power Cooling Dimensions(in.) Mfg. Weight Sound Max OD ODNumber Option Supply (BTUH) H W L Pl<strong>an</strong>t (lbs.) Rating MCA Fuse Gas Liq.TWA090A30SF Epoxy Coil 208-230/3/60 91,000 39 34 41 SPR 390 8.8 34.5 50 1 3 /8 1/2TWA120A30SF Epoxy Coil 208-230/3/60 124,000 44 38 51 SPR 502 8.8 48.1 70 1 3 /8 1/21/21/2TWA090A40SF Epoxy Coil 460/3/60 91,000 39 34 41 SPR 390 8.8 18.1 25 1 3 /8TWA120A40SF Epoxy Coil 460/3/60 124,000 44 38 51 SPR 502 8.8 23.3 35 1 3 /81/21/2TWA090AW0SF Epoxy Coil 575/3/60 91,000 39 34 41 SPR 390 8.8 14.5 20 1 3 /8TWA120AW0SF Epoxy Coil 575/3/60 124,000 44 38 51 SPR 502 8.8 18.8 25 1 3 /8Table SH-11-B — Optional factory installed Black Epoxy Coil for corrosive resist<strong>an</strong>ce.Factory Nom. Cap. Uncrated Shipping Line SizeModel Installed Power Cooling Dimensions(in.) Mfg. Weight Sound Max OD ODNumber Option Supply (BTUH) H W L Pl<strong>an</strong>t (lbs.) Rating MCA Fuse Gas Liq.TWA180B30SF Epoxy Coil 208-230/3/60 182,000 38 34 88 SPR 816 8.8 62.7 80 1 3 /8 1/2TWA240B30SF Epoxy Coil 208-230/3/60 240,000 45 44 94 SPR 934 8.8 87.8 100 1 3 /8 1/21/21/2TWA180B40SF Epoxy Coil 460/3/60 182,000 38 34 88 SPR 816 8.8 32.9 45 1 3 /8TWA240B40SF Epoxy Coil 460/3/60 240,000 45 44 94 SPR 934 8.8 42.5 50 1 3 /81/21/2TWA180BW0SF Epoxy Coil 575/3/60 182,000 38 34 88 SPR 816 8.8 26.3 35 1 3 /8TWA240BW0SF Epoxy Coil 575/3/60 240,000 45 44 94 SPR 934 8.8 34.2 45 1 3 /81 Sound Rating shown is tested in accord<strong>an</strong>ce with ARI st<strong>an</strong>dard 270 or 370.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.SH-11 Effective 1/1/061/21/2


Split System Heat PumpsThree Phase – 7½ through 20 TonsTable SH-12-A — Optional AccessoriesModelNumber Description Used WithBAYISLT005A ................... Rubber-In-Shear Isolator ................................ TWA090, 120ABAYISLT009A ................... Rubber-In-Shear Isolator ................................ TWA180BBAYISLT010A ................... Rubber-In-Shear Isolator ................................ TWA240BBAYISLT023A ................... Steel Spring Isolator ....................................... TWA090, 120ABAYISLT024A ................... Steel Spring Isolator ....................................... TWA180BBAYISLT025A ................... Steel Spring Isolator ....................................... TWA240BBAYASCT00125 ............. Anti-Short-Cycle Timer ................................... All TWA ModelsBAYSTAT033A .................. ODT 45°F to -10°F .......................................... All TWA ModelsBAYGARD024A ................ Coil Guard Kit ................................................. TWA090ABAYGARD038A ................ Coil Guard Kit ................................................. TWA120ABAYGARD028A ................ Coil Guard Kit ................................................. TWA180BBAYGARD042A ................ Coil Guard Kit ................................................. TWA240BBAYLOAM015A1 ............ Head Pressure Control-575V ......................... TWA090W,TWA180BWBAYLOAMW22A1 ........... Head Pressure Control-575V ......................... TWA120AW,TWA240BWBAYLOAM326A13 ......... Head Pressure Control-230V ......................... TWA090A3BAYLOAM327A13 ......... Head Pressure Control-230V ......................... TWA120A3BAYLOAM328A13 ......... Low Ambient Kit-230V .................................... TWA240B3BAYLOAM329A13 ......... Low Ambient Kit-230V .................................... TWA180B3BAYLOAM425A13 ......... Head Pressure Control-460V ......................... TWA090A4BAYLOAM426A13 ......... Head Pressure Control-460V ......................... TWA120A4BAYLOAM427A13 ......... Low Ambient Kit-460V .................................... TWA240B4BAYLOAM428A13 ......... Low Ambient Kit-460V .................................... TWA180B4BAYLOAM429B67 ......... Low Ambient F<strong>an</strong> Cycle Control ..................... TWA090-240A,B,CBAYRLAY0022 ................ Time Delay Relay ........................................... TWA180-240B, TWA090-120ATAYSTAT250A .................. Outdoor Thermostat ........................................ All Heat Pump ModelsTable SH-12-B — Comfort ControlsModelNumber Description Used WithBAY28X138A .................... 2 Htg/1 Clg Automatic Ch<strong>an</strong>geover ................ TWA090-120ABAY28X153A .................... 3 Htg/2 Clg Automatic Ch<strong>an</strong>geover ................ TWA180-240BBAY28X1902 ................. Locking Thermostat Cover .............................. All Room ThermostatsBAYBASE007A ................ 3 Htg/2 Clg Subbase ....................................... BAYSTAT040BBAYSENS033A ................ Remote Wall Sensor ....................................... BAYSTAT040BBAYSENS034A ................ Remote Duct Sensor ...................................... BAYSTAT040BBAYSTAT040B4 ............. Programmable Thermostat ............................. TWA090-240BBAYSTAT239 ................... 2 Htg/1 Clg M<strong>an</strong>ual Ch<strong>an</strong>geover .................... TWA090-120ATAYSENS100A ................ Outdoor Temp. Sensor (With Case) ............... TAYSTAT500C,575TAYSTAT500C ................. XT 500C Prog., 7 Day, M<strong>an</strong>/Auto ................... All Heat Pump ModelsTAYSTAT570 ................... Electronic, 2 Htg/1 Clg (Non Prog.) ................ All Heat Pump Models1 Qu<strong>an</strong>tity 1 required for each f<strong>an</strong>. (TWA180B, TWA240B)2 Do not use with programmable thermostats.3 Requires the use of BAYRLAY005A Interlock Kit.4 Requires the use of BAYBASE007A.5 Activated on Power ON.6 Option is compatible for units with electric mech<strong>an</strong>ical controls unit.7 Kit mounts external to the outdoor unit <strong>an</strong>d operates by sensing ambient <strong>an</strong>d liquid line temperatures.Effective 1/1/06SH-12For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


TRANE 2TEH AIR HANDLERTRANETEH AH<strong>Tr<strong>an</strong>e</strong> Profit-abilitySell-abilitySuperior perform<strong>an</strong>ce <strong>an</strong>d appear<strong>an</strong>ce4-speed f<strong>an</strong> motorAir-Tite TMcabinetPrecision engineeringSound reductionMatched systemsInstall-ability6-way convertibilityTonnage 1.5 to 5Recessed screwsExternal drain connectionsService-abilityEasy-access control boxQuick filter ch<strong>an</strong>ge with st<strong>an</strong>dard filtersExternal refriger<strong>an</strong>t componentsEasy coil cle<strong>an</strong>ingPerform<strong>an</strong>ce-abilityHigh efficiency400 CFM/ton nominal airflowThermostatic exp<strong>an</strong>sion valveRely-abilityBest reliabilityQuiet internal check valveQUIET AND HIGHLY EFFICIENT. DESIGNED WITH YOUR CUSTOMER IN MIND.The 2TEH air h<strong>an</strong>dler is the right choice for customerslooking to maximize comfort <strong>an</strong>d efficiency. Ideal for newhome builders or as a replacement unit for discerningcustomers, the 2TEH has a 4-speed indoor blowerdistributing 400 CFM/ton nominal air flow for even,consistent comfort every month of the year. The 2TEHTRANE LIMITED WARRANTY5-year functional partsis among the quietest units we make. It has a highefficiency blower motor <strong>an</strong>d our unique Vortica TM blowerdesign—all in <strong>an</strong> attractive, smaller-sized package thatmeets or beats the competition for reliability. And thatshould yield some reliable profits for you.Reliable perform<strong>an</strong>ceBetter indoor airComfort controlEnh<strong>an</strong>ced comfortEfficient operationPrecision engineering, designinnovation <strong>an</strong>d rigorous testing forreliable, long-lasting perform<strong>an</strong>ce<strong>an</strong>d durability.Add a TRANE Cle<strong>an</strong>Effects TM aircle<strong>an</strong>er <strong>an</strong>d remove up to 99.98%of airborne allergens from thefiltered air for a cle<strong>an</strong>er, morecomfortable home.Give your customers bettercomfort control with a <strong>Tr<strong>an</strong>e</strong> digitalor programmable thermostat.Delivers quiet, even, consistentcomfort all year round.Increased efficiencymay subst<strong>an</strong>tially lowercustomers’ utility costs.


6TRANE 2TEH AIR HANDLERTRANETEH AHFeatures <strong>an</strong>d components may vary by model<strong>an</strong>d are shown for illustration purposes only.510789311421123456High efficiency 4-speed indoorblower motorProvides airflow flexibility to closely match heating<strong>an</strong>d cooling requirements. Delivers exceptional airflow <strong>an</strong>d efficiency.Easy-access control boxLocated behind one easy-to-remove p<strong>an</strong>el for fastinstallation <strong>an</strong>d service.“No Leak” base p<strong>an</strong>Rust-resist<strong>an</strong>t, polycarbonate drain p<strong>an</strong>. Fullysloped to put <strong>an</strong> end to st<strong>an</strong>ding water.Extra-large coil surfaceEnh<strong>an</strong>ces heat tr<strong>an</strong>sfer, provides greater efficiency<strong>an</strong>d more heating <strong>an</strong>d cooling capacity.Recessed screwsWill not snag on walls or door facings duringinstallation.Corrosion-resist<strong>an</strong>t finishCovers all p<strong>an</strong>els uniformly to resist corrosion.7891011Insulated cabinetHeavy steel <strong>an</strong>d insulation protects from heating<strong>an</strong>d cooling losses, lowers sound levels, <strong>an</strong>d iseasy to cle<strong>an</strong>.Fully gasketed doorsReduces air leaks to improve efficiency, <strong>an</strong>ddecreases overall sound.Easy-access filter doorsSt<strong>an</strong>dard off-the-shelf filters located behind oneeasy-to-remove door for quick <strong>an</strong>d convenientfilter ch<strong>an</strong>ge.External refriger<strong>an</strong>t drain connectionsProvide for faster installation <strong>an</strong>d service.Vortica TM adv<strong>an</strong>ced air flow systemImproves airflow while reducing energy use <strong>an</strong>doperating sound. Durable composite material willnot crack, corrode or rust.2TEH AIR HANDLER (R-22 Refriger<strong>an</strong>t)NominalUncratedPower Cap. Clg. Ref. Flow F<strong>an</strong> D imensions (in.)Model Supply (BTUH) Con Control Speed H W D2TEH3F18A1000A 200/230/1/60 18,000 BZ TXV-NB 4 43 21.5 212TEH3F24A1000A 200/230/1/60 24,000 BZ TXV-NB 4 43 21.5 212TEH3F30A1000A 200/230/1/60 30,000 BZ TXV-NB 4 45 21.5 212TEH3F36A1000A 200/230/1/60 36,000 BZ TXV-NB 4 45 21.5 212TEH3F42A1000A 200/230/1/60 42,000 BZ TXV-NB 4 51.75 23.5 212TEH3F48A1000A 200/230/1/60 48,000 BZ TXV-NB 4 57.9 23.5 212TEH3F60A1000A 200/230/1/60 60,000 BZ TXV-NB 4 57.9 23.5 21As part of our continuous product improvement, <strong>Tr<strong>an</strong>e</strong> reserves the right to ch<strong>an</strong>ge specifications <strong>an</strong>d design without notice.Warr<strong>an</strong>ties generate additional income.<strong>Tr<strong>an</strong>e</strong> extended warr<strong>an</strong>ties create additional income. Selling extendedwarr<strong>an</strong>ties is <strong>an</strong>other way to protect your customers <strong>an</strong>d generatefuture business.It all adds up to a stellar reputation.We know that when you recommend our products to customers, youare placing your livelihood <strong>an</strong>d reputation in our h<strong>an</strong>ds. We appreciateyour trust in us, <strong>an</strong>d your dedication to delivering <strong>Tr<strong>an</strong>e</strong> technology <strong>an</strong>dinnovation to your customers to make their homes better places forliving. You are the reason we c<strong>an</strong> say, “expect more from <strong>Tr<strong>an</strong>e</strong>.”tr<strong>an</strong>e.com© 2005 TRANE ® a business of Americ<strong>an</strong> St<strong>an</strong>dard Comp<strong>an</strong>ies. All rights reserved. Pub. No. 2TEHAH-01 11/05


Air H<strong>an</strong>dler ConvertibilityOne Unit – 4 ApplicationsConversion 1 – 4Easy Conversion to Opposite Side AccessConversion 5 – 6Horizontal Right(as shipped)Refriger<strong>an</strong>t connectors1 Unit is shipped asHorizontal rightPrimary CondensateAirflowAirflowHorizontal Drain P<strong>an</strong>Coil SupportsPrimaryCondensateVertical Upflow(as shipped)One-Step ConversionSt<strong>an</strong>d unit on endAirflow2 Pull coil out <strong>an</strong>drotate the coil 180°AirflowHorizontal LeftRotate Coil3 Slide coil back in onsupports <strong>an</strong>d roll unit 180°(So primary condensate is down)AirflowAirflowVertical DownflowOne-Step Conversionfrom Horizontal leftSix ConversionApplications1. Horizontal Right –Front Access2. Vertical Upflow3. Horizontal Left –Front Access4. Vertical Downflow5. Horizontal Right –Rear Access6. Horizontal Left –Rear AccessAirflowPrimary Condensate4 Note connections<strong>an</strong>d access are nowon back side of unitPrimaryCondensateAirflowFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.AH-1 Effective 1/1/06


"Air-Tite TM "Features <strong>an</strong>d Benefits1 Duct Fl<strong>an</strong>ge – Allows flush fit for 3/4", 1" or 1 1/2" duct insulation2 Liner/Fl<strong>an</strong>ge Seal – Exclusive Duct Fl<strong>an</strong>ge ThermalBreak/Seal <strong>an</strong>d double wall construction to reducecabinet loss <strong>an</strong>d sweating.3 1" Foil Faced Insulation – Thicker foil faced insulationfor reduced cabinet loss, sweating <strong>an</strong>d lower power bills.4 Enclosed Control Box – Totally enclosed control boxwith tr<strong>an</strong>sformer inside to improve component life, unitdurability <strong>an</strong>d reliability.5 Corrosion Resist<strong>an</strong>t Screws – Exclusive “Weatherguard TM ”coated screws to maintain the quality appear<strong>an</strong>ce of theunit for the life of the product.6 Coupling P<strong>an</strong>el Insulation – Exclusive “No Burn” refriger<strong>an</strong>tcoupling p<strong>an</strong>el with thicker insulation for reduced heat loss.7 Filter Door Seal – Improved door seal for reduced air infiltration,heat tr<strong>an</strong>sfer, <strong>an</strong>d lower power bills.8 Filter Door – "Filter" is stamped on the p<strong>an</strong>el, <strong>an</strong>d includestwo captive screws with easy grip knobs.9 Insulation on Center Bar – Exclusive center bar insulationfor reduced cabinet loss, sweating <strong>an</strong>d lower power bills.0 Door Gasket – Exclusive formed gasket (similar to car doorgasket) to reduce air infiltration <strong>an</strong>d heat tr<strong>an</strong>sfer <strong>an</strong>d lowerpower bills.q Air-Tite TM Circuit Breaker Door – Easy access to breakerswith positive air seal.The SEER test for system efficiency places the air h<strong>an</strong>dler inthe ambient return air stream (80°F). If your air h<strong>an</strong>dler is tobe in <strong>an</strong> unconditioned/severe climatic location, you shouldconsider the adv<strong>an</strong>tages of the “Air-Tite TM ” model air h<strong>an</strong>dler.Effective 1/1/06AH-2For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System Air H<strong>an</strong>dlersSingle Phase — 1½ through 5 Tons1 1 /2 through 5 TonsTWE-E (R-22) & 4TEE (R-410A)Convertible Air H<strong>an</strong>dlers• Ships for vertical upflow <strong>an</strong>d horizontal rightapplications from factory• Six-way convertibility-horizontal (left & right);front & rear access; upflow, downflow• Electrical, refriger<strong>an</strong>t, condensate & bloweraccess convertible to either side• Compact 21" depth for easy installation• Variable speed Direct drive ECM motor• Enh<strong>an</strong>ced Comfort-R TM dehumidificationstart-up• Soft start - cycle-on speed is ramped upgradually to reduce sound <strong>an</strong>d draft• 200/230 volt primary & 24 volt, 75 VAsecondary tr<strong>an</strong>sformer• R 4.2-1" foil face insulated cabinet• Corrosion resist<strong>an</strong>t galv<strong>an</strong>ized metal withattractive finish• Versatile duct fl<strong>an</strong>ge - allows flush fit 3/4",1", or 1.5" duct insulation• Low voltage terminal board• External brazed refriger<strong>an</strong>t connections• Filter p<strong>an</strong>el stamped with word "filter"• Filter door seal• Exclusive duct fl<strong>an</strong>ge thermal break/seal• Check valve for heat pump application• IAQ (Indoor Air Quality) sloped/free drainingp<strong>an</strong>, no st<strong>an</strong>ding water• Non-bleed exp<strong>an</strong>sion valve refriger<strong>an</strong>tcontrol• Internally enh<strong>an</strong>ced finned coil tubing• Access to heater circuit breakers pull/disconnects• Polarized plugs for making motor <strong>an</strong>dtr<strong>an</strong>sformer electrical connections from airh<strong>an</strong>dler control box to electric heaters• Primary <strong>an</strong>d secondary drain connections• Built-in indoor f<strong>an</strong> delay function forincreased efficiency• TWE air h<strong>an</strong>dlers are approved for modularor m<strong>an</strong>ufactured homes.• Energy saving continuous f<strong>an</strong>• Enh<strong>an</strong>ced cooling/heating control Air Tite TM• 031E airflow selectable for 1-1/2 – 3 tonO.D. unit• 037E airflow selectable for 2 – 3-1/2 tonO.D. unit• 040E airflow selectable for 2 – 3-1/2 tonO.D. unit• 049E airflow selectable for 3 – 5 ton O.D.unit• 065E airflow selectable for 3-1/2 – 5 tonO.D. unit• 5 year limited parts residential warr<strong>an</strong>ty• 1 year limited parts commercial warr<strong>an</strong>ty• Optional extended warr<strong>an</strong>tiesTable AH-3-A — R-22 Convertible, Variable Speed with Comfort-R TM Enh<strong>an</strong>ced Mode Option (200/230/1/60)CoolingUnit Capacity Metering F<strong>an</strong> Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) Device Speed H x W x D Weight (Ibs.) Opening12Opening1 Sizes Gas LiquidTWE031E13FB 31,000 TXV-NB Variable 43x21.5x 21 134 19.22x12.02 or 18.22x 11.02 19.5x18.07 20x20x1 ¾ 5 /16TWE037E13FB 37,000 TXV-NB Variable 45x23.5x21 142 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7 /8 3/8TWE040E13FB 40,000 TXV-NB Variable 51.75x26x21 174 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 7 /8 3/8TWE049E13FB 49,000 TXV-NB Variable 57.90x26x21 188 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 1 1 /8 3/8TWE065E13FB3 65,000 TXV-NB Variable 62.75x26x21 218 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 1 1 /8 3/8Table AH-3-B — R-22 Convertible, Dual Circuit, Variable Speed with Comfort-R TM Enh<strong>an</strong>ced Mode Option (200/230/1/60)TWE062E13FB3 65,000 TXV-NB(2) Variable 63x26x21 218 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 ¾ 3 /8Table AH-3-C —R-410A Variable Speed Air-Tite (200/230/1/60)4TEE3F31A1000A 31,000 TXV-NB Variable 43x21.5x21 134 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3 /44TEE3F37A1000A 37,000 TXV-NB Variable 45x23.5x21 142 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 3 /44TEE3F40A1000A 40,000 TXV-NB Variable 51.75x26x21 174 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 3 /44TEE3F49A1000A 49,000 TXV-NB Variable 57.90x26x21 188 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 7 /84TEE3F65A1000A3 65,000 TXV-NB Variable 62.75x26x21 218 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 7 /85/163/83/83/83/8Table AH-3-D —R-410A Convertible, Dual Circuit, Variable Speed with Comfort-R Enh<strong>an</strong>ced Mode Option (200/230/1/60)4TEE3F62A1000A3 65,000 TXV-NB(2) Variable 63x26x21 218 23.72x12.02 or 22.72x11.02 24x18.22 20x25x1 ¾ 3 /8Table AH-3-E – AccessoriesModel Number Description Used WithAY28X079 .................................... Evaporator Defrost Control Kit ...................... All Cooling ModelsAY28X084 .................................... Evaporator Defrost Control Kit ...................... All Heat Pump ModelsBAY99X1235 ............................... Knockout Cover Plate* ................................... TWE031E-065E, 4TEE3F31A-65ABAYSPEK140B ............................. Single Power Entry Kit .................................... BAYHTR1415BRKB, 1419BRKBTAYBASE100 ............................... Downflow Subbase ........................................ TWE037E, 4TEE3F37ATAYBASE101 ............................... Downflow Subbase ........................................ TWE031E, 4TEE3F31ATAYBASE102 ............................... Downflow Subbase ........................................ TWE040E-065E, 4TEE3F40A-65ATAYPLNM1004 ........................... Pedestal Plenum Upflow ................................ TWE031E-037E, 4TEE3F31A-37ATAYPLNM101............................... Pedestal Plenum Upflow ................................ TWE040E-065E, 4TEE3F40A-65A1 Actual opening does not include fl<strong>an</strong>ge.2 Adjustable duct fl<strong>an</strong>ge allows for a flush fit with1 1 /2 inch insulation or 3 /4 inch or 1 inch insulation.3 Two (2) piece cabinetFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.4 4TEE3F31A-center on plenum for 2" difference in width.5 Minimum order 1 unit ( 1 unit = 50 pieces).* Required if no electric heat is used.See Heater Tables on Pages AH-9AH-3 Effective 1/1/06


Split System Air H<strong>an</strong>dlersSingle Phase — 1½ through 5 Tons1 1 /2 through 5 TonsConvertible High EfficiencyAir H<strong>an</strong>dlers• 13.0 - 14.0 SEER• High Efficiency direct drive motor• Ships for vertical upflow <strong>an</strong>d horizontal rightapplications from factory• Six- way convertibility-horizontal (left &right) upflow, downflow• “1-m<strong>an</strong>” installation opportunity• Electrical, refriger<strong>an</strong>t, condensate & bloweraccess convertible to either side• Compact 21" depth for easyinstallation• Corrosion resist<strong>an</strong>t galv<strong>an</strong>ized metal withattractive finish• Superior humidity perform<strong>an</strong>ce• Enh<strong>an</strong>ced internally finned coil tubes• Versatile duct fl<strong>an</strong>ge - allows flush fit 3/4",1", or 1.5" duct insulation• Filter p<strong>an</strong>el stamped with word "filter"• 200/230 volt primary & 24 volt secondarytr<strong>an</strong>sformer• Low voltage wire nut connections• Insulated cabinet• External access to heater electricaldisconnects• Polarized plugs for making electricalconnections from air h<strong>an</strong>dler control box toheaters• Approved for modular or m<strong>an</strong>ufacturedhomes• Optional extended warr<strong>an</strong>tiesTable AH-4-A — Horizontal with vertical convertibility (200/230/1/60)CoolingUnit Capacity Metering F<strong>an</strong> Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) Device Speed H x W x D Weight (Ibs.) Opening12Opening1 Sizes Gas Liquid2TEH3F18A1000A 18,000 TXV-NB 4 43x21.5x 21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x 5/82TEH3F24A1000A 24,000 TXV-NB 4 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3 /42TEH3F30A1000A 30,000 TXV-NB 4 45x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3 /42TEH3F36A1000A 36,000 TXV-NB 4 45x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 7 /82TEH3F42A1000A 42,000 TXV-NB 4 51.8x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7 /82TEH3F48A1000A* 48,000 TXV-NB 4 57.9x23.5x21 188 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 1 1 /82TEH3F60A1000A* 60,000 TXV-NB 4 57.9x23.5x21 193 21.22x12.02 or 20.22x11.02 21.5x18.07 20x22x1 1 1 /81/45/165/163/83/83/83/8Table AH-4-B – AccessoriesModel Number Description Used WithAY28X079 ..................................... Evaporator Defrost Control Kit ........................ All Cooling ModelsBAYSPEK140B ............................. Single Power Entry Kit .................................... BAYHTR1315BRKA, BAYHTR1319BRKATAYPLNM1001 ............................ Pedestal Plenum Upflow ................................ 2TEH3F18-60A1000ATAYBASE101 ............................... Downflow Subbase ......................................... 2TEH3F18-36A1000ATAYBASE100 ............................... Downflow Subbase ......................................... 2TEH3F42-60A1000A1 For TEH018,024,030, center on plenum for 2" difference in width.* Two piece cabinetBAYHTR1300 ONLYSee Heater Tables on Pages AH-82TEH3F18 & 24B will accommodate 10 & 15 kW Strip Heat - (BAYHTR1300 series only) in March, 2006.Effective 1/1/06AH-4For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System Air H<strong>an</strong>dlersSingle Phase — 1½ through 5 Tons1 1 /2 through 5 Tons2/4TECConvertible Air H<strong>an</strong>dlers• 13.0 SEER• Ships for vertical upflow <strong>an</strong>d horizontal rightapplications from factory• Six- way convertibility-horizontal (left &right); front & rear access; upflow,downflow• “1-m<strong>an</strong>” installation opportunity• Electrical, refriger<strong>an</strong>t, condensate & bloweraccess convertible to either side• Compact 21" depth for easyinstallation• Corrosion resist<strong>an</strong>t galv<strong>an</strong>ized metal withattractive finish• Superior humidity perform<strong>an</strong>ce• Enh<strong>an</strong>ced internally finned coil tubes• Direct drive motor• Versatile duct fl<strong>an</strong>ge - allows flush fit 3/4",1", or 1.5" duct insulation• Filter p<strong>an</strong>el stamped with word "filter"• 200/230 volt primary & 24 volt secondarytr<strong>an</strong>sformer• Low voltage wire nut connections• Insulated cabinet• External access to heater electricaldisconnects• Polarized plugs for making electricalconnections from air h<strong>an</strong>dler control box toheaters• Approved for modular or m<strong>an</strong>ufacturedhomes• Optional extended warr<strong>an</strong>tiesTable AH-5-A — Horizontal with vertical convertibility (200/230/1/60)CoolingUnit Capacity Metering F<strong>an</strong> Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) Device Speed H x W x D Weight (Ibs.) Opening12Opening1 Sizes Gas Liquid2TEC3F18A1000A 18,000 TXV-NB 3 43x21.5x21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 5 /82TEC3F24A1000A 24,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3 /42TEC3F30A1000A 30,000 TXV-NB 3 45x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3 /42TEC3F36A1000A 36,000 TXV-NB 3 45x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 7 /82TEC3F42A1000A 42,000 TXV-NB 3 51.8x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7 /82TEC3F48A1000A* 48,000 TXV-NB 3 57.9x23.5x21 188 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 1 1 /82TEC3F55A1000A* 60,000 TXV-NB 3 57.9x26x21 193 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 1 1 /82TEC3F60A1000A* 60,000 TXV-NB 4 57.9x23.5x21 193 21.22x12.02 or 20.22x11.02 21.5x18.07 20x22x1 1 1 /84TEC3F18A1000A 18,000 TXV-NB 3 43x21.5x21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 1 /24TEC3F24A1000A 24,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 5 /84TEC3F30A1000A 30,000 TXV-NB 3 45x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3 /44TEC3F36A1000A 36,000 TXV-NB 3 45x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3 /44TEC3F42A1000A 42,000 TXV-NB 3 51.8x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 3 /44TEC3F48A1000A* 48,000 TXV-NB 3 57.9x23.5x21 188 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7 /84TEC3F55A1000A* 60,000 TXV-NB 3 57.9x26x21 193 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 7 /84TEC3F60A1000A* 60,000 TXV-NB 4 57.9x23.5x21 193 21.22x12.02 or 20.22x11.02 21.5x18.07 20x22x1 7 /81/45/165/163/83/83/83/83/81/45/165/163/83/83/83/83/8Table AH-5-B – AccessoriesModel Number Description Used WithBAYSPEK140B ............................. Single Power Entry Kit .................................... BAYHTR1415BRKB, BAYHTR1419BRKBTAYPLNM1001 ............................ Pedestal Plenum Upflow ................................ 2/4TEC3F18-60A1000ATAYBASE101 ............................... Downflow Subbase ......................................... 2/4TEC3F18-36A1000ATAYBASE100 ............................... Downflow Subbase ......................................... 2/4TEC3F42-60A1000ABAY99X123 .................................. Knockout Cover Plate ..................................... 2/4TEC3F18-60A1000A1 For TEC018,024,030, center on plenum for 2" difference in width.* Two piece cabinetSee Heater Tables on Pages AH-9For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.AH-5 Effective 1/1/06


Split System Air H<strong>an</strong>dlersSingle Phase — 1½ through 4 Tons1 1 /2 through 4 Tons• Exclusive easy to cle<strong>an</strong> coil <strong>an</strong>d drain p<strong>an</strong>• Convertible upflow to horizontal left (notools required) (matches installed units)• Designed to use "off the shelf"st<strong>an</strong>dard size replaceable fiberglassfilters• Easy to remove filters <strong>an</strong>d blowers for easycle<strong>an</strong>ing <strong>an</strong>d replacement• Exp<strong>an</strong>ded application fit with narrowcabinet profile• Easy access electrical controls <strong>an</strong>d hookup• Attractive enamel finish• R 4.2 - 1" insulation• Versatile duct fl<strong>an</strong>ge - allows flush fit with3/4", 1" or 1.5" duct insulation• Air-Tite cabinet - low leak by design• IAQ (Indoor Air Quality) sloped/freedraining p<strong>an</strong> (no st<strong>an</strong>ding water)• Durable, glass-filled composite - Never rust,no leak drain p<strong>an</strong>• Maximum depth 21" - fits pull-downstaircase• Exclusive maximum width 23.5" - fits 2-ft.wide door all sizes• External access to electrical disconnects• Direct drive motor• Filter p<strong>an</strong>el stamped with word "filter"• Exp<strong>an</strong>sion valve (non-bleed TXV)st<strong>an</strong>dard on all models• Polarized plugs for easy hook-up to electricheaters• 200/230 volt primary <strong>an</strong>d 24 volt secondarytr<strong>an</strong>sformer• Approved for modular or m<strong>an</strong>ufacturedhomes• Optional extended warr<strong>an</strong>tiesTable AH-6-A — Vertical Upflow <strong>an</strong>d Horizontal Left (200/230/1/60)CoolingUnit Capacity Metering F<strong>an</strong> Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) Device Speed H x W x D Weight (Ibs.) Opening12Opening1 Sizes Gas Liquid2TGB3F18A1000A 18,000 TXV-NB 3 45.7x18x21 124 16x12.12 or 15x11.12 16x18.22 16x20x1 5 /82TGB3F25A1000A 24,000 TXV-NB 3 45.7x18x21 124 16x12.12 or 15x11.12 16x18.22 16x20x1 3 /42TGB3F30A1000A 30,000 TXV-NB 3 52x18x21 135 16x12.12 or 15x11.12 16x18.22 16x20x1 3 /42TGB3F36A1000A 36,000 TXV-NB 3 52x18x21 135 16x12.12 or 15x11.12 16x18.22 16x20x1 7 /82TGB3F42A1000A 42,000 TXV-NB 3 48.3x23.5x21 147 21.5x12.12 or 20.5x11.12 21.5x18.22 20x20x1 7 /82TGB3F48A1000A 48,000 TXV-NB 3 57.3x23.5x21 172 21.5x12.12 or 20.5x11.12 21.5x18.22 20x20x1 7 /81/45/165/163/83/83/8Table AH-6-B – AccessoriesModel Number Description Used WithBAYSPEK140B ............................. Single Power Entry Kit .................................... BAYHTR1415BRKB, BAYHTR1419BRKBSee Heater Tables on Pages AH-9Effective 1/1/06AH-6For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System Air H<strong>an</strong>dlersSingle Phase — 1½ through 2½ Tons1 1 /2 through 2 1 /2 Tons• Shipped in vertical upflow, bottom returnwith front access & convertible to verticalupflow front return• Variable speed ECM motor(2/4TFE Models)• Enh<strong>an</strong>ced Comfort-R (2/4TFE Models)• Soft start - f<strong>an</strong> speed is ramped upgradually to reduce sound <strong>an</strong>d draft(2/4TFE Models)• Low voltage terminal board(2/4TFE Models)• Air-Tite cabinet - low leakage by design• Attractive enamel finish• R 4.2-1” insulation• Exclusive easy cle<strong>an</strong> coil <strong>an</strong>d drain p<strong>an</strong>• Easy to remove filters <strong>an</strong>d blowers for easycle<strong>an</strong>ing <strong>an</strong>d replacement• Filter rack with throw away filter• Easy access electrical controls <strong>an</strong>dhook-up• 200/230 volt primary <strong>an</strong>d 24 volt secondarytr<strong>an</strong>sformer• Multi-speed blower (2TFB Models)• Direct drive motor (2TFB Models)• Factory installed electric heaters• Factory installed service disconnect• Internally enh<strong>an</strong>ced finned coil tubing• Primary <strong>an</strong>d secondary drain connections• Approved for modular or m<strong>an</strong>ufacturedhomes• Optional extended warr<strong>an</strong>ties• Five year limited parts warr<strong>an</strong>tyTable AH-7-A — Vertical Upflow <strong>an</strong>d Horizontal Left (200/230/1/60)CoolingUnit Capacity Metering F<strong>an</strong> Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) Device Speed H x W x D Weight (Ibs.) Opening12Opening1 Sizes Gas Liquid2TFB3F18B1D05A 18,000 TXV-NB 2 37x22x19.4 115 14x10.12 17.22x20 18x20x1 5/82TFB3F18B1D08A 18,000 TXV-NB 2 37x22x19.4 115 14x10.12 17.22x20 18x20x1 5/82TFB3F18B1D10A 18,000 TXV-NB 2 37x22x19.4 115 14x10.12 17.22x20 18x20x1 5/82TFB3F24B1D05A 24,000 TXV-NB 2 39x22x19.4 120 14x10.12 17.22x20 18x20x1 3/42TFB3F24B1D08A 24,000 TXV-NB 2 39x22x19.4 120 14x10.12 17.22x20 18x20x1 3/42TFB3F24B1D10A 24,000 TXV-NB 2 39x22x19.4 120 14x10.12 17.22x20 18x20x1 3/42TFB3F30B1D05A 30,000 TXV-NB 2 39x22x19.4 120 14x10.12 17.22x20 18x20x1 3/42TFB3F30B1D08A 30,000 TXV-NB 2 39x22x19.4 120 14x10.12 17.22x20 18x20x1 3/42TFB3F30B1D10A 30,000 TXV-NB 2 39x22x19.4 120 14x10.12 17.22x20 18x20x1 3/41/41/41/45/165/165/165/165/165/16Table AH-7-B — Variable Speed R-22 (200/230/1/60)CoolingUnit Capacity Metering F<strong>an</strong> Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) Device Speed H x W x D Weight (Ibs.) Opening12Opening1 Sizes Gas Liquid2TFE3F25B1D05A 25,000 TXV-NB Var 39x22x19.4 120 14x10.12 17.22x20 18x20x1 3/42TFE3F25B1D08A 25,000 TXV-NB Var 39x22x19.4 120 14x10.12 17.22x20 18x20x1 3/42TFE3F25B1D10A 25,000 TXV-NB Var 39x22x19.4 120 14x10.12 17.22x20 18x20x1 3/45/165/165/16Table AH-7-C — Variable Speed R-410A (200/230/1/60)CoolingUnit Capacity Metering F<strong>an</strong> Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) Device Speed H x W x D Weight (Ibs.) Opening12Opening1 Sizes Gas Liquid4TFE3F25B1D05A 25,000 TXV-NB Var 39x22x19.4 120 14x10.12 17.22x20 18x20x1 5/84TFE3F25B1D08A 25,000 TXV-NB Var 39x22x19.4 120 14x10.12 17.22x20 18x20x1 5/84TFE3F25B1D10A 25,000 TXV-NB Var 39x22x19.4 120 14x10.12 17.22x20 18x20x1 5/8* Heater kW is based on 240 volt rating.1/41/41/4For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.AH-7 Effective 1/1/06


Heaters for Split System <strong>an</strong>dConvertible Air H<strong>an</strong>dlersTable AH-8-A Heaters for 2TEH onlyHeater Capacity Capacity Heater Amps ContainsModel @ 240 Volts @ 208 Volts Rated Control per Circuit CircuitNumber kW BTUH kW BTUH Voltage Stages 208 Volts 240Volt BreakersBAYHTR1305000 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 NoBAYHTR1305BRK 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 YesBAYHTR1305PDC 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 NoBAYHTR1308000 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 NoBAYHTR1308BRK 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 YesBAYHTR1308PDC 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 NoBAYHTR1310000 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 NoBAYHTR1310BRK 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 YesBAYHTR1310PDC 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 NoBAYHTR1315BRK 15.36 52,400 11.53 39,300 208/240/1/60 2 34.6/20.812 40/241 YesBAYHTR1319BRK 19.20 65,500 14.42 44,200 208/240/1/60 2 27.8/41.612 32/481 YesThree PhaseBAYHTR3310000 9.60 32,800 7.20 24,600 208/240/3/60 1 30 34.6 NoBAYHTR3315000 15.36 52,400 11.53 39,300 208/240/3/60 1 33 38.2 No1 Circuit 1/Circuit 22 Heater c<strong>an</strong> be converted to single circuit power entry by usingBAYSPEK140B. This kit allows a single power circuit to be used with electricheaters that contain two (2) circuit breakers.Table AH-9-B Heater Matrix for 2TEH onlyMINIMUM HEATING AIRFLOW CFM - HEATER MATRIXAIR HANDLERHEATER MODEL NUMBERMODEL NUMBER BAYHTR1305+++ BAYHTR1308+++ BAYHTR1310+++ BAYHTR3310000 BAYHTR1315BRK BAYHTR3315000 BAYHTR1319BRK4.80kW 7.68kW 9.60kW 9.60kW 15.36kW 15.36kW 19.20kWNUMBER OF 1 2 2 2 3 3 4HEATER RACKSNUMBER OF 1 1 1 1 2 1 2CIRCUITS2TEH3F18A100A L/MH L/MH N/A N/A N/A N/A N/A2TEH3F24A100A L/ML L/PS N/A N/A N/A N/A N/A2TEH3F30A100A L/L L/ML ML/H ML/H N/A N/A N/A2TEH3F36A100A L/L L/PS ML/PS ML/PS ML/H ML/H ML/H2TEH3F42A100A ML/ML ML/PS ML/MH ML/MH ML/H ML/H ML/H2TEH3F48A100A ML/ML ML/ML ML/PS ML/PS ML/H ML/H ML/H2TEH3F60A100A ML/ML ML/ML ML/ML ML/ML ML/MH ML/MH ML/HCooling/Heat Pump Air FlowPS = Position sensitive. Minimum speed tap varies based on air h<strong>an</strong>dler installation position. See air h<strong>an</strong>dler nameplate or product data.L = LowML = Medium-LowMH = Medium-HighH = High+++ = 000 (pigtails), PCD (contains pull disconnect), BRK (contains circuit disconnects)BAYSPEK140B to be used with BAYHTR1315BRKA, BAYHTR1319BRKA.CAUTION: Any power supply <strong>an</strong>d/or combination power supply, circuit or circuits must bewired <strong>an</strong>d protected in accord<strong>an</strong>ce with local electrical codes.Effective 1/1/06AH-8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Heaters for Split System <strong>an</strong>dConvertible Air H<strong>an</strong>dlersTable AH-9-B Heaters For TWE-C/D; TWE-P;TWE-E;TWG; 4TEE;2/4TEP, 2/4 TEC, 2TGBHeater Capacity Capacity Heater Amps ContainsModel @ 240 Volts @ 208 Volts Rated Control per Circuit CircuitNumber kW BTUH kW BTUH Voltage Stages 208 Volts 240Volt BreakersBAYHTR1405000 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 NoBAYHTR1405BRKB 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 YesBAYHTR1405PDC 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 NoBAYHTR1408000 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 NoBAYHTR1408BRKB 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 YesBAYHTR1408PDC 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 NoBAYHTR1410000 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 NoBAYHTR1410BRKB 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 YesBAYHTR1410PDC 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 NoBAYHTR1415BRKB 15.36 52,400 11.53 39,300 208/240/1/60 2 34.6/20.812 40/241 YesBAYHTR1419BRKB 19.20 65,500 14.42 44,200 208/240/1/60 2 27.8/41.612 32/481 YesBAYHTR1425BRKB 24.96 85,200 18.73 63,900 208/240/1/60 3 38.1/34.6/17.31 44/40/201 YesThree PhaseBAYHTR3410000 9.60 32,800 7.20 24,600 208/240/3/60 1 30 34.6 NoBAYHTR3415000 15.36 52,400 11.53 39,300 208/240/3/60 1 33 38.2 No(Example: L=Low, M=Medium, H=High Speed)PS = Minimum speed tap varies based on airh<strong>an</strong>dler installation position.AS = Heater application is affected based onwhether the outdoor unit is a heat pumpor cooling unit.000 = Pigtails, BRK = Contains circuitbreakers, PDC = Contains PullDisconnect* For heat pump applications, upflow positiononly minimum setting is 1200For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.MINIMUM HEATING AIRFLOW CFM COOLING/HEAT PUMP AIR FLOW - HEATER MATRIXAIRHANDLERMODELNUMBERNUMBER OFHEATER RACKSHEATER MODEL NUMBER BAYHTR—1405 000 1408 000 1410 000BRK BRK BRK 1415 BRK 3415 000 1419 BRK 1425 BRKPDC PDC PDC 15.36kW 15.36kW 19.20kW 24.96kW4.80kW 7.68kW 3410 0009.60kW1 2 2 2 2 4 5NUMBER OFCIRCUITS1 1 1 2 1 2 3TWE031E 700/1000 700/1000 700/1000 700/1125 700/1125 1000/1350 —TWE037E 600/700 600/900 600/900 1000/1300 1000/1300 1000/1350 —TWE040E 600/1100 600/1100 600/1100 1100/1400 1100/1400 1100/1400 1100/1400TWE049E 700/1400 700/1400 700/1400 1400/1600 1400/1600 1400/1600 1400/1600TWE062E 900/1500 900/1500 900/1500 1200/1800 1200/1800 1200/1800 1200/1800TWE065E 900/1500* 900/1500* 900/1500* 1200/1800 1200/1800 1200/1800 1200/18004TEE3F31A 700/1000 700/1000 700/1000 700/1125 700/1125 1000/1350 —4TEE3F37A 600/700 600/900 600/900 1000/1300 1000/1300 1000/1350 —4TEE3F40A 600/1100 600/1100 600/1100 1100/1400 1100/1400 1100/1400 1100/14004TEE3F49A 700/1400 700/1400 700/1400 1400/1600 1400/1600 1400/1600 1400/16004TEE3F65A 900/1500* 900/1500* 900/1500* 1200/1800 1200/1800 1200/1800 1200/18002/4TEC3F18A L/L L/M L/M — — — —2/4TEC3F24A L/L L/L L/L L/M L/M — —2/4TEC3F30A L/L L/L L/L L/M L/M — —2/4TEC3F36A L/L L/L L/L L/H L/H L/H —2/4TEC3F42A L/L L/L L/L L/PS L/PS L/H —2/4TEC3F48A L/L L/L L/L L/PS L/PS L/PS —2/4TEC3F60A L/L L/L L/L L/PS L/PS L/PS —2TGB3F18A L/L L/M L/H N/A N/A N/A —2TGB3F25A L/L L/M L/M L/H L/H N/A —2TGB3F30A L/L L/L L/L L/M L/M N/A —2TGB3F36A L/L L/L L/L L/M L/M N/A —2TGB3F42A L/L L/L L/L L/H L/H N/A2TGB3F48A L/L L/L L/L L/H L/H L/H —1 Circuit 1/Circuit 22 Heater c<strong>an</strong> be converted to single circuit power entry by using BAYSPEK140B. This kit allows a single power circuit to beused with electric heaters that contain two (2) circuit breakers.BAYSPEK140B to be used with BAYHTR1415BRKB/ BAYHTR1419BRKB only.CAUTION:Any power supply <strong>an</strong>d/or combination power supply, circuit or circuits must be wired <strong>an</strong>d protected in accord<strong>an</strong>ce with localelectrical codes.AH-9 Effective 1/1/06


Heaters for Split System <strong>an</strong>dConvertible Air H<strong>an</strong>dlers(Example: L=Low, M=Medium, H=High Speed)PS = Minimum speed tap varies based on airh<strong>an</strong>dler installation position.AS = Heater application is affected based onwhether the outdoor unit is a heat pumpor cooling unit.000 = Pigtails, BRK = Contains circuitbreakers, PDC = Contains PullDisconnect* For heat pump applications, upflow positiononly minimum setting is 1200MINIMUM HEATING AIRFLOW CFM COOLING/HEAT PUMP AIR FLOW - HEATER MATRIXAIRHANDLERMODELNUMBERNUMBER OFHEATER RACKSNUMBER OFCIRCUITSHEATER MODEL NUMBER BAYHTR—1405 000 1408 000 1410 000BRK BRK BRK 1415 BRK 3415 000 1419 BRK 1425 BRKPDC PDC PDC 15.36kW 15.36kW 19.20kW 24.96kW4.80kW 7.68kW 3410 0009.60kW1 2 2 2 2 4 51 1 1 2 1 2 3TWE018P L/L L/M L/M — — — —TWE024P L/L L/L L/L L/M L/M — —TWE030P L/L L/L L/L L/M L/M — —TWE036P L/L L/H L/H L/H —TWE042P PS PS L/H —TWE048P L/LPHASED PSOUTPS L/H L/HTWE060P L/L L/L L/L PS PS L/H L/HTWE063P L/L L/L L/L PS PS L/H L/H2TEP3F48B — L/L L/L L/L L/L — —2TEP3F63B — L/L L/L PS PS — —4TEP3F18A L/L L/M L/M — — — —4TEP3F24A L/L L/L L/L L/M L/M — —4TEP3F30A L/L L/L L/L L/M L/M — —4TEP3F36A L/L L/L L/L L/H L/H L/H —4TEP3F42A L/L L/L L/L PS PS L/H —PHASED OUT4TEP3F48A L/L L/L L/L PS PS L/H L/H4TEP3F63A L/L L/L L/L PS PS L/H L/H4TEP3F48B — L/L L/L L/L L/L — —4TEP3F63B — L/L L/L L/L L/L — —TWE018C L/L L/M L/M — — — —TWE024C L/L L/L L/L L/M L/M — —TWE030C L/L L/L L/L L/M L/M — —TWE036C L/L PS —TWE042C L/L AS —TWE048C L/LPHASED OUTL/L L/H L/HTWE060C/D AS L/L L/L L/L L/L L/H L/HTWG018A L/L L/M L/H — — — —TWG025A L/L L/M L/M L/H L/H — —TWG030A L/L L/L L/L L/M L/M — —TWG036/037A L/L L/L L/L L/M L/M — —TWG042A PHASED L/L L/L L/L L/H OUT L/H — —TWG048A L/L L/L L/L L/H L/H L/M —TWG060A L/L L/L L/L L/L L/L L/M L/HCAUTION: Any power supply <strong>an</strong>d/or combination power supply, circuit or circuits must be wired <strong>an</strong>d protected in accord<strong>an</strong>ce with localelectrical codes.Effective 1/1/06AH-10For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System Air H<strong>an</strong>dlersSingle Phase — 1½ through 5 Tons1 1 /2 through 5 TonsTWE-P (R-22) & 4TEP (R-410A)Convertible Air H<strong>an</strong>dlers• 12.0 SEER• Ships horizontal - converts to upflow byst<strong>an</strong>ding unit on end• Six-way convertibility-horizontal (left &right);front & rear access; upflow, downflow• "1- m<strong>an</strong>" installation opportunity• Electrical, refriger<strong>an</strong>t, condensate & bloweraccess convertible to either side• Compact 21" depth for easy installation• Multi-speed blower• Filter p<strong>an</strong>el stamped with word "filter"• 200/230 volt primary & 24 volt secondarytr<strong>an</strong>sformer• Low voltage wire nut connections• R 4.2-1" foil face insulated cabinet• Corrosion resist<strong>an</strong>t galv<strong>an</strong>ized metal withattractive finish• Superior condensate perform<strong>an</strong>ce• Enh<strong>an</strong>ced internally finned coil tubes• Direct drive motor• IAQ (Indoor Air Quality) sloped/free drainingp<strong>an</strong>, no st<strong>an</strong>ding water• Versatile duct fl<strong>an</strong>ge - allows flush fit 3/4", 1",1.5" duct insulation• Exclusive duct fl<strong>an</strong>ge thermal break/seal• External access to heater circuit breakers pull/disconnects• Polarized plugs for making electricalconnections from air h<strong>an</strong>dler control box toheaters• Non-bleed exp<strong>an</strong>sion valve refriger<strong>an</strong>t control• Approved for modular or m<strong>an</strong>ufactured homes• 1-year limited parts warr<strong>an</strong>ty• 5 year limited parts residential warr<strong>an</strong>ty• 1 year limited parts commercial warr<strong>an</strong>ty• Optional extended warr<strong>an</strong>tiesTable AH-11-A — R-22 Convertible (200/230/1/60)CoolingUnit Capacity F<strong>an</strong> Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) FCCV Speed H x W x D Weight (Ibs.) Opening12Opening1 Sizes Gas LiquidTWE018P130B 18,000 TXV-NB 3 43x21.5x21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 5/8 1/4TWE018P13FB (Air Tite TM ) 18,000 TXV-NB 3 43x21.5x21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 5/8 1/4TWE024P130B 24,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5/16TWE024P13FB(Air Tite TM ) 24,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5/16TWE030P130B 30,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5/16TWE030P13FB(Air Tite TM ) 30,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1PHASED OUT3/4TWE036P130B 36,000 TXV-NB 3 45x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 7/8TWE036P13FB(Air Tite TM ) 36,000 TXV-NB 3 45x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 7/8TWE042P130B 42,000 TXV-NB 3 51.75x23.5x 21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7/8TWE042P13FB(Air Tite TM ) 42,000 TXV-NB 3 51.75x23.5x 21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7/8TWE048P130B 48,000 TXV-NB 3 57.90x26x21 188 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 1 1 /8TWE048P13FB(Air Tite TM ) 48,000 TXV-NB 3 57.90x26x21 188 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 1 1 /8TWE060P130B 58,000 TXV-NB 3 57.90x26x21 193 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 1 1 /8TWE060P13FB(Air Tite TM ) 58,000 TXV-NB 3 57.90x26x21 193 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 1 1 /8TWE063P130B3 60,000 TXV-NB 3 62.75x26x21 211 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 1 1 /8TWE063P13FB3(Air Tite TM ) 60,000 TXV-NB 3 62.75x26x21 211 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 1 1 /82TEP3F48B1000B3(Air Tite TM ) 48,000 TXV-NB 3 57.90x23.5x21 166 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 1 1 /82TEP3F63B1000B3(Air Tite TM ) 60,000 TXV-NB 3 57.90x23.5x21 170 21.22x12.02 or 20.22x11.02 21.5x18.07 22x20x1 1 1 /85/163/83/83/83/83/83/83/83/83/83/83/83/8Table AH-11-B —R-410A Air-Tite (200/230/1/60)4TEP3F18A1000A 18,000 TXV-NB 3 43x21.5x21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 1 /2PHASED OUT4TEP3F24A1000A 24,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 5 /84TEP3F30A1000A 30,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3 /44TEP3F36A1000A 36,000 TXV-NB 3 45 x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3 /44TEP3F42A1000A 42,000 TXV-NB 3 51.75x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 3 /44TEP3F48A1000A 48,000 TXV-NB 3 57.90x26x21 188 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 7 /84TEP3F63A1000A3 60,000 TXV-NB 3 62.75x26x21 211 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 7 /84TEP3F48B1000B3 48,000 TXV-NB 3 57.90x23.5x21 166 21.22x12.02 or 20.22x11.02 21.5x18.07 20x25x1 7/84TEP3F63B1000B3 60,000 TXV-NB 3 57.90x23.5x21 170 21.22x12.02 or 20.22x11.02 21.5x18.07 20x25x1 7/81/45/165/163/83/83/83/83/83/8Table AH-11-C – AccessoriesModel Number Description Used WithBAY24X038 .................................. Plug-In Speed Ch<strong>an</strong>ge Relay Kit ................... TWE018-063P/2, 4TEP3F18-063PBAY99X1234 ............................... Knockout Cover Plate** ................................. TWE018-063P/2, 4TEP3F18-063PBAYSPEK140A ............................PHASEDSingle Power Entry Kit ................................... BAYHTR1415BRKAB,OUT1419BRKABTAYBASE100 ............................... Downflow Subbase ........................................ TWE042P/4TEP3F42PTAYBASE101 ............................... Downflow Subbase ........................................ TWE018-36P/4TEP3F18-36PTAYBASE102 ............................... Downflow Subbase ........................................ TWE048P-063P/2, 4TEP3F48-F63PTAYPLNM1005 ............................ Pedestal Plenum Upflow ................................ TWE018-042P/2, 4TEP3F48-F42PTAYPLNM101 ............................... Pedestal Plenum Upflow ................................ TWE048-063P/2, 4TEP3F48-F63P1 Actual opening does not include fl<strong>an</strong>ge.2 Adjustable duct fl<strong>an</strong>ge allows for a flush fit with 1 1 /2 inch insulation or 3 /4 inch or 1 inch insulation.3 Two piece cabinet.See Heater Tables on Pages AH-9For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.4 Minimum Order 1 unit (1 unit = 50 pcs.)5 For TWE018P-36P, 4TEP3F18A-36A, center on plenum for 2" difference in width.** Required if no electric heat is used.AH-11 Effective 1/1/06


Split System Air H<strong>an</strong>dlersSingle Phase — 1½ through 5 Tons1½ through 5 TonsTWE-C/DConvertible Air H<strong>an</strong>dlers• Ships horizontal - converts to upflow byst<strong>an</strong>ding unit on end.• Six-way convertibility-horizontal (left &right); front & rear access; upflow, downflow• "1-m<strong>an</strong>" installation opportunity• Electrical, refriger<strong>an</strong>t, condensate & bloweraccess convertible to either side• Versatile duct fl<strong>an</strong>ge - allows flush fit 3/4",1", or 1.5" duct insulation• Compact 21" depth for easy installation• Uses BAYHTR1400 series heaters• Corrosion resist<strong>an</strong>t galv<strong>an</strong>ized metal withattractive finish• IAQ (Indoor Air Quality) sloped/free drainingp<strong>an</strong>, no st<strong>an</strong>ding water• Approved for modular or m<strong>an</strong>ufacturedhomes• Superior condensate perform<strong>an</strong>ce• Enh<strong>an</strong>ced internally finned coil tubes• Direct drive motor• St<strong>an</strong>dard size filters• Multi-speed blower• 200/230 volt primary & 24 volt secondarytr<strong>an</strong>sformer• Low voltage wire nut connections• R 4.2-1" foil face insulated cabinet• External access to heater circuit breakers• Polarized plugs for making electricalconnections from air h<strong>an</strong>dler control box toheaters• Built-in indoor f<strong>an</strong> delay function forincreased efficiency. No kit required.• Motors internally isolated• 5 year limited parts residential warr<strong>an</strong>ty• 1 year limited parts commercial warr<strong>an</strong>ty• Optional extended warr<strong>an</strong>tiesTable AH-12-A — Convertible (200/230/1/60)CoolingUnit Capacity F<strong>an</strong> Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) FCCV Speed H x W x D Weight (Ibs.) Opening12Opening1 Sizes Gas LiquidTWE018C140B 18,000 .049 3 43x21.5x21 113 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 5/8TWE018C14FB (Air Tite TM ) 18,000 .049 3 43x21.5x21 113 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 5/8TWE024C140B 24,000 .057 3 43x21.5x21 115 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4TWE024C14FB (Air Tite TM ) 24,000 .057 3 43x21.5x21 115 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4TWE030C140B 30,000 .069 3 43x21.5x21 120 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1PHASED OUT3/4TWE030C14FB(Air Tite TM ) 30,000 .069 3 43x21.5x21 120 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4TWE036C140B 36,000 .069 3 43x21.5x21 125 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 7/8TWE036C14FB(Air Tite TM ) 36,000 .069 3 43x21.5x21 125 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 7/8TWE042C140C 42,000 .077 3 45x23.5x21 145 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7/8TWE042C14FC(Air Tite TM ) 42,000 .077 3 45x23.5x21 145 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7/8TWE048C140C 48,000 .083 3 51.75x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 1 1 /8TWE048C14FC(Air Tite TM ) 48,000 .083 3 51.75x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 1 1 /8TWE060D150B 60,000 TXV-B 3 57.90x23.5 x21 185 21.22x12.02 or 20.22x11.02 21.5x18.07 22x20x1 1 1 /8TWE060C15FD3(Air Tite TM ) 60,000 TXV-B 3 57.90x23.5 x21 185 21.22x12.02 or 20.22x11.02 21.5x18.07 22x20x1 1 1 /81/41/45/165/165/165/163/83/83/83/83/83/83/83/8Table AH-12-B – AccessoriesModel Number Description Used WithAY28X079 ...................................... Evap. Defrost Control Kit ................................. (All Cooling Models)AY28X084 ...................................... Evap. Defrost Control Kit ................................. (All Heat Pump Models)BAY24X038 .................................... Plug-in Speed Ch<strong>an</strong>ge Relay Kit ..................... TWE018-060C/DPHASED OUTBAY99X1235 ................................. Knockout Cover Plate* .................................... TWE018-060C/DBAYSPEK140A .............................. Single Power Entry Kit .................................... BAYHTR1415BRKAB, 1419BRKABTAYBASE100 ................................. Downflow Subbase ......................................... TWE042-060C/DTAYBASE101 ................................. Downflow Subbase ......................................... TWE018-036CTAYPLNM1004 ............................. Pedestal Plenum Upflow ................................. TWE018-060C/D1 Actual opening does not include fl<strong>an</strong>ge.2 Adjustable duct fl<strong>an</strong>ge allows for a flush fit with 1 1 / 2 inch insulation or 3 /4 inch or 1 inch insulation.3 Two piece cabinet.4 For TWE018-036 center on plenum for 2" difference in width.5 Minimum order 1 unit (1 unit = 50 pcs.).* Required if no electric heat is used.See Heater Tables on Pages AH-9Effective 1/1/06AH-12For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System Air H<strong>an</strong>dlersSingle Phase — 1½ through 5 Tons1 1 /2 through 5 TonsTWGConvertible Air H<strong>an</strong>dlers• Easy to cle<strong>an</strong> coil <strong>an</strong>d drain p<strong>an</strong>• Convertible upflow to horizontal left, (notools required) (matches installed units)• Designed to use “off the shelf” st<strong>an</strong>dardsize replaceable fiberglass filters –Industry Exclusive• Easy to remove filters <strong>an</strong>d blowers for easycle<strong>an</strong>ing <strong>an</strong>d replacement• Exp<strong>an</strong>ded application fit with narrowcabinet profile• Easy access electrical controls <strong>an</strong>dhook-up• Attractive enamel finish• R 4.2-1" foil face insulated cabinet• Versatile duct fl<strong>an</strong>ge – allows flush fit 3 /4, 1or 1 1 /2 inch duct insulation• Tight cabinet - low leak by design• IAQ (Indoor Air Quality) sloped/free drainingp<strong>an</strong>, no st<strong>an</strong>ding water• Durable, glass-filled Lex<strong>an</strong> – Never rust, noleak drain p<strong>an</strong>• Maximum depth 21 inches – fits pull-downstaircase• Exclusive maximum width 23 1 /2 inches – fits2 foot wide door• Built-in time delay• Full line 1 1 /2 – 5 tons• Direct drive motor• Filter p<strong>an</strong>el stamped with word “filter”• AccuTron TM refriger<strong>an</strong>t control• Exp<strong>an</strong>sion valve (Bleed TXV) st<strong>an</strong>dard on5-ton models• Polarized plugs for easy hook-up to electricheaters• 200/230 volt primary <strong>an</strong>d 24 volt secondarytr<strong>an</strong>sformer• Electric heaters with breaker option on allsizes• Approved for modular or m<strong>an</strong>ufacturedhomes• 5 year limited parts residential warr<strong>an</strong>ty• 1 year limited parts commercial warr<strong>an</strong>ty• Optional extended warr<strong>an</strong>tiesTable AH-13-A — Convertible (208-230/1/60)CoolingUnit Capacity F<strong>an</strong> Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) FCCV Speed H x W x D Weight (Ibs.) Opening12Opening1 Sizes Gas LiquidTWG018A140B 18,000 .049 3 43x16x21 108 14x12.12 or 13x11.12 14x18.22 14x20x1 5 /8PHASED OUTTWG025A140B 24,000 .057 3 45.70x18x21 124 16x12.12 or 15 x11.12 16x18.22 16x20x1 3 /4TWG030A140B 30,000 .067 3 45.70x18x21 125 16x12.12 or 15 x11.12 16x18.22 16x20x1 3 /4TWG036A140B 36,000 .067 3 52x18x21 135 16x12.12 or 15 x11.12 16x18.22 16x20x1 7 /8TWG037A140B 37,000 .067 3 43x21.5x21 145 19.5x12.12 or 18.5 x11.12 19.5x18.22 20x20x1 7 /8TWG042A140B 42,000 .075 3 43x23.5x21 160 21.5x12.12 or 20.5x11.12 21.5x18.22 20x20x1 7 /8TWG048A140B 48,000 .083 3 48.25x23.5x21 185 21.5x12.12 or 20.5x11.12 21.5x18.22 20x20x1 7 /8TWG060A150B 58,000 TXV-B 3 57.25x23.5x21 205 21.5x12.12 or 20.5x11.12 21.5x18.22 22x20x1 7 /81 Actual opening does not include fl<strong>an</strong>ge.2 Adjustable duct fl<strong>an</strong>ge allows for a flush fit with 3 /4, 1 or 1 1 /2 inch insulation.1/45/165/163/83/83/83/83/8See Heater Tables on Pages AH-9For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.AH-13 Effective 1/1/06


Split System Air H<strong>an</strong>dlersSingle Phase — 1½ through 3 Tons1 1 /2 through 3 Tons• Shipped in vertical upflow front return withfront access & convertible to vertical upflowbottom return• Tight cabinet - low leakage by design• Attractive enamel finish• R 4.2 – 1” insulation• Exclusive easy cle<strong>an</strong> coil <strong>an</strong>d drain p<strong>an</strong>• Easy to remove filters <strong>an</strong>d blowers for easycle<strong>an</strong>ing <strong>an</strong>d replacement• Filter rack with throw away filter• Easy access electrical controls <strong>an</strong>d hook –up 200/230 volt primary <strong>an</strong>d 24 voltsecondary tr<strong>an</strong>sformer• Built-in indoor f<strong>an</strong> delay function forincreased efficiency. No kit required• Multi-speed blower (2TFB)• Direct drive motor (2TFB)• Factory installed electric heaters• AccuTron TM refriger<strong>an</strong>t control (2TFB)• St<strong>an</strong>dard exp<strong>an</strong>sion valve kits are internallymounted (2TFB)• Factory installed service disconnect• Internally enh<strong>an</strong>ced finned coil tubing• Primary <strong>an</strong>d secondary drain connections• Approved for modular or m<strong>an</strong>ufacturedhomes• Variable speed ECM motor (2TFE)• Enh<strong>an</strong>ced Comfort-R TM (2TFE)• Soft start – cycle-on speed is ramped upgradually to reduce sound (2TFE)• Low voltage terminal board (2TFE)• Exp<strong>an</strong>sion valve refriger<strong>an</strong>t control (2TFE)• 5 year limited parts residential warr<strong>an</strong>ty• 1 year limited parts commercial warr<strong>an</strong>ty• Optional extended warr<strong>an</strong>tiesTable AH-14-A — (200/230/1/60)CoolingBottomUnit Capacity F<strong>an</strong> Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) FCCV Speed H x W x D Weight (Ibs.) Opening12Opening1 Sizes Gas Liquid2TFB4018A1D05A 18,000 .049 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 5/82TFB4018A1D08A 18,000 .049 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 5/82TFB4018A1D10A 18,000 .049 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1PHASED OUT5/82TFB4024A1D05A 24,000 .057 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 3/42TFB4024A1D08A 24,000 .057 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 3/42TFB4024A1D10A 24,000 .057 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 3/42TFB4030A1D05A 30,000 .067 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 3/42TFB4030A1D08A 30,000 .067 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 3/42TFB4030A1D10A 30,000 .067 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 3/42TFB4036A1D05A 30,000 .067 2 39x22x19.4 120 14 x 10.12 17.22 x 20 18x20x1 7/82TFB4036A1D08A 30,000 .067 2 39x22x19.4 120 14 x 10.12 17.22 x 20 18x20x1 7/82TFB4036A1D10A 30,000 .067 2 39x22x19.4 120 14 x 10.12 17.22 x 20 18x20x1 7/81/41/41/45/165/165/165/165/165/163/83/83/8Table AH-14-B — (200/230/1/60)CoolingBottomUnit Capacity F<strong>an</strong> Dimensions (in.) Shipping Supply Return Filter Line Size12 Opening1 Sizes Gas Liquid2TFE3025A1D05A 25,000 TXV-NB Var. 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 3/4 5/162TFE3025A1D08A 25,000 TXV-NB Var. 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 3/4 5/162TFE3025A1D10A 25,000 TXV-NB Var. 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 3/4 5/16Model No. (Btuh) FCCV Speed H x W x D Weight (Ibs.) Opening12PHASED OUT1 Actual opening does not include fl<strong>an</strong>ge.2 Adjustable duct fl<strong>an</strong>ge allows for a flush fit with 1 1 /2 inch insulation or 3 /4 inch or 1 inch insulation.Effective 1/1/06AH-14For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System Air H<strong>an</strong>dlersSingle Phase – 5 through 10 TonsThree Phase – 5 through 20 Tons5, 7 1 /2, 10, 15, 20 Ton TWEConvertible Air H<strong>an</strong>dlers(Upflow or Horizontal Only)• New 11th Digit "E" model ReliaTel <strong>an</strong>delectromech<strong>an</strong>cial compatible.• Upflow convertible to horizontal 5• Exp<strong>an</strong>sion valve factory installed• Check valves for heat pump applications• Belt drive blower• Factory installed motor, belt, sheaves,contactor, low voltage terminal board• One inch filters on 5 to 10 ton units (rackconvertible for field supplied two inch)• Captive screws remain on the p<strong>an</strong>elsfor service ease• Low voltage terminal board• Drain P<strong>an</strong>• Factory Installed (EDC) Evaporator DefrostControl• IAQ (Indoor Air Quality) sloped/free drainingp<strong>an</strong>, no st<strong>an</strong>ding water• Two inch filters factory installed on 15, 20ton units• Supplemental heaters (electric, water,steam) fits directly on unit discharge for lowinstallation cost• Single point power entry for reducedelectrical power installation cost• Unit fully assembled to reduce fieldinstallation costs• Compact design with low service clear<strong>an</strong>ceto reduce building requirements• Brazed refriger<strong>an</strong>t piping connections• F<strong>an</strong> relay UL listed <strong>an</strong>d CSA Certified• Optional extended warr<strong>an</strong>tiesTable AH-15-A — Single Circuit CoilShippingMax Fuse SizeUnit Power Supply Capacity Drive Dimensions (in.)4 Weight or Max CircuitTons Model No. Volts/Phase/Hz (Btuh) FCCV Type H x W x D (Ibs.) MCA* Breaker3*Single Phase5 TWE060A100E 208-230/1/60 60,000 TXV Belt 48 x 39 x 23 298 7 157 1 /2 TWE090A100E1 208-230/1/60 90,000 TXV Belt 54 x48 x 26 388 8 1510 TWE120A100E1 208-230/1/60 120,000 TXV Belt 54 x 64 x 26 439 11 15Three Phase5 TWE060A300E 208-230/3/60 60,000 TXV Belt 48 x 39 x 23 298 4 155 TWE060A400E 460/3/60 60,000 TXV Belt 48 x 39 x 23 298 2 155 TWE060AW00E 575/3/60 60,000 TXV Belt 48 x 39 x 23 298 2 157 1 /2 TWE090A300E12 208-230/3/60 90,000 TXV Belt 54 x 48 x 26 388 7 157 1 /2 TWE090AW00E1 575/3/60 90,000 TXV Belt 54 x48 x 23 298 4 1510 TWE120A300E12 208-230/3/60 120,000 TXV Belt 54 x 64 x 26 439 8 1510 TWE120AW00E1 575/3/60 120,000 TXV Belt 54 x 64 x 26 439 4 15Table AH-15-B— Dual Circuit CoilShippingMax Fuse SizeUnit Power Supply Capacity Drive Dimensions (in.)4 Weight or Max CircuitTons Model No. Volts/Phase/Hz (Btuh) FCCV Type H x W x D (Ibs.) MCA* Breaker3*Single Phase5 TWE060B100E 208-230/1/60 60,000 TXV Belt 48 x 39 x 23 298 7 157 1 /2 TWE090B100E 208-230/1/60 90,000 TXV Belt 54 x 48 x 26 388 8 1510 TWE120B100E 208-230/1/60 120,000 TXV Belt 54 x 64 x 26 439 11 15Three Phase5 TWE060B300E 208-230/3/60 60,000 TXV Belt 48 x 39 x 23 298 4 155 TWE060B400E 460/3/60 60,000 TXV Belt 48 x 39 x 23 298 2 157 1 /2 TWE090B300E12 208-230/3/60 90,000 TXV Belt 54 x 48 x 26 388 7 1510 TWE120B300E12 208-230/3/60 120,000 TXV Belt 54 x 64 x 26 439 8 1510 TWE120BW00E1 575/3/60 120,000 TXV Belt 54 x 64 x 26 439 4 1515 TWE180B300E 208-230/3/60 180,000 TXV Belt 69 x 80 x 28 754 12 2015 TWE180B400E 460/3/60 180,000 TXV Belt 69 x 80 x 28 754 6 1515 TWE180BW00E 575/3/60 180,000 TXV Belt 69 x 80 x 28 754 5 1520 TWE240B300E 208-230/3/60 240,000 TXV Belt 72 x 93 x 30 886 19 3020 TWE240B400E 460/3/60 240,000 TXV Belt 72 x 93 x 30 886 9 1520 TWE240BW00E 575/3/60 240,000 TXV Belt 72 x 93 x 30 886 7 151 Control tr<strong>an</strong>sformer not included. Order control tr<strong>an</strong>sformer accessory when matching these air h<strong>an</strong>dlers with 4-6 ton condensing units.2 Ships wired for 208-230/3/60. Field convertible to 460/3/60.3 HACR type circuit breaker per NEC.4 Dimensions based on Upflow position.5 All air h<strong>an</strong>dlers are shipped with the drain p<strong>an</strong> installed in the horizontal position. If <strong>an</strong> alternate position is required, the drain p<strong>an</strong> should be repositioned beforesetting the air h<strong>an</strong>dler.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.AH-15 Effective 1/1/06


Split System Air H<strong>an</strong>dlersSingle Phase – 5 through 10 TonsThree Phase – 5 through 20 TonsTable AH-16-A — Supplementary Heaters1Model No. Power Supply kW Rating Used WithBAYHTRL106A 208/240/1/60 4.33/5.76 TWE060-120A1, TWE060-120B1BAYHTRL112A 208/240/1/60 8.65/11.52 TWE060-120A1, TWE060-120B1BAYHTRL117A 208/240/1/60 12.98/17.28 TWE060-120A1, TWE060-120B1BAYHTRL123A 208/240/1/60 17.30/23.04 TWE060-120A1, TWE060-120B1BAYHTRL129A 208/240/1/60 21.65/28.80 TWE090-120A1, TWE090-120B1BAYHTRL305A 208/240/3/60 3.75/5.00 TWE060-120A3, TWE060-120B3BAYHTRL310A 208/240/3/60 7.45/9.96 TWE060-120A3, TWE060-120B3BAYHTRL315A 208/240/3/60 11.25/14.96 TWE060-120A3, TWE060-120B3BAYHTRL325A 208/240/3/60 18.71/24.92 TWE060-120A3, TWE060-120B3BAYHTRL335A 208/240/3/60 26.20/34.88 TWE090-120A3, TWE090-120B3BAYHTRL405A 460/3/60 5.00 TWE060A4,B4, TWE090-120A32, TWE090-120B32BAYHTRL410A 460/3/60 9.96 TWE060A4,B4, TWE090-120A32, TWE090-120B32BAYHTRL415A 460/3/60 14.96 TWE060A4,B4, TWE090-120A32, TWE090-120B32BAYHTRL425A 460/3/60 24.92 TWE060A4,B4, TWE090-120A32, TWE090-120B32BAYHTRL435A 460/3/60 34.88 TWE090,120A32, TWE090-120B32BAYHTRLW05A 575/3/60 5.00 TWE060AW, TWE090-120AW, TWE090-120BWBAYHTRLW10A 575/3/60 9.96 TWE060AW, TWE090-120AW, TWE090-120BWBAYHTRLW15A 575/3/60 14.96 TWE060AW, TWE090-120AW, TWE090-120BWBAYHTRLW25A 575/3/60 24.92 TWE060-120AWBAYHTRLW35A 575/3/60 34.88 TWE090,120AWBAYHTRM310A 208/230/3/60 7.50/10.00 TWE180-240B3BAYHTRM320A 208/230/3/60 14.96/19.92 TWE180-240B3BAYHTRM330A 208/230/3/60 22.50/29.92 TWE180-240B3BAYHTRM350A 208/230/3/60 37.42/49.84 TWE180-240B3BAYHTRM410A 460/3/60 10.00 TWE180-240B4BAYHTRM420A 460/3/60 19.92 TWE180-240B4BAYHTRM430A 460/3/60 29.92 TWE180-240B4BAYHTRM450A 460/3/60 49.84 TWE180-240B4BAYHTRMW10A 575/3/60 10.00 TWE180-240BWBAYHTRMW20A 575/3/60 19.92 TWE180-240BWBAYHTRMW30A 575/3/60 29.92 TWE180-240BWBAYHTRMW50A 575/3/60 49.84 TWE180-240BW1 Air H<strong>an</strong>dler with heater of same voltage is single circuit single point.2 Field converted to 460/3/60.Effective 1/1/06AH-16For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System Air H<strong>an</strong>dlersAccessories – 5 through 20 TonsTable AH-17-A – AccessoriesModel Number Description Used WithBAYBASE001A1 ............. Subbase (38 W x 22 L) .............................................................................................. TWE060A, TWE060BBAYBASE002A1 ............. Subbase (47 1 /2 W x 25 L) .......................................................................................... TWE090A, TWE090BBAYBASE003A1 ............. Subbase (63 1 /2 W x 25 L) .......................................................................................... TWE120A, TWE120BBAYBASE004A1 ............. Subbase (79 1 /2 W x 27 5 /8 L) ...................................................................................... TWE180BBAYBASE005A1 ............. Subbase (92 1 /2 W x 30 7 /16 L) ..................................................................................... TWE240BBAYDRKT001A ................. Condensate Drain Kit ................................................................................................ TWE060BAYDRKT002A ................. Condensate Drain Kit ................................................................................................ TWE090BAYDRKT003A ................. Condensate Drain Kit ................................................................................................ TWE120BAYDRKT004A ................. Condensate Drain Kit ................................................................................................ TWE180BAYDRKT005A ................. Condensate Drain Kit ................................................................................................ TWE240BAYGRLE001A ................. Return Air Grille ......................................................................................................... TWE060A, TWE060BBAYGRLE002A ................. Return Air Grille ......................................................................................................... TWE090A, TWE090BBAYGRLE003A ................. Return Air Grille ......................................................................................................... TWE120A, TWE120BBAYGRLE004A ................. Return Air Grille ......................................................................................................... TWE180BBAYGRLE005A ................. Return Air Grille ......................................................................................................... TWE240BBAYHSMT022B ................. Oversized Motor 230/1/60 – 1 HP ............................................................................. TWE060A, TWE060BBAYHSMT023B ................. Oversized Motor 230/1/60 – 2 HP ............................................................................. TWE090A, TWE090BBAYHSMT025B ................. Oversized Motor 230-460/3/60 – 1 HP ...................................................................... TWE060A3, A4, B3, B4BAYHSMT026A ................. Oversized Motor 230-460/3/60 – 2 HP ...................................................................... TWE090A3, TWE090B3BAYHSMT027B ................. Oversized Motor 230-460/3/60 – 3 HP ...................................................................... TWE120A3BAYHSMT028A ................. Oversized Motor 230/3/60 – 5 HP ............................................................................. TWE180B3BAYHSMT029A ................. Oversized Motor 230-460/3/60 – 7.5 HP ................................................................... TWE240B3,B4BAYHSMT030A ................. Oversized Motor 460/3/60 – 5 HP ............................................................................. TWE180B4BAYHSMT035AA ............... Oversized Motor 575/3/60 – 5 HP ............................................................................. TWE180BWBAYHSMT036AA ............... Oversized Motor 575/3/60 – 7.5 HP .......................................................................... TWE240BWBAYISLT003A234 ........ Rubber-In-Shear Isolator - Floor ................................................................................ TWE060-090A, TWE060-090BBAYISLT004A234 ........ Rubber-In-Shear Isolator - Floor ................................................................................ TWE120A, TWE120BBAYISLT009A13 ............ Rubber-In-Shear Isolator - Floor ................................................................................ TWE180BBAYISLT012B1 ............... Rubber-In-Shear Isolator - Suspended ...................................................................... TWE180BBAYISLT013B34 ............ Rubber-In-Shear Isolator - Suspended ...................................................................... TWE060A, TWE060BBAYISLT014A34 ............ Rubber-In-Shear Isolator - Suspended ...................................................................... TWE090A, TWE090BBAYISLT015B34 ............ Rubber-In-Shear Isolator - Suspended ...................................................................... TWE120A, TWE120BBAYISLT016B1 ............... Rubber-In-Shear Isolator - Suspended ...................................................................... TWE240BBAYISLT018A23 ............ Spring Isolater - Floor ................................................................................................ TWE060A, TWE060BBAYISLT019A23 ............ Steel Spring Isolater - Floor ....................................................................................... TWE090-120A, TWE090-120BBAYISLT021A12 ............ Rubber-In-Shear Isolator - Floor ................................................................................ TWE180-240BBAYISLT028A3 ............... Steel Spring Isolater - Suspended ............................................................................. TWE060A, TWE060BBAYISLT029A3 ............... Spring Isolater - Suspended ...................................................................................... TWE090-120A, TWE090-120BBAYISLT030A1 ................ Rubber-In-Shear Isolator - Suspended ...................................................................... TWE180BBAYISLT031B1 ................ Rubber-In-Shear Isolator - Suspended ...................................................................... TWE240BBAYLSDR001A .................. Low Static Drive Kit ................................................................................................... TWE240BBAYLSDR003A .................. Low Static Drive Kit ................................................................................................... TWE090A, TWE090BBAYPLNM015A56 ......... Discharge Plenum <strong>an</strong>d Grille ..................................................................................... TWE060A, TWE060BBAYPLNM016A56 ......... Discharge Plenum <strong>an</strong>d Grille ..................................................................................... TWE090A, TWE090BBAYPLNM017A56 ......... Discharge Plenum <strong>an</strong>d Grille ..................................................................................... TWE120A, TWE120BBAYPLNM018A56 ......... Hydronic Coil Discharge Plenum <strong>an</strong>d Grille .............................................................. BAYWATR015A, 020BBAYPLNM019A56 ......... Hydronic Coil Discharge Plenum <strong>an</strong>d Grille .............................................................. BAYWATR016A, 021BBAYPLNM020A5 ............. Hydronic Coil Discharge Plenum <strong>an</strong>d Grille .............................................................. BAYWATR012A, 017BBAYPLNM021A5 ............. Hydronic Coil Discharge Plenum <strong>an</strong>d Grille .............................................................. BAYWATR013A, 018BBAYPLNM022A5 ............. Hydronic Coil Discharge Plenum <strong>an</strong>d Grille .............................................................. BAYWATR014A, 019BBAYPLNM025A7 ............. Electric Heat Discharge Plenum <strong>an</strong>d Grille For use with TWE060A, TWE060B ....... BAYHTRL117A, 315A, 415ABAYPLNM026A7 ............. Electric Heat Discharge Plenum <strong>an</strong>d Grille ............................................................... BAYHTRL117A, 123A, BAYHTRL315A, 325A,For use with TWE090A, TWE090B ............................................................................ BAYHTRL415A, 425ABAYPLNM027A7 ............. Electric Heat Discharge Plenum <strong>an</strong>d Grille ............................................................... BAYHTRL117A, 123A, BAYHTRL315A, 325A,For use with TWE120A, TWE120B ............................................................................ BAYHTRL415A, 425ABAYPLNM028A7 ............. Electric Heat Discharge Plenum <strong>an</strong>d Grille - 15 Ton ................................................. BAYHTRM330A,430A,W30ABAYPLNM029A7 ............. Electric Heat Discharge Plenum <strong>an</strong>d Grille - 20 Ton ................................................. BAYHTRM330A,430A,W30ABAYTFMR003A89 ......... 77va Tr<strong>an</strong>sformer 230v/24v ....................................................................................... TWE090-120A3, TWE090-120B3BAYTFMR004A890 ...... 77va Tr<strong>an</strong>sformer 460v/24v ....................................................................................... TWE090-120A3, TWE090-120B3BAYTFMR005A89 ......... 77va Tr<strong>an</strong>sformer 575v/24v ....................................................................................... TWE090AW,TWE120AW,BWBAYTFMR007A89q ...... 75va Tr<strong>an</strong>sformer Relay <strong>an</strong>d Terminal Connections 230v/24v .................................. TWE090B3-TWE120B3BAYTFMR008A80q ...... 87va Tr<strong>an</strong>sformer Relay <strong>an</strong>d Terminal Connections 460v/24v .................................. TWE090B3-TWE120B3BAYWATR012A ................. Steam Coil Encl. & Assm. (38 W x 22 1 /8 L x 14 H) ................................................... TWE60A, TWE060BBAYWATR013A ................. Steam Coil Encl. & Assm. (47 5 /8 W x 25 3 /16 L x 14 H) ............................................... TWE090A, TWE090BBAYWATR014A ................. Steam Coil Encl. & Assm. (63 5 /8 W x 25 3 /16 L x 16 H) ............................................... TWE120A, TWE120BBAYWATR015A ................. Steam Coil Encl. & Assm. (79 5 /8 W x 27 13 /16 L x 16 H) .............................................. TWE180BBAYWATR016A ................. Steam Coil Encl. & Assm. (92 5 /8 W x 30 5 /8 L x 18 H) ................................................ TWE240BBAYWATR017C ................. Hot Water Coil Encl. & Assm. (38 W x 22 1 /8 L x 14 H) .............................................. TWE060A, TWE060BBAYWATR018C ................. Hot Water Coil Encl. & Assm. (47 5 /8 W x 25 3 /16 L x 14 H) ......................................... TWE090A, TWE090BBAYWATR019C ................. Hot Water Coil Encl. & Assm. (63 5 /8 W x 25 3 /16 L x 16 H) ......................................... TWE120A, TWE120BBAYWATR020C ................. Hot Water Coil Encl. & Assm. (79 5 /8 W x 27 13 /16 L x 16 H) ........................................ TWE180BBAYWATR021C ................. Hot Water Coil Encl. & Assm. (92 5 /8 W x 30 5 /8 L x 18 H) .......................................... TWE240BBAYWRKT001A ............... Wire Kit to Achieve 180° Reversible Discharge ......................................................... TWE060-090-120A, TWE060-090-120B1 When Air H<strong>an</strong>dler is in vertical position <strong>an</strong>d close proximity trapping of condensate is required,use of subbase is recommended.2 Requires use of subbase accessory.3 Do not use with units having steam or hot water coil.4 Do not use if blower will operate less th<strong>an</strong> 600 rpm.5 For vertical use only.6 Discharge Plenum <strong>an</strong>d Grille c<strong>an</strong>not be used with Electric or Hydronic Heat options.7 See data catalog for minimum <strong>an</strong>d maximum airflow requirements.8 Required when 7 1 /2 – 10 ton Air H<strong>an</strong>dlers are matched with 4 – 6 ton outdoor units.9 Required when used with Qty 2 Split System condensing units.0 When field connected for 460V.q Required when used with Qty 2 Split System Heat Pump.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.AH-17 Effective 1/1/06


Split System Air H<strong>an</strong>dlers5 through 20 TonsEHPABPEHSBIRGCGLAFactory SuppliedAccessoriesAir H<strong>an</strong>dler (TWE 5 – 20 Tons)Outdoor Condensing Unit(TTA - Cooling 7 1/2 – 20 Tons)(TWA - Heat Pump 7 1/2 – 20 Tons)Discharge Plenum <strong>an</strong>d Grille(BAYPLNM)Electric Heater <strong>an</strong>d Casing (BAYHTRL)Fits on Top of Unit (13 H x 30 W x 17 D)Subbase (BAYBASE)Isolators (BAYISLT)Return Grille (BAYGRLE)Coil Guards (BAYGARD)Low Ambient Control (BAYLOAM)WCWCSteam/Hot Water Coil (BAYWATR)ATo Convert from Vertical toHorizontal Simply Lay DownDrain Connections at Top<strong>an</strong>d Bottom of CoilSBIIRGCGDrain Connections at Top<strong>an</strong>d Bottom of CoilBLAEffective 1/1/06AH-18For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


<strong>Tr<strong>an</strong>e</strong> Profit-abilitySell-abilityIndustry leader <strong>an</strong>d br<strong>an</strong>d reputationHigher efficiency single-stage furnaceGreater reliabilityQuieter operationInstall-abilityAir cle<strong>an</strong>er <strong>an</strong>d humidifier leadsUpflow/horizontal leftDownflow/horizontal rightLeft/right gas <strong>an</strong>d electrical hookupsDirect-vent optionService-abilityQuarter-turn blower door latcheson upflow modelsSelf-diagnostic controlsCommon parts across familyCompatible with higher SEERoutdoor unitsPerform<strong>an</strong>ce-ability4-speed, high efficiency motor90% efficiency on gasInsulated blower door <strong>an</strong>d cabinetsave energy <strong>an</strong>d reduce soundAutomotive-grade gaskets reduceair sound <strong>an</strong>d infiltrationRely-abilityEach is factory tested before shippingSilicon nitride igniter100% fresh air optionIntegrated furnace controlAluminized heat exch<strong>an</strong>gerMulti-port in-shot burnersTRANE XT90 HIGH EFFICIENCY FURNACEMORE ENHANCED COMFORT, EXTRA-EFFICIENT PROFITS.The TRANE XT90 furnace provides a higher efficiency,single-stage furnace option with a bonus of addedreliability. Because it uses less electricity in bothits heating <strong>an</strong>d cooling operations, it will appeal toefficiency-minded customers for residential newTRANE LIMITED WARRANTYLifetime heat exch<strong>an</strong>ger5-year functional partsconstruction <strong>an</strong>d replacement. It’s easy to install<strong>an</strong>d service. And c<strong>an</strong> accommodate upgrades to higherSEER outdoor units. Install it <strong>an</strong>d provide <strong>an</strong> enh<strong>an</strong>cedcomfort experience that will make you <strong>an</strong>d yourcustomers more comfortable, too.TRANEXT90FURNACEReliable perform<strong>an</strong>cePrecision engineering, designinnovation <strong>an</strong>d rigorous testingfor reliable, long-lastingperform<strong>an</strong>ce <strong>an</strong>d durability.Better indoor airAdd a TRANE Cle<strong>an</strong>Effects TMair filtration system to remove up to99.98% of airborne allergens fromthe filtered air for a cle<strong>an</strong>er, morecomfortable home.Comfort controlGive your customers bettercomfort control with a <strong>Tr<strong>an</strong>e</strong>digital or programmablethermostat.Enh<strong>an</strong>ced comfortIntelligently designed todeliver maximum comfort withfuel efficiency.Efficient operationDesigned with innovativetechnological touches throughoutto provide the ultimate in energyefficient operation that lowerscustomers’ heating costs.


TRANE XT90 HIGH EFFICIENCY FURNACETRANEXT90FURNACEFeatures <strong>an</strong>d components may vary by model<strong>an</strong>d are shown for illustration purposes only.92 8651471031 62345High efficiency blower motorControlled by a built-in microcomputer <strong>an</strong>d on-boardrelays. Fixed 45-second time delay controls the indoorblower in heating cycles. Blower off timing is adjustableby presets, allowing you to customize comfort in the home.Adaptive silicon nitride hot surface igniterPrevents overheating, which results in a highly reliable ignitionsystem <strong>an</strong>d longer service life.Heavy steel insulated cabinetEasy-to-install sizes in four industry-st<strong>an</strong>dard widths; 40"tall. Holds more heat in the furnace <strong>an</strong>d ensures greaterdurability <strong>an</strong>d quieter operation.Self-diagnostic controlsComplete diagnostics for easy servicing. Also includes asystem fault <strong>an</strong>alysis for quick gas flow shutoff, coupled withautomatic ignition retry after sensing fault correction.Easy-access doorsQuarter-turn dual door latches provide quick <strong>an</strong>d easyaccess for servicing (upflow models only).78910Multi-port in-shot burnersPerfectly shape the flame cone for the maximum heat possiblewhile using less fuel. No service adjustment necessary.Automotive-grade gaskets <strong>an</strong>d insulatedblower compartmentHelp reduce operating sound <strong>an</strong>d air infiltration.Aluminized steel heat exch<strong>an</strong>gerCrimped, not welded, to prevent cracks from heat stress.Stamped serpentine ch<strong>an</strong>nel offers the greatest efficiencyin less space. Backed by our 20-year, non-prorated limitedwarr<strong>an</strong>ty.Direct vent100% fresh air option reduces heat exch<strong>an</strong>ger corrosion <strong>an</strong>dassures adequate combustion air.Secondary heat exch<strong>an</strong>gerThe secondary heat exch<strong>an</strong>ger is made of AL29-4C TM stainlesssteel to capture more of the heat your customers pay for.Backed by a lifetime limited warr<strong>an</strong>ty.XT90 High Efficiency, Upflow, Horizontal LeftCooling CFMModel Number AFUE Height (in.) Width (in.) Depth (in.) (Nom. tons)TUX1B040A9H21A 92.1 40.00 17.50 28.00 2.0TUX1B060A9H31A 92.1 40.00 17.50 28.00 3.0TUX1B080A9H31A 92.1 40.00 17.50 28.00 3.0TUX1C100A9H41A 92.1 40.00 21.00 28.00 4.0TUX1D120A9H51A 92.1 40.00 24.50 28.00 5.0XT90 High Efficiency, Downflow, Horizontal RightTDX1B040A9H31A 91.0 40.00 17.50 28.00 3.0TDX1B060A9H31A 91.0 40.00 17.50 28.00 3.0TDX1B080A9H31A 91.0 40.00 17.50 28.00 3.0TDX1C100A9H41A 91.0 40.00 21.00 28.00 4.0TDX1D120A9H51A 91.0 40.00 24.50 28.00 5.0As part of our continuous product improvement, <strong>Tr<strong>an</strong>e</strong> reserves the right to ch<strong>an</strong>ge specifications <strong>an</strong>d design without notice.Warr<strong>an</strong>ties generate additional income.<strong>Tr<strong>an</strong>e</strong> extended warr<strong>an</strong>ties create additional income. Selling extendedwarr<strong>an</strong>ties is <strong>an</strong>other way to protect your customers <strong>an</strong>d generatefuture business.It all adds up to a stellar reputation.We know that when you recommend our products to your loyal customers,you are placing your livelihood <strong>an</strong>d reputation in our h<strong>an</strong>ds. We saluteyour expertise in delivering <strong>Tr<strong>an</strong>e</strong> technology <strong>an</strong>d innovation to yourcustomers—making their homes better places for living. You are thereason we c<strong>an</strong> say, “expect more from <strong>Tr<strong>an</strong>e</strong>.”tr<strong>an</strong>e.com© 2005 TRANE ® a business of Americ<strong>an</strong> St<strong>an</strong>dard Comp<strong>an</strong>ies. All rights reserved. Pub. No. XT90FURN-01 09/05


<strong>Tr<strong>an</strong>e</strong> Profit-abilityTRANE XT80 HIGH EFFICIENCY FURNACETRANEXT80FURNACESell-abilityIndustry leader <strong>an</strong>d br<strong>an</strong>d reputationHigher efficiency single-stage furnaceGreater reliabilityQuieter operationInstall-abilityAir cle<strong>an</strong>er <strong>an</strong>d humidifier leadsUpflow/horizontal left or rightDownflow/horizontal left or rightLeft/right gas <strong>an</strong>d electrical hookupsService-abilityQuarter-turn blower door latcheson upflow modelsSelf-diagnostic controlsCommon parts across familyCompatible with higher SEERoutdoor unitsPerform<strong>an</strong>ce-ability4-speed high efficiency motor80% efficiency on gasInsulated blower door <strong>an</strong>d cabinetsave energy <strong>an</strong>d reduce soundAutomotive-grade gaskets reduceair sound <strong>an</strong>d infiltrationRely-abilityEach is factory tested before shippingSilicon nitride igniterIntegrated furnace controlAluminized heat exch<strong>an</strong>gerMulti-port in-shot burnersOUR NEW SINGLE-STAGE, HIGH EFFICIENCY XT80 FURNACE REALLY HEATS UP YOUR SALES.With a high efficiency motor, the TRANE XT80 furnacesets the stage for increased sales. It uses lesselectricity in both its heating <strong>an</strong>d cooling operations,so it’s very attractive for new residential construction<strong>an</strong>d replacement. And it’s easy for you to install <strong>an</strong>dTRANE LIMITED WARRANTY20-year heat exch<strong>an</strong>ger5-year functional partsservice. It also c<strong>an</strong> accommodate upgrades to higherSEER outdoor units. The XT80 furnace is a highefficiency product that both you <strong>an</strong>d your customersc<strong>an</strong> be comfortable with.Reliable perform<strong>an</strong>cePrecision engineering, designinnovation <strong>an</strong>d rigorous testingfor reliable, long-lastingperform<strong>an</strong>ce <strong>an</strong>d durability.Better indoor airAdd a TRANE Cle<strong>an</strong>Effects TMairfiltration system to remove up to99.98% of airborne allergens fromthe filtered air for a cle<strong>an</strong>er,more comfortable home.Comfort controlGive your customers better comfortcontrol with a <strong>Tr<strong>an</strong>e</strong> digital orprogrammable thermostat.Enh<strong>an</strong>ced comfortIntelligently designed todeliver maximum comfort withfuel efficiency.Efficient operationDesigned with innovativetechnological touches throughoutto provide the ultimate in energyefficient operation.


TRANE XT80 HIGH EFFICIENCY FURNACETRANEXT80FURNACEFeatures <strong>an</strong>d components may vary by model<strong>an</strong>d are shown for illustration purposes only.725641831 5234High efficiency blower motorControlled by a built-in microcomputer <strong>an</strong>d on-boardrelays. Fixed 45-second time delay controls the indoorblower in heating cycles. Blower off-timing is adjustable bypresets, allowing you to customize comfort in the home.Adaptive silicon nitride hot surface igniterPrevents overheating, which results in a highly reliableignition system <strong>an</strong>d longer service life.Heavy steel insulated cabinetComes in easy-to-install sizes in four industry st<strong>an</strong>dard widths;40" tall. Holds more heat in the furnace <strong>an</strong>d ensures greaterdurability <strong>an</strong>d quieter operation.Self-diagnostic controlsComplete diagnostics for easy servicing. Also includes a systemfault <strong>an</strong>alysis for quick gas flow shutoff, coupled withautomatic ignition retry after sensing fault correction.678Easy-access doorsQuarter-turn dual door latches provide quick <strong>an</strong>d easyaccess for servicing (upflow models only).Multi-port in-shot burnersPerfectly shape the flame cone for the maximum heatpossible while using less fuel. No service adjustmentnecessary.Automotive-grade gaskets <strong>an</strong>d insulatedblower compartmentHelp reduce operating sound <strong>an</strong>d air infiltration.Aluminized steel heat exch<strong>an</strong>gerCrimped, not welded, to prevent cracks from heat stress.Stamped serpentine ch<strong>an</strong>nel offers the greatest efficiencyin less space. Backed by our 20-year, non-prorated limitedwarr<strong>an</strong>ty.XT80 High Efficiency, Upflow HorizontalCooling CFMModel Number AFUE Height (in.) Width (in.) Depth (in.) (Nom. tons)TUD1A040A9H21A 80.0 40.00 14.50 28.00 2.0TUD1B060A9H31A 80.0 40.00 17.50 28.00 3.0TUD1B080A9H31A 80.0 40.00 17.50 28.00 3.0TUD1C080A9H41A 80.0 40.00 21.00 28.00 4.0TUD1B100A9H31A 80.0 40.00 17.50 28.00 3.0TUD1C100A9H51A 80.0 40.00 21.00 28.00 5.0TUD1D120A9H51A 80.0 40.00 24.50 28.00 5.0TUD1D140A9H51A 80.0 40.00 24.50 28.00 5.0XT80 High Efficiency, Downflow HorizontalTDD1B060A9H31A 80.0 40.00 17.50 28.00 3.0TDD1B080A9H31A 80.0 40.00 17.50 28.00 3.0TDD1C100A9H51A 80.0 40.00 21.00 28.00 5.0TDD1D120A9H51A 80.0 40.00 24.50 28.00 5.0As part of our continuous product improvement, <strong>Tr<strong>an</strong>e</strong> reserves the right to ch<strong>an</strong>ge specifications <strong>an</strong>d design without notice.Warr<strong>an</strong>ties generate additional income.<strong>Tr<strong>an</strong>e</strong> extended warr<strong>an</strong>ties create additional income. Selling extendedwarr<strong>an</strong>ties is <strong>an</strong>other way to protect your customers <strong>an</strong>d generatefuture business.It all adds up to a stellar reputation.We know that when you recommend our products to your loyal customers,you are placing your livelihood <strong>an</strong>d reputation in our h<strong>an</strong>ds. We saluteyour expertise in delivering <strong>Tr<strong>an</strong>e</strong> technology <strong>an</strong>d innovation to yourcustomers—making their homes better places for living. You are thereason we c<strong>an</strong> say “expect more from <strong>Tr<strong>an</strong>e</strong>.”tr<strong>an</strong>e.com© 2005 TRANE ® a business of Americ<strong>an</strong> St<strong>an</strong>dard Comp<strong>an</strong>ies. All rights reserved. Pub. No. XT80FURN-01 09/05


TRANE ALUMINUM HIGH EFFICIENCY COMFORT TM COILSTR ALCOILS<strong>Tr<strong>an</strong>e</strong> Profit-abilitySell-abilityIndustry leader with impeccablebr<strong>an</strong>d reputationPrecision engineeredInstall-abilityFlush fit, easy attachmentAvailable for different furnace widthsUpflow, downflow <strong>an</strong>d horizontalleft airflowTRANE LIMITED WARRANTY10-year functional partsService-abilityEasy-access cabinetSuction pressure service portRemovable inner <strong>an</strong>d outer p<strong>an</strong>elsTXV with mech<strong>an</strong>ical fittingsPerform<strong>an</strong>ce-abilityTwo-way, sloped drain p<strong>an</strong>Foil-insulated cabinetNon-bleed TXVRely-abilityNon-corrosive partsTXV protects from refriger<strong>an</strong>tfloodingINNOVATIVE TECHNOLOGY. INCREASED PROFIT MARGIN.Corrosion has been a long-st<strong>an</strong>ding problem affecting efficiency there is <strong>an</strong>d exceptional durability whenevery major <strong>HVAC</strong> m<strong>an</strong>ufacturer. <strong>Tr<strong>an</strong>e</strong>’s <strong>an</strong>swer to selecting this indoor coil for their matched system. Thethis environmental issue is the all-new, all-aluminum innovative adv<strong>an</strong>cement <strong>an</strong>d precision engineeringComfort coil—the only one of its kind in the industry. of the aluminum Comfort coil will be a money-savingBy being corrosion <strong>an</strong>d rust resist<strong>an</strong>t, the aluminum investment for your customer <strong>an</strong>d a profit-earningComfort coil promises your customers the highest sale for you.Reliable perform<strong>an</strong>ceCle<strong>an</strong>er airComfort ControlEfficient operationPrecision engineering, designinnovation <strong>an</strong>d rigorous testing forreliable, long-lasting perform<strong>an</strong>ce<strong>an</strong>d durability.Add a TRANE Cle<strong>an</strong>Effects TM air cle<strong>an</strong>er toremove up to 99.98% of airborne allergensfrom the filtered air for a cle<strong>an</strong>er,more comfortable home.Give your customers bettercomfort control with a <strong>Tr<strong>an</strong>e</strong> digitalor programmable thermostat.The Comfort coil increases efficiencyto help subst<strong>an</strong>tially lower customers’home utility costs.


TRANE ALUMINUM HIGH EFFICIENCY COMFORT TM COILSTR ALCOILS54361Foil insulation100% foil-backed insulation provides easy cle<strong>an</strong>ing forcle<strong>an</strong>er air, reduced sound operation.Two-way, sloped, non-corrosive drain p<strong>an</strong>Prevents st<strong>an</strong>ding water <strong>an</strong>d reduces bacteria growth whichsignific<strong>an</strong>tly improves indoor air quality. M<strong>an</strong>ufactured withnon-corrosive material to prevent rust.Easy-access inner coil p<strong>an</strong>elMakes cle<strong>an</strong>ing <strong>an</strong>d servicing easier which in turn leadsto higher efficiency <strong>an</strong>d longer life. Improves installation<strong>an</strong>d service time.1 42356Baked-on high gloss finishProvides increased protection from rust <strong>an</strong>d corrosion.Matches furnace in color.External service portTo maintain higher perform<strong>an</strong>ce with quicker <strong>an</strong>d easierserviceability. Allows indoor evacuation <strong>an</strong>d charging.Decreases service <strong>an</strong>d unit down time.TXV with mech<strong>an</strong>ical fittingsAllows replacement without brazing.2Features <strong>an</strong>d components may vary by model <strong>an</strong>dare shown for illustration purposes only.HI-EFFICIENCY CASED UPFLOW/DOWNFLOW/HORIZONTAL LEFT (Refriger<strong>an</strong>t R-22)NominalUncratedCap. Clg. Ref. Dimensions (in.)Model (BTUH) Type Control Cased H W D2TXCB025AS3HCA 24,000 A HP TXV-NB Full 17.6 17.5 21.52TXCB031AS3HCA 30,000 A HP TXV-NB Full 22.6 17.5 21.52TXCB036AS3HCA 36,000 A HP TXV-NB Full 26.9 17.5 21.52TXCC037AS3HCA 37,000 A HP TXV-NB Full 26.9 21.0 21.52TXCC054AS3HCA 54,000 A HP TXV-NB Full 30.1 21.0 21.52TXCD065AS3HCA 60,000 A HP TXV-NB Full 30.1 24.5 21.5HI-EFFICIENCY CASED UPFLOW/DOWNFLOW/HORIZONTAL LEFT (Refriger<strong>an</strong>t R-410A)4TXCB025AS3HCA 24,000 A HP TXV-NB Full 17.6 17.5 21.54TXCB031AS3HCA 30,000 A HP TXV-NB Full 22.6 17.5 21.54TXCB036AS3HCA 36,000 A HP TXV-NB Full 26.9 17.5 21.54TXCC037AS3HCA 37,000 A HP TXV-NB Full 26.9 21.0 21.54TXCC054AS3HCA 54,000 A HP TXV-NB Full 30.1 21.0 21.54TXCD065AS3HCA 60,000 A HP TXV-NB Full 30.1 24.5 21.5As part of our continuos product improvement, <strong>Tr<strong>an</strong>e</strong> reserves the right to ch<strong>an</strong>ge specifications <strong>an</strong>d design without notice.Warr<strong>an</strong>ties generate additional income.<strong>Tr<strong>an</strong>e</strong> extended warr<strong>an</strong>ties create additional income. Selling extendedwarr<strong>an</strong>ties is <strong>an</strong>other way to protect your customers <strong>an</strong>d generatefuture business.It all adds up to a stellar reputation.We know that when you recommend our products to your loyal customersyou are placing your livelihood <strong>an</strong>d reputation in our h<strong>an</strong>ds. Wesalute your expertise in delivering <strong>Tr<strong>an</strong>e</strong> technology <strong>an</strong>d innovation toyour customers—making their homes a better place for living. You arethe reason we c<strong>an</strong> say “expect more from <strong>Tr<strong>an</strong>e</strong>.”tr<strong>an</strong>e.com© 2005 TRANE ® a business of Americ<strong>an</strong> St<strong>an</strong>dard Comp<strong>an</strong>ies. All rights reserved. Pub. No. ALCOILS-01 09/05


XV, XL, XT, XR, XB 90 ConvertibleGas Furnaces Airflow DirectionsNote: Coil access is opposite of furnace.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.FUR-1 Effective 1/1/06


XV, XL 90Convertible Gas FurnacesAirflow Directions:Downflow models when placed in horizontal position provide left to right airflow.Upflow models when placed in horizontal position provide right to left airflow.XV 90 Direct/Non- Direct VentTable FUR-2-A — XV Direct/Non-Direct Vent, Two-Stage, One or Two Pipe, Variable Speed, Upflow/HorizontalCondensing Gas Furnace (115/1/60)Airflow Flue Uncrated ShippingUnit In Output (Btuh) ICS1 Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* SizesTUY060R9V3W 3 56,000 37,000 93.0 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 156 15 17 x 25 x 1TUY080R9V3W 3 73,000 48,000 92.5 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 168 15 17 x 25 x 1TUY100R9V4W 4 93,000 60,000 93.0 2 1 /2-3 Silicon Nitride 40 x 21 x 28 197 15 20 x 25 x 1TUY120R9V5W 5 112,000 72,000 92.5 3 Only Silicon Nitride 40 x 24 1 /2 x 28 206 15 24 x 25 x 1Note: Variable speed XV90 furnaces should not be twinned <strong>an</strong>d are not approved for twinning applications.XV 90 Direct/Non- Direct VentTable FUR-2-B — XV Direct/Non-Direct Vent, Two-Stage, One or Two Pipe, Variable Speed, Downflow/Horizontal Condensing Gas Furnace (115/1/60)Airflow Flue Uncrated ShippingUnit In Output (Btuh) ICS1 Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* SizesTDY060R9V3W 3 56,000 36,000 92.0 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 160 15 (2) 14 x 20 x 1TDY080R9V3W 3 74,000 48,000 92.5 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 168 15 (2) 14 x 20 x 1TDY100R9V4W 4 94,000 60,000 93.0 2 1 /2-3 Silicon Nitride 40 x 21 x 28 185 15 (2) 16 x 20 x 1TDY120R9V5W 5 112,000 72,000 92.5 3 Only Silicon Nitride 40 x 24 1 /2 x 28 206 15 (2) 16 x 20 x 1Note: Variable speed XV90 furnaces should not be twinned <strong>an</strong>d are not approved for twinning applications.XL 90 Direct/Non-Direct VentTable FUR-2-C — XL 90 Direct/Non-Direct Vent, Two Stage, One or Two Pipe, Upflow/HorizontalCondensing Gas Furnace (115/1/60)Airflow Flue Uncrated ShippingUnit In Output (Btuh) ICS1 Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* SizesTUX060R936W 3 56,000 36,000 93.0 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 156 15 17 x 25 x 1TUX080R942W 3 1 /2 73,000 48,000 92.5 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 168 15 17 x 25 x 1TUX100R948W 4 93,000 60,000 93.0 2 1 /2-3 Silicon Nitride 40 x 21x 28 197 15 20 x 25 x 1TUX120R960W 5 112,000 72,000 92.5 3 Only Silicon Nitride 40 x 24 1 /2 x 28 206 15 24 x 25 x 1XL 90 Direct/Non-Direct VentTable FUR-2-D — XL 90 Direct/Non-Direct Vent, Two Stage, One or Two Pipe, Downflow/HorizontalCondensing Gas Furnace (115/1/60)Airflow Flue Uncrated ShippingUnit In Output (Btuh) ICS1 Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* SizesTDX060R936W 3 55,000 36,000 92.0 2-3 Silicon Nitride 40 x 17 1 /2 x 28 160 15 (2) 14 x 20 x 1TDX080R942W 3 1 /2 74,000 48,000 92.5 2-3 Silicon Nitride 40 x 17 1 /2 x 28 168 20 (2) 14 x 20 x 1TDX100R948W 4 93,000 60,000 93.0 2 1 /2-3 Silicon Nitride 40 x 21 x 28 185 15 (2) 16 x 20 x 1TDX120R960W 5 111,000 72,000 92.5 3 Only Silicon Nitride 40 x 24 1 /2 x 28 206 15 (2) 16 x 20 x 11 Isolated Combustion System.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.Effective 1/1/06FUR-2For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


XT, XR 90Convertible Gas FurnacesTable FUR-3-A — XT 90 Direct/Non-Direct Vent, Single-Stage, One or Two Pipe, Upflow/HorizontalCondensing Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated ShippingUnit In Output ICS1 Size Ignition Dimensions (in.) Weight Max Filter**Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* SizesTUX1B040A9H21A 2 38,000 92.1 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 139 15 17 x 25 x 1TUX1B060A9H31A 3 56,000 92.1 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 150 15 17 x 25 x 1TUX1B080A9H31A 3 74,000 92.1 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 158 15 17 x 25 x 1TUX1C100A9H41A 4 94,000 92.1 2 1 /2, 3 Silicon Nitride 40 x 21 x 28 171 20 20 x 25 x 1TUX1D120A9H51A 5 113,000 92.1 2 1 /2, 3 Silicon Nitride 40 x 24 1 /2 x 28 205 20 24 x 25 x 1XT 90 Direct/Non- Direct VentTable FUR-3-B — XT 90 Direct/Non-Direct Vent, Single-Stage, One or Two Pipe, Downflow/HorizontalCondensing Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated ShippingUnit In Output ICS1 Size Ignition Dimensions (in.) Weight Max Filter**Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* SizesTDX1B040A9H21A 3 38,000 91.0 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 145 15 (2) 14 x 20 x 1TDX1B060A9H31A 3 56,000 91.0 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 155 15 (2) 14 x 20 x 1TDX1B080A9H31A 3 74,000 91.0 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 168 15 (2) 14 x 20 x 1TDX1C100A9H41A 4 94,000 91.0 2 1 /2, 3 Silicon Nitride 40 x 21 x 28 185 20 (2) 16 x 20 x 1TDX1D120A9H51A 5 112,000 91.0 2 1 /2, 3 Silicon Nitride 40 x 24 1 /2 x 28 206 20 (2) 16 x 20 x 1XR 90 Direct VentTable FUR-3-C — XR 90 Direct/Non-Direct Vent, Single Stage, One or Two Pipe, Upflow/HorizontalCondensing Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated ShippingUnit In Output ICS1 Size Ignition Dimensions (in.) Weight Max Filter**Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* SizesTUX1B040A9241A 2 38,000 92.1 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 139 15 17 x 25 x 1TUX1B060A9361A 3 56,000 92.1 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 150 15 17 x 25 x 1TUX1B080A9421A 3 1 /2 74,000 92.1 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 158 15 17 x 25 x 1TUX1C080A9601A 5 76,000 92.1 2, 2 1 /2, 3 Silicon Nitride 40 x 21 x 28 171 15 20 x 25 x 1TUX1C100A9481A 4 94,000 92.1 2 1 /2-3 Silicon Nitride 40 x 21 x 28 171 20 20 x 25 x 1TUX1D100A9601A 5 93,000 92.1 2 1 /2-3 Silicon Nitride 40 x 24 1 /2 x 28 197 15 24 x 25 x 1TUX1D120A9601A 5 113,000 92.1 2 1 /2-3 Silicon Nitride 40 x 24 1 /2 x 28 205 15 24 x 25 x 1Table FUR-3-D — XR 90 Direct/Non-Direct Vent, Single Stage, One or Two Pipe, Downflow/HorizontalCondensing Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated ShippingUnit In Output ICS1 Size Ignition Dimensions (in.) Weight Max Filter**Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* SizesTDX1B040A9241A 2 38,000 91.0 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 145 15 (2) 14 x 20 x 1TDX1B060A9361A 3 56,000 91.0 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 155 15 (2) 14 x 20 x 1TDX1B080A9421A 3 1 /2 74,000 91.0 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 168 20 (2) 14 x 20 x 1TDX1C100A9481A 4 94,000 91.0 2 1 /2-3 Silicon Nitride 40 x 21 x 28 185 20 (2) 16 x 20 x 1TDX1D120A9601A 5 112,000 91.0 2 1 /2-3 Silicon Nitride 40 x 24 1 /2 x 28 206 15 (2) 16 x 20 x 11 Isolated Combustion System.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.** Filters are not shipped with furnace.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.FUR-3 Effective 1/1/06


XR, XB 90Convertible Gas FurnacesTable FUR-4-A — XR 90 Direct/Non-Direct Vent, Single Stage, One or Two Pipe, Upflow/HorizontalCondensing Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated ShippingUnit In Output ICS1 Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* SizesTUX040C924D 2 38,000 92.1 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 139 15 17 x 25 x 1TUX060C936D 3 56,000 92.1 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 150 15 17 x 25 x 1PHASED OUTTUX080C942D 3 1 /2 74,000 92.1 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 158 15 17 x 25 x 1TUX080C960D 5 76,000 92.1 2, 2 1 /2, 3 Silicon Nitride 40 x 21 x 28 171 15 20 x 25 x 1TUX100C948D 4 94,000 92.1 2 1 /2-3 Silicon Nitride 40 x 21 x 28 171 20 20 x 25 x 1TUX100C960D 5 93,000 92.1 2 1 /2-3 Silicon Nitride 40 x 24 1 /2 x 28 197 15 24 x 25 x 1TUX120C960D 5 113,000 92.1 2 1 /2-3 Silicon Nitride 40 x 24 1 /2 x 28 205 15 24 x 25 x 1XR 90 Direct VentTable FUR-4-B — XR 90 Direct/Non-Direct Vent, Single Stage, One or Two Pipe, Downflow/HorizontalCondensing Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated ShippingUnit In Output ICS1 Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* SizesTDX040C924D 2 38,000 91.0 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 145 15 (2) 14 x 20 x 1PHASED OUTTDX060C936D 3 56,000 91.0 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 155 15 (2) 14 x 20 x 1TDX080C942D 3 1 /2 74,000 91.0 2, 2 1 /2, 3 Silicon Nitride 40 x 17 1 /2 x 28 168 20 (2) 14 x 20 x 1TDX100C948D 4 94,000 91.0 2 1 /2-3 Silicon Nitride 40 x 21 x 28 185 20 (2) 16 x 20 x 1TDX120C960D 5 112,000 91.0 2 1 /2-3 Silicon Nitride 40 x 24 1 /2 x 28 206 15 (2) 16 x 20 x 1Table FUR-4-C — XB 90 Single Stage, Single Pipe, Upflow/Horizontal Left Condensing Gas Furnace(115/1/60)Airflow Nominal Flue Uncrated ShippingUnit In Output Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* SizesTUC040C924B 2 37,000 92.1 2, 2 1 /2, 3 Silicon Carbide 40 x 17 1 /2 x 28 139 15 17 x 25 x 1TUC060C936B 3 56,000 92.1 2, 2 1 /2, 3 Silicon Carbide 40 x 17 1 /2 x 28 150 15 17 x 25 x 1TUC080C942B 3 1 /2 74,000 92.1 2, 2 1 /2, 3 Silicon Carbide 40 x 17 1 /2 x 28 158 15 17 x 25 x 1TUC100C948B 4 94,000 92.1 2, 2 1 /2, 3 Silicon Carbide 40 x 21 x 28 171 20 20 x 25 x 1TUC100C960B 5 93,000 92.1 2, 2 1 /2, 3 Silicon Carbide 40 x 24 1 /2 x 28 197 15 24 x 25 x 1TUC120C960B 5 113,000 92.1 3 Only Silicon Carbide 40 x 24 1 /2 x 28 205 15 24 x 25 x 1XB 90Table FUR-4-D— XB 90 Single Stage, Single Pipe, Downflow/Horizontal Right Condensing Gas Furnace(115/1/60)Airflow Nominal Flue Uncrated ShippingUnit In Output Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* SizesTDC040C924B 2 38,000 91.0 2, 2 1 /2, 3 Silicon Carbide 40 x 17 1 /2 x 28 145 15 (2) 14 x 20 x 1TDC060C936B 3 56,000 91.0 2, 2 1 /2, 3 Silicon Carbide 40 x 17 1 /2 x 28 155 15 (2) 14 x 20 x 1TDC080C942B 3 1 /2 74,000 91.0 2, 2 1 /2, 3 Silicon Carbide 40 x 17 1 /2 x 28 168 20 (2) 14 x 20 x 1TDC100C948B 4 93,000 91.0 2, 2 1 /2, 3 Silicon Carbide 40 x 21 x 28 185 20 (2) 16 x 20 x 1TDC120C960B 5 112,000 91.0 3 Only Silicon Carbide 40 x 24 1 /2 x 28 206 15 (2) 16 x 20 x 11 Isolated Combustion System.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.Effective 1/1/06FUR-4For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


XV, XL, XT, XR, XB 90Convertible Gas FurnacesXV 90 XL 90 XT 90 XR 90 XR 90 XB 90Airflow Directions:Downflow models when placed in horizontal position provide leftTUY/TDY TUX-R/TDX-R TUX1/TDX1 TUX1/TDX1 TUX/TDX-C TUC/TDCto right airflow. Upflow models when placed in horizontal position 2 Stage/1-2 Pipe 2 Stage 1 Stage 1 Stage 1 Stage 1 Stageprovide right to left airflow.Variable Speed 1 or 2 Pipe 1 or 2 Pipe 1or 2 Pipe 1or 2 Pipe 1 PipeDirect/Non Direct/Non High Efficiency Direct/Non Direct/Non NonDirect Vent Direct Vent Direct/Non Direct Vent Direct Vent DirectVentTable FUR-5-A — FeaturesDirect Vent• Comfort”R” enh<strong>an</strong>ced mode (cooling) ............................ ✔ — — — — —• Adjustable heating f<strong>an</strong> off timing ........................................... ✔ ✔ ✔ ✔ ✔ ✔• Alternate bottom/left/right return air (upflow only) ................... ✔ ✔ ✔ ✔ ✔ ✔• Blower door safety switch .................................................... ✔ ✔ ✔ ✔ ✔ ✔• Bottom p<strong>an</strong>el ..................................................................... ✔ ✔ ✔ ✔ ✔ ✔• Cle<strong>an</strong>able/Reusable high velocity filters ................................ ✔ ✔ — — ✔ —• Complete front service access ............................................ ✔ ✔ ✔ ✔ ✔ ✔• Direct drive, 4-speed motor ................................................. — ✔ — ✔ ✔ ✔• Direct drive high efficiency, 4 speed motor ............................ — — ✔ — — —• Direct drive, GE ICM variable speed blower motor ................. ✔ — — — — —• Downflow horizontal right (downflow models only) ................. TDY TDX TDX TDX TDX TDC• Dual PVC pipe venting (1 or 2 pipe option) ............................ ✔ ✔ ✔ ✔ ✔ —• Single PVC pipe venting (1 pipe only) ................................... — — — — — ✔• Dual solenoid combination gas valve <strong>an</strong>d regulator ............... ✔ ✔ ✔ ✔ ✔ ✔• Gasketed blower door ......................................................... ✔ ✔ ✔ ✔ ✔ —• Heavy gauge reinforced wrap-around steel cabinet ............... ✔ ✔ ✔ ✔ ✔ ✔• Hinged blower door ............................................................ ✔ ✔ ✔ ✔ ✔ —• Humidifier/EAC hook-up capability (factory wired) ................. ✔ ✔ ✔ ✔ ✔ ✔• Inner blower door p<strong>an</strong>el, downflow models only .................... TDY TDX TDX TDX TDX TDC• Insulated blower compartment 4 sides ................................. ✔ ✔ ✔ ✔ ✔ —• Cle<strong>an</strong>able Filters ................................................................ ✔ ✔ — — ✔ —• Internal filter rack ................................................................ ✔ ✔ — — ✔ —• Left/right condensate drain capability in vertical application ..... ✔ ✔ — ✔ ✔ ✔• Lite Port/Stored diagnotics .................................................. ✔ ✔ — — — —• Mobile home approved w/BAYMFGH100A ........................... ✔ ✔ ✔ ✔ ✔ —• Multi-port in shot burners ..................................................... ✔ ✔ ✔ ✔ ✔ ✔• Painted cabinet single color ................................................. — — — — — ✔• Painted cabinet two tone color ............................................. ✔ ✔ ✔ ✔ ✔ —• Service diagnostic capabilities ............................................. ✔ ✔ ✔ ✔ ✔ ✔• Side out blower assembly ................................................... ✔ ✔ ✔ ✔ ✔ ✔• Side return duct starter tabs ................................................ ✔ ✔ ✔ ✔ ✔ ✔• Silicon Carbide hot surface igniter with adaptive heat up ........ — — — — — ✔• Silicon Nitride hot surface igniter with adaptive heat up ........... ✔ ✔ ✔ ✔ ✔ —• Single wire twinning ............................................................ — ✔ ✔ ✔ ✔ —• Solid burner door (quiet operation) ....................................... ✔ ✔ ✔ ✔ ✔ —• 20 gauge aluminized steel heat exch<strong>an</strong>ger ........................... ✔ ✔ ✔ ✔ ✔ ✔• 24 volt secondary fuse ........................................................ ✔ ✔ ✔ ✔ ✔ ✔• Two heating blower speeds ................................................. ✔ ✔ — — — —• Two-stage gas valve ........................................................... ✔ ✔ — — — —• Type 29-4C stainless steel secondary heat exch<strong>an</strong>ger ....... ✔ ✔ ✔ ✔ ✔ ✔• Upflow horizontal left (upflow models only) ............................ TUY TUX TUX TUX TUX TUC• Variable Speed venter motor ............................................... ✔ ✔ — — — —• Limited lifetime heat exch<strong>an</strong>ger warr<strong>an</strong>ty to original owner <strong>an</strong>d ✔ ✔ ✔ ✔ ✔ ✔20-years to succeeding homeowner from date of installation• 5-year limited warr<strong>an</strong>ty on parts* .......................................... ✔ ✔ ✔ ✔ ✔ ✔NOTE: Variable speed XV90 furnaces should not be twinned <strong>an</strong>d are not approved for twinning applications.PHASED OUTFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.FUR-5 Effective 1/1/06


Airflow Directions:Downflow models when placed in horizontal position provide leftto right airflow. Upflow models when placed in horizontal positionprovide right to left airflow.XV, XL, XT, XR, XB 90Convertible Gas FurnacesXV 90 XL 90 XT 90 XR 90 XR 90 XB 90TUY/TDY TUX-R/TDX-R TUX1/TDX1 TUX1/TDX1 TUX/TDX-C TUC/TDC2 Stage/1-2 Pipe 2 Stage 1 Stage 1 Stage 1 Stage 1 StageVariable Speed 1 or 2 Pipe 1 or 2 Pipe 1or 2 Pipe 1or 2 Pipe 1 PipeDirect/Non Direct/Non Direct/Non Direct/Non Direct/Non NonTable FUR-6-A — Optional Accessories Direct Vent Direct Vent Direct Vent Direct Vent Direct Vent DirectVentBAY69X146 ........... Horizontal vent cap (Noryl) ............................ — — — — — ✔BAY69X147 ........... Wall mount fl<strong>an</strong>ge – 3" .................................. — — ✔ ✔ ✔ ✔BAY69X148 ........... Wall mount fl<strong>an</strong>ge – 2" .................................. — — ✔ ✔ ✔ ✔BAYBASE205 ........ Downflow subbase ....................................... ✔ ✔ ✔ ✔ ✔ ✔BAYFLTR200 ......... External side filter rack .................................. ✔ ✔ ✔ ✔ ✔ ✔BAYFLTR203 ........ Filter kit horiz conversion ............................. ✔ ✔ — — ✔ ✔for 17.5" cabinetBAYFLTR204 ........ Filter kit horiz conversion ............................. ✔ ✔ — — ✔ ✔for 21" cabinetBAYFLTR205 ........ Filter kit horiz conversion ............................ ✔ ✔ — — ✔ ✔for 24.5" cabinetBAYFLTR206 ........ Filter kit ....................................................... — — ✔ ✔ ✔ ✔BAYFLTR3171 .... Cle<strong>an</strong>able filter for 17.5" ............................. ✔ ✔ ✔ ✔ ✔ ✔cabinet upflow onlyBAYFLTR3211 .... Cle<strong>an</strong>able filter for 21" ............................... ✔ ✔ ✔ ✔ ✔ ✔cabinet upflow onlyBAYFLTR3241 .... Cle<strong>an</strong>able filter for 24.5" ............................. ✔ ✔ ✔ ✔ ✔ ✔cabinet upflow onlyBAYLPKT210B ..... Prop<strong>an</strong>e conversion kit .................................. ✔ ✔ ✔ ✔ ✔ ✔BAYLPSS210B .... LP Kit with Stainless ................................... ✔ ✔ ✔ ✔ ✔ ✔Steel BurnersBAYMFGH100A .... M<strong>an</strong>ufactured/mobile .................................. ✔ ✔ ✔ ✔ ✔ —home kitBAYRACK960A .... Filter rack kit for upflow ............................... TUY TUX ✔ TUX TUX TUCmodels only (internal)23BAYVENT100A ..... Concentric vent kit for 2, ............................. ✔ ✔ ✔ ✔ ✔ —2 1 /2 <strong>an</strong>d 3" vent systemPHASED OUTBAYVENT200B ..... Sidewall vent Terminator ............................. ✔ ✔ ✔ ✔ ✔ —Kit for Direct vent furnaces1 Contains one (1) high velocity filter.2 Internal filter rack for side or bottom return air.3 Includes 17" Cle<strong>an</strong>able Filter.NOTE: Variable Speed XV90 Furnaces should not be twinned <strong>an</strong>d are not approved for twinning applications.Special Use Furnace AccessoriesTable FUR-6-B — High Altitude Pressure Switch 90%ModelShippingNumber Description Used With WeightBAYHALT225 1 Switch TUC0 80,100C948,120C, TDC080,120C 2BAYHALT226 1 Switch TUC,TDC060C 2BAYHALT227 1 Switch TUC100C948 2BAYHALT228 1 Switch TUC/TDC040C 2BAYHALT230 1 Switch TUX/TDX040C, TUX1B040,D100/TDX1B040 2BAYHALT231 1 Switch TUX060C, TUX1060C 2BAYHALT232 1 Switch TUX080C, TUX1B080C 2BAYHALT233 1 Switch TUX100,120C/TDX080,120C, TUX1C100,D120/TDX1B080,D120 2BAYHALT234 1 Switch TDX100C, TDX1C100 2BAYHALT241 1 Switch TDX060C, TDX1B060 2BAYHALT245 2 Switches TDX/TUX/TDY/TUY060-R 2BAYHALT246 2 Switches TDX/TUX/TDY/TUY080,100-R 2BAYHALT247 2 Switches TDX/TUX/TDY/TUY120-R 2BAYSWT01AMALTA 1 Switch TUX/TDX120C,100C948,TUX/TDX1D120-9601,1C100-9481 2BonnetSwitchTAYPLUS103ATable FUR-6-C — Dual Fuel Heat Pump Control Kit12Model Number Case Height Used WithTAYPLUS103A ............. Heat Pump Control Kit .............. Gas, LP., Oil <strong>an</strong>d Electric FurnacesTAYSTAT250B .............. Outdoor Thermostat ................. TAYPLUS103A for Restricted ModeTHT1248 ....................... Bonnet Switch .......................... Oil Furnaces Only (Order Separately)1 Factory wired for non-restricted mode, c<strong>an</strong> be wired for restricted mode.2 Applicable for all furnaces with 35 VA or larger low voltage tr<strong>an</strong>sformer (separate high voltage power not required).Effective 1/1/06FUR-6For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


XV, XL, XT, XR, XB 80 ConvertibleGas Furnaces Airflow DirectionsFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.FUR-7 Effective 1/1/06


XV, XL 80, ConvertibleGas FurnacesXV 80XV 80XL 80XL 80Table FUR-8-A — XV 80 Variable Speed, Two-Stage, Upflow/Horizontal Left or Right Induced Draft GasFurnace (115/1/60)Airflow Flue Uncrated ShippingUnit In Output (Btuh) Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* SizesTUD060R9V3K 3 48,000 31,200 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 136 15 17 x 25 x 1TUD080R9V3K 3 64,000 41,600 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 142 15 17 x 25 x 1TUD080R9V4K 4 64,000 41,600 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 17 x 25 x 1TUD100R9V3K 3 80,000 52,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 142 15 17 x 25 x 1TUD100R9V5K 5 79,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 20 x 25 x 1TUD120R9V5K 5 97,000 62,400 80.0 4 Silicon Nitride 40 x 24 1 /2 x 28 186 15 24 x 25 x 1TUD140R9V5K 5 111,000 72,800 80.0 4 Silicon Nitride 40 x 24 1 /2 x 28 197 15 24 x 25 x 1NOTE: Variable speed XV80 furnaces should not be twinned <strong>an</strong>d are not approved for twinning applications.Table FUR-8-B — XV 80 Variable Speed, Two-Stage, Downflow/Horizontal Left or Right Induced Draft GasFurnace (115/1/60)Airflow Flue Uncrated ShippingUnit In Output (Btuh) Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* SizesTDD060R9V3F 3 48,000 31,200 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 140 15 (2) 14 x 20 x 1TDD080R9V3F 3 63,000 41,600 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 146 15 (2) 14 x 20 x 1TDD100R9V5F 5 81,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 (2) 16 x 20 x 1TDD120R9V5F 5 95,000 62,400 80.0 4 Silicon Nitride 40 x 24 1 /2 x 28 197 15 (2) 16 x 20 x 1NOTE: Variable speed XV80 furnaces should not be twinned <strong>an</strong>d are not approved for twinning applications.Table FUR-8-C — XL 80 Two-Stage, Upflow/Horizontal, Left or Right Induced Draft Gas Furnace (115/1/60)Airflow Flue Uncrated ShippingUnit In Output (Btuh) Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* SizesTUD040R924K 2 32,000 20,800 80.0 4 Silicon Nitride 40 x 14 1 /2 x 28 119 15 17 x 25 x 1**TUD060R936K 3 47,000 31,200 80.0 4 Silicon Nitride 40 x 14 1 /2 x 28 127 15 17 x 25 x 1**TUD060R937K 3 47,000 31,200 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 137 15 17 x 25 x 1TUD080R936K 3 63,000 41,600 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 142 15 17 x 25 x 1TUD080R948K 4 63,000 41,600 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 142 15 17 x 25 x 1TUD100R936K 3 79,000 52,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 151 15 17 x 25 x 1TUD100R948K 4 79,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1TUD100R960K 5 80,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1TUD100R961K 5 80,000 52,000 80.0 4 Silicon Nitride 40 x 24 1 /2 x 28 175 20 24 x 25 x 1TUD120R954K 5 95,000 62,400 80.0 4 Silicon Nitride 40 x 21 x 28 176 20 20 x 25 x 1TUD120R960K 5 95,000 62,400 80.0 4 Silicon Nitride 40 x 24 1 /2 x 28 186 20 24 x 25 x 1TUD140R960K 5 112,000 72,800 80.0 4 Silicon Nitride 40 x 24 1 /2 x 28 192 20 24 x 25 x 1Table FUR-8-D — XL 80 Two-Stage, Downflow/Horizontal Left or Right Induced Draft (115/1/60)Airflow Flue Uncrated ShippingUnit In Output (Btuh) Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* SizesTDD040R924F 2 32,000 20,800 80.0 4 Silicon Nitride 40 x 14 1 /2 x 28 125 15 (2) 14 x 20 x 1TDD060R936F 3 47,000 31,200 80.0 4 Silicon Nitride 40 x 14 1 /2 x 28 135 15 (2) 14 x 20 x 1TDD060R937F 3 47,000 31,200 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 147 15 (2) 14 x 20 x 1TDD080R936F 3 64,000 41,600 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 152 15 (2) 14 x 20 x 1TDD100R945F 4 79,000 52,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 157 15 (2) 14 x 20 x 1TDD100R948F 4 79,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 (2) 16 x 20 x 1TDD100R960F 5 81,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 168 15 (2) 16 x 20 x 1TDD120R960F 5 96,000 62,400 80.0 4 Silicon Nitride 40 x 24 1 /2 x 28 189 15 (2) 16 x 20 x 1TDD140R960F 5 113,000 72,800 80.0 4 Silicon Nitride 40 x 24 1 /2 x 28 196 15 (2) 16 x 20 x 1* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.** Ship with filter sizes. May be trimmed for bottom return.Effective 1/1/06FUR-8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


XT, XR 80Convertible Gas FurnacesXT 80UpflowXT 80DownflowXR 80XR 80Table FUR-9-A — XT 80 Single Stage, Upflow Horizontal, Left or Right Induced Draft Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated ShippingUnit In Output Size Ignition Dimensions (in.) Weight Max Filter**Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* SizesTUD1A040A9H21A 2 32,000 80 4 Silicon Nitride 40 x 14 1 /2 x 28 119 15 17 x 25 x 1TUD1B060A9H31A 3 47,000 80 4 Silicon Nitride 40 x 17 1 /2 x 28 127 15 17 x 25 x 1TUD1B080A9H31A 3 63,000 80 4 Silicon Nitride 40 x 17 1 /2 x 28 142 15 17 x 25 x 1TUD1C080A9H41A 4 64,000 80 4 Silicon Nitride 40 x 21 x 28 142 20 20 x 25 x 1TUD1B100A9H31A 3 79,000 80 4 Silicon Nitride 40 x 17 1 /2 x 28 151 20 17 x 25 x 1TUD1C100A9H51A 5 79,000 80 4 Silicon Nitride 40 x 21 x 28 162 20 20 x 25 x 1TUD1D120A9H51A 5 96,000 80 4 Silicon Nitride 40 x 24 1 /2 x 28 186 20 24 x 25 x 1TUD1D140A9H51A 5 111,000 80 4 Silicon Nitride 40 x 24 1 /2 x 28 193 20 24 x 25 x 1Table FUR-9-B — XT 80 Single Stage, Downflow Horizontal, Left or Right Induced Draft Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated ShippingUnit In Output Size Ignition Dimensions (in.) Weight Max Filter**Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* SizesTDD1B060A9H31A 3 48,000 80 4 Silicon Nitride 40 x 17 1 /2 x 28 139 15 (2) 14 x 20 x 1TDD1B080A9H31A 3 64,000 80 4 Silicon Nitride 40 x 17 1 /2 x 28 146 15 (2) 14 x 20 x 1TDD1C100A9H51A 5 81,000 80 4 Silicon Nitride 40 x 21 x 28 167 20 (2) 16 x 20 x 1TDD1D120A9H51A 5 96,000 80 4 Silicon Nitride 40 x 24 1 /2 x 28 189 20 (2) 16 x 20 x 1Table FUR-9-C — XR 80 Single Stage, Upflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated ShippingUnit In Output Size Ignition Dimensions (in.) Weight Max Filter**Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* SizesTUD1A040A9241A 2 32,000 80.0 4 Silicon Nitride 40 x 14 1 /2 x 28 119 15 17 x 25 x 1TUD1A040A9301A 2 1 /2 32,000 80.0 4 Silicon Nitride 40 x 14 1 /2 x 28 122 15 17 x 25 x 1TUD1A060A9241A 2 47,000 80.0 4 Silicon Nitride 40 x 14 1 /2 x 28 124 15 17 x 25 x 1TUD1A060A9361A 3 47,000 80.0 4 Silicon Nitride 40 x 14 1 /2 x 28 127 15 17 x 25 x 1TUD1B060A9361A 3 47,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 137 15 17 x 25 x 1TUD1B080A9241A 2 64,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 139 15 17 x 25 x 1TUD1B080A9361A 3 63,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 142 15 17 x 25 x 1TUD1B080A9481A 4 64,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 142 15 17 x 25 x 1TUD1C080A9601A 5 64,000 80.0 4 Silicon Nitride 40 x 21 x 28 154 15 20 x 25 x 1TUD1C100A9361A 3 79,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 151 15 17 x 25 x 1TUD1C100A9451A 4 80,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 153 15 17 x 25 x 1TUD1C100A9481A 4 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1TUD1C100A9601A 5 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 20 20 x 25 x 1TUD1D100A9721A 6 80,000 80.0 4 Silicon Nitride 40 x 24 1 /2 x 28 175 20 24 x 25 x 1TUD1C120A9541A 5 96,000 80.0 4 Silicon Nitride 40 x 21 x 28 176 20 20 x 25 x 1TUD1D120A9601A 5 96,000 80.0 4 Silicon Nitride 40 x 24 1 /2 x 28 186 20 24 x 25 x 1TUD1D140A9601A 5 111,000 80.0 4 Silicon Nitride 40 x 24 1 /2 x 28 193 20 24 x 25 x 1Table FUR-9-D — XR 80 Single Stage, Downflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated ShippingUnit In Output Size Ignition Dimensions (in.) Weight Max Filter**Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* SizesTDD1A040A9241A 2 31,000 78.0 4 Silicon Nitride 40 x 14 1 /2 x 28 119 15 (2) 14 x 20 x 1TDD1A060A9241A 2 48,000 80.0 4 Silicon Nitride 40 x 14 1 /2 x 28 129 15 (2) 14 x 20 x 1TDD1A060A9361A 3 48,000 80.0 4 Silicon Nitride 40 x 14 1 /2 x 28 129 15 (2) 14 x 20 x 1TDD1B060A9361A 3 48,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 141 15 (2) 14 x 20 x 1TDD1B080A9361A 3 64,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 146 15 (2) 14 x 20 x 1TDD1B080A9451A 4 64,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 146 15 (2) 14 x 20 x 1TDD1B100A9451A 4 80,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 156 15 (2) 14 x 20 x 1TDD1C100A9481A 4 80,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 (2) 16 x 20 x 1TDD1C100A9541A 5 81,000 80.0 4 Silicon Nitride 40 x 21 x 28 167 15 (2) 16 x 20 x 1TDD1C120A9541A 5 96,000 80.0 4 Silicon Nitride 40 x 21 x 28 177 15 (2) 16 x 20 x 1TDD1D120A9601A 5 96,000 80.0 4 Silicon Nitride 40 x 24 1 /2 x 28 189 15 (2) 16 x 20 x 1TDD1D140A9601A 5 113,000 80.0 4 Silicon Nitride 40 x 24 1 /2 x 28 196 15 (2) 16 x 20 x 1* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.** Filters are not shipped with furnace.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.FUR-9 Effective 1/1/06


XR, XB 80Convertible Gas FurnacesXR 80XR 80XB 80Effective 1/1/06Table FUR-10-A — XR 80 Single Stage, Upflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated ShippingUnit In Output Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* SizesTUD040C924K 2 32,000 80.0 4 Silicon Nitride 40 x 14 1 /2 x 28 119 15 17 x 25 x 1TUD040C930K 2 1 /2 32,000 80.0 4 Silicon Nitride 40 x 14 1 /2 x 28 122 15 17 x 25 x 1TUD060C924K 2 47,000 80.0 4 Silicon Nitride 40 x 14 1 /2 x 28 124 15 17 x 25 x 1TUD060C936K 3 47,000 80.0 4 Silicon Nitride 40 x 14 1 /2 x 28 127 15 17 x 25 x 1TUD060C937K 3 47,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 137 15 17 x 25 x 1TUD080C924K 2 64,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 139 15 17 x 25 x 1TUD080C936K 3 63,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 142 15 17 x 25 x 1TUD080C948K 4 64,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 142 15 17 x 25 x 1TUD080C960K 5 64,000 80.0 4 Silicon Nitride 40 x 21 x 28 154 15 20 x 25 x 1PHASED OUTTUD100C936K 3 79,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 151 15 17 x 25 x 1TUD100C945K 4 80,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 153 15 17 x 25 x 1TUD100C948K 4 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1TUD100C960K 5 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 20 20 x 25 x 1TUD100C972K 6 80,000 80.0 4 Silicon Nitride 40 x 24 1 /2 x 28 175 20 24 x 25 x 1TUD120C954K 5 96,000 80.0 4 Silicon Nitride 40 x 21 x 28 176 20 20 x 25 x 1TUD120C960K 5 96,000 80.0 4 Silicon Nitride 40 x 24 1 /2 x 28 186 20 24 x 25 x 1TUD140C960K 5 111,000 80.0 4 Silicon Nitride 40 x 24 1 /2 x 28 193 20 24 x 25 x 1Table FUR-10-B — XR 80 Single Stage, Downflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated ShippingUnit In Output Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* SizesTDD040C924F 2 31,000 78.0 4 Silicon Nitride 40 x 14 1 /2 x 28 119 15 (2) 14 x 20 x 1TDD060C924F 2 48,000 80.0 4 Silicon Nitride 40 x 14 1 /2 x 28 129 15 (2) 14 x 20 x 1TDD060C936F 3 48,000 80.0 4 Silicon Nitride 40 x 14 1 /2 x 28 129 15 (2) 14 x 20 x 1TDD060C937F 3 48,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 141 15 (2) 16 x 20 x 1TDD080C936F 3 64,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 146 15 (2) 14 x 20 x 1TDD080C945F 4 64,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 146 15 (2) 16 x 20 x 1TDD100C945F 4 80,000 80.0 4 Silicon Nitride 40 x 17 1 /2 x 28 156 15 (2) 16 x 20 x 1TDD100C948F 4 80,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 (2) 16 x 20 x 1PHASED OUTTDD100C954F 5 81,000 80.0 4 Silicon Nitride 40 x 21 x 28 167 15 (2) 16 x 20 x 1TDD120C954F 5 96,000 80.0 4 Silicon Nitride 40 x 21 x 28 177 15 (2) 16 x 20 x 1TDD120C960F 5 96,000 80.0 4 Silicon Nitride 40 x 24 1 /2 x 28 189 15 (2) 16 x 20 x 1TDD140C960F 5 113,000 80.0 4 Silicon Nitride 40 x 24 1 /2 x 28 196 15 (2) 16 x 20 x 1Table FUR-10-C — XB 80 Single Stage, Upflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated ShippingUnit In Output Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* SizesTUE040A924L 2 31,000 80.0 4 Silicon Carbide 40 x 14 1 /2 x 28 119 15 16 x 25 x 1TUE060A936L 3 47,000 80.0 4 Silicon Carbide 40 x 14 1 /2 x 28 127 15 16 x 25 x 1TUE060A937L 3 47,000 80.0 4 Silicon Carbide 40 x 17 1 /2 x 28 137 15 17 x 25 x 1TUE080A936L 3 63,000 80.0 4 Silicon Carbide 40 x 17 1 /2 x 28 142 15 17 x 25 x 1TUE080A948L 4 64,000 80.0 4 Silicon Carbide 40 x 17 1 /2 x 28 142 15 17 x 25 x 1TUE100A936L 3 79,000 80.0 4 Silicon Carbide 40 x 17 1 /2 x 28 151 15 17 x 25 x 1TUE100A948L 4 79,000 80.0 4 Silicon Carbide 40 x 21 x 28 162 15 20 x 25 x 1TUE100A960L 5 79,000 80.0 4 Silicon Carbide 40 x 21 x 28 162 15 20 x 25 x 1TUE120A960L 5 96,000 80.0 4 Silicon Carbide 40 x 24 1 /2 x 28 186 20 24 x 25 x 1TUE140A960L 5 111,000 80.0 4 Silicon Carbide 40 x 24 1 /2 x 28 193 20 24 x 25 x 1Table FUR-10-D — XB 80 Single Stage, Downflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated ShippingUnit In Output Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* SizesTDE060A936M 3 48,000 80.0 4 Silicon Carbide 40 x 14 1 /2 x 28 129 15 (2) 14 x 20 x 1TDE060A937M 3 48,000 80.0 4 Silicon Carbide 40 x 17 1 /2 x 28 134 15 (2) 14 x 20 x 1TDE080A945M 4 64,000 80.0 4 Silicon Carbide 40 x 17 1 /2 x 28 146 15 (2) 14 x 20 x 1TDE100A945M 4 80,000 80.0 4 Silicon Carbide 40 x 17 1 /2 x 28 156 15 (2) 14 x 20 x 1TDE100A960M 5 81,000 80.0 4 Silicon Carbide 40 x 21 x 28 167 20 (2) 16 x 20 x 1TDE120A960M 5 96,000 80.0 4 Silicon Carbide 40 x 24 1 /2 x 28 189 20 (2) 16 x 20 x 1*Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.For complete equipment / combinationFUR-10selections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


XV, XL, XT, XR, XB 80Convertible Gas FurnacesAirflow Directions:Downflow models when placed in horizontal position provide leftto right airflow. Upflow models when placed in horizontal positionprovide right to left airflow.XV 80 XL 80 XT 80 XR 80 XR 80 XB 80TUD-R-V-K TUD-R-K TUD1/TDD1 TUD1/TDD1 TUD-C-K TUE/TDETDD-R-V-F 2-Stg. TDD-R-F 1 Stage 1 Stage TDD-C-K 1 StageVariable Speed 2 Stage 1 or 2 Pipe 1 StageTable FUR-11-A — FeaturesHigh Efficiency• Comfort-R enh<strong>an</strong>ced mode (cooling) ............................. ✔ — — — — —• Adjustable heating f<strong>an</strong> off timing .......................................... ✔ ✔ ✔ ✔ ✔ ✔• Adjustable internal filter rack1 ............................................ ✔ ✔ — — ✔ —• Alternate bottom/left/right return air1 ................................... ✔ ✔ ✔ ✔ ✔ ✔• Attractive color accents ...................................................... ✔ ✔ ✔ ✔ ✔ —• Blower door safety switch ................................................... ✔ ✔ ✔ ✔ ✔ ✔• Bottom P<strong>an</strong>el1 ................................................................. ✔ ✔ ✔ ✔ ✔ —• Cle<strong>an</strong>able/reusable high velocity filters ................................ ✔ ✔ — — ✔ —• Common vent capability ..................................................... ✔ ✔ ✔ ✔ ✔ ✔• Complete front service access ........................................... ✔ ✔ ✔ ✔ ✔ ✔• Direct drive, 4-speed motor ................................................ — ✔ ✔ ✔ ✔ ✔• Direct drive,GE ICM variable speed blower motor ................ ✔ — — — — —• Filter ................................................................................. ✔ ✔ — — ✔ —• Gasketed blower door ........................................................ ✔ ✔ ✔ ✔ ✔ —• Heavy gauge reinforced wrap-around steel cabinet .............. ✔ ✔ ✔ ✔ ✔ ✔• Hinged blower door1 ........................................................ ✔ ✔ ✔ ✔ ✔ —• Horizontal left/right without conversion required .................... ✔ ✔ ✔ ✔ ✔ ✔• Humidifier/EAC hook-up capability (factory-wired) ................ ✔ ✔ ✔ ✔ ✔ —• Inner blower door p<strong>an</strong>el on downflow models only ................ ✔ ✔ ✔ ✔ ✔ ✔• Insulated blower compartment 4 sides1 ............................. ✔ ✔ ✔ ✔ ✔ —• Integrated solid state control w/self diagnostics .................... ✔ ✔ ✔ ✔ ✔ ✔• Internal filter rack ............................................................... ✔ ✔ — — ✔ —• Left/right gas connection .................................................... ✔ ✔ ✔ ✔ ✔ ✔• M<strong>an</strong>ual reset flame roll out switches .................................... ✔ ✔ ✔ ✔ ✔ ✔• M<strong>an</strong>ually resettable burner switches ................................... ✔ ✔ ✔ ✔ ✔ ✔• Masonry Chimney Venting w/BAYVENT800B ...................... ✔ ✔ ✔ ✔ ✔ —• Multi-port in shot burners .................................................... ✔ ✔ ✔ ✔ ✔ ✔• Painted cabinet single color ................................................ — — — — — ✔• Perfect fit door latches1 ..................................................... ✔ ✔ ✔ ✔ ✔ —• Right or left h<strong>an</strong>d side knock out for venting ......................... ✔ ✔ ✔ ✔ ✔ ✔(downflow models only)• Selectable cooling f<strong>an</strong> off delay eliminates need ................... ✔ ✔ ✔ ✔ ✔ ✔for time delay relay BAY24X045• Service diagnostic sight glass ............................................. ✔ ✔ ✔ ✔ ✔ —• Side return starter tabs ...................................................... TUD TUD TUD TUD TUD TUE• Silicon Carbide hot surface igniter with adaptive heat up ....... — — — — — ✔• Silicon Nitride hot surface igniter with adaptive heat up .......... ✔ ✔ ✔ ✔ ✔ —• Single door filter access ..................................................... ✔ ✔ ✔ ✔ ✔ —• Single wire twinning ........................................................... — ✔ ✔ ✔ ✔ —• Slide out blower assembly .................................................. ✔ ✔ ✔ ✔ ✔ ✔• St<strong>an</strong>dard filter sizes1 ........................................................ ✔ ✔ ✔ ✔ ✔ —PHASED OUT• 3-way vent option on downflow models (top,right or left) ........ ✔ ✔ ✔ ✔ ✔ ✔(downflow only) .................................................................• 20 gauge aluminized steel heat exch<strong>an</strong>ger .......................... ✔ ✔ ✔ ✔ ✔ ✔• 24 volt secondary fuse ....................................................... ✔ ✔ ✔ ✔ ✔ ✔• Two heating blower speeds ............................................... ✔ ✔ — — — —• Two speed venter motor .................................................... ✔ ✔ — — — —• Two tone color ................................................................... ✔ ✔ ✔ ✔ ✔ —• Two-stage gas valve .......................................................... ✔ ✔ — — — —• Non-prorated 20-year heat exch<strong>an</strong>ger limited warr<strong>an</strong>ty ......... ✔ ✔ ✔ ✔ ✔ ✔(<strong>Residential</strong> only)*• 5-year limited warr<strong>an</strong>ty on parts* ......................................... ✔ ✔ ✔ ✔ ✔ ✔1 Upflow only.NOTE: Variable speed XV80 furnaces should not be twinned <strong>an</strong>d are not approved for twinning applications.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.FUR-11 Effective 1/1/06


XV, XL, XT, XR, XB 80Convertible Gas FurnacesAirflow Directions:Downflow models when placed in horizontal position provide leftto right airflow. Upflow models when placed in horizontal positionprovide right to left airflow.XV 80 XL 80 XT 80 XR 80 XR 80 XB 80TUD-R-V-K TUD-R-K TUD1/TDD1 TUD1/TDD1 TUD-C-K TUE-TDETDD-R-V-F 2-Stg. TDD-R-F 1 Stage 1 Stage TDD-C-F 1 StageTable FUR-12-A — Optional Accessories Variable Speed 2 Stage High Efficiency 1 StageBAYBASE205 ........... Downflow subbase for ................................ ✔ ✔ ✔ ✔ ✔ ✔downflow models onlyBAYFLTR200 ............ Side Filter Rack (External) .......................... ✔ ✔ — TUD1 — —BAYFLTR203 ............ Filter kit horiz conversion ............................ ✔ ✔ — — ✔for 17.5" cabinetBAYFLTR204 ............ Filter kit horiz conversion ............................ ✔ ✔ — — ✔ ✔for 21" cabinetBAYFLTR205 ............ Filter kit horiz conversion ............................ ✔ ✔ — — ✔ ✔for 24.5" cabinetBAYFLTR206 ............ Filter Access Door Kit ................................ ✔ ✔ TDD1 TDD1 ✔ ✔BAYFLTR3171 ......... Cle<strong>an</strong>able filter for 14.5" ........................... — — ✔ ✔ — ✔<strong>an</strong>d 17.5" cabinet upflow onlyBAYFLTR3211 ......... Cle<strong>an</strong>able filter for .................................... ✔ ✔ ✔ ✔ ✔ ✔21" cabinet upflow onlyBAYFLTR3241 ......... Cle<strong>an</strong>able filter for .................................... ✔ ✔ ✔ ✔ ✔ ✔24.5" cabinet upflow onlyBAYLPKT210B ......... Prop<strong>an</strong>e conversion kit ............................... ✔ ✔ ✔ ✔ ✔ ✔BAYLPSS210B ......... LP Kit with Stainless .................................. ✔ ✔ ✔ ✔ ✔ ✔Steel BurnersBAYRACK960A235 . Filter Rack Kit for upflow ............................. TUD TUD ✔ ✔ TUD TUEmodels only (internal)PHASED OUTBAYVENT800B4 ...... Masonry chimney vent kit ........................... ✔ ✔ ✔ ✔ — —1 Contains one (1) high velocity filter.2 Available for models with 1800 CFM or greater witch require <strong>an</strong> additional side return.3 Upflow only.4 TUD-C-J/TUD-R-J <strong>an</strong>d later5 Includes 17" Cle<strong>an</strong>able Filter.NOTE: Variable Speed XV80 Furnaces should not be twinned <strong>an</strong>d are not approved for twinning applications.Special Use Furnace AccessoriesTable FUR-12-B — High Altitude Pressure Switch 80%ModelShippingNumber Description Used With WeightBAYHALT248 1 Switch TUD-C-K/TDD-C-F.TUE-A-L/TDE-A-M, 2TUD1, TDD1BAYHALT249 1 Switch TUD-R-K,TDD-R-F 2BonnetSwitchTAYPLUS103ATable FUR-12-C — Dual Fuel Heat Pump Control Kit12Model Number Case Height Used WithTAYPLUS103A ........... Heat Pump Control Kit ........... Gas, LP., Oil <strong>an</strong>d Electric FurnacesTAYSTAT250B ........... Outdoor Thermostat ............... TAYPLUS103A for Restricted ModeTHT1248 ..................... Bonnet Switch ........................ Oil Furnaces Only (Order Separately)1 Factory wired for non-restricted mode, c<strong>an</strong> be wired for restricted mode.2 Applicable for all furnaces with 35 VA or larger low voltage tr<strong>an</strong>sformer (separate high voltage power not required).Effective 1/1/06FUR-12For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


XV80 Variable SpeedHigh Efficiency Oil FurnacesTDF -Downflow/Horizontal• Up to 82.7% Annual Fuel Utilization Efficiency(AFUE)• 13 gauge hot rolled steel wrap around heatexch<strong>an</strong>ger for durability• Beckett Flame Retention Burner operatescle<strong>an</strong>ly <strong>an</strong>d quietly• Burner features include primary control withinterrupted ignition for reliability, pre-purge <strong>an</strong>dcle<strong>an</strong> cutoff solenoid valve for smooth ignition• Burner <strong>an</strong>d controls factory wired• Dual cle<strong>an</strong> out ports for quick access <strong>an</strong>d easycle<strong>an</strong>ing• Insulated blower compartment• Variable speed blower motorTLF -Lowboy FrontFlue (TLR not shown)• Slide out blower assembly for quickcle<strong>an</strong>ing <strong>an</strong>d service accessibility• Filter rack with cle<strong>an</strong>able filter (Highboy &Lowboy Models) except Downflow/Horizontal• 5 year limited parts warr<strong>an</strong>ty• Limited lifetime heat exch<strong>an</strong>ger warr<strong>an</strong>ty• Preformed ceramic fibercombustion chamber for higher efficiencies<strong>an</strong>d more complete combustion• 40 VA control tr<strong>an</strong>sformer for add oncooling• Heavy gauge, powder painted (two tone),steel cabinetTHV -Highboy Vertical• Recessed door h<strong>an</strong>dles for easy removal ofHighboy & lowboy Furnace doors• Lowboy models available with front or rearflue option• Highboy models with top or right sideventing• Downflow/Horizontal model fieldconvertible from Downflow to right or lefthorizontal• 6” Left <strong>an</strong>d Right side fresh air knockouts –Highboy <strong>an</strong>d Lowboy Models• Barometric draft regulator includedTable FUR-13-A — Specifications:Airflow Nominal UncratedModel In Tons Cap-BTUH ICS FLue Dimensions(In.) Mfg. ShippingNumber (Nom.) *Htg Output AFUE Size H W D Pl<strong>an</strong>t WeightTHV1M087A9V3SAA 3 87,000 82.4 6" 58 22.25 31 TR 260THV1M087A9V5SAA 5 87,000 82.6 6" 58 22.25 31 TR 260TLF1M087A9V3SAA 3 87,000 82.0 6" 41.5 22.25 47 TR 300TLF1M087A9V5SAA 5 87,000 82.7 6" 41.5 22.25 47 TR 300TLR1M087A9V3SAA 3 87,000 82.0 6" 41.5 22.25 47 TR 300TLR1M087A9V5SAA 5 87,000 82.4 6" 41.5 22.25 47 TR 300TDF1M087A9V5SAA 3 87,000 81.7 6" 22.25 61.25 22.25 TR 280TDF1M087A9V5SAA 5 87,000 82.6 6" 22.25 61.25 22.25 TR 280* Other input/output capacities are available by ch<strong>an</strong>ging the burner nozzle. See installer's guide for details.Table FUR-13-B — Accessories:Mfg. ShippingModel Description Used With Pl<strong>an</strong>t WeightBAYSUB10ABASEAA Downflow Subbase TDF1M087A9V3, 9V5SAA TR 22BAYTRM10AVENTAA Top P<strong>an</strong>el & Trim Ring THV1M087A9V3, 9V5SAA TR 1For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.FUR-13 Effective 1/1/06


XP80 High Efficiency Oil FurnacesTDF -Downflow/Horizontal• Up to 82.4% Annual Fuel UtilizationEfficiency (AFUE)• 13 gauge hot rolled steel wrap around heatexch<strong>an</strong>ger for durability• Beckett Flame Retention Burner operatescle<strong>an</strong>ly <strong>an</strong>d quietly• Burner features include primary control withinterrupted ignition for reliability, pre-purge<strong>an</strong>d cle<strong>an</strong> cutoff solenoid valve for smoothignition• Burner <strong>an</strong>d controls factory wired• Dual cle<strong>an</strong> out ports for quick access <strong>an</strong>deasy cle<strong>an</strong>ing• Direct drive, perm<strong>an</strong>ently lubricated, 4speed blower motorTLF -Lowboy FrontFlue (TLR not shown)• Insulated blower compartment• Slide out blower assembly for quick cle<strong>an</strong>ing<strong>an</strong>d service accessibility• Filter rack with washable filter (Highboy &Lowboy Models) except Downflow/Horizontal• 5 year parts limited warr<strong>an</strong>ty <strong>an</strong>d lifetime heatexch<strong>an</strong>ger warr<strong>an</strong>ty• Preformed ceramic fibercombustion chamber for higher efficiencies<strong>an</strong>d more complete combustion• 40 VA control tr<strong>an</strong>sformer for add on cooling• Heavy gauge, powder painted (two tone),steel cabinetTHV -Highboy Vertical• Recessed door h<strong>an</strong>dles for easy removal ofHighboy & lowboy Furnace doors• Lowboy models available with front or rearflue option• Highboy models with top or right sideventing• Downflow/Horizontal model fieldconvertible from Downflow to right or lefthorizontal• 6” Left <strong>an</strong>d Right side fresh air knockouts –Highboy <strong>an</strong>d Lowboy Models• Barometric draft regulator includedTable FUR-14-A — Specifications:Airflow Nominal UncratedModel In Tons Cap-BTUH ICS FLue Dimensions(In.) Mfg. ShippingNumber (Nom.) *Htg Output AFUE Size H W D Pl<strong>an</strong>t WeightTHV1M087A936SAA 3 87,000 82.4 6" 58 22.25 31 TR 260THV1M087A948SAA 4 87,000 82.4 6" 58 22.25 31 TR 260TLF1M087A936SAA 3 87,000 82.0 6" 41.5 22.25 47 TR 300TLF1M087A948SAA 4 87,000 82.0 6" 41.5 22.25 47 TR 300TLR1M087A936SAA 3 87,000 82.0 6" 41.5 22.25 47 TR 300TLR1M087A948SAA 4 87,000 82.0 6" 41.5 22.25 47 TR 300TDF1M087A936SAA 3 87,000 81.7 6" 22.25 61.25 22.25 TR 280TDF1M087A948SAA 4 87,000 81.7 6" 22.25 61.25 22.25 TR 280* Other input/output capacities are available by ch<strong>an</strong>ging the burner nozzle. See installer's guide for details.Table FUR-14-B — Accessories:Mfg. ShippingModel Description Used With Pl<strong>an</strong>t WeightBAYSUB10ABASEAA Downflow Subbase TDF1M087A936, 948SAA TR 22BAYTRM10AVENTAA Top P<strong>an</strong>el & Trim Ring THV1M087A936, 948SAA TR 1Effective 1/1/06FUR-14For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Upflow/Horizontal90% Gas Furnace Quick ReferenceSpecifications:Furnace Nom. Blower Flue Prop<strong>an</strong>e Outlet Return AirModel BTUH ICS1 Max.2 Speed Motor Size Conversion Air Bottom SideNumber2 Output AFUE Airflow Taps H.P. (in.) Kit W D W D H DUPFLOW/HORIZONTAL — XV 90 VARIABLE SPEED WITH RECUPERATIVE CELL DIRECT/NON DIRECT VENT TWO-STAGETUY060R9V3W 56,000 93.0 1275 Var. Var. 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUY080R9V3W 73,000 92.5 1400 Var. Var. 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUY100R9V4W 93,000 93.0 1770 Var. Var. 2 1 /2–3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75TUY120R9V5W 112,000 92.5 1920 Var. Var. 3 Only BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/HORIZONTAL — XL 90 DIRECT/NON-DIRECT VENT, TWO STAGE, 1 OR 2 PIPE, UPFLOW/HORIZONTAL CONDENSING GAS FURNACETUX060R936W 56,000 93.0 1196 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX080R942W 73,000 92.5 1470 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX100R948W 93,000 93.0 1746 4 1/2 2 1 /2–3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75TUX120R960W 112,000 92.5 2261 4 3/4 3 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/ HORIZONTAL- XT 90 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE (115/1/60)TUX1B040A9H21A 38,000 92.1 1052 4 1/2 2, 2 1 /2, 3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX1B060A9H31A 56,000 92.1 1248 4 1/2 2, 2 1 /2, 3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX1B080A9H31A 74,000 92.1 1320 4 1/2 2, 2 1 /2, 3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX1C100A9H41A 94,000 92.1 1737 4 3/4 2 1 /2, 3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75TUX1D120A9H51A 113,000 92.1 2023 4 1.0 2 1 /2, 3 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/ HORIZONTAL- XR 90 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE (115/1/60)TUX1B040A9241A 38,000 92.1 812 4 1/5 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX1B060A9361A 56,000 92.1 1196 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX1B080A9421A 74,000 92.1 1470 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX1B080A9601A 76,000 92.1 2121 4 1/2 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX1C100A9481A 94,000 92.1 1746 4 1/2 2 1 /2–3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75TUX1C100A9601A 93,000 92.1 2165 4 1/2 2 1 /2–3 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUX1D120A9601A 113,000 92.1 2261 4 1/2 3 Only BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/HORIZONTAL — XB 90 WITH RECUPERATIVE COIL SINGLE STAGETUC040C924B 37,000 92.1 812 4 1/5 2 1 /2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUC060C936B 56,000 92.1 1196 4 1/3 2 1 /2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUC080C942B 74,000 92.1 1470 4 1/3 2 1 /2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUC100C948B 94,000 92.1 1746 4 1/2 2 1 /2–3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75TUC100C960B 93,000 92.1 2165 4 1/2 2 1 /2–3 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUC120C960B 113,000 92.1 2261 4 1/2 3 Only BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/HORIZONTAL — XR 90 WITH RECUPERATIVE COIL DIRECT/NON DIRECT VENT SINGLE STAGETUX040C924D 38,000 92.1 812 4 1/5 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX060C936D 56,000 92.1PHASED1196 4 1/3 2–3 BAYLPKT210BOUT16.25 19.6 16 23.5 14.88 23.75TUX080C942D 74,000 92.1 1470 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX080C960D 76,000 92.1 2121 4 1/2 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX100C948D 94,000 92.1 1746 4 1/2 2 1 /2–3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75TUX100C960D 93,000 92.1 2165 4 1/2 2 1 /2–3 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUX120C960D 113,000 92.1 2261 4 1/2 3 Only BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.751 Isolated Combustion System.2 CFM @ .5 inches ESP with filter in place.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.FUR-15 Effective 1/1/06


Downflow/Horizontal90% Gas Furnace Quick ReferenceSpecifications:Furnace Nom. Blower Flue Prop<strong>an</strong>e Outlet ReturnModel BTUH ICS1 Max.2 Speed Motor Size Conversion Downflow Air AirNumber Output AFUE Airflow Taps H.P. (in.) Kit Subbase W D H DDOWNFLOW/HORIZONTAL — XV 90 VARIABLE SPEED WITH RECUPERATIVE CELL DIRECT VENT TWO-STAGETDY060R9V3W 56,000 92.0 1350 Var. Var. 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDY080R9V3W 74,000 92.5 1210 Var. Var. 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDY100R9V4W 94,000 93.0 1800 Var. Var. 2 1 /2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDY120R9V5W 112,000 92.5 1900 Var. Var. 3 Only BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6DOWNFLOW/HORIZONTAL— XL 90 NON-DIRECT VENT, TWO STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACETDX060R936W 55,000 92.0 1209 4 1/3 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX080R942W 74,000 92.5 1323 4 1/2 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX100R948W 93,000 93.0 1614 4 1/2 2 1 /2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDX120R960W 111,000 92.5 1939 4 3/4 3 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6DOWNFLOW/ HORIZONTAL- XT 90 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACETDX1B040A9H31A 38,000 91.0 1043 4 1/2 2, 2 1 /2, 3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX1B060A9H31A 56,000 91.0 1223 4 1/2 2, 2 1 /2, 3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX1B080A9H31A 74,000 91.0 1423 4 3/4 2, 2 1 /2, 3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX1C100A9H41A 94,000 91.0 1700 4 3/4 2 1 /2, 3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDX1D120A9H51A 112,000 91.0 2006 4 1.0 2 1 /2, 3 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6DOWNFLOW/ HORIZONTAL- XR 90 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACETDX1B040A9241A 38,000 91.0 807 4 1/5 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX1B060A9361A 56,000 91.0 1209 4 1/3 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX1B080A9421A 74,000 91.0 1323 3 1/2 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX1C100A9481A 94,000 91.0 1614 3 1/2 2 1 /2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDX1D120A9601A 112,000 91.0 1939 3 1/2 3 Only BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6DOWNFLOW/HORIZONTAL — XB 90 WITH RECUPERATIVE COIL SINGLE STAGETDC040C924B 38,000 91.0 807 4 1/5 2 1 /2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDC060C936B 56,000 91.0 1082 4 1/3 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDC080C942B 74,000 91.0 1323 3 1/2 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDC100C948B 93,000 91.0 1614 3 1/2 2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDC120C960B 112,000 91.0 1939 3 1/2 3 Only BAYLPKT210B BAYBASE205 23.0 19.6 23.25 19.6DOWNFLOW/HORIZONTAL — XR 90 WITH RECUPERATIVE COIL DIRECT VENT SINGLE STAGETDX040C924D 38,000 91.0PHASED807 4 1/5 2–3 BAYLPKT210BOUTBAYBASE205 16 19.6 16.25 19.6TDX060C936D 56,000 91.0 1209 4 1/3 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX080C942D 74,000 91.0 1323 3 1/2 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX100C948D 94,000 91.0 1614 3 1/2 2 1 /2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDX120C960D 112,000 91.0 1939 3 1/2 3 Only BAYLPKT210B BAYBASE205 23 19.6 23.25 19.61 Isolated Combustion System.2 CFM @ .5 inches ESP with filter in place.Effective 1/1/06FUR-16For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Upflow/Horizontal80% Gas Furnace Quick ReferenceSpecifications:Furnace Nom. Blower Flue Prop<strong>an</strong>e Outlet Return AirModel BTUH ICS1 Max.2 Speed Motor Size Conversion Air Bottom SideNumber2 Output AFUE Airflow Taps H.P. (in.) Kit W D W D H DUPFLOW/HORIZONTAL — XV 80 VARIABLE SPEED TWO-STAGETUD060R9V3K 48,000 80.0 1402 Var. Var. 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD080R9V3K 64,000 80.0 1410 Var. Var. 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD080R9V4K 64,000 80.0 1591 Var. Var. 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD100R9V3K 80,000 80.0 1251 Var. Var. 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD100R9V5K 79,000 80.0 2100 Var. Var. 4 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75TUD120R9V5K 97,000 80.0 2019 Var. Var. 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD140R9V5K 112,000 80.0 2075 Var. Var. 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/HORIZONTAL — XL 80 INDUCED DRAFT TWO-STAGETUD040R924K 32,000 80.0 910 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD060R936K 47,000 80.0 1236 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD060R937K 47,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD080R936K 63,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD080R948K 63,000 80.0 1710 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD100R936K 79,000 80.0 1363 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD100R948K 79,000 80.0 1669 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD100R960K 80,000 80.0 1978 4 1/2 4 BAYLPKT210B 19.75 19.6 23 23.5 14.88 23.75TUD100R961K 80,000 80.0 2175 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD120R954K 95,000 80.0 2037 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD120R960K 95,000 80.0 2005 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD140R960K 112,000 80.0 2216 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/ HORIZONTAL- XT 80 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACETUD1A040A9H21A 32,000 80.0 1011 4 1/2 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD1B060A9H31A 47,000 80.0 1238 4 1/2 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1B080A9H31A 63,000 80.0 1318 4 1/2 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1C080A9H41A 64,000 80.0 1600 4 3/4 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD1B100A9H31A 79,000 80.0 1280 4 3/4 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1C100A9H51A 79,000 80.0 2038 4 1.0 4 BAYLPKT210B 19.25 19.6 19.5 23.5 14.88 23.75TUD1D120A9H51A 96,000 80.0 1996 4 1.0 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD1D140A9H51A 111,000 80.0 1984 4 1.0 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/ HORIZONTAL- XR 80 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACETUD1A040A9241A 32,000 80.0 910 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD1A040A9301A 32,000 80.0 1092 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD1A060A9241A 47,000 80.0 901 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD1A060A9361A 47,000 80.0 1236 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD1B060A9361A 47,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1B080A9241A 64,000 80.0 956 4 1/5 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1B080A9361A 63,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1B080A9481A 64,000 80.0 1710 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1C080A9601A 64,000 80.0 2163 4 3/4 4 BAYLPKT210B 16.25 19.6 19.5 23.5 14.88 23.75TUD1B100A9361A 79,000 80.0 1363 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1B100A9451A 80,000 80.0 1556 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.55TUD1C100A9481A 79,000 80.0 1669 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD1C100A9601A 79,000 80.0 2001 4 1/2 4 BAYLPKT210B 19.75 19.6 23 23.5 14.88 23.75TUD1D100A9721A 80,000 80.0 2249 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD1C120A9541A 96,000 80.0 2037 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD1D120A9601A 96,000 80.0 2005 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD1D140A9601A 111,000 80.0 2216 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/HORIZONTAL— XB 80 INDUCED DRAFT SINGLE STAGETUE040A924L 31,000 80.0 910 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUE060A936L 47,000 80.0 1296 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUE060A937L 47,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUE080A936L 63,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUE080A948L 64,000 80.0 1710 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUE100A936L 79,000 80.0 1363 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUE100A948L 79,000 80.0 1669 4 1/2 4 BAYLPKT210B 19.25 19.6 19.5 23.5 14.88 23.75TUE100A960L 79,000 80.0 2001 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUE120A960L 96,000 80.0 2005 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUE140A960L 111,000 80.0 2216 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/HORIZONTAL — XR 80 INDUCED DRAFT SINGLE STAGETUD040C924K 32,000 80.0 910 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD040C930K 32,000 80.0 1092 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD060C924K 47,000 80.0 901 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD060C936K 47,000 80.0 1236 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD060C937K 47,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD080C924K 64,000 80.0 956 4 1/5 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD080C936K 63,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD080C948K 64,000 80.0 1710 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD080C960K 64,000 80.0 2163 4 3/4 4 BAYLPKT210B 16.25 19.6 19.5 23.5 14.88 23.75TUD100C936K 79,000 80.0 1363 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75PHASED OUTTUD100C945K 80,000 80.0 1556 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.55TUD100C948K 79,000 80.0 1669 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD100C960K 79,000 80.0 2001 4 1/2 4 BAYLPKT210B 19.75 19.6 23 23.5 14.88 23.75TUD100C972K 80,000 80.0 2249 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD120C954K 96,000 80.0 2037 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD120C960K 96,000 80.0 2005 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD140C960K 111,000 80.0 2216 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.751 Isolated Combustion System. 2 CFM @ .5 inches ESP with filter in place.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.FUR-17 Effective 1/1/06


Downflow/Horizontal80% Gas Furnace Quick ReferenceSpecifications:Furnace Nom. Blower Flue Prop<strong>an</strong>e Outlet ReturnModel BTUH ICS1 Max.2 Speed Motor Size Conversion Downflow Air AirNumber Output AFUE Airflow Taps H.P. (in.) Kit Subbase W D H DDOWNFLOW/HORIZONTAL — XV 80 VARIABLE SPEED TWO STAGETDD060R9V3F 48,000 80.0 1360 Var. Var. 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD080R9V3F 63,000 80.0 1315 Var. Var. 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD100R9V5F 81,000 80.0 2015 Var. Var. 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD120R9V5F 95,000 80.0 2215 Var. Var. 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6DOWNFLOW/HORIZONTAL — XL 80 TWO-STAGE INDUCED DRAFTTDD040R924F 32,000 80.0 960 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6TDD060R936F 47,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6TDD060R937F 47,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD080R936F 64,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD100R945F 79,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD100R948F 79,000 80.0 1740 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD100R960F 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD120R960F 94,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6TDD140R960F 113,000 80.0 2133 4 3/4 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6DOWNFLOW/ HORIZONTAL- XT 80 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACETDD1B060A9H31A 48,000 80.0 1309 4 1/2 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD1B080A9H31A 64,000 80.0 1314 4 1/2 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD1C100A9H51A 81,000 80.0 2007 4 1.0 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD1D120A9H51A 96,000 80.0 2010 4 1.0 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6DOWNFLOW/ HORIZONTAL- XR 80 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACETDD1A040A9241A 31,000 78.0 920 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6TDD1A060A9241A 48,000 80.0 1001 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6TDD1A060A9361A 48,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6TDD1B060A9361A 48,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD1B080A9361A 64,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD1B080A9451A 64,000 80.0 1575 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD1B100A9451A 80,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD1C100A9481A 80,000 80.0 1740 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD1C100A9541A 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD1C120A9541A 96,000 80.0 1918 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD1D120A9601A 96,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6TDD1D140A9601A 113,000 80.0 2133 4 3/4 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6DOWNFLOW/HORIZONTAL — XB 80 INDUCED DRAFT SINGLE STAGETDE060A936M 48,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6TDE060A937M 48,000 80.0 1281 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDE080A945M 64,000 80.0 1575 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDE100A945M 80,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDE100A960M 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDE120A960M 96,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6DOWNFLOW/HORIZONTAL — XR 80 INDUCED DRAFT SINGLE STAGETDD040C924F 31,000 78.0 920 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6TDD060C924F 48,000 80.0 1001 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6TDD060C936F 48,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6TDD060C937F 48,000PHASED80.0 1369 4 1/3 4 BAYLPKT210BOUTBAYBASE205 16 19.6 16.25 19.6TDD080C936F 64,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD080C945F 64,000 80.0 1575 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD100C945F 80,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD100C948F 80,000 80.0 1740 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD100C954F 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD120C954F 96,000 80.0 1918 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD120C960F 96,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6TDD140C960F 113,000 80.0 2133 4 3/4 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.61 Isolated Combustion System.2 CFM @ .5 inches ESP with filter in place.Effective 1/1/06FUR-18For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


High EfficiencySplit System – CasedHeat Pump <strong>an</strong>d Cooling CoilsComfort TM coilLEFTUPDOWN3 WAYCOIL2/4TXC ComfortCoil Features:• All Aluminium coil to reduceformicary corrosion• All Non-Bleed TXV valveswith internal check valve forheat pump operation• Split inner <strong>an</strong>d outer doorsfor easy coil cle<strong>an</strong>ing• Double sloped non corrosivedrain p<strong>an</strong>s- UL Rated 400°F• Suction pressure serviceport• 100% foil faced insulation• Easy case attachment tofurnace• 3 way application• Painted cabinet matchesfurnace• 10 Year limited partswarr<strong>an</strong>ty on all AluminiumcoilsTXF Features:• Bi-directional airflow• Sloped non corrosive drain p<strong>an</strong>• HP TXV with mech<strong>an</strong>icalfittings• Galv<strong>an</strong>ized steel cabinet• 100% foil lined insulationFURNACEAIRFLOWFURNACEAIRFLOWReversible Features:• Bi-Directional Airflow• Same side service access forHorizontal Right or Leftapplications• Eliminates need for fieldinstalled Horizontal DripTray!!!• Fully Convertible - Upflow,Downflow, Left or Right• Heat Pump <strong>an</strong>d CoolingCompatible• Suction service port• 100% foil lined insulation• Split inner <strong>an</strong>d outer doors foreasy coil cle<strong>an</strong>ing• Double sloped non-corrosivedrain p<strong>an</strong> - UL rated 400°F• 5 year limited parts warr<strong>an</strong>tyon all coils• Non-Bleed TXV withmech<strong>an</strong>ical fittingsFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.Table FUR-19-A — Aluminum High Efficiency Coils (Upflow/Downflow/Horizontal Left) R-22 Refriger<strong>an</strong>tNom. Cap. Outlet Overall Shipping Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.2TXCB025AS3HCA 30,000 A TXV-NB1 15 5 /8 x 19 3 /8 17.5 x 17.5 x 21.5 42 5/8 3/82TXCB031AS3HCA 30,000 A TXV-NB1 15 5 /8 x 19 3 /8 22.5 x 17.5 x 21.5 54 7/8 3/82TXCB036AS3HCA 36,000 A TXV-NB1 15 5 /8 x 19 3 /8 26.88 x 17.5 x 21.5 67 7/8 3/82TXCC037AS3HCA 36,000 A TXV-NB1 19 1 /8 x 19 3 /8 26.88 x 21 x 21.5 70 7/8 3/82TXCC054AS3HCA 54,000 A TXV-NB1 19 1 /8 x 19 3 /8 30 x 21 x 21.5 73 1 1 /8 3/82TXCD065AS3HCA 60,000 A TXV-NB1 22 5 /8 x 19 3 /8 33* x 24.5 x 21.5 90 1 1 /8 3/8Table FUR-19-B — Aluminum High Efficiency Coils (Upflow/Downflow/Horizontal Left) R-410A Refriger<strong>an</strong>tNom. Cap. Outlet Overall Shipping Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.4TXCB025AS3HCA 30,000 A TXV-NB1 15 5 /8 x 19 3 /8 17.5 x 17.5 x 21.5 42 5/8 3/84TXCB031AS3HCA 30,000 A TXV-NB1 15 5 /8 x 19 3 /8 22.5 x 17.5 x 21.5 54 7/8 3/84TXCB036AS3HCA 36,000 A TXV-NB1 15 5 /8 x 19 3 /8 26.88 x 17.5 x 21.5 67 7/82 3/84TXCC037AS3HCA 36,000 A TXV-NB1 19 1 /8 x 19 3 /8 26.88 x 21 x 21.5 70 7/8 3/84TXCC054AS3HCA 54,000 A TXV-NB1 19 1 /8 x 19 3 /8 30 x 21 x 21.5 73 1 1 /83 3/84TXCD065AS3HCA 60,000 A TXV-NB1 22 5 /8 x 19 3 /8 33* x 24.5 x 21.5 90 1 1 /83 3/8Table FUR-19-C —Cased Horizontal Flat Coil R-22 Refriger<strong>an</strong>tNom. Cap. Outlet Overall Shipping Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.2TXFH018AS3HHA 18,000 Flat TXVNB1 24 x 21 22 x 10 x 28 40 5/8 1/42TXFH033AS3HHA 34,000 Flat TXVNB1 24 x 21 22 x 10 x 28 46 3/4 5/162TXFH041AS3HHA 44,000 Flat TXVNB1 33 1 /4 x 21 22 x 10 x 37 56 7/8 3/82TXFH054AS3HHA 58,000 Flat TXVNB1 33 1 /4 x 21 22 x 10 x 37 64 1 1 /82TXFH063AS3HHA 61,000 Flat TXVNB1 33 1 /4 x 27 28 x 10 x 37 79 1 1 /8Table FUR-19-D —Cased Horizontal Flat Coil R-410A Refriger<strong>an</strong>tNom. Cap. Outlet Overall Shipping Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.4TXFH018AS3HHA 18,000 Flat TXVNB1 24 x 21 22 x 10 x 28 40 1/24TXFH033AS3HHA 34,000 Flat TXVNB1 24 x 21 22 x 10 x 28 46 3/44TXFH041AS3HHA 44,000 Flat TXVNB1 33 1 /4 x 21 22 x 10 x 37 56 3/44TXFH054AS3HHA 58,000 Flat TXVNB1 33 1 /4 x 21 22 x 10 x 37 64 7/84TXFH063AS3HHA 61,000 Flat TXVNB1 33 1 /4 x 27 28 x 10 x 37 79 7/8Table FUR-19-E — Reversible, Cased Heat Pump/Cooling Coils — (Upflow/Downflow Horizontal Leftor Right) R-22 Refriger<strong>an</strong>tNom. Cap. Maximum Outlet Overall Shipping Line SizeModel Cooling Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) (CFM**) Type Control W/H x D H x W x D (Ibs.) Gas Liq.2TXCA024AC3HMA 24,000 1000 A TXVNB1 12 5 /8 x 19 3 /8 30 x 14.5 x 21.5 1000 3/4 5/162TXCB036AC3HMA 36,000 1200 A TXVNB1 15 5 /8 x 19 3 /8 30 x 17.5 x 21.5 1200 7/8 3/81 Start Kits may be required on outdoor unit.2 7 /8 x 3 /4 reducing coupling shipped with R-410A model coil.3 1 1 /8 x 7 /8 reducing coupling shipped with R-410A model coil.*Overall height. Actual height of case is 30".**Water Blowoff may occur if Maximum Cooling airflow is exceeded.FUR-19 Effective 1/1/063/83/81/45/163/83/83/8


Split System – CasedHeat Pump <strong>an</strong>d Cooling CoilsTable FUR-20-A — Cased Coil Convertible (Upflow/ Downflow/ Horizontal Left) R-22 Refriger<strong>an</strong>tNom. Cap. Outlet Overall Shipping Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.Comfort TM coilTXC ComfortCoil Features:• HP TXV Mech<strong>an</strong>icalFittings (2/4 TXC)• Split inner <strong>an</strong>d outer doorsfor easy coil cle<strong>an</strong>ing• Double sloped noncorrosive drain p<strong>an</strong>s-UL Rated 400°F• Suction pressure serviceport• 100% foil lined insulation• Easy case attachment tofurnace• 3 way application• Painted cabinet matchesfurnace• 5 year limited partswarr<strong>an</strong>ty• Copper tube Aluminum fin2TXCA018AC3HCA 18,000 A TXVNB1 12 5 /8 x 19 3 /8 17.6 x 14.5 x 21.5 34 5/82TXCA024AC3HCA 24,000 A TXVNB1 12 5 /8 x 19 3 /8 22.6 x 14.5 x 21.5 37 3/42TXCB025AC3HCA 24,000 A TXVNB1 15 5 /8 x 19 3 /8 17.6 x 17.5 x 21.5 42 3/42TXCB031AC3HCA 30,000 A TXVNB1 15 5 /8 x 19 3 /8 17.6 x 17.5 x 21.5 46 3/42TXCB036AC3HCA 36,000 A TXVNB1 15 5 /8 x 19 3 /8 22.6 x 17.5 x 21.5 54 7/82TXCC037AC3HCA 37,000 A TXVNB1 19 1 /8 x 19 3 /8 22.6 x 21 x 21.5 53 7/82TXCB042AC3HCA 42,000 A TXVNB1 15 5 /8 x 19 3 /8 22.6 x 17.5 x 21.5 59 7/82TXCC043AC3HCA 43,000 A TXVNB1 19 1 /8 x 19 3 /8 22.6 x 21 x 21.5 56 1 1 /82TXCB048AC3HCA 48,000 A TXVNB1 15 5 /8 x 19 3 /8 26.9 x 17.5 x 21.5 71 1 1 /82TXCC049AC3HCA 48,000 A TXVNB1 19 1 /8 x 19 3 /8 26.9 x 21 x 21.5 67 1 1 /82TXCD050AC3HCA 48,000 A TXVNB1 22 5 /8 x 19 3 /8 26.9 x 24.5 x 21.5 77 1 1 /82TXCC060AC3HCA 60,000 A TXVNB1 19 1 /8 x 19 3 /8 30.1 x 21 x 21.5 74 1 1 /82TXCD061AC3HCA 60,000 A TXVNB1 22 5 /8 x 19 3 /8 30.1 x 24.5 x 21.5 77 1 1 /8Table FUR-20-B — Cased Coil Convertible (Upflow/ Downflow/ Horizontal Left) R-410A Refriger<strong>an</strong>tNom. Cap. Outlet Overall Shipping Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.4TXCA018AC3HCA 18,000 A TXVNB1 12 5 /8 x 19 3 /8 17.6 x 14.5 x 21.5 34 5/8 1/44TXCA024AC3HCA 24,000 A TXVNB1 12 5 /8 x 19 3 /8 22.6 x 14.5 x 21.5 37 3/4 5/164TXCB025AC3HCA 24,000 A TXVNB1 15 5 /8 x 19 3 /8 17.6 x 17.5 x 21.5 42 3/4 5/164TXCB031AC3HCA 30,000 A TXVNB1 15 5 /8 x 19 3 /8 17.6 x 17.5 x 21.5 46 3/4 5/164TXCB036AC3HCA 36,000 A TXVNB1 15 5 /8 x 19 3 /8 22.6 x 17.5 x 21.5 54 7/8 3/84TXCC037AC3HCA 37,000 A TXVNB1 19 1 /8 x 19 3 /8 22.6 x 21 x 21.5 53 7/8 3/84TXCB042AC3HCA 42,000 A TXVNB1 15 5 /8 x 19 3 /8 22.6 x 17.5 x 21.5 59 7/8 3/84TXCC043AC3HCA 43,000 A TXVNB1 19 1 /8 x 19 3 /8 22.6 x 21 x 21.5 56 1 1 /8 3/84TXCB048AC3HCA 48,000 A TXVNB1 15 5 /8 x 19 3 /8 26.9 x 17.5 x 21.5 71 1 1 /8 3/84TXCC049AC3HCA 48,000 A TXVNB1 19 1 /8 x 19 3 /8 26.9 x 21 x 21.5 67 1 1 /8 3/84TXCD050AC3HCA 48,000 A TXVNB1 22 5 /8 x 19 3 /8 26.9 x 24.5 x 21.5 77 1 1 /8 3/84TXCC060AC3HCA 60,000 A TXVNB1 19 1 /8 x 19 3 /8 30.1 x 21 x 21.5 74 1 1 /8 3/84TXCD061AC3HCA 60,000 A TXVNB1 22 5 /8 x 19 3 /8 30.1 x 24.5 x 21.5 77 1 1 /8 3/81/45/165/165/163/83/83/83/83/83/83/83/83/8Comfort TM coilSplit System – CasedCooling Only Coils2/4CXC Coil Features:• Cased <strong>an</strong>d uncasedupflow /downflow coolingonly coils• Brazed fittings (left side)• Drain fitting (left side)• Non-Bleed TXV withmech<strong>an</strong>ical fittings.• Copper tube withAluminum fins• Painted coil case• Suction pressure serviceport• 100% foil lined insulation• Split inner <strong>an</strong>d outer doorsfor easy coil cle<strong>an</strong>ing• 5 Year limited partswarr<strong>an</strong>tyEffective 1/1/06Table FUR-20-C — Cooling Only Cased (Upflow/ Downflow) R-22 Refriger<strong>an</strong>tNom. Cap. Outlet Overall Shipping Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.2CXCA018AC3CUA 18,000 A TXVNB1 12 5 /8 x 19 3 /8 17.6 x 14.5 x 21.5 32 5/82CXCA024AC3CUA 24,000 A TXVNB1 12 5 /8 x 19 3 /8 22.6 x 14.5 x 21.5 34 3/42CXCB025AC3CUA 24,000 A TXVNB1 15 5 /8 x 19 3 /8 17.6 x 17.5 x 21.5 42 3/42CXCB031AC3CUA 30,000 A TXVNB1 15 5 /8 x 19 3 /8 17.6 x 17.5 x 21.5 44 3/42CXCB036AC3CUA 36,000 A TXVNB1 15 5 /8 x 19 3 /8 22.6 x 17.5 x 21.5 44 7/82CXCC037AC3CUA 37,000 A TXVNB1 19 1 /8 x 19 3 /8 22.6 x 21 x 21.5 53 7/82CXCB042AC3CUA 42,000 A TXVNB1 15 5 /8 x 19 3 /8 22.6 x 17.5 x 21.5 52 7/82CXCC043AC3CUA 43,000 A TXVNB1 19 1 /8 x 19 3 /8 22.6 x 21 x 21.5 56 1 1 /82CXCB048AC3CUA 48,000 A TXVNB1 15 5 /8 x 19 3 /8 26.9 x 17.5 x 21.5 58 1 1 /82CXCC049AC3CUA 48,000 A TXVNB1 19 1 /8 x 19 3 /8 26.9 x 21 x 21.5 67 1 1 /82CXCD050AC3CUA 48,000 A TXVNB1 22 5 /8 x 19 3 /8 26.9 x 24.5 x 21.5 77 1 1 /82CXCC060AC3CUA 60,000 A TXVNB1 19 1 /8 x 19 3 /8 30.1 x 21 x 21.5 70 1 1 /82CXCD061AC3CUA 60,000 A TXVNB1 22 5 /8 x 19 3 /8 30.1 x 24.5 x 21.5 72 1 1 /81 Start Kits may be required on outdoor unit.FUR-20For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.1/45/165/165/163/83/83/83/83/83/83/83/83/8


Split System - Cased/UncasedCooling Only CoilsTable FUR-21-A — Cooling Only Cased (Upflow/ Downflow) R-410A Refriger<strong>an</strong>tNom. Cap. Outlet Overall Shipping Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.Comfort TM coil2/4CXC Coil Features:• Cased <strong>an</strong>d uncasedupflow /downflow coolingonly coils• Brazed fittings (left side)• Drain fitting (left side)• Non-Bleed TXV withmech<strong>an</strong>ical fittings.• Copper tube withAluminum fins• Painted coil case• Suction pressure serviceport• 100% foil lined insulation• Split inner <strong>an</strong>d outer doorsfor easy coil cle<strong>an</strong>ing• 5 Year limited partswarr<strong>an</strong>ty4CXCA018AC3CUA 18,000 A TXVNB1 12 5 /8 x 19 3 /8 17.6 x 14.5 x 21.5 32 5/84CXCA024AC3CUA 24,000 A TXVNB1 12 5 /8 x 19 3 /8 22.6 x 14.5 x 21.5 34 3/44CXCB025AC3CUA 24,000 A TXVNB1 15 5 /8 x 19 3 /8 17.6 x 17.5x 21.5 42 3/44CXCB031AC3CUA 30,000 A TXVNB1 15 5 /8 x 19 3 /8 17.6 x 17.5 x 21.5 44 3/44CXCB036AC3CUA 36,000 A TXVNB1 15 5 /8 x 19 3 /8 22.6 x 17.5 x 21.5 44 7/84CXCC037AC3CUA 37,000 A TXVNB1 19 1 /8 x 19 3 /8 22.6 x 21 x 21.5 53 7/84CXCB042AC3CUA 42,000 A TXVNB1 15 5 /8 x 19 3 /8 22.6 x 17.5 x 21.5 52 7/84CXCC043AC3CUA 43,000 A TXVNB1 19 1 /8 x 19 3 /8 22.6 x 21 x 21.5 56 1 1 /84CXCB048AC3CUA 48,000 A TXVNB1 15 5 /8 x 19 3 /8 26.9 x 17.5 x 21.5 58 1 1 /84CXCC049AC3CUA 48,000 A TXVNB1 19 1 /8 x 19 3 /8 26.9 x 21 x 21.5 67 1 1 /84CXCD050AC3CUA 48,000 A TXVNB1 22 5 /8 x 19 3 /8 26.9 x 24.5 x 21.5 77 1 1 /84CXCC060AC3CUA 60,000 A TXVNB1 19 1 /8 x 19 3 /8 30.1 x 21 x 21.5 70 1 1 /84CXCD061AC3CUA 60,000 A TXVNB1 22 5 /8 x 19 3 /8 30.1 x 24.5 x 21.5 72 1 1 /8Table FUR-21-B — Cooling Only Uncased Coils (Upflow/ Downflow) R-22 Refriger<strong>an</strong>tNom. Cap. Overall Shipping Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Weight OD ODNumber (Btuh) Type Control H x W x D (Ibs.) Gas Liq.2CXAA018AC3CUA 18,000 A TXVNB1 15.9 x 13.3 x 21.1 17 5/8 1/42CXAA024AC3CUA 24,000 A TXVNB1 17.6 x 13.3 x 21.1 20 3/4 5/162CXAB025AC3CUA 24,000 A TXVNB1 15.9 x 16.3 x 21.1 21 3/4 5/162CXAB031AC3CUA 30,000 A TXVNB1 15.9 x 16.3 x 21.1 26 3/4 5/162CXAB036AC3CUA 36,000 A TXVNB1 21.2 x 16.3 x 21.1 26 7/8 3/82CXAB042AC3CUA 42,000 A TXVNB1 21.2 x 16.3 x 21.1 31 7/8 3/82CXAB048AC3CUA 48,000 A TXVNB1 25.3 x 16.3 x 21.1 36 7/8 3/82CXAC037AC3CUA 36,000 A TXVNB1 20.8 x 19.8 x 21.1 27 1 1 /8 3/82CXAC043AC3CUA 42,000 A TXVNB1 20.8 x 19.8 x 21.1 32 1 1 /8 3/82CXAC049AC3CUA 48,000 A TXVNB1 24.9 x 19.8 x 21.1 34 1 1 /8 3/82CXAC060AC3CUA 60,000 A TXVNB1 29.1 x 19.8 x 21.1 40 1 1 /8 3/82CXAD050AC3CUA 48,000 A TXVNB1 25.1 x 23.3 x 21.1 37 1 1 /8 3/82CXAD061AC3CUA 60,000 A TXVNB1 28.6 x 23.3 x 21.1 42 1 1 /8 3/8Table FUR-21-C — Cooling Only Uncased Coils (Upflow/ Downflow) R-410A Refriger<strong>an</strong>tNom. Cap. Overall Shipping Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Weight OD ODNumber (Btuh) Type Control H x W x D (Ibs.) Gas Liq.1/45/165/165/163/83/83/83/83/83/83/83/83/82/4CXA Coil Features:• Uncased upflow /downflowcooling only coils• Brazed fittings (left side)• Drain fitting (left side)• Non-Bleed TXV withmech<strong>an</strong>ical fittings.• Copper tube with Aluminumfins• Suction pressure serviceport• Split inner for easy coilcle<strong>an</strong>ing• 5 Year limited partswarr<strong>an</strong>ty4CXAA018AC3CUA 18,000 A TXVNB1 15.9 x 13.3 x 21.1 17 5/84CXAA024AC3CUA 24,000 A TXVNB1 17.6 x 13.3 x 21.1 20 3/44CXAB025AC3CUA 24,000 A TXVNB1 15.9 x 16.3 x 21.1 21 3/44CXAB031AC3CUA 30,000 A TXVNB1 15.9 x 16.3 x 21.1 26 3/44CXAB036AC3CUA 36,000 A TXVNB1 21.2 x 16.3 x 21.1 26 7/84CXAB042AC3CUA 42,000 A TXVNB1 21.2 x 16.3 x 21.1 31 7/84CXAB048AC3CUA 48,000 A TXVNB1 25.3 x 16.3 x 21.1 36 7/84CXAC037AC3CUA 36,000 A TXVNB1 20.8 x 19.8 x 21.1 27 1 1 /84CXAC043AC3CUA 42,000 A TXVNB1 20.8 x 19.8 x 21.1 32 1 1 /84CXAC049AC3CUA 48,000 A TXVNB1 24.9 x 19.8 x 21.1 34 1 1 /84CXAC060AC3CUA 60,000 A TXVNB1 29.1 x 19.8 x 21.1 40 1 1 /84CXAD050AC3CUA 48,000 A TXVNB1 25.1 x 23.3 x 21.1 37 1 1 /84CXAD061AC3CUA 60,000 A TXVNB1 28.6 x 23.3 x 21.1 42 1 1 /81 Start Kits may be required on outdoor unit.1/45/165/165/163/83/83/83/83/83/83/83/83/8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.FUR-21 Effective 1/1/06


High EfficiencySplit System – Cased/UncasedHeat Pump <strong>an</strong>d Cooling CoilsTable FUR-22-A — Brazed, Cased High Efficiency Heat Pump/Cooling Coils-(Upflow, Downflow orHorizontal Left Only) R-22 Refriger<strong>an</strong>tNom. Cap. Outlet Overall Shipping Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.TXC031S3HPC 30,000 A TXVNB1 15 5 /8 x 19 3 /8 22.5 x 17.5 x 21.5 54 3/4TXC036S3HPD 36,000 A TXVNB1 15 5 /8 x 19 3 /8 26.9 x 17.5 x 21.5 67 7/8TXC037S3HPD 36,000 A TXVNB1 19 1 /8 x 19 3 /8 26.9 x 21 x 21.5 70 7/8TXC054S3HPC 54,000 A TXVNB1 19 1 /8 x 19 3 /8 30.0 x 21 x 21.5 73 1 1 /8TXC065S3HPC 60,000 A TXVNB1 22 5 /8 x 19 11 /16 33.0* x 24.5 x 21.5 90 1 1 /85/163/83/83/83/8TXC ComfortCoil Features:• Split inner <strong>an</strong>d outer doorsfor easy coil cle<strong>an</strong>ing• Double sloped noncorrosive drain p<strong>an</strong>s-UL Rated 400°F• Suction pressure serviceport• 100% foil lined insulation• Easy case attachment tofurnace• 3 way application• Painted cabinet matchesfurnace• 5 Year limited partswarr<strong>an</strong>ty on all coils• Copper tube <strong>an</strong>dAluminum finRXC Comfort TM CoilFeatures• Refriger<strong>an</strong>t R-410A only• Split inner <strong>an</strong>d outerdoors for easy coilcle<strong>an</strong>ing• Double sloped noncorrosivedrain p<strong>an</strong>s(UL Rated 400 o F)• Suction pressureservice port• 100% foil lined insulation• Easy case attachmentto furnace• Painted cabinet matchesfurnace• 3 way application• 5-year limited partswarr<strong>an</strong>tyRXA Comfort TM CoilFeatures• Double sloped noncorrosivedrain p<strong>an</strong>(UL Rated 400 o F)• Suction pressureservice port• Easy access servicep<strong>an</strong>els• 5-year limited partswarr<strong>an</strong>tyTable FUR-22-B — Brazed, Cased Dual Circuit Cooling Only Coils-(Upflow, Downflow or Horizontal Left Only)Nom. Cap. Outlet Overall Shipping Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.TXC039E300C2 36,000 A TXVNB1 15 5 /8 x 19 5 /16 30 1 /16 x 17 1 /2 x 21 1 /2 69 3/4TXC059E300C2 59,000 A TXVNB1 19 1 /8 x 19 5 /16 30 1 /16 x 21 x 21 1 /2 73 7/8TXC062E300C2 64,000 A TXVNB1 22 5 /8 x 19 5 /16 30 1 /16 x 24 1 /2 x 21 1 /2 79 7/81 Start Kits may be required on outdoor unit.2 Only used with Variable Speed Gas Furnace to achieve 2-stage heat/cool.*Overall height. Actual height of case is 30".Table FUR-22-C — Comfort Coils Brazed Coils* (Upflow/Downflow/Horizontal Left Only)R-410A Refriger<strong>an</strong>tNom. Cap. Outlet Uncrated Shipping Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control Cased W/H x D H x W x D (Ibs.) Gas Liq.RXC025S3HPD 24,000 A TXVNB1 Full 15 5 /8 x 19 5 /16 17 5 /8 x 17 1 /2 x 21 1 /2 42 5/8RXC031S3HPC 30,000 A TXVNB1 Full 15 5 /8 x 19 5 /16 22 5 /8 x 17 1 /2 x 21 1 /2 54 3/4RXC036S3HPD 36,000 A TXVNB1 Full 15 5 /8 x 19 5 /16 26 7 /8 x 17 1 /2 x 21 1 /2 67 3/4RXC037S3HPD 36,000 A TXVNB1 Full 19 1 /8 x 19 5 /16 26 7 /8 x 21 x 21 1 /2 70 3/4RXC054S3HPC 54,000 A TXVNB1 Full 19 1 /8 x 19 5 /16 30 1 /16 x 21 x 21 1 /2 73 7/8RXC061S3HPC 60,000 A TXVNB1 Full 22 11 /16 x 19 5 /16 30 1 /16 x 24 1 /2 x 21 1 /2 77 7/8RXC065S3HPC 60,000 A TXVNB1 Partial 22 5 /8 x 19 5 /16 233 7 /8 x 24 1 /2 x 21 1 /2 94 7/8Table FUR-22-D — Brazed Uncased Coils* (Upflow/Downflow) R-410A Refriger<strong>an</strong>tNom. Cap. Uncrated Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Shipping OD ODNumber (Btuh) Type Control Cased H x W x D Weight (Ibs.) Gas Liq.RXA060S3HPC 60,000 A TXVNB1 None 28 x 19 9 /16 x 19 9 /16 46 3 3/4 /8RXA061S3HPC 60,000 A TXVNB1 None 27 7 /16 x 23 4 /16 x 19 9 /16 47 3 3/4 /81 Start Kits may be required on outdoor unit.2 Overall height. Actual height of case is 30". Downflow application of RXC065 requires field fabrication of case extension shown inthe Installer's Guide.Note: RXC, RXA <strong>an</strong>d RXH series coils include a reducing coupling to accept the smaller interconnecting suction line tubingrecommended with R-410A systemsTable FUR-22-E — Brazed, Cased Dual Circuit Cooling Only Coil23Nom. Cap. Outlet Overall Shipping Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.TXE120B500D 120,000 Flat TXV-B 18 3 /4 x 57 3 /4 26 x 64 x 25 235 1 1 /8 3/81 Start Kits may be required on outdoor unit.2 Coils are 3/8" cu/al plate fin.3 Two circuit cooling coil.5/163/83/85/165/163/83/83/83/83/8Effective 1/1/06FUR-22For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System – CasedHeat Pump <strong>an</strong>d Cooling CoilsTable FUR-23-A — Brazed, Cased Heat Pump/Cooling Coils-(Upflow, Downflow or Horizontal Left Only*)Nom. Cap. Outlet Overall Shipping Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.1 – 5 TonCased Coils• Split inner <strong>an</strong>d outerdoors for easy coilcle<strong>an</strong>ing• Double sloped noncorrosive drain p<strong>an</strong>s-UL Rated 400° F• Suction pressure serviceport• 100% foil lined insulation• External FCCV location• Easy case attachment tofurnace• 3 way application• Painted cabinet matchesfurnace• 5 year limited partswarr<strong>an</strong>ty on all coils• FCCV equipped coilscompatible with R-22 orR-410A refriger<strong>an</strong>t• Upflow, downflow orhorizontal left only(TXC-E/TXC-S)RXH Comfort TM CoilFeatures• Sloped non-corrosivedrain p<strong>an</strong> (UL Rated400 o F)• Bi-directional airflow• Galv<strong>an</strong>ized case -unpainted• Suction pressure port• 5-year limited partswarr<strong>an</strong>tyTXC018C4HPC 18,000 A .049 12 5 /8 x 19 3 /8 17 5 /8 x 14 1 /2 x 21 1 /2 32 5/8TXC024C4HPC 24,000 A .049 12 5 /8 x 19 3 /8 17 5 /8 x 14 1 /2 x 21 1 /2 34 3/4TXC025C4HPC 24,000 A .057 15 5 /8 x 19 3 /8 17 5 /8 x 17 1 /2 x 21 1 /2 39 3/4TXC030C4HPC 30,000 A .067 12 5 /8 x 19 3 /8 22 5 /8 x 14 1 /2 x 21 1 /2 37PHASED OUT3/4TXC031C4HPC 31,000 A .067 15 5 /8 x 19 3 /8 17 5 /8 x 17 1 /2 x 21 1 /2 43 3/4TXC035C4HPC 35,000 A .071 12 5 /8 x 19 3 /8 22 5 /8 x 14 1 /2 x 21 1 /2 37 7/8TXC036C4HPC 36,000 A .071 15 5 /8 x 19 3 /8 22 5 /8 x 17 1 /2 x 21 1 /2 51 7/8TXC037C4HPC 37,000 A .071 19 1 /8 x 19 3 /8 22 5 /8 x 21 x 21 1 /2 54 7/8TXC042C4HPC 42,000 A .080 15 5 /8 x 19 3 /8 22 5 /8 x 17 1 /2 x 21 1 /2 56 7/8TXC043C4HPC 43,000 A .080 19 1 /8 x 19 3 /8 22 5 /8 x 21 x 21 1 /2 57 1 1 /8TXC048C4HPD 48,000 A .083 15 5 /8 x 19 3 /8 26 7 /8 x 17 1 /2 x 21 1 /2 68 1 1 /8TXC049C4HPD 48,000 A .083 19 1 /8 x 19 3 /8 26 7 /8 x 21 x 21 1 /2 69 1 1 /8TXC050C4HPD 48,000 A .083 22 5 /8 x 19 5 /16 26 7 /8 x 24 1 /2 x 21 1 /2 69 1 1 /8TXC060C5HPC 60,000 A TXV-B 19 1 /8 x 19 3 /8 30 1 /16 x 21 x 21 1 /2 69 1 1 /8TXC061C5HPC 61,000 A TXV-B 22 5 /8 x 19 5 /16 30 1 /16 x 24 1 /2 x 21 1 /2 71 1 1 /8Table FUR-23-B —Brazed, Cased High Efficiency Heat Pump/Cooling Coils-(Upflow, Downflow orHorizontal Left Only*)Nom. Cap. Outlet Overall Shipping Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.PHASED OUTTXC031E5HPC 30,000 A TXV-B 15 5 /8 x 19 3 /8 22 5 /8 x 17 1 /2 x 21 1 /2 54 3/4TXC036E5HPD 36,000 A TXV-B 15 5 /8 x 19 3 /8 26 7 /8 x 17 1 /2 x 21 1 /2 67 7/8TXC037E5HPD 37,000 A TXV-B 19 1 /8 x 19 3 /8 26 7 /8 x 21 x 21 1 /2 70 7/8TXC054E5HPC 54,000 A TXV-B 19 1 /8 x 19 3 /8 30 1 /16 x 21 x 21 1 /2 73 1 1 /8Table FUR-23-C — Brazed,Cased Heat Pump/Cooling Coils-(Upflow, Downflow or Horizontal Left or Right)Nom. Cap. Outlet Overall Shipping Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.TXC024D4HPC 24,000 A .057 12 5 /8 x 19 3 /8 30 1 /16 x 14 1 /2 x 21 1 /2 42PHASED OUT3/4TXC025D4HPC 24,000 A .057 15 5 /8 x 19 3 /8 30 1 /16 x 17 1 /2 x 21 1 /2 48 3/4 5/16TXC030D4HPC 30,000 A .067 12 5 /8 x 19 3 /8 30 1 /16 x 14 1 /2 x 21 1 /2 46 3/4 5/16TXC031D4HPC 30,000 A .067 15 5 /8 x 19 3 /8 30 1 /16 x 17 1 /2 x 21 1 /2 52 3/4 5/16TXC035D4HPC 35,000 A .071 12 5 /8 x 19 3 /8 30 1 /16 x 14 1 /2 x 21 1 /2 46 7/8 3/8TXC036D4HPC 36,000 A .071 15 5 /8 x 19 3 /8 30 1 /16 x 17 1 /2 x 21 1 /2 60 7/8 3/8* TXC series coils include a reducing coupling to accept the smaller interconnecting suction line tubing recommended with R-410Asystems.Table FUR-23-D — Horizontal Only Cased Coil* R-410A Refriger<strong>an</strong>tNom. Cap. Uncrated Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Shipping OD ODNumber (Btuh) Type Control Cased H x W x D Weight (Ibs.) Gas Liq.RXH063S3HPB PHASED 63,500OUT Flat TXVNB1 PHASED Full OUT 28PHASED 3 /4 x 10 1 /4 x 37 1 OUT /2 79PHASED 3/4 OUT 3/8Table FUR-23-E — Cased Horizontal OnlyNom. Cap. Duct Con. Uncrated Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Dim. (in.) Shipping OD ODNumber (Btuh) Type Control H x W H x W x D Weight (Ibs.) Gas Liq.PHASED OUTTXH025A4HPA 27,000 Flat .057 21 x 24 22 x 10 x 28 40 3/4TXH033A4HPA 34,000 Flat .057 21 x 24 22 x 10 x 28 46 3/4TXH041A4HPA 44,000 Flat .067 21 x 33 1 /4 22 x 10 x 37 56 7/8TXH054A4HPA 58,000 Flat .083 21 x 33 1 /4 22 x 10 x 37 64 7/8TXH063P3HPB 61,000 Flat TXVNB1 27 x 33 1 /4 28 x 10 x 37 79 7/81 Start Kits may be required on outdoor unit.* RXH series coils include a reducing coupling to accept the smaller interconnecting suction line tubing recommended with R-410Asystems.1/45/165/165/165/163/83/83/83/83/83/83/83/83/83/85/163/83/83/85/165/163/83/83/83/8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.FUR-23 Effective 1/1/06


Split System – Cased/UncasedHeat Pump <strong>an</strong>d Cooling CoilsTable FUR-24-A — Brazed, Uncased Heat Pump/Cooling Coils (Upflow/Downflow)Nom. Cap. Uncrated Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Shipping OD ODNumber (Btuh) Type Control Cased H x W x D Weight (Ibs.) Gas Liq.1 – 5 TonUncased Coils• 5-year limited partswarr<strong>an</strong>ty• FCCV equipped coilscompatible with R-22 orR-410A refriger<strong>an</strong>tTXA018C4HPC 18,000 A .049 No 15 5 /16 x 13 1 /16 x 19 9 /16 15 5/8TXA024C4HPC 24,000 A .049 No 16 5 /8 x 13 1 /16 x 19 9 /16 18 3/4TXA025C4HPC 24,000 A .057 No 15 1 /8 x 16 1 /16 x 19 9 /16 20 3/4TXA030C4HPC 30,000 A .067 No 19 3 /4 x 13 1 /16 x 19 9 /16 23 3/4TXA031C4HPC 30,000 A .067 No 16 x 16 1 /16 x 19 9 /16 24PHASED OUT3/4TXA035C4HPC 35,000 A .071 No 19 3 /4 X 13 1 /16 X 19 9 /16 23 7/8TXA036C4HPC 36,000 A .071 No 19 1 /8 x 16 1 /16 x 19 9 /16 29 7/8TXA037C4HPC 36,000 A .071 No 18 9 /16 x 19 9 /16 x 19 9 /16 29 7/8TXA042C4HPC 42,000 A .080 No 21 1 /4 x 16 1 /16 x 19 9 /16 34 7/8TXA043C4HPC 42,000 A .080 No 20 11 /16 x 19 9 /16 x 19 9 /16 32 7/8TXA048C4HPC 48,000 A .083 No 25 5 /16 x 16 1 /16 x 19 9 /16 39 1 1 /8TXA049C4HPC 48,000 A .083 No 24 7 /8 x 19 9 /16 x 19 9 /16 37 1 1 /8TXA050C4HPC 48,000 A .083 No 24 3 /8 x 23 1 /16 x 19 9 /16 38 1 1 /8TXA060C5HPC 60,000 A TXV - B No 28 x 19 9 /16 x 19 9 /16 43 1 1 /8TXA061C5HPC 60,000 A TXV - B No 27 7 /16 x 23 1 /16 x 19 9 /16 44 1 1 /81/45/165/165/165/165/163/83/83/83/83/83/83/83/83/8Table FUR-24-B — Brazed Cased (Upflow Only)Nom. Cap. Outlet Uncrated Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Dim. (in.) Shipping OD ODNumber (Btuh) Type Control H x W H x W x D Weight (Ibs.) Gas Liq.1 1 /2 – 5 TonCased & Uncased• Cased <strong>an</strong>d uncased upflowcooling only coils• Brazed fittings (left side)• Drain fitting (left side)• Fixed orifice flow control(except CCBD60A5ACD,CUBD60A5ACD-TXV-B)• Shipped vertical upflowonly• Painted coil case• Suction pressure serviceport• 100% foil lined insulation• Split inner <strong>an</strong>d outer doorsfor easy coil cle<strong>an</strong>ing• 5 year limited partswarr<strong>an</strong>tyCCBA18A4ACD 18,000 A FIXED 12 5 /8 x 19 3 /8 17 5 /8 x 14 1 /2 x 21 1 /2 30 5/8CCBA24A4ACD 24,000 A FIXED 12 5 /8 x 19 3 /8 17 5 /8 x 14 1 /2 x 21 1 /2 32PHASED OUT3/4CCBA30A4ACD 30,000 A FIXED 12 5 /8 x 19 3 /8 17 5 /8 x 14 1 /2 x 21 1 /2 32 3/4CCBA36A4ACD 36,000 A FIXED 12 5 /8 x 19 3 /8 22 5 /8 x 14 1 /2 x 21 1 /2 35 3/4CCBB30A4ACD 30,000 A FIXED 15 5 /8 x 19 3 /8 17 5 /8 x 17 1 /2 x 21 1 /2 41 3/4CCBB36A4ACD 36,000 A FIXED 15 5 /8 x 19 3 /8 17 5 /8 x 17 1 /2 x 21 1 /2 41 3/4CCBB42A4ACD 42,000 A FIXED 15 5 /8 x 19 3 /8 22 5 /8 x 17 1 /2 x 21 1 /2 49 3/4CCBB48A4ACD 48,000 A FIXED 15 5 /8 x 19 3 /8 22 5 /8 x 17 1 /2 x 21 1 /2 54 3/4CCBC48A4ACD 48,000 A FIXED 19 1 /8 x 19 3 /8 22 5 /8 x 21 x 21 1 /2 55 3/4CCBC60A4ACE 60,000 A FIXED 19 1 /8 x 19 3 /8 26 7 /8 x 21 x 21 1 /2 67 7/8CCBD60A5ACD 60,000 A TXV-B 22 5 /8 x 19 5 /16 30 1 /16 x 24 1 /2 x 21 1 /2 69 7/8Table FUR-24-C — Brazed Uncased (Upflow Only)Nom. Cap. Uncrated Line SizeModel Cooling Coil Refriger<strong>an</strong>t Dim. (in.) Shipping OD ODNumber (Btuh) Type Control Cased H x W x D Weight (Ibs.) Gas Liq.CUBA18A4ACD 18,000 A FIXED No 11 1 /2 x 13 1 /16 x 19 9 /16 15 5/8 5/16CUBA24A4ACD 24,000 A FIXED No 14 5 /8 x 13 1 /16 x 19 9 /16 18 3/4 5/16CUBA30A4ACD 30,000 A FIXED No 14 5 /8 x 13 1 /16 x 19 9 /16 18 3/4CUBA36A4ACD 36,000 A FIXED No 19 3 /4 x 13 1 /16 x 19 9 /16 18PHASED OUT3/4CUBB24A4ACD 24,000 A FIXED No 15 3 /16 x 16 1 /16 x 19 9 /16 23 3/4CUBB30A4ACD 30,000 A FIXED No 16 x 16 1 /16 x 19 9 /16 24 3/4CUBB36A4ACD 36,000 A FIXED No 16 x 16 1 /16 x 19 9 /16 24 3/4CUBB42A4ACD 42,000 A FIXED No 19 1 /8 x 16 1 /16 x 19 9 /16 24 3/4CUBB48A4ACD 48,000 A FIXED No 21 1 /4 x 16 1 /16 x 19 9 /16 29 3/4CUBC36A4ACD 36,000 A FIXED No 16 5 /16 x 19 9 /16 x 19 9 /16 27 3/4CUBC42A4ACD 42,000 A FIXED No 18 9 /16 x 19 9 /16 x 19 9 /16 34 3/4CUBC48A4ACD 48,000 A FIXED No 20 11 /16 x 19 9 /16 x 19 9 /16 32 3/4CUBC60A4ACD 60,000 A FIXED No 24 7 /8 x 19 9 /16 x 19 9 /16 31 7/8CUBD48A4ACD 48,000 A FIXED No 20 5 /8 x 23 1 /16 x 19 9 /16 37 3/4CUBD60A5ACD 60,000 A TXV-B No 27 7 /16 x 23 1 /16 x 19 9 /16 44 3/45/165/165/165/165/163/83/85/163/83/83/83/83/85/165/165/165/165/165/163/83/83/83/83/8Effective 1/1/06FUR-24For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Split System – UncasedCoil EnclosuresTable FUR-25-A — Coil EnclosuresModel Coils Cooling or Used With Furnaces Outlet Dimensions (in) Dimensions (in.) ShippingNumber Heat Pump Flush on Both Sides W/H x D H x W x D Weight (Ibs.)BAYCLE1400C TXA018C4 14 1 /2" Wide Furnaces 12 5 /8 x 19 5 /16 22 1 /2 x 14 1 /2 x 21 1 /2 12TXA024C4TXA030C4BAYCLE1700C TXA025C4 17 1 /2" Wide Furnaces 15 5 /8 x 19 5 /16 22 1 /2 x 17 1 /2 x 21 1 /2 14TXA031C4TXA035C4TXA036C4TXA042C4TXA048C4BAYCLE2100C TXA037C4 21" Wide Furnaces 19 1 /8 x 19 5 /16 30 x 21 x 21 1 /2 18TXA043C4TXA049C4TXA060C5RXA060S3BAYCLE2400C TXA061C5 24 1 /2" Wide Furnaces 22 5 /8 x 19 5 /16 30 x 24 1 /2 x 21 1 /2 22RXA061S3Table FUR-25-B — 13 SEER Coil EnclosuresModel Used With Furnaces Dimensions (in.) ShippingNumber Coils Cooling or Heat Pump Flush on Both Sides H x W x D Weight (Ibs.)BAYCLE14A1422A 2/4CXAA018AC3CUA TXA018C4 14 1 /2" Wide Furnace 22 1 /2 x 14 1 /2 x 21 1 /2 122/4CXAA024AC3CUA TXA024C4TXA030C4BAYCLE17A1722A 2/4CXAB025AC3CUA TXA025C4 17 1 /2" Wide Furnace 22 5 /8 x 17 1 /2 x 21 1 /2 142/4CXAB031AC3CUA TXA031C42/4CXAB036AC3CUA TXA035C42/4CXAB042AC3CUA TXA036C42/4CXAB048AC3CUA TXA042C4TXA048C4BAYCLE21A2130A 2/4CXAC037AC3CUA TXA037C4 21" Wide Furnace 30 x 21 x 21 1 /2 182/4CXAC043AC3CUA TXA043C42/4CXAC049AC3CUA TXA049C42/4CXAC060AC3CUA TXA060C5RXA060S3BAYCLE24A2430A 2/4CXAD050AC3CUA TXA061C5 24 1 /2" Wide Furnace 30 x 24 1 /2 x 21 1 /2 222/4CXAD061AC3CUA RXA061S3Table FUR-25-C — Comfort TM Coil Door KitsModel Number Case Height Used WithBAYCCKT1750A 17.5 TXC018,024,025,031-C-A,BBAYCCKT2250A 22.5 TXC030,035,036,037,042,043-C-A,BTXC031-E/S-A,BBAYCCKT3000A 30.0 TXC048,049,050,060,061-C-A,BTXC036,037,054,065-E/S-A,BFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.FUR-25 Effective 1/1/06


Furnace/CoilsMatrixXL 90, XV 90 & CoilsFurnace Cabinet Matching Matching Furnace Cabinet Matching MatchingModel Width Cased Coils Uncased Coils Model Width Cased Coils Uncased CoilsTUX060R936W 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C TDX060R936W 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025CTUX080R942W 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C TDX080R942W 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C2CXCB036A TXC036C 2CXAB036A TXA036C 2CXCB036A TXC036C 2CXAB036A TXA036C2CXCB042A TXC042C 2CXAB042A TXA042C 2CXCB042A TXC042C 2CXAB042A TXA042C2CXCB048A TXC048C 2CXAB048A TXA048C 2CXCB048A TXC048C 2CXAB048A TXA048C2TXCB025A TXC025D 2TXCB025A TXC025D2TXCB031A TXC031D 2TXCB031A TXC031D2TXCB036A TXC036D 2TXCB036A TXC036D2TXCB042A TXC031E 2TXCB042A TXC031E2TXCB048A TXC036E 2TXCB048A TXC036E4CXCB025A TXC031S 4CXCB025A TXC031S4CXCB031A TXC036S 4CXCB031A TXC036S4CXCB036A RXC025S 4CXCB036A RXC025S4CXCB042A RXC031S 4CXCB042A RXC031S4CXCB048A RXC036S 4CXCB048A RXC036S4TXCB025A CUBB24A 4TXCB025A4TXCB031A CCBB30A CUBB30A 4TXCB031A4TXCB036A CCBB36A CUBB36A 4TXCB036A4TXCB042A CCBA42A CUBB42A 4TXCB042A4TXCB048A CCBA48A CUBB48A 4TXCB048ATUX100R948W 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDX100R948W 21" 2CXCC037A TXC037C 2CXAC037A TXA037C2CXCC043A TXC043C 2CXAC043A TXA043C 2CXCC043A TXC043C 2CXAC043A TXA043C2CXCC049A TXC049C 2CXAC049A TXA049C 2CXCC049A TXC049C 2CXAC049A TXA049C2CXCC060A TXC060C 2CXAC060A TXA060C 2CXCC060A TXC060C 2CXAC060A TXA060C2TXCC037A TXC037E 2TXCC037A TXC037E2TXCC043A TXC054E 2TXCC043A TXC054E2TXCC049A TXC037S 2TXCC049A TXC037S2TXCC054A TXC054S 2TXCC054A TXC054S2TXCC060A RXC037S 2TXCC060A RXC037S4CXCC037A RXC054S4CXCC037A RXC054S4CXCC043A CUBC36A 4CXCC043A4CXCC049A CUBC42 A 4CXCC049A4CXCC060A CCBC48A CUBC48A 4CXCC060A4TXCC037A CCBC60A CUBC60A 4TXCC037A4TXCC043A4TXCC043A4TXCC049A4TXCC049A4TXCC054A4TXCC054A4TXCC060A4TXCC060ATUX120R960W 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDX120R960W 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C2CXCD061A TXC061C 2CXAD061A TXA061C 2CXCD061A TXC061C 2CXAD061A TXA061C2TXCD050A TXC065S1 2TXCD050A TXC065S12TXCD061A RXC061S 2TXCD061A RXC061S2TXCD065A RXC065S1 2TXCD065A RXC065S14CXCD050A CUBD48A 4CXCD050A4CXCD061A CCBD60A CUBD60A 4CXCD061A4TXCD050A4TXCD050A4TXCD061A4TXCD061A4TXCD065A4TXCD065ATUY060R9V3W 17.5" TXC031E TDY060R9V3W 17.5" TXC031ETUY080R9V3W 17.5" TXC036E TDY080R9V3W 17.5" TXC036ETXC031STXC031STXC036STXC036SRXC025SRXC025SRXC031SRXC031SRXC036SRXC036STUY100R9V4W 21" TXC037E TDY100R9V4W 21" TXC037ETXC054ETXC054ETXC037STXC037STXC054STXC054SRXC037SRXC037SRXC054SRXC054STUY120R9V5W 24.5" TXC065S1 TDY120R9V5W 24.5" TXC065S1RXC061SRXC061SRXC065S1RXC065S1NOTE: For reference only on Flush Fit Applications1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).Effective 1/1/06FUR-26For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Furnace/CoilsMatrixXT 90 & CoilsMatching Matching Matching MatchingFurnace Cabinet Cased Uncased Furnace Cabinet Cased UncasedModel Width Coils Coils Model Width Coils CoilsTUX1B040A9H21A 17.5" 2CXCB025A 2CXAB025A TDX1B040A9H31A 17.5" 2CXCB025A 2CXAB025ATUX1B060A9H31A 17.5" 2CXCB031A 2CXAB031A TDX1B060A9H31A 17.5" 2CXCB031A 2CXAB031ATUX1B080A9H31A 17.5" 2CXCB036A 2CXAB036A TDX1B080A9H31A 17.5" 2CXCB036A 2CXAB036A2CXCB042A 2CXAB042A 2CXCB042A 2CXAB042A2CXCB048A 2CXAB048A 2CXCB048A 2CXAB048A2TXCB025A2TXCB025A2TXCB031A2TXCB031A2TXCB036A2TXCB036A2TXCB042A2TXCB042A2TXCB048A2TXCB048A4CXCB025A4CXCB025A4CXCB031A4CXCB031A4CXCB036A4CXCB036A4CXCB042A4CXCB042A4CXCB048A4CXCB048A4TXCB025A4TXCB025A4TXCB031A4TXCB031A4TXCB036A4TXCB036A4TXCB042A4TXCB042A4TXCB048A4TXCB048ATUX1C100A9H41A 21" 2CXCC037A 2CXAC037A TDX1C100A9H41A 21" 2CXCC037A 2CXAC037A2CXCC043A 2CXAC043A 2CXCC043A 2CXAC043A2CXCC049A 2CXAC049A 2CXCC049A 2CXAC049A2CXCC060A 2CXAC060A 2CXCC060A 2CXAC060A2TXCC037A2TXCC037A2TXCC043A2TXCC043A2TXCC049A2TXCC049A2TXCC054A2TXCC054A2TXCC060A2TXCC060A4CXCC037A4CXCC037A4CXCC043A4CXCC043A4CXCC049A4CXCC049A4CXCC060A4CXCC060A4TXCC037A4TXCC037A4TXCC043A4TXCC043A4TXCC049A4TXCC049A4TXCC054A4TXCC054A4TXCC060A4TXCC060ATUX1D120A9H51A 24.5" 2CXCD050A 2CXAD050A TDX1D120A9H51A 24.5" 2CXCD050A 2CXAD050A2CXCD061A 2CXAD061A 2CXCD061A 2CXAD061A2TXCD050A2TXCD050A2TXCD061A2TXCD061A2TXCD065A2TXCD065A4CXCD050A4CXCD050A4CXCD061A4CXCD061A4TXCD050A4TXCD050A4TXCD061A4TXCD061A4TXCD065A4TXCD065ANOTE: For reference only on Flush Fit ApplicationsFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.FUR-27 Effective 1/1/06


Furnace/CoilsMatrixXR 90 & CoilsFurnace Cabinet Matching Matching Furnace Cabinet Matching MatchingModel Width Cased Coils Uncased Coils Model Width Cased Coils Uncased CoilsTUX040C924D 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C TDX040C924D 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025CTUX060C936D 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C TDX060C936D 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031CTUX080C942D 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036C TDX080C942D 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036CTUX1B040A9241A 17.5" 2CXCB042A TXC042C 2CXAB042A TXA042C TDX1B040A9241A 17.5" 2CXCB042A TXC042C 2CXAB042A TXA042CTUX1B060A9361A 17.5" 2CXCB048A TXC048C 2CXAB048A TXA048C TDX1B060A9361A 17.5" 2CXCB048A TXC048C 2CXAB048A TXA048CTUX1B080A9421A 17.5" 2TXCB025A TXC025D TDX1B080A9421A 17.5" 2TXCB025A TXC025D2TXCB031A TXC031D 2TXCB031A TXC031D2TXCB036A TXC036D 2TXCB036A TXC036D2TXCB042A TXC031E 2TXCB042A TXC031E2TXCB048A TXC036E 2TXCB048A TXC036E4CXCB025A TXC031S 4CXCB025A TXC031S4CXCB031A TXC036S 4CXCB031A TXC036S4CXCB036A RXC025S 4CXCB036A RXC025S4CXCB042A RXC031S 4CXCB042A RXC031S4CXCB048A RXC036S 4CXCB048A RXC036S4TXCB025A CUBB24A 4TXCB025A4TXCB031A CCBB30A CUBB30A 4TXCB031A4TXCB036A CCBB36A CUBB36A 4TXCB036A4TXCB042A CCBA42A CUBB42A 4TXCB042A4TXCB048A CCBA48A CUBB48A 4TXCB048ATUX080C960D 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDX100C948D 21" 2CXCC037A TXC037C 2CXAC037A TXA037CTUX100C948D 21" 2CXCC043A TXC043C 2CXAC043A TXA043C TDX1C100A9481A 21" 2CXCC043A TXC043C 2CXAC043A TXA043CTUX1C080A9601A 21" 2CXCC049A TXC049C 2CXAC049A TXA049C 2CXCC049A TXC049C 2CXAC049A TXA049CTUX1C100A9481A 21" 2CXCC060A TXC060C 2CXAC060A TXA060C 2CXCC060A TXC060C 2CXAC060A TXA060C2TXCC037A TXC037E 2TXCC037A TXC037E2TXCC043A TXC054E 2TXCC043A TXC054E2TXCC049A TXC037S 2TXCC049A TXC037S2TXCC054A TXC054S 2TXCC054A TXC054S2TXCC060A RXC037S 2TXCC060A RXC037S2TXCC037A RXC054S 2TXCC037A RXC054S4CXCC043A CUBC36A 4CXCC043A4CXCC049A CUBC42 A 4CXCC049A4CXCC060A CCBC48A CUBC48A 4CXCC060A4TXCC037A CCBC60A CUBC60A 4TXCC037A4TXCC043A4TXCC043A4TXCC049A4TXCC049A4TXCC054A4TXCC054A4TXCC060A4TXCC060ATUX100C960D 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDX120C960D 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060CTUX120C960D 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C TDX1D120A9601A 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061CTUX1D100A9601A 2TXCD050A TXC065S1 2TXCD050A TXC065S1TUX1D120A9601A 2TXCD061A RXC061S 2TXCD061A RXC061S2TXCD065A RXC065S1 2TXCD065A RXC065S14CXCD050A CUBD48A 4CXCD050A4CXCD061A CCBD60A CUBD60A 4CXCD061A4TXCD050A4TXCD050A4TXCD061A4TXCD061A4TXCD065A4TXCD065ANOTE: For reference only on Flush Fit Applications1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).Effective 1/1/06FUR-28For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Furnace/CoilsMatrixXB 90 & CoilsFurnace Cabinet Matching Matching Furnace Cabinet Matching MatchingModel Width Cased Coils Uncased Coils Model Width Cased Coils Uncased CoilsTUC040C924B 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C TDC040C924B 17.5" 2CXCB025A TXC025C TXA025CTUC060C936B 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C TDC060C936B 17.5" 2CXCB031A TXC031C TXA031CTUC080C942B 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036C TDC080C942B 17.5" 2CXCB036A TXC036C TXA036C2CXCB042A TXC042C 2CXAB042A TXA042C 2CXCB042A TXC042C TXA042C2CXCB048A TXC048C 2CXAB048A TXA048C 2CXCB048A TXC048C TXA048C2TXCB025A TXC025D 2TXCB025A TXC025D2TXCB031A TXC031D 2TXCB031A TXC031D2TXCB036A TXC036D 2TXCB036A TXC036D2TXCB042A TXC031E 2TXCB042A TXC031E2TXCB048A TXC036E 2TXCB048A TXC036E4CXCB025A TXC031S 4CXCB025A TXC031S4CXCB031A TXC036S 4CXCB031A TXC036S4CXCB036A RXC025S 4CXCB036A RXC025S4CXCB042A RXC031S 4CXCB042A RXC031S4CXCB048A RXC036S 4CXCB048A RXC036S4TXCB025A CUBB24A 4TXCB025A4TXCB031A CCBB30A CUBB30A 4TXCB031A4TXCB036A CCBB36A CUBB36A 4TXCB036A4TXCB042A CCBA42A CUBB42A 4TXCB042A4TXCB048A CCBA48A CUBB48A 4TXCB048ATUC100C948B 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDC100C948B 21" 2CXCC037A TXC037C TXA037C2CXCC043A TXC043C 2CXAC043A TXA043C 2CXCC043A TXC043C TXA043C2CXCC049A TXC049C 2CXAC049A TXA049C 2CXCC049A TXC049C TXA049C2CXCC060A TXC060C 2CXAC060A TXA060C 2CXCC060A TXC060C TXA060C2TXCC037A TXC037E 2TXCC037A TXC037E2TXCC043A TXC054E 2TXCC043A TXC054E2TXCC049A TXC037S 2TXCC049A TXC037S2TXCC054A TXC054S 2TXCC054A TXC054S2TXCC060A RXC037S 2TXCC060A RXC037S4CXCC037A RXC054S4CXCC037A RXC054S4CXCC043A CUBC36A 4CXCC043A4CXCC049A CUBC42 A 4CXCC049A4CXCC060A CCBC48A CUBC48A 4CXCC060A4TXCC037A CCBC60A CUBC60A 4TXCC037A4TXCC043A4TXCC043A4TXCC049A4TXCC049A4TXCC054A4TXCC054A4TXCC060A4TXCC060ATUC100C960B 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDC120C960B 24.5" 2CXCD050A TXC050C TXA060CTUC120C960B 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C 2CXCD061A TXC061C TXA061C2TXCD050A TXC065S1 2TXCD050A TXC065S12TXCD061A RXC061S 2TXCD061A RXC061S2TXCD065A RXC065S1 2TXCD065A RXC065S14CXCD050A CUBD48A 4CXCD050A4CXCD061A CCBD60A CUBD60A 4CXCD061A4TXCD050A4TXCD050A4TXCD061A4TXCD061A4TXCD065A4TXCD065ANOTE: For reference only on Flush Fit Applications1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.FUR-29 Effective 1/1/06


Furnace/CoilsMatrixXV 80 & CoilsFurnace Cabinet Matching Matching Furnace Cabinet Matching MatchingModel Width Cased Coils Uncased Coils Model Width Cased Coils Uncased CoilsTUD060R9V3K 17.5" TXC031E TDD060R9V3F 17.5" TXC031ETUD080R9V3K 17.5" TXC036E TDD080R9V3F 17.5" TXC036ETUD100R9V3K TXC031S TXC031STXC036STXC036SRXC025SRXC025SRXC031SRXC031SRXC036SRXC036STUD080R9V4K 21" TXC054E TDD100R9V5F 21" TXC037ETUD100R9V5K 21" TXC037E TXC054ETXC037STXC037STXC054STXC054SRXC037SRXC037SRXC054SRXC054STUD120R9V5K 24.5" TXC065S1 TDD120R9V5F 24.5" TXC065S1TUD140R9V5K 24.5" RXC061S RXC061SRXC065S1RXC065S1NOTE: For reference only on Flush Fit Applications1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).Effective 1/1/06FUR-30For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Furnace/CoilsMatrixXL 80 & CoilsFurnace Cabinet Matching Matching Furnace Cabinet Matching MatchingModel Width Cased Coils Uncased Coils Model Width Cased Coils Uncased CoilsTUD040R924K 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018C TDD040R924F 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018CTUD060R936K 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024C TDD060R936F 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024C2TXCA018A TXC030C TXA030C 2TXCA018A TXC030C TXA030C2TXCA024A TXC035C TXA035C 2TXCA024A TXC035C TXA035C4CXCA018A TXC024D 4CXCA018A TXC024D4CXCA024A TXC030D 4CXCA024A TXC030D4TXCA018A TXC035D 4TXCA018A TXC035D4TXCA024A CCBA18A CUBA18A 4TXCA024ACCBA24ACUBA24ACCBA30ACUBA30ACCBA36ACUBA36ATUD060R937K 17.5" 2CXCB025A TXC025C 2CXAB025A TDD060R937F 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025CTUD080R936K 17.5" 2CXCB031A TXC031C 2CXAB031A TDD080R936F 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031CTUD080R948K 17.5" 2CXCB036A TXC036C 2CXAB036A TDD100R945F 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036CTUD100R936K 17.5" 2CXCB042A TXC042C 2CXAB042A TXA025C 2CXCB042A TXC042C 2CXAB042A TXA042C2CXCB048A TXC048C 2CXAB048A TXA031C 2CXCB048A TXC048C 2CXAB048A TXA048C2TXCB025A TXC025D TXA036C 2TXCB025A TXC025D2TXCB031A TXC031D TXA042C 2TXCB031A TXC031D2TXCB036A TXC036D TXA048C 2TXCB036A TXC036D2TXCB042A TXC031E 2TXCB042A TXC031E2TXCB048A TXC036E 2TXCB048A TXC036E4CXCB025A TXC031S 4CXCB025A TXC031S4CXCB031A TXC036S 4CXCB031A TXC036S4CXCB036A RXC025S 4CXCB036A RXC025S4CXCB042A RXC031S 4CXCB042A RXC031S4CXCB048A RXC036S 4CXCB048A RXC036S4TXCB025A CUBB24A 4TXCB025A4TXCB031A CCBB30A CUBB30A 4TXCB031A4TXCB036A CCBB36A CUBB36A 4TXCB036A4TXCB042A CCBA42A CUBB42A 4TXCB042A4TXCB048A CCBA48A CUBB48A 4TXCB048ATUD100R948K 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDD100R948F 21" 2CXCC037A TXC037C 2CXAC037A TXA037CTUD100R960K 21" 2CXCC043A TXC043C 2CXAC043A TXA043C TDD100R960F 21" 2CXCC043A TXC043C 2CXAC043A TXA043C2CXCC049A TXC049C 2CXAC049A TXA049C 2CXCC049A TXC049C 2CXAC049A TXA049C2CXCC060A TXC060C 2CXAC060A TXA050C 2CXCC060A TXC060C 2CXAC060A TXA050C2TXCC037A TXC037E 2TXCC037A TXC037E2TXCC043A TXC054E 2TXCC043A TXC054E2TXCC049A TXC037S 2TXCC049A TXC037S2TXCC054A TXC054S 2TXCC054A TXC054S2TXCC060A RXC037S 2TXCC060A RXC037S4CXCC037A RXC054S4CXCC037A RXC054S4CXCC043A CUBC36A4CXCC043A4CXCC049A CUBC42A 4CXCC049A4CXCC060A CCBC48A CUBC48A 4CXCC060A4TXCC037A CCBC60A CUBC60A 4TXCC037A4TXCC043A4TXCC043A4TXCC049A4TXCC049A4TXCC054A4TXCC054A4TXCC060A4TXCC060ATUD120R960K 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDD120R960F 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060CTUD140R960K 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C TDD140R960F 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C2TXCD050A TXC065S1 2TXCD050A TXC065S12TXCD061A RXC061S 2TXCD061A RXC061S2TXCD065A RXC065S1 2TXCD065A RXC065S14CXCD050A CUBD48A 4CXCD050A4CXCD061A CCBD60A CUBD60A 4CXCD061A4TXCD050A4TXCD050A4TXCD061A4TXCD061A4TXCD065A4TXCD065ANOTE: For reference only on Flush Fit Applications1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.FUR-31 Effective 1/1/06


Furnace/CoilsMatrixXT 80 & CoilsMatching Matching Matching MatchingFurnace Cabinet Cased Height Uncased Height Furnace Cabinet Cased Height Uncased HeightModel Width Coils Inches Coils Inches Model Width Coils Inches Coils InchesTUD1A040A9H21A 14.5" 2CXCA018A 2CXAA018A2CXCA024A2CXAA024A2TXCA018A2TXCA024A2TXCA024A4CXCA018A4CXCA024A4TXCA018A4TXCA024ATUD1B060A9H31A 17.5" 2CXCB025A 2CXAB025A TDD1B060A9H31A 17.5" 2CXCB025A 2CXAB025ATUD1B080A9H31A 17.5" 2CXCB031A 2CXAB031A TDD1B080A9H31A 17.5" 2CXCB031A 2CXAB031ATUD1B100A9H31A 17.5" 2CXCB036A 2CXAB036A 2CXCB036A 2CXAB036A2CXCB042A 2CXAB042A 2CXCB042A 2CXAB042A2CXCB048A 2CXAB048A 2CXCB048A 2CXAB048A2TXCB025A2TXCB025A2TXCB031A2TXCB031A2TXCB036A2TXCB036A2TXCB042A2TXCB042A2TXCB048A2TXCB048A4CXCB025A4CXCB025A4CXCB031A4CXCB031A4CXCB036A4CXCB036A4CXCB042A4CXCB042A4CXCB048A4CXCB048A4TXCB025A4TXCB025A4TXCB031A4TXCB031A4TXCB036A4TXCB036A4TXCB042A4TXCB042A4TXCB048A4TXCB048ATUD1C080A9H41A 21" 2CXCC037A 2CXAC037A TDD1C100A 21" 2CXCC037A 2CXAC037ATUD1C100A9H51A 21" 2CXCC043A 2CXAC043A 2CXCC043A 2CXAC043A2CXCC049A 2CXAC049A 2CXCC049A 2CXAC049A2CXCC060A 2CXAC060A 2CXCC060A 2CXAC060A2TXCC037A2TXCC037A2TXCC043A2TXCC043A2TXCC049A2TXCC049A2TXCC054A2TXCC054A2TXCC060A2TXCC060A4CXCC037A4CXCC037A4CXCC043A4CXCC043A4CXCC049A4CXCC049A4CXCC060A4CXCC060A4TXCC037A4TXCC037A4TXCC043A4TXCC043A4TXCC049A4TXCC049A4TXCC054A4TXCC054A4TXCC060A4TXCC060ATUD1D120A9H51A 24.5" 2CXCD050A 2CXAD050A TDD1D120A 24.5" 2CXCD050A 2CXAD050ATUD1D140A9H51A 24.5" 2CXCD061A 2CXAD061A 2CXCD061A 2CXAD061A2TXCD050A2TXCD050A2TXCD061A2TXCD061A2TXCD065A2TXCD065A4CXCD050A4CXCD050A4CXCD061A4CXCD061A4TXCD050A4TXCD050A4TXCD061A4TXCD061A4TXCD065A4TXCD065ANOTE: For reference only on Flush Fit ApplicationsEffective 1/1/06FUR-32For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Furnace/CoilsMatrixXR 80 & CoilsFurnace Cabinet Matching Matching Furnace Cabinet Matching MatchingModel Width Cased Coils Uncased Coils Model Width Cased Coils Uncased CoilsTUD040C924K 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018C TDD040C924F 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018CTUD040C930K 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024C TDD060C936F 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024CTUD060C924K 14.5" 2TXCA018A TXC030C TXA030C TDD060C936F 14.5" 2TXCA018A TXC030C TXA030CTUD060C936K 14.5" 2TXCA024A TXC035C TXA035C TDD1A040A9241A 14.5" 2TXCA024A TXC035C TXA035CTUD1A040A9241A 14.5" 4CXCA018A TXC024D TDD1A060A9241A 14.5" 4CXCA018A TXC024DTUD1A040A9301A 14.5" 4CXCA024A TXC030D TDD1A060A9361A 14.5" 4CXCA024A TXC030DTUD1A060A9301A 14.5" 4TXCA018A TXC035D 4TXCA018A TXC035DTUD1A060A9241A 14.5" 4TXCA024A CCBA18A CUBA18A 4TXCA024ACCBA24ACUBA24ACCBA30ACUBA30ACCBA36ACUBA36ATUD060C937K 17.5" 2CXCB025A TXC025C 2CXAB025A TDD060C937F 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025CTUD080C924K 17.5" 2CXCB031A TXC031C 2CXAB031A TDD080C936F 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031CTUD080C936K 17.5" 2CXCB036A TXC036C 2CXAB036A TDD080C945F 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036CTUD080C948K 17.5" 2CXCB042A TXC042C 2CXAB042A TXA025C TDD100C945F 17.5" 2CXCB042A TXC042C 2CXAB042A TXA042CTUD100C936K 17.5" 2CXCB048A TXC048C 2CXAB048A TXA031C TDD1B060A9361A 17.5" 2CXCB048A TXC048C 2CXAB048A TXA048CTUD100C945K 17.5" 2TXCB025A TXC025D TXA036C TDD1B080A9361A 17.5" 2TXCB025A TXC025DTUD1B060A9361A 17.5" 2TXCB031A TXC031D TXA042C TDD1B080A9451A 17.5" 2TXCB031A TXC031DTUD1B080A9241A 17.5" 2TXCB036A TXC036D TXA048C TDD1B100A9451A 17.5" 2TXCB036A TXC036DTUD1B080A9361A 17.5" 2TXCB042A TXC031E 2TXCB042A TXC031ETUD1B080A9481A 17.5" 2TXCB048A TXC036E 2TXCB048A TXC036ETUD1B100A9361A 17.5" 4CXCB025A TXC031S 4CXCB025A TXC031STUD1B100A9451A 17.5" 4CXCB031A TXC036S 4CXCB031A TXC036S4CXCB036A RXC025S 4CXCB036A RXC025S4CXCB042A RXC031S 4CXCB042A RXC031S4CXCB048A RXC036S 4CXCB048A RXC036S4TXCB025A CUBB24A 4TXCB025A4TXCB031A CCBB30A CUBB30A 4TXCB031A4TXCB036A CCBB36A CUBB36A 4TXCB036A4TXCB042A CCBA42A CUBB42A 4TXCB042A4TXCB048A CCBA48A CUBB48A 4TXCB048ATUD080C960K 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDD100C948F 21" 2CXCC037A TXC037C 2CXAC037A TXA037CTUD100C948K 21" 2CXCC043A TXC043C 2CXAC043A TXA043C TDD100C954F 21" 2CXCC043A TXC043C 2CXAC043A TXA043CTUD100C960K 21" 2CXCC049A TXC049C 2CXAC049A TXA049C TDD120C954F 21" 2CXCC049A TXC049C 2CXAC049A TXA049CTUD120C954K 21" 2CXCC060A TXC060C 2CXAC060A TXA050C TDD1C100A9481A 21" 2CXCC060A TXC060C 2CXAC060A TXA050CTUD1C080A9601A 2TXCC037A TXC037E TDD1C100A9541A 21" 2TXCC037A TXC037ETUD1C100A9481A 2TXCC043A TXC054E TDD1C120A9541A 21" 2TXCC043A TXC054ETUD1C100A9601A 2TXCC049A TXC037S 2TXCC049A TXC037STUD1C120A9541A 2TXCC054A TXC054S 2TXCC054A TXC054S2TXCC060A RXC037S 2TXCC060A RXC037S4CXCC037A RXC054S 4CXCC037A RXC054S4CXCC043A CUBC36A 4CXCC043A4CXCC049A CUBC42A 4CXCC049A4CXCC060A CCBC48A CUBC48A 4CXCC060A4TXCC037A CCBC60A CUBC60A 4TXCC037A4TXCC043A4TXCC043A4TXCC049A4TXCC049A4TXCC054A4TXCC054A4TXCC060A4TXCC060ATUD120C960K 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDD120C960F 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060CTUD140C960K 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C TDD140C960F 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061CTUD1D100A9721A 2TXCD050A TXC065S1 TDD1D120A9601A 24.5" 2TXCD050A TXC065S1TUD1D120A9601A 2TXCD061A RXC061S TDD1D140A9601A 24.5" 2TXCD061A RXC061STUD1D140A9601A 2TXCD065A RXC065S1 2TXCD065A RXC065S14CXCD050A CUBD48A 4CXCD050A4CXCD061A CCBD60A CUBD60A 4CXCD061A4TXCD050A4TXCD050A4TXCD061A4TXCD061A4TXCD065A4TXCD065ANOTE: For reference only on Flush Fit Applications1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.FUR-33 Effective 1/1/06


Furnace/CoilsMatrixXB 80 & CoilsFurnace Cabinet Matching Matching Furnace Cabinet Matching MatchingModel Width Cased Coils Uncased Coils Model Width Cased Coils Uncased CoilsTUE040A924L 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018C TDE060A936M 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018CTUE060A936L 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024C 2CXCA024A TXC024C 2CXAA024A TXA024C2TXCA018A TXC030C TXA030C 2TXCA018A TXC030C TXA030C2TXCA024A TXC035C TXA035C 2TXCA024A TXC035C TXA035C4CXCA018A TXC024D 4CXCA018A TXC024D4CXCA024A TXC030D 4CXCA024A TXC030D4TXCA018A TXC035D 4TXCA018A TXC035D4TXCA024A CCBA18A CUBA18A 4TXCA024ACCBA24ACUBA24ACCBA30ACUBA30ACCBA36ACUBA36ATUE060A937L 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C TDE060A937M 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025CTUE080A936L 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C TDE080A945M 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031CTUE080A948L 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036C TDE100A945M 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036CTUE100A936L 17.5" 2CXCB042A TXC042C 2CXAB042A TXA042C 2CXCB042A TXC042C 2CXAB042A TXA042C2CXCB048A TXC048C 2CXAB048A TXA048C 2CXCB048A TXC048C 2CXAB048A TXA048C2TXCB025A TXC025D 2TXCB025A TXC025D2TXCB031A TXC031D 2TXCB031A TXC031D2TXCB036A TXC036D 2TXCB036A TXC036D2TXCB042A TXC031E 2TXCB042A TXC031E2TXCB048A TXC036E 2TXCB048A TXC036E4CXCB025A TXC031S 4CXCB025A TXC031S4CXCB031A TXC036S 4CXCB031A TXC036S4CXCB036A RXC025S 4CXCB036A RXC025S4CXCB042A RXC031S 4CXCB042A RXC031S4CXCB048A RXC036S 4CXCB048A RXC036S4TXCB025A CUBB24A 4TXCB025A4TXCB031A CCBB30A CUBB30A 4TXCB031A4TXCB036A CCBB36A CUBB36A 4TXCB036A4TXCB042A CCBA42A CUBB42A 4TXCB042A4TXCB048A CCBA48A CUBB48A 4TXCB048ATUE100A948L 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDE100A960M 21" 2CXCC037A TXC037C 2CXAC037A TXA037CTUE100A960L 21" 2CXCC043A TXC043C 2CXAC043A TXA043C 2CXCC043A TXC043C 2CXAC043A TXA043C2CXCC049A TXC049C 2CXAC049A TXA049C 2CXCC049A TXC049C 2CXAC049A TXA049C2CXCC060A TXC060C 2CXAC060A TXA050C 2CXCC060A TXC060C 2CXCC060A TXC050C2TXCC037A TXC037E 2TXCC037A TXC037E2TXCC043A TXC054E 2TXCC043A TXC054E2TXCC049A TXC037S 2TXCC049A TXC037S2TXCC054A TXC054S 2TXCC054A TXC054S2TXCC060A RXC037S 2TXCC060A RXC037S4CXCC037A RXC054S4CXCC037A RXC054S4CXCC043A CUBC36A 4CXCC043A4CXCC049A CUBC42A 4CXCC049A4CXCC060A CCBC48A CUBC48A 4CXCC060A4TXCC037A CCBC60A CUBC60A 4TXCC037A4TXCC043A4TXCC043A4TXCC049A4TXCC049A4TXCC054A4TXCC054A4TXCC060A4TXCC060ATUE120A960L 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDE120A960M 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060CTUE140A960L 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C 2CXCD061A TXC061C 2CXAD061A TXA061C2TXCD050A TXC065S1 2TXCD050A TXC065S12TXCD061A RXC061S 2TXCD061A RXC061S2TXCD065A RXC065S1 2TXCD065A RXC065S14CXCD050A CUBD48A 4CXCD050A4CXCD061A CCBD60A CUBD60A 4CXCD061A4TXCD050A4TXCD050A4TXCD061A4TXCD061A4TXCD065A4TXCD065ANOTE: For reference only on Flush Fit Applications1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).Effective 1/1/06FUR-34For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


TRANE “Cle<strong>an</strong>Effects ”Air Cle<strong>an</strong>er <strong>an</strong>d Upgrade KitsTable IDAQ-1-A – Air H<strong>an</strong>dler – 24 Volt TRANE Cle<strong>an</strong>Effects Whole House AirCle<strong>an</strong>erTRANEUncratedModel Airflow Cle<strong>an</strong>Effects Dimensions(in.) ShippingNumber R<strong>an</strong>ge Air H<strong>an</strong>dler Width H x W x D WeightTFD215ALAH000A 300-1200 21 1 /2 inch 7 1 /2 x 21 1 /2 x 21 42TFD235ALAH000A 350-1600 23 1 /2 inch 7 1 /2 x 23 1 /2 x 21 44TFD260ALAH000A 400-2000 26 inch 7 1 /2 x 26 x 21 46TRANE Cle<strong>an</strong>EffectsAir Cle<strong>an</strong>er:• TRANE Cle<strong>an</strong>Effects removes up to99.98% of allergens from the filtered air• Removes particles down to .3 microns insize• Outperforms HEPA, <strong>an</strong>d up to 100 timesmore effective th<strong>an</strong> a st<strong>an</strong>dard 1" filter• Constructed of heavy 18 gage metal toprotect the filter <strong>an</strong>d internal electronics• Power door provides easy access tointernal components <strong>an</strong>d features a filterstatus display as well as safety interlocksthat automatically shut down the powerwhen the door is opened for mainten<strong>an</strong>ce orcle<strong>an</strong>ing• Designed for flush fit on both sides <strong>an</strong>d rearof equipment cabinet• No tr<strong>an</strong>sitions required on TRANECle<strong>an</strong>Effects applications• Gaskets included with the air cle<strong>an</strong>er• 24 Volt input power• 10 year electronics warr<strong>an</strong>ty• 5 year parts warr<strong>an</strong>tyTRANE Cle<strong>an</strong>EffectsUpgrade Kits:• Fits <strong>an</strong>y “Perfect Fit” Air Cle<strong>an</strong>ercabinet.• Easily convert Perfect Fit, TFP, TFM orTFE product to TRANE Cle<strong>an</strong>Effects AirCle<strong>an</strong>er• 24 Volt input power• 10 year electronics warr<strong>an</strong>ty.• 5 year parts warr<strong>an</strong>ty.Table IDAQ-1-B – Upflow / Side Return Furnace – 24 Volt TRANE Cle<strong>an</strong>EffectsTRANEUncratedModel Airflow Cle<strong>an</strong>Effects Dimensions(in.) ShippingNumber R<strong>an</strong>ge Air H<strong>an</strong>dler Width H x W x D WeightTFD145ALFR000A 300-1200 14 1 /2 inch1 7 1 /2 x 14 1 /2 x 27 39TFD175ALFR000A 300-1600 17 1 /2 inch1 7 1 /2 x 17 1 /2 x 27 43TFD210ALFR000A 300-2000 21 inch2 7 1 /2 x 21 x 27 47TFD245ALFR000A 400-2000 24 1 /2 inch2 7 1 /2 x 24 1 /2 x 27 49Table IDAQ-1-C – Downflow Furnace – 24 Volt TRANE Cle<strong>an</strong>EffectsTRANEUncratedModel Airflow Cle<strong>an</strong>Effects Dimensions(in.) ShippingNumber R<strong>an</strong>ge Air H<strong>an</strong>dler Width H x W x D WeightTFD14DALFR000A 300-1200 14 1 /2 inch 7 1 /2 x 14 1 /2 x 21 33TFD17DALFR000A 300-1600 17 1 /2 inch 7 1 /2 x 17 1 /2 x 21 37TFD21DALFR000A 300-2000 21 inch 7 1 /2 x 21 x 21 41TFD24DALFR000A 400-2000 24 1 /2 inch 7 1 /2 x 24 1 /2 x 21 45Table IDAQ-1-D– Air H<strong>an</strong>dler – TRANE Cle<strong>an</strong>Effects Upgrade KitModel Airflow Perfect Fit ShippingNumber R<strong>an</strong>ge Cabinet Width WeightTFD215ALUPGRDA 300-1200 21 1 /2 inch 38TFD235ALUPGRDA 350-1600 23 1 /2 inch 40TFD260ALUPGRDA 400-2000 26 inch 42Table IDAQ-1-E – Furnace – TRANE Cle<strong>an</strong>Effects Upgrade KitModel Airflow Perfect Fit ShippingNumber R<strong>an</strong>ge Cabinet Width WeightTFD145ALUPGRD 300-1200 14 1 /2 inch1 35TFD175ALUPGRD 300-1600 17 1 /2 inch1 39TFD210ALUPGRD 300-2000 21 inch2 43TFD245ALUPGRD 400-2000 24 1 /2 inch2 45Table IDAQ-1-F – Downflow Furnace – TRANE Cle<strong>an</strong>Effects Upgrade KitModel Airflow Perfect Fit ShippingNumber R<strong>an</strong>ge Cabinet Width WeightTFD14DALUPGRD 300-1200 14 1 /2 inch 29TFD17DALUPGRD 300-1600 17 1 /2 inch 33TFD21DALUPGRD 300-2000 21 inch 37TFD24DALUPGRD 400-2000 24 1 /2 inch 41Table IDAQ-1-G — Accessories – TRANE Cle<strong>an</strong>Effects <strong>an</strong>d Upgrade KitsModelShippingNumber Description Used With WeightBAYTRANS12024 120 to 24 Volt Tr<strong>an</strong>sformer All TFD Air Cle<strong>an</strong>ers 61 Side return no Tr<strong>an</strong>sition Required.2 Side return Tr<strong>an</strong>sition Required.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.IDAQ-1 Effective 1/1/06


“Perfect Fit” Air Cle<strong>an</strong>er• Three sizes to flush fit TWE/4TEE/4TEP 6-wayconvertible Air H<strong>an</strong>dler return.• Four sizes to flush fit bottom of <strong>Tr<strong>an</strong>e</strong> furnaces.• TFP175, TFM175, TFE175 (17 1 / 2") bottomreturn model c<strong>an</strong> be used for a “Perfect Fit”side return on all furnace models.• Air Cle<strong>an</strong>ers designed for flush fit on both sides<strong>an</strong>d rear of equipment cabinet.• All service <strong>an</strong>d access is from the front of the aircle<strong>an</strong>er.• Cabinet case versatility provides three levels ofair quality.• All Electronic Air Cle<strong>an</strong>ers are shipped with a 1"washable metal pre-filter.• “Air-Tite” Door construction eliminatesair leaks, improves air quality <strong>an</strong>d keepsoperating costs low.• Gaskets included with the air cle<strong>an</strong>er.• Built-In Air Sensor Switch senses when airflows through the power assembly on <strong>an</strong>doff automatically;No “Power On” relay required.• Air Cle<strong>an</strong>er furnace models come with a120 volt power supply.• Air Cle<strong>an</strong>er Air H<strong>an</strong>dler models come with a240 volt power supply or 120 volt powersupply.Table IDAQ-2-A – Air H<strong>an</strong>dler “Perfect Fit” Dual Filtration Electronic Air Cle<strong>an</strong>er System With One (1) Inch Pre-Filter(120 Volt or 240 volt)UncratedModel Airflow Perfect Fit Dimensions(in.) Shipping ReturnNumber R<strong>an</strong>ge Voltage Air H<strong>an</strong>dler Width H x W x D Weight Air Opening3TFE215A9AH3 300-1400 120 21 1 /2 inch 7 1 /2 x 21 1 /2 x 21 45 18 7 /8 x18 7 /8TFE235A9AH3 300-1800 120 23 1 /2 inch 7 1 /2 x 23 1 /2 x 21 49 20 7 /8 x18 7 /8TFE260A9AH3 400-2100 120 26 inch 7 1 /2 x 26 x 21 53 23 7 /8 x18 7 /8TFE215A1AH3 300-1400 240 21 1 /2 inch 7 1 /2 x 21 1 /2 x 21 45 18 7 /8 x18 7 /8TFE235A1AH3 300-1800 240 23 1 /2 inch 7 1 /2 x 23 1 /2 x 21 49 20 7 /8 x18 7 /8TFE260A1AH3 400-2100 240 26 inch 7 1 /2 x 26 x 21 53 23 7 /8 x18 7 /8Table IDAQ-2-B – Furnace “Perfect Fit” Dual Filtration Electronic Air Cle<strong>an</strong>er System With One (1) Inch Pre-Filter (120 Volt)UncratedModel Airflow Perfect Fit Dimensions(in.) Shipping ReturnNumber R<strong>an</strong>ge Voltage Air H<strong>an</strong>dler Width H x W x D Weight Air Opening3TFE145A9FR3 300-1200 120 14 1 /2 inch1 7 1 /2 x14 1 /2 x 27 44 11 7 /8 x24 13 /16TFE175A9FR3 300-1500 120 17 1 /2 inch1 7 1 /2 x 17 1 /2 x 27 48 14 7 /8 x24 13 /16TFE210A9FR3 300-2000 120 21 inch2 7 1 /2 x 21 x 27 54 18 3 /8 x24 13 /16TFE245A9FR3 400-2200 120 24 1 /2 inch2 7 1 /2 x 24 1 /2 x 27 60 21 7 /8 x24 13 /16Table IDAQ-2-C — Accessories: 1" Perm<strong>an</strong>ent - Washable Filter (Ordered through Parts)Replacement Previous EnclosurePart Number Model Number Description Used WithFLR03831 BAYFTFR14W1A 1" PERMANENT - Washable 14-1/2FLR03832 BAYFTFR17W1A 1" PERMANENT - Washable 17-1/2FLR03833 BAYFTFR21W1A 1" PERMANENT - Washable 21FLR03834 BAYFTFR24W1A 1" PERMANENT - Washable 24-1/2FLR03835 BAYFTAH21W1A 1" PERMANENT - Washable 21-1/2FLR03836 BAYFTAH23W1A 1" PERMANENT - Washable 23-1/2FLR03837 BAYFTAH26W1A 1" PERMANENT - Washable 261 Side return no Tr<strong>an</strong>sition Required.2 Side return Tr<strong>an</strong>sition Required.3 Actual opening does not include fl<strong>an</strong>ge.Effective 1/1/06IDAQ-2For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


“Perfect Fit” Air Cle<strong>an</strong>er• Three sizes to flush fit TWE/4TEE/4TEP 6-wayconvertible Air H<strong>an</strong>dler return.• Four sizes to flush fit bottom of <strong>Tr<strong>an</strong>e</strong> furnaces.• Air Cle<strong>an</strong>ers designed for flush fit on both sides<strong>an</strong>d rear of equipment cabinet.• All service <strong>an</strong>d access is from the front of the aircle<strong>an</strong>er.• “Air-Tite” Door construction eliminatesair leaks, improves air quality <strong>an</strong>d keepsoperating costs low.• Gaskets included with the air cle<strong>an</strong>er.Table IDAQ-3-A– Air H<strong>an</strong>dler “Perfect Fit” High Efficiency Air Cle<strong>an</strong>er With Five (5) Inch Exp<strong>an</strong>dable Media FilterUncratedModel Airflow Perfect Fit Dimensions(in.) Shipping ReturnNumber R<strong>an</strong>ge Air H<strong>an</strong>dler Width H x W x D Weight Air Opening3TFM215B0AH0 300-1400 21 1 /2 inch 7 1 /2 x 21 1 /2 x 21 22 18 7 /8 x18 7 /8TFM235B0AH0 300-1700 23 1 /2 inch 7 1 /2 x 23 1 /2 x 21 24 20 7 /8 x18 7 /8TFM260B0AH0 400-2100 26 inch 7 1 /2 x 26 x 21 25 23 7 /8 x18 7 /8Table IDAQ-3-B – Furnace “Perfect Fit”High Efficiency Air Cle<strong>an</strong>er With Five (5) Inch Exp<strong>an</strong>dable Media FilterUncratedModel Airflow Perfect Fit Dimensions(in.) Shipping ReturnNumber R<strong>an</strong>ge Air H<strong>an</strong>dler Width H x W x D Weight Air Opening3TFM145B0FR0 300-1200 14 1 /2 inch1 7 1 /2 x14 1 /2 x 27 18 11 7 /8 x24 13 /16TFM175B0FR0 300-1500 17 1 /2 inch1 7 1 /2 x 17 1 /2 x 27 21 14 7 /8 x24 13 /16TFM210B0FR0 300-2000 21 inch2 7 1 /2 x 21 x 27 24 18 3 /8 x24 13 /16TFM245B0FR0 400-2000 24 1 /2 inch2 7 1 /2 x 24 1 /2 x 27 27 21 7 /8 x24 13 /16Table IDAQ-3-C – Downflow Furnace “Perfect Fit”High Efficiency Air Cle<strong>an</strong>er With Five (5) Inch Exp<strong>an</strong>dable Media FilterUncratedModel Airflow Perfect Fit Dimensions(in.) Shipping ReturnNumber R<strong>an</strong>ge Air H<strong>an</strong>dler Width H x W x D Weight Air Opening3TFM14DA0FR0 300-1200 14 1 /2 inch 7 1 /2 x14 1 /2 x 21 17 11 7 /8 x18 7 /8TFM17DA0FR0 300-1500 17 1 /2 inch 7 1 /2 x 17 1 /2 x 21 19 14 7 /8 x18 7 /8TFM21DA0FR0 300-2000 21 inch 7 1 /2 x 21 x 21 22 18 3 /8x18 7 /8TFM24DA0FR0 400-2000 24 1 /2 inch 7 1 /2 x 24 1 /2 x 21 24 21 7 /8 x18 7 /8Table IDAQ-3-D – Air H<strong>an</strong>dler “Perfect Fit” Medium Efficiency Air Cle<strong>an</strong>er With One (1) Inch Pleated FilterUncratedModel Airflow Perfect Fit Dimensions(in.) Shipping ReturnNumber R<strong>an</strong>ge Air H<strong>an</strong>dler Width H x W x D Weight Air Opening3TFP215A0AH1 300-1200 21 1 /2 inch 7 1 /2 x 21 1 /2 x 21 20 18 7 /8 x18 7 /8TFP235A0AH1 300-1500 23 1 /2 inch 7 1 /2 x 23 1 /2 x 21 22 20 7 /8 x18 7 /8TFP260A0AH1 400-1800 26 inch 7 1 /2 x 26 x 21 24 23 7 /8 x18 7 /8Table IDAQ-3-E – Furnace “Perfect Fit” Medium Efficiency Air Cle<strong>an</strong>er With One (1) Inch Pleated FilterUncratedModel Airflow Perfect Fit Dimensions(in.) Shipping ReturnNumber R<strong>an</strong>ge Air H<strong>an</strong>dler Width H x W x D Weight Air Opening3TFP145A0FR1 300-1200 14 1 /2 inch1 7 1 /2 x14 1 /2 x 27 17 11 7 /8 x24 13 /16TFP175A0FR1 300-1500 17 1 /2 inch1 7 1 /2 x 17 1 /2 x 27 19 14 7 /8 x24 13 /16TFP210A0FR1 400-1800 21 inch2 7 1 /2 x 21 x 27 22 18 3 /8 x24 13 /16TFP245A0FR1 400-2000 24 1 /2 inch2 7 1 /2 x 24 1 /2 x 27 25 21 7 /8 x24 13 /161 Side return no Tr<strong>an</strong>sition Required.2 Side return Tr<strong>an</strong>sition Required.3 Actual opening does not include fl<strong>an</strong>ge.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.IDAQ-3 Effective 1/1/06


“Perfect Fit” Filter AccessoriesTable IDAQ-4-A — Furnace Enclosure FiltersModel Enclosure ShippingNumber Description Qty Used with WeightBAYFTFR14P4 1" Pleated Filter 4 / Box 14 1 /2 3BAYFTFR17P4 1" Pleated Filter 4 / Box 17 1 /2 3BAYFTFR21P4 1" Pleated Filter 4 / Box 21 3BAYFTFR24P4 1" Pleated Filter 4 / Box 24 1 /2 3BAYFTFR14M2 5" Media Filter 2 / Box 14 1 /2 5BAYFTFR17M2 5" Media Filter 2 / Box 17 1 /2 5BAYFTFR21M2 5" Media Filter 2 / Box 21 5BAYFTFR24M2 5" Media Filter 2 / Box 24 1 /2 6BAYFTFREXM2 Exp<strong>an</strong>dable 5" Cartridge Media Filter 2 / Box 14 1 /2-24 1 /2 5Table IDAQ-4-B — Air H<strong>an</strong>dler Enclosure FiltersModel Enclosure ShippingNumber Description Qty Used with WeightBAYFTAH21P4 1" Pleated Filter 4 / Box 21 1 /2 3BAYFTAH23P4 1" Pleated Filter 4 / Box 23 1 /2 3BAYFTAH26P4 1" Pleated Filter 4 / Box 26 3BAYFTAH21M2 5" Media Filter 2 / Box 21 1 /2 5BAYFTAH23M2 5" Media Filter 2 / Box 23 1 /2 5BAYFTAH26M2 5" Media Filter 2 / Box 26 6BAYFTAHEXM2 Exp<strong>an</strong>dable 5" Cartridge Media Filter 2 / Box 21 1 /2-26 5Table IDAQ-4-C — Downflow Cartridge MediaModel Enclosure ShippingNumber Description Qty Used with WeightBAYFTDN14M2 5" Downflow Media Filter 2/ Box 14 D 5BAYFTDN17M2 5" Downflow Media Filter 2/ Box 17 D 5BAYFTDN21M2 5" Downflow Media Filter 2/ Box 21 D 5BAYFTDN24M2 5" Downflow Media Filter 2/ Box 24 D 5Table IDAQ-4-D — Furnace FramesModel Enclosure ShippingNumber Description Qty Used with WeightBAYFRAME1451 Exp<strong>an</strong>dable Media Filter 1/ Box 14 1 /2 5BAYFRAME1751 Exp<strong>an</strong>dable Media Filter 1/ Box 17 1 /2 5BAYFRAME2101 Exp<strong>an</strong>dable Media Filter 1/ Box 21 5BAYFRAME2451 Exp<strong>an</strong>dable Media Filter 1/ Box 24 1 /2 5Table IDAQ-4-E — Air H<strong>an</strong>dler FramesModel Enclosure ShippingNumber Description Qty Used with WeightBAYFRAME2151 Exp<strong>an</strong>dable Media Frame 1/ Box 21 5BAYFRAME2351 Exp<strong>an</strong>dable Media Frame 1/ Box 23 1 /2 5BAYFRAME2601 Exp<strong>an</strong>dable Media Frame 1/ Box 26 51 Includes one filter.Effective 1/1/06IDAQ-4For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


“Perfect Fit”Table IDAQ-5-A — Air H<strong>an</strong>dler FiltersAIR HANDLER MODEL NUMBER1" Pleated Filter 5" Media Filter Electronic Filter Cle<strong>an</strong>Effects A BTFP215A0AH0 TFM215A0AH0 TFE215A1AH0, A9AH0 TFD215ALAH000A 21-1/2 18-7/8TFP235A0AH0 TFM235A0AH0 TFE235A1AH0, A9AH0 TFD235ALAH000A 23-1/2 20-7/8TFP260A0AH0 TFM260A0AH0 TFE260A1AH0, A9AH0 TFD260ALAH000A 26 23-7/8Side ViewTopofCabinetFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.IDAQ-5 Effective 1/1/06


“Perfect Fit”Table IDAQ-6-A — Upflow Furnace FiltersFURNACE MODEL NUMBER1" Pleated Filter 5" Media Filter Electronic Filter Cle<strong>an</strong>Effects A BTFP145A0FR0 TFM145A0FR0 TFE145A9FR0 TFD145ALFR000A 14-1/2 11-7/8TFP175A0FR0 TFM175A0FR0 TFE175A9FR0 TFD175ALFR000A 17-1/2 14-7/8TFP210A0FR0 TFM210A0FR0 TFE210A9FR0 TFD210ALFR000A 21 18-3/8TFP245A0FR0 TFM245A0FR0 TFE245A9FR0 TFD245ALFR000A 24-1/2 21-7/8Table IDAQ-6-B — Downflow Furnace FiltersFURNACE MODEL NUMBER5" Media Filter ifD Filter A BTFM14DA0FR0 TFD14DALFR000A 14-1/2 11-7/8TFM17DA0FR0 TFD17DALFR000A 17-1/2 14-7/8TFM21DA0FR0 TFD21DALFR000A 21 18-3/8TFM24DA0FR0 TFD24DALFR000A 24-1/2 21-7/8OUTLINE DRAWINGDOWNFLOW FURNACE MODELSOUTLINE DRAWING UPFLOW FURNACE MODELSSide ViewSide ViewTopofCabinetTopofCabinetEffective 1/1/06IDAQ-6For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


HumidifiersF<strong>an</strong> Powered <strong>an</strong>d BypassTHUMD500ATHUMD500A• Flow Through F<strong>an</strong> Powered Humidifier• High Perform<strong>an</strong>ce Humidifier Delivers up to18 Gallons per Day• Automatic Humidifier Control with O.D.Sensor for up to 50% more Humidity• Front Cover Access for easy replacement ofhumidifier pad.• Aluminum Humidifier Pad Treated withCeramic Clay for Enh<strong>an</strong>ced Pad Perform<strong>an</strong>ce• Reliable Brass Solenoid Valve w/StainlessSteel Valve Seat• UV Resist<strong>an</strong>t Cabinet <strong>an</strong>d Scale ControlInsert• Saddle Valve• Polyslate Gray Housing matches FurnaceCabinet Color• Decorative nameplate• 120V Power Line CordTHUMD200A, 300ATHUMD200,300A• THUMD300A Bypass delivers up to 17Gallons per day• THUMD200A delivers up to 12 Gallons perday.• THUMD300A Automatic Humidifier Control<strong>an</strong>d O.D. Sensor for up to 50% moreHumidity• THUMD200A M<strong>an</strong>ual Humidifier Control• UV Resist<strong>an</strong>t Cabinet <strong>an</strong>d Scale ControlInsert• Front Cover Access for easy replacement ofhumidifier pad.• Aluminum Humidifier Pad Treated withCeramic Clay for Enh<strong>an</strong>ced Pad Perform<strong>an</strong>ce• Reliable Brass Solenoid Valve w/StainlessSteel Valve Seat• Field Convertible Duct Connection, Left orRight Side• Built in Summer / Winter Damper• UV Resist<strong>an</strong>t Cabinet <strong>an</strong>d Scale ControlInsert• Saddle Valve• Polyslate Gray Housing matches FurnaceCabinet Color• Decorative nameplate• 120 V Primary• 24V Secondary, 10VATable IDAQ-7-A — Specifications: Humidifier with HumidistatModel Mfg. ShippingNumber Description Used With Pl<strong>an</strong>t WeightTHUMD500APA00A14 F<strong>an</strong> Powered Humidifer All Furnace Models TY 1THUMD300ABA00A2 Large Bypass Humidifier All Furnace Models TY 1THUMD200ABM00A3 Small Bypass Humidifier All Furnace Models TY 11 Includes Automatic Humidifier Control (Duct Mount Only)2 Includes Automatic Humidifier Control (Duct Mount Only) <strong>an</strong>d 120/24V tr<strong>an</strong>sformer3 Includes M<strong>an</strong>ual Humidifier Control <strong>an</strong>d 120/24V tr<strong>an</strong>sformer4 Not applicable for horizontal installationsTable IDAQ-7-B — AccessoriesModel Mfg. ShippingNumber Description Used With Pl<strong>an</strong>t WeightBAYPAD02A1310A Large Humidifier Pad 13”x10” THUMD500,300A TY 1BAYPAD01A1010A Small Humidifier Pad 9-7/8”x9-5/8” THUMD200A TY 1TCONTH01AAUTOA Automatic Humidifier Control THUMD200A TY 1BAYRLY10ASENSA Current Sensing Relay All TY 1BAYPLT01AMHCOA Adapter Plate (Duct Mount) M<strong>an</strong>ual Humidifier Control TY 1For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.IDAQ-7 Effective 1/1/06


HumidifiersF<strong>an</strong> Powered <strong>an</strong>d BypassTHUMD500PA00A FAN POWERED HUMIDIFIERTHUMD300AB00A LARGE BYPASS HUMIDIFIERTHUMD200AB00A SMALL BYPASS HUMIDIFIEREffective 1/1/06IDAQ-8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


HumidifiersF<strong>an</strong> Powered <strong>an</strong>d BypassMANUAL HUMIDIFIER CONTROL(SHIP WITH THUMD200AB00A)TCONTH01AAUTOA AUTOMATIC HUMIDIFIER CONTROLSUGGESTED BYPASS HUMIDFIER LOCATIONSRETURN AIROPTIONAL FLUENOT ALL MODELSSUPPLY AIRFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.IDAQ-9 Effective 1/1/06


FreshEffects Energy RecoveryVentilator (ERV)• FreshEffects ERV technology for allseasons <strong>an</strong>d climates• Static plate energy tr<strong>an</strong>sfer core for efficienttr<strong>an</strong>sfer of heat <strong>an</strong>d moisture• Passive defrost - condensate drain notrequired• Bal<strong>an</strong>cing dampers not required• Multi position mounting• Percent Timer (PT) control included withERV for simple, automatic operation• Optional push button control for use with PTcontrol• Cam action door latches for quick serviceaccess• Heavy gauge, powder painted steel cabinet• Perm<strong>an</strong>ently lubricated motor bearings• 6” <strong>an</strong>d 8” double collar duct connections forTERVR100 <strong>an</strong>d 200• 8” round compatible duct connection forTERVR300• Closed cell foam gasketing for insulationintegrity• 1” duct board insulation withcle<strong>an</strong>able foil face• May be installed in conditioned <strong>an</strong>dunconditioned spaces• Cabinet / Door color: <strong>Tr<strong>an</strong>e</strong> Polyslate Gray /Tarpaulin Gray• 5 year limited warr<strong>an</strong>ty on parts• 10 year limited warr<strong>an</strong>ty on energytr<strong>an</strong>sfer core• Optional extended warr<strong>an</strong>tyTable IDAQ-10-A — Specifications: ERVNominal UncratedModel Airflow Power Dimensions (In.) ShippingNumber (CFM) Supply H W D WeightTERVR100A9P00A1 130 120/1/60 20-1/8 28-3/4 13 58TERVR200A9P00A1 200 120/1/60 20-1/8 28-3/4 23-7/8 80TERVR300A9P00A12 300 120/1/60 20-1/8 28-3/4 23-7/8 881 Percent Timer Control included with the ERV2 Available in April 2006Table IDAQ-10-B — Specifications: ERVModel Apparent Sensible Sensible Recovery Latent TotalNumber Effectiveness(32°F) Effectiveness(32°F) Recovery (32°F) Recovery (32°F)TERVR100A9P00A 80% @ 120 cfm 84% @ 120 cfm 73% @ 251 cfm 51% @ 63 cfmTERVR200A9P00A 72% @ 120 cfm 77% @ 120 cfm 64% @ 251 cfm 59% @ 63 cfmTERVR300A9P00A2 44% @ 120 cfm 63% @ 120 cfm 40% @ 251 cfm 31% @ 252 cfm2 Available in April 2006Table IDAQ-10-C — Optional AccessoriesModelShippingNumber Description Used With WeightTCONTV10APBC0A Point of Use Push Button Control ERV models 100, 200, 300 1BAYFLT10A1010A Filters - 2 per pack ERV models 100 1BAYFLT20A1020A Filters - 2 per pack ERV models 200, 300 1BAYWHT10AVENTA3 6 inch White Vinyl Ventilation Hood ERV models 100, 200 1BAYBRN10AVENTA3 6 inch Brown Vinyl Ventilation Hood ERV models 100, 200 1BAYGLV10AVENTA3 8 inch Galvenized Ventilation Hood ERV models 300 23 Qty 1Effective 1/1/06IDAQ-10For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package CoolingConvertible 1½ through 5 Tons• Architecturally integrated louvers <strong>an</strong>d cornerguards deliver durable protection, extrasafety, <strong>an</strong>d great looks.• Weather Beater Top contoured for greatappear<strong>an</strong>ce <strong>an</strong>d reinforced for strength.• Ultra quiet operation provides best-in-classperform<strong>an</strong>ce with barely noticeable soundlevels.• Appli<strong>an</strong>ce grade finish of durable powderpaint baked on both sides of the p<strong>an</strong>els.• Exclusive Climatuff® high efficiencycompressor with internal overload protection.• Aerospace ducted outdoor f<strong>an</strong> with a highefficiency motor for quiet <strong>an</strong>d reliableoperation.• Composite Vortica® blower provides betterairflow <strong>an</strong>d less sound while using lessenergy.• Spine Fin outdoor coil for long lastingperform<strong>an</strong>ce <strong>an</strong>d durability.• Right side electrical service for high <strong>an</strong>d lowvoltage lines.• Rugged steel basep<strong>an</strong> features deep drawnduct connections <strong>an</strong>d emergency drains.• Steeply sloped composite drainp<strong>an</strong> willempty fast <strong>an</strong>d never rust.Table PC-1-A — 4TCX- XL13c - Convertible Package Cooling - R-410ACabinetModel Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER Weight MCA Fuse Rating H x W x L4TCX – 208/230/1/604TCX3018A1000A 18,800 13.65/11.20 444 10.1 15 69 36 x 51 x 434TCX3024A1000A 24,800 13.30/11.00 444 13.6 20 72 36 x 51 x 434TCX3030A1000A 29,800 13.15/11.65 445 21.7 35 72 36 x 51 x 434TCX3036A1000A 36,200 13.30/11.00 450 23.2 35 72 36 x 51 x 434TCX3042A1000A 43,500 13.05/11.00 523 27.9 45 72 38 x 46 x 614TCX3048A1000A 46,500 13.15/11.00 607 31.1 50 72 38 x 46 x 614TCX3060A1000A 60,500 13.40/11.05 610 43.3 60 72 40 x 46 x 614TCX – 208/230/3/604TCX3036A3000A 36,200 13.30/11.00 450 18.2 30 72 36 x 51 x 434TCX3048A3000A 46,500 13.14/11.00 607 23.6 35 72 38 x 46 x 614TCX3060A3000A 60,500 13.40/11.05 610 31.5 50 72 40 x 46 x 614TCX – 460/3/604TCX3036A4000A 36,200 13.30/11.00 450 8.7 15 72 36 x 51 x 434TCX3048A4000A 46,500 13.15/11.00 607 11.7 15 72 38 x 46 x 614TCX3060A4000A 60,500 13.40/11.00 610 19.3 25 79 40 x 46 x 61• Ships in horizontal configuration <strong>an</strong>d convertsquickly for downflow.• Complete set of customized electric heatersdesigned for all models. Features a polarizedplug for easy installation.• Optional filter rack kits fit inside the unit.Available for 1" or 2" media.• Non-bleed exp<strong>an</strong>sion valves on indoor <strong>an</strong>doutdoor coils.• Direct drive 2 <strong>an</strong>d 3 speed indoor blowermotors.• Pressure taps easily accessed <strong>an</strong>d protectedinside compressor compartment.• Easy access liquid line tap inside compressorcompartment.• St<strong>an</strong>dard operation to 55°F as m<strong>an</strong>ufactured.• Low ambient cooling to 0°F with kit.• UL approved <strong>an</strong>d listed.• 20 year heat exch<strong>an</strong>ger, 10 year compressor,10 year outdoor coil, <strong>an</strong>d 5 years otherparts limited warr<strong>an</strong>ty.(<strong>Residential</strong> Use Only)• Optional extended warr<strong>an</strong>ty.For information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-1 Effective 1/1/06


Package CoolingConvertible 1½ through 5 Tons4TCX3018A through 4TCX3036AFor information on Roof Curbs <strong>an</strong>dRoof Curb Adaptors, please refer tothe Accessories/Information Tab.Effective 1/1/06PC-2For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package CoolingConvertible 1½ through 5 Tons4TCX3018A through 4TCX3036AFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-3 Effective 1/1/06


Package CoolingConvertible 1½ through 5 Tons4TCX3042A through 4TCX3060AFor information on Roof Curbs <strong>an</strong>dRoof Curb Adaptors, please refer tothe Accessories/Information Tab.Effective 1/1/06PC-4For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package CoolingConvertible 1½ through 5 Tons4TCX3042A through 4TCX3060AFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-5 Effective 1/1/06


Package CoolingConvertible 1½ through 5 Tons• All steel louvers <strong>an</strong>d cabinet for rugged, longlasting protection.• Weather Beater Top contoured for greatappear<strong>an</strong>ce <strong>an</strong>d reinforced for strength.• Quiet operation delivers great in-homecomfort with minimal sound.• Appli<strong>an</strong>ce grade finish of durable powderpaint baked on both sides of the p<strong>an</strong>els.• Exclusive Climatuff® high efficiencycompressor with internal overload protection.• High efficiency outdoor f<strong>an</strong> motor for quiet<strong>an</strong>d reliable operation.• Composite Vortica® blower provides betterairflow <strong>an</strong>d less sound while using lessenergy.• Spine Fin outdoor coil for long lastingperform<strong>an</strong>ce <strong>an</strong>d durability.• Right side electrical service for high <strong>an</strong>d lowvoltage lines.• Rugged steel basep<strong>an</strong> features deep drawnduct connections <strong>an</strong>d emergency drains.• Steeply sloped composite drainp<strong>an</strong> willempty fast <strong>an</strong>d never rust.• Ships in horizontal configuration <strong>an</strong>dconverts quickly for downflow.• Complete set of customized electric heatersdesigned for all models. Features a polarizedplug for easy installation.• Optional filter rack kits fit inside the unit.Available for 1" or 2" media.• Non-bleed exp<strong>an</strong>sion valves on indoor <strong>an</strong>doutdoor coils.• Direct drive 2 <strong>an</strong>d 3 speed indoor blowermotors.• Pressure taps easily accessed <strong>an</strong>d protectedinside compressor compartment.• Easy access liquid line tap inside compressorcompartment.• St<strong>an</strong>dard operation to 55°F as m<strong>an</strong>ufactured.• Low ambient cooling to 0°F with kit.• UL approved <strong>an</strong>d listed.• 5 year compressor <strong>an</strong>d 5 years other partslimited warr<strong>an</strong>ty. (<strong>Residential</strong> Use Only)• Optional extended warr<strong>an</strong>ty.Table PC-6-A — 4TCC–XB13c - Convertible Package Cooling - R-410ACabinetModel Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER Weight MCA Fuse Rating H x W x L4TCC – 208/230/1/604TCC3018A1000A 18,000 13.0/11.00 444 10.1 15 74 36 x 49 x 424TCC3024A1000A 23,000 13.0/11.00 444 13.6 20 76 36 x 49 x 424TCC3030A1000A 28,000 13.0/11.00 445 21.7 35 75 36 x 49 x 424TCC3036A1000A 35,000 13.0/11.00 450 23.2 35 76 36 x 49 x 424TCC3042A1000A 40,000 13.0/11.00 523 27.9 45 78 38 x 59 x 444TCC3048A1000A 46,500 13.0/11.00 607 31.1 50 80 38 x 59 x 444TCC3060A1000A 58,000 13.0/11.00 610 43.3 60 79 40 x 59 x 444TCC – 208/230/3/604TCC3036A3000A 35,000 13.0/11.00 450 18.2 30 76 36 x 49 x 424TCC3048A3000A 46,500 13.0/11.00 607 23.6 35 80 38 x 59 x 444TCC3060A3000A 58,000 13.0/11.00 610 31.5 50 79 40 x 59 x 444TCC – 460/3/604TCC3036A4000A 35,000 13.0/11.00 450 8.7 15 76 36 x 49 x 424TCC3048A4000A 46,500 13.0/11.00 607 11.7 15 80 38 x 59 x 444TCC3060A4000A 58,000 13.0/11.00 610 19.3 25 79 40 x 59 x 44For information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.Effective 1/1/06PC-6For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package CoolingConvertible 1½ through 5 Tons4TCC3018A through 4TCC3036AFor information on Roof Curbs <strong>an</strong>dRoof Curb Adaptors, please refer tothe Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-7 Effective 1/1/06


Package CoolingConvertible 1½ through 5 Tons4TCC3018A through 4TCC3036AFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.Effective 1/1/06PC-8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package CoolingConvertible 1½ through 5 Tons4TCC3042A through 4TCC3060AFor information on Roof Curbs <strong>an</strong>dRoof Curb Adaptors, please refer tothe Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-9 Effective 1/1/06


Package CoolingConvertible 1½ through 5 Tons4TCC3042A through 4TCC3060AFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.Effective 1/1/06PC-10For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package CoolingConvertible 1½ through 5 Tons4TCX3 4TCC3Table PC-11-A — Accessories 1½-5 1½-5BAYADAP050A ...... Adapter Curb (Cabinet A/B) ............................................................................................................................ 1½-3 1½-3BAYADAP051A ...... Adapter Curb (Cabinet C) ............................................................................................................................... 1½-3 1½-3BAYADAP052A ...... Adapter Curb (Cabinet A/B) ............................................................................................................................ 3½-5 3½-5BAYADAP053A ...... Adapter Curb (Cabinet C) ............................................................................................................................... 3½-5 3½-5BAYADAP054A ...... Adapter Curb (Cabinet D) ............................................................................................................................... 3½-5 3½-5BAYCCHT101A ..... Cr<strong>an</strong>kcase Heater (230V) .............................................................................................................................. 1½-2 1½-2BAYCCHT102A ..... Cr<strong>an</strong>kcase Heater (230V) .............................................................................................................................. 2½-5 2½-5BAYCCHT104A ..... Cr<strong>an</strong>kcase Heater (460V) .............................................................................................................................. 3,4,5 3,4,5BAYCOVR112A ..... 12" Duct Shourd (Covers Horizontal Ducts)0 ................................................................................................. 1½-3 1½-3BAYCOVR118A ..... 18" Duct Shourd (Covers Horizontal Ducts)0 ................................................................................................. 1½-3 1½-3BAYCURB050A ..... Flat Roof Curb (Insulated)5 ........................................................................................................................... 1½- 3 1½- 3BAYCURB051A ..... Flat Roof Curb (Insulated)6 ........................................................................................................................... 3½-5 3½-5BAYDMPR101A ..... 2-Position Motorized Damper ......................................................................................................................... 1½- 3 1½- 3BAYDMPR102A ..... 2-Position Motorized Damper ......................................................................................................................... 3½-5 3½-5BAYECON101A ..... Economizer with Barometric Relief1347 .................................................................................................... 1½- 3 1½- 3BAYECON102A ..... Economizer with Barometric Relief1347 .................................................................................................... 3½-5 3½-5BAYECON200A ..... Economizer (Horizontal)137 ........................................................................................................................ 1½- 3 1½- 3BAYECON201A ..... Economizer (Horizontal)137 ........................................................................................................................ 3½-5 3½-5BAYENTH100A ..... Enthalpy Control Kit3 ..................................................................................................................................... ✔ ✔BAYEXMK001A ..... Extreme Conditions Mounting Kit (Used on BAYCURB & BAYADAP) ............................................................. ✔ ✔BAYEXMK002A ..... Extreme Conditions Mounting Kit (Used on BAYUTIL) .................................................................................... ✔ ✔BAYEXMK003A ..... Extreme Conditions Mounting Kit (Used on Slab Mounts) ............................................................................... ✔ ✔BAYFLTR101A ....... 1-2" Filter Frame1 .......................................................................................................................................... 1½- 3 1½- 3BAYFLTR201A ....... 1-2" Filter Frame1 .......................................................................................................................................... 3½-4 3½-4BAYLIFT002BA ..... Lifting Lug Kit ................................................................................................................................................. ✔ ✔BAYLOAM011A ..... Evaporator Defrost Control Kit ........................................................................................................................ ✔ ✔BAYLOAM105A ..... Low Ambient Control Kit ................................................................................................................................. ✔ ✔BAYOSAH001A ..... M<strong>an</strong>ual Fresh Air Damper14 ........................................................................................................................ 1½-3 1½-3BAYOSAH002A ..... M<strong>an</strong>ual Fresh Air Damper14 ........................................................................................................................ 3½-5 3½-5BAYQSTK300A ..... Quick Start Kit .............................................................................................................................................. 1 Phase Only 1 Phase OnlyBAYSQRD001A ..... 16" Round Duct Adapter9 ............................................................................................................................. 1½-3 1½-3BAYSQRD002A ..... 18" Round Duct Adapter9 ............................................................................................................................. 1½-5 1½-5BAYUTIL101A ....... Roof Curb Utility Extension Kit ........................................................................................................................ 1½-3 1½-3BAYUTIL102A ....... Roof Curb Utility Extension Kit ........................................................................................................................ 3½-5 3½-51 Must use filter frame when economizer/fresh air kit is used.2 Ships knocked down.3 Dry bulb control st<strong>an</strong>dard with economizer.4 Downflow Only.5 Full perimeter curb for 4TC*3018-036A.6 Full perimeter curb for 4TC*3042-060A.7 2-Stage thermostat provides additional energy savings if simult<strong>an</strong>eous economizer <strong>an</strong>d compressor operation is expected.8 Do not use with programmable thermostats.9 It is the responsibility of the installing dealer to properly size the ductwork for each specific application.0 BAYCOVR112,118A will not cover BAYSQRD002A applicationsFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-11 Effective 1/1/06


Package CoolingConvertible 1½ through 5 TonsTable PH-12-A — Supplementary Heaters – Separate power source /power entry requiredModelShippingNumber Description Used With WeightBAYHTRV105A 3.76/5.0 kW Heater (208/240V 1PH) 4TC*3018-060A1 9BAYHTRV110A 7.50/10.0 kW Heater (208/240V 1PH) 4TC*3024-060A1 10BAYHTRV115A 11.27/15.00 kW Heater (208/240V 1PH) 4TC*3030-060A1 14BAYHTRV120A 15.00/20.0 kW Heater (208/240V 1PH) 4TC*3048-060A1 14BAYHTRV305A 3.76/5.0 kW Heater (208/240V 3PH) 4TC*3018-060A3 9BAYHTRV310A 7.50/10.0 kW Heater (208/240V 3PH) 4TC*3024-060A3 10BAYHTRV315A 11.27/15.00 kW Heater (208/240V 3PH) 4TC*3030-060A3 14BAYHTRV320A 15.0/20.0 kW Heater (208/240V 3PH) 4TC*3048-060A3 14BAYHTRV405A 3.76/5.0 kW Heater (460V 3PH) 4TC*3018-060A4 9BAYHTRV410A 7.50/10.0 kW Heater (460V 3PH) 4TC*3024-060A4 10BAYHTRV415A 11.27/15.00 kW Heater (460V 3PH) 4TC*3030-060A4 14BAYHTRV420A 15.0/20.0 kW Heater (460V 3PH) 4TC*3048-060A4 14Table PH-12-B — Single Power Entry Kit/Heater Matrix:Single Power Heater Unit ShippingEntry Kit1 Model Model WeightBAYSPEK060A BAYHTRV105A 4TC*3018-048A1 3BAYHTRV110A4TC*3024-048A1BAYSPEK061A BAYHTRV305A 4TC*3036-060A3 7BAYHTRV310A4TC*3036-048A3BAYHTRV315A4TC*3036-060A3BAYHTRV405A4TC*3036-060A4BAYHTRV410A4TC*3036-060A4BAYHTRV415A4TC*3036-060A4BAYHTRV420A4TC*3048-060A4BAYSPEK062A BAYHTRV105A 4TC*3060A1 7BAYHTRV110A4TC*3060A1BAYSPEK063A BAYHTRV115A 4TC*3030-060A1 7BAYHTRV120A4TC*3048-060A1BAYSPEK064A BAYHTRV320A 4TC*3048-060A3 61 All necessary fuses are included in kitFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.Effective 1/1/06PC-12For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


XL1400Package CoolingConvertible 2 through 5 TonsTCY — XL 1400 TCX — XL 1200Table PC-13-A — TCY – XL 1400 Convertible Package CoolingCooling Cabinet Supply/Return Supply /Return ShippingUnit Capacity Dimensions (in.) Downflow Horizontal Weight Max SoundModel No. SEER/EER* (Btuh) H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating CompressorTCY – 208-230/1/60PHASED OUTTCY042G100A 14.00/11.70 41,500 29 x 36 x 64 (C) 17 1 /2 x 10 18 9 /16 x 11 1 /16 448 26.7 40 80 R2TCY024G100B 14.00/12.00 24,000 29 x 36 x 56 (B) 17 1 /2 x 10 18 9 /16 x 11 1 /16 371 15.9 25 80 R1TCY030G100A 13.00/11.00 30,600 29 x 36 x 56 (B) 17 1 /2 x 10 18 9 /16 x 11 1 /16 382 21.4 30 80 R2TCY036G100A 14.10/12.00 36,000 29 x 36 x 64 (C) 17 1 /2 x 10 18 9 /16 x 11 1 /16 448 24.8 35 80 R2TCY048G100A 14.40/12.20 49,000 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 561 32.7 50 84 R2TCY060G100A 13.00/11.00 61,000 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 566 46.8 60 84 STable PC-13-B — TCX – XL 1200 Convertible Package CoolingCooling Cabinet Supply/Return Supply /Return ShippingUnit Capacity Dimensions (in.) Downflow Horizontal Weight Max SoundModel No. SEER/EER* (Btuh) H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating CompressorTCX – 208-230/1/60TCX024G100B 12.00/10.50 24,500 25 x 36 x 56 (A) 17 1 /2 x 10 18 9 /16 x 11 1 /16 351 14.6 20 80 R1TCX030G100A 12.05/10.90 30,600 29 x 36 x 56 (B) 17 1 /2 x 10 18 9 /16 x 11 1 /16 363 21.2 30 80 STCX036G100A 12.05/10.50 37,000 29 x 36 x 56 (B) 17 1 /2 x 10 18 9 /16 x 11 1 /16 374 24.4 40 80 STCX042G100A 12.05/10.55 43,000 29 x 36 x 56 (B) 17 1 /2 x 10 18 9 /16 x 11 1 /16 384 26.8 40 80 STCX048G100A 12.50/11.45 48,000 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 480 31.9 50 84 STCX060G100A 12.05/10.55 61,500 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 507 45.0 70 84 STCX – 208-230/3/60PHASED OUTTCX036G300A 12.05 37,000 29 x 36 x 56 (B) 17 1 /2 x 10 18 9 /16 x 11 1 /16 374 17.4 25 80 STCX042G300A 12.05 43,000 29 x 36 x 56 (B) 17 1 /2 x 10 18 9 /16 x 11 1 /16 384 19.9 30 80 STCX048G300A 12.50 48,000 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 480 24.5 35 84 STCX060G300A 12.05 61,500 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 507 30.6 45 84 STCX – 460/3/60TCX036G400A 12.05 37,000 29 x 36 x 56 (B) 17 1 /2 x 10 18 9 /16 x 11 1 /16 374 10.0 15 80 STCX048G400A 12.50 48,000 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 480 15.4 20 84 STCX060G400A 12.05 61,500 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 507 15.1 20 84 S* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = ScrollFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-13 Effective 1/1/06


Package CoolingConvertible 1½ through 5 TonsTCP — XE 1200TCC — XE 1000Table PC-14-A — TCP – XE 1200 Convertible Package CoolingCooling Cabinet Supply/Return Supply /Return ShippingUnit Capacity Dimensions (in.) Downflow Horizontal Weight Max SoundModel No. SEER/EER* (Btuh) H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating CompressorTCP – 208-230/1/60TCP024F100B 12.10/10.50 24,500 25 x 36 x 56 (A) 17 1 /2 x 10 18 9 /16 x 11 1 /16 351 14.6 20 80 R1TCP030F100A 12.00/10.90 30,000 29 x 36 x 56 (B) 17 1 /2 x 10 18 9 /16 x 11 1 /16 363 21.2 30 80 STCP036F100A 12.00/10.50 36,000 29 x 36 x 56 (B) 17 1 /2 x 10 18 9 /16 x 11 1 /16 374 24.4 40 80 STCP042F100A 12.00/11.45 42,000 29 x 36 x 56 (B) 17 1 /2 x 10 18 9 /16 x 11 1 /16 384 26.8 40 80 STCP048F100A 12.20/11.45 47,000 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 480 31.9 50 84 STCP060F100A 12.00/10.55 60,000 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 507 45 70 84 STCP – 208-230/3/60TCP036F300A 12.00 36,000 29 x 36 x 56 (B) 17 1 /2 x 10 18 9 /16 x 11 1 /16 374 17.4 25 80 SPHASED OUTTCP042F300A 12.00 42,000 29 x 36 x 56 (B) 17 1 /2 x 10 18 9 /16 x 11 1 /16 384 19.9 30 80 STCP048F300A 12.20 47,000 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 480 24.5 35 84 STCP060F300A 12.00 60,000 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 507 30.6 45 84 STCP – 460/3/60TCP036F400A 12.00 36,000 29 x 36 x 56 (B) 17 1 /2 x 10 18 9 /16 x 11 1 /16 374 10 15 80 STCP048F400A 12.20 47,000 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 480 15.4 20 84 STCP060F400A 12.00 60,000 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 507 15.1 20 84 STable PC-14-B — TCC – XE 1000 Convertible Package CoolingCooling Cabinet Supply/Return Supply /Return ShippingUnit Capacity Dimensions (in.) Downflow Horizontal Weight Max SoundModel No. SEER/EER* (Btuh) H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating CompressorTCC – 208-230/1/60TCC018F100B 10.00/9.35 18,000 25 x 36 x 55 (A) 17 1 /2 x 10 18 9 /16 x 11 1 /16 319 15.0 20 80 R1TCC024F100B 10.00/9.10 23,400 25 x 36 x 55 (A) 17 1 /2 x 10 18 9 /16 x 11 1 /16 327 17.7 25 80 R1TCC030F100B 10.00/9.10PHASED29,800 29 x 36 x 55 (B) 17 1 OUT/2 x 10 18 9 /16 x 11 1 /16 354 22.7 35 80 R1TCC042F100B 10.00/8.60 40,500 29 x 36 x 55 (B) 17 1 /2 x 10 18 9 /16 x 11 1 /16 389 31.2 50 80 R2TCC048F100B 10.00/9.25 48,000 33 x 45 x 64 (D) 20 x 14 21 1 /16 x 15 1 /16 513 37.0 55 84 R2TCC060F100B 10.00/9.20 60,000 33 x 45 x 64 (D) 20 x 14 21 1 /16 x 15 1 /16 547 43.9 70 84 R2TCC – 208-230/3/60 - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.TCC036F300B 10.00 35,400 29 x 36 x 55 (B) 17 1 /2 x 10 18 9 /16 x 11 1 /16 369 19.9 30 80 R1/2TCC042F300B 10.00 40,500 29 x 36 x 55 (B) 17 1 /2 x 10 18 9 /16 x 11 1 /16 389 22.9 35 80 R2TCC048F300B 10.00 48,000 33 x 45 x 64 (D) 20 x 14 21 1 /16 x 15 1 /16 513 27.0 40 84 R2TCC060F300B 10.00 60,000 33 x 45 x 64 (D) 20 x 14 21 1 /16 x 15 1 /16 547 31.0 45 84 R2TCC – 460/3/60 - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.TCC036F400B 10.00 35,400 29 x 36 x 55 (B) 17 1 /2 x 10 18 9 /16 x 11 1 /16 369 10.5 15 80 R1/2TCC048F400B 10.00 48,000 33 x 45 x 64 (D) 20 x 14 21 1 /16 x 15 1 /16 513 12.7 20 84 R2TCC060F400B 10.00 60,000 33 x 45 x 64 (D) 20 x 14 21 1 /16 x 15 1 /16 547 16.3 25 84 R2* Information subject to ch<strong>an</strong>ge. Please confirm with currentProduct Data/Service Facts for current factory production.Note: TCC-F models currently m<strong>an</strong>ufactured with sloped drain p<strong>an</strong>s.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = ScrollEffective 1/1/06PC-14For information on Roof Curbs <strong>an</strong>dRoof Curb Adaptors, please refer tothe Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package CoolingConvertible 1½ through 5 TonsBASUPPLY &RETURN PANELEVAPORATOR COIL &BLOWER PANELCCENTER OFGRAVITYEFEGHECONOMIZER/FILTERACCESS PANELKHORIZONTALSUPPLYOPENINGJ35 MM(1 3/8")DOWNFLOWSUPPLYOPENINGDLPMHORIZONTALRETURN OPENINGDXLXMNYY76 MM(3")29 MM(1 1/8")CONDENSATE DRAIN19 MM (3/4") FEMALE NPTDOWNFLOWRETURN OPENINGTable PC-15-A — TCY – XL 1400 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0TCY024G 56 1 /2 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 25 3 /8 17 1 /2 10 3 4 7 /16 30A, 38APHASED OUTTCY030G 56 1 /2 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 24 3 /8 17 1 /2 10 3 4 7 /16 30A, 38ATCY036G 64 36 29 1 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 19 1 /4 27 1 /2 17 1 /2 10 3 8 3 /4 30A, 38A, 33ATCY042G 64 36 29 1 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 19 1 /4 27 1 /2 17 1 /2 10 3 8 3 /4 30A, 38A, 33ATCY048G 65 1 /4 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 25 1 /4 28 1 /2 20 14 3 1 /2 8 5 /16 30A, 38A, 34ATCY060G 65 1 /4 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 25 1 /4 28 1 /2 20 14 3 1 /2 8 5 /16 30A, 38A, 34ATable PC-15-B — TCX – XL 1200 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0TCX024G 56 1 /2 36 25 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 24 1 /4 17 1 /2 10 3 4 7 /16 30A, 38ATCX030G 56 1 PHASED OUT/2 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 24 7 /8 17 1 /2 10 3 4 7 /16 30A, 38ATCX036G 56 1 /2 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 20 1 /2 25 1 /4 17 1 /2 10 3 4 7 /16 30A, 38ATCX042G 56 1 /2 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 20 1 /2 25 7 /8 17 1 /2 10 3 4 7 /16 30A, 38ATCX048G 65 1 /4 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 25 3 /8 30 1 /4 20 14 3 1 /2 8 5 /16 30A, 38A,34ATCX060G 65 1 /4 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 25 3 /16 28 7 /8 20 14 3 1 /2 8 5 /16 30A, 38A,34ATable PC-15-C — TCP – XE 1200 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0TCP024F 56 1 /2PHASED36 25 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21OUT24 1 /4 17 1 /2 10 3 4 7 /16 30A, 38ATCP030F 56 1 /2 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 24 7 /8 17 1 /2 10 3 4 7 /16 30A, 38ATCP036F 56 1 /2 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 20 1 /2 25 1 /4 17 1 /2 10 3 4 7 /16 30A, 38ATCP042F 56 1 /2 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 20 1 /2 25 7 /8 17 1 /2 10 3 4 7 /16 30A, 38ATCP048F 65 1 /4 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 25 3 /8 30 1 /4 20 14 3 1 /2 8 5 /16 30A, 38A,34ATCP060F 65 1 /4 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 25 3 /16 28 7 /8 20 14 3 1 /2 8 5 /16 30A, 38A,34ATable PC-15-D — TCC – XE 1000 Dimensional Data - Limited Availability 3 Phase Only, 2006Model A B C D E F G H J K L M N P BAYCURB0TCC018F 55 1 /4 36 25 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 5 /16 25 1 /2 17 1 /2 10 3 4 7 /16 30A, 38ATCC024F 55 1 /4PHASED36 25 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 5 /16OUT25 1 /2 17 1 /2 10 3 4 7 /16 30A, 38ATCC030F 55 1 /4 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 20 3 /16 25 5 /16 17 1 /2 10 3 4 7 /16 30A, 38ATCC036F 55 1 /4 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 18 5 /8 24 3 /16 17 1 /2 10 3 4 7 /16 30A, 38ATCC042F 55 1 /4 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 19 24 17 1 /2 10 3 4 7 /16 30A, 38ATCC048F 64 5 /16 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 24 5 /8 28 1 /2 20 14 3 1 /2 8 5 /16 30A, 38A, 34ATCC060F 64 5 /16 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 24 5 /8 28 1 /2 20 14 3 1 /2 8 5 /16 30A, 38A, 34ANote: TCC-F models currently m<strong>an</strong>ufactured with sloped drain p<strong>an</strong>s.For information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleasePC-15 Effective 1/1/06refer to Product Data <strong>an</strong>d/or Installers Guides.


Package Cooling1½ through 5 TonsTCY-G TCX-G TCP-F TCC-FTable PC-16-A — Features 2-5 Ton 2-5 Ton 2-5 Ton 1 1 /2-5 Ton• Impack Plus feature set .............................................................................................................. ✔ ✔ ✔ ✔• Climatuff ® Compressor (1) .............................................................................................................. ✔ ✔ ✔ ✔• Comfort-R TM mode option ............................................................................................................... ✔ — — —• Coil Sav’R TM coil guard ................................................................................................................... ✔ ✔ — —• Direct drive two-speed f<strong>an</strong> motor ..................................................................................................... ✔ — — —• GE ECM variable speed f<strong>an</strong> motor .................................................................................................. ✔ — — —• Heavy vinyl - coated coil guard ........................................................................................................ — — ✔ —• Horizontal convertible to downflow .................................................................................................. ✔ ✔ ✔ ✔• Plate Fin coil .................................................................................................................................... ✔ ✔ ✔ ✔• Polarized plugs ................................................................................................................................ ✔ ✔ ✔ ✔• Powder paint .................................................................................................................................... ✔ ✔ ✔ ✔• 5-year limited compressor only warr<strong>an</strong>ty (Commercial use) ............................................................ ✔ ✔ ✔ ✔• 5-year limited compressor, coil <strong>an</strong>d parts warr<strong>an</strong>ty (<strong>Residential</strong> use) ............................................. — — ✔ ✔• 5-year limited parts warr<strong>an</strong>ty (<strong>Residential</strong> use) ............................................................................... ✔ ✔ — —• 1-year limited coil <strong>an</strong>d parts warr<strong>an</strong>ty (Commercial use) ................................................................ ✔ ✔ ✔ ✔• 10-year limited compressor <strong>an</strong>d outdoor coil warr<strong>an</strong>ty (<strong>Residential</strong> use) ........................................ ✔ ✔ — —Table PC-16-B — Comfort ControlsPHASED OUTAY28X092 ............... Heat/Cool (Horizontal) ....................................................................................... ✔ ✔ ✔BAY28X1821 .......... 1-Stage Heating/Cooling .................................................................................... ✔ ✔ ✔BAY28X1831 .......... 2-Stage Heating/Cooling .................................................................................... ✔ ✔ ✔BAY28X1842 .......... Subbase Auto/M<strong>an</strong>ual Ch<strong>an</strong>geover ................................................................... ✔ ✔ ✔BAY28X1853 .......... Subbase M<strong>an</strong>ual Ch<strong>an</strong>geover ........................................................................... ✔ ✔ ✔BAY28X1872 .......... Subbase Auto Ch<strong>an</strong>geover ................................................................................ ✔ ✔ ✔BAY28X190 ............. Locking Thermostat Cover ................................................................................. ✔ ✔ ✔BAYSTAT0102 ........ Auto 2-Stage Heating/2 Cooling with Economizer ............................................. ✔ ✔ ✔BAYSTAT0082 ........ M<strong>an</strong>ual 1-Stage Heating/1 Cooling .................................................................... ✔ ✔ ✔BAYSTAT0122 ........ M<strong>an</strong>ual 1-Stage Heating/2 Cooling w/economizer ............................................. ✔ ✔ ✔BAYSTAT033A ........ Outdoor Thermostat ........................................................................................... ✔ ✔ ✔BAYSTAT253A ........ Humidity Control ................................................................................................ — — —BAYSTAT304 ........... Cooling Only with F<strong>an</strong> Switch ............................................................................ ✔ ✔ ✔BAYSTAT305 ........... Heat/Cool Vertical .............................................................................................. ✔ ✔ ✔TAYSENS100A ........ Outdoor Temp. Sensor (with case)4 .................................................................. ✔ ✔ ✔TAYSTAT300C ......... XT 300C Prog.,7 Day,A/M 1Htg/1Clg ................................................................ ✔ ✔ ✔TAYSTAT302C ......... XT 302C Prog.,7 Day,A/M 2Htg/2Clg ................................................................ ✔ ✔ ✔TAYSTAT340 ........... Prog., 5/2 Day, M<strong>an</strong>ual Thermostat ................................................................... ✔ ✔ ✔TAYSTAT3713 ......... Electronic 1Htg(Elec)/1Clg (Non Prog) .............................................................. ✔ ✔ ✔TCONT200 .............. 1Heat/1Clg (Gas, Oil or Electric) ....................................................................... ✔ ✔ ✔PHASED OUTTCONT401 .............. 2Heat/1Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔TCONT402 .............. 3Heat/2Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔TCONT600 .............. 1Heat/1Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔TCONT602 .............. 2Heat/2Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔TCONT800 .............. 1Heat/1Clg (Gas, Oil or Electric) ....................................................................... ✔ ✔ ✔1 Requires Subbase.2 Requires BAY24X042 relay kit when used with electric heat.3 Specifically designed for electric heat applications (inst<strong>an</strong>t on f<strong>an</strong>).4 Used with TAYSTAT300C, TAYSTAT302C.See Comfort Controls/Zone Sensors SectionFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.Effective 1/1/06PC-16For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package CoolingConvertible 1½ through 5 TonsTable PC-17-A — Supplementary Heaters – Single Point Entry Kit/Heater MatrixUsed With Single Used WithModel No. Description Power Entry Kit1 Packaged Cooling UnitBAYHTRN105A ..... 3.74/4.98 kW Heater (208/240V 1PH) .......... BAYSPEK047A ....... TCC018-042F1, TCP024-042F1,TCY/TCX024-42G1BAYHTRN108A ..... 5.76/7.68 kW Heater (208/240V 1PH) .......... BAYSPEK047A ....... TCC018-042F1, TCP024-042F1, TCY/TCX024-42G1BAYHTRN110A ..... 7.47/9.96 kW Heater (208/240V 1PH) .......... BAYSPEK047A ....... TCC/TCP024-048F1, TCY/TCX024-60G1BAYSPEK053A ....... TCC/TCP060F1,TCY/TCX060G1BAYHTRN112A ..... 8.65/11.52 kW Heater (208/240V 1PH) ........ BAYSPEK049A ....... TCC/TCP024-048F1, TCY/TCX024-48G1BAYSPEK053A ....... TCC/TCP060F1,TCY/TCX060G1BAYHTRN115A ..... 11.21/14.94 kW Heater (208/240V 1PH) ...... BAYSPEK048A ....... TCC/TCP030-048F1, TCY/TCX030-048G1BAYSPEK052A ....... TCC/TCP060F1,TCY/TCX060G1BAYHTRN117A ..... 12.98/17.28 kW Heater (208/240V 1PH) ...... BAYSPEK048A ....... TCC/TCP030-048F1, TCY/TCX030-060G1BAYSPEK052A ....... TCC/TCP060F1,TCY/TCX060G1BAYHTRN123A ..... 17.2/23.04 kW Heater (208/240V 1PH) ........ BAYSPEK048A ....... TCC/TCP030-48F1,TCY/TCX048G1BAYSPEK052A ....... TCC/TCP060F1,TCY/TCX060G1BAYHTRN306A ..... 4.89/6.25 kW Heater (208/240V 3PH) .......... BAYSPEK047A ....... TCC//TCP036-060F3,TCX036-060G3BAYHTRN310A ..... 7.45/9.96 kW Heater (208/240V 3PH) .......... BAYSPEK047A ....... TCC/TCP036-060F3,TCX036-060G3BAYHTRN315A ..... 11.25/14.90 kW Heater (208/240V 3PH) ...... BAYSPEK047A ....... TCC/TCP036-060F3,TCX036-060G3BAYHTRN320A ..... 14.96/19.92 kW Heater (208/240V 3PH) ...... BAYSPEK051A ....... TCC/TCP042-060F3/TCX042-060G3BAYHTRN330A ..... 22.41/29.80 kW Heater (208/240V 3PH) ...... BAYSPEK050A ....... TCC/TCP060F3,TCX060G3BAYHTRN406A ..... 6kW Heater (480V 3PH) ............................. BAYSPEK047A ....... TCC/TCP036-060F4,TCX036-060G4BAYHTRN410A ..... 9.96 kW Heater (480V 3PH) ....................... BAYSPEK047A ....... TCC/TCP036-060F4,TCX036-060G4BAYHTRN410F ..... 9.96 kW Heater (480V 3PH) ....................... BAYSPEK047A ....... TCC/TCP036-060F4,TCX036-060G4BAYHTRN415A ..... 14.90 kW Heater (480V 3PH) ..................... BAYSPEK047A ....... TCC/TCP036-060F4,TCX036-060G4BAYHTRN420A ..... 19.92 kW Heater (480V 3PH) ..................... BAYSPEK047A ....... TCC/TCP048-060F4,TCX036-060G4BAYHTRN430A ..... 29.80 kW Heater (480V 3PH) ..................... BAYSPEK047A ....... TCC/TCP060F4,TCX060G41 All necessary fuses are included in kitFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-17 Effective 1/1/06


Package CoolingConvertible 1½ through 5 TonsTCY-G TCX-G TCP-F TCC-FTable PC-18-A — Accessories 2-5 2-5 2-5 1½-5BAY24X045 ........... DPDT Relay .................................................................................................... — — — 1½-5BAYASCT001 ........ Anti-Short Cycle Timer69 .............................................................................. 2-5 2-5 2-5 1½-5BAYCCHT003A ..... Cr<strong>an</strong>kcase Heater, 230V7 .............................................................................. 2-4 2-5 2-5 1½-5BAYCCHT202A ..... Cr<strong>an</strong>kcase Heater (230v) ................................................................................ 5 2½-5 2½-5 —BAYCCHT400A ..... Cr<strong>an</strong>kcase Heater (460v) ................................................................................. 3-5 3-5 3-5 —BAYCURB030A ..... Roof Curb (Flat Roof)2 (14 H x 34 W x 53 1/8 L) ............................................ 2-5 2-5 2-5 1½-5BAYCURB033A ..... Roof Curb (Flat Roof)2 Acousti-Curb (14 H x 34 W x 60 5/8 L) ...................... 3-3½ — — —BAYCURB034A ..... Roof Curb (Flat Roof)2 Acousti-Curb (14 H x 43 W x 62 1/16 L) .................... 4-5 4-5 4-5 4-5BAYCURB038A ..... Roof Curb (Flat Roof)2 Acousti-Curb (14 H x 34 W x 53 1/8 L) ...................... 2-5 2-5 2-5 1½-5BAYDMPR040A ..... 0-25% M<strong>an</strong>ual Fresh Air Damper14 .............................................................. 2-3½ 2-3½ 2-3½ 1½-3½BAYDMPR041A ..... 0-25% M<strong>an</strong>ual Fresh Air Damper14 .............................................................. 4-5 4-5 4-5 4-5BAYDMPR050A ..... Motorized Fresh Air Damper1 ....................................................................... 4-5 4-5 4-5 4-5BAYDUCT004A ..... 12" Round Duct Adapters (2 per Box) ............................................................. 2-3½ 2-3½ 2-3½ 1½-3½BAYDUCT005A ..... 14" Round Duct Adapters (1 per Box) ............................................................. 2-3½ 2-3½ 2-3½ 1½-3½BAYECMT002A ..... Extreme Conditions Mounting Kit (Curb Mount) ............................................... 2-5 2-5 2-5 1½-5BAYECMT003A ..... Extreme Conditions Mounting Kit (Slab or Rack Mount) ................................. 2-5 2-5 2-5 1½-5BAYECON054B ..... 0-100% Mod. Economizer with Bar Relief1345 ............................................ 2-3½ 2-3½ 2-3½ 1½-3½BAYECON055B ..... 0-100% Mod. Economizer with Bar Relief1345 ............................................ 4-5 4-5 4-5 4-5BAYECON073A ..... 0-100% Mod. Economizer – Horizontal135 ................................................... 2-5 2-5 2-5 1½-5BAYENTH001A ..... Enthalpy Control (Solid State)3 ...................................................................... 2-5 2-5 2-5 1½-5BAYFLTR012A ....... Filter Frame1 (20 x 25 x 1" filter not included) ................................................ 2-2½ 2-3½ 2½-3½ 2½-3½BAYFLTR013A ....... Filter Frame1 (20 x 25 x 1" filter not included) ................................................ 3-3½ — — —BAYFLTR014A ....... Filter Frame1 (3-10 x 25 x 1" filter not included) ............................................. 4-5 4-5 4-5 4-5BAYFLTR015A ....... Filter Frame1 (20 x 20 x 1" filter not included) ................................................ — 2-5 2 1½-2BAYFLTR017A ....... Filter Frame1 (1-20 x 25 x 2" filter not included) ............................................. 2-2½ 2-3½ 2½-3½ 2½-3½BAYFLTR018A ....... Filter Frame1 (1-20 x 25 x 2" filter not included) ............................................. 3-3½ — — —BAYFLTR019A ....... Filter Frame1 (2-16 x 25 x 2" filter not included) ............................................. 4-5 4-5 4-5 4-5BAYGARD016A ..... Condenser Coil Guard ..................................................................................... — — — 1½-2BAYGARD017A ..... Condenser Coil Guard ..................................................................................... — — — 3 1 /2BAYGARD018A ..... Condenser Coil Guard ..................................................................................... — — — 2½-3BAYGARD021A ..... Condenser Coil Guard ..................................................................................... — — — 4-5BAYHSMT043A ..... High Static Motor (230/460V) 3/4HP ................................................................ — 2½-3½ 2½-3½ 2½-3½BAYHSMT044A ..... High Static Motor (230/460V) 1HP ................................................................... — 4 4-5 4-5BAYHSMT045A ..... High Static Motor (208V) 1HP ......................................................................... — 4 4-5 4-5BAYHSMT056A ..... High Static Motor (208V) 3/4HP ...................................................................... — 2½-3½ 2½-3½ 2½-3½BAYINDK001A* ..... Insulated Deck P<strong>an</strong> for A & B Cabinet ............................................................. 2-5 2-5 2-5 1½-5BAYINDK002A** .... Insulated Deck P<strong>an</strong> for C Cabinet .................................................................... 2-3½ — — —BAYINDK003A*** ... Insulated Deck P<strong>an</strong> for D Cabinet .................................................................... 4-5 4-5 4-5 4-5BAYKSKT010A ...... Quick Start Kit (Single Phase Models Only) .................................................... — — — 1½-5BAYKSKT254 ........ Start Kit - Scroll Models Only(Single Phase Models Only) ............................... — 2½-4 2½-4 —BAYLIFT002B ........ Lifting Lug Kit .................................................................................................. 2-5 2-5 2-5 1½-5BAYLOAM011A ..... Evaporator Defrost Control Kit ......................................................................... 2-5 2-5 2-5 1½-5BAYLOAM323A ..... Dual Voltage Elec. Head Pressure Control (208-230V or 460V)78 .................... 2-5 2-5 2-5 1½-5BAYMOTR307A ..... 200-230V 1/2HP Ball Bearing OD Motor (use with BAYLOAM323A) .................. 2-3½ 2-5 2-5 1½-5BAYMOTR406A ..... 460V 1/2HP Ball Bearing OD Motor (use with BAYLOAM323A) ......................... — 3-5 3-5 1½-5BAYRLAY002 ......... Time Delay Relay ............................................................................................ 2-5 2-5 2-5 —BAYSTAT023 ......... Remote Potentiometer for BAYECON054B, 055B, 073A ................................. 2-5 2-5 2-5 1½-5BAYUTIL030A ....... Roof Curb Utility Extension Kit for BAYCURB030A, 038A ................................ — — — 1½-5BAYUTIL033A ....... Roof Curb Utility Extension Kit for BAYCURB033A .......................................... — — — —BAYUTIL034A ....... Roof Curb Utility Extension Kit for BAYCURB034A .......................................... — — — 4-51 Must use filter frame when economizer/fresh air kit is used.2 Ships knocked down.3 Dry bulb control st<strong>an</strong>dard with economizer.4 Downflow Only.5 2-Stage thermostat provides additional energy savings ifsimult<strong>an</strong>eous economizer <strong>an</strong>d compressor operation is expected.6 Do not use with programmable thermostats.7 Low ambient cooling requires cr<strong>an</strong>kcase heater.8 May require motor ch<strong>an</strong>ge. (See Installers Guide.)9 Activated on Power On.* Currently Shipped with BAYCURB038A.** Currently Shipped with BAYCURB033A.*** Currently Shipped with BAYCURB034A.PHASED OUTFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.Effective 1/1/06PC-18For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Cooling/Electric Heat2 through 4 TonsTCK• Climatuff ® compressor• Compressor motor overload protection• Internal pressure relief valve• Copper tube, aluminum plate fin coils• Shaft-Down OD f<strong>an</strong> system for quietoperation (good neighbor)• Sloped composite drain p<strong>an</strong>• Waterproof closed-cell foam evaporatorbase insulation• Heavy gauge steel cabinet• Weather resist<strong>an</strong>t Powder Paint• Double powder painted G90 base p<strong>an</strong> withdimpled feet• Wrap-around vinyl-coated wire coil guards• U.L. listed• 5-year limited warr<strong>an</strong>ty on compressor <strong>an</strong>d5-year on all other parts (<strong>Residential</strong> use)• Optional extended warr<strong>an</strong>tiesTable PC-19-A — XE 1200 — Cooling - Single Phase (208/230/1/60)Cooling Round Round ShippingUnit Capacity Dimensions (in.) Supply Return Weight SoundTons Model No. SEER/EER* (Btuh) H x W x L Opening Opening (Ibs.) Rating Compressor2 TCK024A100B 12.00/10.49 24,000 31 x 32 x 44 (**) 14" 14" 334 73 R12 1 /2 TCK030A100B 12.00/10.62 30,000 31 x 32 x 44 (**) 14" 14" 341 73 S3 TCK036A100B 12.00/10.63 36,000 31 x 32 x 44 (**) 14" 14" 343 73 S3 1 /2 TCK042A100B 12.00/10.45 41,000 31 x 32 x 44 (**) 14" 14" 351 73 S3 1 /2 TCK042A1H0B 12.00/10.45 41,000 31 x 32 x 44 (**) 14" 14" 351 73 S4 TCK048A100B 11.80/10.33 45,000 31 x 32 x 44 (**) 14" 14" 372 73 STable PC-19-B — Electric Heater DataUsing Single Supply CircuitTCK Cooling/HTGHeater Only Supply CircuitMax Fuse C<strong>an</strong>ada Only Max Fuse C<strong>an</strong>ada OnlyUnit Electric Rated Heater kW or HACR CKT Max. CKT or HACR CKT Max. CKTModel No. Heater Model Voltage 208/240 MCA2 BKR Size4 BKR Size5 MCA6 BKR Size4 BKR Size5TCK024A1 BAYHTRK105A 208/240 3.74/4.98 25/293 25/30 30/30 23/26 25/30 30/30BAYHTRK110A 208/240 7.48/9.96 47/553 50/60 50/60 45/52 45/60 50/60TCK030A1 BAYHTRK105A 208/240 3.74/4.98 25/293 25/30 30/30 23/26 25/30 30/30BAYHTRK110A 208/240 7.48/9.96 48/553 50/60 50/60 45/52 45/60 50/60TCK036A1 BAYHTRK105A 208/240 3.74/4.98 25/293 25/30 30/30 23/26 25/30 30/30BAYHTRK110A 208/240 7.48/9.96 48/553 50/60 50/60 45/52 45/60 50/60TCK042A1 BAYHTRK105A 208/240 3.74/4.98 27/303 30/30 30/30 23/26 25/30 30/30BAYHTRK110A 208/240 7.48/9.96 49/563 50/60 50/60 45/52 45/60 50/60BAYHTRK115A 208/240 11.22/14.94 71/813 80/90 100/100 68/78 70/80 70/100TCK048A16 BAYHTRK106A 208/240 3.74/4.98 26/303 30/30 30/30 23/26 25/30 30/30BAYHTRK110A 208/240 7.48/9.96 50/603 50/60 50/60 45/52 45/60 50/60BAYHTRK115A 208/240 11.22/14.94 71/813 80/90 100/100 68/78 70/80 70/100NOTES:1 Any power supply <strong>an</strong>d circuits must be wired <strong>an</strong>d protected in accord<strong>an</strong>ce with local electrical codes.2 The MCA values listed are for electric heater <strong>an</strong>d cooling unit.3 Field wire must be rated at least 75°C.4 The HACR circuit breaker is for U.S.A. installations only.5 For C<strong>an</strong>ada installation reference only6 BAYHTRK106A only approved for TCK048A17 The MCA values listed are for electric heater only.8 The MCA values listed are for electric heater <strong>an</strong>d heat pump.For information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.TCK-A models will be upgraded in the 1st Quarter of 2006.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-19 Effective 1/1/06


Package Cooling/Electric Heat2 through 4 TonsTable PC-20-A — Accessories/Comfort ControlsModel No. Description Used WithAY28X092 Heat/Cool (Horizontal) Therm. All Cooling ModelsBAY28X1821 1-Stage Heating/Cooling Therm. All Cooling ModelsBAY28X1831 2-Stage Heating/Cooling Therm. All Cooling ModelsBAY28X1842 Subbase Auto/M<strong>an</strong>. Ch<strong>an</strong>geover BAY28X183BAY28X1853 Subbase M<strong>an</strong>. Ch<strong>an</strong>geover BAY28X182,183BAY28X1872 Subbase Auto Ch<strong>an</strong>geover BAY28X182,183BAY28X1904 Locking Thermostat Cover All Room ThermostatsBAYCOVR100A Wallcover Plate TAYSTAT371BAYECMT002A Extreme Conditions Mounting Kit (Curb Mount) All TCK ModelsBAYECMT003A Extreme Conditions Mounting Kit (Slab <strong>an</strong>d Rack Mount) All TCK ModelsBAYSTAT304 Cooling only with F<strong>an</strong> Switch All Cooling ModelsBAYSTAT305 Heat/Cool Vertical All Cooling ModelsTAYSENS100A Outdoor Temperature Sensor (with case) TAYSTAT300TAYSTAT300C XT300C Prog.,7 Day,A/M,1Htg./Clg. All Cooling ModelsTAYSTAT340 Prog.,5/2 Day,M<strong>an</strong>ual,1 Htg./Clg. All Cooling ModelsTAYSTAT3713 Electronic,1Htg(Elec)/1Clg (Non Prog) All Cooling ModelsTCONT200A 1Heat/1Clg (Gas, Oil or Electric) All Cooling ModelsTCONT401A 2Heat/1Clg (Heat Pump/A/C) All Cooling ModelsTCONT402A 3Heat/2Clg (Heat Pump/A/C) All Cooling ModelsTCONT600A 1Heat/1Clg (Heat Pump/A/C) All Cooling Models1 Requires subbase.2 Requires BAY24X042 relay when used with electric heaters.3 Specially designed for electric heater application (inst<strong>an</strong>t on f<strong>an</strong>).4 Not for use with programmable thermostats.A/M = Automatic or M<strong>an</strong>ual Ch<strong>an</strong>geover* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.For information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.TCK-A models will be upgraded in the 1st Quarter of 2006.Effective 1/1/06PC-20For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Cooling – M<strong>an</strong>ufacturedHousing 2½ through 4 TonsTCM• Climatuff ® compressor• High efficiency perform<strong>an</strong>ce• Round duct connections for M<strong>an</strong>ufacturedHousing• Quiet operating top condenserair discharge• Copper tube/aluminum fin coils• Totally enclosed, perm<strong>an</strong>ently lubricatedcondenser f<strong>an</strong> motor• Hermetically sealed compressorwith internal relief valve• Two-Speed evaporator blower motor• Sloped Drain P<strong>an</strong>• Fully charged R-22 system• Heavy gauge steel cabinet with weatherresist<strong>an</strong>t, baked enamel finish• Protected pressure taps forrefriger<strong>an</strong>t checks• Fully insulated air h<strong>an</strong>dling compartment• Convenient access p<strong>an</strong>els• 5-year limited compressor warr<strong>an</strong>ty(<strong>Residential</strong> use)• 5-year limited coil <strong>an</strong>d parts warr<strong>an</strong>ty(<strong>Residential</strong> use)Table PC-21-A — TCM (208-230/1/60)Cooling Cabinet Round Round ShippingUnit Capacity Dimensions (in.) Supply Return Weight Max SoundModel No. SEER/EER* (Btuh) H x W x L Opening Opening (Ibs.) MCA* Fuse* Rating CompressorTCM030F100B 9.7/9.10PHASED29,800 29 x 36 x 55 (B) 12 12OUT358 22.7 35 80 R1TCM036F100B 9.7/8.75 35,200 29 x 36 x 55 (B) 12 12 380 26.8 45 80 R1TCM042F100B 9.7/8.60 40,500 29 x 36 x 55 (B) 14 14 383 31.8 50 80 R2TCM048F100B 9.7/8.90 46,500 29 x 36 x 63 (C) 14 14 461 33.0 50 82 R2Table PC-21-B — Supplementary Heaters – Heater MatrixModel No. Description Used WithBAYHTRN105A 3.74/4.98 kW Heater (208/240 volt) TCM030, 036, 042FBAYHTRN108A 5.76/7.68PHASEDkW Heater (208/240 volt)OUTTCM030, 036, 042FBAYHTRN110A 7.47/9.96 kW Heater (208/240 volt) TCM030, 036, 042, 048FBAYHTRN112A 8.65/11.52 kW Heater (208/240 volt) TCM030, 036, 042FBAYHTRN115A 11.21/14.94 kW Heater (208/240 volt) TCM030, 036, 042FBAYHTRN117A 12.98/17.28kW Heater (208/240 volt) TCM030, 036, 042, 048FTable PC-21-C — AccessoriesModel No. Description Used WithBAYCCHT003A Cr<strong>an</strong>kcase Heater (230 volt) All TCM-F ModelsBAYECMT002A Extreme Conditions Mounting Kit (Curb Mount) All TCM ModelsBAYECMT003A Extreme Conditions Mounting Kit (Slab <strong>an</strong>d Rack Mount) All TCM ModelsBAYFLTR012A Filter Frame (20x25x1" filer not included) TCM030, 036, 042FBAYFLTR013A FilterPHASEDFrame (20x25x1" filer not included)OUTTCM042FBAYGARD017A Condenser Coil Guard TCM042, 048FBAYGARD018A Condenser Coil Guard TCM030, 036FBAYHSMT043A High Static Motor All TCM-F ModelsBAYHSMT044A High Static Motor All TCM-F ModelsBAYHSMT045A High Static Motor All TCM-F ModelsBAYHSMT056A High Static Motor All TCM-F ModelsBAYKSKT010A Quick Start Kit All TCM-F ModelsTable PC-21-D — Comfort ControlsModel No. Description Used WithAY28X092 Heat/Cool Horizontal All TCM-F ModelsBAYSTAT304 Cooling Only with F<strong>an</strong> Switch All TCM-F ModelsBAYSTAT305 Heat/CoolPHASEDVerticalOUTAll TCM-F ModelsBAYSTAT033A Outdoor Thermostat All TCM-F ModelsTCONT200A 1Heat/1Clg All TCM-F ModelsTCONT401A 2Heat/1Clg All TCM-F ModelsTCONT402A 3Heat/2Clg All TCM-F ModelsTCONT600A 1Heat/1Clg All TCM-F Models* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = ScrollFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-21 Effective 1/1/06


Package CoolingOver/Under 2 through 5 TonsTCH• Climatuff ® compressor• Compressor motoroverload protection• Internal pressure reliefvalve• Copper tube, aluminumplate fin coils• Pressure taps forrefriger<strong>an</strong>t check• Top discharge condensingf<strong>an</strong>• Indoor f<strong>an</strong> relay• Top access to supplementaryheater• Polarized plug for easyfield connection of lowvoltage to supplementaryheaters• Over (supply) under(return) airconfiguration• Wrap around coil guard• Exp<strong>an</strong>sion valve onindoor coil• Heavy gauge steelcabinet• Multi-speed direct driveblower Variable speeddirect drive blower motorton TCH-048-060F models• Factory installed coilguard• Low ambient cooling to45° F as m<strong>an</strong>ufactured• UL listed• 5 year limited warr<strong>an</strong>tyon compressor <strong>an</strong>d 5year on all other parts(residential use only)• Optional extendedwarr<strong>an</strong>ties• Energy Star ListedTable PC-22-A — TCH – Over/Under Horizontal UnitPower Supply Nom. Cap. ShippingUnit Volts Cooling Dimensions (in.) Weight Max SoundModel No. Phase/Hz SEER/EER* (Btuh) H x W x L (Ibs.) MCA* Fuse* Rating Comp.Single PhaseTCH024B100B 208-230/1/60 12.05/11.00 24,000 30 3 /8 x 31 5 /8 x 44 319 17.2 25 79 R1TCH030B100B 208-230/1/60 12.6/11.00 30,000 30 3 /8 x 31 5 /8 x 44 335 19.3 30 82 R2TCH036B100C 208-230/1/60 12.0/11.30 36,000 30 3 /8 x 31 5 /8 x 44 370 25.5 40 82 R2TCH042B100B 208-230/1/60 12.5/11.00 41,500 30 3 /8 x 31 5 /8 x 44 374 24.1 40 82 R2TCH048F100A 208-230/1/60 13.75/12.35 50,000 33 x 45 x 58 504 37 50 84 STCH060F100A 208-230/1/60 13.00/11.45 62,000 33 x 45 x 58 509 47 60 84 STons Supply H x W Return H x W2 – 3 1 /2 8 3 /8 x 27 3 /8 16 3 /4 x 27 3 /84 – 5 8 1 /2 x32 1 /32 19 15 /16 x 32 1 /32Table PC-22-B — TCH – Over/Under Horizontal UnitPower Supply Nom. Cap. Dimensions ShippingUnit Volts Perform<strong>an</strong>ce Cooling (in.) Weight Max SoundTons Model No. Phase/Hz SEER (Btuh) H x W x L (Ibs.) MCA* Fuse* RatingThree Phase3 TCH036B300C 208-230/3/60 11.4 36,000 30 3 /8 x 31 5 /8 x 44 370 17.8 25 823 1 /2 TCH042B300B 208-230/3/60 12.5 41,500 30 3 /8 x 31 5 /8 x 44 374 18.1 25 823 TCH036B400C 460/3/60 11.4 36,000 30 3 /8 x 31 5 /8 x 44 370 9.7 15 823 1 /2 TCH042B400B 460/3/60 12.5 41,500 30 3 /8 x 31 5 /8 x 44 374 9.9 15 82Tons Supply H x W Return H x W3 – 3 1 /2 8 3 /8 x 27 3 /8 16 3 /4 x 27 3 /8Dimensions are in inches. See Outline Dimensions.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.Top Diagram OnlyFor information on Roof Curbs <strong>an</strong>dRoof Curb Adaptors, please refer tothe Accessories/Information Tab.311mm[12-1/4]TCH-B models will be upgraded inthe 1st Quarter of 2006.Effective 1/1/06PC-22LEFT SIDEFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package CoolingOver/Under 2 through 5 TonsTable PC-23-A — Supplementary Heaters – Heater MatrixModel No. Power Supply kW Rating Used WithBAYHTRC106A 208/240/1/60 4.33/5.76 kW TCH024-042B100A, 048F, 060F100ABAYHTRC108A 208/240/1/60 6.12/8.16 kW TCH024-042B100ABAYHTRC110A 208/240/1/60 7.93/10.56 kW TCH048F1 onlyBAYHTRC111A 208/240/1/60 7.93/10.56 kW TCH024-042B100A, 060F1BAYHTRC112A 208/240/1/60 8.65/11.52 kW TCH024-042B100ABAYHTRC117A1 208/240/1/60 12.98/17.28kW TCH030-042B100A, 048F, 060F1BAYHTRC306A 208/240/3/60 4.33/5.76 TCH036-042B300ABAYHTRC312A 208/240/3/60 8.65/11.52 TCH036-042B300ABAYHTRC317A 208/240/3/60 12.98/17.28 TCH036-042B300ABAYHTRC406A 480/3/60 5.76 TCH036-042B400ABAYHTRC412A 480/3/60 11.52 TCH036-042B400ABAYHTRC417A 480/3/60 17.28 TCH036-042B400ATable PC-23-B — Accessories/Comfort ControlsModel No. Description Used WithAY28X092 ............................. Heat/Cool (Horizontal) Thermostat .......................................... All Cooling ModelsBAY24X042 .......................... DPDT F<strong>an</strong> <strong>an</strong>d Electric Heat Relay ......................................... Auto Ch<strong>an</strong>geover T-StatBAY28X1822 ...................... 1-Stage Heating/Cooling Thermostat ...................................... All Cooling ModelsBAY28X1843 ...................... Subbase Automatic/M<strong>an</strong>ual Ch<strong>an</strong>geover ................................ BAY28X182BAY28X1854 ...................... Subbase M<strong>an</strong>ual Ch<strong>an</strong>geover ................................................. BAY28X182BAY28X1873 ...................... Subbase Automatic Ch<strong>an</strong>geover ............................................. BAY28X182BAY28X190 ......................... Locking Thermostat Cover ...................................................... All Room ThermostatsBAY41X171A ........................ 5 or 7 Minute Delay Relay ....................................................... All TCH ModelsBAYASCT00156 ................. Anti-Short Cycle Timer ............................................................ All TCH ModelsBAYECMT002A .................... Extreme Conditions Mounting Kit (Curb Mount) ...................... All TCH ModelsBAYECMT003A .................... Extreme Conditions Mounting Kit (Slab <strong>an</strong>d Rack Mount) ...... All TCH ModelsBAYLOAM011A .................... Low Ambient Cooling Kit ......................................................... All TCH ModelsBAYSTAT304 ........................ Cooling Only with F<strong>an</strong> Switch .................................................. All Cooling ModelsBAYSTAT305 ........................ Heat/Cool Vertical ................................................................... All Cooling ModelsTAYASCT501A56 ................ Anti-Short Cycle Timer ............................................................ All Cooling ModelsTAYSENS100A ..................... Outdoor Temp. Sensor (with case) .......................................... TAYSTAT300C,302CTAYSTAT300C ....................... XT300C Prog.,7 Day,A/M,1Htg/1Clg ....................................... All Cooling ModelsTCONT200A ......................... 1Heat/1Clg (Gas, Oil or Electric) ............................................. All Cooling ModelsTCONT401A ......................... 2Heat/1Clg (Heat Pump/A/C) .................................................. All Cooling ModelsTCONT402A ......................... 3Heat/2Clg (Heat Pump/A/C) .................................................. All Cooling ModelsTCONT600A ......................... 1Heat/1Clg (Heat Pump/A/C) .................................................. All Cooling Models1 This model has a fuse box factory installed.2 Requires subbase.3 Requires BAY24X042 relay when used with electric heaters.4 Specially designed for electric heater application (inst<strong>an</strong>t on f<strong>an</strong>).5 Not for use with programmable thermostats.6 Activated on Power Off.For information on Roof Curbs <strong>an</strong>dRoof Curb Adaptors, please refer tothe Accessories/Information Tab.TCH-B models will be upgradedin the 1st quarter of 2006.422mm[16-5/8]RIGHT SIDEFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-23 Effective 1/1/06


Precedent 3-10 tonPackaged CoolingFeaturingA New Look for a New CenturyBeveled TopSmoother DesignSmall compact cabinetRecessed access h<strong>an</strong>dlesSt<strong>an</strong>dard Features:• <strong>Tr<strong>an</strong>e</strong> built scroll compressors on all 3-10 ton units except 3 ton st<strong>an</strong>dard efficiencymodel (Reciprocating Compressor)• Colored <strong>an</strong>d numbered wiring• Provisions for through the Base Condensate Drain Connections• Patented Hybrid Condenser Coil for easy cle<strong>an</strong>ing• 1" throwaway filters provided on 3-5 ton units• 2" throwaway filters provided on 6-10 ton units• Liquid Line Refriger<strong>an</strong>t Drier• Operating Charge of R-22 or R-410A• IAQ Sloped Drain P<strong>an</strong>s• Single point power for Electric Heat• Low Ambient to 40°F on Electromech<strong>an</strong>ical models• Low Ambient to 0°F on Microprocessor models• 5 - year Limited Compressor Warr<strong>an</strong>ty• 1 - year Limited Parts Warr<strong>an</strong>tyAdded Flexibility• Electromech<strong>an</strong>ical or ReliaTel controls (See page PC-35 for ReliaTelControl Information)• St<strong>an</strong>dard or high efficiency cooling models available• Convertible airflow (ships in downflow application)• Fork lift openings on three sides of unit• Direct or belt drive - st<strong>an</strong>dard or oversized motors (Direct for 3-5 ton only)• We don’t prepackage options• Choose options tailored to suit each job —pay only for what is needed• Units ship with options installed —<strong>an</strong>d within our st<strong>an</strong>dard ship cycle timeFactory Installed Options• Through-the-Base — Electrical• Convenience Outlet — Powered or unpowered• Unit Disconnect Switch• Smoke Detectors — Supply, return, or both• Condenser Coil Coating• Hinged Access Service P<strong>an</strong>els• Discharge Air Sensor• F<strong>an</strong> Fail <strong>an</strong>d Clogged Filter Switches• Condenser Coil Guard — Hail Protection Quality• TXV thermal exp<strong>an</strong>sion valve <strong>an</strong>d split face evaporator coil• Dehumidification Hot Gas Reheat Coil• Novar Controls• TCI (<strong>Tr<strong>an</strong>e</strong> Communication Interface)• LonTalk (Communication Interface)• 2" Pleated Media filters• Phase MonitorThe same <strong>Tr<strong>an</strong>e</strong> Quality <strong>an</strong>dReliability … with added Flexibility!Effective 1/1/06PC-24For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Precedent Packaged CoolingConvertible 3-10 TonsTable PC-25-A — Base Unit — St<strong>an</strong>dard Efficiency — Electromech<strong>an</strong>icalCooling Cabinet ShippingUnit Perform<strong>an</strong>ce3 Capacity Dimensions (in.) Downflow Downflow Weight Max2Tons Ordering No.4 SEER/EER (Btuh) H x W x L Supply Return (Ibs.) MCA* Fuse*TSC – 208-230/1/60 – Single Phase – No Heat3 TSC036E1E0A0000 13.0 35,620 32 x 44 x 70 18 x 15.5 24 x 14 555 27.2 404 TSC048E1E0A0000 13.0 49,210 32 x 44 x 70 18 x 15.5 24 x 14 586 35.2 505 TSC060E1E0A0000 13.0 58,000 32 x 44 x 70 18 x 15.5 24 x 14 636 43.8 70TSC – 208-230/3/60 – Three Phase – No Heat3 TSC036A3E0A0000 10.7 37,400 32 x 44 x 70 18 x 15.5 24 x 14 501 17.9 254 TSC048A3E0A0000 10.0 49,200 32 x 44 x 70 18 x 15.5 24 x 14 526 23.9 355 TSC060A3E0A0000 10.2 63,100 32 x 44 x 70 18 x 15.5 24 x 14 543 31.5 503 TSC036E3E0A0000 13.0 37,150 32 x 44 x 70 18 x 15.5 24 x 14 555 21.4 304 TSC048E3E0A0000 13.0 49,450 32 x 44 x 70 18 x 15.5 24 x 14 586 25.2 355 TSC060E3E0A0000 13.0 62,270 32 x 44 x 70 18 x 15.5 24 x 14 636 29.5 456 TSC072A3E0A0000 10.3 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 824 32.7 507 1 /2 TSC090A3E0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 897 42.7 607 1 /2 TSC092A3E0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 899 38.9 508 1 /2 TSC102A3E0A0000 10.3 105,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 978 45.1 6010 TSC120A3E0A0000 10.4/10.31 117,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1052 52.6 60TSC – 460/3/60 – Three Phase – No Heat3 TSC036A4E0A0000 10.7 37,400 32 x 44 x 70 18 x 15.5 24 x 14 501 9.2 154 TSC048A4E0A0000 10.0 49,200 32 x 44 x 70 18 x 15.5 24 x 14 526 12.8 205 TSC060A4E0A0000 10.2 63,100 32 x 44 x 70 18 x 15.5 24 x 14 543 16.0 253 TSC036E4E0A0000 13.0 37,150 32 x 44 x 70 18 x 15.5 24 x 14 555 10.1 154 TSC048E4E0A0000 13.0 49,450 32 x 44 x 70 18 x 15.5 24 x 14 586 12.5 155 TSC060E4E0A0000 13.0 62,270 32 x 44 x 70 18 x 15.5 24 x 14 636 15.5 256 TSC072A4E0A0000 10.3 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 824 17.6 257 1 /2 TSC090A4E0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 897 22.6 357 1 /2 TSC092A4E0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 899 20.5 258 1 /2 TSC102A4E0A0000 10.3 105,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 978 24.0 3010 TSC120A4E0A0000 10.4/10.31 117,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1052 26.9 35TSC – 575/3/60 – Three Phase – No Heat3 TSC036AWE0A0000 10.7 37,400 32 x 44 x 70 18 x 15.5 24 x 14 501 7.7 154 TSC048AWE0A0000 10.0 49,200 32 x 44 x 70 18 x 15.5 24 x 14 526 9.8 155 TSC060AWE0A0000 10.2 63,100 32 x 44 x 70 18 x 15.5 24 x 14 543 12.2 153 TSC036EWE0A0000 13.0 37,150 32 x 44 x 70 18 x 15.5 24 x 14 555 8.0 154 TSC048EWE0A0000 13.0 49,450 32 x 44 x 70 18 x 15.5 24 x 14 586 9.0 155 TSC060EWE0A0000 13.0 62,270 32 x 44 x 70 18 x 15.5 24 x 14 636 10.1 156 TSC072AWE0A0000 10.3 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 824 12.8 207 1 /2 TSC090AWE0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 897 17.6 257 1 /2 TSC092AWE0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 899 15.5 208 1 /2 TSC102AWE0A0000 10.3 105,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 978 19.5 2510 TSC120AWE0A0000 10.4/10.31 117,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1052 21.8 251 Upflow/Horizontal.2 HACR breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.4 Digit 7-A=R-22 or E=410A* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-25 Effective 1/1/06


Precedent Packaged CoolingConvertible 3-10 TonsTable PC-26-A — Base Unit — St<strong>an</strong>dard Efficiency — ReliaTel Microprocessor ControlsCooling Cabinet ShippingUnit Perform<strong>an</strong>ce3 Capacity Dimensions (in.) Downflow Downflow Weight Max2Tons Ordering No.4 SEER/EER (Btuh) H x W x L Supply Return (Ibs.) MCA* Fuse*TSC – 208-230/1/60 – Single Phase – No Heat3 TSC036E1R0A0000 13.0 35,620 32 x 44 x 70 18 x 15.5 24 x 14 555 27.2 404 TSC048E1R0A0000 13.0 49,210 32 x 44 x 70 18 x 15.5 24 x 14 586 35.2 505 TSC060E1R0A0000 13.0 58,000 32 x 44 x 70 18 x 15.5 24 x 14 636 43.8 70TSC – 208-230/3/60 – Three Phase – No Heat3 TSC036A3R0A0000 10.7 37,400 32 x 44 x 70 18 x 15.5 24 x 14 501 17.9 254 TSC048A3R0A0000 10.0 49,200 32 x 44 x 70 18 x 15.5 24 x 14 526 23.9 355 TSC060A3R0A0000 10.2 63,100 32 x 44 x 70 18 x 15.5 24 x 14 543 31.5 503 TSC036E3R0A0000 13.0 37,150 32 x 44 x 70 18 x 15.5 24 x 14 555 21.4 304 TSC048E3R0A0000 13.0 49,450 32 x 44 x 70 18 x 15.5 24 x 14 586 25.2 355 TSC060E3R0A0000 13.0 62,270 32 x 44 x 70 18 x 15.5 24 x 14 636 29.5 456 TSC072A3R0A0000 10.3 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 824 32.7 507 1 /2 TSC090A3R0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 897 42.7 607 1 /2 TSC092A3R0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 899 38.9 508 1 /2 TSC102A3R0A0000 10.3 105,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 978 45.1 6010 TSC120A3R0A0000 10.4/10.31 117,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1052 52.6 60TSC – 460/3/60 – Three Phase – No Heat3 TSC036A4R0A0000 10.7 37,400 32 x 44 x 70 18 x 15.5 24 x 14 501 9.2 154 TSC048A4R0A0000 10.0 49,200 32 x 44 x 70 18 x 15.5 24 x 14 526 12.8 205 TSC060A4R0A0000 10.2 63,100 32 x 44 x 70 18 x 15.5 24 x 14 543 16.0 253 TSC036E4R0A0000 13.0 37,150 32 x 44 x 70 18 x 15.5 24 x 14 555 10.1 154 TSC048E4R0A0000 13.0 49,450 32 x 44 x 70 18 x 15.5 24 x 14 586 12.5 155 TSC060E4R0A0000 13.0 62,270 32 x 44 x 70 18 x 15.5 24 x 14 636 15.5 256 TSC072A4R0A0000 10.3 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 824 17.6 257 1 /2 TSC090A4R0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 897 22.6 357 1 /2 TSC092A4R0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 899 20.5 258 1 /2 TSC102A4R0A0000 10.3 105,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 978 24.0 3010 TSC120A4R0A0000 10.4/10.31 117,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1052 26.9 35TSC – 575/3/60 – Three Phase – No Heat3 TSC036AWR0A0000 10.7 37,400 32 x 44 x 70 18 x 15.5 24 x 14 501 7.7 154 TSC048AWR0A0000 10.0 49,200 32 x 44 x 70 18 x 15.5 24 x 14 526 9.8 155 TSC060AWR0A0000 10.2 63,100 32 x 44 x 70 18 x 15.5 24 x 14 543 12.2 153 TSC036EWR0A0000 13.0 37,150 32 x 44 x 70 18 x 15.5 24 x 14 555 8.0 154 TSC048EWR0A0000 13.0 49,450 32 x 44 x 70 18 x 15.5 24 x 14 586 9.0 155 TSC060EWR0A0000 13.0 62,270 32 x 44 x 70 18 x 15.5 24 x 14 636 10.1 156 TSC072AWR0A0000 10.3 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 824 12.8 207 1 /2 TSC090AWR0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 897 17.6 257 1 /2 TSC092AWR0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 899 15.5 208 1 /2 TSC102AWR0A0000 10.3 105,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 978 19.5 2510 TSC120AWR0A0000 10.4/10.31 117,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1052 21.8 251 Upflow/Horizontal.2 HACR breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.4 Digit 7-A=R-22 or E=410A* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.Effective 1/1/06PC-26For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Precedent Packaged CoolingConvertible 3-10 TonsTable PC-27-A — Base Unit — High Efficiency — Electromech<strong>an</strong>icalCooling Cabinet ShippingUnit Perform<strong>an</strong>ce3 Capacity Dimensions (in.) Downflow Downflow Weight Max1Tons Ordering No. SEER/EER (Btuh) H x W x L Supply Return (Ibs.) MCA* Fuse*THC – 208-230/3/60 – Three Phase – No Heat6 THC072A3E0A0000 11.5/11.32 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 861 34.8 507 1 /2 THC092A3E0A0000 11.5/11.32 90,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 899 38.1 508 1 /2 THC102A3E0A0000 11.5/11.32 102,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1036 42.3 5010 THC120A3E0A0000 11.2/10.72 116,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1125 48.6 60THC – 460/3/60 – Three Phase – No Heat6 THC072A4E0A0000 11.5/11.32 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 861 17.5 257 1 /2 THC092A4E0A0000 11.5/11.32 90,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 899 19.4 258 1 /2 THC102A4E0A0000 11.5/11.32 102,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1036 21.4 2510 THC120A4E0A0000 11.2/10.72 116,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1125 25.3 30THC – 575/3/60 – Three Phase – No Heat6 THC072AWE0A0000 11.5/11.32 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 861 13.5 207 1 /2 THC092AWE0A0000 11.5/11.32 90,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 899 14.8 158 1 /2 THC102AWE0A0000 11.5/11.32 102,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1036 16.6 2010 THC120AWE0A0000 11.2/10.72 116,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1125 19.9 251 HACR breaker per NEC.2 Downflow Airflow/Horizontal Airflow.3 SEER applies, 3-5 tons; EER applies 6-10 tons.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-27 Effective 1/1/06


Precedent Packaged CoolingConvertible 3-10 TonsTable PC-28-A — Base Unit — High Efficiency — ReliaTel Microprocessor ControlsCooling Cabinet ShippingUnit Perform<strong>an</strong>ce3 Capacity Dimensions (in.) Downflow Downflow Weight Max1Tons Ordering No. SEER/EER (Btuh) H x W x L Supply Return (Ibs.) MCA* Fuse*THC – 208-230/3/60 – Three Phase – No Heat6 THC072A3R0A0000 11.5/11.32 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 861 34.8 507 1 /2 THC092A3R0A0000 11.5/11.32 90,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 899 38.1 508 1 /2 THC102A3R0A0000 11.5/11.32 102,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1036 42.3 5010 THC120A3R0A0000 11.2/10.72 116,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1125 48.6 60THC – 460/3/60 – Three Phase – No Heat6 THC072A4R0A0000 11.5/11.32 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 861 17.5 257 1 /2 THC092A4R0A0000 11.5/11.32 90,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 899 19.4 258 1 /2 THC102A4R0A0000 11.5/11.32 102,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1036 21.4 2510 THC120A4R0A0000 11.2/10.72 116,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1125 25.3 30THC – 575/3/60 – Three Phase – No Heat6 THC072AWR0A0000 11.5/11.32 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 861 13.5 207 1 /2 THC092AWR0A0000 11.5/11.32 90,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 899 14.8 158 1 /2 THC102AWR0A0000 11.5/11.32 102,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1036 16.6 2010 THC120AWR0A0000 11.2/10.72 116,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1125 19.9 251 HACR breaker per NEC.2 Downflow Airflow/Horizontal Airflow.3 SEER applies, 3-5 tons; EER applies 6-10 tons.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory productioEffective 1/1/06PC-28For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Digit Description Order Number1-8 Main Assembly (see previous page)9 Unit ControlsElectro-Mech<strong>an</strong>ical ......................................................... EUnit Controls -ReliaTel Micro-processor ....................... R10 (See Heater Table below)11 Minor Design SequenceFirst Sequence .............................................................. A12-13 Service SequenceFirst Sequence (Factory Supplied) ................................. ✱,✱14 Fresh Air SelectionNo Fresh Air ................................................................... 00-50% M<strong>an</strong>ual Outside Air Damperw .............................. A0-50% Motorized Outside Air Damper .............................. B0-100% Economizer, Dry Bulb withoutBarometric Relief 2 .................................................... C0-100% Economizer, Dry Bulb withBarometric Relief2 .................................................... D0-100% Economizer, Reference Enthalpywithout Barometric Relief12 ....................................... E0-100%Economizer, Reference Enthalpywith Barometric Relief12 ........................................... F0-100%Economizer, Comparative Enthalpywithout Barometric Relief 12 ..................................... G0-100%Economizer, Comparative Enthalpywith Barometric Relief 12 ......................................... H15 Supply F<strong>an</strong>/Drive Type/MotorSt<strong>an</strong>dard Drive ............................................................... 0Oversized Motor ............................................................. 1Optional Belt Drive Motor (3 phase only) .......................... 216 Hinged Service Access & FiltersSt<strong>an</strong>dard P<strong>an</strong>els & Filters ................................................ 0Hinged Access P<strong>an</strong>els & St<strong>an</strong>dard Filters ........................ ASt<strong>an</strong>dard P<strong>an</strong>els & 2" Pleated Filters ............................... BHinged Access P<strong>an</strong>els & 2" Pleated Filters ...................... C17 Condenser Coil ProtectionSt<strong>an</strong>dard Coil ................................................................. 0St<strong>an</strong>dard Coil with Hail Guard .......................................... 1Epoxy Coated Condenser Coil ........................................ 2Epoxy Coated Condenser Coil with Hail Guard ................ 318 Through the Base ProvisionsNo Through the Base Provisions ..................................... 0Through the Base Electricr ............................................ A19 Disconnect/Circuit Breaker /Phase Monitor (3 phase only)No Disconnect/ Circuit Breaker/No Phase Monitor ............ 0Non-Fused Disconnectr ................................................ 11 Enthalpy control not available factory installed with electro-mech<strong>an</strong>ical controls.2 Economizer with Barometric Relief is for downfllow configured units only. Order Economizer withoutBarometric Relief for horizontal configuration. Barometric relief for horizontal configured units must be orderedas field installed accessory BAYBARM010A.3 Requires use of Disconnect or Circuit Breaker.4 St<strong>an</strong>dard refrigeration metering device - short orifice.5 Frostat c<strong>an</strong>not be field installed in electro-mech<strong>an</strong>ical units.6 High Pressure control is st<strong>an</strong>dard on 3 phase units with scroll compressors <strong>an</strong>d in TSC036A.7 Not available with BAYFRST001A High Temperature Stat accessory.8 The return air smoke detector may not fit up or work properly on the Convertible units when used inconjunction with 3rd party accessories such as bolt on heat wheels, economizers <strong>an</strong>d power exhaust. Do notHeaters (Digit 10)kW Nominal No.Rating Digit BTUH Stages Used With208/240/1/603.7/5.0 (A) 12,800/17,100 1 T*C036-060A17.5/10.0 (D) 25,600/34,100 2 T*C036-060A110.3/13.8 (F) 35,300/47,100 2 T*C036-060A113.2/17.6 (G) 45,100/60,100 2 T*C048-060A1208/240/3/604.5/6.0 (B) 13,400/20,500 1 T*C036-060A39.0/12.0 (E) 30,800/59,400 2 T*C036-060A313.2/17.6 (G) 44,600/59,400 2 T*C036-060A317.2/23.0 (J) 58,900/78,500 2 T*C060A36.75/9.0 (C) 23,000/30,700 1 T*C072-102A313.5/18.0 (G) 46,100/61,400 1 T*C072-120A320.3/27.0 (K) 69,000/92,100 2 T*C072-120A327.0/36.0 (N) 92,200/122,900 2 T*C072-120A340.5/54.0 (P) 138,200/184,300 2 T*C120A3For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.Precedent PackagedCooling Convertible 3-10 Tons(Model Digit Numbers)Digit Description Order NumberCircuit Breakerr ............................................................. 2Phase Monitort ............................................................. 3Phase Monitort & Non-Fused Disconnect Switch ............ 4Phase Monitort & Circuit Breaker ................................... 520 Convenience OutletNo Convenience Outlet ................................................... 0Unpowered Convenience Outlet ...................................... APowered Convenience Outlet (3 phase only)3 ................ B21 Communications OptionsyNo Communications Interface ......................................... 0<strong>Tr<strong>an</strong>e</strong> Communications Interface ..................................... 1LonTalk ® Communications Interface ................................. 2Novar 2024 Controls ....................................................... 3Novar 3051 Controls ....................................................... 422 Refrigeration System OptionSt<strong>an</strong>dard Refrigeration System ........................................ 0Thermal Exp<strong>an</strong>sion Valve (TXV) ...................................... ADehumidification (Hot Gas Reheat Coil)e ....................... B23 Refrigeration ControlsNo Refrigeration Control .................................................. 0High Pressure Control6y .............................................. 1Frostat5 ........................................................................ 2Cr<strong>an</strong>kcase Heater ........................................................... 3High Pressure Control6y <strong>an</strong>d Frostat5 ......................... 4High Pressure Control6y <strong>an</strong>d Cr<strong>an</strong>kcase Heater ............ 5Frostat5 <strong>an</strong>d Cr<strong>an</strong>kcase Heater6 .................................. 6High Pressure Control6y, Frostat5 <strong>an</strong>dCr<strong>an</strong>kcase Heater6 ................................................... 724 Smoke Detector7yNo Smoke Detector ........................................................ 0Return Air Smoke Detector 89 ...................................... ASupply Air Smoke Detector .............................................. BSupply <strong>an</strong>d Return Air Smoke Detectors 89 .................. C25 Monitoring ControlsyNo Monitoring Control0 .................................................. 0Clogged Filter Switch0 ................................................... 1F<strong>an</strong> Failure Switch0 ....................................................... 2Discharge Air Sensing Tube0 ......................................... 3Clogged Filter Switch <strong>an</strong>d F<strong>an</strong> Fail Switch0 .................... 4Clogged Filter Switch <strong>an</strong>d DischargeAir Sensing Tube0 ...................................................... 5F<strong>an</strong> Fail Switch <strong>an</strong>d Discharge Air Sensing Tube0 .......... 6Clogged Filter <strong>an</strong>d F<strong>an</strong> Fail Switches<strong>an</strong>d Discharge Air Sensing Tube0 ............................... 7Novar Return Air Sensorq .............................................. 8order the return air smoke detectors when using this type of accessory.9 Return Air Smoke Detector c<strong>an</strong>not be ordered with Novar Controls.0 These options are st<strong>an</strong>dard when ordering Novar Controls.q This options for use when ordering Novar Control only.w The m<strong>an</strong>ual outside air damper will ship factory supplied within the unit, but must be field installed.e Requires Selection of 2" Pleated Filters (Option B or C) for Digit 16.r Through the base electric required when ordering disconnect/circuit breaker options.t Phase Monitor is st<strong>an</strong>dard on T/Y/WSC060A3,4,W models. All other models Phase Monitor will be <strong>an</strong> option.y Not available with electro-mech<strong>an</strong>ical unit controls.kW Nominal No.Rating Digit BTUH Stages Used With460/3/606.0 (B) 20,500 1 T*C036-060A412.0 (E) 41,000 2 T*C036-060A417.6 (G) 59,400 2 T*C036-060A423.0 (J) 78,500 2 T*C060A49.0 (C) 30,700 1 T*C072-102A418.0 (G) 61,400 1 T*C072-120A427.0 (K) 92,100 2 T*C072-120A436.0 (N) 122,900 2 T*C072-120A454.0 (P) 184,300 2 T*C120A4575/3/606.0 (B) 20,500 1 T*C036-060AW12.0 (E) 41,000 2 T*C036-060AW17.6 (G) 59,400 2 T*C036-060AW23.0 (J) 78,500 2 T*C060AW9.0 (C) 30,700 1 T*C072-102AW18.0 (G) 61,400 1 T*C072-120AW27.0 (K) 92,100 2 T*C072-120AW36.0 (N) 122,900 2 T*C072-120AW54.0 (P) 184,300 2 T*C120AWPC-29 Effective 1/1/06


Precedent Packaged CoolingConvertible 3-10 TonsTable PC-30-A — Accessory Electric Heaters – Unit with heater is single circuit / single point power entryModel Power kW Nominal No.Number Supply Rating BTUH Stages Used With1BAYHTRR105A 208/240/1/60 3.8/5.0 12,800/17,100 1 T*C036-060(A or E)1BAYHTRR110A 208/240/1/60 7.5/10.0 25,600/34,100 2 T*C036-060(A or E)1BAYHTRR114A 208/240/1/60 10.4/13.8 35,300/47,100 2 T*C036-060(A or E)1BAYHTRR118A 208/240/1/60 13.2/17.6 45,100/60,100 2 T*C048-060(A or E)1BAYHTRR306A 208/240/3/60 4.5/6.0 13,400/20,500 1 T*C036-060(A or E)3BAYHTRR312A 208/240/3/60 9.0/12.0 30,800/41,000 2 T*C036-060(A or E)3BAYHTRR318A 208/240/3/60 13.1/17.4 44,600/59,400 2 T*C036-060(A or E)3BAYHTRR323A 208/240/3/60 17.3/23.0 58,900/78,500 2 T*C060(A or E)3BAYHTRS309A 208/240/3/60 6.75/9.0 23,000/30,700 1 T*C072A3,TSC090,092A3BAYHTRS318A 208/240/3/60 13.5/18.0 46,100/61,400 1 T*C072A3,TSC090,092A3BAYHTRS327A 208/240/3/60 20.3/27.0 69,000/92,100 2 T*C072A3,TSC090,092A3BAYHTRS336A 208/240/3/60 27.0/36.0 92,200/122,900 2 T*C072A3,TSC090,092A3BAYHTRT309A 208/240/3/60 6.75/9.0 23,000/30,700 1 THC092A3,T*C102A3BAYHTRT318A 208/240/3/60 13.5/18.0 46,100/61,400 1 THC092A3,T*C102,120A3BAYHTRT327A 208/240/3/60 20.3/27.0 69,000/92,100 2 T*C102,120A3,THC092ABAYHTRT336A 208/240/3/60 27.0/36.0 92,200/122,900 2 THC092A3,T*C102,120A3BAYHTRT354A 208/240/3/60 40.5/54.0 138,200/184,300 2 T*C120A3BAYHTRR406A 460/3/60 6.0 20,500 1 T*C036-060(A or E)4BAYHTRR412A 460/3/60 12.0 41,000 2 T*C036-060(A or E)4BAYHTRR418A 460/3/60 17.4 59,400 2 T*C036-060(A or E)4BAYHTRR423A 460/3/60 23.0 78,500 2 T*C060(A or E)4BAYHTRS409A 460/3/60 9.0 30,700 1 T*C072A4,TSC090,092A4BAYHTRS418A 460/3/60 18.0 61,400 1 T*C072A4,TSC090,092A4BAYHTRS427A 460/3/60 27.0 92,100 2 T*C072A4,TSC090,092A4BAYHTRS436A 460/3/60 36.0 122,900 2 T*C072A4,TSC090,092A4BAYHTRT409A 460/3/60 9.0 30,700 1 THC092A4,T*C102A4BAYHTRT418A 460/3/60 18.0 61,400 1 THC092A4,T*C102,120A4BAYHTRT427A 460/3/60 27.0 92,100 2 THC092A4,T*C102,120A4BAYHTRT436A 460/3/60 36.0 122,900 2 THC092A4,T*C102-120A4BAYHTRT454A 460/3/60 54.0 184,300 2 T*C120A4BAYHTRRW06A 575/3/60 6.0 20,500 1 T*C036-060(A or E)WBAYHTRRW12A 575/3/60 12.0 41,000 2 T*C036-060(A or E)WBAYHTRRW18A 575/3/60 17.4 59,400 2 T*C036-060(A or E)WBAYHTRRW23A 575/3/60 23.0 78,500 2 T*C060(A or E)WBAYHTRSW09A 575/3/60 9.0 30,700 1 T*C072AW,TSC090,092AWBAYHTRSW18A 575/3/60 18.0 61,400 1 T*C072AW,TSC090,092AWBAYHTRSW27A 575/3/60 27.0 92,100 2 T*C072AW,TSC090,092AWBAYHTRSW36A 575/3/60 36.0 122,900 2 T*C072AW,TSC090,092AWBAYHTRTW18A 575/3/60 18.0 61,400 1 THC092AW,T*C102,120AWBAYHTRTW27A 575/3/60 27.0 92,100 2 THC092AW,T*C102,120AWBAYHTRTW36A 575/3/60 60 122,900 2 THC092AW,T*C102,120AWBAYHTRTW54A 575/3/60 54.0 184,300 2 T*C120AW1 A=R-22, E=410A.Effective 1/1/06PC-30For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Precedent Packaged CoolingConvertible 3-10 TonsTable PC-31-A — AccessoriesModel Number Description Used WithuBAYABRD001C .............. ReliaTel Options Module .................................................... See Note8BAYASCT0010r* .......... Anti-Short-Cycle Timer .......................................................... T*C036-060(A or E)_EBAYBARM010A6 ........... Barometric Relief ................................................................... T*C036-060(A or E)BAYBARM011A6 ........... Barometric Relief ................................................................... T*C072-120ABAYCCHT010B ............... Cr<strong>an</strong>kcase Heater .................................................................. THC072A3, TSC048-060(A or E)1,A3, T*C072-120A3BAYCCHT011B ............... Cr<strong>an</strong>kcase Heater .................................................................. THC072A4,AW, TSC048-060(A or E)4,AW,T*C072-120A4,AWBAYCCHT012A .............. Cr<strong>an</strong>kcase Heater .................................................................. T*C090A3BAYCCHT013A .............. Cr<strong>an</strong>kcase Heater .................................................................. T*C090A4BAYCCHT014A ............... Cr<strong>an</strong>kcase Heater .................................................................. T*C090AWBAYCO2K001B5t ......... CO 2 Sensor Kit, Wall Mounted ............................................... T*C036-060(A or E)_R, T*C072-120A_R w/EconomizerBAYCO2K003B5t ......... CO 2 Sensor Kit, Duct Mounted .............................................. T*C036-060(A or E)_R, T*C072-120A_R w/EconomizerBAYCURB042A4 ........... Roof Curb .............................................................................. T*C036-060(A or E)BAYCURB043A4 ........... Roof Curb .............................................................................. T*C072-120ABAYDFPS003A58 ......... Clogged Filter Switch ............................................................. T*C036-060(A or E), T*C072-120A_RBAYDFPS004A58 ......... F<strong>an</strong> Failure Switch ................................................................. T*C036-060(A or E), T*C072-120A_RBAYDMPR051A5 ........... 0-50% Motorized Outside Air Damper ................................... T*C036-060(A or E)_RBAYDMPR052A0 ........... 0-50% Motorized Outside Air Damper ................................... T*C036-060(A or E)_EBAYDMPR053By ........... 0-50% M<strong>an</strong>ual Outside Air Damper ....................................... T*C036-060(A or E)BAYDMPR054A5 ........... 0-50% Motorized Outside Air Damper ................................... T*C072-120A_RBAYDMPR055A0 ........... 0-50% Motorized Outside Air Damper ................................... T*C072-120A_EBAYDMPR056By ........... 0-50% M<strong>an</strong>ual Outside Air Damper ....................................... T*C072-120ABAYECON085A5 ........... 0-100% Dry Bulb Economizer without Barometric Relief ...... T*C036-060(A or E)_RBAYECON086A0 ........... 0-100% Dry Bulb Economizer without Barometric Relief ...... T*C036-060(A or E)_EBAYECON087A5 ........... 0-100% Dry Bulb Economizer without Barometric Relief ..... T*C072-120A_RBAYECON088A0 ........... 0-100% Dry Bulb Economizer without Barometric Relief ..... T*C072-120A_EBAYENTH005A15 ......... Reference Enthalpy Kit .......................................................... BAYECON085A, 087ABAYENTH006A15 ......... Comparative Enthalpy Kit ...................................................... BAYECON085A, 087ABAYENTH001A ............... Enthalpy Control (Solid State) ............................................... BAYECON0086A, 088ABAYFRST001A50 ......... High Temperature Stat .......................................................... T*C036-060(A or E), T*C072-120A_RBAYGARD036B .............. Condenser Coil Hail Guard .................................................... TSC036-060(A or E), THC036,048(A or E)BAYGARD037B .............. Condenser Coil Hail Guard .................................................... THC060(A or E)BAYGARD040B .............. Condenser Coil Hail Guard .................................................... THC072, 090BAYGARD041B .............. Condenser Coil Hail Guard .................................................... TSC102,120A, THC092,102,120ABAYHSDR012A .............. High Static Drive Kit ............................................................... T*C072A, TSC090,092ABAYHSMT073A .............. .45 HP Oversized motor kit .................................................... T*C036(A or E)1,(A or E)3BAYHSMT074A .............. .45 HP Oversized motor kit .................................................... T*C036(A or E)4BAYHSMT075A .............. .45 HP Oversized motor kit .................................................... T*C036(A or E)WBAYHSMT076A .............. .75 HP Oversized motor kit .................................................... T*C048(A or E)1,(A or E)3BAYHSMT077A .............. .75 HP Oversized motor kit .................................................... T*C048(A or E)4BAYHSMT078A .............. .75 HP Oversized motor kit .................................................... T*C048(A or E)WBAYHSMT079A .............. 1.2 HP Oversized motor kit .................................................... T*C060(A or E)1,(A or E)3BAYHSMT080A .............. 1.2 HP Oversized motor kit .................................................... T*C060(A or E)4BAYHSMT081A .............. 1.2 HP Oversized motor kit .................................................... T*C060(A or E)WBAYHSMT082A .............. 2 HP Oversized motor kit ....................................................... T*C072A3, A4BAYHSMT083A .............. 2 HP Oversized motor kit ....................................................... T*C072AWBAYHSMT084A .............. 3 HP Oversized motor kit ....................................................... T*C090, 092A3, A4BAYHSMT085A .............. 3 HP Oversized motor kit ....................................................... T*C090, 092AWBAYHSMT086A .............. 3 HP Oversized motor kit ....................................................... T*C102A3,A4, THC092A3,A4BAYHSMT087A .............. 3 HP Oversized motor kit ....................................................... T*C102AW, THC092AWBAYHSMT088A .............. 5 HP Oversized motor kit ....................................................... T*C120A3, A4BAYHSMT089A .............. 5 HP Oversized motor kit ....................................................... T*C120AWBAYICSI003A5e ............ <strong>Tr<strong>an</strong>e</strong> Communications Interface (TCI) .................................. T*C036-060(A or E), T*C072-120A_RBAYKSKT255A ............... Quick Start Kit ........................................................................ THC060A1, TSC048-060A1BAYKSKT256A ............... Quick Start Kit ........................................................................ TSC036(A or E)1BAYLOAM020B258 ..... Evaporator Defrost Control (Frostat) ...................................... T*C036-060(A or E), T*C072-120A_RBAYLTCI002B5 .............. LonTalk ® Communications Interface (LCI) ............................. T*C036-060(A or E), T*C072-120A_RBAYPWRX026Aq ........... Power Exhaust ...................................................................... T*072-120A3BAYPWRX027Aq ........... Power Exhaust ...................................................................... T*072-120A4BAYPWRX028Aq ........... Power Exhaust ...................................................................... T*072-120AWBAYQACB009A49 ........ Quick Adapt Roof Curb .......................................................... T*C036-060(A or E)BAYQACB010A49 ........ Quick Adapt Roof Curb .......................................................... T*C036-060(A or E)BAYQACB011A4w ........ Quick Adapt Roof Curb .......................................................... T*C072-120ABAYQACB012A4w ........ Quick Adapt Roof Curb .......................................................... T*C072-120ABAYQACB013A4w ........ Quick Adapt Roof Curb .......................................................... T*C072-120ABAYSTAT0235 ............... Remote Potentiometer ........................................................... BAYECON085A, 087ABAYSERV001A5 ............ Selective Resist<strong>an</strong>ce Service Tester ..................................... T*C036-060(A or E), T*C072-120A_RBAYSENS016A5 ............ Temperature Sensor .............................................................. T*C036-060(A or E)_RBAYTUBE005A358 ...... Discharge Air Sensing Kit ...................................................... T*C036-060(A or E)_RBAYTUBE007A358 ....... Discharge Air Sensing Kit ...................................................... T*C072-120_RBAYVNOR001B58t ..... Ventilation Override Kit w/ReliaTel options module ............ T*C036-060(A or E), T*C072-120A_R1 Kits contain all necessary parts to achieve desired level ofenthalpy control.2 For ReliaTel microprocessor controlled units only.Must be factory installed for electromech<strong>an</strong>ical controlledunits3 Used for true discharge air sensing in both heating <strong>an</strong>dcooling.Required for supply air tempering.4 Lynn Haven M<strong>an</strong>ufacturing has a No-Return policy for thisroof curb.5 For use with ReliaTel controlled units only6 Barometric Relief accessory installs in ductwork for horizontalconfiguration. For downflow configuration, installs in the unit'shorizontal return duct. See Installer's Guide for completeinstructions.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.7 C<strong>an</strong>not be used in conjunction with factory installed0 For use with electromech<strong>an</strong>ical controlled units only.smoke detector.q C<strong>an</strong>not be used in conjunction with Barometric Relief.8 BAYABRD001C is required when ordering field installed Order Economizer without Barometric Relief.accessories Clogged Filter Switch (BAYDFPS003A), F<strong>an</strong> w BAYQACB012A adapts Voyager BAYCURB025A toFail Switch (BAYDFPS004A), Discharge Air Sensing Kit accept Precedent 6-10 ton unit. BAYQACB013A adapts(BAYTUBE004A) or Evaporator Defrost Control (Frostat) Voyager BAYCURB026A to accept Precedent 6-10 ton(BAYLOAM020B) Ventilation Override Kitunit. BAYQACB011A adapts Voyager BAYCURB022 to(BAYVNOR001B) unless the following options are factory accept Precedent 6-10 ton unit.installed: Frostat, Smoke Detector, Clogged Filter Switch, e Interface allows a unit with ReliaTel Controls toF<strong>an</strong> Failure Switch, Discharge Air Sensing Kit. Thesecommunicate with Tracer 100, Tracker, VariTrac II, <strong>an</strong>d isfactory installed options include the ReliaTel Options the preferred method of communication to Tracer Summit.Module.r Activated on Power On.9 BAYQACB009A adapts Voyager BAYCURB021B to t Field installed accessory requires economizer.accept Precedent 3-5 ton unit. BAYQACB010A adapts y The m<strong>an</strong>ual outside air damper will ship factory suppliedVoyager BAYCURB022B to accept Precedent unit.within the unit, but must be field installed.u A=R-22, E=410A.* Either St<strong>an</strong>dard or High Efficiency.PC-31 Effective 1/1/06


Precedent Packaged CoolingConvertible 3-10 TonsTable PC-32-A — Zone Sensors for ReliaTel Controlled UnitsModelNumber Description Used WithBAYMTPL003B Retrofit Wall Cover Plate Kit 7.25" x 6.0" BAYSENS019CBAYMTPL004B Retrofit Wall Cover Plate Kit 4.75" x 4.75" BAYSENS006,008010B,013,014C,017BBAYSENS006B Single Setpoint M<strong>an</strong>ual Ch<strong>an</strong>geover T*C036-060_RBAYSENS008B Dual Setpoint M<strong>an</strong>ual or Auto Ch<strong>an</strong>geover T*C036-060_RBAYSENS010B Dual Setpoint M<strong>an</strong>. or Auto Ch<strong>an</strong>geover with SystemFunction LightsT*C036-120_RBAYSENS019C Programmable Night Setback w/System Function Lights T*C036-120_RBAYSENS013C1 Room Sensor w/ Override <strong>an</strong>d C<strong>an</strong>cel Buttons T*C036-120_RBAYSENS014C1 Room Sensor w/ Temp. Adjustment with Override <strong>an</strong>dC<strong>an</strong>cel ButtonsT*C036-120_RBAYSENS017B Remote Room Sensor BAYSENS006B,008B,010B, & 019CBAYSENS032A8 Dual Thermistor Remote Zone Sensor T*C036-120A_RBAYSENS035A8 Digital Display Zone Sensor T*C036-120A_RBAYSENS036A7 Wall-Mounted Humidity Zone Sensor THC120A,3,4,WRBAYSENS037A7 Duct-Mounted Humidity Zone Sensor THC120A,3,4,WRTable PC-32-B — ThermostatsModelNumber Description Used WithBAY24X042 DPDT F<strong>an</strong> <strong>an</strong>d Electric Heat Relay BAYSTAT008,010BAY28X1904 Locking Thermostat Cover for up to 4 units Room ThermostatsBAYSTAT040B2 Programmable Thermostat T*C036-120ABAYBASE008A Subbase 1-Stage Heating/Cooling BAYSTAT040BBAYBASE006A Subbase 2-Stage Heating/Cooling BAYSTAT040BBAYSENS033A Remote Wall Sensor BAYSTAT040BBAYSENS034A Remote Duct Sensor BAYSTAT040BBAYSTAT0083 M<strong>an</strong>ual 1-Stage Heating/Cooling T*C036-120ABAYSTAT0103 Auto 2-Stage Heating/Cooling T*C036-120ATCONT200AN11AA Electronic 1 Htg/1 Clg (Non Prog) T*C036-090A1 Used with Integrated Comfort TM Systems, <strong>an</strong>y unit type. These sensors do not work with TCM. Consult BASD Marketing for them.2 Requires use of BAYBASE006A or BAYBASE008A.3 Requires DPDT F<strong>an</strong> <strong>an</strong>d Electric Heat Relay BAY24x042 when using electric heat.4 Do not use with programmable thermostats.5 Specially designed for electric heat applications (inst<strong>an</strong>t on f<strong>an</strong>).6 Use only with electromech<strong>an</strong>ical unit controls.7 For use with Dehumidification (Hot Gas Reheat) Coil Option.8 For use with ReliaTel Controls only.*Either st<strong>an</strong>dard or high efficiency modelsEffective 1/1/06PC-32For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Light Commercial Packaged CoolingNew Model Reference ChartTable PC-33-A — Quick ReferencePrecedentPrecedentVoyager Horizontal Voyager Downflow Controls Ordering Number Service Model NumberTCD036C100B Micro-Proc TSC036*1R0A0000 TSC036*1R0A**000000000000Electro-Mech TSC036*1E0A0000 TSC036*1E0A**000000000000TCD036C300B Micro-Proc TSC036*3R0A0000 TSC036*3R0A**000000000000Electro-Mech TSC036*3E0A0000 TSC036*3E0A**000000000000TCD036C400B Micro-Proc TSC036*4R0A0000 TSC036*4R0A**000000000000Electro-Mech TSC036*4E0A0000 TSC036*4E0A**000000000000TCH048C100B TCD048C100B Micro-Proc TSC048*1R0A0000 TSC048*1R0A**000000000000Electro-Mech TSC048*1E0A0000 TSC048*1E0A**000000000000TCH048C300B TCD048C300B Micro-Proc TSC048*3R0A0000 TSC048*3R0A**000000000000Electro-Mech TSC048*3E0A0000 TSC048*3E0A**000000000000TCH048C400B TCD048C300B Micro-Proc TSC048*4R0A0000 TSC048*4R0A**000000000000Electro-Mech TSC048*4E0A0000 TSC048*4E0A**000000000000TCH048CW00B TCD048CW00B Micro-Proc TSC048*WR0A0000 TSC048*WR0A**000000000000Electro-Mech TSC048*WE0A0000 TSC048*WE0A**000000000000TCH060C100B TCD060C100B Micro-Proc TSC060*1R0A0000 TSC060*1R0A**000000000000Electro-Mech TSC060*1E0A0000 TSC060*1E0A**000000000000TCH060C300B TCD060C300B Micro-Proc TSC060*3R0A0000 TSC060*3R0A**000000000000Electro-Mech TSC060*3E0A0000 TSC060*3E0A**000000000000TCH060C400B TCD060C400B Micro-Proc TSC060*4R0A0000 TSC060*4R0A**000000000000Electro-Mech TSC060*4E0A0000 TSC060*4E0A**000000000000TCH060CW00B TCD060CW00B Micro-Proc TSC060*WR0A0000 TSC060*WR0A**000000000000Electro-Mech TSC060*WE0A0000 TSC060*WE0A**000000000000*Digit 7- A=R-22, E=410A.NOTE: N/A indicates that <strong>an</strong> Ordering Number has not yet been set up for the indicated model.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-33 Effective 1/1/06


Light Commercial Packaged CoolingNew Model Reference ChartTable PC-34-A — Quick ReferencePrecedentPrecedentVoyager Horizontal Voyager Downflow Controls Ordering Number Service Model NumberTCH074C300B TCD074C300B Micro-Proc TSC072A3R0A0000 TSC072A3R0A**000000000000Electro-Mech TSC072A3E0A0000 TSC072A3E0A**000000000000TCH074C400B TCD074C400B Micro-Proc TSC072A4R0A0000 TSC072A4R0A**000000000000Electro-Mech TSC072A4E0A0000 TSC072A4E0A**000000000000W 575 Volt Micro-Proc TSC072AWR0A0000 TSC072AWR0A**000000000000Electro-Mech TSC072AWE0A0000 TSC072AWE0A**000000000000TCH075C300B TCD075C300B Micro-Proc THC072A3R0A0000 THC072A3R0A**000000000000Electro-Mech THC072A3E0A0000 THC072A3E0A**000000000000TCH075C400B TCD075C400B Micro-Proc THC072A4R0A0000 THC072A4R0A**000000000000Electro-Mech THC072A4E0A0000 THC072A4E0A**000000000000TCH075CW00B TCD075CW00B Micro-Proc THC072AWR0A0000 THC072AWR0A**000000000000Electro-Mech THC072AWE0A0000 THC072AWE0A**000000000000TCH090D300B TCD090D300B Micro-Proc TSC090A3R0A0000 TSC090A3R0A**000000000000Electro-Mech TSC090A3E0A0000 TSC090A3E0A**000000000000TCH090D400B TCD090D400B Micro-Proc TSC090A4R0A0000 TSC090A4R0A**000000000000Electro-Mech TSC090A4E0A0000 TSC090A4E0A**000000000000TCH090DW00B TCD090DW00B Micro-Proc TSC090AWR0A0000 TSC090AWR0A**000000000000Electro-Mech TSC090AWE0A0000 TSC090AWE0A**000000000000TCH091D300B TCD091D300B Micro-Proc THC090A3R0A**000000000000Electro-MechTHC090A3E0A**000000000000TCH091D400B TCD091D400B Micro-Proc THC090A4R0A**000000000000Electro-MechTHC090A4E0A**000000000000W 575 Volt Micro-Proc THC090AWR0A**000000000000Electro-MechTHC090AWE0A**000000000000TCH102C300A TCD102C300A Micro-Proc TSC102A3R0A0000 TSC102A3R0A**000000000000Electro-Mech TSC102A3E0A0000 TSC102A3E0A**000000000000TCH102C400A TCD102C400A Micro-Proc TSC102A4R0A0000 TSC102A4R0A**000000000000Electro-Mech TSC102A4E0A0000 TSC102A4E0A**000000000000TCH102CW00A TCD102CW00A Micro-Proc TSC102AWR0A0000 TSC102AWR0A**000000000000Electro-Mech TSC102AWE0A0000 TSC102AWE0A**000000000000TCH103C300A TCD103C300A Micro-Proc THC102A3R0A0000 THC102A3R0A**000000000000Electro-Mech THC102A3E0A0000 THC102A3E0A**000000000000TCH103C400A TCD103C400A Micro-Proc THC102A4R0A0000 THC102A4R0A**000000000000Electro-Mech THC102A4E0A0000 THC102A4E0A**000000000000TCH103CW00A TCD103CW00A Micro-Proc THC102AWR0A0000 THC102AWR0A**000000000000Electro-Mech THC102AWE0A0000 THC102AWE0A**000000000000TCH120C300A TCD120C300A Micro-Proc TSC120A3R0A0000 TSC120A3R0A**000000000000Electro-Mech TSC120A3E0A0000 TSC120A3E0A**000000000000TCH120C400A TCD120C400A Micro-Proc TSC120A4R0A0000 TSC120A4R0A**000000000000Electro-Mech TSC120A4E0A0000 TSC120A4E0A**000000000000TCH120CW00A TCD120CW00A Micro-Proc TSC120AWR0A0000 TSC120AWR0A**000000000000Electro-Mech TSC120AWE0A0000 TSC120AWE0A**000000000000TCH121C300A TCD121C300A Micro-Proc THC120A3R0A0000 THC120A3R0A**000000000000Electro-Mech THC120A3E0A0000 THC120A3E0A**000000000000TCH121C400A TCD121C400A Micro-Proc THC120A4R0A0000 THC120A4R0A**000000000000Electro-Mech THC120A4E0A0000 THC120A4E0A**000000000000TCH121CW00A TCD121CW00A Micro-Proc THC120AWR0A0000 THC120AWR0A**000000000000Electro-Mech THC120AWE0A0000 THC120AWE0A**000000000000NOTE: N/A indicates that <strong>an</strong> Ordering Number has not yet been set up for the indicated model.Effective 1/1/06PC-34For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


ReliaTel Controls for Precedent,Precedent 13 SEER <strong>an</strong>d VoyagerPackaged Unit Protection/Operation Timings <strong>an</strong>d FeaturesAlternating Lead/Lag – Dual Compressor Models Only —During periods of part load operation, each compressor cyclesalternately as circuit number one, equalizing compressor wear <strong>an</strong>d runtime. Enabled by cutting the wire (BLUE) at (RTRM) junction numberJ3-8. St<strong>an</strong>dardAnti Short Cycle Timer (ASCT) Function — Provides a three (3)minute minimum “ON” time <strong>an</strong>d a three (3) minute minimum “OFF” timefor compressors, enh<strong>an</strong>ces compressor reliability by ensuring proper oilreturn. St<strong>an</strong>dardBuilt In Evaporator Defrost Control (EDC) Function —Provides low ambient cooling down to 0°F. St<strong>an</strong>dardBuilt In F<strong>an</strong> Delay Relay (FDR) Function — Provides custom indoorf<strong>an</strong> timing sequences for the different types of equipment, enh<strong>an</strong>cingefficiency <strong>an</strong>d reliability. St<strong>an</strong>dardBuilt In Night Set Back <strong>an</strong>d Unoccupied Functions1 — When usinga st<strong>an</strong>dard dual setpoint/auto ch<strong>an</strong>ge over Zone Sensor Module (ZSM),this function is enabled by applying a short across terminal J6-11 <strong>an</strong>dJ6-12. Sets cooling setpoint up a minimum of 7°F, sets heating setpointback a minimum of 7°F, forces outside air damper (if present) minimumposition to zero, <strong>an</strong>d forces f<strong>an</strong> operation to automatic. Accessory(requires time clock accessory or field supplied/installed switch orcontacts).Built In “TEST” Mode — Aids in quick verification of system<strong>an</strong>d control operation, exercises both hardware <strong>an</strong>d software(no special tools required). St<strong>an</strong>dardBuilt In Unoccupied Mode1 — When using a st<strong>an</strong>dard singlesetpoint/m<strong>an</strong>ual ch<strong>an</strong>ge over Zone Sensor Module (ZSM), this functionis enabled by applying a short across terminal J6-11 <strong>an</strong>d J6-12. Forcesoutside air damper (if present) minimum position to zero, forces f<strong>an</strong>operation to automatic. Accessory (requires time clock accessory orfield supplied/installed switch or contacts.)Direct Digital Control (DDC)1 — Proportional Integral (PI) control.Proportional – sets corrective action proportional to deviationfrom setpoint. Integral – fine tunes the rate of corrective actionproportional to the error (results in superior space temperature control).St<strong>an</strong>dardEconomizer Preferred Cooling1 — Provides fully integratedoperation if required. Will not turn on a compressor with the economizer,if the space is recovering adequately with the economizer alone (0.2°F/minute). Allows the equipment to be utilized in more varied applications.St<strong>an</strong>dard with economizer accessory.Emergency Stop Terminals On Low Voltage Terminal Board(LTB-5 <strong>an</strong>d LTB-6) — Provides a convenient point to disable theequipment completely, <strong>an</strong>d immediately. Still provides communication toBAS. St<strong>an</strong>dardHeat Pump Smart Recovery <strong>an</strong>d Smart Staging1 — Inhibitsauxiliary heat operation if the space is recovering adequately(0.1°F/minute) with the heat pump alone, providing considerablesavings in operating costs. St<strong>an</strong>dardHeat Pump Soft Start — Provides a smooth tr<strong>an</strong>sition into heatingafter defrost, minimizing noise <strong>an</strong>d compressor stress associated withswitch over. St<strong>an</strong>dardIncreased Reliability — Fewer components (moving electromech<strong>an</strong>icalparts), less likelihood of equipment down time orfailure. St<strong>an</strong>dardIntegral Electric Heat Staging1 — Stages electric heaters “OFF”<strong>an</strong>d “ON”, eliminating the use of outdated sequencers. St<strong>an</strong>dardIntelligent Fallback1 — A built in Default Control provides adaptiveoperation, which allows the equipment to continueto operate, providing comfort in the event of certain componentfailures. Also, allows emergency operation without a Zone SensorModule (ZSM). St<strong>an</strong>dardLow Ambient Start Timer (LAST) Function — Bypasses lowpressure control when a compressor starts, eliminating nuis<strong>an</strong>cecompressor lock outs. St<strong>an</strong>dardLower Installation Cost — Using a st<strong>an</strong>dard Zone Sensor Module(ZSM), control voltage wiring may be run up to five (5) times furtherth<strong>an</strong> <strong>an</strong>y electromech<strong>an</strong>ical system, with no increase in wire gauge.Example: Electromech<strong>an</strong>ical System –30 feet maximum using 22 gauge wire. Micro Control System – 150feet using 22 gauge wire. St<strong>an</strong>dardOn Board Diagnostics1 — Assist with equipment troubleshooting, ifa problem occurrence should take place. St<strong>an</strong>dardRemote Sensing1 — All st<strong>an</strong>dard Zone Sensor Modules(ZSMs) have remote sensing capabilities, typically achieved by using<strong>an</strong> expensive program-mable thermostat <strong>an</strong>d remote sensor withelectromech<strong>an</strong>ical equipment. Accessory (requires use of remotesensor).Selectable Economizer Dry Bulb Ch<strong>an</strong>ge Over — Allows thecapability of selecting the following dry bulb ch<strong>an</strong>ge over points:63, 67, 70 or 73°F. St<strong>an</strong>dard with economizer accessory.Space Temperature Averaging1 — All st<strong>an</strong>dard Zone SensorModules (ZSMs) have space temperature averaging capabilities,typically achieved by using <strong>an</strong> expensive programmable thermostat<strong>an</strong>d minimum of four (4) remote sensors with electromech<strong>an</strong>icalequipment. Averaging with ReliaTel c<strong>an</strong> be achieved with two(2) sensors.Supply Air Tempering1 — A built in feature, once enabled onlythrough <strong>an</strong> ICS device, may also be enabled using a digital orprogrammable Zone Sensor Module. When in the HEAT mode(<strong>an</strong>d not actively heating), if supply air temperature drops 10°F belowthe heating setpoint, heat is turned on until supply air temperaturerises to a point 10°F above the heating setpoint. Provides temperateair during the “OFF” cycle, <strong>an</strong>d eliminatescold air dumping from supply ducts. Extremely effective whenintroducing <strong>an</strong>y qu<strong>an</strong>tity of fresh air. St<strong>an</strong>dard when using a RTOM,ICS device, digital, or programmable Zone Sensor Module.Time Delay Relay (TDR) Function — Provides <strong>an</strong> incrementalstaging delay between compressors, minimizes equipment currentinrush <strong>an</strong>d consumption by keeping compressors from startingsimult<strong>an</strong>eously. St<strong>an</strong>dardLow Pressure <strong>an</strong>d High Pressure Compressor Lockout — 3 tripswill lockout control.1 Denotes features lost from utilizing st<strong>an</strong>dard conventional stat.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-35 Effective 1/1/06


Micro Control for Precedent,Precedent 13 SEER <strong>an</strong>d VoyagerOperation With A ThermostatWhen the ReliaTel RTRM Thermostat Interface is used, equipment operationdiffers signific<strong>an</strong>tly. The basic equipment protection features remain intact, <strong>an</strong>d thefollowing features <strong>an</strong>d benefits are lost:• Direct Digital Control (DDC) –Proportional Integral (PI) control islost, equipment is controlled by athermostat or generic buildingautomation system device.• Intelligent Fall back is lost, if a failureoccurs in the device controlling theequipment, operation will cease.• Installation is more costly, with theaddition of a thermostat or genericcontrol, the control wiring size must beincreased.• Heat Pump Smart Recovery <strong>an</strong>dSmart Staging is lost, Heat Pumpoperation becomes more costly unlessgeneric control being applied c<strong>an</strong>accomplish this.• Remote Sensing capabilities are lost,unless generic control being appliedc<strong>an</strong> accomplish this.• Low ambient disabled economizer <strong>an</strong>dsecond condensing f<strong>an</strong> cyclingcapability.• Space Temperature Averagingcapabilities are lost, unless genericcontrol being applied c<strong>an</strong> accomplishthis.• Supply Air Tempering feature is lost,discharge air temperature may be coldwhen not actively heating if outdoor airis being introduced through theequipment.• Built In Night Set Back <strong>an</strong>d Unoccupiedfunctions are lost, unless genericcontrol being applied c<strong>an</strong> accomplishthis.• Built In Unoccupied Mode is lost,unless generic control being appliedc<strong>an</strong> accomplish this.• Economizer Preferred Cooling Featureis lost, all compressor operation islocked out below 50°F.Effective 1/1/06PC-36For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Precedent 3-5 ton 13 SEER R-22Packaged CoolingFeaturingA New Look for a New CenturyBeveled TopSmoother DesignSmall compact cabinetRecessed access h<strong>an</strong>dlesSt<strong>an</strong>dard Features:• <strong>Tr<strong>an</strong>e</strong> built scroll compressors on all 3-5 ton units• Colored <strong>an</strong>d numbered wiring• Provisions for through the Base Condensate Drain Connections• Patented Hybrid Condenser Coil for easy cle<strong>an</strong>ing• 1" throwaway filters provided on 3-5 ton units• Liquid Line Refriger<strong>an</strong>t Drier• Operating Charge of R-22• IAQ Sloped Drain P<strong>an</strong>s• Single point power for Electric Heat• Low Ambient to 40°F on Electromech<strong>an</strong>ical models• Low Ambient to 0°F on Microprocessor models• 5 - year Limited Compressor Warr<strong>an</strong>ty• 1 - year Limited Parts Warr<strong>an</strong>tyAdded Flexibility• Electromech<strong>an</strong>ical or ReliaTel controls (See page PC-35 for ReliaTelControl Information)• Convertible airflow (ships in downflow application)• Fork lift openings on three sides of unit• Belt drive - st<strong>an</strong>dard or oversized motors• We don’t prepackage options• Choose options tailored to suit each job —pay only for what is needed• Units ship with options installed —<strong>an</strong>d within our st<strong>an</strong>dard ship cycle timeFactory Installed Options• Through-the-Base — Electrical• Convenience Outlet — Powered or unpowered• Unit Disconnect Switch• Smoke Detectors — Supply, return, or both• Condenser Coil Coating• Hinged Access Service P<strong>an</strong>els• Discharge Air Sensor• F<strong>an</strong> Fail <strong>an</strong>d Clogged Filter Switches• Condenser Coil Guard — Hail Protection Quality• TXV thermal exp<strong>an</strong>sion valve <strong>an</strong>d split face evaporator coil st<strong>an</strong>dard• Dehumidification Hot Gas Reheat Coil• Novar Controls• TCI (<strong>Tr<strong>an</strong>e</strong> Communication Interface)• LonTalk (Communication Interface)• 2" Pleated Media filters• Phase MonitorThe same <strong>Tr<strong>an</strong>e</strong> Quality <strong>an</strong>dReliability … with added Flexibility!For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-37 Effective 1/1/06


Precedent Packaged CoolingConvertible 3-5 Tons 13 SEER R-22Table PC-38-A — Base Unit — 13 SEER High Efficiency — Electromech<strong>an</strong>icalCooling Cabinet ShippingUnit Perform<strong>an</strong>ce3 Capacity Dimensions (in.) Downflow Downflow Weight Max1Tons Ordering No. SEER/EER (Btuh) H x W x L Supply Return (Ibs.) MCA* Fuse*THC – 208-230/3/60 – Three Phase – No Heat3 THC033A3E0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 19.9 304 THC043A3E0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 22.6 355 THC063A3E0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 28.8 45THC – 460/3/60 – Three Phase – No Heat3 THC033A4E0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 10.4 154 THC043A4E0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 11.8 155 THC063A4E0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 14.3 20THC – 575/3/60 – Three Phase – No Heat3 THC033AWE0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 7.7 154 THC043AWE0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 8.5 155 THC063AWE0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 11.4 15Table PC-38-B — Base Unit — 13 SEER High Efficiency — ReliaTel Microprocessor ControlsCooling Cabinet ShippingUnit Perform<strong>an</strong>ce3 Capacity Dimensions (in.) Downflow Downflow Weight Max1Tons Ordering No. SEER/EER (Btuh) H x W x L Supply Return (Ibs.) MCA* Fuse*THC – 208-230/3/60 – Three Phase – No Heat3 THC033A3R0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 19.9 304 THC043A3R0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 22.6 355 THC063A3R0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 28.8 45THC – 460/3/60 – Three Phase – No Heat3 THC033A4R0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 10.4 154 THC043A4R0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 11.8 155 THC063A4R0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 14.3 20THC – 575/3/60 – Three Phase – No Heat3 THC033AWR0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 7.7 154 THC043AWR0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 8.5 155 THC063AWR0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 11.4 151 HACR breaker per NEC.2 Downflow Airflow/Horizontal Airflow.3 SEER applies, 3-5 tons; EER applies 6-10 tons.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.Effective 1/1/06PC-38For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Precedent PackagedCooling Convertible 3-5 Tons13 SEER R-22 (Model Digit Numbers)Digit Description Order Number1-8 Main Assembly (see previous page)9 Unit ControlsElectro-Mech<strong>an</strong>ical ......................................................... EUnit Controls -ReliaTel Micro-processor ....................... R10 (See Heater Table below)11 Minor Design SequenceFirst Sequence .............................................................. A12-13 Service SequenceFirst Sequence (Factory Supplied) ................................. ✱,✱14 Fresh Air SelectionNo Fresh Air ................................................................... 00-50% M<strong>an</strong>ual Outside Air Damperw .............................. A0-50% Motorized Outside Air Damper .............................. B0-100% Economizer, Dry Bulb withoutBarometric Relief 2 .................................................... C0-100% Economizer, Dry Bulb withBarometric Relief2 .................................................... D0-100% Economizer, Reference Enthalpywithout Barometric Relief12 ....................................... E0-100%Economizer, Reference Enthalpywith Barometric Relief12 ........................................... F0-100%Economizer, Comparative Enthalpywithout Barometric Relief 12 ..................................... G0-100%Economizer, Comparative Enthalpywith Barometric Relief 12 ......................................... H15 Supply F<strong>an</strong>/Drive Type/MotorSt<strong>an</strong>dard Drive ................................................................ 016 Hinged Service Access & FiltersSt<strong>an</strong>dard P<strong>an</strong>els & Filters ................................................ 0Hinged Access P<strong>an</strong>els & St<strong>an</strong>dard Filters ........................ ASt<strong>an</strong>dard P<strong>an</strong>els & 2" Pleated Filters ............................... BHinged Access P<strong>an</strong>els & 2" Pleated Filters ...................... C17 Condenser Coil ProtectionSt<strong>an</strong>dard Coil ................................................................. 0St<strong>an</strong>dard Coil with Hail Guard .......................................... 1Epoxy Coated Condenser Coil ........................................ 2Epoxy Coated Condenser Coil with Hail Guard ................ 318 Through the Base ProvisionsNo Through the Base Provisions ..................................... 0Through the Base Electricr ............................................ A19 Disconnect/Circuit Breaker /Phase Monitor (3 phase only)No Disconnect/ Circuit Breaker/No Phase Monitor ............ 0Non-Fused Disconnectr ................................................ 1Circuit Breakerr ............................................................. 2Digit Description Order NumberPhase Monitort ............................................................. 3Phase Monitort & Non-Fused Disconnect Switch ............ 4Phase Monitort & Circuit Breaker ................................... 520 Convenience OutletNo Convenience Outlet ................................................... 0Unpowered Convenience Outlet ...................................... APowered Convenience Outlet (3 phase only)3 ................ B21 Communications OptionsyNo Communications Interface ......................................... 0<strong>Tr<strong>an</strong>e</strong> Communications Interface ..................................... 1LonTalk ® Communications Interface ................................. 2Novar 2024 Controls ....................................................... 3Novar 3051 Controls ....................................................... 422 Refrigeration System OptionSt<strong>an</strong>dard Refrigeration System withThermal Exp<strong>an</strong>sion Valve .............................................. 0Dehumidification (Hot Gas Reheat Coil)e ........................ B23 Refrigeration ControlsNo Refrigeration Control .................................................. 0High Pressure Control6y .............................................. 1Frostat5 ........................................................................ 2Cr<strong>an</strong>kcase Heater ........................................................... 3High Pressure Control6y <strong>an</strong>d Frostat5 ......................... 4High Pressure Control6y <strong>an</strong>d Cr<strong>an</strong>kcase Heater ............ 5Frostat5 <strong>an</strong>d Cr<strong>an</strong>kcase Heater6 .................................. 6High Pressure Control6y, Frostat5 <strong>an</strong>dCr<strong>an</strong>kcase Heater6 ................................................... 724 Smoke Detector7yNo Smoke Detector ........................................................ 0Return Air Smoke Detector 89 ...................................... ASupply Air Smoke Detector .............................................. BSupply <strong>an</strong>d Return Air Smoke Detectors 89 .................. C25 Monitoring ControlsyNo Monitoring Control0 .................................................. 0Clogged Filter Switch0 ................................................... 1F<strong>an</strong> Failure Switch0 ....................................................... 2Discharge Air Sensing Tube0 ......................................... 3Clogged Filter Switch <strong>an</strong>d F<strong>an</strong> Fail Switch0 .................... 4Clogged Filter Switch <strong>an</strong>d DischargeAir Sensing Tube0 ...................................................... 5F<strong>an</strong> Fail Switch <strong>an</strong>d Discharge Air Sensing Tube0 .......... 6Clogged Filter <strong>an</strong>d F<strong>an</strong> Fail Switches<strong>an</strong>d Discharge Air Sensing Tube0 ............................... 7Novar Return Air Sensorq .............................................. 81 Enthalpy control not available factory installed with electro-mech<strong>an</strong>ical controls.2 Economizer with Barometric Relief is for downfllow configured units only. Order Economizer withoutBarometric Relief for horizontal configuration. Barometric relief for horizontal configured units mustbe ordered as field installed accessory BAYBARM010A.3 Requires use of Disconnect or Circuit Breaker.4 St<strong>an</strong>dard refrigeration metering device - short orifice.5 Frostat c<strong>an</strong>not be field installed in electro-mech<strong>an</strong>ical units.6 High Pressure control is st<strong>an</strong>dard on 3 phase units with scroll compressors.7 Not available with BAYFRST001A High Temperature Stat accessory.8 The return air smoke detector may not fit up or work properly on the Convertible units when used inconjunction with 3rd party accessories such as bolt on heat wheels, economizers <strong>an</strong>d powerexhaust. Do not order the return air smoke detectors when using this type of accessory.9 Return Air Smoke Detector c<strong>an</strong>not be ordered with Novar Controls.0 These options are st<strong>an</strong>dard when ordering Novar Controls.q This options for use when ordering Novar Control only.w Factory Supplied Field Installed.The m<strong>an</strong>ual outside air damper will ship factory supplied within theunit, but must be field installed.e Requires Selection of 2" Pleated Filters (Option B or C) for Digit 16.r Through the base electric required when ordering Disconnect/Circuit Breaker options.t Phase Monitor is st<strong>an</strong>dard on T/Y/WSC060A3,4,W models. All other models Phase Monitor will be<strong>an</strong> option.y Not available with electro-mech<strong>an</strong>ical unit controls.Heaters (Digit 10)kW Nominal No.Rating Digit BTUH Stages Used With208/240/3/604.5/6.0 (B) 13,400/20,500 1 THC033-063A39.0/12.0 (E) 30,800/59,400 2 THC033-063A313.2/17.6 (G) 44,600/59,400 2 THC033-063A317.2/23.0 (J) 58,900/78,500 2 THC063A3kW Nominal No.Rating Digit BTUH Stages Used With460/3/606.0 (B) 20,500 1 THC033-063A412.0 (E) 41,000 2 THC033-063A417.6 (G) 59,400 2 THC033-063A423.0 (J) 78,500 2 THC063A4575/3/606.0 (B) 20,500 1 THC033-063AW12.0 (E) 41,000 2 THC033-063AW17.6 (G) 59,400 2 THC033-063AW23.0 (J) 78,500 2 THC063AWFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-39 Effective 1/1/06


Precedent Packaged CoolingConvertible 3-5 Tons 13 SEER R-22Table PC-40-A — Accessory Electric Heaters – Unit with heater is single circuit / single point power entryModel Power kW Nominal No.Number Supply Rating BTUH Stages Used WithBAYHTRR306A 208/240/3/60 4.5/6.0 13,400/20,500 1 THC033-063A3BAYHTRR312A 208/240/3/60 9.0/12.0 30,800/41,000 2 THC033-063A3BAYHTRR318A 208/240/3/60 13.1/17.4 44,600/59,400 2 THC033-063A3BAYHTRR323A 208/240/3/60 17.3/23.0 58,900/78,500 2 THC063A3BAYHTRR406A 460/3/60 6.0 20,500 1 THC033-063AA4BAYHTRR412A 460/3/60 12.0 41,000 2 THC033-063A4BAYHTRR418A 460/3/60 17.4 59,400 2 THC033-063A4BAYHTRR423A 460/3/60 23.0 78,500 2 THC063A4BAYHTRRW06A 575/3/60 6.0 20,500 1 THC033-063AWBAYHTRRW12A 575/3/60 12.0 41,000 2 THC033-063AWBAYHTRRW18A 575/3/60 17.4 59,400 2 THC033-063AWBAYHTRRW23A 575/3/60 23.0 78,500 2 THC063AWEffective 1/1/06PC-40For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Precedent Packaged CoolingConvertible 3-5 Tons 13 SEER R-22Table PC-41-A — AccessoriesModel Number Description Used WithBAYABRD001C ..................... ReliaTel Options Module ..................................................... See Note8BAYASCT0010r .................. Anti-Short-Cycle Timer ........................................................... THC033-063A_EBAYBARM010A6 .................. Barometric Relief .................................................................... THC033-063ABAYCCHT010B ..................... Cr<strong>an</strong>kcase Heater ................................................................... THC033-063A3BAYCCHT011B ..................... Cr<strong>an</strong>kcase Heater ................................................................... THC033-063A4,AWBAYCO2K001B5t ............... CO 2 Sensor Kit, Wall Mounted ................................................ THC033-063A_RBAYCO2K003B5t ............... CO 2 Sensor Kit, Duct Mounted ............................................... THC033-063A_RBAYCURB042A4 .................. Roof Curb ............................................................................... THC033-063ABAYDFPS003A58 ............... Clogged Filter Switch .............................................................. THC033-063A_RBAYDFPS004A58 ............... F<strong>an</strong> Failure Switch .................................................................. THC033-063A_RBAYDMPR051A5 .................. 0-50% Motorized Outside Air Damper .................................... THC033-063A_RBAYDMPR052A0 .................. 0-50% Motorized Outside Air Damper .................................... THC033-063A_EBAYDMPR053By .................. 0-50% M<strong>an</strong>ual Outside Air Damper ........................................ THC033-063ABAYECON085A5 .................. 0-100% Dry Bulb Economizer without Barometric Relief ...... THC033-063A_RBAYECON086A0 .................. 0-100% Dry Bulb Economizer without Barometric Relief ...... THC033-063A_EBAYENTH005A15 ............... Reference Enthalpy Kit ........................................................... BAYECON085ABAYENTH006A15 ............... Comparative Enthalpy Kit ....................................................... BAYECON085ABAYENTH001A ..................... Enthalpy Control (Solid State) ................................................ BAYECON0086ABAYFRST001A50 ................ High Temperature Stat ........................................................... THC033-063A_RBAYGARD036B ..................... Condenser Coil Hail Guard ..................................................... THC033-043ABAYGARD037B ..................... Condenser Coil Hail Guard ..................................................... THC063ABAYHSMT073A ..................... .45 HP Oversized motor kit ..................................................... THC033A3BAYHSMT074A ..................... .45 HP Oversized motor kit ..................................................... THC033A4BAYHSMT075A ..................... .45 HP Oversized motor kit ..................................................... THC033AWBAYHSMT076A ..................... .75 HP Oversized motor kit ..................................................... THC043A3BAYHSMT077A ..................... .75 HP Oversized motor kit ..................................................... THC043A4BAYHSMT078A ..................... .75 HP Oversized motor kit ..................................................... THC043AWBAYHSMT079A ..................... 1.2 HP Oversized motor kit ..................................................... THC063A3BAYHSMT080A ..................... 1.2 HP Oversized motor kit ..................................................... THC063A4BAYHSMT081A ..................... 1.2 HP Oversized motor kit ..................................................... THC063AWBAYICSI003A5e .................. <strong>Tr<strong>an</strong>e</strong> Communications Interface (TCI) .................................. THC033-063A_RBAYLOAM020B258 ............ Evaporator Defrost Control (Frostat) ...................................... THC033-063A_RBAYLTCI002B5 .................... LonTalk ® Communications Interface (LCI) ............................. THC033-063A_RBAYQACB009A49 ............... Quick Adapt Roof Curb ........................................................... THC033-063ABAYQACB010A49 ............... Quick Adapt Roof Curb ........................................................... THC033-063ABAYSTAT0235 ..................... Remote Potentiometer ............................................................ BAYECON085ABAYSERV001A5 .................. Selective Resist<strong>an</strong>ce Service Tester ...................................... THC033-063A_RBAYSENS016A5 .................. Temperature Sensor ............................................................... THC033-063A_RBAYTUBE005A358 ............ Discharge Air Sensing Kit ....................................................... THC033-063A_RBAYVNOR001B58t ............ Ventilation Override Kit w/ReliaTel options module ............ THC033-063A_R1 Kits contain all necessary parts to achieve desiredlevel of enthalpy control.2 For ReliaTel microprocessor controlled unitsonly. Must be factory installed for electromech<strong>an</strong>icalcontrolled units3 Used for true discharge air sensing in bothheating <strong>an</strong>d cooling.Required for supply airtempering.4 Lynn Haven M<strong>an</strong>ufacturing has a No-Returnpolicy for this roof curb.5 For use with ReliaTel controlled units only6 Barometric Relief accessory installs in ductworkfor horizontal configuration. For downflowconfiguration, installs in the unit's horizontal returnduct. See Installer's Guide for completeinstructions.7 C<strong>an</strong>not be used in conjunction with factoryinstalled smoke detector.8 BAYABRD001C is required when ordering fieldinstalled accessories Clogged Filter Switch(BAYDFPS003A), F<strong>an</strong> Fail Switch(BAYDFPS004A), Discharge Air Sensing Kit(BAYTUBE004A) or Evaporator Defrost Control(Frostat) (BAYLOAM020B) Ventilation Override Kit(BAYVNOR001B) unless the following options arefactory installed: Frostat, Smoke Detector,Clogged Filter Switch, F<strong>an</strong> Failure Switch,Discharge Air Sensing Kit. These factory installedoptions include the ReliaTel Options Module.9 BAYQACB009A adapts Voyager BAYCURB021Bto accept Precedent 3-5 ton unit. BAYQACB010Aadapts Voyager BAYCURB022B to acceptPrecedent unit.0 For use with electromech<strong>an</strong>ical controlled unitsonly.q C<strong>an</strong>not be used in conjunction with BarometricRelief. Order Economizer without BarometricRelief.w BAYQACB012A adapts Voyager BAYCURB025Ato accept Precedent 6-10 ton unit.BAYQACB013A adapts Voyager BAYCURB026Ato accept Precedent 6-10 ton unit.BAYQACB011A adapts Voyager BAYCURB022 toaccept Precedent 6-10 ton unit.e Interface allows a unit with ReliaTel Controls tocommunicate with Tracer 100, Tracker, VariTrac II,<strong>an</strong>d is the preferred method of communication toTracer Summit.r Activated on Power On.t Field installed accessory requires economizer.y The m<strong>an</strong>ual outside air damper will ship factorysupplied within the unit, but must be field installed.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-41 Effective 1/1/06


Precedent Packaged CoolingConvertible 3-5 Tons 13 SEER R-22Table PC-42-A — Zone Sensors for ReliaTel Controlled UnitsModelNumber Description Used WithBAYMTPL003B Retrofit Wall Cover Plate Kit 7.25" x 6.0" BAYSENS019CBAYMTPL004B Retrofit Wall Cover Plate Kit 4.75" x 4.75" BAYSENS006,008010B,013,014C,017BBAYSENS006B Single Setpoint M<strong>an</strong>ual Ch<strong>an</strong>geover THC033-063A_RBAYSENS008B Dual Setpoint M<strong>an</strong>ual or Auto Ch<strong>an</strong>geover THC033-063A_RBAYSENS010B Dual Setpoint M<strong>an</strong>. or Auto Ch<strong>an</strong>geover with SystemFunction LightsTHC033-063A_RBAYSENS019C3 Programmable Night Setback w/System Function Lights THC033-063A_RBAYSENS013C1 Room Sensor w/ Override <strong>an</strong>d C<strong>an</strong>cel Buttons THC033-063A_RBAYSENS014C1 Room Sensor w/ Temp. Adjustment with Override <strong>an</strong>dC<strong>an</strong>cel ButtonsTHC033-063A_RBAYSENS017B Remote Room Sensor BAYSENS006B,008B,010B, & 019CBAYSENS032A8 Dual Thermistor Remote Zone Sensor THC033-063A_RBAYSENS035A8 Digital Display Zone Sensor THC033-063A_RBAYSENS036A7 Wall-Mounted Humidity Zone Sensor THC033-063A,3,4,WRBAYSENS037A7 Duct-Mounted Humidity Zone Sensor THC033-063A,3,4,WRTable PC-42-B — ThermostatsModelNumber Description Used WithBAY24X042 DPDT F<strong>an</strong> <strong>an</strong>d Electric Heat Relay BAYSTAT008,010BAY28X1904 Locking Thermostat Cover for up to 4 units Room ThermostatsBAYSTAT040B2 Programmable Thermostat THC033-063ABAYBASE008A Subbase 1-Stage Heating/Cooling BAYSTAT040BBAYBASE006A Subbase 2-Stage Heating/Cooling BAYSTAT040BBAYSENS033A Remote Wall Sensor BAYSTAT040BBAYSENS034A Remote Duct Sensor BAYSTAT040BBAYSTAT0083 M<strong>an</strong>ual 1-Stage Heating/Cooling THC033-063ABAYSTAT0103 Auto 2-Stage Heating/Cooling THC033-063ATCONT200AN11AA Electronic 1 Htg/1 Clg (Non Prog) THC033-063A1 Used with Integrated Comfort TM Systems, <strong>an</strong>y unit type. These sensors do not work with TCM. Consult BASD Marketing for them.2 Requires use of BAYBASE006A or BAYBASE008A.3 Requires DPDT F<strong>an</strong> <strong>an</strong>d Electric Heat Relay BAY24x042 when using electric heat.4 Do not use with programmable thermostats.5 Specially designed for electric heat applications (inst<strong>an</strong>t on f<strong>an</strong>).6 Use only with electromech<strong>an</strong>ical unit controls.7 For use with Dehumidification (Hot Gas Reheat) Coil Option.8 For use with ReliaTel Controls only.*Either st<strong>an</strong>dard or high efficiency modelsFor additional Controls Information:See ReliaTel <strong>an</strong>d Micro Control features on PC-35 <strong>an</strong>d PC-36.Effective 1/1/06PC-42For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Voyager PackagedCooling with ReliaTel Controls12½ through 25 Tons12½-25 Ton TCD — Downflow• Meets ASHRAE 90.1-1999• ReliaTel control features are listed onpage PC-35• Built-in <strong>an</strong>ti-short cycle, time-delay relay<strong>an</strong>d minimum on time controls• 2" st<strong>an</strong>dard for 12½ – 25 ton units• Liquid line drier• Built-in fork lift holes• Operating charge of R-22• “Quick Access” on 12½ – 25• Scroll compressors on all units• IAQ sloped condensate drain p<strong>an</strong>s• Dedicated horizontal <strong>an</strong>d downflow units• Single point power for electric heat• Complete line of optional electric heaters• Internally enh<strong>an</strong>ced coil tubing• Low ambient to 0°F st<strong>an</strong>dard• Colored <strong>an</strong>d numbered wiring• Quick-adjust idler arm pulley. Adjust belttension, ch<strong>an</strong>ge belts, adjust airflow quickly(12½ – 25 tons)• 5-year limited compressor warr<strong>an</strong>ty(12½ – 17½ tons)• 1-year limited compressor warr<strong>an</strong>ty(20 <strong>an</strong>d 25 tons)• 1-year limited parts warr<strong>an</strong>tyTable PC-43-A — TCD Downflow — Micro Control UnitUnit Power Supply Perform<strong>an</strong>ce Cooling Dimensions (in.) Shipping Max Fuse Size or5 DownflowTons Model No. Volts/Phase/Hz EER (3Ø) Capacity (Btuh) H x W x L Weight (Ibs.) MCA* Max Circuit Breaker* Roofcurb12 1 /2 TCD150D300B 208-230/3/60 9.8 150,000 50 x 72 x 108 1687 63 80 BAYCURB026B12 1 /2 TCD151C300B 208-230/3/60 11.3 154,000 50 1 /8 x 71 5 /16 x 107 5 /16 1776 64 80 BAYCURB026B15 TCD180B300H 208-230/3/60 9.9 182,000 50 x 72 x 108 1866 78 90 BAYCURB026B15 TCD181C300C4 208-230/3/60 11.5 189,000 54 x 85 5 /16 x 122 5 /16 2297 74 90 BAYCURB027B17 1 /2 TCD210C300E 208-230/3/60 9.8 210,000 50 x 72 x 108 2202 88 110 BAYCURB026B17 1 /2 TCD211C300C 208-230/3/60 11.0 220,000 54 x 85 5 /16 x 122 5 /16 2372 91 110 BAYCURB027B20 TCD240B300J 208-230/3/60 9.7 242,000 54 x 86 x 123 2772 100 125 BAYCURB027B20 TCD241C300C 208-230/3/60 10.6 268,000 54 x 85 5 /16 x 122 5 /16 2470 99 125 BAYCURB027B25 TCD300B300H 208-230/3/60 9.7 290,000 54 x 85 5 /16 x 122 5 /16 2365 118 150 BAYCURB027B25 TCD301C300C 208-230/3/60 10.4 300,000 54 x 85 5 /16 x 122 5 /16 2475 120 150 BAYCURB027B12 1 /2 TCD150D400B 460/3/60 9.8 150,000 50 x 72 x 108 1687 33 40 BAYCURB026B12 1 /2 TCD151C400B 460/3/60 11.3 154,000 50 1 /8 x 71 5 /16 x 107 5 /16 1776 31 40 BAYCURB026B15 TCD180B400H 460/3/60 9.9 182,000 50 x 72 x 108 1866 39 50 BAYCURB026B15 TCD181C400C4 460/3/60 11.5 189,000 54 x 85 5 /16 x 122 5 /16 2292 36 50 BAYCURB027B17 1 /2 TCD210C400E 460/3/60 9.8 210,000 50 x 72 x 108 2202 44 50 BAYCURB026B17 1 /2 TCD211C400C 460/3/60 11.0 220,000 54 x 85 5 /16 x 122 5 /16 2380 44 60 BAYCURB027B20 TCD240B400J 460/3/60 9.7 242,000 54 x 86 x 123 2372 50 60 BAYCURB027B20 TCD241C400C 460/3/60 10.6 268,000 54 x 85 5 /16 x 122 5 /16 2470 50 60 BAYCURB027B25 TCD300B400H 460/3/60 9.7 290,000 54 x 85 5 /16 x 122 5 /16 2365 58 70 BAYCURB027B25 TCD301C400C 460/3/60 10.4 300,000 54 x 85 5 /16 x 122 5 /16 2475 58 70 BAYCURB027B12 1 /2 TCD150DW00B 575/3/60 9.8 150,000 50 x 72 x 108 1687 26 30 BAYCURB026B12 1 /2 TCD151CW00B 575/3/60 11.3 154,000 50 1 /8 x 71 5 /16 x 107 5 /16 1776 25 30 BAYCURB026B15 TCD180BW00H 575/3/60 9.9 182,000 50 x 72 x 108 1866 31 40 BAYCURB026B15 TCD181CW00C4 575/3/60 11.5 189,000 54 x 85 5 /16 x 122 5 /16 2297 29 40 BAYCURB027B17 1 /2 TCD210CW00E 575/3/60 9.8 210,000 50 x 72 x 108 2702 35 45 BAYCURB026B17 1 /2 TCD211CW00C 575/3/60 11.0 220,000 54 x 85 5 /16 x 122 5 /16 2380 35 45 BAYCURB027B20 TCD240BW00J 575/3/60 9.7 242,000 54 x 86 x 123 2372 40 45 BAYCURB027B20 TCD241CW00C 575/3/60 10.6 268,000 54 x 85 5 /16 x 122 5 /16 2470 40 50 BAYCURB027B25 TCD300BW00H 575/3/60 9.7 290,000 54 x 85 5 /16 x 122 5 /16 2365 46 50 BAYCURB027B25 TCD301CW00C 575/3/60 10.4 300,000 54 x 85 5 /16 x 122 5 /16 2475 47 60 BAYCURB027BSupply Return Curb Size Roof OpeningModel No.Downflow W x L12Downflow W x L12H x W x L13W x L12TC❋150, 151, 180, 210 28 9 /16 x 55 1 /2 20 7 /8 x 63 14 1 /16 x 66 15 /16 x 102 1 /4 62 1 /2 x 73 1 /2TC❋181, 211-301 28 9 /16 x 69 1 /2 22 1 /4 x 77 14 1 /16 x 80 15 /16 x 117 1 /8 76 1 /2 x 81MCA = Minimum Circuit Ampacity.Maximum Fuse = Maximum Fuse Size or Maximum HACR Type Circuit Breaker Size.1 Dimensions are in inches. See Outline Dimensions.2 Interior Dimension.3 Measurement Includes Curb Fl<strong>an</strong>ge.4 Uses 17½ – 25 ton dimensions.5 HACR type circuit breaker per NEC.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-43 Effective 1/1/06


Voyager PackagedCooling with ReliaTel Controls12½ through 25 Tons12½-25 Ton TCH — Horizontal• Meets ASHRAE 90.1-1999• Reliatel control features are listed onpage PC-35• Built-in <strong>an</strong>ti-short cycle, time-delay relay<strong>an</strong>d minimum on time controls• 2" filters for 12½ – 25 ton units• Liquid line drier• Built-in fork lift holes• Operating charge of R-22• “Quick Access” on 12½ – 25• Scroll compressors on all units• IAQ sloped drain p<strong>an</strong>s• Dedicated horizontal <strong>an</strong>d downflow units• Single point power for electric heat• Complete line of optional electric heaters• Internally enh<strong>an</strong>ced coil tubing• Low ambient to 0°F st<strong>an</strong>dardTable PC-44-A — TCH Horizontal — Micro Control UnitUnit Power Supply Perform<strong>an</strong>ce Cooling Dimensions (in.) Shipping Max Fuse Size or4Tons Model No. Volts/Phase/Hz EER (3Ø) Capacity (Btuh) H x W x L Weight (Ibs.) MCA* Max Circuit Breaker*12 1 /2 TCH150D300B 208-230/3/60 9.8 150,000 50 x 72 x 108 1687 63 8012 1 /2 TCH151C300C 208-230/3/60 11.3 154,000 50 x 72 x 108 1776 64 8015 TCH180B300H 208-230/3/60 9.9 182,000 50 x 72 x 108 1866 78 9015 TCH181C300C3 208-230/3/60 11.5 189,000 54 x 86 x 123 2297 74 10017 1 /2 TCH210C300E 208-230/3/60 9.8 210,000 50 x 72 x 108 2202 88 10017 1 /2 TCH211C300C 208-230/3/60 11.0 220,000 54 x 86 x 123 2380 91 11020 TCH240B300J 208-230/3/60 9.7 242,000 54 x 86 x 123 2372 100 12520 TCH241C300C 208-230/3/60 10.6 268,000 54 x 86 x 123 2470 99 12525 TCH300B300H 208-230/3/60 9.7 290,000 54 x 86 x 123 2365 118 15025 TCH301C300C 208-230/3/60 10.4 300,000 54 x 86 x 123 2475 120 15012 1 /2 TCH150D400B 460/3/60 9.8 150,000 50 x 72 x 108 1687 33 4012 1 /2 TCH151C400C 460/3/60 11.3 154,000 50 x 72 x 108 1776 31 4015 TCH180B400H 460/3/60 9.9 182,000 50 x 72 x 108 1866 39 5015 TCH181C400C3 460/3/60 11.5 189,000 54 x 86 x 123 2292 36 5017 1 /2 TCH210C400E 460/3/60 9.8 210,000 50 x 72 x 108 2202 44 5017 1 /2 TCH211C400C 460/3/60 11.0 220,000 54 x 86 x 123 2380 44 6020 TCH240B400J 460/3/60 9.7 242,000 54 x 86 x 123 2372 50 6020 TCH241C400C 460/3/60 10.6 268,000 54 x 86 x 123 2470 50 6025 TCH300B400H 460/3/60 9.7 290,000 54 x 86 x 123 2365 58 7025 TCH301C400C 460/3/60 10.4 300,000 54 x 86 x 123 2475 58 7012 1 /2 TCH150DW00B 575/3/60 9.8 150,000 50 x 72 x 108 1687 26 3012 1 /2 TCH151CW00C 575/3/60 11.3 154,000 50 x 72 x 108 1776 25 3015 TCH180BW00H 575/3/60 9.9 182,000 50 x 72 x 108 1866 31 4015 TCH181CW00C3 575/3/60 11.5 189,000 54 x 86 x 123 2297 29 4017 1 /2 TCH210CW00E 575/3/60 9.8 210,000 50 x 72 x 108 2202 35 4517 1 /2 TCH211CW00C 575/3/60 11.0 220,000 54 x 86 x 123 2380 35 4520 TCH240BW00J 575/3/60 9.7 242,000 54 x 86 x 123 2372 40 4520 TCH241CW00C 575/3/60 10.6 268,000 54 x 86 x 123 2470 40 5025 TCH300BW00H 575/3/60 9.7 290,000 54 x 86 x 123 2365 46 5025 TCH301CW00C 575/3/60 10.4 300,000 54 x 86 x 123 2475 47 60SupplyReturnModel No.Horizontal H x W12Horizontal H x W12TC❋ 150,151, 180, 210 42 1 /2 x 26 1 /2 42 1 /2 x 24 9 /16TC❋181, 211-301 46 7 /16 x 26 1 /2 46 7 /16 x 27 9 /16MCA = Minimum Circuit Ampacity.Maximum Fuse = Maximum Fuse Size or Maximum HACR Type Circuit Breaker Size.1 Dimensions are in inches. See Outline Dimensions.2 Interior Dimension.3 Uses 17½ – 25 ton dimensions.4 HACR type circuit breaker per NEC.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.• Colored <strong>an</strong>d numbered wiring• Quick-adjust idler arm pulley. Adjust belttension, ch<strong>an</strong>ge belts, adjust airflow quickly(12½ – 25 tons)• 5-year limited compressor warr<strong>an</strong>ty(12½ – 17½ tons)• 1-year limited compressor warr<strong>an</strong>ty(20 <strong>an</strong>d 25 tons)• 1-year limited parts warr<strong>an</strong>tyEffective 1/1/06PC-44For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Voyager PackagedCooling with ReliaTel Controls12½ through 25 TonsTable PC-45-A — Factory Installed Accessories12For Complete list of all Factory Installed Options, please refer to the FIOPSsection of this book.Digit Description Order Number Used With1-9 Main Assembly (see previous page)10 Factory Installed OptionsNo Options 0 TC*150-301Downflow Economizer3 A TCD150-301Oversized Motor B TC*150-241Downflow Economizer <strong>an</strong>d Oversized Motor3 C TCD150-241<strong>Tr<strong>an</strong>e</strong> Communications Interface (TCI)4 F TC*150-301Downflow Economizer TCI34 G TCD150-301TXV/Face - Split Evaporator H TCD151, 181, 211, 241, 301Oversized Motor <strong>an</strong>d TXV/Face -Split Evaporator J TCD151, 181, 211, 241Downflow Economizer, Oversized Motor <strong>an</strong>d TXV/Face K TCD151, 181, 211, 241Split Evaporator34Downflow Economizer with TXV/Face - Split Evaportor3 L TCD151, 181, 211, 241, 301Reheat Coil5 M TCD151, 181, 241Downflow Economizer with Reheat Coil35 N TCD151, 181, 241Oversized Motor <strong>an</strong>d Reheat Coil5 P TCD151, 181, 241Downflow Economizer, Oversized Motor <strong>an</strong>d R TCD151, 181, 241Reheat Coil 3511-12 Minor Design <strong>an</strong>d Service Sequence **1 Price includes accessory <strong>an</strong>d factory installation.2 Four (4) week shipping approximately.3 Some field set up required.4 TCI is for use with non-VariTrac systems <strong>an</strong>d VariTrac systems.5 All 10th digit model numbers including reheat coil (M,N,P,R) require additional factory installed options; ReliaTel Options Module (FIYABRD002B), Frostat(FIYLOAM023A), <strong>an</strong>d 2" Pleated Filters (FIYPLTD001A, 002A, or 003A refer to FIOPS section for appropriate model number usage). For these or <strong>an</strong>y FactoryInstalled Options not included in 10th digit model number, digits 1-3 must be TFD.Table PC-45-B — Zone SensorsModel Number Description Used WithBAYSENS006B ......... Single Setpoint M<strong>an</strong>ual Ch<strong>an</strong>geover ......................................................... TC*150-301BAYSENS008B ......... Dual Setpoint M<strong>an</strong>ual or Automatic Ch<strong>an</strong>geover ...................................... TC*150-301BAYSENS010B ......... Dual Setpoint M<strong>an</strong>ual or Automatic Ch<strong>an</strong>geover ...................................... TC*150-301with System Function LightsBAYSENS019C ........ Programmable Night Setback with System Function Lights ..................... TC*150-301BAYSENS013C1 .... Room Sensor with Override Button ........................................................... TC*150-301BAYSENS014C1 .... Room Sensor with Temperature Adjustment <strong>an</strong>d Override ....................... TC*150-301BAYSENS017B ......... Remote Room Sensor ............................................................................... BAYSENS006B, 008B,010B <strong>an</strong>d 019CBAYSENS032Ay ..... Dual Thermistor Remote Zone Sensor ...................................................... TC*150-301BAYSENS035Ay ..... Digital Display Zone Sensor ....................................................................... TC*150-301BAYSENS036A ......... Wall-Mounted Humidity Sensor ................................................................. TFD151,181,241 (with Reheat)BAYSENS037A ......... Duct-Mounted Humidity Sensor ................................................................ TFD151,181,241 (with Reheat)BAYCLCK001Au ...... Electronic Time Clock for up to 4 units ...................................................... BAYSENS006B,008B, 010BBAYMTPL003B ......... Retrofit Wall Cover Plate Kit (7 1 /4" x 6") ..................................................... BAYSENS019CBAYMTPL004A ........ Retrofit Wall Cover Plate Kit (4 3 /4" x 4 3 /4") ................................................. BAYSENS006B, 008B, 010B, 017B<strong>an</strong>d 013, 014CFor additional Controls Information:See ReliaTel <strong>an</strong>d Micro Control features on PC-35 <strong>an</strong>d PC-36.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-45 Effective 1/1/06


Voyager Packaged Coolingwith ReliaTel Controls12½ through 25 Tons AccessoriesTable PC-46-A — Field Installed AccessoriesFor complete list of of All Factory Installed Options refer to FIOPS section of this book.Model Number Description Used WithBAYABRD002e .......... ReliaTel Options Module ........................................................ TCD/TCH150-301BAYCO2K002Brt ..... CO 2 Sensor Wall Mounted ......................................................... TC*150-301 w/EconomizerBAYCO2K004Brt ..... CO 2 Sensor Duct Mounted ........................................................ TC*150-301 w/EconomizerBAYCURB026B67 .... Downflow Roof Curb (C<strong>an</strong> not be adapted for horizontal use) ..... TCD150D,151C, 180B, 210CBAYCURB027B67 .... Downflow Roof Curb (C<strong>an</strong> not be adapted for horizontal use) ..... TCD181C, 211C, 240B, 241C, 300B, 301CBAYDFPS005Awe ..... Clogged Filter Switch ................................................................ TCD/TCH (12½-25 Tons)BAYDFPS006Awe ..... F<strong>an</strong> Failure Switch .................................................................... All Economizers <strong>an</strong>d 0-50% Motorized Air DampersBAYDMPR029C .......... 0-25% M<strong>an</strong>ual Outside Air Damper ........................................... TCD/TCH (12½-25 Tons)BAYDMPR057A .......... 0-50% Motorized Outside Air Damper ........................................ TCD/TCH150D, 151C, 180B, 210CBAYDMPR058A .......... 0-50% Motorized Outside Air Damper ........................................ TCD/TCH181C, 211C, 240B, 241C, 300B, 301CBAYECON089Ae ....... Downflow Economizer with Barometric Relief ............................. TCD150D, 151C, 180B, 210CBAYECON090Ae ....... Downflow Economizer with Barometric Relief ............................. TCD181C211C, 240B, 241C, 300B, 301CBAYECON091A .......... Horizontal Economizer .............................................................. TCH151C, 180B, 210CBAYECON092A .......... Horizontal Economizer .............................................................. TCH181C211C, 240B, 241C, 300B, 301CBAYENTH007A12 ..... Reference Enthalpy Kit .............................................................. All BAYECNO089-92ABAYENTH008A123 .. Comparative Enthalpy Kit .......................................................... All BAYECNO089-92ABAYFRST003A0 ........ High Temperature Stat .............................................................. TCD/TCH150DBAYGARD043Be ....... Tool-less Hail Guard .................................................................. TC*150BAYGARD044Be ....... Tool-less Hail Guard .................................................................. T*C151C, 180B, 210CBAYGARD045Ae ....... Tool-less Hail Guard .................................................................. T*C181C, 211C, 241C, 301C, 240BBAYGARD047Ae ....... Tool-less Hail Guard .................................................................. TC*300BBAYHSDR002B4 ....... High Static Drive ....................................................................... TCD/TCH151CBAYHSDR005B4 ....... High Static Drive ....................................................................... TCD/TCH180B, 211C, 241C,TCD/TCH150DBAYHSDR010A4 ....... High Static Drive ....................................................................... TCD/TCH300B, 301CBAYHSDR011A4 ....... High Static Drive ....................................................................... TCD/TCH181CBAYHSMT039B4e .... 5HP Oversized Motor Kit ........................................................... TCD/TCH151C, 180B,150DBAYHSMT040B4e .... 5HP Oversized Motor Kit (575V) ................................................ T*151CW, 180BWBAYHSMT042A4e .... 7-1/2HP Oversized Motor Kit (575V) .......................................... TC*211C, 240B, 241CWBAYHSMT055B4e .... 5HP Oversized Motor Kit ........................................................... TCD/TCH181CBAYHSMT059A5e .... 7-1/2HP Oversized Motor Kit (230V) .......................................... TCD/TCH210CBAYHSMT060A5e .... 7-1/2HP Oversized Motor Kit (460V) .......................................... TCD/TCH210CBAYHSMT061A4e .... 7-1/2HP Oversized Motor Kit (575V) .......................................... TC*210CWBAYHSMT072A4e .... 7-1/2HP Oversized Motor Kit (575V) .......................................... TC*181CWBAYHSMT098A4e .... 7-1/2HP Oversized Motor Kit ..................................................... TC*211,240,241C3BAYHSMT099A4e .... 7-1/2HP Oversized Motor Kit ..................................................... TC*211,240,241C4BAYICSI004Bty ........ Comm 3/4 <strong>Tr<strong>an</strong>e</strong> Communications Interface (TCI) ...................... TC*150-301BAYLOAM023Ae ........ Evaporator Defrost Control Frostat ............................................. TC*150-301BAYLSDR004A5 ....... Low Static Drive ........................................................................ TCD/TCH210CBAYLSDR002A5 ....... Low Static Drive ........................................................................ TCD/TCH300B, 301CBAYLTCI003By .......... LonTalk ® Communications Interface (LCI) .................................. TC*150-301BAYPWRX029A .......... Power Exhaust for 230 volt units ................................................ BAYECON089-092ABAYPWRX030A .......... Power Exhaust for 460 volt units ................................................ BAYECON089-092ABAYPWRX031A .......... Power Exhaust for 575 volt units ................................................ TCD150DWBAYSENS016A ........... Temperature Sensor ................................................................. TCD/TCH (12½-25 Tons)BAYSERV001A ........... Selective Resist<strong>an</strong>ce Service Tester .......................................... TCD/TCH (12½-25 Tons)BAYSTAT0238 ............ Remote Potentiometer .............................................................. All Economizers <strong>an</strong>d 0-50% Motorized Air DampersBAYTUBE008A9we .. Discharge Air Sensing Kit .......................................................... TCD150D-301BAYTUBE009A9we .. Discharge Air Sensing Kit .......................................................... TCH150D-301BAYVNOR002Bw ...... Ventilation Override Kit ........................................................... TC*150-301 w/ReliaTel Options Module1 Kit contains all necessary parts to achieve desired level of Enthalpy Control.2 Reference Enthalpy senses outside temperature/humidity <strong>an</strong>d inside supply air only.3 Comparative Enthalpy senses outside temperature/humidity <strong>an</strong>d inside supply <strong>an</strong>d return air.4 High static drive <strong>an</strong>d oversized motors are mutually exclusive, Do Not Combine.5 Low static drive <strong>an</strong>d oversized motors are mutually exclusive, Do Not Combine.6 Clarksville m<strong>an</strong>ufacturing has a no return policy for this roof curb.7 For downflow use only. C<strong>an</strong> not be adapted for horizontal units.8 C<strong>an</strong>not be used with Integrated Comfort Systems.9 Used for true discharge air sensing in both heating <strong>an</strong>d cooling models.0 Must be used with either field or factory installed TCI (<strong>Tr<strong>an</strong>e</strong> Communications Interface).q C<strong>an</strong>not be used with economizer <strong>an</strong>d motorized outside air damper. For operational characteristics see Accessory IOM.w BAYABRD002B is required when ordering field installed BAYDFPS005A or 006A, BAYTUBE008A or 009A <strong>an</strong>d BAYLOAM023A or BAYVNOR002B.e Field or factory installed option.r Field installed accessory. Requires <strong>an</strong> economizer.t Interface allows a unit with ReliaTel Controls to communicate with Tracer 100, Tracker, VariTrac II, <strong>an</strong>d is the preferred method of communication to Tracer Summit.y With ReliaTel controlled units only.Effective 1/1/06PC-46For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Voyager PackagedCooling with ReliaTel Controls12½ through 25 TonsTable PC-47-A — Downflow /Horizontal Supplementary Heaters:Model Power kW Nominal No.Number Supply Rating BTUH Stages Used WithAYDHTRK318A 208/240/3/60 13.5/18.0 46,100/61,400 1 TCD180B,181C,150D3,151C3AYDHTRK336A 208/240/3/60 27.0/36.0 92,200/122,900 2 TCD180B,181C,150D3,151C3AYDHTRK354A 208/240/3/60 40.5/54.0 138,200/184,300 2 TCD180B,181C,150D3,151C3AYDHTRL418A 460/3/60 18.0 61,400 1 TCD150D, 180B4,181C4,151C4AYDHTRK427A 460/3/60 27.0 92,150 2 TCD181C4AYDHTRK436A 460/3/60 36.0 122,900 2 TCD150D, 180B4,181C4,151C4AYDHTRK454A 460/3/60 54.0 184,300 2 TCD150D, 180B4,181C4,151C4AYDHTRL336A 208/240/3/60 27.0/36.0 92,200/122,900 2 TCD210-301C3,B3AYDHTRL354A 208/240/3/60 40.5/54.0 138,200/184,300 2 TCD210-301C3,B3AYDHTRK372A 208/240/3/60 54.0/72.0 184,300/245,700 2 TCD211-301C3,B3AYDHTRL427A 460/3/60 27.0 92,150 2 TCD211-301C4AYDHTRL436A 460/3/60 36.0 122,900 2 TCD210-301C4,B4AYDHTRL454A 460/3/60 54.0 184,300 2 TCD210-301C4,B4AYDHTRK472A 460/3/60 72.0 245,700 2 TCD211-301C4,B4AYHHTRK318A 208/240/3/60 13.5/18.0 46,100/61,400 1 TCH181C3AYHHTRK336A 208/240/3/60 27.0/36.0 92,200/122,900 2 TCH181C3AYHHTRK354A 208/240/3/60 40.5/54.0 138,200/184,300 2 TCH181C3AYHHTRM418A 460/3/60 18.0 61,400 1 TCH181C4AYHHTRK436A 460/3/60 36.0 122,900 2 TCH181C4AYHHTRM454A 460/3/60 54.0 184,300 2 TCH181C4AYHHTRN318A 208/240/3/60 13.5/18.0 46,000/61,400 1 TCH150D3,180B3,151C3AYHHTRP336A 208/240/3/60 27.0/36.0 92,200/122,900 2 TCH150D3,180B3,151C3AYHHTRP354A 208/240/3/60 40.5/54.0 138,200/184,300 2 TCH150D3,180B3,151C3AYHHTRN418A 460/3/60 18.0 61,400 1 TCH150D, 180B4,151C4AYHHTRP436A 460/3/60 36.0 122,900 2 TCH150D, 180B4,151C4AYHHTRP454A 460/3/60 54.0 184,300 2 TCH150D, 180B4,151C4AYHHTRQ336A 208/240/3/60 27.0/36.0 92,200/22,900 2 TCH210C3AYHHTRQ354A 208/240/3/60 40.5/54.0 138,200/184,300 2 TCH210C3AYHHTRQ436A 460/3/60 36.0 122,900 2 TCH210C4AYHHTRQ454A 460/3/60 54.0 184,300 2 TCH210C4AYHHTRN336A 208/240/3/60 27.0/36.0 92,200/122,900 2 TCH211-301C3,B3AYHHTRN354A 208/240/3/60 40.5/54.0 138,200/184,300 2 TCH211-301C3,B3AYHHTRN372A 208/240/3/60 54.0/72.0 184,300/245,700 2 TCH211-301C3,B3AYHHTRN436A 460/3/60 36.0 122,900 2 TCH211-301C4,B4AYHHTRN454A 460/3/60 54.0 184,300 2 TCH211-301C4,B4AYHHTRN472A 460/3/60 72.0 245,700 2 TCH211-301C4,B4Note: Unit with heater is single circuit/single point.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PC-47 Effective 1/1/06


Voyager Packaged Coolingwith ReliaTel Controls12½ through 25 TonsTable PC-48-A — Downflow /Horizontal Supplementary Heaters:Model Power kW Nominal No.Number Supply Rating BTUH Stages Used WithAYDHTRKW18A 575/3/60 18.0 61,400 1 TCD150DW,180BW,151CW,181CAYDHTRKW36A 575/3/60 36.0 122,900 2 TCD150DW,180BW,210CW,181C240-300BW,211-301CWAYDHTRLW54A 575/3/60 54.0 184,300 2 TCD210CW,240-300B,211-301CWAYDHTRKW72A 575/3/60 72.0 245,700 2 TCD211-301CWAYDHTRMW36A 575/3/60 36.0 122,900 2 TCD150DW,180BW,210CW181C,240-300BW,211-301CWAYDHTRMW72A 575/3/60 72.0 245,700 2 TCD240-300BWAYHHTRMW18A 575/3/60 18.0 61,400 1 TCD181CAYHHTRMW36A 575/3/60 36.0 122,900 2 TCH181CW,211-301CWAYHHTRMW54A 575/3/60 54.0 184,300 2 TCH240-300BW,181CAYHHTRNW18A 575/3/60 18.0 61,400 1 TCH150DW,180BW,151C,181CAYHHTRNW54A 575/3/60 54.0 184,300 2 TCH240-300BW,211-301CWAYHHTRNW72A 575/3/60 72.0 245,700 2 TCH240-300BW,211-301CWAYHHTRPW36A 575/3/60 36.0 122,900 2 TCH150DW,180BW,210CW,151CAYHHTRPW54A 575/3/60 54.0 184,300 2 TCH150DW,180BW,151CAYHHTRQW54A 575/3/60 54.0 184,300 2 TCH210CWAYHHTRKW72A 575/3/60 72.0 245,700 2 TCH211-301CWNote: Unit with heater is single circuit/single point.See ReliaTel <strong>an</strong>d Micro Control features on PC-35 <strong>an</strong>d PC-36.Effective 1/1/06PC-48For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Heat PumpConvertible 1½ through 5 Tons• Architectual Louvers <strong>an</strong>d Corner Guards fordurable protection <strong>an</strong>d extra safety.• Appli<strong>an</strong>ce Grade Finish durable powder paintbaked on both sides of every p<strong>an</strong>el.• Weater Beater top contoured <strong>an</strong>d reinforcedfor strength.• Exclusive Climatuff ® high efficiencycompressor• Aerospace Ducted Outdoor f<strong>an</strong> for quietoperation• Composite Vortica ® Blower uses lessenergy to provide more air with less sound.• Side electrical service access for high <strong>an</strong>dlow voltage• Sloped composite no-rust drain p<strong>an</strong>• Shipped for horizontal application, easilyconvertible to downflow• One electric heater family• Optional filter rack fits inside unit• Low voltage polarized plug for easy electricheater installation• Heavy gauge steel cabinet with weatherresist<strong>an</strong>t, baked enamel finish• Top discharge f<strong>an</strong>• Dem<strong>an</strong>d defrost control• Refriger<strong>an</strong>t line filter drier• Solenoid operated switchover valve• Copper tube, aluminum plate fin Indoor coil• Exp<strong>an</strong>sion valve no bleed on outdoor coil• High efficiency outdoor f<strong>an</strong> motor withpolarized plug• Exp<strong>an</strong>sion valve no bleed on indoor coil• Water shed base• UL Listed• Cr<strong>an</strong>kcase heater• Direct drive blower 2-speed motor• Compressor internal overload protection• Protected pressure taps for refriger<strong>an</strong>tchecks• St<strong>an</strong>dard operation to 55°F. as m<strong>an</strong>ufactured• Low ambient cooling to 0°F. withBAYLOAM105A• 10-year limited compressorwarr<strong>an</strong>ty, 5-year other parts single phase(<strong>Residential</strong> Use Only)• Optional extended warr<strong>an</strong>tiesTable PH-1-A — 2WCX - XL13c - Convertible Package Heat Pump - R-22CabinetModel Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H x W x L2WCX – 208/230/1/602WCX3024A1000A 23,200 13.45/11.80 7.9 453 11.5 20 72 36 x 51 x 432WCX3030A1000A 29,400 13.05/11.00 8.4 454 17.1 25 72 36 x 51 x 432WCX3036A1000A 37,200 13.20/11.00 8.0 468 24.2 40 75 36 x 51 x 432WCX3042A1000A 40,000 13.10/11.20 8.25 529 24.6 40 73 38 x 61 x 462WCX3048A1000A 47,000 13.30/11.30 7.95 553 28.6 45 73 38 x 61 x 462WCX3060A1000A 58,500 13.35/11.25 8.3 623 40.4 60 72 42 x 61 x 46Table PH-1-B — 4WCX - XL13c - Convertible Package Heat Pump - R-410ACabinetModel Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H x W x L4WCX – 208/230/1/604WCX3018A1000A 18,600 13.15/11.10 7.7 444 10.6 15 69 36 x 51 x 434WCX3036A1000A 36,200 13.20/11.00 7.75 468 25.5 40 71 36 x 51 x 434WCX3048A1000A 46,000 13.15/10.75 8.25 553 31.1 50 73 38 x 61 x 464WCX3060A1000A 59,500 13.05/10.85 7.85 618 43.3 60 72 40 x 61 x 464WCX – 208/230/3/604WCX3036A3000A 36,200 13.20/11.00 7.75 468 18.2 30 71 36 x 51 x 434WCX3048A3000A 46,600 13.15/10.75 8.25 553 23.6 35 73 38 x 61 x 464WCX3060A3000A 59,500 13.05/10.85 7.85 618 31.5 50 72 40 x 59 x 444WCX– 460/3/604WCX3036A4000A 36,200 13.20/11.00 7.75 468 8.7 15 71 36 x 51 x 434WCX3048A4000A 46,000 13.15/10.75 8.25 553 11.7 15 73 38 x 61 x 464WCX3060A4000A 59,500 13.05/10.85 7.85 618 19.3 25 72 40 x 61 x 46For information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PH-1 Effective 1/1/06


Package Heat PumpConvertible 1½ through 5 Tons2/4WCX3018A through 2/4WCX3036AFor information on Roof Curbs <strong>an</strong>dRoof Curb Adaptors, please refer tothe Accessories/Information Tab.Effective 1/1/06PH-2For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Heat PumpConvertible 1½ through 5 Tons2/4WCX3018A through 2/4WCX3036AFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PH-3 Effective 1/1/06


Package Heat PumpConvertible 1½ through 5 Tons2/4WCX3042A through 2/4WCX3060AFor information on Roof Curbs <strong>an</strong>dRoof Curb Adaptors, please refer tothe Accessories/Information Tab.Effective 1/1/06PH-4For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Heat PumpConvertible 1½ through 5 Tons2/4WCX3042A through 2/4WCX3060AFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PH-5 Effective 1/1/06


Package Heat PumpConvertible 1½ through 5 Tons• Climatuff ® high efficiencycompressor• Shipped for horizontal application, easilyconvertible to downflow• One electric heater family• Optional filter rack fits inside unit• Low voltage polarized plug for easy electricheater installation• Heavy gauge steel cabinet with weatherresist<strong>an</strong>t, baked enamel finish• Top discharge f<strong>an</strong>• Dem<strong>an</strong>d defrost control• Refriger<strong>an</strong>t line filter drier• Solenoid operated switchover valve• Copper tube, aluminum plate fin Indoor coil• Exp<strong>an</strong>sion valve no bleed on outdoor coilTable PH-6-A — 2WCC - XB13c - Convertible Package Heat Pump - R-22CabinetModel Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H x W x L2WCC– 208/230/1/602WCC3024A1000A 23,000 13.00/11.00 7.7 453 12.5 20 76 36 x 49 x 422WCC3030A1000A 28,000 13.00/11.00 7.7 454 17.1 25 76 36 x 49 x 422WCC3036A1000A 35,000 13.00/11.00 7.7 468 24.2 40 75 36 x 49 x 422WCC3042A1000A 40,000 13.00/11.00 7.7 529 24.6 40 78 38 x 59 x 442WCC3048A1000A 45,500 13.00/11.00 7.7 553 28.6 45 79 38 x 59 x 442WCC3060A1000A 58,000 13.00/11.00 7.7 623 40.4 60 79 42 x 59 x 44Table PH-6-B — 4WCC - XB13c - Convertible Package Heat Pump - R-410ACabinetModel Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H x W x L4WCC– 208/230/1/604WCC3018A1000A 18,000 13.00/11.00 7.7 444 10.6 15 74 36 x 49 x 424WCC3036A1000A 35,000 13.00/11.00 7.7 468 25.5 40 75 36 x 49 x 424WCC3048A1000A 45,500 13.00/10.75 7.7 553 31.1 50 80 38 x 59 x 444WCC3060A1000A 58,000 13.00/10.85 7.7 618 43.3 60 79 40 x 59 x 444WCC – 208/230/3/604WCC3036A3000A 35,000 13.00/11.00 7.7 468 18.2 30 75 36 x 49 x 424WCC3048A3000A 45,500 13.00/10.75 7.7 553 23.6 35 80 38 x 59 x 444WCC3060A3000A 58,000 13.00/10.85 7.7 618 31.5 50 79 40 x 59 x 444WCC– 460/3/604WCC3036A4000A 35,000 13.00/11.00 7.7 468 8.7 15 75 36 x 49 x 424WCC3048A4000A 45,500 13.00/10.75 7.7 553 11.7 15 80 38 x 59 x 444WCC3060A4000A 58,000 13.00/10.85 7.7 618 19.3 25 79 40 x 59 x 44• High efficiency outdoor f<strong>an</strong> motorwith polarized plug• Exp<strong>an</strong>sion valve no bleed on indoor coil• Water shed base• UL Listed• Cr<strong>an</strong>kcase heater• Direct drive blower 2-speed motor• Compressor internal overload protection• Protected pressure taps forrefriger<strong>an</strong>t checks• St<strong>an</strong>dard operation to 55°F. as m<strong>an</strong>ufactured• Low ambient cooling to 0°F. withBAYLOAM105A• 5-year limited compressorwarr<strong>an</strong>ty, 5-year other parts single phase(<strong>Residential</strong> Use Only)• Optional extended warr<strong>an</strong>tiesFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.Effective 1/1/06PH-6For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Heat PumpConvertible 1½ through 5 Tons2/4WCC3018A through 2/4WCC3036AFor information on Roof Curbs <strong>an</strong>dRoof Curb Adaptors, please refer tothe Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PH-7 Effective 1/1/06


Package Heat PumpConvertible 1½ through 5 Tons2/4WCC3018A through 2/4WCC3036AFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.Effective 1/1/06PH-8For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Heat PumpConvertible 1½ through 5 Tons2/4WCC3042A through 2/4WCC3060AFor information on Roof Curbs <strong>an</strong>dRoof Curb Adaptors, please refer tothe Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PH-9 Effective 1/1/06


Package Heat PumpConvertible 1½ through 5 Tons2/4WCC3042A through 2/4WCC3060AFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.Effective 1/1/06PH-10For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Heat PumpConvertible 1½ through 5 Tons2WCX 4WCX 2WCC 4WCCTable PH-11-A — Accessories 2-5 1½-5 2-5 1½-5BAYADAP050A ............... Adapter Curb (Cabinet A/B) .......................................................................... 1½-3 1½-3 1½-3 1½-3BAYADAP051A ............... Adapter Curb (Cabinet C) ............................................................................. 1½-3 1½-3 1½-3 1½-3BAYADAP052A ............... Adapter Curb (Cabinet A/B) .......................................................................... 3½-5 3½-5 3½-5 3½-5BAYADAP053A ............... Adapter Curb (Cabinet C) ............................................................................. 3½-5 3½-5 3½-5 3½-5BAYADAP054A ............... Adapter Curb (Cabinet D) ............................................................................. 3½-5 3½-5 3½-5 3½-5BAYCCHT101A .............. Cr<strong>an</strong>kcase Heater (230V) ............................................................................. 2-2½,5 1½ 2-2½,4 1½BAYCCHT102A .............. Cr<strong>an</strong>kcase Heater (230V) ............................................................................. 3-3½ 3, 4 3-3½ 3,4BAYCCHT104A .............. Cr<strong>an</strong>kcase Heater (460V) ............................................................................. — 5 — 5BAYCOVR112A .............. 12" Duct Shroud (Covers Horizontal Ducts)w ................................................ 3½-5 3½-5 3½-5 3½-5BAYCOVR118A .............. 18" Duct Shroud (Covers Horizontal Ducts)w ................................................ 3½-5 3½-5 3½-5 3½-5BAYCURB050A .............. Flat Roof Curb (Insulated)3 .......................................................................... 1½-3 1½-3 1½-3 1½-3BAYCURB051A .............. Flat Roof Curb (Insulated)3 .......................................................................... 3½-5 3½-5 3½-5 3½-5BAYDMPR101A .............. 2-Position Motorized Damper ........................................................................ 1½-3 1½-3 1½-3 1½-3BAYDMPR102A .............. 2-Position Motorized Damper ........................................................................ 3½-4 3½-4 3½-4 3½-4BAYECON101A .............. Economizer with Barometric Relief12458 .................................................. 1½-3 1½-3 1½-3 1½-3BAYECON102A .............. Economizer with Barometric Relief12458 .................................................. 3½-4 3½-4 3½-4 3½-4BAYECON200A .............. Economizer (Horizontal)1248 ..................................................................... ✔ ✔ ✔ ✔BAYECON201A .............. Economizer (Horizontal)1248 ..................................................................... 3½-5 3½-5 3½-5 3½-5BAYENTH100A .............. Enthalpy Control Kit4 .................................................................................... ✔ ✔ ✔ ✔BAYEXMK001A .............. Extreme Conditions Mounting Kit .................................................................. ✔ ✔ ✔ ✔BAYEXMK002A .............. Extreme Conditions Mounting Kit .................................................................. ✔ ✔ ✔ ✔BAYEXMK003A .............. Extreme Conditions Mounting Kit (Used on Slab Mounts) ............................. ✔ ✔ ✔ ✔BAYFLTR101A ................ 1-2" Filter Frame2 ......................................................................................... 1½-3 1½-3 1½-3 1½-3BAYFLTR201A ................ 1-2" Filter Frame2 ......................................................................................... 3½-4 3½-4 3½-4 3½-4BAYLIFT002B ................. Lifting Lug Kit ............................................................................................... ✔ ✔ ✔ ✔BAYLOAM011A .............. Evaporator Defrost Control Kit ....................................................................... ✔ ✔ ✔ ✔BAYLOAM105A .............. Low Ambient Control Kitq ............................................................................. ✔ ✔ ✔ ✔BAYOSAH001A .............. M<strong>an</strong>ual Fresh Air Damper25 ........................................................................ 1½-3 1½-3 1½-3 1½-3BAYOSAH002A .............. M<strong>an</strong>ual Fresh Air Damper25 ........................................................................ 3½-4 3½-4 3½-4 3½-4BAYQSTK300A .............. Quick Start Kit ............................................................................................... 1 Phase Only 1 Phase Only 1 Phase Only 1 Phase OnlyBAYSQRD001A .............. 16" Round Duct Adapter0 ........................................................................... 1½-3 1½-3 1½-3 1½-3BAYSQRD002A .............. 18" Round Duct Adapter0 ........................................................................... 1½-5 1½-5 1½-5 1½-5BAYUTIL101A ................ Roof Curb Extension Kit ................................................................................ 1½-3 1½-3 1½-3 1½-3BAYUTIL102A ................ Roof Curb Extension Kit ................................................................................ 3½-4 3½-4 3½-4 3½-41 Relay required with economizer on all 2/4WC*3 models.2 Must use filter frame when economizer/fresh air kit is used.3 Ships knocked down.4 Dry bulb control st<strong>an</strong>dard with economizer.5 Downflow Only.6 Full perimeter curb for 2/4WC*3018-036A models.7 Full perimeter curb for 2/4WC*3042-060A models.8 2-Stage thermostat provides additional energy savings if simult<strong>an</strong>eous economizer <strong>an</strong>d compressor operation is expected.9 Do not use with programmable thermostats.0 It is the responsibility of the installing dealer to properly size the ductwork for each specific application.q BAYRLAY005A, required on all heat pump applications.w BAYCOVR112,118A will not cover BAYSQRD002A applicationsFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PH-11 Effective 1/1/06


Package Heat PumpConvertible 1½ through 5 TonsTable PH-12-A — Supplementary Heaters – Separate power source /power entry requiredModelShippingNumber Description Used With WeightBAYHTRV105A 3.76/5.0 kW Heater (208/240V 1PH) 2/4WC*3018-060A1 9BAYHTRV110A 7.50/10.0 kW Heater (208/240V 1PH) 2/4WC*3024-060A1 10BAYHTRV115A 11.27/15.00 kW Heater (208/240V 1PH) 2/4WC*3030-060A1 14BAYHTRV120A 15.0/20.0 kW Heater (208/240V 1PH) 2/4WC*3048-060A1 14BAYHTRV305A 3.76/5.0 kW Heater (208/240V 3PH) 2/4WC*3018-060A3 9BAYHTRV310A 7.50/10.0 kW Heater (208/240V 3PH) 2/4WC*3024-060A3 10BAYHTRV315A 11.27/15.00 kW Heater (208/240V 3PH) 2/4WC*3030-060A3 14BAYHTRV320A 15.00/20.0 kW Heater (208/240V 3PH) 2/4WC*3048-060A3 14BAYHTRV405A 3.76/5.0 kW Heater (460V 3PH) 2/4WC*3018-060A4 9BAYHTRV410A 7.50/10.0 kW Heater (460V 3PH) 2/4WC*3024-060A4 10BAYHTRV415A 11.27/15.00 kW Heater (460V 3PH) 2/4WC*3030-060A4 14BAYHTRV420A 15.00/20.0 kW Heater (460V 3PH) 2/4WC*3048-060A4 14Table PH-12-B — Single Power Entry Kit/Heater Matrix:Single Power Heater Unit ShippingEntry Kit1 Model Model WeightBAYSPEK060A BAYHTRV105A 2WC*3024-048A1 34WC*3018-036A1BAYSPEK061A BAYHTRV305A 4WC*3036-060A3 7BAYHTRV310A4WC*3036-048A3BAYHTRV405A4WC*3036-060A4BAYHTRV410A4WC*3036-060A4BAYHTRV415A4WC*3036-060A4BAYHTRV420A4WC*3048-060A4BAYSPEK062A BAYHTRV105A 4WC*3048-060A1 72WC*3060A1BAYHTRV110A2WC*3024-060A14WC*3036-060A1BAYSPEK063A BAYHTRV115A 2WC*3030-060A1 7BAYHTRV120A4WC*3036-060A12WC*3048-060A14WC*3048-060A1BAYSPEK064A BAYHTRV315A 4WC*3036-060A3 6BAYHTRV320A4WC*3048-060A3BAYSPEK065A BAYHTRV310A 4WC*3060A3 71 All necessary fuses are included in kitFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.Effective 1/1/06PH-12For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Heat PumpConvertible 2 through 5 TonsWCZ-F – XL 1600WCY-G – XL 1400WCX-G – XL 1200Table PH-13-A — WCZ – XL 1600 Convertible Package Heat PumpCooling Cabinet Supply/Return Supply/Return ShippingUnit Capacity Dimensions (in.) Downflow Horizontal Weight Max SoundModel No. SEER/EER HSPF (Btuh) H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.WCZ – 208-230/1/60WCZ036F100B 15.60/12.00 7.65 36,000 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 588 27.1 40 80 R1/2WCZ060F100B 15.05/10.50 8.10 58,000 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 679 43.5 70 82 R1/2WCZ – 208-230/3/60WCZ036F300B 15.60/12.00 7.65 36,000 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 588 19.6 30 82 R1/2WCZ060F300B 15.05/10.50 8.10 58,000 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 679 30.9 45 82 R1/2Table PH-13-B — WCY-G – XL 1400 Convertible Package Heat PumpCooling Cabinet Supply/Return Supply/Return ShippingUnit Capacity Dimensions (in.) Downflow Horizontal Weight Max SoundModel No. SEER/EER HSPF (Btuh) H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.WCY – 208-230/1/60WCY024G100B 13.70/11.90 7.90 24,500 29 x 36 x 56 (B) 10 x 17 1 /2 18 9 /16 x 11 1 /16 387 15.8 25 80 R1WCY030G100B 13.50/11.50 7.70 30,000 29 x 36 x 56 (B) 10 x 17 1 /2 18 9 /16 x 11 1 /16 398 21.4 30 80 R2WCY036G100B 13.50/11.55 7.95 37,000 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 468 27.4 40 80 R2PHASED OUTWCY042G100B 13.05/11.25 7.80 42,000 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 468 29.6 45 80 R2WCY048G100A 13.75/12.00 7.60 49,000 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 576 38.1 60 84 R2WCY060G100A 13.00/11.35 7.80 60,000 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 574 46.8 60 84 STable PH-13-C — WCX – XL 1200 Convertible Package Heat PumpCooling Cabinet Supply/Return Supply/Return ShippingUnit Capacity Dimensions (in.) Downflow Horizontal Weight Max SoundModel No. SEER/EER HSPF (Btuh) H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.WCX – 208-230/1/60WCX024G100B 12.80/11.50 7.60 25,800 29 x 36 x 56 (A) 10 x 17 1 /2 18 9 /16 x 11 1 /16 387 17.1 25 80 R1WCX030G100B 12.30/11.00 7.60 30,500 29 x 36 x 56 (A) 10 x 17 1 /2 18 9 /16 x 11 1 /16 398 20.4 30 80 R2WCX036G100B 12.30/10.90 7.60 38,000 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 468 25.9 40 80 R2WCX042G100B 12.20/10.60 7.90 42,500 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 468 25.9 40 80 R2WCX048G100A 12.00/10.60 7.60 48,000 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 576 37.2 55 84 R2WCX060G100A 12.00/10.70 8.20 58,500 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 576 45.4 70 84 R2PHASED OUTWCX – 208-230/3/60WCX036G300B 12.30/10.90 7.60 38,000 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 468 17.9 25 80 R2WCX042G300A 12.10/10.60 7.90 42,500 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 468 18.8 30 80 R2WCX048G300A 12.00/10.60 7.60 48,000 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 576 27.8 40 84 R2WCX060G300A 12.00/10.70 8.20 58,500 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 576 30.1 45 84 R2WCX – 460/3/60WCX036G400B 12.30/10.90 7.60 38,000 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 468 9.7 15 80 R2WCX048G400A 12.00/10.60 7.60 48,000 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 576 12.7 15 84 R2WCX060G400A 12.00/10.70 8.20 58,500 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 576 21.1 30 84 R2* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = ScrollFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PH-13 Effective 1/1/06


Package Heat PumpConvertible 1½ through 5 TonsWCP – XE 1200WCC – XE 1000Table PH-14-A — WCP – XE 1200 Convertible Package Heat PumpCooling Cabinet Supply/Return Supply/Return ShippingUnit Capacity Dimensions (in.) Downflow Horizontal Weight Max SoundModel No. SEER/EER HSPF (Btuh) H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.WCP – 208-230/1/60WCP036F100B 12.30/10.9 7.6 38,000 29 x 36 x 62 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 468 25.9 40 80 R2WCP048F100A 12.00/10.6 7.6 48,000 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 576 37.2 55 84 R2WCP060F100A 12.00/10.7 8.2 60,000 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 576 45.4 70 84 R2PHASED OUTWCP048F300A 12.00/10.60 7.6 48,000 33 x 45 x 64 (D) 14 x 20 21 1 /16 x 15 1 /16 576 27.8 40 84 R2WCP – 208-230/3/60WCP036F300B 12.30/10.90 7.6 38,000 29 x 36 x 62 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 468 17.9 25 80 R2WCP060F300A 12.00/10.70 8.2 60,000 33 x 45 x 64 (D) 14 x 20 21 1 /16 x 15 1 /16 576 30.1 45 84 R2WCP – 460/3/60WCP036F400B 12.30/10.90 7.6 38,000 29 x 36 x 62 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 468 9.7 15 80 R2WCP048F400A 12.00/10.60 7.6 48,000 33 x 45 x 64 (D) 14 x 20 21 1 /16 x 15 1 /16 576 12.7 15 84 R2WCP060F400A 12.00/10.70 8.2 60,000 33 x 45 x 64 (D) 14 x 20 21 1 /16 x 15 1 /16 576 17.7 25 84 R2Table PH-14-B — WCC – XE 1000 Convertible Package Heat PumpCooling Cabinet Supply/Return Supply/Return ShippingUnit Capacity Dimensions (in.) Downflow Horizontal Weight Max SoundModel No. SEER/EER HSPF (Btuh) H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.WCC – 208-230/1/60WCC018F100B 10.00/9.60 6.8 18,000 25 x 36 x 55 (A) 10 x 17 1 /2 18 9 /16 x 11 1 /16 337 17.0 25 80 R1WCC024F100B 10.00/9.40 6.8 23,800 25 x 36 x 55 (A) 10 x 17 1 /2 18 9 /16 x 11 1 /16 337 17.7 25 80 R1WCC030F100B 10.00/9.50PHASED6.8 29,800 29 x 36 x 55 (B) 10 x 17 1 OUT/2 18 9 /16 x 11 1 /16 359 23.4 40 80 R1/2WCC036F100B 10.00/9.50 6.8 36,000 29 x 36 x 55 (B) 10 x 17 1 /2 18 9 /16 x 11 1 /16 383 26.0 40 80 R2WCC042F100B 10.00/9.15 6.8 41,500 29 x 36 x 55 (B) 10 x 17 1 /2 18 9 /16 x 11 1 /16 400 31.2 50 80 R2WCC048F100B 10.00/9.50 6.8 48,000 33 x 45 x 64 (D) 14 x 20 21 1 /16 x 15 1 /16 552 37.2 60 84 R2WCC060F100B 10.009.50 6.8 60,000 33 x 45 x 64 (D) 14 x 20 21 1 /16 x 15 1 /16 547 41.1 60 84 R2WCC – 208-230/3/60 - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.WCC036F300B 10.00/9.50 6.8 36,000 29 x 36 x 55 (B) 10 x 17 1 /2 18 9 /16 x 11 1 /16 459 19.4 30 80 R2WCC042F300B 10.00/9.15 6.8 41,500 29 x 36 x 55 (B) 10 x 17 1 /2 18 9 /16 x 11 1 /16 400 23 7 40 80 R2WCC048F300B 10.00/9.50 6.8 48,000 33 x 45 x 64 (D) 14 x 20 21 1 /16 x 15 1 /16 552 28.3 40 84 R2WCC060F300B 10.00/9.50 6.8 60,000 33 x 45 x 64 (D) 14 x 20 21 1 /16 x 15 1 /16 547 31.5 45 84 R2WCC – 460/3/60 - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.WCC036F400B 10.00/9.50 6.8 36,000 29 x 36 x 55 (B) 10 x 17 1 /2 18 9 /16 x 11 1 /16 359 10.2 15 80 R2WCC048F400B 10.00/9.50 6.8 48,000 33 x 45 x 64 (D) 14 x 20 21 1 /16 x 15 1 /16 552 13.8 20 84 R2WCC060F400B 10.00/9.50 6.8 60,000 33 x 45 x 64 (D) 14 x 20 21 1 /16 x 15 1 /16 547 16.3 25 84 R2* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.Note: WCC-F models currently m<strong>an</strong>ufactured with sloped drain p<strong>an</strong>s.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = ScrollEffective 1/1/06For information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.PH-14For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Heat PumpConvertible 1½ through 5 TonsBASPACER PANELWCCO42F ONLYSUPPLY &RETURN PANELEVAPORATOR COIL &BLOWER PANELCORNER POSTCCENTER OFGRAVITYEFEGHECONOMIZER/FILTERACCESS PANELCONDENSOR COILKHORIZONTALSUPPLYOPENINGJ35 MM(1 3/8")DOWNFLOWSUPPLYOPENINGDLPMHORIZONTALRETURN OPENINGDXXLMNYY76 MM(3")29 MM(1 1/8")CONDENSATE DRAIN19 MM (3/4") FEMALE NPTDOWNFLOWRETURN OPENINGTable PH-15-A — WCZ – XL 1600 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0WCZ036F 64 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 18 1 /2 25 17 1 /2 10 3 8 3 /4 33AWCZ060F 65 1 /8 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 22 1 /4 25 20 14 3 1 /2 8 5 /16 34ATable PH-15-B — WCY – XL 1400 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0WCY024G 56 1 /2 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 25 3 /8 17 1 /2 10 3 4 7 /16 30A, 38AWCY030G 56 1 PHASED OUT/2 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 24 3 /8 17 1 /2 10 3 4 7 /16 30A, 38AWCY036G 64 36 29 1 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 19 1 /4 27 1 /2 17 1 /2 10 3 8 3 /4 30A, 38A, 33AWCY042G 64 36 29 1 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 19 1 /4 27 1 /2 17 1 /2 10 3 8 3 /4 30A, 38A, 33AWCY048G 65 1 /4 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 24 1 /4 28 1 /2 20 14 3 1 /2 8 5 /16 30A, 38A, 34AWCY060G 65 1 /4 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 24 1 /4 28 1 /2 20 14 3 1 /2 8 5 /16 30A, 38A, 34ATable PH-15-C — WCX – XL 1200 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0WCX024G 56 1 /2 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 25 3 /8 17 1 /2 10 3 4 7 /16 30A, 38AWCX030G 56 1 PHASED OUT/2 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 24 3 /8 17 1 /2 10 3 4 7 /16 30A, 38AWCX036G 64 36 29 1 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 19 1 /4 27 1 /2 17 1 /2 10 3 8 3 /4 30A, 38A, 33AWCX042G 64 36 29 1 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 19 1 /4 27 1 /2 17 1 /2 10 3 8 3 /4 30A, 38A, 33AWCX048G 65 1 /4 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 24 1 /4 28 1 /2 20 14 3 1 /2 8 5 /16 30A, 38A, 34AWCX060G 65 1 /4 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 24 1 /4 28 1 /2 20 14 3 1 /2 8 5 /16 30A, 38A, 34ATable PH-15-D— WCP – XE 1200 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0WCP036F 62 7 /8 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 19 1 /4 27 1 /2 17 1 /2 10 3 8 3 /4 30A, 38A, 33AWCP048F 64 3 /8 45 33 1 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 24 1 /4 28 1 /2 20 14 3 1 /2 8 5 /16 30A, 38A, 33AWCP060F 64 3 /8 45 33 1 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 24 1 /4 28 1 /2 20 14 3 1 /2 8 5 /16 30A, 38A, 34APHASED OUTTable PH-15-E — WCC – XE 1000 Dimensional Data - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.Model A B C D E F G H J K L M N P BAYCURB0WCC018F 55 1 /4 36 25 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 20 1 /2 25 17 1 /2 10 3 4 7 /16 30A, 38AWCC024F 55 1 /4PHASED36 25 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 20 1 /2OUT25 17 1 /2 10 3 4 7 /16 30A, 38AWCC030F 55 1 /4 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 20 13 /16 25 5 /16 17 1 /2 10 3 4 7 /16 30A, 38AWCC036F 55 1 /4 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 19 24 3 /16 17 1 /2 10 3 4 7 /16 30A, 38AWCC042F 55 1 /4 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 18 13 /16 24 17 1 /2 10 3 4 7 /16 30A, 38AWCC048F 64 5 /16 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 24 3 /4 29 20 14 3 1 /2 8 5 /16 30A, 38A, 34AWCC060F 64 5 /16 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 24 3 /4 29 20 14 3 1 /2 8 5 /16 30A, 38A, 34ANote: WCC-F models currently m<strong>an</strong>ufactured with sloped drain p<strong>an</strong>s.For information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleasePH-15 Effective 1/1/06refer to Product Data <strong>an</strong>d/or Installers Guides.


Package Dual Fuel Heat Pump withAuxiliary Gas HeatDCY• Climatuff® high efficiency compressor• Shipped for horizontal application,easily convertible to downflow• Heavy gauge steel cabinet with weatherresist<strong>an</strong>t, powder paint• Attractive coil guard <strong>an</strong>d trim ring• Direct spark (3-try) ignition• Aluminized steel tubular heat exch<strong>an</strong>ger• Optional filter rack fits inside unit• Ball-bearing induced draft combustionblower• Copper tube, aluminum plate fin coils• Restricted or non-restricted operating mode• Low profile horizontal duct take-offs• One screw convertible to downflow• Built-in downflow duct fl<strong>an</strong>ges• Single curb fits all models• Aluminized multi-port-in-shot burner• Dual firing 20 <strong>an</strong>d 25 MBTUHheat exch<strong>an</strong>gers (optional)• Top discharge condenser f<strong>an</strong>• Comfort-R TM enh<strong>an</strong>ced perform<strong>an</strong>ce onDCY060F models (1ø <strong>an</strong>d 3ø) only• Dem<strong>an</strong>d defrost• Water shed base p<strong>an</strong>• Liquid line filter-drier• High efficiency outdoor f<strong>an</strong> motor withpolarized plug• 2-speed (high for cooling, low for heating)direct-drive blower motor• Internal compressor protection• Protected pressure taps for refriger<strong>an</strong>tchecks• St<strong>an</strong>dard operations to 55°F as m<strong>an</strong>ufactured• Low ambient cooling to 0°F with accessoriesBAYLOAM011ATable PH-16-A — DCY – XL 1200 Convertible Dual Fuel Heat PumpsUnit Cooling Gas Heating Cabinet Supply/Return Supply/Return ShippingModel Capacity Capacity Output SEER/ Dimensions (in.) Downflow Horizontal Weight Max. SoundNo. (Btuh) (Btuh)1 EER AFUE % HSPF H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.DCY – 208-230/1/60DCY024F1L0B 25,800 32 or 38 12.80/11.50 78 7.60 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 446 17.1 25 80 R1DCY030F1M0B 30,400 45 or 57 12.20/11.00 78 7.60 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 471 20.4 30 80 R2DCY036F1H0B 38,000 64 or 80 12.30/10.90 80 7.60 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 486 25.9 40 80 R2DCY048F1H0B 48,000 80 or 98 12.00/10.60 80 7.60 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 628 37.2 55 84 R2DCY060F1M0A 58,500 80 or 98 12.00/10.70 80 8.20 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 628 45.4 70 84 R2PHASED OUTDCY – 208-230/3/60DCY036F3H0B 38,000 64 or 80 12.00/10.90 80 7.60 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 486 17.9 25 80 R2DCY048F3H0B 49,000 80 or 98 12.00/10.60 80 7.60 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 628 27.8 40 84 R2DCY060F3M0A 58,500 80 or 98 12.00/10.70 80 8.20 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 628 30.1 45 84 R2DCY – 460/3/60DCY036F4H0B 38,000 64 or 80 12.00/10.90 80 7.60 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 486 9.7 15 80 R2DCY048F4H0B 49,000 80 or 98 12.00/10.60 80 7.60 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 628 12.7 15 84 R2DCY060F4M0A 58,500 80 or 98 12.00/10.70 80 8.21 33 x 45 x 65 (D) 20 x 14 21 1 /16 x 15 1 /16 628 21.1 30 84 R2Table PH-16-B — AccessoriesModel No. Description Used WithBAYECMT002APHASEDExtreme Conditions Mounting Kit (Curb Mount)OUTAll DCY ModelsBAYECMT003A Extreme Conditions Mounting Kit (Slab or Rack Mount) All DCY ModelsBAYLPKT022A LP Conversion Kit All DCY ModelsBAYLPSS001A LP Conversion Kit w/stainless burners All DCY ModelsAdditional Accessories are listed on page PH-19.1 Unit ships st<strong>an</strong>dard in high heat configuration. Low-fire operation requires optional BAYLOFR001-007 kit..* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = ScrollFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.Effective 1/1/06PH-16For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Heat PumpConvertible 1½ through 5 TonsDCY WCZ WCY-G WCX-G WCP-F WCC-FTable PH-17-A — Features 2-5 3-5 2-5 2-5 3-5 1 1 /2-5• Impack Plus feature set ............................................................................................ — ✔ ✔ ✔ ✔ —• Climatuff® Compressor (2) .......................................................................................... — ✔ — — — —• Climatuff® Compressor (1) .......................................................................................... ✔ — ✔ ✔ ✔ ✔• Comfort “R” mode option .......................................................................................... 5 ✔ ✔ 5 5 —• DuraTuff Plate Fin coil ............................................................................................... ✔ ✔ ✔ ✔ ✔ ✔• Coil Sav’R TM coil guard ................................................................................................. ✔ ✔ ✔ ✔ — —• Cr<strong>an</strong>kcase heater .......................................................................................................... ✔ ✔ ✔ ✔ ✔ ✔• Deluxe XL Lex<strong>an</strong> nameplate .......................................................................................... ✔ ✔ ✔ ✔ ✔ —• Dem<strong>an</strong>d defrost control with Lite Port/Stored diagnostics ............................................. ✔ ✔ ✔ ✔ ✔ ✔• GE ECM variable speed f<strong>an</strong> w/potted motor module ..................................................... 5 ✔ ✔ 5 5 —• Horizontal convertible to downflow ................................................................................ ✔ ✔ ✔ ✔ ✔ ✔• Polarized plugs .............................................................................................................. ✔ ✔ ✔ ✔ ✔ ✔• Powder paint .................................................................................................................. ✔ ✔ ✔ ✔ ✔ ✔• Time/temperature defrost .............................................................................................. — — — — — ✔• Two-stage cooling .......................................................................................................... — ✔ — — — —• Two-stage heating .......................................................................................................... — ✔ ✔ — — —• 5-year limited compressor only warr<strong>an</strong>ty (Commercial use) .......................................... ✔ ✔ ✔ ✔ ✔ ✔• 5-year limited heat exch<strong>an</strong>ger warr<strong>an</strong>ty (Commercial use) ........................................... ✔ — — — — —• 5-year limited compressor <strong>an</strong>d coil warr<strong>an</strong>ty (<strong>Residential</strong> use) ..................................... — — — — — ✔• 5-year limited parts warr<strong>an</strong>ty (<strong>Residential</strong> use) ............................................................. ✔ ✔ ✔ ✔ — —• 5-year limited parts warr<strong>an</strong>ty (<strong>Residential</strong> use) ............................................................. — — — — — ✔• 1-year limited coil <strong>an</strong>d parts warr<strong>an</strong>ty (Commercial use) .............................................. ✔ ✔ ✔ ✔ ✔ ✔• 10-year limited compressor <strong>an</strong>d coil warr<strong>an</strong>ty (<strong>Residential</strong> use) ................................... ✔ — — — — —• 10-year limited compressor <strong>an</strong>d outdoor coil warr<strong>an</strong>ty (<strong>Residential</strong> use) ...................... ✔ ✔ ✔ ✔ — —• 20-year heat exch<strong>an</strong>ger warr<strong>an</strong>ty (<strong>Residential</strong> use) ...................................................... ✔ — — — — —PHASED OUTPHASED OUTTable PH-17-B — Comfort ControlsBAY28X138A ........... Auto 2-Stage Heating/1-Stage Cooling ............................................. ✔ ✔ ✔ ✔BAY28X153A ........... Auto 3-Stage Heating/2 Stage Cooling ............................................. ✔ ✔ ✔ ✔BAY28X1901 ........ Locking Thermostat Cover ................................................................ ✔ ✔ ✔ ✔BAY41X1711 ........ 5 or 7 Minute Delay Relay ................................................................. ✔ ✔ ✔ ✔BAYASCT001A1 ....... Anti-short Cycle Timer ...................................................................... — — — —BAYSTAT033A ......... Outdoor Thermostat ......................................................................... ✔ ✔ ✔ ✔BAYSTAT040B3 ...... Prog. Electronic Setback 3 Htg/2 Clg ................................................ ✔ — — —BAYSTAT239A ......... M<strong>an</strong>ual 2-Stage Heating/1 Cooling ................................................... ✔ ✔ ✔ ✔BAYSTAT240A ......... M<strong>an</strong>ual 2 Heating/1 Cooling with Subbase ........................................ ✔ ✔ ✔ ✔BAYSTAT253A ......... Humidity Control ............................................................................... — — — —TAYSENS100A ........ Outdoor Temp. Sensor (with case) .................................................... ✔ ✔ ✔ ✔TAYSTAT500C ......... XT 500C M<strong>an</strong>ual Prog. 3 Htg/2 Clg ................................................... ✔ ✔ ✔ ✔TAYSTAT540 ............ Prog.,5/2 Day, M<strong>an</strong>ual ...................................................................... ✔ ✔ ✔ ✔TAYSTAT570 ............ Electronic, 2Htg/1Clg (Non Prog.) ..................................................... ✔ — — —PHASED OUTTAYSTAT575 ............ Electronic, 3Htg/2Clg (Non Prog.) ..................................................... ✔ — ✔ ✔TCONT402A ............ 3Htg/2Clg (Heat Pump/A/C) ............................................................. ✔ ✔ ✔ ✔TCONT602A ............ 2Htg/2Clg (Heat Pump/A/C) ............................................................. ✔ ✔ ✔ ✔TCONT802A ............ 3Htg/2Clg (Heat Pump/A/C) ............................................................. ✔ ✔ ✔ ✔TCONT803A ............ 3Htg/2Clg (Heat Pump/A/C) w/Humidity Control ............................... ✔ ✔ ✔ ✔1 Not for use with programmable thermostats.2 Subbase used with BAYSTAT040B.3 Use with BAYBASE007A.See Comfort Controls/Zone Sensors SectionSee Comfort Controls/Zone Sensors SectionPHASED OUTFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PH-17 Effective 1/1/06


Package Heat PumpConvertible 1½ through 5 TonsTable PH-18-A — Supplementary Heaters – Single Point Entry Kit/Heater MatrixUsed With SingleUsed WithModel No. Description Power Entry Kit12Packaged Heat Pump UnitBAYHTRN105A ... 3.74/4.98 kW Heater (208/240V 1PH) ....... BAYSPEK047A ..... WCC018-042F1, WCY024-042G1, WCX024-042G1,WCZ036F1BAYHTRN108A ... 5.76/7.68 kW Heater (208/240V 1PH) ....... BAYSPEK047A ..... WCC018-024F1, WCY/WCX024G1BAYSPEK049A ..... WCC030-042F1,WCY030-042G1,WCX030-042G1,WCZ036F1BAYHTRN110A ... 7.47/9.96 kW Heater (208/240V 1PH) ....... BAYSPEK049A ..... WCC024-048F1, WCY024-048G1 ,WCX024-048G1, WCZ036F1BAYSPEK053A ..... WCC/WCZ060F1, WCY060G1,WCX060G1BAYHTRN112A ... 8.65/11.52 kW Heater (208/240V 1PH) ..... BAYSPEK049A ..... WCC024-048F1, WCY024-048G1,WCX024-048G1, WCZ036F1BAYSPEK053A ..... WCC/WCZ060F1,WCY060G1, WCX060G1BAYHTRN115A ... 11.21/14.94 kW Heater (208/240V 1PH) .... BAYSPEK048A ..... WCC030-048F1, WCY030-048G1, WCX030-048G1, WCZ036F1BAYSPEK052A ..... WCC/WCZ060F1, WCY060G1, WCX060G1BAYHTRN117A ... 12.98/17.28 kW Heater (208/240V 1PH) .... BAYSPEK048A ..... WCC030-048F1, WCY030-048G1, WCX030-048G1, WCZ036F1BAYSPEK052A ..... WCC/WCZ060F1, WCY060G1, WCX060G1BAYHTRN123A ... 17.2/23.04 kW Heater (208/240V 1PH) ..... BAYSPEK048A ..... WCC048F1, WCY048G1, WCX048G1BAYSPEK052A ..... WCC/WCZ060F1,WCY/ WCX060G1BAYHTRN306A ... 4.89/6.25 kW Heater (208/240V 3PH) ....... BAYSPEK047A ..... WCC/WCZ036-060F3, WCX036-060G3BAYHTRN310A ... 7.45/9.96 kW Heater (208/240V 3PH) ....... BAYSPEK047A ..... WCC/WCZ036F3, WCP036 - 060F3, WCX036G3BAYSPEK051A ..... WCZ060F3BAYHTRN310F ... 7.45/9.96 kW Heater (208/240V 3PH) ....... BAYSPEK051A ..... WCZ060F3, WCX/WCY036-060G3, WCP036-060F3BAYSPEK047 ........ WCZ036F3BAYHTRN315A ... 11.25/14.90 kW Heater (208/240V 3PH) .... BAYSPEK051A ..... WCC/WCZ036-060F3, WCX036-060G3, WCP036-060F3BAYHTRN320A ... 14.96/19.92 kW Heater (208/240V 3PH) .... BAYSPEK051A ..... WCC042-060F3, WCX042-060G3, WCZ060F3,WCP042-060F3BAYHTRN330A ... 22.41/29.80 kW Heater (208/240V 3PH) .... BAYSPEK050A ..... WCC/WCZ060F3, WCX060G3, WCP060F3BAYHTRN406A ... 6kW Heater (480V 3PH) .......................... BAYSPEK047A ..... WCC/WCP036-060F4, WCX036-060G4BAYHTRN410A ... 9.96 kW Heater (480V 3PH) ..................... BAYSPEK047A ..... WCC036-060F4, WCP036-060F4, WCX036-060G4BAYHTRN410F ... 9.96 kW Heater (460V 3PH) ..................... BAYSPEK047A ..... WCP036-060F4, WCX036-060G4BAYHTRN415A ... 14.90 kW Heater (480V 3PH) ................... BAYSPEK047A ..... WCC036-060F4, WCP036-060F4, WCX036-060G4BAYHTRN420A ... 19.92 kW Heater (480V 3PH) ................... BAYSPEK047A ..... WCC048-060F4, WCP048-060F4, WCX048-060G4BAYHTRN430A ... 29.80 kW Heater (480V 3PH) ................... BAYSPEK047A ..... WCC060F4, WCP060F4, WCX060G41 All necessary fuses are included in kit.2 Relay required with economizer on WCZ-F models.For information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.Effective 1/1/06PH-18For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Heat PumpConvertible 1½ through 5 TonsDCY WCZ WCY-G WCX WCP WCCTable PH-19-A — Accessories 2-5 3-5 2-5 2-5 3-5 1½-5BAY24X045 ......... Indoor F<strong>an</strong> Delay Kit .................................................................................. — — — 2-5 3-5 1 1 /2-5BAYASCT00168 Anti-Short Cycle Timer ............................................................................... 2-5 3-5 2-5 2-5 3-5 1 1 /2-5BAYCURB030A ... Roof Curb (Flat Roof)3 (14 H x 34 W x 53 1 /8 L) .......................................... 2-5 3-5 2-4 2-5 3-5 1 1 /2-5BAYCURB033A ... Roof Curb (Flat Roof)3 Acousti-Curb (14 H x 34 W x 60 5 /8 L) .................... 2-3 3 3 3 1 /2 3 1 /2 —BAYCURB034A ... Roof Curb (Flat Roof)3Acousti-Curb (14 H x 43 W x 62 1 /16 L) .................... 4-5 5 4-5 4-5 4-5 4-5BAYCURB038A ... Roof Curb (Flat Roof)3 Acousti-Curb (14 H x 34 W x 53 1 /8 L) .................... 2-5 3-5 2-4 2-5 3-5 1 1 /2-5BAYDMPR040A ... 0-25% M<strong>an</strong>ual Fresh Air Damper (Downflow Only)2 ................................ 2-3 3 2-3 1 /2 2-3 1 /2 3 1 1 /2-3 1 /2BAYDMPR041A ... 0-25% M<strong>an</strong>ual Fresh Air Damper (Downflow Only)2 ................................ 4-5 5 4-5 4-5 4-5 4-5BAYDMPR050A ... Motorized Fresh Air Damper ...................................................................... 4-5 — 4-5 4-5 4-5 4-5BAYDUCT004A ... 12" Round Duct Adapters (2 per Box) ....................................................... 2-3 3 2-3 1 /2 2-3 1 /2 3 1 1 /2-3 1 /2BAYDUCT005A ... 14" Round Duct Adapters (1 per Box) ....................................................... 2-3 3 2-3 1 /2 2-3 1 /2 3 1 1 /2-3 1 /2BAYECMT002A ... Extreme Conditions Mounting Kit (Curb Mount) ......................................... 2-5 3-5 2-5 2-5 3-5 1 1 /2-5BAYECMT003A ... Extreme Conditions Mounting Kit (Slab or Rack Mount) ............................. 2-5 3-5 2-5 2-5 3-5 1 1 /2-5BAYECON054B ... 0-100% Mod. Downflow Economizer with Bar Relief1245 ..................... 2-3 3 2-3 1 /2 2-3 1 /2 3 1 1 /2-3 1 /2BAYECON055B ... 0-100% Mod. Downflow Economizer with Bar Relief1245 ..................... 4-5 5 4 -5 4-5 4-5 4-5BAYECON073A ... 0-100% Mod. Horizontal Economizer1245 ............................................ 2-5 3-5 2-5 2-5 3-5 1 1 /2-5BAYENTH001A ... Enthalpy Control (Solid State)4 ................................................................ 2-5 3-5 2-5 3-5 3-5 1 1 /2-5BAYFLTR012A ..... Filter Frame2 (20 x 25 x 1" filter not included) ........................................... — — 2-2 1 /2 2-2 1 /2 — 2 1 /2-3 1 /2BAYFLTR013A ..... Filter Frame2 (20 x 25 x 1" filter not included) ........................................... 2-3 3 3-3 1 /2 3-3 1 /2 3 —BAYFLTR014A ..... Filter Frame2 (3-10 x 25 x 1" filter not included) ........................................ 4-5 5 4-5 4-5 4-5 4-5BAYFLTR015A ..... Filter Frame2 (20 x 20 x 1" filter not included) ........................................... — — — — — 1 1 /2-2BAYFLTR017A ..... Filter Frame2 (1-20 x 25 x 2" filter not included) ........................................ — — 2-2 1 /2 2-2 1 /2 — 2 1 /2-3 1 /2BAYFLTR018A ..... Filter Frame2 (1-20 x 25 x 2" filter not included) ........................................ 2-3 3 3-3 1 /2 3-3 1 /2 3 —BAYFLTR019A ..... Filter Frame2 (2-16 x 25 x 2" filter not included) ........................................ 4-5 5 4 4-5 4-5 4-5BAYGARD016A ... Condenser Coil Guard ............................................................................... — — — — — 1 1 /2-2BAYGARD017A ... Condenser Coil Guard ............................................................................... — — — — — 2 1 /2-3BAYGARD019A ... Condenser Coil Guard ............................................................................... — — — — — 3 1 /2BAYGARD022A ... Condenser Coil Guard ............................................................................... — — — — — 4-5BAYHSMT043A ... High Static Motor (230/460) 3/4HP ............................................................ 2 1 /2-3 — — 2 1 /2-3 1 /2 2 1 /2-3 2 1 /2-3 1 /2BAYHSMT044A ... High Static Motor (230/460) 1HP ............................................................... 4 — — 4 4 4-5BAYHSMT045A ... High Static Motor (208) 1HP ...................................................................... 4 — — 4 4 4-5BAYHSMT056A ... High Static Motor (208) 3/4HP ................................................................... 2 1 /2-3 — — 2 1 /2-3 1 /2 3 2 1 /2-3 1 /2BAYINDK001A* ... Insulated Deck P<strong>an</strong> for A & B Cabinet ........................................................ — — 2-2 1 /2 2-2 1 /2 — 1 1 /2-3BAYINDK002A** .. Insulated Deck P<strong>an</strong> for C Cabinet .............................................................. 2-3 3 3-3 1 /2 3-3 1 /2 3 —BAYINDK003A*** . Insulated Deck P<strong>an</strong> for D Cabinet .............................................................. 4-5 5 4-5 4-5 4-5 4-5BAYKSKT010A .... Quick Start Kit (Single Phase Units Only) ................................................. — — — — — 1 1 /2-5BAYLIFT002B ...... Lifting Lug Kit ............................................................................................ 2-5 3-5 2-5 2-5 3-5 1 1 /2-5BAYLOAM011A ... Evaporator Defrost Control Kit ................................................................... 2-5 3-5 2-5 2-5 3-5 1 1 /2-5BAYLOAM323A ... Dual Voltage Electronic Head Pressure Control7 (use w/BAYRLAY005) ........... 2-5 — 2-5 2-5 3-5 1 1 /2-5BAYLOFR001 ...... Low Fire Kit ................................................................................................ 2 — — — — —BAYLOFR004 ...... Low Fire Kit ................................................................................................ 2 1 /2 -3 — — — — —BAYLOFR005 ...... Low Fire Kit ................................................................................................ 3 — — — — —BAYLOFR007 ...... Low Fire Kit ................................................................................................ 4-5 — — — — —BAYLPKT022A .... LP Conversion Kit ...................................................................................... 2-5 — — — — —BAYLPSS001A .... LP Conversion Kit with SS Burners ............................................................ 2-5 — — — — —BAYMOTR307A ... 200-230V 1/2HP OD F<strong>an</strong> Motor (use w/BAYLOAM323A&BAYRLAY005) .......... 2-5 — 2-5 2-5 3-5 1 1 /2-5BAYMOTR406A ... 460V 1/2HP Outdoor F<strong>an</strong> Motor (use w/BAYLOAM323A&BAYRLAY005) ......... 3-5 — — 3-5 3-5 3-5BAYOSAC001A ... Outside Air Controller ............................................................................. — 3-5 — — — —BAYRLAY002 ....... Time Delay Relay ..................................................................................... — — 2-5 2-5 2-5 —BAYRLAY004A .... Economizer Relay Kit1 ............................................................................. 2-5 3-5 2-5 2-5 3-5 1 1 /2-5BAYRLAY005A7 . Relay Required with BAYLOAM323A8 ...................................................... 2-5 — 2-5 2-5 3-5 1 1 /2-5BAYSTAT023 ....... Remote Potentiometer for All Economizers ................................................ 2-5 3-5 2-5 2-5 3-5 1 1 /2-5BAYUTIL030A ..... Roof Curb Utility Extension Kit for BAYCURB030, 038A ............................ — — — — — 1 1 /2-5BAYUTIL034A ..... Roof Curb Utility Extension Kit for BAYCURB034A .................................... — — — — — 4-51 BAYRLAY004A required with economizer.2 Must use filter frame when economizer/fresh air kit is used.3 Ships knocked down.4 Dry bulb control st<strong>an</strong>dard with economizer.5 2-Stage thermostat provides additional energy savings if simult<strong>an</strong>eouseconomizer <strong>an</strong>d compressor operation is expected.6 Do not use with programmable thermostats.7 May require motor ch<strong>an</strong>ge. (See Installers Guide.)8 Activated on Power On.PHASED OUT PHASED OUT* Currently Shipped with BAYCURB038A.** Currently Shipped with BAYCURB033A.*** Currently Shipped with BAYCURB034A.PHASED OUTFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PH-19 Effective 1/1/06


Package Heat Pump2 through 3½ TonsTable PC-20-A — XE 1200 — Cooling w/5/10-15 kW Electric Heat - Single Phase (208/230/1/60)Cooling Dimensions Round Round ShippingUnit Capacity (in.) Supply Return Weight SoundTons Model No. SEER/EER (Btuh) H x W x L Opening Opening (Ibs.) Rating Compressor2 WCK024A100A 12.50/11.00 25,000 31 x 32 x 44 (**) 14" 14" 348 73 R12 1 /2 WCK030A100A 12.30/10.75 30,500 31 x 32 x 44 (**) 14" 14" 350 73 S3 WCK036A100A 12.75/10.70 36,000 31 x 32 x 44 (**) 14" 14" 370 73 S3 1 /2 WCK042A100A 12.00/10.50 42,000 31 x 32 x 44 (**) 14" 14" 372 73 SEffective 1/1/06WCK• Climatuff ® compressor• Compressor motor overload protection• Internal pressure relief valve• Dem<strong>an</strong>d Defrost Control w/Lite Port/StoredDiagnostics• Copper tube, aluminum plate fin coils• Static (0.5") ESP Indoor Blower System withtwo-speed blower motor• Shaft-Down OD f<strong>an</strong> system for quiet operation(good neighbor)PH-20• Sloped composite drain p<strong>an</strong>• Waterproof closed-cell foam evaporator baseinsulation• Heavy gauge steel cabinet• Weather resist<strong>an</strong>t Powder Paint• Double powder painted G90 base p<strong>an</strong> withdimpled feet• Wrap-around vinyl-coated wire coil guards• U.L. listed• 5-year limited warr<strong>an</strong>ty on compressor <strong>an</strong>d5-year on all other parts (<strong>Residential</strong> use)• Optional extended warr<strong>an</strong>tiesTable PC-20-B — Electric Heater DataUSING SINGLE SUPPLY CIRCUITHEATER ONLYWCK HEAT PUMPSUPPLY CIRCUITUnitModelMax. Fuse C<strong>an</strong>da Max. Fuse C<strong>an</strong>daElectricRatedHeateror HQCR Only Max. or HQCR Only Max.HeaterVoltageKw MCA (2)CKT BKR CKT BKRMCA (7)CKT BKR CKT BKRModel 208/240Size (4) Size (5) Size (4) Size (5)NONE** 208/240 NONE** 17/17(3) 25/25 25/25 NONE NONE NONEWCK024A1 (6) BAYHTRK105A 208/240 3.74/4.98 40/43(3) 45/45 50/50 23/26 25/30 25/30BAYHTRK111A 208/240 7.47/9.96 62/70(3) 70/70 70/70 45/53 45/60 50/60NONE** 208/240 NONE** 21/21(3) 30/30 30/30 NONE NONE NONEWCK030A1 (6) BAYHTRK105A 208/240 3.74/4.98 44/47(3) 50/50 50/50 23/26 25/30 25/30BAYHTRK110A 208/240 7.47/9.96 66/73(3) 70/80 70/100 45/53 45/60 50/60NONE** 208/240 NONE** 25/25(3) 40/40 40/40 NONE NONE NONEWCK036A1 (6)BAYHTRK105A 208/240 3.74/4.98 48/51(3) 50/60 50/60 23/26 25/30 25/30BAYHTRK110A 208/240 7.47/9.96 70/77(3) 70/80 70/100 45/53 45/60 50/60BAYHTRK115A 208/240 11.18/14.94 93/103(3) 100/110 100/110 58/78 70/80 70/100NONE** 208/240 NONE** 28/28(3) 45/45 45/45 NONE NONE NONEWCK042A1 (6)BAYHTRK105A 208/240 3.74/4.98 51/54(3) 60/60 60/60 23/26 25/30 25/30BAYHTRK110A 208/240 7.47/9.96 73/80(3) 80/80 100/100 45/53 45/60 50/60BAYHTRK115A 208/240 11.18/14.94 96/106(3) 100/110 100/125 68/78 70/80 70/100** Unit electrical information with no electric heat installed.1. Any power supply <strong>an</strong>d circuits must be wired <strong>an</strong>d protected inaccord<strong>an</strong>ce with local electrical codes.2. The MCA values listed are for electric heater <strong>an</strong>d heat pump unit.3. Field wire must be rated at least 75°C.4. The HACR circuit breaker is for U.S.A. installations only.5. For C<strong>an</strong>ada installation reference only.6. BAYHTR111A only approved for WCK024A1.7. The MCA values listed are for electric heater only.Table PC-20-C — Accessories/Comfort ControlsModel No. Description Used WithBAY28X1842 Subbase Auto/M<strong>an</strong>. Ch<strong>an</strong>geover BAY28X183BAY28X1853 Subbase M<strong>an</strong>. Ch<strong>an</strong>geover BAY28X182,183BAY28X1872 Subbase Auto Ch<strong>an</strong>geover BAY28X182,183BAYECMT002A Extreme Conditions Mounting Kit (Curb Mount) All WCK ModelsBAYECMT003A Extreme Conditions Mounting Kit (Slab or Rack Mount) All WCK ModelsBAYCOVR100A Wallcover Plate TAYSTAT371TAYSENS100A Outdoor Temperature Sensor (with case) TAYSTAT300TCONT402A 3Heat/2Clg (Heat Pump/A/C) All WCK ModelsTCONT602A 2Heat/2Clg (Heat Pump/A/C) All WCK ModelsTCONT802A 3Heat/2Clg (Heat Pump/A/C) All WCK ModelsTCONT803A 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control All WCK ModelsA/M = Automatic or M<strong>an</strong>ual Ch<strong>an</strong>geover1 Requires subbase.2 Requires BAY24X042 relay when used with electric heaters.3 Specially designed for electric heater application (inst<strong>an</strong>t on f<strong>an</strong>).* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.WCK models will be upgraded in the 1st Quarter of 2006.For information on Roof Curbs <strong>an</strong>dRoof Curb Adaptors, please refer tothe Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Heat PumpOver/Under 2 through 5 Tons• Climatuff® compressor• Over(Supply)/Under (Return) air configuration• Electric heat accessory fits inside unit casingfor lower installation cost• Electronic time/temperature defrost controlsystem• Dem<strong>an</strong>d Defrost Control w/Lite Port/storeddiagnostics• Powder paint• Top discharge – quieter operation• 5-year limited compressor warr<strong>an</strong>ty• 5-year limited coil <strong>an</strong>d parts warr<strong>an</strong>ty• Variable speed direct drive blower motor onWCH048-060F modelsWCHTable PH-21-A — WCH – Over/Under Horizontal UnitUnit Power Supply Nom. Cap. Dimensions ShippingModel Volts/ Cooling (in.) Weight Max SoundNo. Phase/Hz SEER/EER HSPF (Btuh) H x W x L (lbs.) MCA* Fuse* Rating Comp.Single PhaseWCH024B100C 208-230/1/60 12.40/10.80 8.0 24,500 30 3 /8 x 31 5 /8 x 44 324 17.2 25 79 R1WCH030B100C 208-230/1/60 12.05/10.80 7.7 30,500 30 3 /8 x 31 5 /8 x 44 343 19.3 30 79 R2WCH036B100C 208-230/1/60 12.05/10.50 8.0 36,400 30 3 /8 x 31 5 /8 x 44 378 25.1 40 79 R2WCH042B100C 208-230/1/60 12.05/10.70 8.0 40,500 30 3 /8 x 31 5 /8 x 44 378 25.1 40 79 R2WCH048F100A 208-230/1/60 13.50/12.00 8.0 49,000 33 1 /8 x 45 x 58 447 37 50 84 SWCH060F100A 208-230/1/60 13.00/11.30 8.2 60,000 33 1 /8 x 45 x 58 457 47 60 84 STons Supply H x W Return H x W2 – 3 1 /2 8 3 /8 x 27 3 /8 16 3 /4 x 27 3 /84 – 5 8 1 /2 x32 1 /32 19 15 /16 x 32 1 /32Table PH-21-B — WCH – Over/Under Horizontal UnitUnit Power Supply Nom. Cap. Dimensions ShippingModel Volts/ Cooling (in.) Weight Max SoundNo. Phase/Hz SEER/EER HSPF (Btuh) H x W x L (lbs.) MCA* Fuse* Rating Comp.Three PhaseWCH036B300C 208-230/3/60 12.05/10.50 7.4 36,000 30 3 /8 x 31 5 /8 x 44 378 17.8 25 82 R2WCH042B300C 208-230/3/60 12.05/10.70 7.5 41,000 30 3 /8 x 31 5 /8 x 44 378 19.4 30 82 R2WCH036B400C 460/3/60 12.05/10.50 7.4 36,000 30 3 /8 x 31 5 /8 x 44 378 9.7 15 82 R2WCH042B400C 460/3/60 12.05/10.70 7.5 41,000 30 3 /8 x 31 5 /8 x 44 378 10.7 15 82 R2Tons Supply H x W Return H x WWCH models will be upgraded in3 – 3 1 /2 8 3 /8 x 27 3 /8 16 3 /4 x 27 3 /8the 1st Quarter of 2006.Dimensions are in inches. See Outline Dimensions.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll422mm[16-5/8]311mm[12-1/4]LEFT SIDERIGHT SIDEFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PH-21 Effective 1/1/06


Package Heat PumpOver/Under 2 through 5 TonsTable PH-22-A— Supplementary Heaters – Heater MatrixModel No. Power Supply kW Ratings Used WithBAYHTRC106A 208/240/1/60 4.33/5.76 kW WCH024-042B100B, 048F1, 060F1BAYHTRC108A 208/240/1/60 6.12/8.16 kW WCH024-042B100BBAYHTRC110A 208/240/1/60 7.93/10.56 kW WCH048F1 onlyBAYHTRC111A 208/240/1/60 7.98/10.56 kW WCH024-042B100B, 060F1BAYHTRC112A 208/240/1/60 8.65/11.52 kW WCH024-042B100BBAYHTRC117A 208/240/1/60 12.98/17.28 kW WCH030-042B100B, 048F1, 060F1Model No. Power Supply kW Ratings Nominal BTUH No. of Stages Used WithBAYHTRC306A 208/240/3/60 4.33/5.76 14,800/19,700 1 WCH036-042B300BBAYHTRC312A 208/240/3/60 8.65/11.52 29,500/39,300 1 WCH036-042B300BBAYHTRC317A 208/240/3/60 12.98/17.28 44,300/59,000 1 WCH036-042B300BBAYHTRC406A 480/3/60 5.76 19,700 1 WCH036-042B400BBAYHTRC412A 480/3/60 11.52 39,300 1 WCH036-042B400BBAYHTRC417A 480/3/60 17.28 59,000 1 WCH036-042B400BTable PH-22-B — Accessories/Comfort ControlsModel No. Description Used WithBAY28X138A ....................... 2-Stg. Heat/1-Stg. Cool Auto. Thermostat ..........................................All WCH ModelsBAY28X153A ....................... Auto. 3 Stg. Htg./2 Stg Clg. ................................................................All WCH ModelsBAYASCT00114 ............... Anti-Short Cycle Timer ...................................................................... All WCH ModelsBAYBASE007A3 ............... 3-Heat/2-Cool Heat Pump ................................................................. BAYSTAT040BBAYECMT002A ................... Extreme Conditions Mounting Kit (Curb Mount) ................................All WCH ModelsBAYECMT003A ................... Extreme Conditions Mounting Kit (Slab or Rack Mount) ....................All WCH ModelsBAYLOAM011A ................... Low Ambient Cooling Kit ...................................................................All WCH ModelsBAYSTAT033A ..................... Outdoor Thermostat ..........................................................................All WCH ModelsBAYSTAT040B ..................... Programmable (used with BAYBASE) ...............................................All WCH ModelsBAYSTAT239A ..................... 2-Stg. Heat/1-Stg. Cool M<strong>an</strong>ual Thermostat ...................................... All WCH ModelsBAYSTAT240A ..................... M<strong>an</strong>ual 2 Heat/1 Cool with Subbase ................................................. All WCH ModelsTAYASCT501A4 ................. 5 minute delay relay ..........................................................................All WCH ModelsTAYSENS100A .................... Outdoor Temp. Sensor .......................................................................TAYSTAT500CTAYSTAT500C ..................... XT500C Prog.,7 Day, M<strong>an</strong>/Auto ........................................................All WCH ModelsTAYSTAT540 ....................... Prog.,5/2 Day, M<strong>an</strong>ual .......................................................................All WCH ModelsTAYSTAT570 ....................... Electronic, 2Htg/1Clg (Non Prog.) .....................................................All WCH ModelsTCONT402A ........................ 3Heat/2Clg (Heat Pump/A/C) ............................................................ All WCH ModelsTCONT602A ........................ 2Heat/2Clg (Heat Pump/A/C) ............................................................ All WCH ModelsTCONT802A ........................ 3Heat/2Clg (Heat Pump/A/C) ............................................................ All WCH ModelsTCONT803A ........................ 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control ............................. All WCH Models1 Not for use with programmable thermostats.2 BAYSENS026A must be used with BAYSENS025A.3 Subbase used with BAYSTAT040B.4 Activated on Power Off.* Heaters must have <strong>an</strong> “A” in eleventh digit to work on WCH models.For information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.Effective 1/1/06PH-22For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package HP M<strong>an</strong>ufacturedHousing – 2½ through 3½ TonsWCM• Climatuff® compressor• High efficiency perform<strong>an</strong>ce• Two-speed evaporator blower motor• Round duct connections for m<strong>an</strong>ufacturedhousing applications• Quiet operating top condenser air discharge• Copper tube/aluminum fin coils• Totally enclosed, perm<strong>an</strong>ently lubricatedcondenser f<strong>an</strong> motor• Hermetically sealed compressor withinternal relief valve• Fully charged R-22 system• Sloped Drain P<strong>an</strong>• Liquid line filter-drier• Heating exp<strong>an</strong>sion device/cooling FCCV• Cr<strong>an</strong>kcase heater• Protected pressure taps for refriger<strong>an</strong>tchecks• Heavy gauge steel cabinet with weatherresist<strong>an</strong>t, baked enamel finish• Fully insulated air h<strong>an</strong>dling compartment• Convenient access p<strong>an</strong>els• 5-year limited compressor <strong>an</strong>d coil warr<strong>an</strong>ty(Residental)• 5-year limited parts warr<strong>an</strong>ty(Residental)• 5-year compressor only limited warr<strong>an</strong>ty(Commercial)• 1-year limited parts warr<strong>an</strong>ty (Commercial)Table PH-23-A — Mobile Home Heat Pumps (208-230/1/60)Unit Cooling Dimensions Round Round ShippingModel Capacity (in.) Supply Return Weight Max SoundNo. SEER/EER (Btuh) H x W x L Opening Opening (Ibs.) MCA* Fuse* Rating Comp.WCM030F100B 10.0/9.50PHASED29,800 29 x 36 x 55 (B) 12 12OUT376 23.4 35 80 R1WCM036F100B 10.0/9.50 36,000 29 x 36 x 55 (B) 12 12 406 26.0 40 80 R2WCM042F100B 10.09.20 41,500 29 x 36 x 55 (B) 14 14 416 31.8 50 80 R2Table PH-23-B — Supplementary Heaters – Separate Power Source/Power Entry RequiredModel No. Description Used WithBAYHTRN105A 3.74/4.98 kW Heater (208/240 volts) All WCM-F ModelsPHASED OUTBAYHTRN108A 5.76/7.68 kW Heater (208/240 volts) All WCM-F ModelsBAYHTRN110A 7.47/9.96 kW Heater (208/240 volts) All WCM-F ModelsBAYHTRN112A 8.65/11.52 kW Heater (208/240 volts) All WCM-F ModelsBAYHTRN115A 11.21/14.94 kW Heater (208/240 volts) All WCM-F ModelsBAYHTRN117A 12.98/17.28 kW Heater (208/240 volts) All WCM-F ModelsTable PH-23-C — AccessoriesModel No. Description Used WithBAYECMT002A Extreme Conditions Mounting Kit (Curb Mount) All WCM ModelsPHASED OUTBAYECMT003A Extreme Conditions Mounting Kit (Slab or Rack Mount) All WCM ModelsBAYFLTR012A Filter Frame (20 x 25 x 1" filter not included) All WCM-F ModelsBAYGARD017A Condenser Coil Guard WCM030, 036FBAYGARD019A Condenser Coil Guard WCM042FBAYHSMT043A High Static Motor All WCM-F ModelsBAYKSKT010A Quick Start Kit All WCM-F ModelsTable PH-23-D — Comfort ControlsModel No. Description Used WithBAY28X138A Auto Ch<strong>an</strong>geover All WCM ModelsBAYSTAT033A Outdoor Thermostat All WCM ModelsBAYSTAT239A M<strong>an</strong>ual Heat Pump All WCM ModelsTAYSTAT500C XT 500C M<strong>an</strong>ual Programmable 3 Htg/2 Clg All WCM ModelsTCONT402A 3Heat/2Clg (Heat Pump/A/C) All WCM ModelsPHASED OUTTCONT602A 2Heat/2Clg (Heat Pump/A/C) All WCM ModelsTCONT802A 3Heat/2Clg (Heat Pump/A/C) All WCM ModelsTCONT803A 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control All WCM Models* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = ScrollFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PH-23 Effective 1/1/06


Precedent 3-10 tonPackaged Heat PumpsFeaturingA New Look for a New CenturyBeveled TopSmoother DesignSmall compact cabinetRecessed access h<strong>an</strong>dlesSt<strong>an</strong>dard Features:• <strong>Tr<strong>an</strong>e</strong> built scroll compressors on all 4-10 ton units. 3 ton unit has a ReciprocatingCompressor• ReliaTel Controls (See page PC-35 for ReliaTel Control Information)• Colored <strong>an</strong>d numbered wiring• Provisions for through the Base Condensate Drain Connections• Patented Hybrid Condenser Coil for easy cle<strong>an</strong>ing• 1" throwaway filters provided on 3-5 ton units• 2" throwaway filters provided on 6-10 ton units• Liquid Line Refriger<strong>an</strong>t Drier• Operating Charge of R-22• IAQ Sloped Drain P<strong>an</strong>s• Single point power for electric Heat• Low Ambient cooling to 0°F• 5 - year Limited Compressor Warr<strong>an</strong>ty• 1 - year Limited Parts Warr<strong>an</strong>tyAdded Flexibility• Convertible airflow• Fork lift openings on three sides of unit• Direct or belt drive - st<strong>an</strong>dard or oversized motors (Direct for 3-5 ton only)• We don’t prepackage options• Choose options tailored to suit each job —pay only for what is needed• Units ship with options installed —<strong>an</strong>d within our st<strong>an</strong>dard ship cycle timeFactory Installed Options• Through-the-Base — Electrical• Convenience Outlet — Powered or unpowered• Unit Disconnect Switch• Smoke Detectors — Supply, return, or both• Condenser Coil Coating• Hinged Access Service P<strong>an</strong>els• Discharge Air Sensor• F<strong>an</strong> Fail <strong>an</strong>d Clogged Filter Switches• Condenser Coil Guard — Hail Protection Quality• TCI (<strong>Tr<strong>an</strong>e</strong> Communication Interface)• LonTalk (Communication Interface)• 2" Pleated Media filters• Phase MonitorThe same <strong>Tr<strong>an</strong>e</strong> Quality <strong>an</strong>dReliability … with added Flexibility!Effective 1/1/06PH-24For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Precedent Packaged Heat PumpConvertible 3-10 TonsTable PH-25-A — Base Unit — St<strong>an</strong>dard Efficiency — ReliaTel Microprocessor ControlsCooling Cabinet ShippingUnit Perform<strong>an</strong>ce2 Capacity Dimensions (in.) Downflow Downflow Weight Max1Tons Ordering No.3 SEER/EER (Btuh) H x W x L Supply Return (Ibs.) MCA* Fuse*WSC – 208-230/1/60 – Single Phase – No Heat3 WSC036E1R0A0000 13.0 37,650 32 x 44 x 70 18 x 15.5 24 x 14 589 31.2 454 WSC048E1R0A0000 13.0 49,040 32 x 44 x 70 18 x 15.5 24 x 14 600 38.9 605 WSC060E1R0A0000 13.0 58,360 41 x 53 x 89 33 x 17.5 32.13 x 17.5 825 44.6 70WSC – 208-230/3/60 – Three Phase – No Heat3 WSC036A3R0A0000 10.2 38,100 32 x 44 x 70 18 x 15.5 24 x 14 534 19.1 304 WSC048A3R0A0000 10.7 50,800 32 x 44 x 70 18 x 15.5 24 x 14 566 24.4 355 WSC060A3R0A0000 10.1 62,100 32 x 44 x 70 18 x 15.5 24 x 14 584 32.6 503 WSC036E3R0A0000 13.0 38,030 32 x 44 x 70 18 x 15.5 24 x 14 589 23.8 354 WSC048E3R0A0000 13.0 50,130 32 x 44 x 70 18 x 15.5 24 x 14 600 27.5 405 WSC060E3R0A0000 13.0 63,440 41 x 53 x 89 33 x 17.5 32.13 x 17.5 825 30.2 456 WSC072A3R0A0000 10.6 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 32.2 507 1 /2 WSC090A3R0A0000 10.1 92,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 937 41.4 6010 WSC120A3R0A0000 10.1 119,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1084 50.4 60WSC – 460/3/60 – Three Phase – No Heat3 WSC036A4R0A0000 10.2 38,100 32 x 44 x 70 18 x 15.5 24 x 14 534 9.9 154 WSC048A4R0A0000 10.7 50,800 32 x 44 x 70 18 x 15.5 24 x 14 566 12.1 155 WSC060A4R0A0000 10.1 62,100 32 x 44 x 70 18 x 15.5 24 x 14 584 16.6 253 WSC036E4R0A0000 13.0 38,030 32 x 44 x 70 18 x 15.5 24 x 14 589 11.4 154 WSC048E4R0A0000 13.0 50,130 32 x 44 x 70 18 x 15.5 24 x 14 600 12.3 155 WSC060E4R0A0000 13.0 63,440 41 x 53 x 89 33 x 17.5 32.13 x 17.5 825 14.7 206 WSC072A4R0A0000 10.6 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 16.6 257 1 /2 WSC090A4R0A0000 10.1 92,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 937 21.9 3510 WSC120A4R0A0000 10.1 119,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1084 26.4 35WSC – 575/3/60 – Three Phase – No Heat3 WSC036AWR0A0000 10.2 38,100 32 x 44 x 70 18 x 15.5 24 x 14 534 8.3 154 WSC048AWR0A0000 10.7 50,800 32 x 44 x 70 18 x 15.5 24 x 14 566 10.1 155 WSC060AWR0A0000 10.1 62,100 32 x 44 x 70 18 x 15.5 24 x 14 584 13.1 203 WSC036EWR0A0000 13.0 38,030 32 x 44 x 70 18 x 15.5 24 x 14 589 8.8 154 WSC048EWR0A0000 13.0 50,130 32 x 44 x 70 18 x 15.5 24 x 14 600 9.5 155 WSC060EWR0A0000 13.0 63,440 41 x 53 x 89 33 x 17.5 32.13 x 17.5 825 11.0 156 WSC072AWR0A0000 10.6 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 12.5 157 1 /2 WSC090AWR0A0000 10.1 92,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 937 16.8 2510 WSC120AWR0A0000 10.1 119,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1084 21.0 25* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.1 HCAR breaker per NEC.2 SEER applies, 3-5 tons; EER applies 6-10 tons.3 Digit 7 - A=R-22, E=410A.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PH-25 Effective 1/1/06


Digit Description Order Number1-8 Main Assembly (see previous page)9 Unit ControlsUnit Controls -ReliaTel Micro-processor .................. R10 (See Heater Table below)11 Minor Design SequenceFirst Sequence ........................................................ A12-13 Service SequenceFirst Sequence (Factory Assiged) ............................ ✱,✱14 Fresh Air SelectionNo Fresh Air ............................................................. 00-50% M<strong>an</strong>ual Outside Air Damper9 ......................... A0-50% Motorized Outside Air Damper ........................ B0-100% Economizer, Dry Bulb withoutBarometric Relief 1 ............................................... C0-100% Economizer, Dry Bulb withBarometric Relief1 ............................................... D0-100% Economizer, Reference Enthalpywithout Barometric Relief1 ..................................... E0-100%Economizer, Reference Enthalpywith Barometric Relief1 ......................................... F0-100%Economizer, Comparative Enthalpywithout Barometric Relief 1 ................................... G0-100%Economizer, Comparative Enthalpywith Barometric Relief 1 ......................................... H15 Supply F<strong>an</strong>/Drive Type/MotorSt<strong>an</strong>dard Drive ......................................................... 0Oversized Motor ....................................................... 1Optional Belt Drive Motor (3 phase only) .................... 216 Hinged Service Access & FiltersSt<strong>an</strong>dard P<strong>an</strong>els & Filters ......................................... 0Hinged Access P<strong>an</strong>els & St<strong>an</strong>dard Filters .................. ASt<strong>an</strong>dard P<strong>an</strong>els & 2" Pleated Filters ......................... BHinged Access P<strong>an</strong>els & 2" Pleated Filters ................ C17 Condenser Coil ProtectionSt<strong>an</strong>dard Coil ........................................................... 0St<strong>an</strong>dard Coil with Hail Guard ................................... 1Epoxy Coated Condenser Coil .................................. 2Epoxy Coated Condenser Coil with Hail Guard .......... 318 Through the Base ProvisionsNo Through the Base Provisions ............................... 0Through the Base Electric8 ...................................... A1 Economizer with Barometric Relief is for downfllow configured units only. Order Economizer withoutBarometric Relief for horizontal configuration. Barometric relief for horizontal configured units mustbe ordered as field installed accessory BAYBARM010A.2 Requires use of Disconnect or Circuit Breaker.3 St<strong>an</strong>dard refrigeration metering device - short orifice.4 Frostat c<strong>an</strong>not be field installed in electro-mech<strong>an</strong>ical units.5 High Pressure control is st<strong>an</strong>dard on 3 phase units with scroll compressor <strong>an</strong>d WSC036A.6 Not available with BAYFRST001A High Temperature Stat accessory.7 The return air smoke detector may not fit up or work properly on the Convertible units when used inHeaters (Digit 10)kW Nominal No.Rating Digit BTUH Stages Used With208/240/1/603.8/5.0 (A) 12,800/17,100 1 WSC036-060A17.5/10.0 (D) 25,600/34,100 2 WSC036-060A110.4/13.8 (F) 35,300/47,100 2 WSC036-060A113.2/17.6 (G) 45,100/60,100 2 WSC048-060A1208/240/3/604.5/6.0 (B) 13,400/20,500 1 WSC036-060A39.0/12.0 (E) 30,800/59,400 2 WSC036-060A313.1/17.4 (G) 44,600/59,400 2 WSC036-060A317.3/23.0 (J) 58,900/78,500 2 WSC060A36.75/9.0 (C) 23,000/30,700 1 W*C072-090A313.5/18.0 (G) 46,100/61,400 1 W*C072-120A320.3/27.0 (K) 69,000/92,100 2 W*C072-120A327.0/36.0 (N) 92,200/122,900 2 W*C072-120A340.5/54.0 (P) 138,200/184,300 2 W*C120A3Effective 1/1/06Precedent Packaged Heat PumpConvertible 3-10 Tons(Model Digit Numbers)PH-26Digit Description Order Number19 Disconnect/Circuit Breaker/Phase Monitor (3 phase only)No Disconnect /Circuit Breaker/No Phase Monitor ...... 0Non-Fused Disconnect8 ........................................... 1Circuit Breaker8 ....................................................... 2Phase Monitor0 ....................................................... 3Phase Monitor0 & Non-Fused Disconnect Switch ...... 4Phase Monitor0 & Circuit Breaker ............................. 520 Convenience OutletNo Convenience Outlet ............................................. 0Unpowered Convenience Outlet ............................... APowered Convenience Outlet (3 phase only)2 ............ B21 Communications OptionsNo Communications Interface ................................... 0<strong>Tr<strong>an</strong>e</strong> Communications Interface ............................... 1LonTalk ® Communications Interface .......................... 222 Refrigeration System OptionSt<strong>an</strong>dard Refrigeration System ................................. 023 Refrigeration ControlsNo Refrigeration Control ........................................... 0High Pressure Control5 ............................................ 1Frostat4 ................................................................... 2Cr<strong>an</strong>kcase Heater .................................................... 3High Pressure Control5 <strong>an</strong>d Frostat4 ........................ 4High Pressure Control5 <strong>an</strong>d Cr<strong>an</strong>kcase Heater .......... 5Frostat4 <strong>an</strong>d Cr<strong>an</strong>kcase Heater5 ............................. 6High Pressure Control5, Frostat4 <strong>an</strong>dCr<strong>an</strong>kcase Heater5 .............................................. 724 Smoke Detector67No Smoke Detector .................................................. 0Return Air Smoke Detector ....................................... ASupply Air Smoke Detector ....................................... BSupply <strong>an</strong>d Return Air Smoke Detectors .................... C25 Monitoring ControlsNo Monitoring Control ............................................... 0Clogged Filter Switch ................................................ 1F<strong>an</strong> Failure Switch .................................................... 2Discharge Air Sensing Tube ...................................... 3Clogged Filter Switch <strong>an</strong>d F<strong>an</strong> Fail Switch .................. 4Clogged Filter Switch <strong>an</strong>d DischargeAir Sensing Tube .................................................... 5F<strong>an</strong> Fail Switch <strong>an</strong>d Discharge Air Sensing Tube ......... 6Clogged Filter <strong>an</strong>d F<strong>an</strong> Fail Switches<strong>an</strong>d Discharge Air Sensing Tube ............................. 7conjunction with 3rd party accessories such as bolt on heat wheels, economizers <strong>an</strong>d powerexhaust. Do not order the return air smoke detectors when using this type of accessory.8 Through the base electric required when ordering disconnect/circuit breaker options.9 The m<strong>an</strong>ual outside air damper will ship factory supplied within the unit, but must be fieldinstalled.0 Phase Monitor is st<strong>an</strong>dard on T/Y/WSC060A3,4,W models. All other models Phase Monitor willbe <strong>an</strong> option.kW Nominal No.Rating Digit BTUH Stages Used With460/3/606.0 (B) 20,500 1 WSC036-060A412.0 (E) 41,000 2 WSC036-060A417.4 (G) 59,400 2 WSC036-060A423.0 (J) 78,500 2 WSC060A49.0 (C) 30,700 1 W*C072-090A418.0 (G) 61,400 1 W*C072-120A427.0 (K) 92,100 2 W*C072-120A436.0 (N) 122,900 2 W*C072-120A454.0 (P) 184,300 2 W*C120A4575/3/606.0 (B) 20,500 1 WSC036-060AW12.0 (E) 41,000 2 WSC036-060AW17.4 (G) 59,400 2 WSC036-060AW23.0 (J) 78,500 2 WSC060AW9.0 (C) 30,700 1 W*C072-090AW18.0 (G) 61,400 1 W*C072-120AW27.0 (K) 92,100 2 W*C072-120AW36.0 (N) 122,900 2 W*C072-120AW54.0 (P) 184,300 2 W*C120AWFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Precedent Packaged Heat PumpConvertible 3-10 TonsTable PH-27-A — Accessory Electric Heaters – Unit with heater is single circuit / single point power entryModel Power kW Nominal No.Number Supply Rating BTUH Stages Used With1BAYHTRR105A 208/240/1/60 3.8/5.0 12,800/17,100 1 WSC036-060(A or E)1BAYHTRR110A 208/240/1/60 7.5/10.0 25,600/34,100 2 WS036-060(A or E)1BAYHTRR114A 208/240/1/60 10.4/13.8 35,300/47,100 2 WSC036-060(A or E)1BAYHTRR118A 208/240/1/60 13.2/17.6 45,100/60,100 2 WSC048-060(A or E)1BAYHTRR306A 208/240/3/60 4.5/6.0 13,400/20,500 1 WSC036-060(A or E)3BAYHTRR312A 208/240/3/60 9.0/12.0 30,800/41,000 2 WSC036-060(A or E)3BAYHTRR318A 208/240/3/60 13.1/17.4 44,600/59,400 2 WSC036-060(A or E)3BAYHTRR323A 208/240/3/60 17.3/23.0 58,900/78,500 2 WSC060(A or E)3BAYHTRS309A 208/240/3/60 6.75/9.0 23,000/30,700 1 WSC072-090A3BAYHTRS318A 208/240/3/60 13.5/18.0 46,100/61,400 1 WSC072-090A3BAYHTRS327A 208/240/3/60 20.3/27.0 69,000/92,100 2 WSC072-090A3BAYHTRS336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WSC072-090A3BAYHTRT318A 208/240/3/60 13.5/18.0 46,100/61,400 1 WSC120A3BAYHTRT327A 208/240/3/60 20.3/27.0 69,000/92,100 2 WSC120A3BAYHTRT336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WSC120A3BAYHTRT354A 208/240/3/60 40.5/54.0 138,200/184,300 2 WSC120A3BAYHTRS409A 460/3/60 9.0 30,700 1 WSC072-090A4BAYHTRS418A 460/3/60 18.0 61,400 1 WSC072-090A4BAYHTRS427A 460/3/60 27.0 92,100 2 WSC072-090A4BAYHTRS436A 460/3/60 36.0 122,900 2 WSC072-090A4BAYHTRT418A 460/3/60 18.0 61,400 1 WSC120A4BAYHTRT427A 460/3/60 27.0 92,100 2 WSC120A4BAYHTRT436A 460/3/60 36.0 122,900 2 WSC120A4BAYHTRT454A 460/3/60 54.0 184,300 2 WSC120A4BAYHTRR406A 460/3/60 6.0 20,500 1 WSC036-060(A or E)4BAYHTRR412A 460/3/60 12.0 41,000 2 WSC036-060(A or E)4BAYHTRR418A 460/3/60 17.4 59,400 2 WSC036-060(A or E)4BAYHTRR423A 460/3/60 23.0 78,500 2 WSC060(A or E)4BAYHTRSW09A 575/3/60 9.0 30,700 1 WSC072-090AWBAYHTRSW18A 575/3/60 18.0 61,400 1 WSC072-090AWBAYHTRTW18A 575/3/60 18.0 61,400 1 WSC120AWBAYHTRSW27A 575/3/60 27.0 92,100 2 WSC072-090AWBAYHTRTW27A 575/3/60 27.0 92,100 2 WSC120AWBAYHTRSW36A 575/3/60 36.0 122,900 2 WSC072-090AWBAYHTRTW36A 575/3/60 36.0 122,900 2 WSC120AWBAYHTRTW54A 575/3/60 54.0 184,300 2 WSC120AWBAYHTRRW06A 575/3/60 6.0 20,500 1 WSC036-060(A or E)WBAYHTRRW12A 575/3/60 12.0 41,000 2 WSC036-060(A or E)WBAYHTRRW18A 575/3/60 17.4 59,400 2 WSC036-060(A or E)WBAYHTRRW23A 575/3/60 23.0 78,500 2 WSC060(A or E)W1 A = R-22, E = 410ATable PH-27-B — Zone Sensors for ReliaTel Controlled UnitsModelNumber Description Used With3BAYMTPL003B Retrofit Wall Cover Plate Kit 7.25" x 6.0" BAYSENS019CBAYMTPL004B Retrofit Wall Cover Plate Kit 4.75" x 4.75" BAYSENS007B,009B,011B,013,014C,017BBAYSENS007B Single Setpoint M<strong>an</strong>ual Ch<strong>an</strong>geover WSC036-060(A or E)-120ABAYSENS009B Dual Setpoint M<strong>an</strong>ual or Auto Ch<strong>an</strong>geover WSC036-060(A or E)-120ABAYSENS011B Dual Setpoint M<strong>an</strong>. or Auto Ch<strong>an</strong>ge-over with SystemFunction LightsWSC036-060(A or E)-120ABAYSENS013C1 Room Sensor w/ Override <strong>an</strong>d C<strong>an</strong>cel Buttons WSC036-060(A or E)-120ABAYSENS014C1 Room Sensor w/ Temp. Adjustment with Override <strong>an</strong>dC<strong>an</strong>cel ButtonsWSC036-060(A or E)-120ABAYSENS017B Remote Room Sensor 010B, & 019C BAYSENS007B,009B,011B,019CBAYSENS019C Programmable Night Setback w/System Function Lights WSC036-060(A or E)-120ABAYSENS031A2 Digital Display Zone Sensor WSC036-060(A or E)-120ABAYSENS032A2 Dual Thermistor Remote Zone Sensor WSC036-060(A or E)-120A1 Used with Integrated Comfort TM Systems, <strong>an</strong>y unit type. These sensors do not work with TCM. Consult BASD Marketing for them.2 Functional only with ReliaTel controls.3 A=R-22, E=410AFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleasePH-27 Effective 1/1/06refer to Product Data <strong>an</strong>d/or Installers Guides.


Precedent Packaged Heat PumpConvertible 3-10 TonsTable PH-28-A — AccessoriesModel Number Description Used WithrBAYABRD001C ........................... ReliaTel Options Module ..................................................... See Note6BAYBARM010A3 ....................... Barometric Relief .................................................................... WSC036-060(A or E)BAYBARM011A3 ....................... Barometric Relief .................................................................... WSC072-120ABAYCCHT010B ........................... Cr<strong>an</strong>kcase Heater .................................................................. WSC036-060(A or E), WSC072-120A1, A3BAYCCHT011B ........................... Cr<strong>an</strong>kcase Heater .................................................................. WSC036-060(A or E), WSC072-120A1, A4, AWBAYCCHT012A ........................... Cr<strong>an</strong>kcase Heater .................................................................. WSC090A3BAYCCHT013A ........................... Cr<strong>an</strong>kcase Heater .................................................................. WSC090A4BAYCCHT014A ........................... Cr<strong>an</strong>kcase Heater .................................................................. WSC090AWBAYCO2K001Bw ........................ CO 2 Sensor Kit, Wall Mounted ............................................... WSC036-060(A or E), WSC072-120A w/EconomizerBAYCO2K003Bw ........................ CO 2 Sensor Kit, Duct Mounted .............................................. WSC036-060(A or E), WSC072-120A w/EconomizerBAYCURB042A4 ....................... Roof Curb ............................................................................... WSC036-060(A or E)BAYCURB043A4 ....................... Roof Curb ............................................................................... WSC072-120ABAYDFPS003A6 ........................ Clogged Filter Switch ............................................................. WSC036-060(A or E)-120ABAYDFPS004A6 ........................ F<strong>an</strong> Failure Switch .................................................................. WSC036-060(A or E)-120ABAYDMPR051A .......................... 0-50% Motorized Outside Air Damper .................................... WSC036-060(A or E)BAYDMPR053Be ....................... 0-50% M<strong>an</strong>ual Outside Air Damper ........................................ WSC036-060(A or E)BAYDMPR054A .......................... 0-50% Motorized Outside Air Damper .................................... WSC072-120ABAYDMPR056Be ....................... 0-50% M<strong>an</strong>ual Outside Air Damper ........................................ WSC072-120ABAYECON085A ........................... 0-100% Economizer without Barometric Relief ....................... WSC036-060(A or E)BAYECON087A ........................... 0-100% Economizer without Barometric Relief ....................... WSC072-120ABAYENTH005A1 ........................ Reference Enthalpy Kit ........................................................... BAYECON085A,087ABAYENTH006B1 ........................ Comparative Enthalpy Kit ....................................................... BAYECON085A,087ABAYFRST001A7 ........................ High Temperature Stat ............................................................ WSC036-060(A or E), WSC072-120ABAYGARD036B ........................... Condenser Coil Hail Guard ..................................................... WSC036-060(A or E)BAYGARD040B ........................... Condenser Coil Hail Guard ..................................................... WSC072-090ABAYGARD041B ........................... Condenser Coil Hail Guard ..................................................... WSC120ABAYHSDR012A ........................... High Static Drive Kit ............................................................... WSC072ABAYHSMT073A ........................... .45 HP Direct Drive Oversized Motor Kit ................................. WSC036(A or E)1,(A or E)3BAYHSMT074A ........................... .45 HP Direct Drive Oversized Motor Kit ................................. WSC036(A or E)4BAYHSMT075A ........................... .45 HP Direct Drive Oversized Motor Kit ................................. WSC036(A or E)WBAYHSMT076A ........................... .75 HP Direct Drive Oversized Motor Kit ................................. WSC048(A or E)1,(A or E)3BAYHSMT077A ........................... .75 HP Direct Drive Oversized Motor Kit ................................. WSC048(A or E)4BAYHSMT078A ........................... .75 HP Direct Drive Oversized Motor Kit ................................. WSC048(A or E)WBAYHSMT079A ........................... 1.2 HP Direct Drive Oversized Motor Kit ................................. WSC060(A or E)1,(A or E)3BAYHSMT080A ........................... 1.2 HP Direct Drive Oversized Motor Kit ................................. WSC060(A or E)4BAYHSMT081A ........................... 1.2 HP Direct Drive Oversized Motor Kit ................................. WSC060(A or E)WBAYHSMT082A ........................... 2 HP Belt Drive Oversized Motor ............................................ WSC072A3, A4BAYHSMT083A ........................... 2 HP Belt Drive Oversized Motor ............................................ WSC072AWBAYHSMT086A ........................... 3 HP Belt Drive Oversized Motor ............................................ WSC090A3, A4BAYHSMT087A ........................... 3 HP Belt Drive Oversized Motor ............................................ WSC090AWBAYHSMT090A ........................... 5 HP Belt Drive Oversized Motor ............................................ WSC120A3, A4BAYHSMT091A ........................... 5 HP Belt Drive Oversized Motor ............................................ WSC120AWBAYICSI003A8 ........................... <strong>Tr<strong>an</strong>e</strong> Communications Interface ............................................ WSC036-060(A or E), WSC072-120ABAYKSKT255A ............................ Quick Start Kit ........................................................................ WSC048,060(A or E)A1BAYKSKT256A ............................ Quick Start Kit ........................................................................ WSC036(A or E)1BAYLOAM020B6 ....................... Evaporator Defrost Control (Frostat) ....................................... WSC036-060(A or E), WSC072-120ABAYLTCI002B0 .......................... LonTalk® Communications Interface ...................................... WSC036-060(A or E), WSC072-120ABAYPWRX026A9 ....................... Power Exhaust ....................................................................... WSC072-120A3BAYPWRX027A9 ....................... Power Exhaust ....................................................................... WSC072-120A4BAYPWRX028A9 ....................... Power Exhaust ....................................................................... WSC072-120AWBAYQACB009A45 .................... Quick Adapt Roof Curb ........................................................... WSC036-060(A or E)BAYQACB010A45 .................... Quick Adapt Roof Curb ........................................................... WSC036-060(A or E)BAYQACB011A4q .................... Quick Adapt Roof Curb ........................................................... WSC036-060(A or E), WSC072-120ABAYQACB012A4q .................... Quick Adapt Roof Curb ........................................................... WSC036-060(A or E), WSC072-120ABAYSENS016A ........................... Temperature Sensor ............................................................... WSC036-060(A or E)BAYSERV001A ........................... Selective Resist<strong>an</strong>ce Service Tester ....................................... WSC036-060(A or E), WSC072-120ABAYSTAT023 ............................... Remote Potentiometer ............................................................ BAYECON085A,087ABAYTUBE005A26 ..................... Discharge Air Sensing Kit ....................................................... WSC036-060(A or E)BAYTUBE007 .............................. Discharge Air Sensing Kit ....................................................... WSC072-120ABAYVNOR001Bw6 .................... Ventilation Override Kit w/ReliaTel options module .............. WSC036-060(A or E), WSC072-120A1 Kits contain all necessary parts to achieve desired level of enthalpy control.2 Used for true discharge air sensing in both heating <strong>an</strong>d cooling. Required for supply air tempering.3 Barometric Relief accessory installs in ductwork for horizontal configuration. For downflow configuration, installs in the unit's horizontal return duct. See Installer's Guide for completeinstructions.4 Lynn Haven m<strong>an</strong>ufacturing has a no return policy for this roof curb.5 BAYQACB009A adapts Voyager BAYCURB021A roof curb to accept Precedent 3-5 ton unit. BAYQACB010A adapts Voyager (BAYCURB022A roof curb to accept Precedent 3-5 ton unit.6 BAYABRD001C is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS003A), F<strong>an</strong> Fail Switch (BAYDFPS004A), Discharge Air Sensing Kit BAYTUBE004Aor BAYTUBE005A) or Evaporator Defrost Control (Frostat) (BAYLOAM020B) Ventilation Override Kit (BAYVNOR001B) unless the following options are factory installed: Frostat, SmokeDetector, Clogged Filter Switch, F<strong>an</strong> Failure Switch, Discharge Air Sensing Kit. These factory installed options Include the ReliaTel Options Module.7 C<strong>an</strong>not be used in conjunction with factory installed smoke detector.8 Interface allows unit to communicate with Tracer 100, Tracker, VariTrac II, <strong>an</strong>d is the preferred method of communication to Tracer Summit.9 Power Exhaust c<strong>an</strong>not be used with Barometric Relief. Order Economizer without Barometric Relief.0 Interface allows unit to communicate as a <strong>Tr<strong>an</strong>e</strong> LonTalk device or directly with generic LonTalk Network BAS Controls.q BAYQACB012A adapts Voyager BAYCURB025 roof curb to accept Convertible 6-10 ton unit.BAYQACB011A adapts Voyager BAYCURB022B roof curb to accept Precedent 6-10 ton unit.w Field installed accessory. Requires <strong>an</strong> economizer.e The m<strong>an</strong>ual outside air damper will ship factory supplied within the unit, but must be field installed.r A=R-22, E=410A.Effective 1/1/06PH-28For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Light Commercial Packaged HeatPump New Model Quick ReferenceTable PH-29-A — Quick ReferencePrecedentPrecedentVoyager Horizontal Voyager Downflow Controls Ordering Number Service Model NumberWCH036B100A WCD036C100B Microprocessor WSC036*1R0A0000 WSC036*1R0A**000000000000WCH036B300A WCD036C300B Microprocessor WSC036*3R0A0000 WSC036*3R0A**000000000000WCH036B400A WCD036C400B Microprocessor WSC036*4R0A0000 WSC036*4R0A**000000000000WCH048C100B WCD048C100B Microprocessor WSC048*1R0A0000 WSC048*1R0A**000000000000WCH048C300B WCD048C300B Microprocessor WSC048*3R0A0000 WSC048*3R0A**000000000000WCH048C400B WCD048C400B Microprocessor WSC048*4R0A0000 WSC048*4R0A**000000000000WCH048CW00B WCD048CW00B Microprocessor WSC048*WR0A0000 WSC048*WR0A**000000000000WCH060C100B WCD060C100B Microprocessor WSC060*1R0A0000 WSC060*1R0A**000000000000WCH060C300B WCD060C300B Microprocessor WSC060*3R0A0000 WSC060*3R0A**000000000000WCH060C400B WCD060C400B Microprocessor WSC060*4R0A0000 WSC060*4R0A**000000000000WCH060CW00B WCD060CW00B Microprocessor WSC060*WR0A0000 WSC060*WR0A**000000000000WCH075C300B WCD075C300B Microprocessor WSC072A3R0A0000 WSC072A3R0A**000000000000WCH075C400B WCD075C400B Microprocessor WSC072A4R0A0000 WSC072A4R0A**000000000000WCH075CW00B WCD075CW00B Microprocessor WSC072AWR0A0000 WSC072AWR0A**000000000000WCH090C300B WCD090C300B Microprocessor WSC090A3R0A0000 WSC090A3R0A**000000000000WCH090C400B WCD090C400B Microprocessor WSC090A4R0A0000 WSC090A4R0A**000000000000WCH090CW00B WCD090CW00B Microprocessor WSC090AWR0A0000 WSC090AWR0A**000000000000WCH120B300E WCD120B300E Microprocessor WSC120A3R0A0000 WSC120A3R0A**000000000000WCH120B400E WCD120B400E Microprocessor WSC120A4R0A0000 WSC120A4R0A**000000000000WCH120BW00E WCD120BW00E Microprocessor WSC120AWR0A0000 WSC120AWR0A**000000000000* Digit 7- A=R-22, E=410A.For additional Controls Information:See ReliaTel <strong>an</strong>d Micro Control features on PC-35 <strong>an</strong>d PC-36.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PH-29 Effective 1/1/06


Voyager PackagedHeat Pump with ReliaTelControls 12½ through 20 Tons12½ – 20 TonWCD/WCH—Downflow/Horizontal• EER up to 10.0• ReliaTel processor control features arelisted on page PC-35• Built-in <strong>an</strong>ti-short cycle, time-delay relay<strong>an</strong>d minimum on time controls• 2" filters for 12½ - 20 ton units• Liquid line drier• Built-in fork lift holes• Operating charge of R-22• “Quick-Sess” service p<strong>an</strong>els slide in<strong>an</strong>d out• Scroll compressors• Dedicated horizontal <strong>an</strong>d downflow designs• Single-side access• Single point power for electric heat• Complete line of optional electric heaters• Internally enh<strong>an</strong>ced coil tubing• Low ambient to 0°F st<strong>an</strong>dard• Colored <strong>an</strong>d numbered wiring• Common cabinet <strong>an</strong>d accessories asTCD/TCH <strong>an</strong>d YCD/YCH models• Quick-adjust idler arm pulley.• 5-year limited compressor warr<strong>an</strong>ty(12½ – 15 tons)• 1-year limited parts warr<strong>an</strong>ty• 1-year limited compressor warr<strong>an</strong>ty (20tons)Table PH-30-A — WCD Downflow or WCH Horizontal — Micro Control UnitUnit Power Supply Perform<strong>an</strong>ce Cooling Dimensions (in.) Shipping Max Fuse Size or5 DownflowTons Model No. Volts/Phase/Hz EER (1Ø) Capacity (Btuh) H x W x L Weight (Ibs.) MCA3 Max Circuit Breaker Roofcurb12 1 /2 WCD150B300G 208-230/3/60 9.50 152,000 50 1 /8 x 71 5 /16 x 107 5 /16 1719 66 80 BAYCURB026B15 WCD180B300H 208-230/3/60 9.60 180,000 50 1 /8 x 71 5 /16 x 107 5 /16 1857 76 90 BAYCURB026B20 WCD240B300G 208-230/3/60 10.0 244,00 54 x 85 5 /16 x 122 5 /16 2467 96 125 BAYCURB027B12 1 /2 WCD150B400G 460/3/60 9.50 152,000 50 1 /8 x 71 5 /16 x 107 5 /16 1719 31 40 BAYCURB026B15 WCD180B400H 460/3/60 9.60 180,000 50 1 /8 x 71 5 /16 x 107 5 /16 1857 39 45 BAYCURB026B20 WCD240B400G 460/3/60 10.0 244,000 54 x 85 5 /16 x 122 5 /16 2467 49 60 BAYCURB027B12 1 /2 WCD150BW00G 575/3/60 9.50 152,000 50 1 /8 x 71 5 /16 x 107 5 /16 1719 25 30 BAYCURB026B15 WCD180BW00H 575/3/60 9.60 180,000 50 1 /8 x 71 5 /16 x 107 5 /16 1857 31 35 BAYCURB026B20 WCD240BW00G 575/3/60 10.0 244,000 54 x 85 5 /16 x 122 5 /16 2467 38 45 BAYCURB027B12 1 /2 WCH150B300G 208-230/3/60 9.50 152,000 50 1 /8 x 71 5 /16 x 107 5 /16 1719 66 80 BAYCURB026B15 WCH180B300H 208-230/3/60 9.60 180,000 50 1 /8 x 71 5 /16 x 107 5 /16 1857 76 90 BAYCURB026B20 WCH240B300G 208-230/3/60 10.0 244,000 54 x 85 5 /16 x 122 5 /16 2467 96 125 BAYCURB027B12 1 /2 WCH150B400G 460/3/60 9.50 152,000 50 1 /8 x 71 5 /16 x 107 5 /16 1719 31 40 BAYCURB026B15 WCH180B400H 460/3/60 9.60 180,000 50 1 /8 x 71 5 /16 x 107 5 /16 1857 39 45 BAYCURB026B20 WCH240B400G 460/3/60 10.0 244,000 54 x 85 5 /16 x 122 5 /16 2467 49 60 BAYCURB027B12 1 /2 WCH150BW00G 575/3/60 9.50 152,000 50 1 /8 x 71 5 /16 x 107 5 /16 1719 25 30 BAYCURB026B15 WCH180BW00H 575/3/60 9.60 180,000 50 1 /8 x 71 5 /16 x 107 5 /16 1857 31 35 BAYCURB026B20 WCH240BW00G 575/3/60 10.0 244,000 54 x 85 5 /16 x 122 5 /16 2467 38 45 BAYCURB027BTonsSupply Supply Return Return Curb Size Roof OpeningDownflow W x L12Horizontal H x W12Downflow W x L12Horizontal H x W12H x W x L24W x L1212 1 /2 – 15 28 9 /16 x 55 1 /2 42 1 /2 x 26 1 /2 20 7 /8 x 63 42 1 /2 x 24 9 /16 14 1 /16 x 66 15 /16 x 102 1 /4 62 1 /2 x 73 1 /220 28 9 /16 x 69 1 /2 46 7 /16 x 26 1 /2 22 1 /4 x 77 46 7 /16 x 27 9 /16 14 1 /16 x 80 15 /16 x 117 1 /8 76 1 /2 x 81Effective 1/1/06PH-30For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Voyager PackagedHeat Pump with ReliaTelControls 12½ through 20 TonsTable PC-31-A — Factory Installed Accessories12 For Complete list of all Factory Installed Options, please refer to the FIOPSsection of this book.Digit Description Order Number Used With1-8 Main Assembly (see previous page)9-10 Factory Installed OptionsNo Options 00 WC*150-240Downflow Economizer3 0A WCD150-240Oversized Motor 0B WC*150-240Downflow Economizer <strong>an</strong>d Oversized Motor3 0C WCD150-240<strong>Tr<strong>an</strong>e</strong> Communications Interface (TCI)4 0F WC*150-240Downflow Economizer TCI34 0G WCD150-24011-12 Minor Design <strong>an</strong>d Service Sequence **1 Price includes accessory <strong>an</strong>d factory installation.2 Four (4) week shipping approximately.3 Some field set up required.4 TCI is for use with non-VariTrac systems <strong>an</strong>d VariTrac systems.Table PH-31-B — Zone SensorsModel Number Description Used WithBAYSENS007B ............ Single Setpoint M<strong>an</strong>ual Ch<strong>an</strong>geover with Emergency Heat ........................... WC*150-240BAYSENS009B ............ Dual Setpoint M<strong>an</strong>ual or Automatic Ch<strong>an</strong>geover with Emergency Heat .......... WC*150-240BAYSENS011B ............ Dual Setpoint M<strong>an</strong>ual or Automatic Ch<strong>an</strong>geover with System ........................ WC*150-240Function Light <strong>an</strong>d Emergency HeatBAYSENS013C1 ........ Room Sensor with Override Button ............................................................. WC*150-240BAYSENS014C1 ........ Room Sensor with Temperature Adjustment ................................................ WC*150-240BAYSENS019C ............ Programmable Night Setback ..................................................................... WC*150-240BAYSENS017B ............ Remote Room Sensor ............................................................................... BAYSENS007B, 009B, 011B, 019CBAYSENS031Aq ......... Digital Display Zone Sensor ....................................................................... WC*150-240BAYSENS032Aq ......... Dual Thermistor Remote Zone Sensor ....................................................... WC*150-240BAYMTPL003B ............ Retrofit Wall Cover Plate Kit (7 1 /4" x 6") ......................................................... BAYSENS019CBAYMTPL004A .............. Retrofit Wall Cover Plate Kit (4 1 /4" x 4 1 /4") .......................................................... BAYSENS007B, 009B, 011B, 017B,013C, 014CFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PH-31 Effective 1/1/06


Voyager Packaged Heat Pump withReliaTel Controls 12½ through 20Tons AccessoriesTable PH-32-A — Field Installed Accessories For complete list of of All Factory Installed Options refer to FIOPS section of thisbook.Model Number Description Used WithBAYABRD002Bq ........... ReliaTel Options Module .......................................... WCH/D150-240BAYCO2K002Bw ........... CO 2 Sensor Wall Mounted ........................................... WC*150-240 w/EconomizerBAYCO2K004Bw ........... CO 2 Sensor Duct Mounted .......................................... WC*150-240 w/EconomizerBAYCURB026B89 ........ Downflow Only Roof Curb ............................................ WCD150B, 180BBAYCURB027B89 ........ Downflow Only Roof Curb ............................................ WCD240BBAYECON089Aq ........... Downflow Economizer with Barometric Relief ................ WCD150B, 180BBAYECON090Aq ........... Downflow Economizer with Barometric Relief ................ WCD240BBAYECON091A .............. Horizontal Economizer ................................................. WCH150B, 180BBAYECON092A .............. Horizontal Economizer ................................................. WCH240BBAYFRST003A .............. High Temperature Stat ................................................ WC*150-240 w/ICSBAYENTH007A .............. Reference Enthalpy Kit ................................................ All BAYECON089-92ABAYENTH008A .............. Comparative Enthalpy Kit ............................................ All BAYECON089-92ABAYDMPR029C ............. 0-25% M<strong>an</strong>ual Outside Air Damper ............................... WCD/WCH (12½-20 Tons)BAYDMPR0057A ............ 0-50% Motorized Outside Air Damper ........................... WCD/WCH150B, 180BBAYDMPR058A ............. 0-50% Motorized Outside Air Damper ........................... WCD/WCH240BBAYDFPS005A0q ......... Clogged Filter Switch ................................................... WCD/WCH (12½-20 Tons)BAYDFPS006A0q ......... F<strong>an</strong> Failure Switch ....................................................... Economizers/0-50% Motorized Air DampersBAYGARD043Bq ........... Tool-less Hail Guard .................................................... WC*150BBAYGARD044Bq ........... Tool-less Hail Guard .................................................... WC*180BBAYGARD045Aq ........... Tool-less Hail Guard .................................................... WC*240BBAYPWRX029A ............. Power Exhaust for 230 volt units ................................... BAYECON089,090 (WCD150B, 180B, 240B3)BAYPWRX030A ............. Power Exhaust for 460 volt units ................................... BAYECON089,090 (WCD150B, 180B, 240B4)BAYPWRX031A ............. Power Exhaust for ....................................................... WCD150,180,240BWBAYHSDR002B6 .......... High Static Drive .......................................................... WCD/WCH150BBAYHSMT039B6q ........ 5HP Oversized Motor Kit .............................................. WCD/WCH150B, 180BBAYHSMT040B6q ........ 5HP Oversized Motor Kit .............................................. WC*150, 180BWBAYHSMT042A .............. 7-1/2HP Oversized Motor Kit ........................................ WC*240BWBAYHSMT098A6q ........ 7-1/2HP Oversized Motor Kit ........................................ WC*240B3BAYHSMT099A6q ......... 7-1/2HP Oversized Motor Kit ........................................ WC*240B4BAYICSI004Ber ............ <strong>Tr<strong>an</strong>e</strong> Communications Interface, Comm 3/4 (TCI) ......... WC*150-300BAYLOAM023A0q ......... Evaporator Deforst Control (Frostat) .............................. WC*150-240BAYLTCI003Br .............. LonTalk ® Communications Inteface (LCI) ....................... WC*150-300BAYSERV001A .............. Selective Resist<strong>an</strong>ce Service Tester .............................. WCD/WCH (12½-20 Tons)BAYSTAT023 ................. Remote Potentiometer ................................................ All BAYECON089-92ABAYSENS016A .............. Temperature Sensor .................................................... WCD/WCH (12½-20 Tons)BAYTUBE008A70q ....... Discharge Air Sensing Kit ............................................. WCD150-240BAYTUBE009A70q ....... Discharge Air Sensing Kit ............................................. WCH150-240BAYVNOR002B0 ......... Ventilation Override Kit ............................................. WCH150-240 w/ReliaTel Options Module1 Dimensions are in inches.2 Interior Dimension.3 MCA = Minimum Circuit Ampacity.4 Measurement Includes Curb Fl<strong>an</strong>ge.5 HACR Type Circuit per NEC.6 High static drive <strong>an</strong>d oversized motors are mutually exclusive, Do not Combine.7 Used for true discharge air sensing in both heating <strong>an</strong>d cooling models.8 Clarksville M<strong>an</strong>ufacturing has a no-return policy for this roof curb.9 For downflow use only. C<strong>an</strong> not be adapted for horizontal units.0 BAYABRD002B is required when ordering field installed accessories BAYDFPS005A or 006A, BAYTUBE008A or 009A <strong>an</strong>d BAYLOAM023A or BAYVNOR002B.q Field or factory installed option.w Field installed accessory. Requires <strong>an</strong> economizer.e Interface allows a unit with ReliaTel Controls to communicate with Tracer 100, Tracker, VariTrac II, <strong>an</strong>d is the prefered method of communication to Tracer Summit.r With ReliaTel controlled units only.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.Effective 1/1/06PH-32For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Voyager PackagedHeat Pump with MicroControls 12½ through 20 TonsTable PH-33-A — Downflow/Horizontal Supplementary Heaters:Model Power kW Nominal No.Number Supply Rating BTUH Stages Used WithAYDHTRK418A 460/3/60 18.0 61,400 1 WCD150B4,180B4AYDHTRK436A 460/3/60 36.0 122,900 2 WCD150B4,180B4AYDHTRK454A 460/3/60 54.0 184,300 2 WCD150B4,180B4AYDHTRK318A 208/240/3/60 13.5/18.0 46,100/61,400 1 WCD150B3, 180B3AYDHTRK336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WCD150B3, 180B3AYDHTRK354A 208/240/3/60 40.5/54.0 138,200/184,300 2 WCD150B3, 180B3AYDHTRL336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WCD240B3AYDHTRL354A 208/240/3/60 40.5/54.0 138,200/184,300 2 WCD240B3AYDHTRK372A 208/240/3/60 54.0/72.0 184,300/245,700 2 WCD240B3AYDHTRL436A 460/3/60 36.0 122,900 2 WCD240B4AYDHTRL454A 460/3/60 54.0 184,300 2 WCD240B4AYDHTRK472A 460/3/60 72.0 245,700 2 WCD240B4AYHHTRN318A 208/240/3/60 13.5/18.0 46,100/61,400 1 WCH150B3, 180B3AYHHTRP336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WCH150B3, 180B3AYHHTRP354A 208/240/3/60 40.5/54.0 138,200/184,300 2 WCH150B3, 180B3AYHHTRP418A 460/3/60 18.0 61,400 1 WCH180B4,150B4AYHHTRP436A 460/3/60 36.0 122,900 2 WCH180B4,150B4AYHHTRP454A 460/3/60 54.0 184,300 2 WCH180B4,150B4AYHHTRN336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WCH240B3AYHHTRN354A 208/240/3/60 40.5/54.0 138,200/184,300 2 WCH240B3AYHHTRN372A 208/240/3/60 54.0/72.0 184,300/245,700 2 WCH240B3AYHHTRN436A 460/3/60 36.0 122,900 2 WCH240B4AYHHTRN454A 460/3/60 54.0 184,300 2 WCH240B4AYHHTRN472A 460/3/60 72.0 245,700 2 WCH240B4AYDHTRKW18A 575/3/60 18.0 61,400 1 WCD120BW,180BWAYDHTRKW36A 575/3/60 36.0 122,900 2 WCD120BW,180BWAYDHTRKW54A 575/3/60 54.0 184,300 2 WCD120BW,180BWAYDHTRLW36A 575/3/60 36.0 122,900 2 WCD240BWAYDHTRLW54A 575/3/60 54.0 184,300 2 WCD240BWAYDHTRKW72A 575/3/60 72.0 245,700 2 WCD240BWAYHHTRNW18A 575/3/60 18.0 61,400 1 WCH150BW,180BWAYHHTRPW36A 575/3/60 36.0 122,900 2 WCH150BW,180BWAYHHTRPW54A 575/3/60 54.0 184,300 2 WCH150BW,180BWAYHHTRNW36A 575/3/60 36.0 122,900 2 WCH240BWAYHHTRNW54A 575/3/60 54.0 184,300 2 WCH240BWAYHHTRNW72A 575/3/60 72.0 245,700 2 WCH240BWNote: Unit with heater is single circuit/single point.See ReliaTel <strong>an</strong>d Micro Control features on PC-35 <strong>an</strong>d PC-36.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PH-33 Effective 1/1/06


Package Gas/ElectricConvertible 2 through 5 Tons• Architecturally integrated louvers <strong>an</strong>dcorner guards deliver durable protection,extra safety, <strong>an</strong>d great looks.• Weather Beater Top contoured for greatappear<strong>an</strong>ce <strong>an</strong>d reinforced for strength.• Ultra quiet operation provides best-in-classperform<strong>an</strong>ce with barely noticeable soundlevels.• Appli<strong>an</strong>ce grade finish of durable powderpaint baked on both sides of the p<strong>an</strong>els.• Exclusive Climatuff® high efficiencycompressor with internal overload protection.• Aerospace ducted outdoor f<strong>an</strong> with a highefficiency motor for quiet <strong>an</strong>d reliableoperation.• Composite Vortica® blower provides betterairflow <strong>an</strong>d less sound while using lessenergy.• Spine Fin outdoor coil for long lastingperform<strong>an</strong>ce <strong>an</strong>d durability.• Right side electrical service for high <strong>an</strong>d lowvoltage lines.• Rugged steel basep<strong>an</strong> features deep drawnduct connections <strong>an</strong>d emergency drains.• Steeply sloped composite drainp<strong>an</strong> willempty fast <strong>an</strong>d never rust.• Ships in horizontal configuration <strong>an</strong>dconverts quickly for downflow.• Complete set of customized electricheaters designed for all models. Featuresa polarized plug for easy installation.• Optional filter rack kits fit inside the unit.Available for 1" or 2" media.• Non-bleed exp<strong>an</strong>sion valves on indoor<strong>an</strong>d outdoor coils.• Direct drive 2 <strong>an</strong>d 3 speed indoor blowermotors.• Pressure taps easily accessed <strong>an</strong>dprotected inside compressor compartment.• Easy access liquid line tap insidecompressor compartment.• St<strong>an</strong>dard operation to 55°F as m<strong>an</strong>ufactured.• Low ambient cooling to 0°F with kit.• UL approved <strong>an</strong>d listed.• 20 year heat exch<strong>an</strong>ger, 10 yearcompressor, 10 year outdoor coil, <strong>an</strong>d5 year other parts limited warr<strong>an</strong>ty.(<strong>Residential</strong> Use Only)• Optional extended warr<strong>an</strong>ty.Table PG-1-A — 2YCX- XL13c - Convertible Package Gas/Electric - R-22CabinetModel AFUE (%) Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H x W x L2YCX – 208/230/1/602YCX3024A1040A 25,500 13.35/11.65 80 470 13.3 20 70 36 x 51 x 432YCX3024A1064A 25,500 13.35/11.65 80 481 13.3 20 70 36 x 51 x 432YCX3030A1040A 29,400 13.20/11.30 80 470 16.3 25 70 36 x 51 x 432YCX3030A1064A 29,400 13.20/11.30 80 481 16.3 25 70 36 x 51 x 432YCX3030A1075A 29,400 13.20/11.30 80 481 16.3 25 70 36 x 51 x 432YCX3036A1063A 35,200 13.00/11.20 80 479 23.0 35 72 36 x 51 x 432YCX3036A1075A 35,200 13.00/11.20 80 479 23.0 35 72 36 x 51 x 432YCX3036A1096A 35,200 13.00/11.20 80 485 23.0 35 72 36 x 51 x 432YCX3042A1064A 41,500 13.15/11.30 80 599 24.5 40 73 38 x 61 x 462YCX3042A1075A 41,500 13.15/11.30 80 599 24.5 40 73 38 x 61 x 462YCX3042A1096A 41,500 13.15/11.30 80 607 24.5 40 73 38 x 61 x 462YCX3048A1075A 48,000 13.30/11.25 80 656 29.0 45 73 38 x 61 x 462YCX3048A1096A 48,000 13.30/11.25 80 663 29.0 45 73 38 x 61 x 462YCX3048A1120A 48,000 13.30/11.25 80 669 29.0 45 73 38 x 61 x 462YCX3060A1096A 59,500 13.55/11.60 80 678 40.4 60 75 42 x 61 x 462YCX3060A1120A 59,500 13.55/11.60 80 684 40.4 60 75 42 x 61 x 46For information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-1 Effective 1/1/06


Package Gas/ElectricConvertible 1½ through 5 Tons• Architecturally integrated louvers <strong>an</strong>dcorner guards deliver durable protection,extra safety, <strong>an</strong>d great looks.• Ultra quiet operation provides best-in-classperform<strong>an</strong>ce with barely noticeable soundlevels.Table PG-2-A — 4YCX - XL13c - Convertible Package Gas/Electric - R-410ACabinetModel AFUE (%) Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H x W x L4YCX – 208/230/1/604YCX3018A1040A 18,800 13.55/11.15 80 471 10.1 15 69 36 x 51 x 434YCX3036A1064A 36,400 13.15/11.05 80 488 23.6 35 71 36 x 51 x 434YCX3036A1075A 36,400 13.15/11.05 80 488 23.6 35 71 36 x 51 x 434YCX3036A1096A 36,400 13.15/11.05 80 493 23.6 35 71 36 x 51 x 434YCX3048A1075A 46,500 13.05/11.00 80 645 31.5 50 73 38 x 61 x 464YCX3048A1096A 46,500 13.05/11.00 80 653 31.5 50 73 38 x 61 x 464YCX3048A1120A 46,500 13.05/11.00 80 659 31.5 50 73 38 x 61 x 464YCX3060A1096A 60,000 13.40/10.95 80 678 43.3 60 75 40 x 61 x 464YCX3060A1120A 60,000 13.40/10.95 80 684 43.3 60 75 40 x 61 x 464YCX – 208/230/3/604YCX3036A3064A 36,400 13.15/11.05 80 488 18.5 30 71 36 x 51 x 434YCX3036A3075A 36,400 13.15/11.05 80 488 18.5 30 71 36 x 51 x 434YCX3036A3096A 36,400 13.15/11.05 80 493 18.5 30 71 36 x 51 x 434YCX3048A3075A 46,500 13.05/11.00 80 645 24.0 35 73 38 x 61 x 464YCX3048A3096A 46,500 13.05/11.00 80 653 24.0 35 73 38 x 61 x 464YCX3048A3120A 46,500 13.05/11.00 80 659 24.0 35 73 38 x 61 x 464YCX3060A3096A 60,000 13.40/10.95 80 678 31.5 50 75 40 x 61 x 464YCX3060A3120A 60,000 13.40/10.95 80 684 31.5 50 75 40 x 61 x 464YCX – 460/3/604YCX3036A4064A 36,400 13.15/11.05 80 448 8.7 15 71 36 x 51 x 434YCX3036A4075A 36,400 13.15/11.05 80 448 8.7 15 71 36 x 51 x 434YCX3036A4096A 36,400 13.15/11.05 80 493 8.7 15 71 36 x 51 x 434YCX3048A4075A 46,500 13.05/11.00 80 645 11.7 15 73 38 x 61 x 464YCX3048A4096A 46,500 13.05/11.00 80 653 11.7 15 73 38 x 61 x 464YCX3048A4120A 46,500 13.05/11.00 80 659 11.7 15 73 38 x 61 x 464YCX3060A4096A 60,000 13.40/10.95 80 678 19.3 25 75 40 x 61 x 464YCX3060A4120A 60,000 13.40/10.95 80 684 19.3 25 75 40 x 61 x 46Effective 1/1/06• Appli<strong>an</strong>ce grade finish of durable powderpaint baked on both sides of the p<strong>an</strong>els.• Exclusive Climatuff® high efficiencycompressor with internal overloadprotection.• Aerospace ducted outdoor f<strong>an</strong> with a highefficiency motor for quiet <strong>an</strong>d reliableoperation.• Composite Vortica® blower providesbetter airflow <strong>an</strong>d less sound while usingless energy.• Spine Fin outdoor coil for long lastingperform<strong>an</strong>ce <strong>an</strong>d durability.• Right side electrical service for high <strong>an</strong>dlow voltage lines.• Rugged steel basep<strong>an</strong> features deepdrawn duct connections <strong>an</strong>d emergencydrains.• Steeply sloped composite drainp<strong>an</strong> willempty fast <strong>an</strong>d never rust.• Ships in horizontal configuration <strong>an</strong>dconverts quickly for downflow.PG-2• Complete set of customized electricheaters designed for all models. Featuresa polarized plug for easy installation.• Optional filter rack kits fit inside the unit.Available for 1" or 2" media.• Non-bleed exp<strong>an</strong>sion valves on indoor<strong>an</strong>d outdoor coils.• Direct drive 2 <strong>an</strong>d 3 speed indoor blowermotors.• Pressure taps easily accessed <strong>an</strong>dprotected inside compressor compartment.• Easy access liquid line tap insidecompressor compartment.• St<strong>an</strong>dard operation to 55°F as m<strong>an</strong>ufactured.• Low ambient cooling to 0°F with kit.• UL approved <strong>an</strong>d listed.• 20 year heat exch<strong>an</strong>ger, 10 yearcompressor, 10 year outdoor coil, <strong>an</strong>d5 year other parts limited warr<strong>an</strong>ty.(<strong>Residential</strong> Use Only)• Optional extended warr<strong>an</strong>ty.For information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Gas/ElectricConvertible 1½ through 5 Tons2/4YCX3018A through 2/4YCX3036AFor information on Roof Curbs <strong>an</strong>dRoof Curb Adaptors, please refer tothe Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-3 Effective 1/1/06


Package Gas/ElectricConvertible 1½ through 5 Tons2/4YCX3018A through 2/4YCX3036AFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.Effective 1/1/06PG-4For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Gas/ElectricConvertible 1½ through 5 Tons2/4YCX3042A through 2/4YCX3060AFor information on Roof Curbs <strong>an</strong>dRoof Curb Adaptors, please refer tothe Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-5 Effective 1/1/06


Package Gas/ElectricConvertible 1½ through 5 Tons2/4YCX3042A through 2/4YCX3060AFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.Effective 1/1/06PG-6For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Gas/ElectricConvertible 2 through 5 Tons• All steel louvers <strong>an</strong>d cabinet for rugged,long lasting protection.• Stainless steel burners <strong>an</strong>d heat exch<strong>an</strong>gerfor extra long life <strong>an</strong>d safety.• Quiet operation delivers great in-homecomfort with minimal sound.• Weather Beater Top contoured for greatappear<strong>an</strong>ce <strong>an</strong>d reinforced for strength.• Appli<strong>an</strong>ce grade finish of durable powderpaint baked on both sides of the p<strong>an</strong>els.• Exclusive Climatuff® high efficiencycompressor with internal overloadprotection.• High efficiency outdoor f<strong>an</strong> motor for quiet<strong>an</strong>d reliable operation.• Composite Vortica® blower providesbetter airflow <strong>an</strong>d less sound while usingless energy.• Spine Fin outdoor coil for long lastingperform<strong>an</strong>ce <strong>an</strong>d durability.• Right side electrical service for high <strong>an</strong>dlow voltage lines.• Rugged steel basep<strong>an</strong> features deepdrawn duct connections <strong>an</strong>d emergencydrains.• Steeply sloped composite drainp<strong>an</strong> willempty fast <strong>an</strong>d never rust.• Ships in horizontal configuration <strong>an</strong>dconverts quickly for downflow.Table PG-7-A — 2YCC - XB13c - Convertible Package Gas/Electric - R-22CabinetModel AFUE (%) Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H x W x L2YCC – 208/230/1/602YCC3024A1040A 23,000 13.00/11.00 80 470 13.3 20 74 36 x 49 x 412YCC3024A1064A 23,000 13.00/11.00 80 481 13.3 20 74 36 x 49 x 412YCC3030A1040A 28,000 13.00/11.00 80 470 16.3 25 74 36 x 49 x 412YCC3030A1064A 28,000 13.00/11.00 80 481 16.3 25 74 36 x 49 x 412YCC3030A1075A 28,000 13.00/11.00 79.4 481 16.3 25 74 36 x 49 x 412YCC3036A1064A 35,000 13.00/11.00 80 479 23.0 35 76 36 x 49 x 412YCC3036A1075A 35,000 13.00/11.00 80 479 23.0 35 76 36 x 49 x 412YCC3036A1096A 35,000 13.00/11.00 80 485 23.0 35 76 36 x 49 x 412YCC3042A1064A 40,000 13.00/11.00 80 599 24.5 40 78 38 x 59 x 442YCC3042A1075A 40,000 13.00/11.00 80 599 24.5 40 78 38 x 59 x 442YCC3042A1096A 40,000 12.20/11.00 80 607 24.5 40 78 38 x 59 x 442YCC3048A1075A 47,000 13.00/11.00 80 656 29.0 45 77 38 x 59 x 442YCC3048A1096A 47,000 13.00/11.00 80 663 29.0 45 77 38 x 59 x 442YCC3048A1120A 47,000 13.00/11.00 80 669 29.0 45 77 38 x 59 x 442YCC3060A1096A 58,000 13.00/11.00 80 678 40.4 60 76 42 x 59 x 442YCC3060A1120A 58,000 13.00/11.00 80 684 40.4 60 76 42 x 59 x 44• Complete set of customized electricheaters designed for all models. Featuresa polarized plug for easy installation.• Optional filter rack kits fit inside the unit.Available for 1" or 2" media.• Non-bleed exp<strong>an</strong>sion valves on indoor<strong>an</strong>d outdoor coils.• Direct drive 2 <strong>an</strong>d 3 speed indoor blowermotors.• Pressure taps easily accessed <strong>an</strong>dprotected inside compressor compartment.• Easy access liquid line tap insidecompressor compartment.• St<strong>an</strong>dard operation to 55°F as m<strong>an</strong>ufactured.• Low ambient cooling to 0°F with kit.• UL approved <strong>an</strong>d listed.• 10 year heat exch<strong>an</strong>ger, 5 yearcompressor <strong>an</strong>d coil <strong>an</strong>d 5 year otherparts limited warr<strong>an</strong>ty.(<strong>Residential</strong> Use Only)• Optional extended warr<strong>an</strong>ty.For information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-7 Effective 1/1/06


Package Gas/ElectricConvertible 1½ through 5 Tons• All steel louvers <strong>an</strong>d cabinet for rugged,long lasting protection.• Stainless steel burners <strong>an</strong>d heat exch<strong>an</strong>gerfor extra long life <strong>an</strong>d safety.• Quiet operation delivers great in-homecomfort with minimal sound.Table PG-8-A — 4YCC - XB13c - Convertible Package Gas/Electric - R-410ACabinetModel AFUE (%) Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H x W x L4YCC – 208/230/1/604YCC3018A1040A 18,000 13.00/11.00 79.8 471 10.1 15 74 36 x 49 x 414YCC3036A1064A 35,000 13.00/11.00 80 488 23.6 35 75 36 x 49 x 414YCC3036A1075A 35,000 13.00/11.00 80 488 23.6 35 75 36 x 49 x 414YCC3036A1096A 35,000 13.00/11.00 80 493 23.6 35 75 36 x 49 x 414YCC3048A1075A 46,500 13.00/11.00 80 645 31.5 50 80 38 x 59 x 444YCC3048A1096A 46,500 13.00/11.00 80 653 31.5 50 80 38 x 59 x 444YCC3048A1120A 46,500 13.00/11.00 80 659 31.5 50 80 38 x 59 x 444YCC3060A1096A 58,000 13.00/10.95 80 670 43.3 60 79 40 x 59 x 444YCC3060A1120A 58,000 13.00/10.95 80 676 43.3 60 79 40 x 59 x 444YCC – 208/230/3/604YCC3036A3064A 35,000 13.00/11.00 80 488 18.5 30 75 36 x 49 x 414YCC3036A3075A 35,000 13.00/11.00 80 488 18.5 30 75 36 x 49 x 414YCC3036A3096A 35,000 13.00/11.00 80 493 18.5 30 75 36 x 49 x 414YCC3048A3075A 46,500 13.00/11.00 80 645 24.0 35 80 38 x 59 x 444YCC3048A3096A 46,500 13.00/11.00 80 653 24.0 35 80 38 x 59 x 444YCC3048A3120A 46,500 13.00/11.00 80 659 24.0 35 80 38 x 59 x 444YCC3060A3096A 58,000 13.00/10.95 80 670 31.5 50 79 40 x 59 x 444YCC3060A3120A 58,000 13.00/10.95 80 676 31.5 50 79 40 x 59 x 444YCC – 460/3/604YCC3036A4064A 35,000 13.00/11.00 80 488 8.7 15 75 36 x 49 x 414YCC3036A4075A 35,000 13.00/11.00 80 488 8.7 15 75 36 x 49 x 414YCC3036A4096A 35,000 13.00/11.00 80 493 8.7 15 75 36 x 49 x 414YCC3048A4075A 46,500 13.00/11.00 80 645 11.7 15 80 38 x 59 x 444YCC3048A4096A 46,500 13.00/11.00 80 653 11.7 15 80 38 x 59 x 444YCC3048A4120A 46,500 13.00/11.00 80 659 11.7 15 80 38 x 59 x 444YCC3060A4096A 58,000 13.00/10.95 80 678 19.3 25 79 40 x 59 x 444YCC3060A4120A 58,000 13.00/10.95 80 684 19.3 25 79 40 x 59 x 44Effective 1/1/06• Weather Beater Top contoured for greatappear<strong>an</strong>ce <strong>an</strong>d reinforced for strength.• Appli<strong>an</strong>ce grade finish of durable powderpaint baked on both sides of the p<strong>an</strong>els.• Exclusive Climatuff® high efficiencycompressor with internal overloadprotection.• High efficiency outdoor f<strong>an</strong> motor for quiet<strong>an</strong>d reliable operation.• Composite Vortica® blower providesbetter airflow <strong>an</strong>d less sound while usingless energy.• Spine Fin outdoor coil for long lastingperform<strong>an</strong>ce <strong>an</strong>d durability.• Right side electrical service for high <strong>an</strong>dlow voltage lines.• Rugged steel basep<strong>an</strong> features deepdrawn duct connections <strong>an</strong>d emergencydrains.• Steeply sloped composite drainp<strong>an</strong> willempty fast <strong>an</strong>d never rust.• Ships in horizontal configuration <strong>an</strong>dconverts quickly for downflow.PG-8• Complete set of customized electricheaters designed for all models.Features a polarized plug for easyinstallation.• Optional filter rack kits fit inside the unit.Available for 1" or 2" media.• Non-bleed exp<strong>an</strong>sion valves on indoor<strong>an</strong>d outdoor coils.• Direct drive 2 <strong>an</strong>d 3 speed indoor blowermotors.• Pressure taps easily accessed <strong>an</strong>dprotected inside compressor compartment.• Easy access liquid line tap insidecompressor compartment.• St<strong>an</strong>dard operation to 55°F as m<strong>an</strong>ufactured.• Low ambient cooling to 0°F with kit.• UL approved <strong>an</strong>d listed.• 10 year heat exch<strong>an</strong>ger, 5 yearcompressor <strong>an</strong>d coil <strong>an</strong>d 5 year otherparts limited warr<strong>an</strong>ty.(<strong>Residential</strong> Use Only)• Optional extended warr<strong>an</strong>ty.For information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Gas/ElectricConvertible 1½ through 5 Tons2/4YCC3018A through 2/4YCC3036AFor information on Roof Curbs <strong>an</strong>dRoof Curb Adaptors, please refer tothe Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-9 Effective 1/1/06


Package Gas/ElectricConvertible 1½ through 5 Tons2/4YCC3018A through 2/4YCC3036AFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.Effective 1/1/06PG-10For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Gas/ElectricConvertible 1½ through 5 Tons2/4YCC3042A through 2/4YCC3060AFor information on Roof Curbs <strong>an</strong>dRoof Curb Adaptors, please refer tothe Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-11 Effective 1/1/06


Package Gas/ElectricConvertible 1½ through 5 Tons2/4YCC3042A through 2/4YCC3060AFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.Effective 1/1/06PG-12For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Gas/ElectricConvertible 1½ through 5 Tons2YCX 4YCX 2YCC 4YCCTable PG-13-A — Accessories 2-5 1½-5 2-5 1½-5BAYADAP050A ...... Adapter Curb (Cabinet A/B) .................................................................................. 1½-3 1½-3 1½-3 1½-3BAYADAP051A ...... Adapter Curb (Cabinet C) ..................................................................................... 1½-3 1½-3 1½-3 1½-3BAYADAP052A ...... Adapter Curb (Cabinet A/B) .................................................................................. 3½-5 3½-5 3½-5 3½-5BAYADAP053A ...... Adapter Curb (Cabinet C) ..................................................................................... 3½-5 3½-5 3½-5 3½-5BAYADAP054A ...... Adapter Curb (Cabinet D) ..................................................................................... 3½-5 3½-5 3½-5 3½-5BAYCCHT101A ..... Cr<strong>an</strong>kcase Heater (230v) ..................................................................................... 2-2½, 3½-4 1½ 2-2½, 3½-4 1½BAYCCHT102A ..... Cr<strong>an</strong>kcase Heater (230v) ..................................................................................... 3 3,4,5 3 3,4,5BAYCCHT104A ..... Cr<strong>an</strong>kcase Heater (460v) ..................................................................................... — 3,4,5 — 3,4,5BAYCOVR112A ..... 12" Duct Shroud (Covers Horizontal Ducts)0 ....................................................... 1½-5 1½-5 1½-5 1½-5BAYCOVR118A ..... 18" Duct Shroud (Covers Horizontal Ducts)0 ....................................................... 1½-5 1½-5 1½-5 1½-5BAYCURB050A ..... Flat Roof Curb (Insulated)5 .................................................................................. 1½- 3 1½- 3 1½- 3 1½- 3BAYCURB051A ..... Flat Roof Curb (Insulated)6 .................................................................................. 3½-5 3½-5 3½-5 3½-5BAYDMPR101A ..... Motorized Fresh Air Damper14 ........................................................................... 1½- 3 1½- 3 1½- 3 1½- 3BAYDMPR102A ..... Motorized Fresh Air Damper14 ........................................................................... 3½-5 3½-5 3½-5 3½-5BAYECON101A ..... Economizer with Barometric Relief1347 ............................................................ 1½- 3 1½- 3 1½- 3 1½- 3BAYECON102A ..... Economizer with Barometric Relief1347 ............................................................ 3½-5 3½-5 3½-5 3½-5BAYECON200A ..... Economizer (Horizontal)137 ............................................................................... 1½- 3 1½- 3 1½- 3 1½- 3BAYECON201A ..... Economizer (Horizontal)137 ............................................................................... 3 ½-5 3 ½-5 3 ½-5 3 ½-5BAYENTH100A ..... Enthalpy Control Kit3 ........................................................................................... ✔ ✔ ✔ ✔BAYEXMK001A ..... Extreme Conditions Mounting Kit (Used on BAYCURB & BAYADAP) ................... ✔ ✔ ✔ ✔BAYEXMK002A ..... Extreme Conditions Mounting Kit (Used on BAYUTIL) .......................................... ✔ ✔ ✔ ✔BAYEXMK003A ..... Extreme Conditions Mounting Kit (Used on Slab Mounts) ..................................... ✔ ✔ ✔ ✔BAYFLTR101A ....... 1-2" Filter Frame (20x20 filter not included)1 ........................................................ 1½- 3 1½- 3 1½- 3 1½- 3BAYFLTR201A ....... 1-2" Filter Frame (20x20, 20x18 filters not included)1 .......................................... 3½-5 3½-5 3½-5 3½-5BAYLIFT002BA ..... Lifting Lug Kit ....................................................................................................... ✔ ✔ ✔ ✔BAYLOAM011A ..... Evaporator Defrost Control Kit .............................................................................. ✔ ✔ ✔ ✔BAYLOAM105A ..... Head Pressure Control ......................................................................................... ✔ ✔ ✔ ✔BAYLPKT100A ...... LP Conversion Kit ................................................................................................ 40K,120K 40K,120K 40K,120K 40K,120KBAYLPKT101A ...... LP Conversion Kit ................................................................................................ 64K, 96K 64K, 96K 64K, 96K 64K, 96KBAYLPKT102A ...... LP Conversion Kit ................................................................................................ 75K 75K 75K 75KBAYOSAH001A ..... M<strong>an</strong>ual Fresh Air Damper1 .................................................................................. 1½- 3 1½- 3 1½- 3 1½- 3BAYOSAH002A ..... M<strong>an</strong>ual Fresh Air Damper1 .................................................................................. 3½-5 3½-5 3½-5 3½-5BAYQSTK301A ..... Quick Start Kit ...................................................................................................... ✔ ✔ ✔ ✔BAYSQRD001A ..... 16" Round Duct Adapter9 .................................................................................... 1½- 3 1½- 3 1½- 3 1½- 3BAYSQRD002A ..... 18" Round Duct Adapter9 .................................................................................... 1½-5 1½-5 1½-5 1½-5BAYUTIL101A ....... Roof Curb Utility Extension Kit .............................................................................. 1½- 3 1½- 3 1½- 3 1½- 3BAYUTIL102A ....... Roof Curb Utility Extension Kit .............................................................................. 3½-5 3½-5 3½-5 3½-51 Must use filter frame when economizer/fresh air kit is used.2 Ships knocked down.3 Dry bulb control st<strong>an</strong>dard with economizer.4 Downflow Only.5 Full perimeter curb for 2/4YC*3018-036A.6 Full perimeter curb for 2/4YC*3042-060A.7 2-Stage thermostat provides additional energy savings if simult<strong>an</strong>eous economizer <strong>an</strong>d compressor operation is expected.8 Do not use with programmable thermostats.9 It is the responsibility of the installing dealer to properly size the ductwork for each specific application.0 BAYCOVR112,118A will not cover BAYSQRD002A applicationsFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-13 Effective 1/1/06


Package Gas/ElectricConvertible 1½ through 5 TonsYCZ – XL 1600YCY – XL 1400YCX – XL 1200Table PG-14-A — YCZ – XL 1600 Convertible Package Gas/ElectricCooling Heating Output Cabinet Supply/Return Supply/Return ShippingUnit Capacity Capacity Dimensions (in.) Downflow Horizontal Weight Max. SoundModel No. SEER/EER* (Btuh) (Btuh) AFUE% H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.YCZ – 208-230/1/60 Stage 1 - Stage 2YCZ036F1M0B 16.05/12.00 36,000 45,000 – 57,000 80 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 588 27.1 40 80 R1/ 2YCZ050F1H0A 16.00/11.60 51,000 73,000 – 95,500 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 693 32 40 82 R1YCZ060F1M0B 15.20/11.00 59,000 72,000 – 96,000 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 723 43.5 70 84 R1 /2YCZ – 208-230/3/60 Stage 1 - Stage 2YCZ036F3M0B 16.05/12.00 36,000 45,000 – 57,000 80 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 588 19.6 30 80 R1/ 2YCZ050F3H0A 16.00/11.60 51,000 73,000 – 95,500 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 693 26 30 82 R1YCZ060F3M0B 15.20/11.00 59,000 72,000 – 96,000 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 723 30.9 45 84 R1/ 2YCZ – 460/3/60 Stage 1 - Stage 2YCZ036F4M0A 15.60 36,000 45,000 – 57,000 80 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 613 11.4 15 80 R1/ 2YCZ050F4H0A 14.00 51,000 73,000 – 95,500 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 718 15.1 20 82 R1YCZ060F4M0A 14.85 59,000 72,000 – 96,000 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 748 20.3 30 82 R1/ 2Table PG-14-B — YCY – XL 1400 Convertible Package Gas/ElectricCooling Heating Output Cabinet Supply/Return Supply/Return ShippingUnit Capacity Capacity Dimensions (in.) Downflow Horizontal Weight Max. SoundModel No. SEER/EER* (Btuh) (Btuh) AFUE% H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.YCY – 208-230/1/60 Stage 1 - Stage 2YCY024G1L0A 14.00/12.00 24,000 30,000 – 37,000 80 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 444 15.9 25 80 R1YCY024G1M0A 14.00/12.00 24,000 44,000 – 53,000 80 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 455 15.9 25 80 R1YCY030G1L0A 13.00/11.00 30,600 31,000 – 38,000 80 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 474 21.4 30 80 R2YCY030G1M0A 13.00/11.00 30,600 44,000 – 55,000 80 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 485 21.4 30 80 R2YCY036G1M0A 14.00/12.00 36,000 45,000 – 57,000 80 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 508 24.8 40 80 R2YCY036G1H0A 14.00/12.00 36,000 61,000 – 72,000 80 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 513 24.8 40 80 R2YCY042G1M0A 14.00/11.70 41,500 65,000 – 78,000 80 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 513 26.7 40 80 R2YCY048G1H0A 14.40/12.20 49,000 73,000 – 95,500 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 639 32.7 45 84 R2YCY060G1M0A 13.00/11.00 61,000 72,000 – 96,000 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 659 46.8 70 84 STable PG-14-C — YCX – XL 1200 Convertible Package Gas/ElectricCooling Heating Output Cabinet Supply/Return Supply/Return ShippingUnit Capacity Capacity Dimensions (in.) Downflow Horizontal Weight Max. SoundModel No. SEER/EER* (Btuh) (Btuh) AFUE% H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.YCX – 208-230/1/60YCX024G1L0B 12.00/10.50 24,500 30,000-38,000 80 25 x 36 x 56 (A/B) 10 x 17 1 /2 18 9 /16 x 11 1 /16 380 15.6 25 80 R1YCX024G1M0B 12.00/10.50 24,500 46,000-57,000 80 29 x 36 x 56 (A/B) 10 x 17 1 /2 18 9 /16 x 11 1 /16 397 15.6 25 80 R1YCX030G1L0A 12.05/10.90 30,600 30,000-38,000 80 29 x 36 x 56 (B) 10 x 17 1 /2 18 9 /16x 11 1 /16 396 20.3 30 80 SYCX030G1M0A 12.05/10.90PHASED30,600 44,000-56,000 80 29 x 36 x 56 (B) 10 x 17 1 OUT/2 18 9 /16 x 11 1 /16 403 20.3 30 80 SYCX036G1L0A 12.05/10.50 37,000 32,000-39,000 80 29 x 36 x 56 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 412 24.0 40 80 SYCX036G1M0A 12.05/10.50 37,000 48,000-57,000 80 29 x 36 x 56 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 419 24.0 40 80 SYCX036G1H0A 12.05/10.50 37,000 60,000-76,000 80 29 x 36 x 64 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 440 24.0 40 80 SYCX042G1M0A 12.05/10.55 43,000 60,000-76,000 80 29 x 36 x 64 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 454 27.9 45 80 SYCX048G1H0A 12.50/11.45 48,000 78,000-95,000 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 582 31.1 45 84 SYCX060G1M0A 12.05/10.55 61,500 80,000-97,000 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 609 43.7 70 84 S1 Low/High output - Unit ships st<strong>an</strong>dard high heat configuration. Low-fire operation requires optional BAYLOFR001-007 kit.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = ScrollFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors, please refer to the Accessories/Information Tab.For complete equipment / combinationEffective 1/1/06PG-14selections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Gas/ElectricConvertible 2 through 5 TonsYCX – XL 1200YCP – XE 1200Table PG-15-A — YCX – XL 1200 Convertible Package Gas/ElectricCooling Heating Output1 Cabinet Supply/Return Supply/Return ShippingUnit Capacity Capacity Dimensions (in.) Downflow Horizontal Weight Max. SoundModel No. SEER/EER* (Btuh) (Btuh) AFUE% H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.YCX – 208-230/3/60YCX036G3L0A 12.05/10.5 37,000 32,000-39,000 80 29 x 36 x 56 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 412 17.4 25 80 SYCX036G3M0A 12.05/10.50 37,000 48,000-57,000 80 29 x 36 x 56 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 419 17.4 25 80 SYCX036G3H0A 12.05/10.50 37,000 60,000-76,000 80 29 x 36 x 64 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 440 17.4 25 80 SYCX042G3M0A 12.05/10.55PHASED43,000 60,000-76,000 80 29 x 36 x 64 (C) 10 x 17 1 OUT/2 18 9 /16 x 11 1 /16 454 19.9 30 80 SYCX048G3H0A 12.50/11.45 48,000 78,000-95,000 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 582 24.5 35 84 SYCX060G3M0A 12.05/10.55 61,500 80,000-97,000 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 609 30.6 45 84 SYCX – 460/3/60YCX036G4H0A 12.05/10.50 37,000 60,000-76,000 80 29 x 36 x 64 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 440 10.0 15 80 SYCX048G4H0A 12.50/11.45 48,000 78,000-95,000 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 582 15.4 20 84 SYCX060G4M0A 12.05/10.55 61,500 80,000-97,000 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 609 15.1 20 84 STable PG-15-B — YCP – XE 1200 Convertible Package Gas/ElectricCooling Heating Output1 Cabinet Supply/Return Supply/Return ShippingUnit Capacity Capacity Dimensions (in.) Downflow Horizontal Weight Max. SoundModel No. SEER/EER* (Btuh) (Btuh) AFUE% H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.YCP – 208-230/1/60YCP024F1L0B 12.00/10.50 24,200 30,000 – 38,000 80 25 x 36 x 56 (A/B) 10 x 17 1 /2 18 9 /16 x 11 1 /16 380 14.6 20 80 R1YCP024F1M0B 12.00/10.50 24,000 46,000 – 57,000 80 29 x 36 x 56 (A/B) 10 x 17 1 /2 18 9 /16 x 11 1 /16 397 14.8 20 80 R1YCP030F1L0A 12.00/10.90 30,000 30,000 – 38,000 80 29 x 36 x 56 (A/B) 10 x 17 1 /2 18 9 /16 x 11 1 /16 396 21.2 30 80 SYCP030F1M0A 12.00/10.90 30,000 44,000 – 56,000 80 29 x 36 x 56 (A/B) 10 x 17 1 /2 18 9 /16 x 11 1 /16 403 21.2 30 80 SYCP036F1L0A 12.00/10.50 36,000 32,000 – 39,000 80 29 x 36 x 56 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 412 24.4 40 80 SYCP036F1M0A 12.0010.50 36,000 48,000 – 57,000 80 29 x 36 x 56 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 419 24.4 40 80 SYCP036F1H0A 12.00/10.50 36,000 60,000 – 76,000 80 29 x 36 x 64 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 440 24.4 40 80 SYCP042F1M0A 12.00/10.55 42,000 60,000 – 76,000 80 29 x 36 x 64 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 454 26.8 40 80 SYCP048F1H0A 12.20/11.45 47,000 78,000 – 95,000 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 582 31.9 50 84 SYCP060F1M0A 12.00/10.55 60,000 80,000 – 97,000 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 609 45.0 70 84 SYCP – 208-230/3/60YCP036F3L0A 12.00/10.50 36,000 32,000 – 39,000 80 29 x 36 x 56 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 412 17.4 25 80 SYCP036F3M0A 12.00/10.50 36,000 48,000 – 57,000 80 29 x 36 x 56 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 419 17.4 25 80 SYCP036F3H0A 12.00/10.50 36,000 60,000 – 76,000 80 29 x 36 x 64 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 440 17.4 25 80 SYCP042F3M0A 12.00/10.55 42,000 60,000 – 76,000 80 29 x 36 x 64 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 454 19.9 30 80 SYCP048F3H0A 12.20/11.45 47,000 78,000 – 95,000 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 582 24.5 35 84 SYCP060F3M0A 12.00/10.55 60,000 80,000 – 97,000 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 609 30.6 45 84 SYCP – 460/3/60YCP036F4H0A 12.00/10.50 36,000 60,000 – 76,000 80 29 x 36 x 64 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 440 10.0 15 80 SYCP048F4H0A 12.20/11.45 47,000 78,000 – 95,000 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 582 15.4 20 84 SYCP060F4M0A 12.00/10.55 60,000 80,000 – 97,000 80 33 x 45 x 65 (D) 14 x 20 21 1 /16 x 15 1 /16 609 15.1 20 84 SFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PHASED OUT1 Low/High output - Unit ships st<strong>an</strong>dard high heat configuration. Low-fire operation requires optional BAYLOFR001-007 kit.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = ScrollFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.PG-15 Effective 1/1/06


Package Gas/ElectricConvertible 1½ through 5 TonsYCC – XE 1000Table PG-16-A —YCC – XE 1000 Convertible Package Gas/ElectricCooling Heating Output1 Cabinet Supply/Return Supply/Return ShippingUnit Capacity Capacity Dimensions (in.) Downflow Horizontal Weight Max. SoundModel No. SEER/EER* (Btuh) (Btuh) AFUE% H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.YCC – 208-230/1/60YCC018F1L0B 10.00/9.35 18,000 32,000-40,000 78 25 x 36 x 55 (A) 10 x 17 1 /2 18 9 /16 x 11 1 /16 341 13.2 20 80 R1YCC024F1L0B 10.00/9.10 23,400 32,000-40,000 78 25 x 36 x 55 (A) 10 x 17 1 /2 18 9 /16 x 11 1 /16 350 15.7 25 80 R1YCC030F1L0B 10.00/9.20 29,200 32,000-40,000 78 25 x 36 x 55 (A/B) 10 x 17 1 /2 18 9 /16 x 11 1 /16 398 20.1 30 80 R1YCC030F1M0B 10.00/9.20 29,800 48,000-60,000 78 29 x 36 x 55 (A/B) 10 x 17 1 /2 18 9 /16 x 11 1 /16 398 21.3 35 80 R1PHASED OUTYCC036F1L0B 10.00/8.75 35,200 32,000-40,000 78 29 x 36 x 55 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 420 25.2 40 80 R1/2YCC036F1M0B 10.00/8.75 35,200 48,000-60,000 78 29 x 36 x 55 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 426 25.2 40 80 R1/2YCC036F1H0B 10.00/8.75 35,200 64,000-80,000 78 29 x 36 x 63 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 454 25.2 40 80 R1/2YCC042F1M0B 10.00/9.50 42,000 64,000-80,000 78 29 x 36 x 63 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 454 30.2 50 80 R2YCC048F1M0B 10.00/9.25 46,500 64,000-80,000 78 29 x 36 x 63 (C/D) 10 x 17 1 /2 18 9 /16 x 11 1 /16 461 33 50 80 R2YCC048F1H0B 10.00/9.25 48,000 80,000-100,000 78 33 x 45 x 64 (C/D) 14 x 20 21 1 /16 x 15 1 /16 576 34.4 50 84 R2YCC060F1M0B 10.00/9.20 60,000 80,000-100,000 78 33 x 45 x 64 (D) 14 x 20 21 1 /16 x 15 1 /16 604 43.9 70 84 R2YCC – 208-230/3/60 - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.YCC036F3L0B 10.00/8.75 35,400 32,000-40,000 78 29 x 36 x 55 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 420 18 25 80 R1/2YCC036F3M0B 10.00/8.75 35,400 48,000-60,000 78 29 x 36 x 55 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 426 18 25 80 R1/2YCC036F3H0B 10.008.75 35,400 64,000-80,000 78 29 x 36 x 63 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 454 18 25 80 R1/2YCC042F3M0B 10.00/9.50 42,000 64,000-80,000 78 29 x 36 x 63 (C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 454 22 35 80 R2YCC048F3M0B 10.00/9.25 46,500 64,000-80,000 78 29 x 36 x 63 (C/D) 10 x 17 1 /2 18 9 /16 x 11 1 /16 461 24.8 40 84 R2YCC048F3H0B 10.00/9.25 48,000 80,000-100,000 78 33 x 45 x 64 (C/D) 14 x 20 21 1 /16 x 15 1 /16 576 26.8 40 84 R2YCC060F3M0B 10.00/9.20 60,000 80,000-100,000 78 33 x 45 x 64 (D) 14 x 20 21 1 /16 x 15 1 /16 604 31 45 84 R2YCC – 460/3/60 - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.YCC036F4H0B 10.00/8.75 35,400 64,000-80,000 78 29 x 36 x 63 (B/C) 10 x 17 1 /2 18 9 /16 x 11 1 /16 454 8 15 80 R1/2YCC048F4H0B 10.00/9.25 48,000 80,000-100,000 78 33 x 45 x 64 (C/D) 14 x 20 21 1 /16 x 15 1 /16 576 12.2 15 84 R2YCC060F4M0B 10.00/9.20 60,000 80,000-100,000 78 33 x 45 x 64 (D) 14 x 20 21 1 /16 x 15 1 /16 604 15.6 25 84 R21 Low/High output - Unit ships st<strong>an</strong>dard high heat configuration. Low-fire operation requires optional BAYLOFR001-007 kit.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = ScrollFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.Effective 1/1/06PG-16For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Gas/ElectricConvertible 1½ through 5 TonsYCZ YCY-G YCX-G YCP-F YCC-FTable PG-17-A — Features 3-5 Ton 2-5 Ton 2-5 Ton 2-5 Ton 1 1 /2-5 Ton• Climatuff® Compressor (2) ........................................................................................................ ✔ — — — —• Climatuff® Compressor (1) ........................................................................................................ — ✔ ✔ ✔ ✔• Coil Sav’R TM guard ...................................................................................................................... ✔ ✔ ✔ — —• Comfort "R" mode option ....................................................................................................... ✔ ✔ — — —• Aluminized steel tubular heat exch<strong>an</strong>ger ..................................................................................... ✔ ✔ ✔ ✔ ✔• Direct spark ignition ..................................................................................................................... ✔ ✔ ✔ ✔ ✔• Dual firing rates (w/optional accessory) ...................................................................................... — — ✔ ✔ ✔• GE ECM variable speed f<strong>an</strong> ........................................................................................................ ✔ ✔ — — —• Heavy Vinyl - coated coil guard ................................................................................................... — — — ✔ —• Horizontal convertible to downflow .............................................................................................. ✔ ✔ ✔ ✔ ✔• Lite Port/Stored diagnostics ......................................................................................................... ✔ ✔ ✔ ✔ ✔• L.P. convertible ............................................................................................................................. ✔ ✔ ✔ ✔ ✔• Meets California NOX (as shipped) ............................................................................................. ✔ ✔ ✔ ✔ ✔• Multi-port in-shot burner .............................................................................................................. ✔ ✔ ✔ ✔ ✔• Plate Fin coils .............................................................................................................................. ✔ ✔ ✔ ✔ ✔• Two-stage cooling ........................................................................................................................ ✔ — — — —• Two-stage gas valve .................................................................................................................... ✔ ✔ — — —• 5-year limited compressor only warr<strong>an</strong>ty (Commercial use) ........................................................ ✔ ✔ ✔ ✔ ✔• 5-year limited compressor <strong>an</strong>d outdoor coil warr<strong>an</strong>ty (<strong>Residential</strong> use) ...................................... — — — ✔ ✔• 5-year limited heat exch<strong>an</strong>ger warr<strong>an</strong>ty (Commercial use) ......................................................... ✔ ✔ ✔ ✔ ✔• 5-year limited parts warr<strong>an</strong>ty (<strong>Residential</strong> use) ........................................................................... ✔ ✔ ✔ ✔ ✔• 1-year limited parts warr<strong>an</strong>ty (Commercial use) .......................................................................... ✔ ✔ ✔ ✔ ✔• 10-year limited compressor <strong>an</strong>d outdoor coil warr<strong>an</strong>ty (<strong>Residential</strong> use) .................................... ✔ ✔ ✔ — —• 10-year limited heat exch<strong>an</strong>ger warr<strong>an</strong>ty (<strong>Residential</strong> use) ......................................................... — — — ✔ ✔• 20-year limited heat exch<strong>an</strong>ger warr<strong>an</strong>ty (<strong>Residential</strong> use) ......................................................... ✔ ✔ ✔ — —Table PG-17-B — Comfort ControlsFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PHASED OUTAY28X092 ............. Heat/Cool (Horizontal) ...................................................................................... ✔ ✔ ✔BAY28X1821 ....... 1-Stage Htg/Clg ................................................................................................ ✔ ✔ ✔BAY28X1831 ...... 2-Stage Htg/Clg ................................................................................................ ✔ ✔ ✔BAY28X184 ........... Subbase Auto/M<strong>an</strong>ual Ch<strong>an</strong>geover .................................................................. ✔ ✔ ✔BAY28X187 ........... Subbase Auto Ch<strong>an</strong>geover ............................................................................... ✔ ✔ ✔BAY28X190 ........... Locking Thermostat Cover for Room Thermostat .............................................. ✔ ✔ ✔BAYBASE006A ...... Used w/BAYSTAT040B, 2 Htg / 2 Clg w/Economizer ........................................ ✔ ✔ ✔BAYBASE008A ...... Used w/BAYSTAT040B, 1 Htg / 1 Clg ............................................................... ✔ ✔ ✔BAYCOVR100A ..... Wall Cover Plate ............................................................................................... ✔ ✔ ✔BAYSTAT008 ......... M<strong>an</strong>ual 1-Stage Htg/Clg ................................................................................... ✔ ✔ ✔BAYSTAT010 ......... Auto 2-Stage Heating/Cooling .......................................................................... ✔ ✔ ✔BAYSTAT012 ......... M<strong>an</strong>ual 1-Stage Htg/2-Stage Clg w/Economizer ............................................... ✔ ✔ ✔BAYSTAT040B ....... Programmable (used with BAYBASE) ............................................................... ✔ ✔ ✔BAYSTAT253A ....... Humidity Control ............................................................................................... — — —BAYSTAT305 ......... Heat/Cool (Vertical) .......................................................................................... ✔ ✔ ✔TAYSENS100A2 ... Outdoor Temp. Sensor (with case) .................................................................... ✔ ✔ ✔TAYSTAT241 .......... M<strong>an</strong>ual 2-Stage Htg/1-Stage Clg ...................................................................... ✔ ✔ ✔TAYSTAT300C ....... 7 day Programmable 1 Htg/1 Clg ...................................................................... ✔ ✔ ✔TAYSTAT302C ....... 7 day Programmable 2 Htg/2 Clg w/Economizer ............................................... ✔ ✔ ✔TAYSTAT340 .......... Prog., 5/2 Day, M<strong>an</strong>ual, 1Htg/1 Clg ................................................................... ✔ ✔ ✔TAYSTAT350 .......... Prog., 5/2 Day, M<strong>an</strong>ual, 2 (Gas)Htg/1 Clg ......................................................... ✔ ✔ ✔TAYSTAT370 .......... Electronic, Auto 1 Htg (Gas)/ 1Clg (Non Prog) .................................................. ✔ ✔ ✔TAYSTAT375 .......... Electronic, 2 Htg/ 2Clg (Non Prog) .................................................................... ✔ ✔ ✔TAYSTAT380 .......... Electronic, 2 Htg (Gas)/ 1Clg (Non Prog) .......................................................... — — —TCONT200A .......... 1Htg /1Clg (Gas, Oil or Electric) ........................................................................ ✔ ✔ ✔TCONT401A .......... 2Htg /1Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔TCONT402A .......... 3Htg /2Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔TCONT600A .......... 1Htg /1Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔TCONT602A .......... 2Htg /2Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔TCONT800A .......... 1Htg /1Clg (Gas, Oil or Electric) ........................................................................ ✔ ✔ ✔TCONT802A .......... 3Htg /2Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔TCONT803A .......... 3Htg /2Clg (Heat Pump/A/C) w/Humidity Control .............................................. ✔ ✔ ✔See Comfort Controls/Zone Sensors Section1 Requires Subbase.2 Used with TAYSTAT300C <strong>an</strong>d TAYSTAT302C only.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.See Comfort Controls/Zone Sensors SectionPHASED OUTFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.PG-17 Effective 1/1/06


Package Gas/ElectricConvertible 1½ through 5 TonsYCZ-F YCY-G YCX-G YCP-F YCC-FTable PG-18-A — Accessories 3-5 2-5 2-5 2-5 1 1 /2-5BAYASCT00178 .... Anti-Short Cycle Timer ..................................................................................... 3-5 2-5 2-5 2-5 1½-5BAYCCHT003A ...... Cr<strong>an</strong>kcase Heater (230v)1 ............................................................................. — 2-3½ 2 2 1½-5BAYCCHT202A ...... Cr<strong>an</strong>kcase Heater (230v) ................................................................................. — 2½-5 2½-5 2½-5 —BAYCCHT400A ...... Cr<strong>an</strong>kcase Heater (460v) ................................................................................. — — 2½-5 2½-5 —BAYCURB030A ...... Roof Curb (Flat Roof)3 (14 H x 34 W x 53 1 /8 L) ............................................... 3-5 3-5 2-5 2-5 1½-5BAYCURB033A ...... Roof Curb (Flat Roof)3Acousti-Curb (14 H x 34 W x 60 5 /8 L) .......................... 3 2-3½ 3½ M/H 36H-42M 3H,3½-4MBAYCURB034A ...... Roof Curb (Flat Roof)3 Acousti-Curb (14 H x 43 W x 62 1 /16 L) .......................... 4-5 4-5 4-5 4-5 4H, 5MBAYCURB038A ...... Roof Curb (Flat Roof)3Acousti-Curb (14 H x 34 W x 53 1 /8 L) .......................... 3-5 2-5 2-5 2-5 1½-5BAYDMPR040A ..... 0-25% M<strong>an</strong>ual Fresh Air Damper (Downflow Only)2 ...................................... 3 2-3½ 2-3½ 2-3½ 1½-4MBAYDMPR041A ..... 0-25% M<strong>an</strong>ual Fresh Air Damper (Downflow Only)2 ...................................... 4-5 4-5 4-5 4-5 4H-5MBAYDMPR050A ..... Motorized Fresh Air Damper ............................................................................ — — 4H-5M 4H-5M 4H-5MBAYDUCT004A ...... 12" Round Duct Adapters (2 per Box) Horizontal Only ..................................... 3 2-3½ 2-3½ 2-3½ 1½-4MBAYDUCT005A ...... 14" Round Duct Adapters (1 per Box) Horizontal Only ..................................... 4 2-3½ 2-3½ 2-3½ 1½-4MBAYECMT002A ...... Extreme Conditions Mouniting Kit (Curb Mount) .............................................. 3-5 2-5 2-5 2-5 1½-5BAYECMT003A ...... Extreme Conditions Mouniting Kit (Slab or Rack Mount) ................................. 3-5 2-5 2-5 2-5 1½-5BAYECON054B ...... 0-100% Mod. Economizer with Bar Relief – Downflow246 ............................ 3 2-3½ 2-3½ 2-3½ 1½-4MBAYECON055B ...... 0-100% Mod. Economizer with Bar Relief – Downflow246 ........................... 4-5 4-5 4-5 4-5 4H, 5MBAYECON073A ...... 0-100% Mod. Economizer – Horizontal246 .................................................. 3-5 2-5 2-5 2-5 1½-5BAYENTH001A ...... Enthalpy Control (Solid State)4 ...................................................................... 3-5 2-5 2-5 2-5 1½-5BAYFLTR012A ....... Filter Frame2 (20 x 25 x 1" filter not included) ................................................ — — 2-3½M 2-3½M 2½M-3LMBAYFLTR013A ....... Filter Frame2 (20 x 25 x 1" filter not included) ................................................ 3 2-3½LMH 3H-3½M 3H-3½M 3H,3½-4MBAYFLTR014A ....... Filter Frame2 (3-10 x 25 x 1" filter not included) ............................................. 4H-5M 4H-5M 4H-5M 4H-5M 4H-5MBAYFLTR015A ....... Filter Frame2 (20 x 20 x 1" filter not included) ................................................ — — 2L 2L 1½-2½LBAYFLTR017A ....... Filter Frame2 (20 x 25 x 2" filter not included) ................................................ — — 2-3½M 2-3½M 2½M-3LMBAYFLTR018A ....... Filter Frame2 (20 x 25 x 2" filter not included) ................................................ 3 2-3½LMH 3H-3½M 3H-3½M 3H-3½-4MBAYFLTR019A ....... Filter Frame2 (2-16 x 25 x 2" filter not included) ............................................. 4H-5M 4H-5M 4H-5M 4H-5M 4H-5MBAYGARD016A ...... Condenser Coil Guard ..................................................................................... — — — — 1½-2½LBAYGARD017A ...... Condenser Coil Guard ..................................................................................... — — — — 3½-4MBAYGARD018A ...... Condenser Coil Guard ..................................................................................... — — — — 2½M-3HBAYGARD021A ...... Condenser Coil Guard ..................................................................................... — — — — 4H-5MBAYHSMT043A ...... High Static Motor (230/460V) 3/4HP ................................................................ — — 2½-3½ 2½-3½ 2½-3½BAYHSMT044A ...... High Static Motor (230/460V) 1HP ................................................................... — — 4-5 4-5 4-5BAYHSMT045A ...... High Static Motor (208V) 1HP .......................................................................... — — 4-5 4-5 4-5BAYHSMT056A ...... High Static Motor (208V) 3/4HP ....................................................................... — — 2½-3½ 2½-3½ 2½-3½BAYINDK001A* ...... Insulated Deck P<strong>an</strong> for A & B Cabinet .............................................................. — — 2-3LM 2-3LM 1½-3LMBAYINDK002A** ..... Insulated Deck P<strong>an</strong> for C Cabinet .................................................................... 3M 2-3½LMH 3H-3½M 3H-3½M 3H,3½-4MBAYINDK003A*** ... Insulated Deck P<strong>an</strong> for D Cabinet .................................................................... 4H-5M 4H-5M 4H-5M 4H-5M 4H-5MBAYKSKT010A ....... Quick Start Kit for (Single Phase Units) ........................................................... — — — — 1½-5BAYKSKT254 ......... Start Kit-Scroll Models Only (Single Phase Only) ............................................ — — 2½-4 2½-4 —BAYLIFT002B ......... Lifting Lug Kit .................................................................................................. 3-5 2-5 2-5 2-5 1½-5BAYLOAM011A ...... Evaporator Defrost Control Kit1 ....................................................................... 3-5 2-5 2-5 2-5 1½-5BAYLOAM323A ...... Head Pressure Control15 ............................................................................... — 2-5 2-5 2-5 1½-5BAYLOFR001B ...... Low Fire Kit ...................................................................................................... — — 1½-3L 1½-3L 1½-3LBAYLOFR002B ...... Low Fire Kit ...................................................................................................... — — 2M 2M 2MBAYLOFR003B ...... Low Fire Kit ...................................................................................................... — — 2½-3M 2½-3M 2½-3MBAYLOFR004B ...... Low Fire Kit ...................................................................................................... — — 3H,3½M 3H,3½M 3H,3½M-4MBAYLOFR005B ...... Low Fire Kit ...................................................................................................... — — — — —BAYLOFR006B ...... Low Fire Kit ...................................................................................................... — — 4-5 4-5 —BAYLOFR007B ...... Low Fire Kit ...................................................................................................... — — — — 4-5M, 4HBAYLPKT022A ....... LP Conversion Kit ............................................................................................ — — 2-5 2-5 1½-5BAYLPKT024C ....... LP Conversion Kit ............................................................................................ 3-5 2-5 — — —BAYLPSS001A ....... LP Conversion Kit with 5 Stainless steel burners ............................................. — — 2-5 2-5 1½-5<strong>an</strong>d 5 LP #54 orifices (Single Stage)BAYLPSS002A ....... LP Conversion Kit with 5 Stainless steel burners ............................................. 3-5 2-5 — — —<strong>an</strong>d 5 LP #54 orifices (Two Stage)BAYMOTR307A ...... 208-230V 1/2HP Ball Bearing OD Motor used with BAYLOAM323A .............................. — 2-5 2-5 2-5 1½-5BAYMOTR406A ...... 460V 1/2HP Ball Bearing OD Motor used with BAYLOAM323A ............................ — — 2-5 2-5 1½-5BAYOSAC001A ...... Outside Air Econo Controller ............................................................................ 3-5 — — — —BAYSTAT023 .......... Remote Potentiometer for BAYECON054B, 055B ............................................ 3-5 2-5 2-5 2-5 1½-5BAYUTIL030A ........ Roof Curb Utility Extension Kit for BAYCURB030, 038A .................................. — — — — 1½-5BAYUTIL033A ........ Roof Curb Utility Extension Kit for BAYCURB033A .......................................... — — — — 3H,3½-4MBAYUTIL034A ........ Roof Curb Utility Extension Kit for BAYCURB034A .......................................... — — — — 4H, 5M1 Low ambient cooling requires cr<strong>an</strong>kcase heater.7 Activated on Power Off.2 Must use filter frame when economizer/fresh air kit is used.8 Not for use with programmable thermostat.3 Ships knocked down.* Currently Shipped with BAYCURB038A.4 Dry bulb control st<strong>an</strong>dard with economizer.** Currently Shipped with BAYCURB033A.5 May require motor ch<strong>an</strong>ge, see instruction guide.*** Currently Shipped with BAYCURB034A.6 2-Stage thermostat provides additional energy savings if simult<strong>an</strong>eous economizer L – Low heat model<strong>an</strong>d compressor operation is expected.M – Medium heat modelEffective 1/1/06H – High heat modelPG-18PHASED OUTFor information on Roof Curbs<strong>an</strong>d Roof Curb Adaptors, pleaserefer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Package Gas/ElectricConvertible 2 through 5 TonsBASUPPLY &RETURN PANELEVAPORATOR COIL &BLOWER PANELCCENTER OFGRAVITYEFEGHECONOMIZER/FILTERACCESS PANEL67 MM (2 5/8")KHORIZONTALSUPPLYOPENINGJ35 MM(1 3/8")DOWNFLOWSUPPLYOPENINGDLPMHORIZONTALRETURN OPENINGDXXLMNYY76 MM(3")59 MM (2 5/16")48 MM (1 7/8") DIA. ENTRYFOR 13 MM (1/2) NPTGAS CONNECTION29 MM(1 1/8")CONDENSATE DRAIN19 MM (3/4") FEMALE NPTDOWNFLOWRETURN OPENINGTable PG-19-A — YCZ – XL 1600 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0YCZ036F-M 64 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 18 1 /2 25 1 /2 17 1 /2 10 3 8 3 /4 33AYCZ050F-H 65 1 /8 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 24 26 1 /2 20 14 3 1 /2 8 5 /16 34AYCZ060F-M 65 1 /8 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 22 3 /4 25 1 /2 20 14 3 1 /2 8 5 /16 34ATable PG-19-B — YCY – XL 1400 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0YCY024G-L 64 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 20 5 /16 29 1 /2 17 1 /2 10 3 8 3 /4 30A, 38A, 33AYCY024G-M 64 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 21 1 /2 29 1 /2 17 1 /2 10 3 8 3 /4 30A, 38A, 33AYCY030G-L 64 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 19 5 /16 28 1 /2 17 1 /2 10 3 8 3 /4 30A, 38A, 33AYCY030G-M 64 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 19 5 /16 28 1 /2 17 1 /2 10 3 8 3 /4 30A, 38A, 33AYCY036G-M 64 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 19 1 /2 28 7 /32 17 1 /2 10 3 8 3 /4 30A, 38A, 33AYCY036G-H 64 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 19 13 /16 28 1 /2 17 1 /2 10 3 8 3 /4 30A, 38A, 33AYCY042G-M 64 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 19 13 /16 28 1 /2 17 1 /2 10 3 8 3 /4 30A, 38A, 33AYCY048G-H 65 1 /8 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 25 29 7 /32 20 14 3 1 /2 8 5 /16 30A, 38A, 34AYCY060G-M 65 1 /8 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 25 29 7 /32 20 14 3 1 /2 8 5 /16 30A, 38A, 34ATable PG-19-C — YCX – XL 1200 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0YCX024G-L 56 1 /2 36 25 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 5 /16 25 17 1 /2 10 3 4 7 /16 30A, 38AYCX030G-L 56 1 /2 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 20 3 /4 25 13 /16 17 1 /2 10 3 4 7 /16 30A, 38AYCX036G-L 56 1 /2 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 19 3 /4 24 13 /16 17 1 /2 10 3 4 7 /16 30A, 38AYCX024G-M 56 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 21 1 /2 23 17 1 /2 10 3 8 3 /4 30A, 38AYCX030G-M 56 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 20 1 /2 25 17 1 /2 10 3 8 3 /4 30A, 38APHASED OUTYCX036G-M 56 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 19 1 /2 27 15 /16 17 1 /2 10 3 8 3 /4 30A, 38AYCX036G-H 64 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 19 3 /4 28 1 /4 17 1 /2 10 3 8 3 /4 30A, 38A, 33AYCX042G-M 64 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 19 3 /4 28 1 /4 17 1 /2 10 3 8 3 /4 30A, 38A, 33AYCX048G-H 64 5 /16 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 25 29 1 /2 20 14 3 1 /2 8 15 /16 30A, 38A, 34AYCX060G-M 64 5 /16 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 25 29 1 /2 20 14 3 1 /2 8 15 /16 30A, 38A, 34AFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-19 Effective 1/1/06


Package Gas/ElectricConvertible 1½ through 5 TonsBASUPPLY &RETURN PANELEVAPORATOR COIL &BLOWER PANELCCENTER OFGRAVITYEFEGHECONOMIZER/FILTERACCESS PANEL67 MM (2 5/8")KHORIZONTALSUPPLYOPENINGJ35 MM(1 3/8")DOWNFLOWSUPPLYOPENINGDLPMHORIZONTALRETURN OPENINGDXXLMNYY76 MM(3")59 MM (2 5/16")48 MM (1 7/8") DIA. ENTRYFOR 13 MM (1/2) NPTGAS CONNECTION29 MM(1 1/8")CONDENSATE DRAIN19 MM (3/4") FEMALE NPTDOWNFLOWRETURN OPENINGTable PG-20-A — YCP – XE 1200 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0YCP024F-L 56½ 36 25 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 21¼ 17 1 /2 10 3 4 7 /16 30A, 38AYCP024F-M 56½ 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 21 7 /8 17 1 /2 10 3 4 7 /16 30A, 38AYCP030F-L 56½ 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 21 7 /8 17 1 /2 10 3 4 7 /16 30A, 38AYCP030F-M 56½ 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 21 7 /8 17 1 /2 10 3 4 7 /16 30A, 38AYCP036F-L 56½ 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 20½ 25 1 /8 17 1 /2 10 3 4 7 /16 30A, 38AYCP036F-M 56½ 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 20½ 25 1 /8 17 1 /2 10 3 4 7 /16 30A, 38APHASED OUTYCP036F-H 64 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 20½ 28 1 /2 17 1 /2 10 3 8 3 /4 30A, 38A, 33AYCP042F-M 64 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 20½ 28 1 /2 17 1 /2 10 3 8 3 /4 30A, 38A, 33AYCP048F-H 65 1 /8 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 25 3 /8 30¼ 20 14 3 1 /2 8 15 /16 30A, 38A, 34AYCP060F-M 65 1 /8 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 25 3 /8 28 7 /8 20 14 3 1 /2 8 15 /16 30A, 38A, 34ATable PG-20-B — YCC – XE 1000 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0YCC018F-L 55 1 /4 36 25 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 5 /16 25 17 1 /2 10 3 4 7 /16 30A, 38AYCC024F-L 55 1 /4 36 25 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 5 /16 25 17 1 /2 10 3 4 7 /16 30A, 38AYCC030F-L 55 1 /4 36 25 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 21 5 /16 25 17 1 /2 10 3 4 7 /16 30A, 38AYCC036F-L 55 1 /4 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 20 3 /4 25 13 /16 17 1 /2 10 3 4 7 /16 30A, 38AYCC030F-M 55 1 /4 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 19 3 /4 24 13 /16 17 1 /2 10 3 4 7 /16 30A, 38AYCC036F-M 55 1 /4 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 6 13 /16 17 19 3 /4 24 13 /16 17 1 /2 10 3 4 7 /16 30A, 38APHASED OUTYCC036F-H 62 3 /4 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 19 3 /4 28 1 /4 17 1 /2 10 3 8 3 /4 30A, 38A, 33AYCC042F-M 62 3 /4 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 19 3 /4 28 1 /4 17 1 /2 10 3 8 3 /4 30A, 38A, 33AYCC048F-M 62 3 /4 36 29 3 /16 18 9 /16 11 1 /16 6 9 /16 11 1 /8 17 19 3 /4 28 1 /4 17 1 /2 10 3 8 3 /4 30A, 38A, 33AYCC048F-H 64 5 /16 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 25 29 1 /2 20 14 3 1 /2 8 15 /16 30A, 38A, 34AYCC060F-M 64 5 /16 45 33 3 /8 21 1 /16 15 1 /16 4 15 /16 9 1 /8 21 15 /16 25 29 1 /2 20 14 3 1 /2 8 15 /16 30A, 38A, 34AFor information on Roof Curbs <strong>an</strong>d Roof Curb Adaptors,please refer to the Accessories/Information Tab.Effective 1/1/06PG-20For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Precedent 3-10 tonPackaged Gas ElectricsFeaturingA New Look for a New CenturyBeveled TopSmoother DesignSmall compact cabinetRecessed access h<strong>an</strong>dlesSt<strong>an</strong>dard Features:• <strong>Tr<strong>an</strong>e</strong> built scroll compressors on all 3-10 ton units except 3 ton st<strong>an</strong>dard efficiencymodel (Reciprocating Compressor)• Colored <strong>an</strong>d numbered wiring• Provisions for through the Base Gas <strong>an</strong>d Condensate Drain Connections• Patented Hybrid Condenser Coil for easy cle<strong>an</strong>ing• 1" throwaway filters provided on 3-5 ton units• 2" throwaway filters provided on 6-10 ton units• Liquid Line Refriger<strong>an</strong>t Drier• Operating Charge of R-22• IAQ Sloped Drain P<strong>an</strong>s• Low Ambient to 40°F on Electromech<strong>an</strong>ical models• Low Ambient to 0°F on Microprocessor models• 5 - year Limited Compressor Warr<strong>an</strong>ty• 5 - year Limited Heat Exch<strong>an</strong>ger Warr<strong>an</strong>ty• 1 - year Limited Parts Warr<strong>an</strong>tyAdded Flexibility• Electromech<strong>an</strong>ical or microprocessor controls (See page PC-35 for ReliaTelControl Information)• St<strong>an</strong>dard or high efficiency cooling models available• Low, medium or high heat, single or two stage• Convertible airflow• Fork lift openings on three sides of unit• Direct or belt drive - st<strong>an</strong>dard or oversized motors (Direct for 3-5 ton only)• We don’t prepackage options• Choose options tailored to suit each job —pay only for what is needed• Units ship with options installed —<strong>an</strong>d within our st<strong>an</strong>dard ship cycle timeFactory Installed Options• Through-the-Base — Electrical• Convenience Outlet — Powered or unpowered• Unit Disconnect Switch• Smoke Detectors — Supply, return, or both• Condenser Coil Coating• Hinged Access Service P<strong>an</strong>els• Discharge Air Sensor• F<strong>an</strong> Fail <strong>an</strong>d Clogged Filter Switches• Condenser Coil Guard — Hail Protection Quality• Hot Gas Reheat Coil - Dehumidification• TXV thermal exp<strong>an</strong>sion valve <strong>an</strong>d split face evaporator coil• TCI (<strong>Tr<strong>an</strong>e</strong> Communication Interface)• LonTalk (Communication Interface)• 2" Pleated Media filters• Phase Monitor• FrostatThe same <strong>Tr<strong>an</strong>e</strong> Quality <strong>an</strong>dReliability … with added Flexibility!For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-21 Effective 1/1/06


Precedent Packaged Gas/ElectricConvertible 3-10 TonsTable PG-22-A — Base Unit — St<strong>an</strong>dard Efficiency — Electromech<strong>an</strong>icalHeating Output1 Cabinet ShippingUnit Perform<strong>an</strong>ce3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No.4 SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*YSC – 208-230/1/60 – Single Phase – Low Heat3 YSC036E1ELA0000 13.0 35,620 47,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 27.2 404 YSC048E1ELA0000 13.0 49,210 49,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 35.2 505 YSC060E1ELA0000 13.0 59,900 47,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 43.8 70YSC –208-230/3/60 – Three Phase – Low Heat3 YSC036A3ELA0000 10.7 37,400 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 17.9 254 YSC048A3ELA0000 10.0 49,200 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 23.9 355 YSC060A3ELA0000 10.2 63,100 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 31.5 503 YSC036E3ELA0000 13.0 37,150 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 21.4 304 YSC048E3ELA0000 13.0 49,450 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 25.2 355 YSC060E3ELA0000 13.0 62,270 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 29.5 456 YSC072A3ELA0000 10.2/10.11 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 32.7 507½ YSC090A3ELA0000 10.1 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 42.7 607½ YSC092A3ELA0000 10.4/10.11 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 508½ YSC102A3ELA0000 10.1 105,000 97, 200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 45.1 6010 YSC120A3ELA0000 10.2/10.11 117,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 52.6 60YSC –460/3/60 – Three Phase – Low Heat3 YSC036A4ELA0000 10.7 37,400 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 9.2 154 YSC048A4ELA0000 10.0 49,200 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 12.8 205 YSC060A4ELA0000 10.2 63,100 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 16.0 253 YSC036E4ELA0000 13.0 37,150 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 10.1 154 YSC048E4ELA0000 13.0 49,450 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 12.5 155 YSC060E4ELA0000 13.0 62,270 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 15.5 256 YSC072A4ELA0000 10.2/10.11 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 17.6 257½ YSC090A4ELA0000 10.1 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 22.6 357½ YSC092A4ELA0000 10.4/10.11 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 20.5 258½ YSC102A4ELA0000 10.1 105,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 24.0 3010 YSC120A4ELA0000 10.2/10.11 117,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 26.9 35YSC –575/3/60 – Three Phase – Low Heat3 YSC036AWELA0000 10.7 37,400 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 7.7 154 YSC048AWELA0000 10.0 49,200 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 9.8 155 YSC060AWELA0000 10.2 63,100 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 12.2 153 YSC036EWELA0000 13.0 37,150 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 8.0 154 YSC048EWELA0000 13.0 49,450 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 9.0 155 YSC060EWELA0000 13.0 62,270 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 10.1 156 YSC072AWELA0000 10.2/10.11 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 12.8 207½ YSC090AWELA0000 10.1 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 17.6 257½ YSC092AWELA0000 10.4/10.11 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 15.5 208½ YSC102AWELA0000 10.1 105,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 19.5 2510 YSC120AWELA0000 10.2/10.11 117,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 21.8 257½ YSC092A3EMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 508½ YSC102A3EMA0000 10.1 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 44.4 6010 YSC120A3EMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 50.9 60* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.4 Digit 7 - A=R-22, E=410A.Effective 1/1/06PG-22For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Precedent Packaged Gas/ElectricConvertible 3-10 TonsTable PG-23-A — Base Unit — St<strong>an</strong>dard Efficiency — Electromech<strong>an</strong>icalHeating Output1 Cabinet ShippingUnit Perform<strong>an</strong>ce3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No.4 SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*YSC – 208-230/1/60 – Single Phase – Medium Heat3 YSC036E1EMA0000 13.0 35,620 65,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 27.2 404 YSC048E1EMA0000 13.0 49,210 65,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 35.2 505 YSC060E1EMA0000 13.0 59,900 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 43.8 70YSC –208-230/3/60 – Three Phase – Medium Heat3 YSC036A3EMA0000 10.7 37,400 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 17.9 254 YSC048A3EMA0000 10.0 49,200 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 23.9 355 YSC060A3EMA0000 10.2 63,100 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 31.5 503 YSC036E3EMA0000 13.0 37,150 64,000 81 32 x 44 x 70 18 x 15.5 12 x 14 607 21.4 304 YSC048E3EMA0000 13.0 49,450 64,000 81 32 x 44 x 70 18 x 15.5 12 x 14 638 25.2 355 YSC060E3EMA0000 13.0 62,270 64,000 81 32 x 44 x 70 18 x 15.5 12 x 14 688 29.5 456 YSC072A3EMA0000 10.2/10.11 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 32.2 507½ YSC090A3EMA0000 10.1 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 42.7 607½ YSC092A3EMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 508½ YSC102A3EMA0000 10.1 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 44.4 6010 YSC120A3EMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 50.9 60YSC –460/3/60 – Three Phase – Medium Heat3 YSC036A4EMA0000 10.7 37,400 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 9.2 154 YSC048A4EMA0000 10.0 49,200 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 12.8 205 YSC060A4EMA0000 10.2 63,100 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 16.0 253 YSC036E4EMA0000 13.0 37,150 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 10.1 154 YSC048E4EMA0000 13.0 49,450 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 12.5 155 YSC060E4EMA0000 13.0 62,270 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 15.5 256 YSC072A4EMA0000 10.2/10.11 63,100 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 17.6 257½ YSC090A4EMA0000 10.1 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 22.6 357½ YSC092A4EMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 20.5 258½ YSC102A4EMA0000 10.11 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 24.0 3010 YSC120A4EMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 26.9 35YSC –575/3/60 – Three Phase – Medium Heat3 YSC036AWEMA0000 10.7 37,400 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 7.7 154 YSC048AWEMA0000 10.0 49,200 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 9.8 155 YSC060AWEMA0000 10.2 63,100 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 12.2 153 YSC036EWEMA0000 13.0 37,150 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 8.0 154 YSC048EWEMA0000 13.0 49,450 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 9.0 155 YSC060EWEMA0000 13.0 62,270 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 10.1 156 YSC072AWEMA0000 10.2/10.11 63,100 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 12.8 207½ YSC090AWEMA0000 10.1 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 17.6 257½ YSC092AWEMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 15.5 208½ YSC102AWEMA0000 10.1 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 19.5 2510 YSC120AWEMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 21.8 25* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.4 Digit 7 - A=R-22, E=410A.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-23 Effective 1/1/06


Precedent Packaged Gas/ElectricConvertible 3-10 TonsTable PG-24-A — Base Unit — St<strong>an</strong>dard Efficiency — Electromech<strong>an</strong>icalHeating Output1 Cabinet ShippingUnit Perform<strong>an</strong>ce3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No.4 SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*YSC –208-230/1/60 – Single Phase – High Heat3 YSC036E1EHA0000 13.0 35,620 94,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 27.2 404 YSC048E1EHA0000 13.0 49,210 95,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 35.2 505 YSC060E1EHA0000 13.0 59,900 103,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 43.8 70YSC –208-230/3/60 – Three Phase – High Heat3 YSC036A3EHA0000 10.7 37,400 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 572 17.9 254 YSC048A3EHA0000 10.0 49,200 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 597 23.9 355 YSC060A3EHA0000 10.2 63,100 104,000 81 36 x 44 x 70 18 x 15.5 24 x 14 614 31.5 503 YSC036E3EHA0000 13.0 37,150 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 21.4 304 YSC048E3EHA0000 13.0 49,450 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 25.2 355 YSC060E3EHA0000 13.0 62,270 104,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 29.5 456 YSC072A3EHA0000 10.1 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 32.7 507½ YSC090A3EHA0000 10.1 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 42.7 607½ YSC092A3EHA0000 10.4/10.11 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 508½ YSC102A3EHA0000 10.11 105,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 45.1 6010 YSC120A3EHA0000 10.2/10.11 117,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 52.6 60YSC –460/3/60 – Three Phase – High Heat3 YSC036A4EHA0000 10.7 37,400 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 572 9.2 154 YSC048A4EHA0000 10.0 49,200 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 597 12.8 205 YSC060A4EHA0000 10.2 63,100 104,000 81 36 x 44 x 70 18 x 15.5 24 x 14 614 16.0 253 YSC036E4EHA0000 13.0 37,150 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 10.1 154 YSC048E4EHA0000 13.0 49,450 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 12.5 155 YSC060E4EHA0000 13.0 62,270 104,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 15.5 256 YSC072A4EHA0000 10.1 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 17.6 257½ YSC090A4EHA0000 10.1 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 22.6 357½ YSC092A4EHA0000 10.4/10.11 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 20.5 258½ YSC102A4EHA0000 10.1 105,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 24.0 3010 YSC120A4EHA0000 10.2/10.11 117,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 26.9 35YSC –575/3/60 – Three Phase – High Heat3 YSC036AWEHA0000 10.7 37,400 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 572 7.7 154 YSC048AWEHA0000 10.0 49,200 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 597 9.8 155 YSC060AWEHA0000 10.2 63,100 104,000 81 36 x 44 x 70 18 x 15.5 24 x 14 614 12.2 153 YSC036EWEHA0000 13.0 37,150 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 8.0 154 YSC048EWEHA0000 13.0 49,450 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 9.0 155 YSC060EWEHA0000 13.0 2,270 104,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 10.1 156 YSC072AWEHA0000 10.2/10.11 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 12.8 207½ YSC090AWEHA0000 10.1 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 17.6 257½ YSC092AWEHA0000 10.4/10.11 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 15.5 208½ YSC102AWEHA0000 /10.1 105,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 19.5 2510 YSC120AWEHA0000 10.2/10.11 117,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 21.8 25* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.4 Digit 7 - A=R-22, E=410A.Effective 1/1/06PG-24For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Precedent Packaged Gas/ElectricConvertible 3-10 TonsTable PG-25-A — Base Unit — St<strong>an</strong>dard Efficiency — ReliaTel Microprocessor ControlsHeating Output1 Cabinet ShippingUnit Perform<strong>an</strong>ce3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No.4 SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*YSC – 208-230/1/60 – Single Phase – Low Heat3 YSC036E1RLA0000 13.0 35,620 47,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 27.2 404 YSC048E1RLA0000 13.0 49,210 47,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 35.2 505 YSC060E1RLA0000 13.0 59,900 47,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 43.8 70YSC –208-230/3/60 – Three Phase – Low Heat3 YSC036A3RLA0000 10.7 37,400 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 17.9 254 YSC048A3RLA0000 10.0 49,200 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 23.9 355 YSC060A3RLA0000 10.2 63,100 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 31.5 503 YSC036E3RLA0000 13.0 37,150 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 21.4 304 YSC048E3RLA0000 13.0 49,450 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 25.2 355 YSC060E3RLA0000 13.0 62,270 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 29.5 456 YSC072A3RLA0000 10.2/10.11 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 32.7 507½ YSC090A3RLA0000 10.1 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 42.7 607½ YSC092A3RLA0000 10.4/10.11 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 508½ YSC102A3RLA0000 10.1 105,000 97, 200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 45.1 6010 YSC120A3RLA0000 10.2/10.11 117,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 52.6 60YSC –460/3/60 – Three Phase – Low Heat3 YSC036A4RLA0000 10.7 37,400 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 9.2 154 YSC048A4RLA0000 10.0 49,200 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 12.8 205 YSC060A4RLA0000 10.2 63,100 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 16.0 253 YSC036E4RLA0000 13.0 37,150 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 10.1 154 YSC048E4RLA0000 13.0 49,450 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 12.5 155 YSC060E4RLA0000 13.0 62,270 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 15.5 256 YSC072A4RLA0000 10.2/10.11 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 17.6 257½ YSC090A4RLA0000 10.1 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 22.6 357½ YSC092A4RLA0000 10.4/10.11 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 20.5 258½ YSC102A4RLA0000 10.1 105,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 24.0 3010 YSC120A4RLA0000 10.2/10.11 117,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 26.9 35YSC –575/3/60 – Three Phase – Low Heat3 YSC036AWRLA0000 10.7 37,400 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 7.7 154 YSC048AWRLA0000 10.0 49,200 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 9.8 155 YSC060AWRLA0000 10.2 63,100 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 12.2 153 YSC036EWRLA0000 13.0 37,150 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 8.0 154 YSC048EWRLA0000 13.0 49,450 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 9.0 155 YSC060EWRLA0000 13.0 62,270 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 10.1 156 YSC072AWRLA0000 10.2/10.11 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 12.8 207½ YSC090AWRLA0000 10.1 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 17.6 257½ YSC092AWRLA0000 10.4/10.11 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 15.5 208½ YSC102AWRLA0000 10.1 105,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 19.5 2510 YSC120AWRLA0000 10.2/10.11 117,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 21.8 25* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.4 Digit 7 - A=R-22, E=410A..For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-25 Effective 1/1/06


Precedent Packaged Gas/ElectricConvertible 3-10 TonsTable PG-26-A — Base Unit — St<strong>an</strong>dard Efficiency — ReliaTel Microprocessor ControlsHeating Output1 Cabinet ShippingUnit Perform<strong>an</strong>ce3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No.4 SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*YSC – 208-230/1/60 – Single Phase – Medium Heat3 YSC036E1RMA0000 13.0 35,620 65,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 27.2 404 YSC048E1RMA0000 13.0 49,210 65,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 35.2 505 YSC060E1RMA0000 13.0 59,900 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 43.8 70YSC –208-230/3/60 – Three Phase – Medium Heat3 YSC036A3RMA0000 10.7 37,400 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 17.9 254 YSC048A3RMA0000 10.0 49,200 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 23.9 355 YSC060A3RMA0000 10.2 63,100 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 31.5 503 YSC036E3RMA0000 13.0 37,150 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 21.4 304 YSC048E3RMA0000 13.0 49,450 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 25.2 355 YSC060e3RMA0000 13.0 62,270 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 29.5 456 YSC072A3RMA0000 10.2/10.11 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 32.7 507½ YSC090A3RMA0000 10.1 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 42.7 607½ YSC092A3RMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 508½ YSC102A3RMA0000 10.1 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 45.1 6010 YSC120A3RMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 52.6 60YSC –460/3/60 – Three Phase – Medium Heat3 YSC036A4RMA0000 10.7 37,400 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 9.2 154 YSC048A4RMA0000 10.0 49,200 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 12.8 205 YSC060A4RMA0000 10.2 63,100 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 16.0 253 YSC036E4RMA0000 13.0 37,150 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 10.1 154 YSC048E4RMA0000 13.0 49,450 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 12.5 155 YSC060E4RMA0000 13.0 62,270 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 15.5 256 YSC072A4RMA0000 10.2/10.11 63,100 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 17.6 257½ YSC090A4RMA0000 10.1 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 22.6 357½ YSC092A4RMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 20.5 258½ YSC102A4RMA0000 10.1 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 24.0 3010 YSC120A4RMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 26.9 35YSC –575/3/60 – Three Phase – Medium Heat3 YSC036AWRMA0000 10.7 37,400 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 7.7 154 YSC048AWRMA0000 10.0 49,200 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 9.8 155 YSC060AWRMA0000 10.2 63,100 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 12.2 153 YSC036EWRMA0000 13.0 37,150 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 8.0 154 YSC048EWRMA0000 13.0 49,450 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 9.0 155 YSC060EWRMA0000 13.0 62,270 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 10.1 156 YSC072AWRMA0000 10.1 63,100 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 12.8 207½ YSC090AWRMA0000 10.1 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 17.6 257½ YSC092AWRMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 15.5 208½ YSC102AWRMA0000 10.2 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 19.5 2510 YSC120AWRMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 21.8 25* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.4 Digit 7 - A=R-22, E=410A.Effective 1/1/06PG-26For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Precedent Packaged Gas/ElectricConvertible 3-10 TonsTable PG-27-A — Base Unit — St<strong>an</strong>dard Efficiency — ReliaTel Microprocessor ControlsHeating Output1 Cabinet ShippingUnit Perform<strong>an</strong>ce3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No.4 SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*YSC –208-230/1/60 – Single Phase – High Heat3 YSC036E1RHA0000 13.0 35,620 94,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 27.2 404 YSC048E1RHA0000 13.0 49,210 95,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 35.2 505 YSC060E1RHA0000 13.0 59,900 103,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 43.8 70YSC –208-230/3/60 – Three Phase – High Heat3 YSC036A3RHA0000 10.7 37,400 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 572 17.9 254 YSC048A3RHA0000 10.0 49,200 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 597 23.9 355 YSC060A3RHA0000 10.2 63,100 104,000 81 36 x 44 x 70 18 x 15.5 24 x 14 614 31.5 503 YSC036E3RHA0000 13.0 37,150 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 21.4 304 YSC048E3RHA0000 13.0 49,450 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 25.2 355 YSC060E3RHA0000 13.0 62,270 104,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 29.5 456 YSC072A3RHA0000 10.2/10.11 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 32.7 507½ YSC090A3RHA0000 10.1 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 42.7 607½ YSC092A3RHA0000 10.4/10.11 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 508½ YSC102A3RHA0000 10.1 105,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 45.1 6010 YSC120A3RHA0000 10.2/10.11 117,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 52.6 60YSC –460/3/60 – Three Phase – High Heat3 YSC036A4RHA0000 10.7 37,400 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 572 9.2 154 YSC048A4RHA0000 10.0 49,200 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 597 12.8 205 YSC060A4RHA0000 10.2 63,100 104,000 81 36 x 44 x 70 18 x 15.5 24 x 14 614 16.0 253 YSC036E4RHA0000 13.0 37,150 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 10.1 154 YSC048E4RHA0000 13.0 49,450 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 12.5 155 YSC060E4RHA0000 13.0 62,270 104,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 15.5 256 YSC072A4RHA0000 10.2/10.11 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 17.6 257½ YSC090A4RHA0000 10.1 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 22.6 357½ YSC092A4RHA0000 10.4/10.11 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 20.5 258½ YSC102A4RHA0000 10.1 105,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 24.0 3010 YSC120A4RHA0000 10.2/10.11 117,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 26.9 35YSC –575/3/60 – Three Phase – High Heat3 YSC036AWRHA0000 10.7 37,400 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 572 7.7 154 YSC048AWRHA0000 10.0 49,200 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 597 9.8 155 YSC060AWRHA0000 10.2 63,100 104,000 81 36 x 44 x 70 18 x 15.5 24 x 14 614 12.2 153 YSC036EWRHA0000 13.0 37,150 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 8.0 154 YSC048EWRHA0000 13.0 49,450 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 9.0 155 YSC060EWRHA0000 13.0 62,270 104,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 10.1 156 YSC072AWRHA0000 10.2/10.11 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 12.8 207½ YSC090AWRHA0000 10.1 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 17.6 257½ YSC092AWRHA0000 10.4/10.11 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 15.5 208½ YSC102AWRHA0000 10.1 105,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 19.5 2510 YSC120AWRHA0000 10.2/10.11 117,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 11300 21.8 25* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.4 Digit 7 - A=R-22, E=410A.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-27 Effective 1/1/06


Precedent Packaged Gas/ElectricConvertible 3-10 TonsTable PG-28-A — Base Unit — High Efficiency — Electromech<strong>an</strong>icalHeating Output1 Cabinet ShippingUnit Perform<strong>an</strong>ce3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No. SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*YHC –208-230/3/60 – Three Phase – Low Heat6 YHC072A3ELA0000 11.5/11.31 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 34.8 507½ YHC092A3ELA0000 11.5/11.31 90,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 38.1 508½ YHC102A3ELA0000 11.5/11.31 102,000 97, 200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 42.3 5010 YHC120A3ELA0000 11.2/10.71 116,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 48.6 60YHC –460/3/60 – Three Phase – Low Heat6 YHC072A4ELA0000 11.5/11.31 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 17.5 257½ YHC092A4ELA0000 11.5/11.31 90,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 19.4 258½ YHC102A4ELA0000 11.5/11.31 102,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 21.4 2510 YHC120A4ELA0000 11.2/10.71 116,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 25.3 30YHC –575/3/60 – Three Phase – Low Heat6 YHC072AWELA0000 11.5/11.31 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 13.5 207½ YHC092AWELA0000 11.5/11.31 90,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 14.8 158½ YHC102AWELA0000 11.5/11.31 102,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 16.6 2010 YHC120AWELA0000 11.2/10.71 116,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 19.9 25YHC –208-230/3/60 – Three Phase – Medium Heat6 YHC072A3EMA0000 11.5/11.31 72,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 915 34.8 507½ YHC092A3EMA0000 11.5/11.31 90,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 38.1 508½ YHC102A3EMA0000 11.5/11.31 102,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 42.3 5010 YHC120A3EMA0000 11.2/10.71 116,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 48.6 60YHC –460/3/60 – Three Phase – Medium Heat6 YHC072A4EMA0000 11.4/11.01 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 17.5 257½ YHC092A4EMA0000 11.4/11.01 90,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 19.4 258½ YHC102A4EMA0000 11.4/11.01 102,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 21.4 2510 YHC120A4EMA0000 11.3/10.81 116,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 25.3 30YHC –575/3/60 – Three Phase – Medium Heat6 YHC072AWEMA0000 11.4/11.01 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 13.5 207½ YHC092AWEMA0000 11.4/11.01 90,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 14.8 158½ YHC102AWEMA0000 11.4/11.01 102,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 16.6 2010 YHC120AWEMA0000 11.3/10.81 116,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 19.9 25YHC –208-230/3/60 – Three Phase – High Heat6 YHC072A3EHA0000 11.4/11.01 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 34.8 507½ YHC092A3EHA0000 11.4/11.01 90,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 38.1 508½ YHC102A3EHA0000 11.4/11.01 102,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 42.3 5010 YHC120A3EHA0000 11.3/10.81 116,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 48.6 60YHC –460/3/60 – Three Phase – High Heat6 YHC072A4EHA0000 11.4/11.01 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 17.5 257½ YHC092A4EHA0000 11.4/11.01 90,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 19.4 258½ YHC102A4EHA0000 11.4/11.01 102,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 21.4 2510 YHC120A4EHA0000 11.3/10.81 116,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 25.3 30YHC –575/3/60 – Three Phase – High Heat6 YHC072AWEHA0000 11.4/11.01 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 13.5 207½ YHC092AWEHA0000 11.4/11.01 90,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 14.8 158½ YHC102AWEHA0000 11.4/11.01 102,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 16.6 2010 YHC120AWEHA0000 11.3/10.81 116,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 19.9 25* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.Effective 1/1/06PG-28For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Precedent Packaged Gas/ElectricConvertible 3-10 TonsTable PG-29-A — Base Unit — High Efficiency — ReliaTel Microprocessor ControlsHeating Output1 Cabinet ShippingUnit Perform<strong>an</strong>ce3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No. SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*YHC –208-230/3/60 – Three Phase – Low Heat6 YHC072A3RLA0000 11.4/11.01 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 34.8 507½ YHC092A3RLA0000 11.4/11.01 90,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 38.1 508½ YHC102A3RLA0000 11.4/11.01 102,000 97, 200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 42.3 5010 YHC120A3RLA0000 11.3/10.81 116,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 48.6 60YHC –460/3/60 – Three Phase – Low Heat6 YHC072A4RLA0000 11.4/11.01 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 17.5 257½ YHC092A4RLA0000 11.4/11.01 90,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 19.4 258½ YHC102A4RLA0000 11.4/11.01 102,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 21.4 2510 YHC120A4RLA0000 11.3/10.81 116,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 25.3 30YHC –575/3/60 – Three Phase – Low Heat6 YHC072AWRLA0000 11.4/11.01 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 13.5 207½ YHC092AWRLA0000 11.4/11.01 90,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 14.8 158½ YHC102AWRLA0000 11.4/11.01 105,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 16.6 2010 YHC120AWRLA0000 11.3/10.81 116,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 19.9 25YHC –208-230/3/60 – Three Phase – Medium Heat6 YHC072A3RMA0000 11.4/11.01 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 34.8 507½ YHC092A3RMA0000 11.4/11.01 90,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 38.1 508½ YHC102A3RMA0000 11.4/11.01 102,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 42.3 5010 YHC120A3RMA0000 11.3/10.81 116,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 48.6 60YHC –460/3/60 – Three Phase – Medium Heat6 YHC072A4RMA0000 11.4/11.01 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 17.5 257½ YHC092A4RMA0000 11.4/11.01 90,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 19.4 258½ YHC102A4RMA0000 11.4/11.01 102,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 21.4 2510 YHC120A4RMA0000 11.3/10.81 116,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 25.3 30YHC –575/3/60 – Three Phase – Medium Heat6 YHC072AWRMA0000 11.4/11.01 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 13.5 207½ YHC092AWRMA0000 11.4/11.01 90,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 14.8 158½ YHC102AWRMA0000 11.4/11.01 102,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 16.6 2010 YHC120AWRMA0000 11.3/10.81 116,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 19.9 25YHC –208-230/3/60 – Three Phase – High Heat6 YHC072A3RHA0000 11.4/11.01 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 34.8 507½ YHC092A3RHA0000 11.4/11.01 90,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 38.1 508½ YHC102A3RHA0000 11.4/11.01 102,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 42.3 5010 YHC120A3RHA0000 11.3/10.81 116,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 48.6 60YHC –460/3/60 – Three Phase – High Heat6 YHC072A4RHA0000 11.4/11.01 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 17.5 257½ YHC092A4RHA0000 11.4/11.01 90,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 19.4 258½ YHC102A4RHA0000 11.4/11.01 102,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 21.4 2510 YHC120A4RHA0000 11.3/10.81 116,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 25.3 30YHC –575/3/60 – Three Phase – High Heat6 YHC072AWRHA0000 11.4/11.01 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 13.5 207½ YHC092AWRHA0000 11.4/11.01 90,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 14.8 158½ YHC102AWRHA0000 11.4/11.01 102,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 16.6 2010 YHC120AWRHA0000 11.3/10.81 116,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 19.9 25* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-29 Effective 1/1/06


Precedent Packaged Gas/ElectricConvertible 3-10 Tons(Model Digit Numbers)Digit Description Order Number1-8 Main Assembly (see previous page)9 Unit ControlsElectromech<strong>an</strong>ical .................................................... EUnit Controls -ReliaTel Micro-processor .................. R10 Heating CapacityLow ......................................................................... LMedium .................................................................. MHigh ......................................................................... HLow - Stainless Steel Heat Exch<strong>an</strong>ger ....................... XMedium - Stainless Steel Heat Exch<strong>an</strong>ger .................. YHigh - Stainless Steel Heat Exch<strong>an</strong>ger ....................... Z11 Minor Design SequenceFirst Sequence ........................................................ A12-13 Service SequenceFirst Sequence (Factory assigned) .......................... ✱,✱14 Fresh Air SelectionNo Fresh Air ............................................................. 00-50% M<strong>an</strong>ual Outside Air Dampere ......................... A0-50% Motorized Outside Air Damper ........................ B0-100% Economizer, Dry Bulb withoutBarometric Relief2 ................................................ C0-100% Economizer, Dry Bulb withBarometric Relief2 ............................................... D0-100% Economizer, Reference Enthalpywithout Barometric Relief12 .................................. E0-100%Economizer, Reference Enthalpywith Barometric Relief12 ....................................... F0-100%Economizer, Comparative Enthalpywithout Barometric Relief 12 ................................ G0-100%Economizer, Comparative Enthalpywith Barometric Relief 12 ...................................... H15 Supply F<strong>an</strong>/Drive Type/MotorSt<strong>an</strong>dard Drive ......................................................... 0Oversized Motor ....................................................... 1Optional Belt Drive Motor (3 phase only) .................... 216 Hinged Service Access & FiltersSt<strong>an</strong>dard P<strong>an</strong>els & Filters ......................................... 0Hinged Access P<strong>an</strong>els & St<strong>an</strong>dard Filters .................. ASt<strong>an</strong>dard p<strong>an</strong>els & 2" Pleated Filters .......................... BHinged Access P<strong>an</strong>els & 2" Pleated Filters ................ C17 Condenser Coil ProtectionSt<strong>an</strong>dard Coil ........................................................... 0St<strong>an</strong>dard Coil with Hail Guard ................................... 1Epoxy Coated Condenser Coil .................................. 2Epoxy Coated Condenser Coil with Hail Guard .......... 318 Through the Base ProvisionsNo Through the Base Provisions ............................... 0Through the Base Electrict ...................................... AThrough the Base Gas .............................................. BThrough the Base Gas <strong>an</strong>d Electricw ......................... C1 Enthalpy control not available factory installed with electro-mech<strong>an</strong>ical controls.2 Economizer with Barometric Relief is for downfllow configured units only. OrderEconomizer without Barometric Relief for horizontal configuration. Barometric relief forhorizontal configured units must be ordered as field installed accessory BAYBARM010A.3 Requires use of Disconnect or Circuit Breaker.4 St<strong>an</strong>dard refrigeration metering device - short orifice.5 Frostat c<strong>an</strong>not be field installed in electro-mech<strong>an</strong>ical units.6 High Pressure control is st<strong>an</strong>dard on 3 phase units with scroll compressors <strong>an</strong>d inYSC036A.7 Not available with BAYFRST001A High Temperature Stat accessory.7 The return air smoke detector may not fit up or work properly on the Precedent unitswhen used in conjunction with 3rd party accessories such as bolt on heat wheels,economizers <strong>an</strong>d power exhaust. Do not order the return air smoke detectors whenusing this type of accessory.Digit Description Order Number19 Disconnect/Circuit Breaker/Phase Monitor (3 phase only)No Disconnect Circuit Breaker/No Phase Monitor ....... 0Non-Fused Disconnectt ........................................... 1Circuit Breakert ....................................................... 2Phase Monitory ....................................................... 3Phase Monitory & Non-Fused Disconnect Switch ...... 4Phase Monitory & Circuit Breaker ............................. 520 Convenience OutletNo Convenience Outlet ............................................. 0Unpowered Convenience Outlet ............................... APowered Convenience Outlet (3 phase only)3 ........... B21 Communications OptionsuNo Communications Interface ................................... 0<strong>Tr<strong>an</strong>e</strong> Communications Interface ............................... 1LonTalk ® Communications Interface .......................... 2Novar 2024 Controls ................................................. 3Novar 3051 Controls ................................................. 422 Refrigeration System OptionSt<strong>an</strong>dard Refrigeration System4 ............................... 0Thermal Exp<strong>an</strong>sion Value (TXV)4 ............................. ADehumidification (Hot Gas Reheat Coil)r .................. B23 Refrigeration ControlsNo Refrigeration Control ........................................... 0High Pressure Control6u ......................................... 1Frostat5 .................................................................. 2Cr<strong>an</strong>kcase Heater .................................................... 3High Pressure Control6u <strong>an</strong>d Frostat5 ..................... 4High Pressure Control6u <strong>an</strong>d Cr<strong>an</strong>kcase Heater ....... 5Frostat5 <strong>an</strong>d Cr<strong>an</strong>kcase Heater6 ............................. 6High Pressure Control6u, Frostat5 <strong>an</strong>dCr<strong>an</strong>kcase Heater6 .............................................. 724 Smoke Detector7uNo Smoke Detector .................................................. 0Return Air Smoke Detector89 .................................. ASupply Air Smoke Detector ....................................... BSupply <strong>an</strong>d Return Air Smoke Detectors89 ............... C25 Monitoring ControlsuNo Monitoring Control0 ............................................ 0Clogged Filter Switch0 ............................................. 1F<strong>an</strong> Failure Switch0 ................................................. 2Discharge Air Sensing Tube0 ................................... 3Clogged Filter Switch <strong>an</strong>d F<strong>an</strong> Fail Switch0 ............... 4Clogged Filter Switch <strong>an</strong>d DischargeAir Sensing Tube0 ................................................ 5F<strong>an</strong> Fail Switch <strong>an</strong>d Discharge Air Sensing Tube0 ..... 6Clogged Filter <strong>an</strong>d F<strong>an</strong> Fail Switches<strong>an</strong>d Discharge Air Sensing Tube0 .......................... 7Novar Return Air Sensorq ........................................ 89 Return Air Smoke Detector c<strong>an</strong>not be ordered with Novar Controls.0 These options are st<strong>an</strong>dard when ordering Novar Controls.q This option is used when ordering Novar Controls.w Includes gas piping <strong>an</strong>d shutoff (field assembly required).e The m<strong>an</strong>ual outside air damper will ship factory supplied within the unit, but must be fieldinstalled.r Requires Selection of 2" Pleated Filters (Option B or C) for Digit 16.t Through the base electric required when ordering disconnect/circuit breaker options.y Phase Monitor is st<strong>an</strong>dard on T/Y/WSC060A3,4,W models. All other models phasemonitor will be <strong>an</strong> option.u Not available with electro-mech<strong>an</strong>ical controls.Effective 1/1/06PG-30For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Precedent Packaged Gas/ElectricConvertible 3-10 TonsTable PG-31-A — AccessoriesModel Number Description Used WithyBAYABRD001C5 .................... ReliaTel Options Module ...................................................... See Note8BAYASCT0010e .................... Anti-Short-Cycle Timer ............................................................ Y*C036-060(A or E), Y*C072-120A_EBAYBARM011A7 .................... Barometric Relief ..................................................................... Y*C072-120ABAYBARM010A7 .................... Barometric Relief ..................................................................... Y*C036-060(A or E)BAYCCHT010B ........................ Cr<strong>an</strong>kcase Heater ................................................................... YSC048-060(A or E), YSC072A1,A3, Y*C092-120A3, YHC072A1,A3BAYCCHT011B ........................ Cr<strong>an</strong>kcase Heater ................................................................... YSC048-060(A or E), YSC072A4,AW, Y*C092-120A4,AW, YHC072A4,AWBAYCCHT012A ....................... Cr<strong>an</strong>kcase Heater ................................................................... Y*C090A3BAYCCHT013A ....................... Cr<strong>an</strong>kcase Heater ................................................................... Y*C090A4BAYCCHT014A ....................... Cr<strong>an</strong>kcase Heater ................................................................... Y*C090AWBAYCO2K001B5r ................ CO 2 Sensor Kit, Wall Mounted ................................................ Y*C036-060(A or E), Y*C072-120A_RBAYCO2K003B5r ................ CO 2 Sensor Kit, Duct Mounted ................................................ Y*C036-060(A or E), Y*C072-120A_RBAYCURB042A4 .................... Roof Curb ................................................................................ Y*C036-060(A or E)BAYCURB043A4 .................... Roof Curb ................................................................................ Y*C072-120ABAYDFPS003A58 ................. Clogged Filter Switch .............................................................. Y*C036-060(A or E), Y*C072-120A_RBAYDFPS004A58 ................. F<strong>an</strong> Failure Switch ................................................................... Y*C036-060(A or E), Y*C072-120A_RBAYDMPR051A5 ................... 0-50% Motorized Outside Air Damper .................................... Y*C036-060(A or E)BAYDMPR052A0 ................... 0-50% Motorized Outside Air Damper .................................... Y*C036-060(A or E)_EBAYDMPR053Bt ................... 0-50% M<strong>an</strong>ual Outside Air Damper ........................................ Y*C036-060(A or E)BAYDMPR054A5 ................... 0-50% Motorized Outside Air Damper .................................... Y*C072-120A_RBAYDMPR055A0 ................... 0-50% Motorized Outside Air Damper .................................... Y*C072-120A_EBAYDMPR056Bt ................... 0-50% M<strong>an</strong>ual Outside Air Damper ........................................ Y*C072-120ABAYECON085A5 .................... 0-100% Dry Bulb Economizer without Barometric Relief ........ Y*C036-060(A or E)_RBAYECON086A0 .................... 0-100% Dry Bulb Economizer without Barometric Relief ........ Y*C036-060(A or E)_EBAYECON087A5 ................... 0-100% Dry Bulb Economizer without Barometric Relief ........ Y*C072-120A_RBAYECON088A0 ................... 0-100% Dry Bulb Economizer without Barometric Relief ........ Y*C072-120A_EBAYENTH005A1 .................... Reference Enthalpy Kit ............................................................ BAYECON085A, 087ABAYENTH006A1 .................... Comparative Enthalpy Kit ........................................................ BAYECON085A, 087ABAYENTH001A ........................ Enthalpy Control (Solid State .................................................. BAYECON086A, 088ABAYFRST001A56 ................. High Temperature Stat ............................................................. Y*C036-060(A or E), Y*072-120A_EBAYGARD036B ....................... Condenser Coil Hail Guard ..................................................... YSC036-060(A or E)**L,M, YHC036-048(A or E)**L,MBAYGARD037B ....................... Condenser Coil Hail Guard ..................................................... YSC036-060(A or E)**H, YHC036-048(A or E)**H,YHC060(A or E)**L,M,HBAYGARD040B ....................... Condenser Coil Hail Guard ..................................................... YSC072A,090A,092A,YHC072ABAYGARD041B ....................... Condenser Coil Hail Guard ..................................................... YSC102A,120A,YHC092,102A,120ABAYHAKT010B ........................ High Altitude Kit ....................................................................... Y*C036-060(A or E), Y*C072-120ABAYHSDR012A ....................... High Static Drive Kit ................................................................ Y*C072A,YSC090, 092ABAYHSMT073A ....................... .45 HP Oversized motor kit ..................................................... Y*C036(A or E)1,(A or E)3BAYHSMT074A ....................... .45 HP Oversized motor kit ..................................................... Y*C036(A or E)4BAYHSMT075A ....................... .45 HP Oversized motor kit ..................................................... Y*C036(A or E)WBAYHSMT076A ....................... .75 HP Oversized motor kit ..................................................... Y*C048(A or E)1,(A or E)3BAYHSMT077A ....................... .75 HP Oversized motor kit ..................................................... Y*C048(A or E)4BAYHSMT078A ....................... .75 HP Oversized motor kit ..................................................... Y*C048(A or E)WBAYHSMT079A ....................... 1.2 HP Oversized motor kit ..................................................... Y*C060(A or E)1,(A or E)3BAYHSMT080A ....................... 1.2 HP Oversized motor kit ..................................................... Y*C060(A or E)4BAYHSMT081A ....................... 1.2 HP Oversized motor kit ..................................................... Y*C060(A or E)WBAYHSMT082A ....................... 2 HP Oversized motor kit ........................................................ Y*C072A3,A4BAYHSMT083A ....................... 2 HP Oversized motor kit ........................................................ Y*C072AWBAYHSMT084A ....................... 3 HP Oversized motor kit ........................................................ YSC090,092A3, A4BAYHSMT085A ....................... 3 HP Oversized motor kit ........................................................ YSC090,092AWBAYHSMT086A ....................... 3 HP Oversized motor kit ........................................................ Y*C102A3,A4,YHC092A3, A4BAYHSMT087A ....................... 3 HP Oversized motor kit ........................................................ Y*C102AW,YHC092AWBAYHSMT088A ....................... 5 HP Oversized motor kit ........................................................ Y*C120A3,A4BAYHSMT089A ....................... 5 HP Oversized motor kit ........................................................ Y*C120AWBAYICSI003A5q .................... <strong>Tr<strong>an</strong>e</strong> Communications Interface (TCI) ................................... Y*C036-060(A or E), Y*C072-120A_RBAYKSKT255A ........................ Quick Start Kit ......................................................................... YSC048-060(A or E)1BAYKSKT256A ........................ Quick Start Kit ......................................................................... YSC036(A or E)1BAYLOAM020B28 ................ Evaporator Defrost Control (Frostat) ....................................... Y*C036-060(A or E)_RBAYLPKT028B ........................ LP Conversion Kit .................................................................... Y*C036-060(A or E), Y*C072L,M,Y*C090L,092L,Y*C102LBAYLPKT029A ........................ LP Conversion Kit .................................................................... Y*C072A**H, Y*C090,092,102A**M,H,Y*C120A**L,M,HBAYLTCI002B5 ....................... LonTalk ® Communications Interface (LCI) .............................. Y*C036-060(A or E), Y*C072-120A_RBAYPWRX026Aw ................... Power Exhaust ........................................................................ Y*C072-120A3BAYPWRX027Aw ................... Power Exhaust ........................................................................ Y*C072-120A4BAYPWRX028Aw ................... Power Exhaust ........................................................................ Y*C072-120AWBAYQACB009A49 ................ Quick Adapt Curb .................................................................... Y*C036-060(A or E)BAYQACB010A49 ................ Quick Adapt Curb .................................................................... Y*C036-060(A or E)BAYQACB011A49 ................ Quick Adapt Curb .................................................................... Y*C072-120ABAYQACB012A49 ................ Quick Adapt Curb .................................................................... Y*C072-120ABAYQACB013A49 ................ Quick Adapt Curb .................................................................... Y*C072-120ABAYSENS016A5 .................... Temperature Sensor ................................................................ Y*C036-060(A or E), Y*C072-120A_RBAYSERV001A5 .................... Selective Resist<strong>an</strong>ce Service Tester ....................................... Y*C036-060(A or E)_RBAYSTAT0235 ........................ Remote Potentiometer ............................................................. BAYECON085ABAYTUBE004A538 ............. Discharge Air Sensing Kit ....................................................... Y*C036-060(A or E)_RBAYTUBE006A538 ............. Discharge Air Sensing Kit ....................................................... Y*C036-060(A or E), Y*C072-120A_RBAYVNOR001B5r8 ............ Ventilation Override Kit ............................................................ Y*C036-060(A or E), Y*C072-120A_R1 Kits contain all necessary parts to achieve desired levelof enthalpy control.2 For use with ReliaTel microprocessor controlled unitsonly. Must be factory installed for Electromech<strong>an</strong>icalcontrolled units.3 Used for true discharge air sensing in both heating <strong>an</strong>dcooling. Required for supply air tempering.4 Lynn Haven M<strong>an</strong>ufacturing has a No-Return policy forthis roof curb.5 For use with ReliaTel controlled units only.6 C<strong>an</strong>not be used in conjunction with factory installedSmoke Detector option.7 Installs in ductwork for horizontal configuration. Fordownflow configuration, it installs in the unit's horizontalreturn duct. See Installer's Guide for more information.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.8 BAYABRD001C is required when ordering field installedaccessories Clogged Filter Switch (BAYDFPS003A), F<strong>an</strong>Fail Switch (BAYDFPS004A),Discharge Air Sensing Kit(BAYTUBE004A or BAYTUBE005A) or EvaporatorDefrost Control (Frostat) (BAYLOAM020B) VentilationOverride Kit (BAYVNOR001B) unless the followingoptions are factory installed: Frostat, Smoke Detector,Clogged Filter Switch, F<strong>an</strong> Failure Switch, Discharge AirSensing Kit. These factory installed options includethe ReliaTel Options Module.9 BAYQACB009A adapts Voyager BAYCURB021B toaccept Precedent 3 -5 ton unit. BAYQACB010A adaptsVoyager BAYCURB022B to accept Precedent 3-5 tonunit. BAYQACB012A adapts Voyager BAYCURB025B toaccept Precedent 6-10 ton unit. BAYQACB013A adaptsVoyager BAYCURB026B to accept Precedent 6-10 tonunit.BAYQACB011A adapts Voyager BAYCURB022B toaccept Precedent 6-10 ton unit.0 Electromech<strong>an</strong>ical controlled units onlyq Interface allows 3-10 ton units with ReliaTel Controlsto communicate with Tracer 100, Tracker, VariTrac II,<strong>an</strong>d is the preferred method of communication to TracerSummit.w Power Exhaust c<strong>an</strong>not be used with Barometric Relief.Order Economizer without Barometric Relief.e Activated on Power on.r Field installed accessory. Requires <strong>an</strong> economizer.t The m<strong>an</strong>ual outside air damper will ship factory suppliedwithin the unit, but must be field installed.y A=R-22, E=410APG-31 Effective 1/1/06


Precedent Packaged Gas/ElectricConvertible 3-10 TonsTable PG-32-A — Zone Sensors for ReliaTel Controlled UnitsModelNumber Description Used withBAYSENS006B ...... Single Setpoint M<strong>an</strong>ual Ch<strong>an</strong>geover .................................... Y*C036-120A_RBAYSENS008B ...... Dual Setpoint M<strong>an</strong>ual or Auto Ch<strong>an</strong>geover .......................... Y*C036-120A_RBAYSENS010B ...... Dual Setpoint M<strong>an</strong>. or Auto Ch<strong>an</strong>ge-over with System ........ Y*C036-120A_RFunction LightsBAYSENS019C ...... Programmable Night Setback w/System Function Lights ..... Y*C036-120A_RBAYSENS013C1 ... Room Sensor w/ Override <strong>an</strong>d C<strong>an</strong>cel Buttons .................... Y*C036-120A_RBAYSENS014C1 ... Room Sensor w/ Temp. Adjustment with Override <strong>an</strong>d ........ Y*C036-120A_RC<strong>an</strong>cel ButtonsBAYSENS017B ...... Remote Room Sensor .......................................................... BAYSENS006B,008B,010B,019CBAYSENS032A5 ... Dual Thermistor Remote Zone Sensor ................................. Y*C036-120A_RBAYSENS035A5 ... Digital Display Zone Sensor ................................................. Y*C036-120A_RBAYSENS036A4 ... Wall-Mounted Humidity Zone Sensor ................................... YHC120,3,4,WRBAYSENS037A4 ... Duct-Mounted Humidity Zone Sensor ................................... YHC120,3,4,WRBAYMTPL003B ...... Retrofit Wall Cover Plate Kit 7.25" x 6.0" .............................. BAYSENS019CBAYMTPL004B ...... Retrofit Wall Cover Plate Kit 4.75" x 4.75" ............................ BAYSENS006B,007B,010B,013,014C,017BTable PG-32-B — ThermostatsModelNumber Description Used withBAY28X1903 ............ Locking Thermostat Cover .................................................... Room ThermostatsBAYSTAT040B2 ..... Programmable Thermostat ................................................... Y*C036-120ATCONT200AN11AA Electronic, 1 Htg/1 CLG (non-prog) ...................................... Y*C036-090ABAYBASE008A ....... Subbase 1-Stage Heating/Cooling........................................ BAYSTAT040BBAYBASE006A ....... Subbase 2-Stage Heating/Cooling........................................ BAYSTAT040BBAYSENS033A ....... Remote Wall Sensor ............................................................. BAYSTAT040BBAYSENS034A ....... Remote Duct Sensor ............................................................ BAYSTAT040BBAYSTAT008 ........... M<strong>an</strong>ual 1-Stage Heating/Cooling .......................................... Y*C036-120ABAYSTAT010 .......... Auto 2-Stage Heating/Cooling .............................................. Y*C036-120A1 Used with Integrated Comfort TM Systems, <strong>an</strong>y unit type. These sensors do not work with TCM. Consult BASD Marketing for them.2 Requires use of BAYBASE006A or BAYBASE008A.3 Do not use with Programmable Thermostats.4 For use with Dehumidification (Hot Gas Reheat) Coil Option.5 For use with ReliaTel Controls only.* Either st<strong>an</strong>dard or high efficiency models.For additional Controls Information:See ReliaTel <strong>an</strong>d Micro Control features on PC-35 <strong>an</strong>d PC-36Effective 1/1/06PG-32For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Light Commercial Gas Electrics NewModel Number Quick ReferenceTable PG-33-A — Quick ReferencePrecedentPrecedentVoyager Horizontal Voyager Downflow Controls Ordering Number Service Model NumberYCD036C1L0B Micro-Proc YSC036*1RLA0000 YSC036*1RLA**000000000000Electro-Mech YSC036*1ELA0000 YSC036*1ELA**000000000000Medium Heat Micro-Proc YSC036*1RMA0000 YSC036*1RMA**000000000000Electro-Mech YSC036*1EMA0000 YSC036*1EMA**000000000000YCD036C1H0B Micro-Proc YSC036*1RHA0000 YSC036*1RHA**000000000000Electro-Mech YSC036*1EHA0000 YSC036*1EHA**000000000000YCD036C3L0B Micro-Proc YSC036*3RLA0000 YSC036*3RLA**000000000000Electro-Mech YSC036*3ELA0000 YSC036*3ELA**000000000000Medium Heat Micro-Proc YSC036*3RMA0000 YSC036*3RMA**000000000000Electro-Mech YSC036*3EMA0000 YSC036*3EMA**000000000000YCD036C3H0B Micro-Proc YSC036*3RHA0000 YSC036*3RHA**000000000000Electro-Mech YSC036*3EHA0000 YSC036*3EHA**000000000000YCD036C4L0B Micro-Proc YSC036*4RLA0000 YSC036*3RLA**000000000000Electro-Mech YSC036*4ELA0000 YSC036*3ELA**000000000000Medium Heat Micro-Proc YSC036*4RMA0000 YSC036*3RMA**000000000000Electro-Mech YSC036*4EMA0000 YSC036*3EMA**000000000000YCD036C4H0B Micro-Proc YSC036*4RHA0000 YSC036*4RHA**000000000000Electro-Mech YSC036*4EHA0000 YSC036*4EHA**000000000000YCH048C1L0B YCD048C1L0B Micro-Proc YSC048*1RLA0000 YSC048*1RLA**000000000000Electro-Mech YSC048*1ELA0000 YSC048*1ELA**000000000000Medium Heat Micro-Proc YSC048*1RMA0000 YSC048*1RMA**000000000000Electro-Mech YSC048*1EMA0000 YSC048*1EMA**000000000000YCH048C1H0B YCD048C1H0B Micro-Proc YSC048*1RHA0000 YSC048*1RHA**000000000000Electro-Mech YSC048*1EHA0000 YSC048*1EHA**000000000000YCH048C3L0B YCD048C3L0B Micro-Proc YSC048*3RLA0000 YSC048*3RLA**000000000000Electro-Mech YSC048*3ELA0000 YSC048*3ELA**000000000000Medium Heat Micro-Proc YSC048*3RMA0000 YSC048*3RMA**000000000000Electro-Mech YSC048*3EMA0000 YSC048*3EMA**000000000000YCH048C3H0B YCD048C3H0B Micro-Proc YSC048*3RHA0000 YSC048*3RHA**000000000000Electro-Mech YSC048*3EHA0000 YSC048*3EHA**000000000000YCH048C4L0B YCD048C4L0B Micro-Proc YSC048*4RLA0000 YSC048*4RLA**000000000000Electro-Mech YSC048*4ELA0000 YSC048*4ELA**000000000000Medium Heat Micro-Proc YSC048*4RMA0000 YSC048*4RMA**000000000000Electro-Mech YSC048*4EMA0000 YSC048*4EMA**000000000000YCH048C4H0B YCD048C4H0B Micro-Proc YSC048*4RHA0000 YSC048*4RHA**000000000000Electro-Mech YSC048*4EHA0000 YSC048*4EHA**000000000000YCH048CWL0B YCD048CWL0B Micro-Proc YSC048*WRLA0000 YSC048*WRLA**000000000000Electro-Mech YSC048*WELA0000 YSC048*WELA**000000000000Medium Heat Micro-Proc YSC048*WRMA0000 YSC048*WRMA**000000000000Electro-Mech YSC048*WEMA0000 YSC048*WEMA**000000000000YCH048CWH0B YCD048CWH0B Micro-Proc YSC048*WRHA0000 YSC048*WRHA**000000000000Electro-Mech YSC048*WEHA0000 YSC048*WEHA**000000000000NOTE: N/A indicates that <strong>an</strong> Ordering Number has not yet been set up for the indicated model.* Digit 7- A=R-22, E=410A.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-33 Effective 1/1/06


Light Commercial Gas Electrics NewModel Number Quick ReferenceTable PG-34-A — Quick ReferencePrecedentPrecedentVoyager Horizontal Voyager Downflow Controls Ordering Number Service Model NumberYCH060C1L0B YCD060C1L0B Micro-Proc YSC060*1RLA0000 YSC060*1RLA**000000000000Electro-Mech YSC060*1ELA0000 YSC060*1ELA**000000000000Medium Heat Micro-Proc YSC060*1RMA0000 YSC060*1RMA**000000000000Electro-Mech YSC060*1EMA0000 YSC060*1EMA**000000000000YCH060C1H0B YCD060C1H0B Micro-Proc YSC060*1RHA0000 YSC060*1RHA**000000000000Electro-Mech YSC060*1EHA0000 YSC060*1EHA**000000000000YCH060C3L0B YCD060C3L0B Micro-Proc YSC060*3RLA0000 YSC060*3RLA**000000000000Electro-Mech YSC060*3ELA0000 YSC060*3ELA**000000000000Medium Heat Micro-Proc YSC060*3RMA0000 YSC060*3RMA**000000000000Electro-Mech YSC060*3EMA0000 YSC060*3EMA**000000000000YCH060C3H0B YCD060C3H0B Micro-Proc YSC060*3RHA0000 YSC060*3RHA**000000000000Electro-Mech YSC060*3EHA0000 YSC060*3EHA**000000000000YCH060C4L0B YCD060C4L0B Micro-Proc YSC060*4RLA0000 YSC060*4RLA**000000000000Electro-Mech YSC060*4ELA0000 YSC060*4ELA**000000000000Medium Heat Micro-Proc YSC060*4RMA0000 YSC060*4RMA**000000000000Electro-Mech YSC060*4EMA0000 YSC060*4EMA**000000000000YCH060C4H0B YCD060C4H0B Micro-Proc YSC060*4RHA0000 YSC060*4RHA**000000000000Electro-Mech YSC060*4EHA0000 YSC060*4EHA**000000000000YCH060CWL0B YCD060CWL0B Micro-Proc YSC060*WRLA0000 YSC060*WRLA**000000000000Electro-Mech YSC060*WELA0000 YSC060*WELA**000000000000Medium Heat Micro-Proc YSC060*WRMA0000 YSC060*WRMA**000000000000Electro-Mech YSC060*WEMA0000 YSC060*WEMA**000000000000YCH060CWH0B YCD060CWH0B Micro-Proc YSC060*WRHA0000 YSC060*WRHA**000000000000Electro-Mech YSC060*WEHA0000 YSC060*WEHA**000000000000YCH074C3L0B YCD074C3L0B Micro-Proc YSC072*3RLA0000 YSC072*3RLA**000000000000Electro-Mech YSC072*3ELA0000 YSC072*3ELA**0000000000000Medium Heat Micro-Proc YSC072*3RMA0000 YSC072*3RMA**000000000000Electro-Mech YSC072*3EMA0000 YSC072*3EMA**000000000000YCH074C3H0B YCD074C3H0B Micro-Proc YSC072*3RHA0000 YSC072*3RHA**000000000000Electro-Mech YSC072*3EHA0000 YSC072*3EHA**000000000000YCH074C4L0B YCD074C4L0B Micro-Proc YSC072*4RLA0000 YSC072*3RLA**000000000000Electro-Mech YSC072*4ELA0000 YSC072*3ELA**000000000000Medium Heat Micro-Proc YSC072*4RMA0000 YSC072*3RMA**000000000000Electro-Mech YSC072*4EMA0000 YSC072*3EMA**000000000000YCH074C4H0B YCD074C4H0B Micro-Proc YSC072*4RHA0000 YSC072*4RHA**000000000000Electro-Mech YSC072*4EHA0000 YSC072*4EHA**000000000000Low Heat Micro-Proc YSC072*WRLA0000 YSC072*WRLA**000000000000Electro-Mech YSC072*WELA0000 YSC072*WELA**000000000000Medium Heat Micro-Proc YSC072*WRMA0000 YSC072*WRMA**000000000000Electro-Mech YSC072*WEMA0000 YSC072*WEMA**000000000000High Heat Micro-Proc YSC072*WRHA0000 YSC072*WRHA**000000000000Electro-Mech YSC072*WEHA0000 YSC072*WEHA**000000000000YCH075C3L0B YCD075C3L0B Micro-Proc YHC072*3RLA0000 YHC072*3RLA**000000000000Electro-Mech YHC072*3ELA0000 YHC072*3ELA**000000000000Medium Heat Micro-Proc YHC072*3RMA0000 YHC072*3RMA**000000000000Electro-Mech YHC072*3EMA0000 YHC072*3EMA**000000000000YCH075C3H0B YCD075C3H0B Micro-Proc YHC072*3RHA0000 YHC072*3RHA**000000000000Electro-Mech YHC072*3EHA0000 YHC072*3EHA**000000000000YCH075C4L0B YCD075C4L0B Micro-Proc YHC072*4RLA0000 YHC072*3RLA**000000000000Electro-Mech YHC072*4ELA0000 YHC072*3ELA**000000000000Medium Heat Micro-Proc YHC072*4RMA0000 YHC072*3RMA**000000000000Electro-Mech YHC072*4EMA0000 YHC072*3EMA**000000000000YCH075C4H0B YCD075C4H0B Micro-Proc YHC072*4RHA0000 YHC072*4RHA**000000000000Electro-Mech YHC072*4EHA0000 YHC072*4EHA**000000000000NOTE: N/A indicates that <strong>an</strong> Ordering Number has not yet been set up for the indicated model.* Digit 7- A=R-22, E=410A.Effective 1/1/06PG-34For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Light Commercial Gas Electrics NewModel Number Quick ReferenceTable PG-35-A — Quick ReferencePrecedentPrecedentVoyager Horizontal Voyager Downflow Controls Ordering Number Service Model NumberYCH075CWL0B YCD075CWL0B Micro-Proc YHC072AWRHA0000 YHC072AWRHA**000000000000Electro-Mech YHC072AWEHA0000 YHC072AWEHA**000000000000Medium Heat Micro-Proc YHC072AWRMA0000 YHC072AWRMA**000000000000Electro-Mech YHC072AWEMA0000 YHC072AWEMA**000000000000YCH075CWH0B YCD075CWH0B Micro-Proc YHC072AWRLA0000 YHC072A3RLA**000000000000Electro-Mech YHC072AWELA0000 YHC072A3ELA**000000000000YCH090D3L0B YCD090D3L0B Micro-Proc YSC090A3RLA0000 YSC090A3RLA**000000000000Electro-Mech YSC090A3ELA0000 YSC090A3ELA**000000000000Medium Heat Micro-Proc YSC090A3RMA0000 YSC090A3RMA**000000000000Electro-Mech YSC090A3EMA0000 YSC090A3EMA**000000000000YCH090D3H0B YCD090D3H0B Micro-Proc YSC090A3RHA0000 YSC090A3RHA**000000000000Electro-Mech YSC090A3EHA0000 YSC090A3EHA**000000000000YCH090D4L0B YCD090D4L0B Micro-Proc YSC090A4RLA0000 YSC090A4RLA**000000000000Electro-Mech YSC090A4ELA0000 YSC090A4ELA**000000000000Medium Heat Micro-Proc YSC090A4RMA0000 YSC090A4RMA**000000000000Electro-Mech YSC090A4EMA0000 YSC090A4EMA**000000000000YCH090D4H0B YCD090D4H0B Micro-Proc YSC090A4RHA0000 YSC090A4RHA**000000000000Electro-Mech YSC090A4EHA0000 YSC090A4EHA**000000000000YCH090DWL0B YCD090DWL0B Micro-Proc YSC090AWRLA0000 YSC090AWRLA**000000000000Electro-Mech YSC090AWELA0000 YSC090AWELA**000000000000Medium Heat Micro-Proc YSC090AWRMA0000 YSC090AWRMA**000000000000Electro-Mech YSC090AWEMA0000 YSC090AWEMA**000000000000YCH090DWH0B YCD090DWH0B Micro-Proc YSC090AWRHA0000 YSC090AWRHA**000000000000Electro-Mech YSC090AWEHA0000 YSC090AWEHA**000000000000YCH091D3L0B YCD091D3L0B Micro-Proc YHC090A3RLA**000000000000Electro-MechYHC090A3ELA**000000000000Medium Heat Micro-Proc YHC090A3RMA**000000000000Electro-MechYHC090A3EMA**000000000000YCH091D3H0B YCD091D3H0B Micro-Proc YHC090A3RHA**000000000000Electro-MechYHC090A3EHA**000000000000YCH091D4L0B YCD091D4L0B Micro-Proc YHC090A4RLA**000000000000Electro-MechYHC090A4ELA**000000000000Medium Heat Micro-Proc YHC090A4RMA**000000000000Electro-MechYHC090A4EMA**000000000000YCH091D4H0B YCD091D4H0B Micro-Proc YHC090A4RHA**000000000000Electro-MechYHC090A4EHA**000000000000Low Heat Micro-Proc YHC090AWRLA**000000000000Electro-MechYHC090AWELA**000000000000Medium Heat Micro-Proc YHC090AWRMA**000000000000Electro-MechYHC090AWEMA**000000000000High Heat Micro-Proc YHC090AWRHA**000000000000Electro-MechYHC090AWEHA**000000000000YCH102C3L0A YCD102C3L0A Micro-Proc YSC102A3RLA0000 YSC102A3RLA**000000000000Electro-Mech YSC102A3ELA0000 YSC102A3ELA**000000000000Medium Heat Micro-Proc YSC102A3RMA**000000000000Electro-Mech YSC102A3EMA0000 YSC102A3EMA**000000000000YCH102C3H0A YCD102C3H0A Micro-Proc YSC102A3RHA0000 YSC102A3RHA**000000000000Electro-Mech YSC102A3EHA0000 YSC102A3EHA**000000000000YCH102C4L0A YCD102C4L0A Micro-Proc YSC102A4RLA0000 YSC102A4RLA**000000000000Electro-Mech YSC102A4ELA0000 YSC102A4ELA**000000000000Medium Heat Micro-Proc YSC102A4RMA0000 YSC102A4RMA**000000000000Electro-Mech YSC102A4EMA0000 YSC102A4EMA**000000000000YCH102C4H0A YCD102C4H0A Micro-Proc YSC102A4RHA0000 YSC102A4RHA**000000000000Electro-Mech YSC102A4EHA0000 YSC102A4EHA**000000000000YCH102CWL0A YCD102CWL0A Micro-Proc YSC102AWRLA0000 YSC102AWRLA**000000000000Electro-Mech YSC102AWELA0000 YSC102AWELA**000000000000Medium Heat Micro-Proc YSC102AWRMA0000 YSC102AWRMA**000000000000Electro-Mech YSC102AWEMA0000 YSC102AWEMA**000000000000YCH102CWH0A YCD102CWH0A Micro-Proc YSC102AWRHA0000 YSC102AWRHA**000000000000Electro-Mech YSC102AWEHA0000 YSC102AWEHA**000000000000YCH103C3L0A YCD103C3L0A Micro-Proc YHC102A3RLA0000 YHC102A3RLA**000000000000Electro-Mech YHC102A3ELA0000 YHC102A3ELA**000000000000Medium Heat Micro-Proc YHC102A3RMA0000 YHC102A3RMA**000000000000Electro-Mech YHC102A3EMA0000 YHC102A3EMA**000000000000YCH103C3H0A YCD103C3H0A Micro-Proc YHC102A3RHA0000 YHC102A3RHA**000000000000Electro-Mech YHC102A3EHA0000 YHC102A3EHA**000000000000NOTE: N/A indicates that <strong>an</strong> Ordering Number has not yet been set up for the indicated model.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-35 Effective 1/1/06


Light Commercial Gas Electrics NewModel Number Quick ReferenceTable PG-36-A — Quick ReferencePrecedentPrecedentVoyager Horizontal Voyager Downflow Controls Ordering Number Service Model NumberYCH103C4L0A YCD103C4L0A Micro-Proc YHC102A4RLA0000 YHC102A4RLA**000000000000Electro-Mech YHC102A4ELA0000 YHC102A4ELA**000000000000Medium Heat Micro-Proc YHC102A4RMA0000 YHC102A4RMA**000000000000Electro-Mech YHC102A4EMA0000 YHC102A4EMA**000000000000YCH103C4H0A YCD103C4H0A Micro-Proc YHC102A4RHA0000 YHC102A4RHA**000000000000Electro-Mech YHC102A4EHA0000 YHC102A4EHA**000000000000YCH103CWL0A YCD103CWL0A Micro-Proc YHC102A4RLA0000 YHC102A4RLA**000000000000Electro-Mech YHC102A4ELA0000 YHC102A4ELA**000000000000Medium Heat Micro-Proc YHC102A4RMA0000 YHC102A4RMA**000000000000Electro-Mech YHC102A4EMA0000 YHC102A4EMA**000000000000YCH103CWH0A YCD103CWH0A Micro-Proc YHC102A4RHA0000 YHC102A4RHA**000000000000Electro-Mech YHC102A4EHA0000 YHC102A4EHA**000000000000YCH120C3L0A YCD120C3L0A Micro-Proc YSC120A3RLA0000 YSC120A3RLA**000000000000Electro-Mech YSC120A3ELA0000 YSC120A3ELA**000000000000YCH120C3M0A YCD120C3M0A Micro-Proc YSC120A3RMA0000 YSC120A3RMA**000000000000Electro-Mech YSC120A3EMA0000 YSC120A3EMA**000000000000YCH120B3H0E YCD120B3H0E Micro-Proc YSC120A3RHA0000 YSC120A3RHA**000000000000Electro-Mech YSC120A3EHA0000 YSC120A3EHA**000000000000YCH120C4L0A YCD120C4L0A Micro-Proc YSC120A4RLA0000 YSC120A4RLA**000000000000Electro-Mech YSC120A4ELA0000 YSC120A4ELA**000000000000YCH120C4M0A YCD120C4M0A Micro-Proc YSC120A4RMA0000 YSC120A4RMA**000000000000Electro-Mech YSC120A4EMA0000 YSC120A4EMA**000000000000YCH120B4H0E YCD120B4H0E Micro-Proc YSC120A4RHA0000 YSC120A4RHA**000000000000Electro-Mech YSC120A4EHA0000 YSC120A4EHA**000000000000YCH120CWL0A YCD120CWL0A Micro-Proc YSC120AWRLA0000 YSC120AWRLA**000000000000Electro-Mech YSC120AWELA0000 YSC120AWELA**000000000000YCH120CWM0A YCD120CWM0A Micro-Proc YSC120AWRMA0000 YSC120AWRMA**000000000000Electro-Mech YSC120AWEMA0000 YSC120AWEMA**000000000000YCH120BWH0E YCD120BWH0E Micro-Proc YSC120AWRHA0000 YSC120AWRHA**000000000000Electro-Mech YSC120AWEHA0000 YSC120AWEHA**000000000000YCH121C3L0A YCD121C3L0A Micro-Proc YHC120A3RLA0000 YHC120A3RLA**000000000000Electro-Mech YHC120A3ELA0000 YHC120A3ELA**000000000000Medium Heat Micro-Proc YHC120A3RMA0000 YHC120A3RMA**000000000000Electro-Mech YHC120A3EMA0000 YHC120A3EMA**000000000000YCH121C3H0A YCD121C3H0A Micro-Proc YHC120A3RHA0000 YHC120A3RHA**000000000000Electro-Mech YHC120A3EHA0000 YHC120A3EHA**000000000000YCH121C4L0A YCD121C4L0A Micro-Proc YHC120A4RLA0000 YHC120A4RLA**000000000000Electro-Mech YHC120A4ELA0000 YHC120A4ELA**000000000000Medium Heat Micro-Proc YHC120A4RMA0000 YHC120A4RMA**000000000000Electro-Mech YHC120A4EMA0000 YHC120A4EMA**000000000000YCH121C4H0A YCD121C4H0A Micro-Proc YHC120A4RHA0000 YHC120A4RHA**000000000000Electro-Mech YHC120A4EHA0000 YHC120A4EHA**000000000000YCH121CWL0A YCD121CWL0A Micro-Proc YHC120AWRLA0000 YHC120AWRLA**000000000000Electro-Mech YHC120AWELA0000 YHC120AWELA**000000000000Medium Heat Micro-Proc YHC120AWRMA0000 YHC120AWRMA**000000000000Electro-Mech YHC120AWEMA0000 YHC120AWEMA**000000000000YCH121CWH0A YCD121CWH0A Micro-Proc YHC120AWRHA0000 YHC120AWRHA**000000000000Electro-Mech YHC120AWEHA0000 YHC120AWEHA**000000000000NOTE: N/A indicates that <strong>an</strong> Ordering Number has not yet been set up for the indicated modeSee ReliaTel <strong>an</strong>d Micro Control features on PC-35 <strong>an</strong>d PC-36.Effective 1/1/06PG-36For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Precedent 3-5 ton 13 SEER R-22Packaged Gas ElectricsFeaturingA New Look for a New CenturyBeveled TopSmoother DesignSmall compact cabinetRecessed access h<strong>an</strong>dlesSt<strong>an</strong>dard Features:• <strong>Tr<strong>an</strong>e</strong> built scroll compressors on all 3-5 ton units• Colored <strong>an</strong>d numbered wiring• Provisions for through the Base Gas <strong>an</strong>d Condensate Drain Connections• Patented Hybrid Condenser Coil for easy cle<strong>an</strong>ing• 1" throwaway filters provided on 3-5 ton units• Liquid Line Refriger<strong>an</strong>t Drier• Operating Charge of R-22• IAQ Sloped Drain P<strong>an</strong>s• Low Ambient to 40°F on Electromech<strong>an</strong>ical models• Low Ambient to 0°F on Microprocessor models• 5 - year Limited Compressor Warr<strong>an</strong>ty• 5 - year Limited Heat Exch<strong>an</strong>ger Warr<strong>an</strong>ty• 1 - year Limited Parts Warr<strong>an</strong>tyAdded Flexibility• Electromech<strong>an</strong>ical or microprocessor controls (See page PC-35 for ReliaTelControl Information)• Low, medium or high heat, single or two stage• Convertible airflow• Fork lift openings on three sides of unit• Belt drive - st<strong>an</strong>dard or oversized motors• We don’t prepackage options• Choose options tailored to suit each job —pay only for what is needed• Units ship with options installed —<strong>an</strong>d within our st<strong>an</strong>dard ship cycle timeFactory Installed Options• Through-the-Base — Electrical• Convenience Outlet — Powered or unpowered• Unit Disconnect Switch• Smoke Detectors — Supply, return, or both• Condenser Coil Coating• Hinged Access Service P<strong>an</strong>els• Discharge Air Sensor• F<strong>an</strong> Fail <strong>an</strong>d Clogged Filter Switches• Condenser Coil Guard — Hail Protection Quality• Hot Gas Reheat Coil - Dehumidification• TXV thermal exp<strong>an</strong>sion valve <strong>an</strong>d split face evaporator coil st<strong>an</strong>dard• TCI (<strong>Tr<strong>an</strong>e</strong> Communication Interface)• LonTalk (Communication Interface)• 2" Pleated Media filters• Phase Monitor• FrostatThe same <strong>Tr<strong>an</strong>e</strong> Quality <strong>an</strong>dReliability … with added Flexibility!For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-37 Effective 1/1/06


Precedent Packaged Gas/ElectricConvertible 3-5 Tons 13 SEER R-22Table PG-38-A — Base Unit — 13 SEER High Efficiency — Electromech<strong>an</strong>icalHeating Output1 Cabinet ShippingUnit Perform<strong>an</strong>ce3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No. SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*YHC –208-230/3/60 – Three Phase – Low Heat3 YHC033A3ELA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 19.9 304 YHC043A3ELA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 22.6 355 YHC063A3ELA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45YHC –460/3/60 – Three Phase – Low Heat3 YHC033A4ELA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 10.4 154 YHC043A4ELA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 11.8 155 YHC063A4ELA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20YHC –575/3/60 – Three Phase – Low Heat3 YHC033AWELA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 7.7 154 YHC043AWELA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 8.5 155 YHC063AWELA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15YHC –208-230/3/60 – Three Phase – Medium Heat3 YHC033A3EMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 19.9 304 YHC043A3EMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 22.6 355 YHC063A3EMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45YHC –460/3/60 – Three Phase – Medium Heat3 YHC033A4EMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 10.4 154 YHC043A4EMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 11.8 155 YHC063A4EMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20YHC –575/3/60 – Three Phase – Medium Heat3 YHC033AWEMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 7.7 154 YHC043AWEMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 8.5 155 YHC063AWEMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15YHC –208-230/3/60 – Three Phase – High Heat3 YHC033A3EHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 19.9 304 YHC043A3EHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 22.6 355 YHC063A3EHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45YHC –460/3/60 – Three Phase – High Heat3 YHC033A4EHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 10.4 154 YHC043A4EHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 11.8 15YHC063A4EHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20YHC –575/3/60 – Three Phase – High Heat3 YHC033AWEHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 7.7 154 YHC043AWEHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 8.5 155 YHC063AWEHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.Effective 1/1/06PG-38For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Precedent Packaged Gas/ElectricConvertible 3-5 Tons 13 SEER R-22Table PG-39-A — Base Unit — 13 SEER High Efficiency — ReliaTel Microprocessor ControlsHeating Output1 Cabinet ShippingUnit Perform<strong>an</strong>ce3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No. SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*YHC –208-230/3/60 – Three Phase – Low Heat3 YHC033A3RLA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 19.9 304 YHC043A3RLA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 22.6 355 YHC063A3RLA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45YHC –460/3/60 – Three Phase – Low Heat3 YHC033A4RLA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 10.4 154 YHC043A4RLA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 11.8 155 YHC063A4RLA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20YHC –575/3/60 – Three Phase – Low Heat3 YHC033AWRLA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 7.7 154 YHC043AWRLA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 8.5 155 YHC063AWRLA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15YHC –208-230/3/60 – Three Phase – Medium Heat3 YHC033A3RMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 19.9 304 YHC043A3RMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 22.6 355 YHC063A3RMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45YHC –460/3/60 – Three Phase – Medium Heat3 YHC033A4RMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 10.4 154 YHC043A4RMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 11.8 155 YHC063A4RMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20YHC –575/3/60 – Three Phase – Medium Heat3 YHC033AWRMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 7.7 154 YHC043AWRMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 8.5 155 YHC063AWRMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15YHC –208-230/3/60 – Three Phase – High Heat3 YHC033A3RHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 19.9 304 YHC043A3RHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 22.6 355 YHC063A3RHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45YHC –460/3/60 – Three Phase – High Heat3 YHC033A4RHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 10.4 154 YHC043A4RHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 11.8 155 YHC063A4RHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20YHC –575/3/60 – Three Phase – High Heat3 YHC033AWRHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 7.7 154 YHC043AWRHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 8.5 155 YHC063AWRHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-39 Effective 1/1/06


Precedent Packaged Gas/ElectricConvertible 3-5 Tons 13 SEER R-22(Model Digit Numbers)Digit Description Order Number1-8 Main Assembly (see previous page)9 Unit ControlsElectromech<strong>an</strong>ical .................................................... EUnit Controls -ReliaTel Micro-processor .................. R10 Heating CapacityLow ......................................................................... LMedium .................................................................. MHigh ......................................................................... H11 Minor Design SequenceFirst Sequence ........................................................ A12-13 Service SequenceFirst Sequence (Factory assigned) .......................... ✱,✱14 Fresh Air SelectionNo Fresh Air ............................................................. 00-50% M<strong>an</strong>ual Outside Air Dampere ......................... A0-50% Motorized Outside Air Damper ........................ B0-100% Economizer, Dry Bulb withoutBarometric Relief2 ................................................ C0-100% Economizer, Dry Bulb withBarometric Relief2 ............................................... D0-100% Economizer, Reference Enthalpywithout Barometric Relief12 .................................. E0-100%Economizer, Reference Enthalpywith Barometric Relief12 ....................................... F0-100%Economizer, Comparative Enthalpywithout Barometric Relief 12 ................................ G0-100%Economizer, Comparative Enthalpywith Barometric Relief 12 ...................................... H15 Supply F<strong>an</strong>/Drive Type/MotorSt<strong>an</strong>dard Drive ......................................................... 016 Hinged Service Access & FiltersSt<strong>an</strong>dard P<strong>an</strong>els & Filters ......................................... 0Hinged Access P<strong>an</strong>els & St<strong>an</strong>dard Filters .................. ASt<strong>an</strong>dard p<strong>an</strong>els & 2" Pleated Filters .......................... BHinged Access P<strong>an</strong>els & 2" Pleated Filters ................ C17 Condenser Coil ProtectionSt<strong>an</strong>dard Coil ........................................................... 0St<strong>an</strong>dard Coil with Hail Guard ................................... 1Epoxy Coated Condenser Coil .................................. 2Epoxy Coated Condenser Coil with Hail Guard .......... 318 Through the Base ProvisionsNo Through the Base Provisions ............................... 0Through the Base Electrict ...................................... AThrough the Base Gas ............................................. BThrough the Base Gas <strong>an</strong>d Electricw ........................ C1 Enthalpy control not available factory installed with electro-mech<strong>an</strong>ical controls.2 Economizer with Barometric Relief is for downfllow configured units only. OrderEconomizer without Barometric Relief for horizontal configuration. Barometric relief forhorizontal configured units must be ordered as field installed accessory BAYBARM010A.3 Requires use of Disconnect or Circuit Breaker.4 St<strong>an</strong>dard refrigeration metering device - short orifice.5 Frostat c<strong>an</strong>not be field installed in electro-mech<strong>an</strong>ical units.6 High Pressure control is st<strong>an</strong>dard on 3 phase units with scroll compressors <strong>an</strong>d inYSC036A.7 Not available with BAYFRST001A High Temperature Stat accessory.8 The return air smoke detector may not fit up or work properly on the Precedent unitswhen used in conjunction with 3rd party accessories such as bolt on heat wheels,economizers <strong>an</strong>d power exhaust. Do not order the return air smoke detectors whenusing this type of accessory.Digit Description Order Number19 Disconnect/Circuit Breaker/Phase Monitor (3 phase only)No Disconnect Circuit Breaker/No Phase Monitor ....... 0Non-Fused Disconnectt ........................................... 1Circuit Breakert ....................................................... 2Phase Monitory ....................................................... 3Phase Monitory & Non-Fused Disconnect Switch ...... 4Phase Monitory & Circuit Breaker ............................. 520 Convenience OutletNo Convenience Outlet ............................................. 0Unpowered Convenience Outlet ............................... APowered Convenience Outlet (3 phase only)3 ........... B21 Communications OptionsuNo Communications Interface ................................... 0<strong>Tr<strong>an</strong>e</strong> Communications Interface ............................... 1LonTalk ® Communications Interface .......................... 2Novar 2024 Controls ................................................. 3Novar 3051 Controls ................................................. 422 Refrigeration System OptionSt<strong>an</strong>dard Refrigeration System withThermal Exp<strong>an</strong>sion Value ....................................... 0Dehumidification (Hot Gas Reheat Coil)r .................. B23 Refrigeration ControlsNo Refrigeration Control ........................................... 0High Pressure Control6u ......................................... 1Frostat5 .................................................................. 2Cr<strong>an</strong>kcase Heater .................................................... 3High Pressure Control6u <strong>an</strong>d Frostat5 ..................... 4High Pressure Control6u <strong>an</strong>d Cr<strong>an</strong>kcase Heater ....... 5Frostat5 <strong>an</strong>d Cr<strong>an</strong>kcase Heater6 ............................. 6High Pressure Control6u, Frostat5 <strong>an</strong>dCr<strong>an</strong>kcase Heater6 .............................................. 724 Smoke Detector7uNo Smoke Detector .................................................. 0Return Air Smoke Detector89 .................................. ASupply Air Smoke Detector ....................................... BSupply <strong>an</strong>d Return Air Smoke Detectors89 ............... C25 Monitoring ControlsuNo Monitoring Control0 ............................................ 0Clogged Filter Switch0 ............................................. 1F<strong>an</strong> Failure Switch0 ................................................. 2Discharge Air Sensing Tube0 ................................... 3Clogged Filter Switch <strong>an</strong>d F<strong>an</strong> Fail Switch0 ............... 4Clogged Filter Switch <strong>an</strong>d DischargeAir Sensing Tube0 ................................................ 5F<strong>an</strong> Fail Switch <strong>an</strong>d Discharge Air Sensing Tube0 ..... 6Clogged Filter <strong>an</strong>d F<strong>an</strong> Fail Switches<strong>an</strong>d Discharge Air Sensing Tube0 .......................... 7Novar Return Air Sensorq ........................................ 89 Return Air Smoke Detector c<strong>an</strong>not be ordered with Novar Controls.0 These options are st<strong>an</strong>dard when ordering Novar Controls.q This option is used when ordering Novar Controls.w Includes gas piping <strong>an</strong>d shutoff (field assembly required).e The m<strong>an</strong>ual outside air damper will ship factory supplied within the unit, but must be fieldinstalled.r Requires Selection of 2" Pleated Filters (Option B or C) for Digit 16.t Through the base electric required when ordering disconnect/circuit breaker options.y Phase Monitor is st<strong>an</strong>dard on T/Y/WSC060A3,4,W models. All other models PhaseMonitor is <strong>an</strong> option.u Not available with electro-mech<strong>an</strong>ical controls.Effective 1/1/06PG-40For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Precedent Packaged Gas/ElectricConvertible 3-5 Tons 13 SEER R-22Table PG-41-A — AccessoriesModel Number Description Used WithBAYABRD001C5 ................... ReliaTel Options Module ..................................................... See Note8BAYASCT0010w .................... Anti-Short-Cycle Timer ........................................................... YHC033-063A_EBAYBARM010A7 ................... Barometric Relief .................................................................... YHC033-063ABAYCCHT010B ...................... Cr<strong>an</strong>kcase Heater ................................................................... YHC033-063A3BAYCCHT011B ...................... Cr<strong>an</strong>kcase Heater ................................................................... YHC033-063A4,AWBAYCO2K001B5e ................ CO 2 Sensor Kit, Wall Mounted ................................................ YHC033-063A_RBAYCO2K003B5e ................ CO 2 Sensor Kit, Duct Mounted ............................................... YHC033-063A_RBAYCURB042A4 ................... Roof Curb ............................................................................... YHC033-063ABAYDFPS003A58 ................. Clogged Filter Switch .............................................................. YHC033-063A_RBAYDFPS004A58 ................. F<strong>an</strong> Failure Switch .................................................................. YHC033-063A_RBAYDMPR051A5 .................. 0-50% Motorized Outside Air Damper .................................... YHC033-063ABAYDMPR052A0 .................. 0-50% Motorized Outside Air Damper .................................... YHC033-063A_EBAYDMPR053Br .................. 0-50% M<strong>an</strong>ual Outside Air Damper ........................................ YHC033-063ABAYECON085A5 .................. 0-100% Dry Bulb Economizer without Barometric Relief ....... YHC033-063A_RBAYECON086A0 .................. 0-100% Dry Bulb Economizer without Barometric Relief ....... YHC033-063A_EBAYENTH005A1 ................... Reference Enthalpy Kit ........................................................... BAYECON085ABAYENTH006A1 ................... Comparative Enthalpy Kit ....................................................... BAYECON085ABAYENTH001A ...................... Enthalpy Control (Solid State .................................................. BAYECON086ABAYFRST001A56 ................. High Temperature Stat ............................................................ YHC033,063A_RBAYGARD036B ..................... Condenser Coil Hail Guard ..................................................... YHC033-043A**L,MBAYGARD037B ..................... Condenser Coil Hail Guard ..................................................... YHC033-043A**H,YHC063A**L,M,HBAYHAKT010B ...................... High Altitude Kit ...................................................................... YHC033-063ABAYHSMT073A ..................... .45 HP Oversized motor kit ..................................................... YHC033A3BAYHSMT074A ..................... .45 HP Oversized motor kit ..................................................... YHC033A4BAYHSMT075A ..................... .45 HP Oversized motor kit ..................................................... YHC033AWBAYHSMT076A ..................... .75 HP Oversized motor kit ..................................................... YHC043A3BAYHSMT077A ..................... .75 HP Oversized motor kit ..................................................... YHC043A4BAYHSMT078A ..................... .75 HP Oversized motor kit ..................................................... YHC043AWBAYHSMT079A ..................... 1.2 HP Oversized motor kit ..................................................... YHC063A3BAYHSMT080A ..................... 1.2 HP Oversized motor kit ..................................................... YHC063A4BAYHSMT081A ..................... 1.2 HP Oversized motor kit ..................................................... YHC063AWBAYICSI003A5q ................... <strong>Tr<strong>an</strong>e</strong> Communications Interface (TCI) ................................... YHC033-063A_RBAYLOAM020B28 ................ Evaporator Defrost Control (Frostat) ....................................... YHC033-063A_RBAYLPKT028B ....................... LP Conversion Kit ................................................................... YHC033-063ABAYLTCI002B5 ...................... LonTalk ® Communications Interface (LCI) .............................. YHC033-063A_RBAYQACB009A49 ................ Quick Adapt Curb ................................................................... YHC033-063ABAYQACB010A49 ................ Quick Adapt Curb ................................................................... YHC033-063ABAYSENS016A5 ................... Temperature Sensor ............................................................... YHC033-063A_RBAYSERV001A5 ................... Selective Resist<strong>an</strong>ce Service Tester ...................................... YHC033-063A_RBAYSTAT0235 ....................... Remote Potentiometer ............................................................ BAYECON085ABAYTUBE004A358 .............. Discharge Air Sensing Kit ....................................................... YHC033-063A_RBAYTUBE006A358 .............. Discharge Air Sensing Kit ....................................................... YHC033-063A_RBAYVNOR001B58e ............. Ventilation Override Kit ........................................................... YHC033-063A_R1 Kits contain all necessary parts to achieve desired levelof enthalpy control.2 For use with ReliaTel microprocessor controlled unitsonly. Must be factory installed for Electromech<strong>an</strong>icalcontrolled units.3 Used for true discharge air sensing in both heating <strong>an</strong>dcooling. Required for supply air tempering.4 Lynn Haven M<strong>an</strong>ufacturing has a No-Return policy forthis roof curb.5 For use with ReliaTel controlled units only.6 C<strong>an</strong>not be used in conjunction with factory installedSmoke Detector option.7 Installs in ductwork for horizontal configuration. Fordownflow configuration, it installs in the unit's horizontalreturn duct. See Installer's Guide for more information.8 BAYABRD001C is required when ordering field installedaccessories Clogged Filter Switch (BAYDFPS003A),F<strong>an</strong> Fail Switch (BAYDFPS004A),Discharge Air SensingKit (BAYTUBE004A or BAYTUBE005A) or EvaporatorDefrost Control (Frostat) (BAYLOAM020B) VentilationOverride Kit (BAYVNOR001B) unless the followingoptions are factory installed: Frostat, Smoke Detector,Clogged Filter Switch, F<strong>an</strong> Failure Switch, Discharge AirSensing Kit. These factory installed options includethe ReliaTel Options Module.9 BAYQACB009A adapts Voyager BAYCURB021B toaccept Precedent 3 -5 ton unit. BAYQACB010A adaptsVoyager BAYCURB022B to accept Precedent 3-5 tonunit. BAYQACB012A adapts Voyager BAYCURB025B toaccept Precedent 6-10 ton unit. BAYQACB013A adaptsVoyager BAYCURB026B to accept Precedent 6-10 tonunit.BAYQACB011A adapts Voyager BAYCURB022B toaccept Precedent 6-10 ton unit.0 Electromech<strong>an</strong>ical controlled units onlyq Interface allows 3-10 ton units with ReliaTel Controlsto communicates with Tracer 100, Tracker, VariTrac II,<strong>an</strong>d is the preferred method of communication to TracerSummit.w Activated on Power on.e Field installed accessory. Requires <strong>an</strong> economizer.r The m<strong>an</strong>ual outside air damper will ship factory suppliedwithin the unit, but must be field installed.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-41 Effective 1/1/06


Precedent Packaged Gas/ElectricConvertible 3-5 Tons 13 SEER R-22Table PG-42-A — Zone Sensors for ReliaTel Controlled UnitsModelNumber Description Used withBAYSENS006B ...... Single Setpoint M<strong>an</strong>ual Ch<strong>an</strong>geover .................................... YHC033-063A_RBAYSENS008B ...... Dual Setpoint M<strong>an</strong>ual or Auto Ch<strong>an</strong>geover .......................... YHC033-063A_RBAYSENS010B ...... Dual Setpoint M<strong>an</strong>. or Auto Ch<strong>an</strong>ge-over with System ........ YHC033-063A_RFunction LightsBAYSENS019C2 ... Programmable Night Setback w/System Function Lights ..... YHC033-063A_RBAYSENS013C1 ... Room Sensor w/ Override <strong>an</strong>d C<strong>an</strong>cel Buttons .................... YHC033-063A_RBAYSENS014C1 ... Room Sensor w/ Temp. Adjustment with Override <strong>an</strong>d ........ YHC033-063A_RC<strong>an</strong>cel ButtonsBAYSENS017B ...... Remote Room Sensor .......................................................... BAYSENS006B,008B,010B,019CBAYSENS032A6 ... Dual Thermistor Remote Zone Sensor ................................. YHC033-063A_RBAYSENS035A6 ... Digital Display Zone Sensor ................................................. YHC033-063A_RBAYSENS036A5 ... Wall-Mounted Humidity Zone Sensor ................................... YHC033-063A3,4,WRBAYSENS037A5 ... Duct-Mounted Humidity Zone Sensor ................................... YHC033-063A3,4,WRBAYMTPL003B ...... Retrofit Wall Cover Plate Kit 7.25" x 6.0" .............................. BAYSENS019CBAYMTPL004B ...... Retrofit Wall Cover Plate Kit 4.75" x 4.75" ............................ BAYSENS006B,007B,010B,013,014C,017BTable PG-42-B — ThermostatsModelNumber Description Used withBAY28X1903 ............ Locking Thermostat Cover .................................................... Room ThermostatsBAYSTAT040B2 ..... Programmable Thermostat ................................................... YHC033-063ATCONT200AN11AA Electronic, 1 Htg/1 CLG (non-prog) ...................................... YHC033-063ABAYBASE008A ....... Subbase 1-Stage Heating/Cooling........................................ BAYSTAT040BBAYBASE006A ....... Subbase 2-Stage Heating/Cooling........................................ BAYSTAT040BBAYSENS033A ....... Remote Wall Sensor ............................................................. BAYSTAT040BBAYSENS034A ....... Remote Duct Sensor ............................................................ BAYSTAT040BBAYSTAT008 ........... M<strong>an</strong>ual 1-Stage Heating/Cooling .......................................... YHC033-063ABAYSTAT010 .......... Auto 2-Stage Heating/Cooling .............................................. YHC033-063A1 Used with Integrated Comfort TM Systems, <strong>an</strong>y unit type. These sensors do not work with TCM. Consult BASD Marketing for them.2 Requires use of BAYBASE006A or BAYBASE008A.3 Do not use with Programmable Thermostats.4 Use only with electromech<strong>an</strong>ical unit controls.5 For use with Dehumidification (Hot Gas Reheat) Coil Option.6 For use with ReliaTel Controls only.* Either st<strong>an</strong>dard or high efficiency models.For additional Controls Information:See ReliaTel <strong>an</strong>d Micro Control features on PC-35 <strong>an</strong>d PC-36.Effective 1/1/06PG-42For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Voyager PackagedGas/Electric with ReliaTelControls 12½ through 15 TonsYCD — Downflow• EER up to 11.5• <strong>Tr<strong>an</strong>e</strong> built scroll compressors• Scroll compressors on all models• ReliaTel control features are listed onpage PC-35• Built-in <strong>an</strong>ti-short cycle timer, time delayrelay <strong>an</strong>d minimum on time controls• Low Ambient to 0°F st<strong>an</strong>dard• High efficiency drum <strong>an</strong>d tube heatexch<strong>an</strong>ger• Color coded <strong>an</strong>d numbered wiring• Two inch filters on both YCH <strong>an</strong>d YCD tocle<strong>an</strong> air <strong>an</strong>d keep coil mainten<strong>an</strong>ce low• Simple U-shaped airflow pattern results invery low airside energy requirement• “Quick-Access” doors <strong>an</strong>d single sideaccess make servicing much faster forlower mainten<strong>an</strong>ce costs• Quick-adjust idler arm pulley. Adjust belttension, ch<strong>an</strong>ge belts, adjust airflowquickly• High efficiency gas heat with hot surfaceignition for low heating energy costs, lowmainten<strong>an</strong>ce <strong>an</strong>d high reliability• IAQ sloped condensate drain p<strong>an</strong>s• 5-year limited compressor warr<strong>an</strong>ty(12½-15 tons)• 5-year limited heat exch<strong>an</strong>ger warr<strong>an</strong>ty(12½-15 tons)• 1 year limited parts warr<strong>an</strong>tyTable PG-43-A — Downflow — Micro Control UnitCooling Heating Output Shipping Max Fuse SizeUnit Power Supply Perform<strong>an</strong>ce Capacity Capacity Dimensions (in.) Weight or1 Max DownflowTons Model No. Volts/Phase/Hz EER (3Ø) (Btuh) (Btuh) H x W x L (Ibs.) MCA* Circuit Breaker* Roofcurb12 1 /2 YCD150D3L0B 208-230/3/60 9.6 150,000 122,000 50 1 /8 x 71 5 /16 x 107 5 /16 1826 63 80 BAYCURB026B12 1 /2 YCD150D4L0B 460/3/60 9.6 150,000 122,000 50 1 /8 x 71 5 /16 x 107 5 /16 1826 33 40 BAYCURB026B12 1 /2 YCD150DWL0B 575/3/60 9.6 150,000 122,000 50 1 /8 x 71 5 /16 x 107 5 /16 1826 26 30 BAYCURB026B12 1 /2 YCD150D3H0B 208-230/3/60 9.6 150,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 1826 63 80 BAYCURB026B12 1 /2 YCD150D4H0B 460/3/60 9.6 150,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 1826 33 40 BAYCURB026B12 1 /2 YCD150DWH0B 575/3/60 9.6 150,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 1826 26 30 BAYCURB026B12 1 /2 YCD151C3L0B 208-230/3/60 11.3 154,000 122,000 50 1 /8 x 71 5 /16 x 107 5 /16 1915 64 80 BAYCURB026B12 1 /2 YCD151C4L0B 460/3/60 11.3 154,000 122,000 50 1 /8 x 71 5 /16 x 107 5 /16 1915 31 40 BAYCURB026B12 1 /2 YCD151CWL0B 575/3/60 11.3 154,000 122,000 50 1 /8 x 71 5 /16 x 107 5 /16 1915 25 30 BAYCURB026B12 1 /2 YCD151C3H0B 208-230/3/60 11.3 154,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 1915 64 80 BAYCURB026B12 1 /2 YCD151C4H0B 460/3/60 11.3 154,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 1915 31 40 BAYCURB026B12 1 /2 YCD151CWH0B 575/3/60 11.3 154,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 1915 25 30 BAYCURB026B15 YCD180B3L0H 208-230/3/60 9.7 182,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 2033 78 90 BAYCURB026B15 YCD180B4L0H 460/3/60 9.7 182,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 2033 39 50 BAYCURB026B15 YCD180BWL0H 575/3/60 9.7 182,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 2033 31 40 BAYCURB026B15 YCD180B3H0H 208-230/3/60 9.7 182,000 284,000 50 1 /8 x 71 5 /16 x 107 5 /16 2033 78 90 BAYCURB026B15 YCD180BWH0H 575/3/60 9.7 182,000 284,000 50 1 /8 x 71 5 /16 x 107 5 /16 2033 31 40 BAYCURB026B15 YCD180B4H0H 460/3/60 9.7 182,000 284,000 50 1 /8 x 71 5 /16 x 107 5 /16 2033 39 50 BAYCURB026B15 YCD181C3L0C 208-230/3/60 11.5 189,000 203,000 54 x 85 5 /16 x 122 5 /16 2464 74 90 BAYCURB027B15 YCD181C4L0C 460/3/60 11.5 189,000 203,000 54 x 85 5 /16 x 122 5 /16 2464 36 50 BAYCURB027B15 YCD181CWL0C 575/3/60 11.5 189,000 203,000 54 x 85 5 /16 x 122 5 /16 2464 29 40 BAYCURB027B15 YCD181C3H0C 208-230/3/60 11.5 189,000 284,000 54 x 85 5 /16 x 122 5 /16 2464 74 90 BAYCURB027B15 YCD181C4H0C 460/3/60 11.5 189,000 284,000 54 x 85 5 /16 x 122 5 /16 2464 36 50 BAYCURB027B15 YCD181CWH0C 575/3/60 11.5 189,000 284,000 54 x 85 5 /16 x 122 5 /16 2464 29 40 BAYCURB027BUnit Supply Return Curb Size Roof OpeningModel No.Downflow W x L23Downflow W x L23H x W x L24W x L23YC❋150,151, 180 28 9 /16 x 55 1 /2 20 7 /8 x 63 14 1 /16 x 66 15 /16 x 102 1 /4 62 1 /2 x 73 1 /2YC❋181 28 9 /16 x 69 1 /2 22 1 /4 x 77 14 1 /16 x 80 15 /16 x 117 1 /8 76 1 /2 x 81Note: L = Low Heat H = High Heat in ninth digit1 HACR Type Circuit Breaker per NEC.2 Dimensions are in inches. See Outline Dimensions.3 Interior Dimension.4 Measurement Includes Curb Fl<strong>an</strong>ge.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-43 Effective 1/1/06


Voyager PackagedGas/Electric with ReliaTelControls 17½ through 25 TonsYCD — Downflow• EER up to 11.5• Scroll compressors on all units• ReliaTel control features are listed on pagePC-35• Built-in <strong>an</strong>ti-short cycle timer, time delay relay<strong>an</strong>d minimum on time controls• Low Ambient to 0°F st<strong>an</strong>dard• High efficiency drum <strong>an</strong>d tube heat exch<strong>an</strong>ger• Color coded <strong>an</strong>d numbered wiring• Two inch filters on both YCH <strong>an</strong>d YCD to cle<strong>an</strong>air <strong>an</strong>d keep coil mainten<strong>an</strong>ce low• Simple U-shaped airflow pattern results in verylow airside energy requirement• “Quick-Access” doors <strong>an</strong>d single side accessmake servicing much faster for lowermainten<strong>an</strong>ce costs• Quick-adjust idler arm pulley. Adjust belttension, ch<strong>an</strong>ge belts, adjust airflow quickly• High efficiency gas heat with hot surfaceignition for low heating energy costs, lowmainten<strong>an</strong>ce <strong>an</strong>d high reliability• IAQ sloped condensate drain p<strong>an</strong>s• 5-year limited compressor warr<strong>an</strong>ty(17½ tons)• 1-year limited compressor warr<strong>an</strong>ty(20 <strong>an</strong>d 25 tons)• 5-year limited heat exch<strong>an</strong>ger warr<strong>an</strong>ty(17½ tons)• 1-year limited heat exch<strong>an</strong>ger warr<strong>an</strong>ty (20<strong>an</strong>d 25 tons)• 1 year limited parts warr<strong>an</strong>tyTable PG-44-A — Downflow — Micro Control UnitCooling Heating Output Shipping Max Fuse SizeUnit Power Supply Perform<strong>an</strong>ce Capacity Capacity Dimensions (in.) Weight or1 Max DownflowTons Model No. Volts/Phase/Hz EER (3Ø) (Btuh) (Btuh) H x W x L (Ibs.) MCA* Circuit Breaker* Roofcurb17 1 /2 YCD210C3L0E 208-230/3/60 9.6 210,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 2189 88 100 BAYCURB026B17 1 /2 YCD210C4L0E 460/3/60 9.6 210,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 2189 44 50 BAYCURB026B17 1 /2 YCD210CWL0E 575/3/60 9.6 210,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 2189 35 45 BAYCURB026B17 1 /2 YCD210C3H0E 208-230/3/60 9.6 210,000 284,000 50 1 /8 x 71 5 /16 x 107 5 /16 2189 88 100 BAYCURB026B17 1 /2 YCD210C4H0E 460/3/60 9.6 210,000 284,000 50 1 /8 x 71 5 /16 x 107 5 /16 2189 44 50 BAYCURB026B17 1 /2 YCD210CWH0E 575/3/60 9.6 210,000 284,000 50 1 /8 x 71 5 /16 x 107 5 /16 2189 35 45 BAYCURB026B17 1 /2 YCD211C3L0C 208-230/3/60 11.0 220,000 203,000 54 x 85 5 /16 x 122 5 /16 2547 91 110 BAYCURB027B17 1 /2 YCD211C4L0C 460/3/60 11.0 220,000 203,000 54 x 85 5 /16 x 122 5 /16 2547 44 60 BAYCURB027B17 1 /2 YCD211CWL0C 575/3/60 11.0 220,000 203,000 54 x 85 5 /16 x 122 5 /16 2547 35 45 BAYCURB027B17 1 /2 YCD211C3H0C 208-230/3/60 11.0 220,000 284,000 54 x 85 5 /16 x 122 5 /16 2547 91 110 BAYCURB027B17 1 /2 YCD211C4H0C 460/3/60 11.0 220,000 284,000 54 x 85 5 /16 x 122 5 /16 2547 44 60 BAYCURB027B17 1 /2 YCD211CWH0C 575/3/60 11.0 220,000 284,000 54 x 85 5 /16 x 122 5 /16 2547 35 45 BAYCURB027B20 YCD240B3L0J 208-230/3/60 9.5 242,000 203,000 54 x 85 5 /16 x 122 5 /16 2547 100 125 BAYCURB027B20 YCD240B4L0J 460/3/60 9.5 242,000 203,000 54 x 85 5 /16 x 122 5 /16 2547 50 60 BAYCURB027B20 YCD240BWL0J 575/3/60 9.5 242,000 203,000 54 x 85 5 /16 x 122 5 /16 2547 40 45 BAYCURB027B20 YCD240B3H0J 208-230/3/60 9.5 242,000 324,000 54 x 85 5 /16 x 122 5 /16 2547 100 125 BAYCURB027B20 YCD240B4H0J 460/3/60 9.5 242,000 324,000 54 x 85 5 /16 x 122 5 /16 2547 50 60 BAYCURB027B20 YCD240BWH0J 575/3/60 9.5 242,000 324,000 54 x 85 5 /16 x 122 5 /16 2547 40 45 BAYCURB027B20 YCD241C3L0C 208-230/3/60 10.6 268,000 203,000 54 x 85 5 /16 x 122 5 /16 2645 99 125 BAYCURB027B20 YCD241C4L0C 460/3/60 10.6 268,000 203,000 54 x 85 5 /16 x 122 5 /16 2645 50 60 BAYCURB027B20 YCD241CWL0C 575/3/60 10.6 268,000 203,000 54 x 85 5 /16 x 122 5 /16 2645 40 50 BAYCURB027B20 YCD241C3H0C 208-230/3/60 10.6 268,000 324,000 54 x 85 5 /16 x 122 5 /16 2645 99 125 BAYCURB027B20 YCD241C4H0C 460/3/60 10.6 268,000 324,000 54 x 85 5 /16 x 122 5 /16 2645 50 60 BAYCURB027B20 YCD241CWH0C 575/3/60 10.6 268,000 324,000 54 x 85 5 /16 x 122 5 /16 2645 40 50 BAYCURB027B25 YCD300B3L0H 208-230/3/60 9.7 290,000 203,000 54 x 85 5 /16 x 122 5 /16 2541 118 150 BAYCURB027B25 YCD300B4L0H 460/3/60 9.7 290,000 203,000 54 x 85 5 /16 x 122 5 /16 2541 58 70 BAYCURB027B25 YCD300BWL0H 575/3/60 9.7 290,000 203,000 54 x 85 5 /16 x 122 5 /16 2541 46 50 BAYCURB027B25 YCD300B3H0H 208-230/3/60 9.7 290,000 324,000 54 x 85 5 /16 x 122 5 /16 2541 118 150 BAYCURB027B25 YCD300B4H0H 460/3/60 9.7 290,000 324,000 54 x 85 5 /16 x 122 5 /16 2541 58 70 BAYCURB027B25 YCD300BWH0H 575/3/60 9.7 290,000 324,000 54 x 85 5 /16 x 122 5 /16 2541 46 50 BAYCURB027B25 YCD301C3L0C 208-230/3/60 10.4 300,000 203,000 54 x 85 5 /16 x 122 5 /16 2650 120 150 BAYCURB027B25 YCD301C4L0C 460/3/60 10.4 300,000 203,000 54 x 85 5 /16 x 122 5 /16 2650 58 70 BAYCURB027B25 YCD301CWL0C 575/3/60 10.4 300,000 203,000 54 x 85 5 /16 x 122 5 /16 2650 47 60 BAYCURB027B25 YCD301C3H0C 208-230/3/60 10.4 300,000 324,000 54 x 85 5 /16 x 122 5 /16 2650 120 150 BAYCURB027B25 YCD301C4H0C 460/3/60 10.4 300,000 324,000 54 x 85 5 /16 x 122 5 /16 2650 58 70 BAYCURB027B25 YCD301CWH0C 575/3/60 10.4 300,000 324,000 54 x 85 5 /16 x 122 5 /16 2650 47 60 BAYCURB027BUnit Supply Return Curb Size Roof OpeningModel No.Downflow W x L23Downflow W x L23H x W x L24W x L23YC❋210 28 9 /16 x 55 1 /2 20 7 /8 x 63 14 1 /16 x 66 15 /16 x 102 1 /4 62 1 /2 x 73 1 /2YC❋211, 240, 241, 300 28 9 /16 x 69 1 /2 22 1 /4 x 77 14 1 /16 x 80 15 /16 x 117 1 /8 76 1 /2 x 81Note: L = Low Heat H = High Heat in ninth digit1 HACR Type Circuit Breaker per NEC.2 Dimensions are in inches. See Outline Dimensions.3 Interior Dimension.4 Measurement Includes Curb Fl<strong>an</strong>ge.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.Effective 1/1/06PG-44For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Voyager PackagedGas/Electric with ReliaTelControls 12½ through 15 TonsYCH — Horizontal• EER up to 11.5• Scroll compressors on all units• ReliaTel control features are listed onpage PC-35• Built-in <strong>an</strong>ti-short cycle timer, time delayrelay <strong>an</strong>d minimum on time controls• Low Ambient to 0°F st<strong>an</strong>dard• High efficiency drum <strong>an</strong>d tube heatexch<strong>an</strong>ger• Color coded <strong>an</strong>d numbered wiring• Two inch filters on both YCH <strong>an</strong>d YCD tocle<strong>an</strong> air <strong>an</strong>d keep coil mainten<strong>an</strong>ce low• Simple U-shaped airflow pattern results invery low airside energy requirement• “Quick-Access” doors <strong>an</strong>d single sideaccess make servicing much faster forlower mainten<strong>an</strong>ce costs• Quick-adjust idler arm pulley. Adjustbelt tension, ch<strong>an</strong>ge belts, adjustairflow quickly• High efficiency gas heat with hot surfaceignition for low heatingenergy costs, low mainten<strong>an</strong>ce<strong>an</strong>d high reliability• IAQ sloped condensate drain p<strong>an</strong>s• 5-year limited compressor warr<strong>an</strong>ty(12½-15 tons)• 5-year limited heat exch<strong>an</strong>ger warr<strong>an</strong>ty(12½-15 tons)• 1 year limited parts warr<strong>an</strong>tyTable PG-45-A — Horizontal — Micro Control UnitShippingMax Fuse SizeUnit Power Supply Perform<strong>an</strong>ce Cooling Heating Output Dimensions (in.) Weight or1 MaxTons Model No. Volts/Phase/Hz EER (3Ø) Capacity (Btuh) Capacity (Btuh) H x W x L (Ibs.) MCA* Circuit Breaker*12 1 /2 YCH150D3L0B 208-230/3/60 9.6 150,000 122,000 50 1 /8 x 71 5 /16 x 107 5 /16 1826 63 8012 1 /2 YCH150D4L0B 460/3/60 9.6 150,000 122,000 50 1 /8 x 71 5 /16 x 107 5 /16 1826 33 4012 1 /2 YCH150DWL0B 575/3/60 9.6 150,000 122,000 50 1 /8 x 71 5 /16 x 107 5 /16 1826 26 3012 1 /2 YCH150D3H0B 208-230/3/60 9.6 150,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 1826 63 8012 1 /2 YCH150D4H0B 460/3/60 9.6 150,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 1826 33 4012 1 /2 YCH150DWH0B 575/3/60 9.6 150,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 1826 26 3012 1 /2 YCH151C3L0B 208-230/3/60 11.3 154,000 122,000 50 1 /8 x 71 5 /16 x 107 5 /16 1915 64 8012 1 /2 YCH151C4L0B 460/3/60 11.3 154,000 122,000 50 1 /8 x 71 5 /16 x 107 5 /16 1915 31 4012 1 /2 YCH151DWL0B 575/3/60 11.3 154,000 122,000 50 1 /8 x 71 5 /16 x 107 5 /16 1915 25 3012 1 /2 YCH151C3H0B 208-230/3/60 11.3 154,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 1915 64 8012 1 /2 YCH151C4H0B 460/3/60 11.3 154,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 1915 31 4012 1 /2 YCH151DWH0B 575/3/60 11.3 154,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 1915 25 3015 YCH180B3L0H 208-230/3/60 9.7 182,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 2033 78 9015 YCH180B4L0H 460/3/60 9.7 182,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 2033 39 5015 YCH180BWL0H 575/3/60 9.7 182,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 2033 31 4015 YCH180B3H0H 208-230/3/60 9.7 182,000 284,000 50 1 /8 x 71 5 /16 x 107 5 /16 2033 78 9015 YCH180B4H0H 460/3/60 9.7 182,000 284,000 50 1 /8 x 71 5 /16 x 107 5 /16 2033 39 5015 YCH180BWH0H 575/3/60 9.7 182,000 284,000 50 1 /8 x 71 5 /16 x 107 5 /16 2033 31 4015 YCH181C3L0C 208-230/3/60 11.5 189,000 203,000 54 x 85 5 /16 x 122 5 /16 2464 74 9015 YCH181C4L0C 460/3/60 11.5 189,000 203,000 54 x 85 5 /16 x 122 5 /16 2464 36 5015 YCH181CWL0C 575/3/60 11.5 189,000 203,000 54 x 85 5 /16 x 122 5 /16 2464 29 4015 YCH181C3H0C 208-230/3/60 11.5 189,000 284,000 54 x 85 5 /16 x 122 5 /16 2464 74 9015 YCH181C4H0C 460/3/60 11.5 189,000 284,000 54 x 85 5 /16 x 122 5 /16 2464 36 5015 YCH181CWH0C 575/3/60 11.5 189,000 203,000 54 x 85 5 /16 x 122 5 /16 2464 29 40Unit Supply ReturnModel No.Horizontal H x W23Horizontal H x W23YC❋150C 41 7 /16 x 22 1 /2 41 7 /16 x 17 3 /16YC❋151, 180 42 1 /2 x 26 1 /2 42 1 /2 x 24 9 /16YC❋181 46 7 /16 x 26 1 /2 46 7 /16 x 27 9 /16Note: L = Low Heat H = High Heat in ninth digit1 HACR Type Circuit Breaker per NEC.2 Dimensions are in inches. See Outline Dimensions.3 Interior Dimension.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-45 Effective 1/1/06


Voyager PackagedGas/Electric with ReliaTelControls 17½ through 25 TonsYCH — Horizontal• EER up to 11.5• Scroll compressors on all units• ReliaTel control features are listed on pagePC-35• Built-in <strong>an</strong>ti-short cycle timer, time delay relay<strong>an</strong>d minimum on time controls• Low Ambient to 0°F st<strong>an</strong>dard• High efficiency drum <strong>an</strong>d tube heat exch<strong>an</strong>ger• Color coded <strong>an</strong>d numbered wiring• Two inch filters on both YCH <strong>an</strong>d YCD to cle<strong>an</strong>air <strong>an</strong>d keep coil mainten<strong>an</strong>ce low• Simple U-shaped airflow pattern results in verylow airside energy requirement• “Quick-Access” doors <strong>an</strong>d single side accessmake servicing much faster for lowermainten<strong>an</strong>ce costs• Quick-adjust idler arm pulley. Adjust belttension, ch<strong>an</strong>ge belts, adjust airflow quickly• High efficiency gas heat with hot surfaceignition for low heating energy costs, lowmainten<strong>an</strong>ce <strong>an</strong>d high reliability• IAQ sloped condensate drain p<strong>an</strong>s• 5-year limited compressor warr<strong>an</strong>ty(17½ tons)• 1-year limited compressor warr<strong>an</strong>ty(20 <strong>an</strong>d 25 tons)• 5-year limited heat exch<strong>an</strong>ger warr<strong>an</strong>ty(17½ tons)• 1-year limited heat exch<strong>an</strong>ger warr<strong>an</strong>ty(20 <strong>an</strong>d 25 tons)• 1 year limited parts warr<strong>an</strong>tyTable PG-46-A — Horizontal — Micro Control UnitMax Fuse SizeShippingMax Fuse SizeUnit Power Supply Perform<strong>an</strong>ce Cooling Heating Output Dimensions (in.) Weight or1 MaxTons Model No. Volts/Phase/Hz EER (3Ø) Capacity (Btuh) Capacity (Btuh) H x W x L (Ibs.) MCA* Circuit Breaker*17 1 /2 YCH210C3L0E 208-230/3/60 9.6 210,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 2189 88 11017 1 /2 YCH210C4L0E 460/3/60 9.6 210,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 2189 44 5017 1 /2 YCH210CWL0E 575/3/60 9.6 210,000 203,000 50 1 /8 x 71 5 /16 x 107 5 /16 2189 35 4517 1 /2 YCH210C3H0E 208-230/3/60 9.6 210,000 284,000 50 1 /8 x 71 5 /16 x 107 5 /16 2189 88 11017 1 /2 YCH210C4H0E 460/3/60 9.6 210,000 284,000 50 1 /8 x 71 5 /16 x 107 5 /16 2189 44 507 1 /2 YCH210CWH0E 575/3/60 9.6 210,000 284,000 50 1 /8 x 71 5 /16 x 107 5 /16 2189 35 4517 1 /2 YCH211C3L0C 208-230/3/60 11.0 220,000 203,000 54 x 85 5 /16 x 122 5 /16 2547 91 11017 1 /2 YCH211C4L0C 460/3/60 11.0 220,000 203,000 54 x 85 5 /16 x 122 5 /16 2547 44 6017 1 /2 YCH211CWL0C 575/3/60 11.0 220,000 203,000 54 x 85 5 /16 x 122 5 /16 2547 35 4517 1 /2 YCH211C3H0C 208-230/3/60 11.0 220,000 284,000 54 x 85 5 /16 x 122 5 /16 2547 91 11017 1 /2 YCH211C4H0C 460/3/60 11.0 220,000 284,000 54 x 85 5 /16 x 122 5 /16 2547 44 6017 1 /2 YCH211CWH0C 575/3/60 11.0 220,000 284,000 54 x 85 5 /16 x 122 5 /16 2547 35 4520 YCH240B3L0J 208-230/3/60 9.5 242,000 203,000 54 x 85 5 /16 x 122 5 /16 2547 100 12520 YCH240B4L0J 460/3/60 9.5 242,000 203,000 54 x 85 5 /16 x 122 5 /16 2547 50 6020 YCH240BWL0J 575/3/60 9.5 242,000 203,000 54 x 85 5 /16 x 122 5 /16 2547 40 4520 YCH240B3H0J 208-230/3/60 9.5 242,000 324,000 54 x 85 5 /16 x 122 5 /16 2547 100 12520 YCH240B4H0J 460/3/60 9.5 242,000 324,000 54 x 85 5 /16 x 122 5 /16 2547 50 6020 YCH240BWH0J 575/3/60 9.5 242,000 324,000 54 x 85 5 /16 x 122 5 /16 2547 40 4520 YCH241C3L0C 208-230/3/60 10.6 268,000 203,000 54 x 85 5 /16 x 122 5 /16 2645 99 12520 YCH241C4L0C 460/3/60 10.6 268,000 203,000 54 x 85 5 /16 x 122 5 /16 2645 50 6020 YCH241CWL0C 575/3/60 10.6 268,000 203,000 54 x 85 5 /16 x 122 5 /16 2645 40 5020 YCH241C3H0C 208-230/3/60 10.6 268,000 324,000 54 x 85 5 /16 x 122 5 /16 2645 99 12520 YCH241C4H0C 460/3/60 10.6 268,000 324,000 54 x 85 5 /16 x 122 5 /16 2645 50 6020 YCH241CWH0C 575/3/60 10.6 268,000 324,000 54 x 85 5 /16 x 122 5 /16 2645 40 5025 YCH300B3L0H 208-230/3/60 9.3 290,000 203,000 54 x 85 5 /16 x 122 5 /16 2541 118 15025 YCH300B4L0H 460/3/60 9.3 290,000 203,000 54 x 85 5 /16 x 122 5 /16 2541 58 7025 YCH300BWL0H 575/3/60 9.3 290,000 203,000 54 x 85 5 /16 x 122 5 /16 2541 46 5025 YCH300B3H0H 208-230/3/60 9.3 290,000 324,000 54 x 85 5 /16 x 122 5 /16 2541 118 15025 YCH300B4H0H 460/3/60 9.3 290,000 324,000 54 x 85 5 /16 x 122 5 /16 2541 58 7025 YCH300BWH0H 575/3/60 9.3 290,000 324,000 54 x 85 5 /16 x 122 5 /16 2541 46 5025 YCH301C3L0C 208-230/3/60 10.4 300,000 203,000 54 x 85 5 /16 x 122 5 /16 2650 120 15025 YCH301C4L0C 460/3/60 10.4 300,000 203,000 54 x 85 5 /16 x 122 5 /16 2650 58 7025 YCH301CWL0C 575/3/60 10.4 300,000 203,000 54 x 85 5 /16 x 122 5 /16 2650 47 6025 YCH301C3H0C 208-230/3/60 10.4 300,000 324,000 54 x 85 5 /16 x 122 5 /16 2650 120 15025 YCH301C4H0C 460/3/60 10.4 300,000 324,000 54 x 85 5 /16 x 122 5 /16 2650 58 7025 YCH301CWH0C 575/3/60 10.4 300,000 324,000 54 x 85 5 /16 x 122 5 /16 2650 47 60Unit Supply ReturnModel No.Horizontal H x W23Horizontal H x W23YC❋ 210 42 1 /2 x 26 1 /2 42 1 /2 x 24 9 /16YC❋211, 240, 241, 300 46 7 /16 x 26 1 /2 46 7 /16 x 27 9 /16Note: L = Low Heat H = High Heat in ninth digit1 HACR Type Circuit Breaker per NEC.2 Dimensions are in inches. See Outline Dimensions.3 Interior Dimension.* Information subject to ch<strong>an</strong>ge. Please confirm with current Product Data/Service Facts for current factory production.Effective 1/1/06PG-46For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Voyager PackagedGas/Electric with ReliaTelControls12½ through 25 TonsTable PG-47-A —Factory Installed Accessories12 For Complete list of all Factory Installed Options, please refer to the FIOPSsection of this book.Digit Description Order Number Used With1-9 Main Assembly (see previous page)10 Factory Installed OptionsNo Options 0 YC*150-301Downflow Economizer3 A YCD150-301Oversized Motor B YC*150-241Downflow Economizer <strong>an</strong>d Oversized Motor3 C YCD150-241<strong>Tr<strong>an</strong>e</strong> Communications Interface (TCI)4 F YC*150-301Downflow Economizer TCI34 G YCD150-301TXV/Face - Split Evaporator H YCD151, 181, 211, 241, 301Oversized Motor <strong>an</strong>d TXV/Face -Split Evaporator J YCD151, 181, 211, 241Downflow Economizer, Oversized Motor <strong>an</strong>d TXV/Face K YCD151, 181, 211, 241Split Evaporator3Downflow Economizer with TXV/Face - Split Evaporator3 L YCD151, 181, 211, 241, 301Reheat Coil5 M YCD151, 181, 241Downflow Economizer with Reheat Coil35 N YCD151, 181, 241Oversized Motor <strong>an</strong>d Reheat Coil5 P YCD151, 181, 241Downflow Economizer, Oversized Motor <strong>an</strong>d R YCD151, 181, 241Reheat Coil 3511-12 Minor Design <strong>an</strong>d Service Sequence **1 Price includes accessory <strong>an</strong>d factory installation.2 Four (4) week shipping approximately.3 Some field set up required.4 TCI is for use with non-VariTrac systems <strong>an</strong>d VariTrac systems.5 All 10th digit model numbers including reheat coil (M,N,P,R) require additional factory installed options; ReliaTel options module (FIYABRD002B), Frostat(FIYLOAM023A), <strong>an</strong>d 2" pleated filters (FIYPLTD001A, 002A, or 003A refer to FIOPS section for appropriate model number usage). For these or <strong>an</strong>y Factory InstalledOptions not included in 10th digit model number, digits 1-3 must be YFD.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-47 Effective 1/1/06


Voyager Packaged Gas/Electricwith ReliaTel Controls12½ through 25 Tons AccessoriesTable PG-48-A — Field Installed Accessories For complete list of of All Factory Installed Options refer to FIOPS section of this book.Model Number Description Used WithBAYABRD002Bq ........ ReliaTel Options Module ................................................ YCD/YCH150-301BAYCO2K002Bw ........ CO 2 Sensor Wall Mounted ................................................. YC*150-301 w/EconomizerBAYCO2K004Bw ........ CO 2 Sensor Duct Mounted ................................................ YC*150-301 w/EconomizerBAYCURB026B67 ..... Downflow Only Roof Curb ................................................. YCD150D, 151C, 180B, 210CBAYCURB027B67 ..... Downflow Only Roof Curb ................................................. YCD181C, 211-301BAYDFPS005A9q ...... Clogged Filter Switch ........................................................ YCD/YCH (12½-25 Tons)BAYDFPS006A9q ...... F<strong>an</strong> Failure Switch ............................................................. Economizers/0-50% Motorized Outside Air DampersBAYDMPR029C .......... 0-25% M<strong>an</strong>ual Outside Air Damper ................................... YCD/YCH (12½-25 Tons)BAYDMPR057A .......... 0-50% Motorized Outside Air Damper ............................... YCD/YCH150D, 151C, 180B, 210CBAYDMPR058A .......... 0-50% Motorized Outside Air Damper ............................... YCD/YCH181, 211-301BAYECON089Aq ........ Downflow Economizer with Barometric Relief ................... YCD150D, 151C, 180B, YCD210CBAYECON090Aq ........ Downflow Economizer with Barometric Relief ................... YCD181C, 211, 240B, 241C, 300B, 301CBAYECON091A .......... Horizontal Economizer ...................................................... YCH150D, 151C, 180B, YCH210CBAYECON092A .......... Horizontal Economizer ...................................................... YCH181C, 211-301BAYENTH007A12 .... Reference Enthalpy Kit ...................................................... All BAYECON089A-092ABAYENTH008A123 .. Comparative Enthalpy Kit ................................................. All BAYECON089A-092ABAYFRST003A ........... High Temperature Stat ...................................................... YCD/YCH150DBAYGARD043Bq ........ Tool-less Hail Guard .......................................................... YC*150DBAYGARD044Bq ........ Tool-less Hail Guard .......................................................... YC*151C, 180B, 210CBAYGARD045Aq ........ Tool-less Hail Guard .......................................................... YC*181C, 211C, 240B,241C, 301CBAYGARD047Aq ........ Tool-less Hail Guard .......................................................... YC*300BBAYHSDR002B4 ....... High Static Drive ................................................................ YCD/YCH151CBAYHSDR005B4 ....... High Static Drive ................................................................ YCD/YCH150D,180B, 211C, 240B, 241BBAYHSDR010A ........... High Static Drive ................................................................ YCD/YCH300B, 301CBAYHSDR011A ........... High Static Drive ................................................................ YCD/YCH181CBAYHSMT039B4q .... 5 HP Oversized Motor Kit .................................................. YCD/YCH150D,151C, 180BBAYHSMT040Bq ........ 5 HP Oversized Motor Kit .................................................. YCD/YCH150DWBAYHSMT042A5q .... 7-1/2HP Oversized Motor Kit (575V) ................................. YC*211C, 240B, 241CWBAYHSMT055B4q .... 5HP Oversized Motor Kit ................................................... YCD/YCH181CBAYHSMT059A5q .... 7-1/2HP Oversized Motor Kit (230V) ................................. YCD/YCH210CBAYHSMT060A5q .... 7-1/2HP Oversized Motor Kit (460V) ................................. YCD/YCH210CBAYHSMT061A5q .... 7-1/2HP Oversized Motor Kit (575V) ................................. YC*210CWBAYHSMT072A5q .... 7-1/2HP Oversized Motor Kit (575V) ................................. YC*181CWBAYHSMT098A5q ..... 7-1/2HP Oversized Motor Kit .............................................. YC*211,240,241C3BAYHSMT099A5q ..... 7-1/2HP Oversized Motor Kit .............................................. YC*211,240,241C4BAYICSI004B0e.......... <strong>Tr<strong>an</strong>e</strong> Comunications Interface, Comm 3/4 (TCI) ................... YC*150-301BAYLOAM023A9 ......... Evaporator Defrost Control ................................................... YCD150-301BAYLPKT018A ............ LP Conversion Kit .............................................................. YCD/YCH150D,151-301CBAYLSDR004A5 ....... Low Static Drive ................................................................. YCD/YCH210CBAYLSDR002A5 ....... Low Static Drive ................................................................. YCD/YCH300B, 301CBAYLTCI003B0 ........... LonTalk ® Communications Interface (LCI) ......................... YC*150-301BAYPWRX029A .......... Power Exhaust for 230 volt units ....................................... BAYECON062-089A,063-090A,065-091A,066-092A (YCD150D, 151-301C)BAYPWRX030A .......... Power Exhaust for 460 volt units ....................................... BAYECON062-089A,063-090A,065-091A,066-092A (YCD150D, 151-301C)BAYPWRX031A .......... Power Exhaust for use with Downflow Economizer(575V) ........ YCD150DWBAYSENS016A ........... Temperature Sensor .......................................................... YCD/YCH (12½-25 Tons)BAYSERV001A ........... Selective Resist<strong>an</strong>ce Service Tester ................................. YCD/YCH (12½-25 Tons)BAYSTAT0237 ........... Remote Potentiometer ....................................................... All BAYECON089-92ABAYTUBE008A9q ...... Discharge Air Sensing Kit .................................................. YCD150D-301BAYTUBE009A9q ...... Discharge Air Sensing Kit .................................................. YCH150-301BAYVNOR002B9 ........ Ventilation Override Kit ...................................................... YCD/YCH150-301 w/Reliatel Options ModuleTable PG-48-B — Zone SensorsBAYMTPL003B ........... Retrofit Wall Cover Plate Kit (7 1 /4" x 6") ............................................. BAYSENS019CBAYMTPL004B ........... Retrofit Wall Cover Plate Kit (4 3 /4" x 4 3 /4") .......................................... BAYSENS006B, 008B, 010B, 017B, 013C, 014CBAYSENS006B ........... Single Setpoint M<strong>an</strong>ual Ch<strong>an</strong>geover ................................................. YC*150-301BAYSENS008B ........... Dual Setpoint M<strong>an</strong>ual or Auto Ch<strong>an</strong>geover ....................................... YC*150-301BAYSENS010B ........... Dual Setpoint M<strong>an</strong>. or Auto Ch<strong>an</strong>geover with Sys. Funct. Light ......... YC*150-301BAYSENS013C8 ....... Room Sensor with Override Button ................................................... YC*150-301BAYSENS014C8 ....... Room Sensor with Temperature Adjustment <strong>an</strong>d Override .............. YC*150-301BAYSENS017B ........... Remote Room Sensor ....................................................................... BAYSENS006B, 008B, 010B, 019CBAYSENS019C ........... Programmable Night Setback with System Function Lights .............. YC*150-301BAYSENS032A0 ........ Dual Thermistor Remote Zone Sensor .............................................. YC*150-301BAYSENS035A0 ........ Digital Display Zone Sensor ............................................................... YC*150-300BAYSENS036A ........... Wall-Mounted Humidity Sensor ......................................................... YFD151,181,241 (with Reheat)BAYSENS037A ........... Duct-Mounted Humidity Sensor ......................................................... YFD151,181,241 (with Reheat)1 Kit contains all necessary parts to achieve desired level of Enthalpy Control.2 Reference Enthalpy senses outside temperature/humidity <strong>an</strong>d inside supply air only.3 Comparative Enthalpy senses outside temperature/humidity <strong>an</strong>d inside supply <strong>an</strong>dreturn air.4 High static drive <strong>an</strong>d oversized motors are mutually exclusive, Do Not Combine.5 Low static drive <strong>an</strong>d oversized motors are mutually exclusive, Do Not Combine.6 See Accessory IOM for operational characteristics.7 Clarksville M<strong>an</strong>ufacturing has a no-return policy for this roof curb.See ReliaTel <strong>an</strong>d Micro Control features on PC-35 <strong>an</strong>d PC-36.Effective 1/1/06PG-488 Used with Integrated Comfort Systems TM <strong>an</strong>y unit type. These sensors do not work withTCM. Consult BASD Marketing for them.9 BAYABRD002 is required when ordering BAYDFPS005A or 006A, BAYTUBE008A or009A <strong>an</strong>d BAYLOAM023A or BAYVNOR002B.0 Functional only with ReliaTel controls.q Field or factory installed option.* Either horizontal or downflow modelsw Field installed accessory. Requires <strong>an</strong> economizer.e Interface allows a unit with ReliaTel Controls to communicate with Tracer 100,Tracker, VariTrac II, <strong>an</strong>d is the preferred method of communication to Tracer Summit.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Voyager Packaged Unit Accessories12 1 /2 through 25 Tons12 1/2 – 25 Ton Packaged Gas/Electric, Electric/Electric <strong>an</strong>d HeatPumpAGEDSCFactory SuppliedAccessoriesUnitYCD/H, TCD/H, WCD/HCoil Guard (3-7 1/2 Ton)(BAYGARD)Economizer (Downflow <strong>an</strong>dHorizontal) (BAYECON)Fresh Air Damper (BAYDMPR)M<strong>an</strong>ual (3-25 Ton) (0-25%)Motorized (5-25 Ton Only) (0-50%)Sensor/ThermostatCurb (BAYCURB)QAPEQuick Adapt Curb...Field Supplied(8 1/2-25 Ton Only) (BAYCURB)Power Exhaust (BAYPWRX)(6 1/4-25 Ton Only) (BAYPWRX)For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.PG-49 Effective 1/1/06


Voyager Factory Installed OptionsCommercial Packaged Units 12½ through 25 Tons<strong>Tr<strong>an</strong>e</strong> offers a variety of factory installed options (FIOPS) for the light commercial packaged rooftop product line. These optionsare in addition to the st<strong>an</strong>dard factory installed options, i.e., downflow economizer <strong>an</strong>d oversized motors.Black Epoxy Coated Condenser Coil – Black Epoxy coil protection is a factory-applied,thermoset vinyl coating that is bonded to the aluminum fin stockprior to the fin stamping process. The pre-coated coils are <strong>an</strong> economical optionfor protection in mildly corrosive environments.Dehumidification Option – The dehumidification (hot gas reheat) option shallbe a factory-installed option that provides increased dehumidification. Theoption shall consist of a hot-gas reheat coil located on the leaving air side of theevaporator coil prepiped <strong>an</strong>d circuited. The option shall be equipped withcr<strong>an</strong>kcase heater(s), low pressure switch(es), Frostat, <strong>an</strong>d a thermostaticexp<strong>an</strong>sion valve(s) (TXV) as st<strong>an</strong>dard.Differential Pressure Switches – A dedicated differential pressure switch isavailable to achieve active f<strong>an</strong> failure indication <strong>an</strong>d/or clogged filter indication.These indications will be registered on a zone sensor with status indicationlights. This option is available for all 12½ – 25 ton models.Electric Heaters – Factory installed <strong>an</strong>d wired electric heatersare available for all 230, 460, <strong>an</strong>d 575 volt 3-phase horizontal <strong>an</strong>d downflow12½ – 25 ton models. If ordering the Through the Base Electrical option with <strong>an</strong>Electric Heater, the heater must be factory installed.High Efficiency Motors – Available with efficiency ratings from 86.5 up to 91.0.Check unit specifications for specific motor size per unit model.Hinged Access Doors – Sheet metal hinges are available factory installed onthe Filter/Evaporator Access Door <strong>an</strong>d the Compressor/Control Access Door ofall 12½ – 25 ton downflow units.Powered or Unpowered Convenience Outlet – This option is a GFCI, 120volt/15 amp, 2 plug, convenience outlet, either powered or unpowered. Whenthe convenience outlet is powered, a service receptacle disconnect will beavailable. The convenience outlet is powered from the line side of thedisconnect or circuit breaker, <strong>an</strong>d therefore will not be affected by the positionof the disconnect or circuit breaker.This option is available for all 12½– 25 ton downflow units <strong>an</strong>d c<strong>an</strong> only beordered when the Through the Base Electrical with either the Disconnect Switchor Circuit Breaker option is ordered.Reference or Comparative Enthalpy – When a factory installed DownflowEconomizer is ordered, <strong>an</strong> option will be to factory install either Reference orComparative Enthalpy Control.Supply <strong>an</strong>d Return Air Smoke Detector – With this option installed, if smokeis detected the line will shut down all operation. Reset will be m<strong>an</strong>ual at the unit.Smoke detectors are photo cell.Through the Base Electrical with Circuit Breaker – This optionis a factory installed thermal magnetic, molded case, HACR Circuit Breakerwith provisions for through the base electrical connections. The circuit breakerwill be installed in a water tight enclosure in the unit with access through aswinging door. Factory wiring will be provided from the switch to the unit highvoltage terminal block. The circuit breaker will provide overcurrent protection,be sized per NEC <strong>an</strong>d UL guidelines, <strong>an</strong>d be agency recognized by UL/CSA.This option is available for all 12½ – 25 ton downflow models. Either a CircuitBreaker or a Disconnect Switch (not both) must be ordered when ordering theThrough the Base Electrical option.* Some FIOPs available only for certaintonnages, unit functions, or efficiencies.Before Ordering:Not all factory options are offered for single phase units.Please contact the Clarksville, TN Support Team for latest updates offactory installed options <strong>an</strong>d ordering instructions.Call (931) 645-6471 <strong>an</strong>d ask to be connected to the Light CommercialProduct Support Team.Through the Base Electrical with Disconnect Switch – Factory installed 3-pole, molded case disconnect switch with provisions for through the base electricalconnections are available. The disconnect switch will be installed in the unit ina water tight enclosure with access through a swinging door. Factory wiring willbe provided from the switch to the unit high voltage terminal block. The switchwill be UL/CSA agency recognized. Note: The disconnect switchwill be sized per NEC <strong>an</strong>d UL guidelines but will not be used in place of unitovercurrent protection.This option is available for all 230, 460 <strong>an</strong>d 575 volt, 3-phase downflow 12½ – 25ton models. Either a Circuit Breaker or a Disconnect Switch (not both) must beordered when ordering the Through the Base Electrical option.Through the Base Gas Piping – With this option, provision willbe made in the unit for installing through the base gas piping. The option willhave all piping necessary including a pre-assembled, black steel, m<strong>an</strong>ual gasshut-off valve, elbows <strong>an</strong>d union. The m<strong>an</strong>ual shut-off valve shall include a 1/8inch NPT pressure tap. This assembly will require minor field labor to install.This option is available for all 12½ – 25 ton downflow gas/electric units, <strong>an</strong>d c<strong>an</strong>only be ordered when the Through the Base Electrical Option with Disconnect orCircuit Breaker is ordered.Thermal Exp<strong>an</strong>sion Valve (TXV) <strong>an</strong>d Face Split Evaporator – All units have ashort orifice refriger<strong>an</strong>t control metering device. For more exact refriger<strong>an</strong>t flow,when using units in low airflow or high outside air applications, a ThermalExp<strong>an</strong>sion Valve option shall be available. This is available on High EfficiencyGas/Cooling units only.Discharge Air Sensing Kit – This option provides true discharge air sensing inheating models. This sensor is a status indicator readable through Tracer® orTracker®. The kit is functional only with the ReliaTel Module.Coil Guards – Hail protection quality coil guards shall be either factory or fieldinstalledfor condenser coil protection.High Efficiency Motors – This option is available with efficiency ratings from86.5 up to 91.0. Not available for all models.Supply <strong>an</strong>d/or Return Air Smoke Detector – With this option installed, if smokeis detected, all unit operation will be shut down. Reset will be m<strong>an</strong>ual at the unit.Return Air Smoke Detectors require minimum allowable airflow when used withcertain models. See the Installation, Operation, <strong>an</strong>d Mainten<strong>an</strong>ce (IOM) m<strong>an</strong>ualfor the models affected <strong>an</strong>d the minimum allowable airflow required. This optionis available on all 12½-25 tons downflow models.Frostat – This factory or field installed option is to be utilized as a safety device.The Frostat opens when temperatures on the evaporator coil fall below 10°F. Thetemperature will need to rise to 50°F before closing. This option should be utilizedin low airflow or high outside air applications.Through the Base Utilities Access – An electrical service entr<strong>an</strong>ce shall beprovided allowing electrical access for both control <strong>an</strong>d main power connectioninside the curb <strong>an</strong>d through the base of the unit. Option will allow for fieldinstallation of liquid-tight conduit <strong>an</strong>d <strong>an</strong> external field installed disconnect switch.Novar Unit Controls – Novar rooftop unit controls will be factor installed <strong>an</strong>dtested. The Novar electronic thermostat module will interface to the unitmicroprocessor <strong>an</strong>d will control the unit to the desired stage of cooling or heating.The Novar electronic thermostat module will monitor the following unitinformation: f<strong>an</strong> failure status, cooling stage 1-on status, cooling stage 2 onstatus, heating on status, clogged filter status or unit shutdown status, <strong>an</strong>ddischarge air temperature. The Novar electronic thermostat module will have theability to enable the unit mounted economizer.Novar Return Air Sensor – This option, when used in conjunction with NovarControls, will contain a factory provided wired zone temperature sensor located inthe return air stream.Two Inch Pleated Filters – Two inch pleated media filters shall be available onall 12½-20 ton models.FIOPS-1 Effective 1/1/06


Downflow/Horizontal Packaged Cooling,Packaged Gas/Electric/Packaged HeatPump Factory Installed Options (FIOPS)Table FIOPS-2-A — AccessoriesModelNumber Description Used WithBlack Epoxy Coated Condenser CoilFIYCOIL205A Black Epoxy Coated Condenser Coil T/Y/WC*150FIYCOIL206A Black Epoxy Coated Condenser Coil T/YC*151,180,210FIYCOIL207A Black Epoxy Coated Condenser Coil WC*180FIYCOIL209A Black Epoxy Coated Condenser Coil T/YC*181,211,240,241,301, WC*240FIYCOIL210A Black Epoxy Coated Condenser Coil T/YC*300Circuit BreakerMust be used with Through-the-Base Electrical option (downflow only).FIYUCB3175A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB3200A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB3225A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB3250A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4015A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4020A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4025A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4030A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4035A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4040A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4045A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4050A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4060A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4070A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4080A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4090A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4100A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4110A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4125A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4150A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB6110A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB6125A Unit Mounted Circuit Breaker Consult Matrix SheetsConvenience OutletMust be ordered with Through-the-Base Electrical option <strong>an</strong>d either Unit Mounted Disconnect or Circuit Breaker (downflow only).FIYCOPO201A Powered, 120V Convenience Outlet, 230V TC/YCD150-301*3, WCD150-240*3FIYCOPO202A Powered, 120V Convenience Outlet, 230V TC/YCD150-301*4, WCD150-240*4FIYCOPO205A Powered, 120V Convenience Outlet, 230V TC/YCD150-301*W, WCD150-240*WFIYCOUP201A Unpowered, 115V Convenience Outlet TC/YCD150-301, WCD150-240Discharge Air Sensing KitUsed for true discharge air sensing in heating models. Functional only with ReliaTel TM Options Module (FIYABRD002B).FIYTUBE008A Discharge Air Sensing Kit (All Voltages) TC/YCD150-301*, WCD150-240FIYTUBE009A Discharge Air Sensing Kit (All Voltages) TC/YCH150-301*, WCH150-240Disconnect SwitchMust be used with Through-the-Base Electrical option (downflow only). C<strong>an</strong>not be fused.FIYUDC3250A Unit Mounted Disconnect Switch Consult Matrix SheetsFIYUDC4100A Unit Mounted Disconnect Switch Consult Matrix SheetsFIYUDC4150A Unit Mounted Disconnect Switch Consult Matrix SheetsFIYUDC6100A Unit Mounted Disconnect Switch Consult Matrix SheetsEconomizer Actuator Logic ModuleFIYLGCM001A is required when ordering the following Factory Installed Options (FIOPs). Reference Enthalpy (FIYENTH007A), ComparativeEnthalpy (FIYENTH008A), Novar Controls (FIYCNTL013A, 015A,016A, 017A,018A, 019A).FIYLGCM001A Economizer Actuator Logic Module All Voyager units with economizers <strong>an</strong>d theabove mentioned FIOPs. (FIOP #s)Effective 1/1/06FIOPS-2


Downflow/Horizontal PackagedCooling,Packaged Gas/Electric/Packaged HeatPump Factory Installed Options (FIOPS)Table FIOPS-3-A — AccessoriesModelNumber Description Used WithElectric Heat - CoolingMust be factory installed when using with Through-the-Base Electrical option.FIDHTRA309B Factory Installed 9 KW Electric Heat See Unit Price SheetsFIDHTRA318B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRA327B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIDHTRA336B Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRD318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRD336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRD354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRF318A Factory Installed 18 KW Electric Heat See Unit Price SheetFIDHTRK336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRK354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRL336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRL354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRK372A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIDHTRJ318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRJ336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRA409B Factory Installed 9 KW Electric Heat See Unit Price SheetsFIDHTRA418B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRA427B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIDHTRA436B Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRC418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRD436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRD454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRL418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRK436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRK454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRL436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRL454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRK472A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIDHTRJ418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRJ436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRAW18B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRAW27B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIDHTRCW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRCW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRCW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRKW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRKW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRMW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRLW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRKW72A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIDHTRJW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRJW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRA309B Factory Installed 9 KW Electric Heat See Unit Price SheetsFIHHTRA318B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRA327B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIHHTRA336B Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRD318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRD336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRD354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRM318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRM336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRM354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRN336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRN354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIOPS-3 Effective 1/1/06


Downflow/Horizontal Packaged Cooling,Packaged Gas/Electric/Packaged HeatPump Factory Installed Options (FIOPS)Table FIOPS-4-A — AccessoriesModelNumber Description Used WithElectric Heat - Cooling (Contd.)FIHHTRN372A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIHHTRJ318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRJ336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRA409B Factory Installed 9 KW Electric Heat See Unit Price SheetsFIHHTRA418B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRA427B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIHHTRA436B Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRM418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRM436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRM454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRN436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRN454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRN472A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIHHTRJ418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRJ436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRAW18B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRAW27B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIHHTRMW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRMW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRMW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRNW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRNW72A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIHHTRJW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRJW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRN318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRN418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRNW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRP336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRQ336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRP436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRQ436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRPW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRP354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRQ354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRP454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRQ454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRPW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRQW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIYHTRP105A Factory Installed 6 KW Electric Heat See Unit Price SheetsFIYHTRP110A Factory Installed 10 KW Electric Heat See Unit Price SheetsFIYHTRP114A Factory Installed 14 KW Electric Heat See Unit Price SheetsFIYHTRP118A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIYHTRP306A Factory Installed 6 KW Electric Heat See Unit Price SheetsFIYHTRP312A Factory Installed 12 KW Electric Heat See Unit Price SheetsFIYHTRP318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIYHTRP323A Factory Installed 23 KW Electric Heat See Unit Price SheetsFIYHTRP406A Factory Installed 6 KW Electric Heat See Unit Price SheetsFIYHTRP412A Factory Installed 12 KW Electric Heat See Unit Price SheetsFIYHTRP418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIYHTRP423A Factory Installed 23 KW Electric Heat See Unit Price SheetsFIYHTRPW06A Factory Installed 6 KW Electric Heat See Unit Price SheetsFIYHTRPW12A Factory Installed 12 KW Electric Heat See Unit Price SheetsFIYHTRPW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIYHTRPW23A Factory Installed 23 KW Electric Heat See Unit Price SheetsEffective 1/1/06FIOPS-4


Downflow/Horizontal PackagedCooling,Packaged Gas/Electric/Packaged HeatPump Factory Installed Options (FIOPS)Table FIOPS-5-A — AccessoriesModelNumber Description Used WithElectric Heat - Heat PumpMust be factory installed when using with Through-the-Base Electrical option.FIYHTRP105A Factory Installed 6 KW Electric Heat See Unit Price SheetsFIYHTRP110A Factory Installed 10 KW Electric Heat See Unit Price SheetsFIYHTRP114A Factory Installed 14 KW Electric Heat See Unit Price SheetsFIYHTRP118A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIYHTRP306A Factory Installed 6 KW Electric Heat See Unit Price SheetsFIYHTRP312A Factory Installed 12 KW Electric Heat See Unit Price SheetsFIYHTRP318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIYHTRP323A Factory Installed 23 KW Electric Heat See Unit Price SheetsFIYHTRP406A Factory Installed 6 KW Electric Heat See Unit Price SheetsFIYHTRP412A Factory Installed 12 KW Electric Heat See Unit Price SheetsFIYHTRP418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIYHTRP423A Factory Installed 23 KW Electric Heat See Unit Price SheetsFIYHTRPW06A Factory Installed 6 KW Electric Heat See Unit Price SheetsFIYHTRPW12A Factory Installed 12 KW Electric Heat See Unit Price SheetsFIYHTRPW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIYHTRPW23A Factory Installed 23 KW Electric Heat See Unit Price SheetsFIDHTRA327B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIDHTRA336B Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRB309B Factory Installed 9 KW Electric Heat See Unit Price SheetsFIDHTRB318B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRD318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRD336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRD354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRK318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRK336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRK354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRL336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRL354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRK372A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIDHTRA409B Factory Installed 9 KW Electric Heat See Unit Price SheetsFIDHTRA418B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRA427B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIDHTRA436B Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRC418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRD418A Factory Installed 9 KW Electric Heat See Unit Price SheetsFIDHTRD436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRD454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRK436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRK454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRL436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRL454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRK472A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIDHTRAW18B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRAW27B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIDHTRCW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRCW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRCW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRDW18A Factory installed 18 KW Electric Heat See Unit Price SheetsFIOPS-5 Effective 1/1/06


Downflow/Horizontal PackagedCooling,Packaged Gas/Electric/Packaged HeatPump Factory Installed Options (FIOPS)Table FIOPS-6-A — AccessoriesModelNumber Description Used WithElectric Heat - Heat Pump (Contd.)FIDHTRDW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRKW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRKW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRLW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRMW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRKW72A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIHHTRA327B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIHHTRA336B Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRB309B Factory Installed 9 KW Electric Heat See Unit Price SheetsFIHHTRB318B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRD318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRD336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRD354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRM318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRM336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRM354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRN336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRN354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRN372A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIHHTRA409B Factory Installed 9 KW Electric Heat See Unit Price SheetsFIHHTRA418B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRA427B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIHHTRA436B Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRM418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRD418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRM436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRM454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRN436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRN454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRN472A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIHHTRAW18B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRAW27B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIHHTRMW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRMW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRCW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTREW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRMW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRNW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRNW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRNW72A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIHHTRMW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRNW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRNW72A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIHHTRN318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRNW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRP336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRP436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRP454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRQW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRP418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRQW36A Factory Installed 18 KW Electric Heat See Unit Price SheetsEffective 1/1/06FIOPS-6


Downflow/Horizontal Packaged Cooling,Packaged Gas/Electric/Packaged HeatPump Factory Installed Options (FIOPS)Table FIOPS-7-A — AccessoriesModelNumber Description Used WithEnthalpy KitsFIYENTH007A Reference Enthalpy Downflow Units w/A,C or G in 10th DigitFIYENTH008A Comparative Enthalpy Downflow Units w/A,C or G in 10th DigitFilter & Control Access(Downflow units only)FIYHNGE004A Hinged Filter/Evap. <strong>an</strong>d Comp./Control Access Door TC/YCD150,180,210, WCD150-180FIYHNGE005A Hinged Filter/Evap. <strong>an</strong>d Comp./Control Access Door TC/YCD300FIYHNGE008A Hinged Filter/Evap. <strong>an</strong>d Comp./Control Access Door TC/YCD151FIYHNGE009A Hinged Filter/Evap. <strong>an</strong>d Comp./Control Access Door TC/YCD181,211,240,241,301, WCD240FrostatFIYLOAM023A Frostat TC/YCD151,181,241 with H,J,K,L in 10th digitw/FIYABRD002BHigh Efficiency MotorsC<strong>an</strong> be used on downflow or horizontal units unless specified on matrix sheets.FIYHEMT001A2 HP High Effic. Motor (86.5 Eff.)(208-230/460/60/3) Consult Matrix SheetsFIYHEMT002A 2 HP High Effic. Motor (86.5 Eff.)(575/60/3) Consult Matrix SheetsFIYHEMT003A 3 HP High Effic. Motor (89.5 Eff.)(208-230/60/3) Consult Matrix SheetsFIYHEMT004A 3 HP High Effic. Motor (89.5 Eff.)(460/60/3) Consult Matrix SheetsFIYHEMT005A 3 HP High Effic. Motor (89.5 Eff.)(575/60/3) Consult Matrix SheetsFIYHEMT006A 5 HP High Effic. Motor (91.0 Eff.)(208-230/60/3) Consult Matrix SheetsFIYHEMT007A 5 HP High Effic. Motor (91.0 Eff.)(460/60/3) Consult Matrix SheetsFIYHEMT008A 5 HP High Effic. Motor (91.0 Eff.)(575/60/3) Consult Matrix SheetsFIYHEMT009A 7½ HP High Effic. Motor (90.2 Eff.)(208-230/60/3) Consult Matrix SheetsFIYHEMT010A 7½ HP High Effic. Motor (90.2 Eff.)(460/60/3) Consult Matrix SheetsFIYHEMT011A 7½ HP High Effic. Motor (90.2 Eff.)(575/60/3) Consult Matrix SheetsLCIFIYLTCI003B Comm-5 LonTalk Interface TC/YC*150-301, WC*150-240Novar Controls-2024The Novar control option includes the following factory installed <strong>an</strong>d wired devices: Novar ETM-2024 rooftop controller, f<strong>an</strong> proving switch, cloggedfilter or unit shutdown switch, Cool 1,Cool 2, Heat switch <strong>an</strong>d discharge air sensor (downflow only) (Novar # DTS-30, 20-170°F). NOTE: Optionc<strong>an</strong>not be ordered in conjunction with FIOPS Smoke Detector option.FIYCNTL013A Novar Control, 208-230V T/YCD150-301*3FIYCNTL015A Novar Control, 460 & 575V T/ YCD150-301*4,WNovar Controls-3051The Novar control option includes the following factory installed <strong>an</strong>d wired devices: Novar 3051 rooftop controller, f<strong>an</strong> proving switch, clogged filter orunit shutdown switch, <strong>an</strong>d discharge air sensor (Novar # DTS-30, 20-170°F) (downflow only). NOTE: This option c<strong>an</strong> be ordered in conjunction withfactory installed Smoke Detector option. It c<strong>an</strong> also be ordered with 100% DB economizer but not with enthalpy controls.FIYCNTL016A Novar Control, 460V, 575V TC/ YCD181,211,240,241,300,301*4,WFIYCNTL017A Novar Control, 208-230V TC/ YCD150,151,180,210*3FIYCNTL018A Novar Control, 460V, 575V TC/YCD150,151,180,210*4,WFIYCNTL019A Novar Control, 208-230V TC/YCD181,211,240,241,300,301*3Novar Return Air SensorThis option consists of the Novar return air sensor (Novar # WTS-10) that is wired <strong>an</strong>d shipped in the return air section of the unit. The sensorships with approximately 15' of extra wire for dropping down the return air duct (downflow only).FIYNRAS001A Return Air Sensor FIYCNTL013A <strong>an</strong>d FIYCNTL015ANovar Zone SensorThis option consists of a Novar Zone Sensor (Novar #WTS-SOS) used with Novar 3051 Controls.FIYNZSR001A Novar Zone Sensor for Novar 3051 FIYCNTL016AReliaTel TM Options ModuleFIYABRD002B is required when ordering the following accessories: Clogged Filter Switch (FIYDFPS005A/BAYDFPS005A), F<strong>an</strong> Fail Switch (FIYDFPS006A/BAYDFPS006A), Discharge Air Sensing Kit (FIYTUBE008A,FIYTUBE009A, BAYTUBE008A, BAYTUBE009A), Frostat (FIYLOAM023A, BAYLOAM023A),Ventilation Override (must order BAYVNOR002B), Smoke Detector (FIYSMDT).FIYABRD002B ReliaTel TM Options Module All Voyager UnitsFIOPS-7 Effective 1/1/06


Downflow/Horizontal PackagedCooling,Packaged Gas/Electric/Packaged HeatPump Factory Installed Options (FIOPS)Table FIOPS-8-A — AccessoriesModelNumber Description Used WithSmoke Detector (Return Air) for downflow units with economizer123Option c<strong>an</strong>not be ordered in conjunction with field installed economizer.FIYSMDT221A Return Air Smoke Detector TC/YCD150,151,180,210, WCD150,180FIYSMDT223A Return Air Smoke Detector TC/YCD181,211,240,241,300,301, WCD240Smoke Detector (Return Air) for downflow units without economizer123FIYSMDT222A Return Air Smoke Detector TC/YCD150,151,180,210, WCD150,180FIYSMDT224A Return Air Smoke Detector TC/YCD181,211,240,241,300,301, WCD240Smoke Detector (Supply Air) for downflow units 23FIYSMDT225A Supply Air Smoke Detector TC/ YCD150,151,180,210, WCD150B-180FIYSMDT228A Supply Air Smoke Detector TC/ YCD181,211,240,241,300,301, WCD240Smoke Detectors (Supply <strong>an</strong>d Return Air) for downflow units with economizer123Option c<strong>an</strong>not be ordered in conjunction with field installed economizer.FIYSMDT226A Supply <strong>an</strong>d Return Air Smoke Detector TC/ YCD150,151,180,210, WCD150,180FIYSMDT229A Supply <strong>an</strong>d Return Air Smoke Detector TC/YCD181,211,240,241,300,301, WCD240Smoke Detectors (Supply <strong>an</strong>d Return Air ) for downflow units without economizer123FIYSMDT227A Supply <strong>an</strong>d Return Air Smoke Detector TC/ YCD150,151,180,210, WCD150,180BFIYSMDT230A Supply <strong>an</strong>d Return Air Smoke Detector TC/YCD181,211,240,241,300,301, WCD240B1 The return air smoke detector may not fit up or work properly on the Voyager units when used in conjunction with 3rd party accessories (such as bolt onheat wheels, economizers, <strong>an</strong>d power exhaust). Do not order the return air smoke detectors when using this type of accessory.2 Smoke Detectors available for downflow units only.3 Functional only with ReliaTel Options Module (FIYABR002B).Stainless Steel Heat Exch<strong>an</strong>gerFIYSSHX001A 150 MBH Stainless Steel Heat Exch<strong>an</strong>ger YC*150,151 Low HeatFIYSSHX002A 250 MBH Stainless Steel Heat Exch<strong>an</strong>ger YC*150,151 High HeatYC*155,175,180,181,200,210,211,240,241,250,300 <strong>an</strong>d301 Low HeatFIYSSHX003A 350 MBH Stainless Steel Heat Exch<strong>an</strong>ger YC*155,175,180,181,210,211 High HeatFIYSSHX004A 400 MBH Stainless Steel Heat Exch<strong>an</strong>ger YC*200,240,241,250,300,301 High HeatSwitches1FIYDFPS005A Clogged Filter Switch All Voyager UnitsFIYDFPS006A F<strong>an</strong> Failure Switch All Voyager Units1 Functional only with ReliaTel Options Module (FIYABR002B).TCIFIYICSI004B <strong>Tr<strong>an</strong>e</strong> Communication Interface All Units w/B or C in 10th Digit <strong>an</strong>d- when combination of oversize TXV Units w/H, J, K or L in 10th Digitmotor <strong>an</strong>d TCI is required.Effective 1/1/06FIOPS-8


Downflow/Horizontal Packaged Cooling,Packaged Gas/Electric/Packaged HeatPump Factory Installed Options (FIOPS)Table FIOPS-9-A — AccessoriesModelNumber Description Used WithThrough the Base ElectricalMust be used with Unit Mounted Disconnect Switch or Unit Mounted Circuit Breaker (downflow only). When adding heat, must order <strong>Tr<strong>an</strong>e</strong> Electric Heat. If no factory installed UnitMounted disconnect Switch or Unit Mounted Circuit Breaker is required, order the Through the Base Utility Access Option (FIYTBUA****)FIYTBUE206A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE207A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE208A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE209A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE210A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE211A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE212A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE213A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE214A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE215A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE216A Through-the-Base Electrical Option Consult Matrix SheetsThrough The Base Gas PipingFIYTBUG202A1 Through-the-Base Gas Piping YCD150,151 Low & High HeatYCD180-301 Low HeatFIYTBUG203A1 Through-the-Base Gas Piping YCD180-301 High HeatFIYTBUG205A2 Through-the-Base Gas Piping YCD150,151 Low & High HeatYCD180-301 Low HeatFIYTBUG206A2 Through-the-Base Gas Piping YCD180-301 High Heat1 Must order when ordering through-the-base electrical or through-the-base access option (downflow only).2 Order when not ordering through-the-base electrical or through-the-base access option (downflow only).Through the Base Utilities AccessOrder this accessory when no factory installed Unit Mounted Disconnect Switch or Unit Mounted Circuit Breaker is required. If factory installed Unit MountedDisconnect or Unit Mounted Circuit Breaker is required, order the Through the Base Electrical Option (FIYTBUE****) from the FIOP Matrix page.FIYTBUA204A Through the Base Utilities Access YCD150,151,180,210FIYTBUA205A Through the Base Utilities Access TCD150,151,180,210, WCD150,180FIYTBUA206A Through the Base Utilities Access YCD181,211,240,241,300,301FIYTBUA207A Through the Base Utilities Access TCD181,211,240,241,300,301, WCD240,300Tool-less Condenser Hail GuardFIYGARD001B Tool-less Condenser Hail Guard TC/YC*150, WC*150FIYGARD002B Tool-less Condenser Hail Guard TC/YC*151,180,210, WC*180FIYGARD003A Tool-less Condenser Hail Guard TC/YC*181,211,240,241,301,WC*240FIYGARD005A Tool-less Condenser Hail Guard TC/YC*3002" Pleated FiltersFIYPLTD001A 2" Pleated Filters TC/YC*150,151,180,210, WC*150,180FIYPLTD002A 2" Pleated Filters TC/YCD181,211,240,241,300,301, WCD240FIYPLTD003A 2" Pleated Filters TC/YCH181,211,240,241,300,301, WCH240FIOPS-9 Effective 1/1/06


Downflow Packaged Cooling, & Gas ElectricFactory Installed Options (FIOPS)Matrix PageHigh Efficiency Through-the-Base Electrical Unit Mounted Disconnect Unit Mounted Circuit BreakerModel Motors FIYTBUE___A (3) FIYUDC____A (2) FIYUCB____A (2)Number (1)(4) FIYHEMT___A (5) (Downflow Only) (Downflow Only) (Downflow Only)CO* (*=0) Cooling & CO* & CO* &GE* (* = L or H Heat) Gas Electric CO*/GE* 18KW 27KW 36KW 54KW 72KW GE* 18KW 27KW 36KW 54KW 72KW GE* 18KW 27KW 36KW 54KW 72KWT/YFD150D3*0B 003 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4080 4080 N/A 6125 3200 N/AT/YFD150D3*BB 006 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4080 4080 N/A 4150 3200 N/AT/YFD150D4*0B 004 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4070 4090 N/AT/YFD150D4*BB 007 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4070 4100 N/AT/YFD150DW*0B 005 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4030 4030 N/A 4050 4070 N/AT/YFD150DW*BB 008 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4035 4035 N/A 4060 4080 N/AT/YFD151C3*0B 003 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4080 4080 N/A 6125 3200 N/AT/YFD151C3*BB 006 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4090 4090 N/A 4150 3200 N/AT/YFD151C4*0B 004 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4070 4090 N/AT/YFD151C4*BB 007 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4070 4100 N/AT/YFD151CW*0B 005 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4030 4030 N/A 4050 4070 N/AT/YFD151CW*BB 008 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4035 4035 N/A 4060 4080 N/AT/YFD151C3*HB 003 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4070 4070 N/A 6125 3200 N/AT/YFD151C3*JB 006 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4080 4080 N/A 4150 3200 N/AT/YFD151C4*HB 004 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4035 4035 N/A 4070 4090 N/AT/YFD151C4*JB 007 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4070 4100 N/AT/YFD151CW*HB 005 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4030 4030 N/A 4050 4070 N/AT/YFD151CW*JB 008 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4030 4030 N/A 4060 4080 N/AT/YFD180B3*0H 003 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4090 4100 N/A 6125 3200 N/AT/YFD180B3*BH 006 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4100 4100 N/A 4150 3200 N/AT/YFD180B4*0H 004 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4050 4050 N/A 4070 4090 N/AT/YFD180B4*BH 007 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4050 4050 N/A 4070 4100 N/AT/YFD180BW*0H 005 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4050 4070 N/AT/YFD180BW*BH 008 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4060 4080 N/AT/YFD181C3*0C 003 213/212 214 N/A 215 216 N/A 6100 6100 N/A 4150 3250 N/A 4090 4100 N/A 6125 3200 N/AT/YFD181C3*BC 006 213/212 214 N/A 215 216 N/A 6100 6100 N/A 4150 3250 N/A 4100 4100 N/A 4150 3200 N/AT/YFD181C4*0C 004 213/211 214 214 214 214 N/A 6100 6100 6100 6100 6100 N/A 4050 4050 4050 4070 4090 N/AT/YFD181C4*BC 007 213/211 214 N/A 214 214 N/A 6100 6100 N/A 6100 6100 N/A 4050 4050 N/A 4070 4100 N/AT/YFD181CW*0C 005 213/211 214 N/A 214 214 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4050 4070 N/AT/YFD181CW*BC 008 213/211 214 N/A 214 214 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4060 4080 N/AT/YFD181C3*HC 003 213/212 214 N/A 215 216 N/A 6100 6100 N/A 4150 3250 N/A 4090 4100 N/A 6125 3200 N/AT/YFD181C3*JC 006 213/212 214 N/A 215 216 N/A 6100 6100 N/A 4150 3250 N/A 4090 4090 N/A 4150 3200 N/AT/YFD181C4*HC 004 213/211 214 214 214 214 N/A 6100 6100 6100 6100 6100 N/A 4050 4050 4050 4070 4090 N/AT/YFD181C4*JC 007 213/211 214 N/A 214 214 N/A 6100 6100 N/A 6100 6100 N/A 4050 4050 N/A 4070 4100 N/AT/YFD181CW*HC 005 213/211 214 N/A 214 214 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4050 4070 N/AT/YFD181CW*JC 008 213/211 214 N/A 214 214 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4060 4080 N/AFACTORY INSTALLED OPTIONS (FIOPS)(1) Unit model # ch<strong>an</strong>ges to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect st<strong>an</strong>dard model #, i.e. T/YCD).(2) Unit mounted disconnect <strong>an</strong>d circuit breakers are mutually exclusive of each other.(3) Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order <strong>Tr<strong>an</strong>e</strong> Electric Heat.(4) When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer <strong>an</strong>d TCI ("G" in 10th digit) use line with model number with "0" in 10th digit forFIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10thdigit for FIOP selections. When ordering thermal exp<strong>an</strong>sion valve ("H" in 10th digit) with economizer ("L" in 10th digit) use line with model number with "H" in the 10thALL FACTORY INSTALLEDOPTIONS ARE BUILT-TO-ORDER.CHECK ORDER SERVICES FORESTIMATED PRODUCTION CYCLE.digit for FIOP selections; when ordering thermal exp<strong>an</strong>sion valve with oversized motor ("J" in 10th digit) or oversized motor & economizer ("K" in 10th digit) uses line with model number with "J" in 10th digit for FIOP selections.(5) High efficiency motors c<strong>an</strong> be factory installed on downflow <strong>an</strong>d horizontal units unless noted. When ordering horizontal units with high efficiency motors,unit model # ch<strong>an</strong>ges to "H" in 3rd digit.CO* = Cooling Only GE* = Gas ElectricEffective 1/1/06FIOPS-10


Downflow Packaged Cooling, & Gas ElectricFactory Installed Options (FIOPS)Matrix Page (Contd.)High Efficiency Through-the-Base Electrical Unit Mounted Disconnect Unit Mounted Circuit BreakerModel Motors FIYTBUE___A (3) FIYUDC____A (2) FIYUCB____A (2)Number (1)(4) FIYHEMT___A (5) (Downflow Only) (Downflow Only) (Downflow Only)CO* (*=0) Cooling & CO* &GE* = (*= L or H Heat) Gas Electric CO*/GE* 18KW 27KW 36KW 54KW 72KW GE* 18KW 27KW 36KW 54KW 72KW CO*/GE* 18KW 27KW 36KW 54KW 72KWT/YFD210C3*0E 006 207/206 N/A N/A 209 210 N/A 6100 N/A N/A 4150 3250 N/A 4100/4100 N/A N/A 4150 3200 N/AT/YFD210C3*BE 009 207/206 N/A N/A 209 210 N/A 4150 N/A N/A 4150 3250 N/A 6125/4125 N/A N/A 4150 3200 N/AT/YFD210C4*0E 007 207/206 N/A N/A 208 208 N/A 6100 N/A N/A 6100 6100 N/A 4050/4050 N/A N/A 4070 4100 N/AT/YFD210C4*BE 010 207/206 N/A N/A 208 208 N/A 6100 N/A N/A 6100 6100 N/A 4060/4060 N/A N/A 4070 4100 N/AT/YFD210CW*0E 008 207/206 N/A N/A 208 208 N/A 6100 N/A N/A 6100 6100 N/A 4045/4045 N/A N/A 4060 4080 N/AT/YFD210CW*BE 011 207/206 N/A N/A 208 208 N/A 6100 N/A N/A 6100 6100 N/A 4045/4045 N/A N/A 4060 4080 N/AT/YFD211C3*0C 006 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6110/4110 N/A N/A 4150 3200 3250T/YFD211C3*BC 009 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250T/YFD211C4*0C 007 213/211 N/A 214 214 214 215 6100 N/A 6100 6100 6100 4150 4060/4060 N/A 4060 4070 4100 6125T/YFD211C4*BC 010 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 4150 4060/4060 N/A N/A 4070 4100 6125T/YFD211CW*0C 008 213/211 N/A N/A 214 214 214 6100 N/A N/A 6100 6100 6100 4045/4045 N/A N/A 4060 4080 4100T/YFD211CW*BC 011 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 6100 4050/4050 N/A N/A 4060 4080 4100T/YFD240B3*0J 006 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250T/YFD240B3*BJ 009 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250T/YFD240B4*0J 007 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 4150 4060/4060 N/A N/A 4070 4100 6125T/YFD240B4*BJ 010 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 4150 4060/4060 N/A N/A 4070 4100 6125T/YFD240BW*0J 008 213/211 N/A N/A 214 214 214 6100 N/A N/A 6100 6100 6100 4045/4045 N/A N/A 4060 4080 4100T/YFD240BW*BJ 011 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 6100 4050/4050 N/A N/A 4060 4080 4100T/YFD241C3*0C 006 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250T/YFD241C3*BC 009 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250T/YFD241C4*0C 007 213/211 N/A 214 214 214 215 6100 N/A 6100 6100 6100 4150 4060/4060 N/A 4060 4070 4100 6125T/YFD241C4*BC 010 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 4150 4060/4060 N/A N/A 4070 4100 6125T/YFD241CW*0C 008 213/211 N/A N/A 214 214 214 6100 N/A N/A 6100 6100 6100 4050/4050 N/A N/A 4060 4080 4100TFD241CW*BC 011 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 6100 4050/4050 N/A N/A 4060 4080 4100T/YFD241C3*HC 006 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250T/YFD241C3*JC 009 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250T/YFD241C4*HC 007 213/211 N/A 214 214 214 215 6100 N/A 6100 6100 6100 4150 4060/4060 N/A 4060 4070 4100 6125T/YFD241C4*JC 010 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 4150 4070/4070 N/A N/A 4070 4100 6125T/YFD241CW*HC 008 213/211 N/A N/A 214 214 214 6100 N/A N/A 6100 6100 6100 4050/4050 N/A N/A 4060 4080 4100T/YFD241CW*JC 011 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 6100 4050/4050 N/A N/A 4060 4080 4100FACTORY INSTALLED OPTIONS (FIOPS)(1) Unit model # ch<strong>an</strong>ges to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect st<strong>an</strong>dard model #, i.e. T/YCD).(2) Unit mounted disconnect <strong>an</strong>d circuit breakers are mutually exclusive of each other.(3) Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order <strong>Tr<strong>an</strong>e</strong> Electric Heat.(4) When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer <strong>an</strong>d TCI ("G" in 10th digit) use line with model number with "0" in 10th digit forFIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10thdigit for FIOP selections. When ordering thermal exp<strong>an</strong>sion valve ("H" in 10th digit) with economizer ("L" in 10th digit) use line with model number with "H" in the 10thdigit for FIOP selections; when ordering thermal exp<strong>an</strong>sion valve with oversized motor ("J" in 10th digit) or oversized motor & economizer ("K" in 10th digit) uses line withmodel number with "J" in 10th digit for FIOP selections.(5) High efficiency motors c<strong>an</strong> be factory installed on downflow <strong>an</strong>d horizontal units unless noted. When ordering horizontal units with high efficiency motors,unit model # ch<strong>an</strong>ges to "H" in 3rd digit.CO* = Cooling Only GE* = Gas ElectricALL FACTORY INSTALLEDOPTIONS ARE BUILT-TO-ORDER.CHECK ORDER SERVICES FORESTIMATED PRODUCTION CYCLE.FIOPS-11 Effective 1/1/06


Downflow Packaged Cooling, & Gas ElectricFactory Installed Options (FIOPS)Matrix Page (Contd.)High Efficiency Through-the-Base Electrical Unit Mounted Disconnect Unit Mounted Circuit BreakerModel Motors FIYTBUE___A (3) FIYUDC____A (2) FIYUCB____A (2)Number (1)(4) FIYHEMT___A (5) (Downflow Only) (Downflow Only) (Downflow Only)CO* (* = 0) Cooling & CO* & CO* &GE* = (L or H Heat) Gas Electric CO*/GE* 18KW 27KW 36KW 54KW 72KW GE* 18KW 27KW 36KW 54KW 72KW GE* 18KW 27KW 36KW 54KW 72KWT/YFD300B3*0H 009 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 4150 N/A N/A 4150 3200 3250T/YFD300B4*0H 010 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 4150 4070 N/A N/A 4070 4100 6125T/YFD300BW*0H 011 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 6100 4050 N/A N/A 4060 4080 4100T/YFD301C3*0C 009 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 4150 N/A N/A 4150 3200 3250T/YFD301C4*0C 010 213/211 N/A 214 214 214 215 6100 N/A 6100 6100 6100 4150 4070 N/A 4070 4070 4100 6125T/YFD301CW*0C 011 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 6100 4060 N/A N/A 4060 4080 4100FACTORY INSTALLED OPTIONS (FIOPS)(1) Unit model # ch<strong>an</strong>ges to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect st<strong>an</strong>dard model #, i.e. T/YCD).(2) Unit mounted disconnect <strong>an</strong>d circuit breakers are mutually exclusive of each other.(3) Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order <strong>Tr<strong>an</strong>e</strong> Electric Heat.(4) When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer <strong>an</strong>d TCI ("G" in 10th digit) use line with model number with "0" in 10th digit forFIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10thdigit for FIOP selections. When ordering thermal exp<strong>an</strong>sion valve ("H" in 10th digit) with economizer ("L" in 10th digit) use line with model number with "H" in the 10thdigit for FIOP selections; when ordering thermal exp<strong>an</strong>sion valve with oversized motor ("J" in 10th digit) or oversized motor & economizer ("K" in 10th digit) uses line withmodel number with "J" in 10th digit for FIOP selections.(5) High efficiency motors c<strong>an</strong> be factory installed on downflow <strong>an</strong>d horizontal units unless noted. When ordering horizontal units with high efficiency motors,unit model # ch<strong>an</strong>ges to "H" in 3rd digit.CO* = Cooling OnlyGE* = Gas ElectricALL FACTORY INSTALLED OPTIONS ARE BUILT-TO-ORDER.CHECK ORDER SERVICES FOR ESTIMATED PRODUCTION CYCLE.Effective 1/1/06FIOPS-12


Downflow Packaged Heat PumpFactory Installed Options (FIOPS)Matrix PageHigh Efficiency Through-the-Base Electrical Unit Mounted Disconnect Unit Mounted Circuit BreakerModel Motors FIYTBUE___A (3) FIYUDC____A (2) FIYUCB____A (2)Number (1) FIYHEMT___A (5) (Downflow Only) (Downflow Only) (Downflow Only)withoutaux. heatCO* 18KW 36KW 54KW 72KW CO* 18KW 36KW 54KW 72KW CO* 18KW 36KW 54KW 72KWWFD150B300G 003 207 209 210 210 N/A 6100 4150 3250 3250 N/A 4080 6125 3175 3250 N/AWFD150B30BG 006 207 209 210 210 N/A 6100 4150 3250 3250 N/A 4080 4150 3200 3250 N/AWFD150B400G 004 207 208 208 209 N/A 6100 6100 6100 4150 N/A 4040 4060 4090 6125 N/AWFD150B40BG 007 207 208 208 209 N/A 6100 6100 6100 4150 N/A 4040 4070 4090 6125 N/AWFD150BW00G 005 207 208 208 208 N/A 6100 6100 6100 6100 N/A 4030 4050 4070 4090 N/AWFD150BW0BG 008 207 208 208 208 N/A 6100 6100 6100 6100 N/A 4035 4050 4080 4100 N/Awithoutaux. heatwithoutaux. heatFACTORY INSTALLED OPTIONS (FIOPS)(1) Unit model # ch<strong>an</strong>ges to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect st<strong>an</strong>dard model #, i.e. WCD).(2) Unit mounted disconnect <strong>an</strong>d circuit breakers are mutually exclusive of each other.(3) Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order <strong>Tr<strong>an</strong>e</strong> Electric Heat.(4) When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer <strong>an</strong>d TCI ("G" in 10th digit) use line with model number with "0" in 10th digit forFIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10thdigit for FIOP selections.(5) High efficiency motors c<strong>an</strong> be factory installed on downflow <strong>an</strong>d horizontal units unless noted. When ordering horizontal units with high efficiency motors,unit model # ch<strong>an</strong>ges to "H" in 3rd digit.* Cooling OnlyFIOPS-13 Effective 1/1/06


Downflow Packaged Heat PumpFactory Installed Options (FIOPS)Matrix Page (Contd.)High Efficiency Through-the-Base Electrical Unit Mounted Disconnect Unit Mounted Circuit BreakerModel Motors FIYTBUE___A (3) FIYUDC____A (2) FIYUCB____A (2)Number (1) FIYHEMT___A (5) (Downflow Only) (Downflow Only) (Downflow Only)withoutaux. heatCO* 18KW 36KW 54KW 72KW CO* 18KW 36KW 54KW 72KW CO* 18KW 36KW 54KW 72KWWFD180B300G 003 207 209 210 210 N/A 6100 4150 3250 3250 N/A 4090 4150 3200 3250 N/AWFD180B30BG 006 207 209 210 NA N/A 6100 4150 3250 3250 N/A 4100 4150 3200 3250 N/AWFD180B400G 004 207 208 208 209 N/A 6100 6100 6100 4150 N/A 4045 4070 4100 6125 N/AWFD180B40BG 007 207 208 209 209 N/A 6100 6100 6100 4150 N/A 4050 4070 4100 6125 N/AWFD180BW00G 005 207 208 208 209 N/A 6100 6100 6100 6100 N/A 4035 4060 4080 4100 N/AWFD180BW0BG 008 207 208 208 209 N/A 6100 6100 6100 6100 N/A 4040 4060 4080 4100 N/AWFD240B300G 006 213 N/A 216 216 N/A 4150 N/A 3250 NA N/A 6125 N/A 3225 NA N/AWFD240B30BG 009 213 N/A 216 NA N/A 4150 N/A 3250 NA N/A 6125 N/A 3225 NA N/AWFD240B400G 007 213 N/A 215 215 N/A 6100 N/A 4150 4150 N/A 4060 N/A 6110 4150 N/AWFD240B40BG 010 213 N/A 215 215 N/A 6100 N/A 4150 4150 N/A 4060 N/A 6110 4150 N/AWFD240BW00G 008 213 N/A 214 215 215 6100 N/A 6100 4150 4150 4045 N/A 4090 6110 6125WFD240BW0BG 011 213 N/A 214 215 215 6100 N/A 6100 4150 4150 4050 N/A 4090 6110 4150withoutaux. heatwithoutaux. heatFACTORY INSTALLED OPTIONS (FIOPS)(1) Unit model # ch<strong>an</strong>ges to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect st<strong>an</strong>dard model #, i.e. WCD).(2) Unit mounted disconnect <strong>an</strong>d circuit breakers are mutually exclusive of each other.(3) Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order <strong>Tr<strong>an</strong>e</strong> Electric Heat.(4) When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer <strong>an</strong>d TCI ("G" in 10th digit) use line with model number with "0" in 10th digit forFIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10thdigit for FIOP selections.(5) High efficiency motors c<strong>an</strong> be factory installed on downflow <strong>an</strong>d horizontal units unless noted. When ordering horizontal units with high efficiency motors,unit model # ch<strong>an</strong>ges to "H" in 3rd digit.* Cooling OnlyALL FACTORY INSTALLED OPTIONS ARE BUILT-TO-ORDER.CHECK ORDER SERVICES FOR ESTIMATED PRODUCTION CYCLE.Effective 1/1/06FIOPS-14


Comfort ControlDefinitionsCalibrationThe relationship of the dial setting <strong>an</strong>dthe cut-in temperature of thethermostat.ComfortLink TMAn open architecture communicationsbridge for reliably interfacing toautomation <strong>an</strong>d energy m<strong>an</strong>agementsystems.Cut-in PointThe temperature at which thethermostat calls for system operation.Cut-out PointThe temperature at which thethermostat stops calling forheating or cooling.Cycle RateThe number of times per hour that theheating equipment is cycled on athalf load conditions.DroopAn indoor temperature controlcondition where the room remainsbelow the thermostat setting. Thiscontrol occurs in mild coolingconditions <strong>an</strong>d is caused by thecooling <strong>an</strong>ticipator resistor whichprovides a false heat source: forthe thermostat to maintain relativehumidity control.Heat Anticipator(Sometimes called a PreheatResistor.)A bias heater that shuts off thethermostat before the roomreaches the thermostat setting.M<strong>an</strong>ual or Mech<strong>an</strong>icalDifferentialThe difference (Degrees F) betweencut-in <strong>an</strong>d cut-out temperature with noelectrical load connected to thethermostat.Operating DifferentialThe difference (Degrees F) incut-in <strong>an</strong>d cut-out temperature whenthe thermostat is actually operatingequipment. Operating differential isless th<strong>an</strong> mech<strong>an</strong>ical differential.R<strong>an</strong>geMinimum to maximum temperaturescale shown on dial.SensorA device that measures <strong>an</strong>dcommunicates temperature of theconditioned space in which it islocated to a system controller.Set PointThe temperature at which thethermostat indicator is set.Two Piece ThermostatSystem consisting of a sensormounted in the controlled spacecommunicating to a controller whichestablishes the systems operation.Power Stealing 4 WireResistor Terminal in Box. 4-wiresystem to supply power with heatingmode; steals power from "y" incooling.CCZO-1 Effective 1/1/06


Programmable 7 DayComfort ControlsTCONT800A• Interactive Touchscreen• Effortless Programming• Large, Backlit Display• Streamlined Design• Armchair Programming• Real Time Clock• Visual Reminder Cues• BAYCOVR600A - Wall cover plate• Energy StarApplication:• 1 Heat/1 Cool (Gas, Oil or Electric)• 1 Heat/0 Cool (Gas, Oil or Electric)• 0 Heat/1 Cool• ZZSENSAL0800AA - Remote IndoorTemperature SensorDimensions:• 6.02” w x 4.62” h• Finish: Bright WhiteTCONT802A• Interactive Touchscreen• Effortless Programming• Large, Backlit Display• Streamlined Design• Armchair Programming• Real Time Clock• Visual Reminder Cues• BAYCOVR600A - Wall cover plate• Energy StarTCONT803A• Built-in Humidity Sensor• Dehumidification Control• Interactive Touchscreen• Effortless Programming• Large, Backlit Display• Streamlined Design• Armchair Programming• Real Time Clock• Visual Reminder Cues• BAYCOVR600A - Wall cover plate• Energy StarApplication:• Up to 3 Heat/2 Cool(Gas, Oil or Electric)/HP• ZZSENSAL0800AA - Remote IndoorTemperature SensorDimensions:• 6.02” w x 4.62” h• Finish: Bright WhiteApplication:• Up to 3 Heat/2 Cool(Gas, Oil or Electric)/HP• ZZSENSAL0800AA - Remote IndoorTemperature SensorDimensions:• 6.02” w x 4.62” h• Finish: Bright WhiteBAYCOVR600AApplication:• Use with TCONT800A Series ComfortControls• Finish: Bright WhiteEffective 1/1/06CCZO-2


Programmable 7 DayComfort ControlsPhasedOutTAYSTAT300CXT300C• Single Stage Heating/Cooling• 7 Day, 24 Hour or Const<strong>an</strong>tTemperature Programming• 4 Temperature Set Points Per Day• Power Stealing 4-wire• M<strong>an</strong>ual or Auto Ch<strong>an</strong>geover (FieldSelectable)PhasedOutTAYSTAT302CXT302C• 2 Heat/2 Cool• 7 Day, 24 Hour or Const<strong>an</strong>tTemperature Programming• 4 Temperature Set Points Per Day• M<strong>an</strong>ual or Auto Ch<strong>an</strong>geover (FieldSelectable)• Outdoor Temperature Display (OptionalAccessory – TAYSENS100A)PhasedOutTAYSTAT500CXT500C• 2 Heat/1 Cool• 3 Heat/2 Cool Heat Pumps• 7 Day, 24 Hour or Const<strong>an</strong>tTemperature Programming• 4 Temperature Set Points Per Day• M<strong>an</strong>ual or Auto Ch<strong>an</strong>geover (FieldSelectable)• Outdoor Temperature Display(Optional Accessory – TAYSENS100A)• Bright Backlight Display• Outdoor Temperature Display (OptionalAccessory – TAYSENS100A)• Bright Backlight Display• 4-wire hook up-register is supplied forsystems with electric heat• Filter Cle<strong>an</strong>/Replacement Key (FieldAdjustable)PHASED• No Batteries Required; Super CapContinues Clock for <strong>an</strong> Average of30 Minutes• Programming <strong>an</strong>d Other FunctionsStored in Perm<strong>an</strong>ent “E-PROM” Memory• Conventional or Adaptive IntelligentRecovery (Field Selectable)• Daylight Savings Time KeyOUT• Gas only models do not need resistor• Programmable F<strong>an</strong> – F<strong>an</strong> c<strong>an</strong> beProgrammed in the “ON” or “AUTO”Mode for Each Period• Bright Backlight Display• Filter Cle<strong>an</strong>/Replacement Key (FieldAdjustable)• No Batteries Required; Super CapContinues Clock for <strong>an</strong> Average of30 Minutes• Programming <strong>an</strong>d Other FunctionsPHASEDStored in Perm<strong>an</strong>ent “E-PROM” Memory• Must be set for 2 Heat/2 Cool by installer• Factory shipped 2 Heat/ 1 Cool• Conventional or Adaptive IntelligentRecovery (Field Selectable)• Daylight Savings Time Key• Programmable F<strong>an</strong> – F<strong>an</strong> c<strong>an</strong> beProgrammed in the “ON” or “AUTO”Mode for Each Period• Minimum Compressor Run Time(Factory Set to 10 Minutes, FieldAdjustable)Models, Field Adjustable); i.e. F<strong>an</strong> “G”is Activated with “W” (Electric HeatInstallations)• “Comfort "R"” Enh<strong>an</strong>ced Cooling forPSC Motors, Field Activated (This isOnly a Portion of Comfort "R" that isAchieved with Variable Speed Equip-OUTment)PHASED30 Minutes• Filter Cle<strong>an</strong>/Replacement Key (FieldAdjustable)• No Batteries Required; Super CapContinues Clock for <strong>an</strong> Average of• Field Select 1 or 2 Stage• Programming <strong>an</strong>d Other FunctionsStored in Perm<strong>an</strong>ent “E-PROM” Memory• Conventional or Adaptive IntelligentRecovery (Field Selectable)• Factory shipped 2 Heat/1 CoolOUT• If needed, Installation setup allowscontrol to be used in 3 Heat/1 Cool• Daylight Savings Time Key• Programmable F<strong>an</strong> – F<strong>an</strong> c<strong>an</strong> beProgrammed in the “ON” or “AUTO”Mode for Each Period• Minimum Compressor Run Time(Factory Set to 10 Minutes, FieldAdjustable)• Vacation/Leave Program; Will HoldVacation/Leave Temperature for up to256 Days• Field Temperature Re-Calibration Offset(Field Adjustable); Allows Installer to SetThermostat to Customer’s Wall-MountedThermostat Setting• F<strong>an</strong>-On Heat with Terminal (Heat/CoolModels, Field Adjustable); i.e. F<strong>an</strong> “G”is Activated with “W” (Electric HeatInstallations)• “Comfort "R"” Enh<strong>an</strong>ced Cooling forPSC Motors, Field Activated (This isOnly a Portion of Comfort "R" that isAchieved with Variable Speed Equipment)• Finish: Bright White• Vacation/Leave Program; Will HoldVacation/Leave Temperature for up to256 Days• Field Temperature Re-Calibration Offset(Field Adjustable); Allows Installer to SetThermostat to Customer’s Wall -Mounted Thermostat Setting• F<strong>an</strong>-On Heat with Terminal (Heat/Cool• Finish: Bright White• Minimum Compressor Run Time (FactorySet to 10 Minutes, Field Adjustable)• Vacation/Leave Program; Will HoldVacation/Leave Temperature for up to256 Days• Field Temperature Re-Calibration Offset(Field Adjustable); Allows Installer to SetThermostat to Customer’s Wall-MountedThermostat Setting• F<strong>an</strong>-On Heat with Terminal (Heat/CoolModels, Field Adjustable); i.e. F<strong>an</strong> “G” isActivated with “W” (Electric HeatInstallations)•“Comfort "R"” Enh<strong>an</strong>ced Cooling forPSC Motors, Field Activated (This is Onlya Portion of Comfort "R" that isAchieved with Variable Speed Equipment)• Finish: Bright WhiteCCZO-3 Effective 1/1/06


Programmable 5/2 DayComfort ControlsTCONT600ATCONT602A• 1 Heat/1 Cool• 5/2 or 5/1/1 Programming• Simple to Install <strong>an</strong>d Use• Front Wired (Wires attach to wallplates)• St<strong>an</strong>dard Wiring Terminal Block• Easy to follow Sequential Programming• Inside <strong>an</strong>d set temperatures displayedsimult<strong>an</strong>eously• 2 Heat/2 Cool• 5/2 or 5/1/1 Programming• Simple to Install <strong>an</strong>d Use• Front Wired (Wires attach to wallplates)• St<strong>an</strong>dard Wiring Terminal Block• Easy to follow SequentialProgramming• Inside <strong>an</strong>d set temperatures displayedsimult<strong>an</strong>eously• Plain l<strong>an</strong>guage (no symbols)• Easy battery access• Easy to underst<strong>an</strong>d soft key controls• Energy Star• BAYCOVR700A - Wall cover plateDimensions:• 5.81” w x 3.56” h• Finish: Bright White• Plain l<strong>an</strong>guage (no symbols)• Easy battery access• Easy to underst<strong>an</strong>d soft key controls• BAYCOVR700A - Wall cover plate• Energy StarDimensions:• 5.81” w x 3.56” h• Finish: Bright WhiteEffective 1/1/06BAYCOVR700APhasedOutTAYSTAT340PhasedOutTAYSTAT350PhasedOutHeat PumpTAYSTAT540Application:• Use with TCONT600A Series ComfortControls• 1 Heat (Gas/Electric)/1 Cool• Heat/Off/Cool System Switch• Power Stealing 4 Wire• 5/2 Programmable• Auto/On F<strong>an</strong> Switch• 2 Heat (Gas)/1 Cool• Heat/Off/Cool System Switch• 5/2 Programmable• Auto/On F<strong>an</strong> Switch• M<strong>an</strong>ual Ch<strong>an</strong>geoverPHASED OUT• Super Cap Continues Clock for <strong>an</strong>Average of 30 Minutes• 2 Heat/1 Cool• Heat/Off/Cool/Emergency HeatSystem Switch• 5/2 Programmable• Auto/On F<strong>an</strong> SwitchPHASED OUT• M<strong>an</strong>ual Ch<strong>an</strong>geover• Super Cap Continues Clock for <strong>an</strong>Average of 30 MinutesCCZO-4• Finish: Bright WhitePHASED OUT• M<strong>an</strong>ual Ch<strong>an</strong>geover• Super Cap Continues Clock for <strong>an</strong>Average of 30 Minutes• Programming Stored In Perm<strong>an</strong>ent“E-PROM” Memory• No Batteries• Fuel Selection Switch (Gas/Electric)• Adjustable Heating Cycle Rate• Finish: Bright White• Programming Stored In Perm<strong>an</strong>ent“E-PROM” Memory• No Batteries• Adjustable Heating Cycle Rate• 6-wire connection• Finish: Bright White• Programming Stored In Perm<strong>an</strong>ent“E-PROM” Memory• No Batteries• Adjustable Heating Cycle Rate• Finish: Bright White


Non-ProgrammableComfort ControlsTCONT401A• Auto Ch<strong>an</strong>geover• Backlit Display & Keys• Comfort Information Compartment• Energy Savings Mode• Filter Reminder• Outdoor Temperature Sensor• Keypad LockApplication (3-9 Wire Hookup -2for Outdoor Sensor) Heat Pump*or A/C• 1 Stage Heat Pump**, 1 Stage AuxHeat• 1 Stage Heat Pump**, 0 Stage AuxHeat• 1 Stage Cool, 2 Stage Heat(Gas, Electric or Oil*)• 1 Stage Cool, 1 Stage Heat(Gas, Electric or Oil*)• 1 Stage Cool, 0 Stage Heat• 0 Stage Cool, 2 Stage Heat(Gas, Electric or Oil*)• 0 Stage Cool, 1 Stage Heat(Gas, Electric or Oil*)Dimensions:6.75" w x 4.52" h• Finish: Bright White* Requires external relay for oil furnaceapplications.** External TAYPLUS103A required fordual fuel applications.BAYSEN01ATEMPAA required foroutdoor temperature sensing <strong>an</strong>ddisplayTCONT402A• Auto Ch<strong>an</strong>geover• Backlit Display & Keys• Comfort Information Compartment• Energy Savings Mode• Filter Reminder• BAYSEN01ATEMPAA-OutdoorTemperature Sensor included*• Keypad LockApplication (3-9 Wire Hookup -2for Outdoor Sensor) Heat Pump*or A/C• 3 Heat/2 Cool• No external Dual Fuel Kit Required• ZZSENSAL0400AA - Remote IndoorTemperature SensorDimensions:6.75" w x 4.52" h• Finish: Bright White* Requires external relay for oil furnaceapplications.* Installation is required for outdoortemperature sensing <strong>an</strong>d display* BAYSEN01ATEMPAA required foroutdoor temperature sensing <strong>an</strong>ddisplayTCONT200A• Auto Ch<strong>an</strong>geover• Back Lit Display & Keys• Comfort Information Compartment• Energy Savings Mode• Filter Reminder• Key Pad LockDimensions:• 4.25" (W) x 5.33" (H)Application (4 wire hookup - powerstealing)*• 1 Heat/1 Cool (Gas, Oil or electric)• 1 Heat/0 Cool (Gas, Oil or electric)• 0 Heat/1 Cool• Finish: Bright WhiteCCZO-5 Effective 1/1/06


Non-ProgrammableComfort ControlsPhasedOutPhasedOutPhasedOutHeatPhasedOutHeatPhasedOutPhasedOutTAYSTAT380• 2 Heat (Gas)/1 Cool• Heat/Off/Cool System Switch• Auto/On F<strong>an</strong> SwitchPHASED OUT• M<strong>an</strong>ual Ch<strong>an</strong>geover• Digital DisplayHeat PumpTAYSTAT570• 2 Heat /1 Cool• Heat/Off/Cool/Emergency HeatPHASED OUTSystem Switch• Auto/On F<strong>an</strong> Switch• M<strong>an</strong>ual Ch<strong>an</strong>geoverHeat PumpTAYSTAT575• 3 Heat /2 Cool (Field Selectable)• Factory Ships 2 Heat/1 CoolPHASED OUT• Lighted Digital Display• Emergency Heat/Off/Cool Auto SystemKeyboardTAYSTAT375• 2 Heat (Gas/Electric) /2 Cool (FieldSelectable)• Factory Ships 2 Heat/1 CoolPHASED OUT• Lighted Digital Display• Perm<strong>an</strong>ent Temperature SettingRetentionTAYSTAT370• 1 Heat (Gas)/1 Cool• Power Stealing 4 Wire• Heat/Off/Cool System SwitchPHASED OUT• Auto/On F<strong>an</strong> Switch• M<strong>an</strong>ual Ch<strong>an</strong>geoverTAYSTAT371• 1 Heat (Electric)/1 Cool• Power Stealing 4 Wire• Resistor must be installed (shippedPHASED OUTwith control)• Heat/Off/Cool System Switch• Auto/On F<strong>an</strong> Switch• No Batteries• Perm<strong>an</strong>ent Temperature SettingRetention• Adjustable Heating Cycle Rate• Finish: Bright White• Digital Display• No Batteries• Perm<strong>an</strong>ent Temperature SettingRetention• Finish: Bright White• Auto/On F<strong>an</strong> Switch Keyboard• No Batteries• M<strong>an</strong>ual or Auto Ch<strong>an</strong>geover• Perm<strong>an</strong>ent Temperature SettingRetention• Finish: Bright White• Heat/Off/Cool/Auto System Keyboard• Auto/On F<strong>an</strong> Switch Keyboard• M<strong>an</strong>ual or Auto Ch<strong>an</strong>geover• No Batteries• Finish: Bright White• Digital Display• No Batteries• Perm<strong>an</strong>ent Temperature SettingRetention• Adjustable Heating Cycle Rate• Finish: Bright White• M<strong>an</strong>ual Ch<strong>an</strong>geover• Digital Display• No Batteries• Perm<strong>an</strong>ent Temperature SettingRetention• Finish: Bright WhiteEffective 1/1/06CCZO-6


Remote SensorsBAYSEN02ATEMPAA• Outdoor Temperature Sensor for Usewith TCONT800, 802, 803• Accuracy +/– 1°F from –40 to 120°FPhasedOutTAYSENS100A• Outdoor Temperature Sensor for Usewith TAYSTAT300C, 302C, 500C, 575<strong>an</strong>d 375• Accuracy +/– 1°F from –40 to 120°F• Finish: Bright WhitePHASED OUTBAYSEN01ATEMPAA• Outdoor Temperature Sensor for Usewith TCONT401A & 402A• Accuracy+/- 15°F over 32°F to 100°F• Display R<strong>an</strong>ge-40°F to 140°FZZSENSAL0400AA• Indoor Sensor for Use withTCONT402 Comfort Controls• Operating Ambient TemperatureR<strong>an</strong>ge: 20° to 120°F (-6.7° to 48.9°C)• Display R<strong>an</strong>ge: 20° to 120°F(-6.7° to 48.9°C)• Sensor Accuracy: +/-.5°F at 75°F• Operating Relative Humidity: 5% to90% non-condensingDimensions in in. (mm):• 1.54 (39) wide x 1.93 (49) high x .625(1.6) deep• Storage Temperature: -40° to 140°F(-40° to 60°C)• Finish: WhiteZZSENSAL0800AA• Indoor Temperature Sensor for Usewith TCONT800, 802, 803• Operating Ambient TemperatureR<strong>an</strong>ge: 45 to 88°F (7.2 to 32°C)• Display R<strong>an</strong>ge: 0 to 99°F (-18 to 37°C)• Sensor Accuracy: +/-1.5°F at 70°F(+/-.84 at 21°C)• Operating Relative Humidity: 5% to95% non-condensingDimensions in in. (mm):• 1.50 (38) wide x 2.28 (58) high x .70(18) deep• Finish: WhiteCCZO-7 Effective 1/1/06


Humidity ControlHumidity ControlBAYSTAT253A• Heating Cycle Humidity ControlThe humidity control provides automaticlow voltage control of humidifiers incentral heating <strong>an</strong>d cooling applications.It has <strong>an</strong> spst, snap-acting, dust-proofswitch that opens when humidity risesabove the control setting. It is designedfor wall or surface duct mounting.• Cooling Cycle Humidity*When activated, the humidity controllowers the furnace/air h<strong>an</strong>dler blowerspeed, reducing air velocity over thefurnace/air h<strong>an</strong>dler coil <strong>an</strong>d removing agreater amount of moisture from the air.• Bright White Finish* For use w/variable speed indoor products"ONLY"Relay Hook-UpBAY24X042Relay• BAY24X042 relay for f<strong>an</strong> operationwhen using electric heat.• This sample hook-up diagramillustrates Field Connections forcooling only units, electric heat <strong>an</strong>dautomatic ch<strong>an</strong>ge over control.• On a call for heat, the relay providesfor inst<strong>an</strong>t f<strong>an</strong>-on. Without the relay,you will get no airflow or heat! Relayis not needed with Fossel Fuel onHeat Pump applications.Effective 1/1/06CCZO-8


Indoor F<strong>an</strong> Delay Relay KitBAY24X045• For application to furnaces <strong>an</strong>d airh<strong>an</strong>dlers with cooling coils equippedwith capillary tube or 15% bleedexp<strong>an</strong>sion valve components.• This kit allows the indoor f<strong>an</strong> tocontinue to run a short time after theoutdoor unit shuts off for increasedcooling efficiency.• The kit contains: 1 solid state timedelay relay with four (4) color codedwires, 1 wiring diagram, 1 notice label,1 mounting screw.Outdoor Thermostat KitTAYSTAT250B• The outdoor thermostat (ODT) isdesigned to turn "ON" the supplementaryheater at a pre-selectedoutdoor temperature.• The number <strong>an</strong>d setting of the ODTis dependent on the heat loss of thestructure <strong>an</strong>d capacity of the heatingsystem installed.• This model ODT gives a temperaturer<strong>an</strong>ge for 44°F. to -10°F. (See figure 1for settings). The switching action issingle pole/double throw, opening ontemperature rise <strong>an</strong>d closing ontemperature fall, completing thecircuit through the thermostat.CCZO-9 Effective 1/1/06


Cooling Only <strong>an</strong>d Heating OnlyComfort ControlsSubbase is required(shown with 187 subbase)Cooling OnlyBAY28X186• 0 Heat/2 Cool• C<strong>an</strong> be Used for Economizer Operation• Use with BAY28X187 Subbase only• Off/Auto System Switch• Auto/On F<strong>an</strong> Switch• Clear Plastic Set Point Lever• Thermometer c<strong>an</strong> be Calibrated• Finish: Beige <strong>an</strong>d GoldCooling OnlyBAYSTAT304• 0 Heat/1 Cool• Off/Auto/F<strong>an</strong> System Switch• Clear Plastic Set Point Lever• Finish: Bright WhiteHeating OnlyBAYSTAT303• 1 Heat/0 Cool• Gas Heat Compatible• Off/Auto/F<strong>an</strong> System Switch• Clear Plastic Set Point Lever• Not Electric Heat Compatible• Requires BAY24X042 Relay forIndoor F<strong>an</strong> Operation when usedfor Electric Heat• Adjustable Heat Anticipator• Finish: Bright WhiteEffective 1/1/06CCZO-10


Single StageComfort ControlsSingle StageAY28X092• 1 Heat/1 Cool• M<strong>an</strong>ual Ch<strong>an</strong>geover• Heat/Off/Cool System Switch• On Auto F<strong>an</strong> Switch• Set Point Dial• Gas Heat Compatible• Electric Heat Compatible; jumperterminals 1 & 2 together• Calibrate by Adjusting the CamRider Screw• Adjustable Heat Anticipator• Finish: Bright WhiteSubbase is required(shown with 185 subbase)Single StageBAY28X182• 1 Heat/1 Cool• With BAY28X185 Subbase:M<strong>an</strong>ual Ch<strong>an</strong>geoverInst<strong>an</strong>t On F<strong>an</strong> (for Electric Heat)Heat/Off/Cool System SwitchAuto/On F<strong>an</strong> Switch• With BAY28X187 Subbase:Automatic Ch<strong>an</strong>geoverOff/Auto System SwitchAuto/On F<strong>an</strong> Switch• Requires BAY24X042 Relay forIndoor F<strong>an</strong> Operation when usedfor Electric Heat• Clear Plastic Set Point Levers• Adjustable Heat Anticipator• Thermometer c<strong>an</strong> be Calibrated• Finish: Beige <strong>an</strong>d GoldSingle StageBAYSTAT008• 1 Heat/1 Cool• M<strong>an</strong>ual Ch<strong>an</strong>geover• Includes Stat <strong>an</strong>d Subbase• Set Point Dial• Calibrate with Honeywell CalibrationWrench (Part #104994A)• Cool/Off Heat System Switch• Auto/On F<strong>an</strong> Switch• Adjustable Heat Anticipator• Requires BAY24X042 Relay forIndoor F<strong>an</strong> Operation when usedfor Electric Heat• Finish: GoldSingle StageBAYSTAT305• 1 Heat/1 Cool• M<strong>an</strong>ual Ch<strong>an</strong>geover• Heat/Off/Cool System Switch• On Auto F<strong>an</strong> Switch• Clear Plastic Set Point Lever• Gas Heat Compatible• Electric Heat Compatible; jumperterminals 1 & 2 together• Adjustable Heat Anticipator• Finish: Bright WhiteCCZO-11 Effective 1/1/06


Multiple StageComfort ControlsSubbase is required(shown with 184 subbase)Multiple StageBAY28X183• 2 Heat/2 Cool-C<strong>an</strong> be Used forEconomizer Operation• With BAY28X184 Subbase:Automatic or M<strong>an</strong>ual Ch<strong>an</strong>geoverOff Heat/Auto/Cool System SwitchAuto/On F<strong>an</strong> Switch• Requires AY24X042 Electric HeatRelay• With BAY28X185 Subbase:M<strong>an</strong>ual Ch<strong>an</strong>geoverInst<strong>an</strong>t On F<strong>an</strong> (for Electric Heat)Heat/Off/Cool System SwitchAuto/On F<strong>an</strong> Switch• With BAY28X187 Subbase:Automatic Ch<strong>an</strong>geoverOff/Auto System SwitchAuto/On F<strong>an</strong> Switch• Requires AY24X042 Electric HeatRelay• Clear Plastic Set Point Levers• Adjustable Heat Anticipator• Thermometer c<strong>an</strong> be Calibrated• Finish: Beige <strong>an</strong>d GoldMultiple StageBAYSTAT010• 2 Heat/2 Cool-C<strong>an</strong> be Used forEconomizer Operation• Automatic Ch<strong>an</strong>geover• Includes Stat <strong>an</strong>d Subbase• Off/Auto System Switch• Auto/On F<strong>an</strong> Switch• Clear Plastic Set Point Levers• Thermometer c<strong>an</strong> be Calibrated• Adjustable Heat Anticipator• Finish: Beige <strong>an</strong>d GoldMultiple StageBAYSTAT012• 1 Heat/2 Cool-C<strong>an</strong> be Used forEconomizer Operation• M<strong>an</strong>ual Ch<strong>an</strong>geover• Includes Stat <strong>an</strong>d Subbase• Heat/Off/Cool System Switch• Auto/On F<strong>an</strong> Switch• Clear Plastic Set Point Levers• Thermometer c<strong>an</strong> be Calibrated• Adjustable Heat Anticipator• Finish: Beige <strong>an</strong>d GoldMultiple StageTAYSTAT241• 2 Heat/1 Cool• M<strong>an</strong>ual Ch<strong>an</strong>geover• For 2-stage Gas Furnaces• Heat/Off/Cool System Switch• Auto/On F<strong>an</strong> Switch• Clear Plastic Set Point Lever• Requires AY24X042 (DPDT Relay) forindoor f<strong>an</strong> operation when used forElectric Heat• Finish: Bright WhiteEffective 1/1/06CCZO-12


Heat PumpComfort ControlsHeat PumpBAY28X138A• 2 Heat/1 Cool• Automatic Ch<strong>an</strong>geover• Off/Auto System Switch• Auto/On F<strong>an</strong> Switch• Normal/Emergency Heat Switch• Auxiliary <strong>an</strong>d Emergency HeatIndicator Lights• Clear Plastic Set Point Levers• Deluxe Clear Plastic Cover• Minimum differential between Heating<strong>an</strong>d Cooling is 4°F• Thermometer c<strong>an</strong> be Calibrated• Finish: Bright WhiteHeat PumpBAY28X153A• 3 Heat/2 Cool• Automatic or M<strong>an</strong>ual Ch<strong>an</strong>geover• C<strong>an</strong> be Used for EconomizerOperation• Auto Heat/Off/Cool System Switch• High Auto Low F<strong>an</strong> Switch• Normal Emergency Heat Switch• Auxiliary <strong>an</strong>d Emergency HeatIndicator Lights• Used with System 2• Deluxe Clear Plastic Cover• Clear Plastic Set Point Levers• Minimum differential between heating<strong>an</strong>d cooling is 4°F• Thermometer c<strong>an</strong> be Calibrated• Includes Stat & Subbase• Finish: Bright WhiteHeat PumpBAYSTAT239A• 2 Heat/1 Cool• M<strong>an</strong>ual Ch<strong>an</strong>geover• Includes Stat & Subbase• Heat/Off/Cool System Switch• Auto/On F<strong>an</strong> Switch• Normal/Emergency Heat Switch• Auxiliary <strong>an</strong>d Emergency HeatIndicator Lights• Thermometer c<strong>an</strong> be Calibrated• Clear Plastic Set Point Lever• Finish: Bright WhiteHeat PumpBAYSTAT240A• 2 Heat/1 Cool• M<strong>an</strong>ual Ch<strong>an</strong>geover• Heat/Off/Cool System Switch• Auto/On F<strong>an</strong> Switch• Normal Emergency Heat Switch• Auxiliary <strong>an</strong>d Emergency HeatIndicator Lights• Thermometer c<strong>an</strong> be Calibrated• Clear Plastic Set Point Lever• Finish: Bright WhiteCCZO-13 Effective 1/1/06


Zone Comfort ControlsBAYSTAT040B• BAYBASE008A: Single Stage1 Heat/1 Cool• BAYBASE006A: Multi Stage2 Heat/2 Cool-C<strong>an</strong> be used forEconomizer Operation• BAYBASE007A: Multi StageHeat Pump-3 Heat/2 Cool-C<strong>an</strong> beused for Economizer Operation• Digital display indicating the time ofday, the day of the week, roomtemperature, current program operatingmode, <strong>an</strong>d current active stage• Inst<strong>an</strong>t override, continuous ortemporary 3 hour timed• Automatic adjustment of temperaturesup to four times a day• L.C.D. readout in F or C (Celsius) <strong>an</strong>d12 or 24-hour clock• Preferential Rate Control (PRC)minimizes overshooting <strong>an</strong>d preventsroom temperature deviating fromsetpoint under varying load conditions(zero droop)• PRC provides smart recovery fromoffset to minimize use of supplementalelectric heat• Keyboard disable to prevent tampering• 100% solid state• No outdoor thermostat required, utilizescomputer controlled staging (multistage)• Auto f<strong>an</strong> during setback (optional)• No <strong>an</strong>ticipator required• Automatic or M<strong>an</strong>ual ch<strong>an</strong>geover• Built-in minimum on-off time delaysensure short cycle protection• Lockable cover• Equipment short cycle protection againstpower outages longer th<strong>an</strong> 1/2 second.Equipment turns off for 6 minutes• No accessories required. Each unit iscomplete <strong>an</strong>d ready for installation• Finish: Bright WhiteRemote SensorBAYSENS033A• Remote Sensor for use withBAYSTAT040B• Allows convenient thermostat location<strong>an</strong>d optimum temperature sensinglocation• Maximum dist<strong>an</strong>ce from thermostatto sensor = 1000 ft.• Use 3 conductor (18-26 AWG)shielded, <strong>an</strong>d insulated cable• Vendor: Honeywell• Finish: Bright WhiteBAYSENS034A• Return Air Remote TemperatureSensor for use with BAYSTAT040BEffective 1/1/06CCZO-14


ComfortLink TM SystemZSCNTRAL010The System ControllerThe Controller is the master <strong>an</strong>d center hub ofthe system. It acquires information. From theinformation it gathers, it establishes thesystem's operation. The main functions of thecontroller are communications, computation,activation <strong>an</strong>d control.Must be used with <strong>an</strong>y ZUSTATAL** Wall Mounted Sensor.Use:• Two Piece Control• Home Automation Interface "Open Protocol"• Extensive Diagnostics <strong>an</strong>d MonitoringSystemIntegrated Zone TM SystemAssembly <strong>an</strong>d AccessoriesZSASSMAL010• Full modulating zone operation• Single <strong>an</strong>d two-stage heating products• Single <strong>an</strong>d two-stage cooling products• Indoor f<strong>an</strong> motors -- h<strong>an</strong>dles both VariableSpeed <strong>an</strong>d PSC induction motors• Heat pump compatible• Fossil fuel (gas <strong>an</strong>d oil furnace)compatible• Wet-heat (hot water coil in air h<strong>an</strong>dler)compatible• Zone card adjustable from 20 to 100%system airflow• By-pass offering• Relief to zones adjustment (st<strong>an</strong>dardfeature)ZSASSMAL010: Zoning AssemblyContains the Basic Control components (excluding wall mounted sensors) for either I) a three(3) zone system, or II) a two (2) zone system with by-pass. Control Components included arethe system controller, one (1) four-zone exp<strong>an</strong>der board with three (3) zone cards. All mountedin a metal enclosure that will accept <strong>an</strong> additional four-zone exp<strong>an</strong>der board for up to eight (8)zones. Discharge Air Sensor is included <strong>an</strong>d packaged in a 2x2x11 box. For single <strong>an</strong>d twostageproducts (except XL16i); cooling, gas, oil, electric heat, <strong>an</strong>d heat pump systems.ZZEXPDAL010: Four-Zone Exp<strong>an</strong>der BoardUsed to exp<strong>an</strong>d ZSASSMAL010 Basic Zoning Assembly up to eight (8) zones or seven (7)zones with by-pass.ZZCARDAL010: Zone/By-Pass CardControls a single zone's damper(s) or the by-pass damper. Zone <strong>an</strong>d by-pass airflows are seton each card. One card required per zone.Note: XL16i models, both cooling or heat pump models, are not approved for <strong>Tr<strong>an</strong>e</strong> Comfort Link Zoning System.CCZO-15 Effective 1/1/06


Sensors For<strong>Tr<strong>an</strong>e</strong> ComfortLink TM SystemZUSTATALMS10ProgrammableSensorZUSTATALP510Non-ProgrammableSensorZUSTATALS510CommunicatingComfort SensorZUSTATAL0310Room/RemoteSensorZZSENSAL011orOutoor TemperatureSensorTAYSTAT265B• Continuously Displays:– Indoor Temperature– Thermostat Mode– Programmable– F<strong>an</strong> Mode– Time of Day– Day of Week– System Staging– Active ProgramSlimline Wall Mount Zone Scheduler/Programmable Display Sensor: Same features as ZUSTATALP510 sensor.C<strong>an</strong> be used to program <strong>an</strong>d schedule up to eight (8) zones. Copy button for ease of programming time/temperatureschedules from other zones. Use with ZSASSMAL010 only.• Continuously Displays:– Indoor Temperature– Thermostat Mode– Programmable– F<strong>an</strong> Mode– Time of Day– Day of Week– System Staging– Active Program• Continuously Displays:– Indoor Temperature– Thermostat Mode– F<strong>an</strong> Mode• Remote Sensor for:– ZUSTATALS51– ZUSTATALP51– ZUSTATALMS10• Backlight Display• Battery Backup• Programmable Setback (Four Set Points)• Must be applied with ZSCNTRAL010• Seven Day Programming• Temporary Program Override• Hold Set Point• Outdoor Temperature Displayupon Request (TAYSTAT265BSensor Required)• Finish: Bright White*When used as a Two PieceControl, ZSCNTRAL010 Mustbe AppliedSlimline Wall Mount Programmable Display Sensor: Same basic features as ZUSTATALS510 sensor with seven dayschedule programming which allows four separate time/tempeature settings per 24-hour period. Backlit LCD for easy view<strong>an</strong>d programming. Displays day of week in addition to time <strong>an</strong>d temperature. Use with either ZSASSMAL010 orZSCNTRAL010.• Continuously Displays:– Indoor Temperature– Thermostat Mode– F<strong>an</strong> Mode– Time of Day– Day of Week– System Staging• Backlight Display• Battery Backup• Must be applied with ZSCNTRAL010• Outdoor Temperature Display uponRequest (TAYSTAT265B SensorRequired)• Finish: Bright White*When used as a Two Piece Control,ZSCNTRAL010 Must be AppliedSlimline Wall Mount Display Sensor: Comfort sensor continuously displays the time <strong>an</strong>d indoor temperature backlitLCD for easy view. Used to ch<strong>an</strong>ge indoor temperature settings <strong>an</strong>d conditioning modes. When used withTAYSTAT265B sensor, outdoor temperature c<strong>an</strong> be viewed. Use with either ZSASSMAL010 or ZSCNTRAL010.• Outdoor Temperature Display uponRequest (TAYSTAT265B SensorRequired)• Must be applied with ZSCNTRAL010Petite Wall Mount Display Sensor: Slimline design comfort sensor continuously displays indoor temperature. Used toch<strong>an</strong>ge indoor temperature settings <strong>an</strong>d conditioning modes for cool, heat, auto, or continuous f<strong>an</strong>. When used withTAYSTAT265B sensor, outdoor temperature c<strong>an</strong> be viewed. Used with either ZSASSMAL010 or ZSCNTRAL010. Notbacklit.Remote Analog Temperature Sensor: Temperature only sensor. Senses the temperature where located. When usedfor a zone temperature sensor, must be used with ZUSTATALMS1 Master Scheduler. C<strong>an</strong> be used as a remote sensorfor ZUSTATALS51, ZUSTATALP51, or ZUSTATALMS1.• Outdoor Sensor for:– ZUSTATALS51– ZUSTATALP51• Backlight Display• Battery Backup• Programmable Setback (Four Set Points)• Must be applied with ZSCNTRAL010• Seven Day Programming• Temporary Program Override• Hold Set Point• Finish: Bright White• Finish: Bright White• Outdoor Temperature Displayupon Request (TAYSTAT265BSensor Required)• Finish: Bright White*When used as a Two PieceControl, ZSCNTRAL010 Mustbe Applied• Finish: Bright WhiteOutdoor Temperature Sensor: Outdoor temperature only sensor. C<strong>an</strong> be used with ZUSTATALS51, ZUSTATALP51, orZUSTATALMS1. Weather proofed.Effective 1/1/06CCZO-16


Integrated Zone TM SystemDampers• Fully modulating damper• Low power requirement 2.5 VA @ 24v• Factory mounted motor actuator• 53 inch-pound running torque• 40 inch-pound break away torque• Magnetic clutch for torque protection• Adjustable rotation stops allow for minimum/maximum airflowTable CCZO-17-A — Specifications: Round Dampers• 60 second travel time• M<strong>an</strong>ual gear release• Color coded wiring harness for easy fieldhook-up• Low leakage <strong>Tr<strong>an</strong>e</strong> design• 18 guage construction• 24 volt operationModel Power Fits Round Mfg. ShippingNumber Supply Description Duct Size Pl<strong>an</strong>t Weight Diameter LengthZD0006ALF0B0 24 VAC 6" Modulating Damper 6" TY 8 6.375 12.00ZD0008ALF0B0 24 VAC 8" Modulating Damper 8" TY 10 8.375 12.00ZD0010ALF0B0 24 VAC 10" Modulating Damper 10" TY 13 10.375 16.00ZD0012ALF0B0 24 VAC 12" Modulating Damper 12" TY 15 12.375 16.00ZD0014ALF0B0 24 VAC 14" Modulating Damper 14" TY 22 14.375 20.00ZD0016ALF0B0 24 VAC 16" Modulating Damper 16" TY 24 16.375 20.00WH• Bottom mount actuator motor• Low power requirement 2.5 VA @ 24v• Fully modulating damper• Factory mounted motor actuator• 53 inch-pound running torque• 40 inch-pound break away torque• Magnetic clutch for torque protection• Adjustable rotation stops allow for minimum/maximum airflow• 60 second travel time• M<strong>an</strong>ual gear release• Color coded wiring harness for easy fieldhook-up• Low leakage <strong>Tr<strong>an</strong>e</strong> design• 18 guage construction• 24 volt operation• Long life PTC High Impact ABS gearsdesigned <strong>an</strong>d tested to exceed 200,000cyclesTable CCZO-17-B — Specifications: Rect<strong>an</strong>gular Dampers with Bottom Mount ActuatorUncratedModel Power Dimensions (in.) Mfg. ShippingNumber Supply Description H W Pl<strong>an</strong>t WeightZD0810ALBMB0 24 VAC 8" height x 10" width 8 10 TY 16ZD0814ALBMB0 24 VAC 8" height x 14" width 8 14 TY 20ZD0820ALBMB0 24 VAC 8" height x 20" width 8 20 TY 26ZD1014ALBMB0 24 VAC 10" height x 14" width 10 14 TY 28ZD1020ALBMB0 24 VAC 10" height x 20" width 10 20 TY 35H• Side mount actuator motor• Low power requirement 2.5 VA @ 24v• Fully modulating damper• Factory mounted motor actuator• 53 inch-pound running torque• 40 inch-pound break away torque• Magnetic clutch for torque protection• Adjustable rotation stops allow for minimum/maximum airflow• 60 second travel time• M<strong>an</strong>ual gear release• Color coded wiring harness for easy fieldhook-up• Low leakage <strong>Tr<strong>an</strong>e</strong> design• 18 guage construction• 24 volt operation• Long life PTC High Impact ABS gearsdesigned <strong>an</strong>d tested to exceed 200,000cyclesWTable CCZO-17-C — Specifications: Rect<strong>an</strong>gular Dampers with Side Mount ActuatorUncratedModel Power Dimensions (in.) Mfg. ShippingNumber Supply Description H W Pl<strong>an</strong>t WeightZD0812ALSMB0 24 VAC 8" height x 12" width 8 12 TY 17ZD0814ALSMB0 24 VAC 8" height x 14" width 8 14 TY 20ZD0816ALSMB0 24 VAC 8" height x 16" width 8 16 TY 22ZD0818ALSMB0 24 VAC 8" height x 18" width 8 18 TY 24ZD0820ALSMB0 24 VAC 8" height x 20" width 8 20 TY 26ZD1016ALSMB0 24 VAC 10" height x 16" width 10 16 TY 29ZD1020ALSMB0 24 VAC 10" height x 20" width 10 20 TY 35CCZO-17 Effective 1/1/06


Zone Sensor UnitInstallationThe zone sensor provides the operatorcontrol <strong>an</strong>d zone temperature sensingfunctions for use with electronic unitcontrols. Refer to the appropriate unitinstallation m<strong>an</strong>ual for interconnectingwiring instructions.ZONE SENSOR LOCATIONTo ensure proper operation, select alocation on <strong>an</strong> interior wall, at a heightapproximately 5 feet above the floor,with freely circulating air of averagetemperature.Avoid Locations:• Behind doors or in corners where airdoes not freely circulate.• On <strong>an</strong> outside wall or <strong>an</strong>y wall withunheated (uncooled) areas behind thezone sensor.• Where direct sunlight or <strong>an</strong>y Source: ofradi<strong>an</strong>t heat could affect thetemperature measurements.• In line with the discharge air from theunit being controlled.Mount the zone sensor base on thewall or optional mounting plate with thewires routed through the wire accesshole in the base of the zone sensor.ZONE SENSOR CONTROLSEmergency Heat/Heat/Auto/Off/CoolThis switch determines whether theunit operates in emergency heat (EM.HEAT - for heat pumps only), heating(HEAT), automatically ch<strong>an</strong>ging fromheating to cooling as required (AUTO),heating <strong>an</strong>d cooling functions disabled(OFF), or cooling (COOL).F<strong>an</strong> Auto/F<strong>an</strong> OnThis switch determines whether theindoor f<strong>an</strong> operates during cooling <strong>an</strong>dheating cycles only (FAN AUTO) orruns continuously (FAN ON).Temperature AdjustmentsOne or two temperature adjustmentcontrols are provided to set thedesired temperature or temperaturer<strong>an</strong>ge (for unit mode AUTO). If twocontrols are present, the blue controlsets the desired temperature forcooling <strong>an</strong>d the red control sets thedesired temperature for heating.Temperature IndicatorThis indicates the temperature in thezone. The indicator has been factorycalibrated <strong>an</strong>d should not normallyrequire adjustment. If adjustment isneeded, it c<strong>an</strong> be accomplished byslowly rotating a small screwdriver inthe slot on the back of the indicatoruntil the correct temperature isobtained.Optional Remote SensorWhen using the optional remotesensor (BAYSENS017B), it should belocated in the space that is to becontrolled. Wire according to theinterconnecting wiring diagrams in theunit IOM.Installation: 18-HD60D41Source: ClarksvilleEffective 1/1/06CCZO-18


Micro ControlsZone SensorsLCD DigitalDisplay Zone SensorBAYSENS035A/031A• 7 wires required.• Non-Programmable Zone Sensor witha digital display• Used with 3-25 ton packaged units.• BAYSENS035A - Cool/Gas• BAYSENS031A - Heat PumpsAveraging RemoteZone SensorBAYSENS032A• Refer to IOM for wires required• Zone Sensor averaging only• Application where two wall mountedsensors are required• BAYSENS032A used with 3-25 Tonpackaged Gas/Cool/Heat PumpsElectronic Programmable ZoneSensors For ReliaTel TM UnitsMODEBAYSENS019C• Automatic or M<strong>an</strong>ual Ch<strong>an</strong>geoverwith System Lights• Use With:3 – 10 Ton Precedent Units12.5 – 25 Ton Voyager Units• Digital display indicating the time ofday, the day of the week, roomtemperature, current program operatingmode, <strong>an</strong>d current active stage• Continuous or 3 hour timed override• Two occupied, two unoccupiedprograms per day• L.C.D. readout in F or C (Celsius) <strong>an</strong>d12 or 24-hour clock• Keyboard disable to prevent tampering• Programming on a 7-day basis• Status indication lights displayed inDigital Display• Auxiliary relay (Form 1C)• Auto F<strong>an</strong> During Setback• No Anticipator Required• No Battery Required• No accessories required. Each unit iscomplete <strong>an</strong>d ready for installation• Remote Room Sensor (BAYSENS017B)• Vendor: Heatcraft 63J74• Finish: P<strong>an</strong>tone Cool Gray #2C• Replacement: SEN-0415• Installation: 18-HD60D29• Source: ClarksvilleCCZO-19 Effective 1/1/06


Electronic Zone Sensors ForReliaTel TM UnitsBAYSENS006B• Single Setpoint• M<strong>an</strong>ual Ch<strong>an</strong>geover• Use With:3 – 10 Ton Precedent Units T*C, Y*C12.5 – 25 Ton Voyager UnitsYCD/YCH & TCD/TCH• Heat/Off/Cool System Switch• Auto/On F<strong>an</strong> Switch• Blue Cool/Red Heat Setpoint Levers• Single Setpoint requires 4 wires forElectric/Electric• Vendor: Sunne (62822)• Finish: P<strong>an</strong>tone Cool Gray #2C• Replacement: SEN-0410• Installation – 18-HD60D28• Source: ClarksvilleBAYSENS007B• Single Setpoint• M<strong>an</strong>ual Ch<strong>an</strong>geover• Use With:3 – 10 Ton Precedent Units WSC12.5 – 20 Ton Voyager Units WCD\WCH• Heat/Off/Cool System Switch• Auto/On F<strong>an</strong> Switch• Normal/Emergency Heat Switch• Heat Indicator Light• Blue Cool/Red Heat Setpoint Levers• Single Setpoint for heat pumps systemsrequires 6 wires• Vendor: Sunne (62821)• Finish: P<strong>an</strong>tone Cool Gray #2C• Replacement: SEN-0411• Installation – 18-HD60D33• Source: ClarksvilleBAYSENS008B• Dual Setpoint• M<strong>an</strong>ual or Auto Ch<strong>an</strong>geover• Use With:3 – 10 Ton Precedent Units T*C, Y*C12.5 – 25 Ton Voyager UnitsYCD/YCH & TCD/TCH• Heat/Auto/Off/Cool Switch• Auto/On F<strong>an</strong> Switch• Blue Cool/Red Heat Setpoint Levers• Vendor: Sunne (62826)• Finish: P<strong>an</strong>tone Cool Gray #2C• Replacement: SEN-0408• Installation – 18-HD60D34• Source: ClarksvilleBAYSENS009B• Dual Setpoint• M<strong>an</strong>ual or Auto Ch<strong>an</strong>geover• Use With:3 – 10 Ton Precedent Units WSC12.5 – 20 Ton Voyager Units WCD\WCH• Heat/Auto/Off/Cool Switch• Auto/On F<strong>an</strong> Switch• Normal/Emergency Heat Switch• Heat Indicator Light• Blue Cool/Red Heat Setpoint Levers• Vendor: Sunne (62825)• Finish: P<strong>an</strong>tone Cool Gray #2C• Replacement: SEN-0412• Installation – 18-HD60D35• Source: ClarksvilleBAYSENS010B• Dual Setpoint• M<strong>an</strong>ual or Auto Ch<strong>an</strong>geover• Use With:3 – 10 Ton Precedent Units T*C, Y*C12.5 – 25 Ton Voyager Units YCD/YCH &TCD/TCH• Heat/Auto/Off/Cool Switch• Auto/On F<strong>an</strong> Switch• System On/Heat/Cool/ServiceIndicator Lights• Blue Cool/Red Heat Setpoint Levers• Vendor: Sunne (62823)• Finish: P<strong>an</strong>tone Cool Gray #2C• Replacement: SEN-0413• Installation – 18-HD60D36• Source: ClarksvilleEffective 1/1/06CCZO-20


Electronic Zone Sensors ForReliaTel TM UnitsBAYSENS011B• Dual Setpoint• M<strong>an</strong>ual or Auto Ch<strong>an</strong>geover• Use With:3 – 10 Ton Precedent Units WSC12.5 – 20 Ton Voyager UnitsWCD\WCH• Heat/Auto/Off/Cool Switch• Auto/On F<strong>an</strong> Switch• Normal/Emergency Heat Switch• System On/Heat/Cool/ServiceIndicator Lights• Blue Cool/Red Heat Setpoint Levers• Vendor: Sunne (62824)• Finish: P<strong>an</strong>tone Cool Gray #2C• Replacement: SEN-0414• Installation – 18-HD60D37• Source: ClarksvilleBAYSENS017B• Remote Zone Sensor• Use With:BAYSENS006, 007, 008, 009, 010B,011B• Allows remote zone monitoring withst<strong>an</strong>dard electronic zone sensors• Vendor: Sunne (62828)• Finish: P<strong>an</strong>tone Cool Gray #2C• Replacement: SEN-0435• Installation – 18-HD60D41• Source: ClarksvilleIntegrated Comfort TM SystemsSensors For ReliaTel TM UnitsBAYSENS013C• Room Sensor with Timed Override• Use with Integrated Comfort TMSystems• Use With:3 – 10 Ton Precedent Units12.5 – 25 Ton Voyager Units• Timed Override Buttons• Vendor: Sunne (65464)• Finish: P<strong>an</strong>tone Cool Gray #2C• Replacement: SEN-0495• Installation – 18-HD60D38• Source: ClarksvilleBAYSENS014C• Room Sensor with SetpointAdjustment• Used with Integrated Comfort TMSystems• Use With:3 – 10 Ton Precedent Units12.5 – 25 Ton Voyager Units• Timed Override Buttons• Thumbwheel Setpoint• Vendor: Sunne (65465)• Finish: P<strong>an</strong>tone Cool Gray #2C• Replacement: SEN-0496• Installation – 18-HD60D39• Source: ClarksvilleCCZO-21 Effective 1/1/06


Ductless Air Conditioners• Low sound levels through improved f<strong>an</strong><strong>an</strong>d motor.• Precise Airflow through unique wide airdiffusion system.• Three stage air filter for improved IndoorAir Quality (IAQ).• Flexibility to be matched with 10 SEER<strong>an</strong>d 12 SEER condensing units.• Washable Grille.• Lightweight <strong>an</strong>d compact size.• Powerful mode for 20 minute maximumoutput.• Cooling, Dehumidify (Dry), <strong>an</strong>d F<strong>an</strong>-Only modesTable MINI-1-A – Ductless High Wall - Cooling OnlySound UncratedModel Nominal Level Dimensions(in.) ShippingNumber Airflow (L, H) H x W x D WeightMCW509AMUA 265 31, 36 10.8 x 30.9 x 7.3 17.6MCW512AMUA 310 31, 39 10.8 x 30.9 x 7.3 17.6MCW518AMUA 520 36, 43 11.8 x 41.3 x 7.5 26.4MCW524AMUA 525 38, 46 11.8 x 41.3 x 7.5 26.4MCW530AMUA 600 37, 41 14.2 x 61.8 x 7.9 59.5MCW536AMUA 800 41, 45 14.2 x 66.5 x 7.9 61.7Table MINI-1-B – Accessories – Remote Controller Options (MCW530 & MCW536)1Model Number Description H W DRAYSTAT020A ............ Wired Remote Controller ............... 4.8 ......... 4.8 ......... 0.7RAYSTAT021A ............ Wireless Remote Controller ........... 6.2 ......... 2.4 ......... 0.7Table MINI-1-C – Accessories – Exp<strong>an</strong>sion Device (Orifice) (All Sizes)1ModelModel UsedNumber Description With SizeBAYOFKT001 .... Metering Device (Orifice) ..... MCW512-18 ..... .043/.046BAYOFKT002 .... Metering Device (Orifice) ....... MCW524 ............ .047BAYOFKT003 .... Metering Device (Orifice) ....... MCW530 ............ .057BAYOFKT004 .... Metering Device (Orifice) ....... MCW536 ............ .063Table MINI-1-D – Accessories – Low Voltage Tr<strong>an</strong>sformer (All Sizes)1ModelModel UsedNumber Description WithBAYHVLV001 ...... 208-240/24V Tr<strong>an</strong>sformer ............ All1 Required for unit operation with TTB, 2TTB2 condensing units. Not required with TTK condensing units.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.MINI-1 Effective 1/1/06


Ductless Outdoor Units• 9000 Btu model available• Low sound levels• Reduced installation time• 10-12 SEER depending uponcapacity• Installation flexibilityTable MINI-2-A – Ductless Outdoor Unit - Cooling OnlyNom. Cap. Uncrated Line SizeModel Power Cooling Dimensions(in.) Shipping Sound Max OD ODNumber Supply (BTUH) H W D Weight Rating MCA* Fuse* Gas Liq.TTK509E5UA 208-230/1/60 9,000 20 28 10 66 53 6.6 10 3/8 1/4TTK512E5UA 208-230/1/60 12,000 20 28 10 77 53 7.3 12 1/2 1/4TTK518E5UA 208-230/1/60 18,000 29 33 13 121 58 11.7 20 1/2 1/4TTK524E5UA 208-230/1/60 24,000 29 33 13 141 62 14.5 25 5/8 1/4TTK530E5UA 208-230/1/60 30,000 29 33 13 163 62 21.5 35 5/8 3/8TTK536E5UA 208-230/1/60 36,000 29 33 13 168 64 26 45 3/4 3/8Table MINI-2-B – Optional Accessories:ModelModel UsedNumber Description WithBAYLOAMM001A Low Ambient Kit TTK509-512BAYLOAMM002A Low Ambient Kit TTK518-536Effective 1/1/06MINI-2For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Packaged TerminalAir Conditioners And Heat PumpsTable PTAC/UH-1-A — Packaged Terminal Air ConditionerPower Supply Cooling Cabinet ShippingChassis Volts/Phase/Hz Capacity EER kW H x W x D WeightPTED0701D*A 208-230/1/60 7,000 12.5 2.0 16 1 / 6 x 42 x 13 ¾ 102PTED0701G*A 208-230/1/60 7,000 12.5 3.5 16 1 / 6 x 42 x 13 ¾ 102PTED0701W*A 5 208-230/1/ 60 7,000 12.5 N/A 16 1 / 6 x 42 x 13 ¾ 102PTED0901D*A 208-230/1/ 60 9,000 11.6 2.0 16 1 / 6 x 42 x 13 ¾ 103PTED0901G*A 208-230/1/ 60 9,000 11.6 3.5 16 1 / 6 x 42 x 13 ¾ 103PTED0901W*A 5 208-230/1/ 60 9,000 11.5 N/A 16 1 / 6 x 42 x 13 ¾ 103PTED0902D*A 265/1/60 9,000 11.5 2.0 16 1 / 6 x 42 x 13 ¾ 103PTED0902G*A 265/1/60 9,000 11.5 3.7 16 1 / 6 x 42 x 13 ¾ 103PTED1201G*A 208-230/1/60 12,000 11.2 3.5 16 1 / 6 x 42 x 13 ¾ 109PTED1201J*A 208-230/1/60 12,000 11.2 5.0 16 1 / 6 x 42 x 13 ¾ 109PTED1201W*A 5 208-230/1/60 12,000 11.2 N/A 16 1 / 6 x 42 x 13 ¾ 109PTED1202G*A 265/1/60 12,000 11.2 3.7 16 1 / 6 x 42 x 13 ¾ 110PTED1501G*A 208-230/1/60 15,000 10.2 3.5 16 1 / 6 x 42 x 13 ¾ 117PTED1501J*A 208-230/1/60 15,000 10.2 5.0 16 1 / 6 x 42 x 13 ¾ 117PTED1501W*A 5 208-230/1/60 15,000 10.2 N/A 16 1 / 6 x 42 x 13 ¾ 117PTED1502G*A 265/1/60 15,000 10.0 3.7 16 1 / 6 x 42 x 13 ¾ 118Table PTAC/UH-1-B — Packaged Terminal Heat Pump with Electric HeatPower Supply Cooling Cabinet ShippingChassis Volts/Phase/Hz Capacity EER kW H x W x D WeightPTHD0701D*A 208-230/1/60 7,000 12.2 2.0 16 1 / 6 x 42 x 13 ¾ 102PTHD0701G*A 208-230/1/60 7,000 12.2 3.5 16 1 / 6 x 42 x 13 ¾ 102PTHD0901D*A 208-230/1/60 9,000 11.2 2.0 16 1 / 6 x 42 x 13 ¾ 109PTHD0901G*A 208-230/1/60 9,000 11.2 3.5 16 1 / 6 x 42 x 13 ¾ 109PTHD0902D*A 265/1/60 9,000 11.2 2.0 16 1 / 6 x 42 x 13 ¾ 109PTHD0902G*A 265/1/60 9,000 11.2 3.7 16 1 / 6 x 42 x 13 ¾ 109PTHD1201G*A 208-230/1/60 12,000 10.3 3.5 16 1 / 6 x 42 x 13 ¾ 110PTHD1201J*A 208-230/1/60 12,000 10.3 5.0 16 1 / 6 x 42 x 13 ¾ 110PTHD1202G*A 265/1/60 12,000 10.7 3.7 16 1 / 6 x 42 x 13 ¾ 110PTHD1501G*A 208-230/1/60 15,000 9.7 3.5 16 1 / 6 x 42 x 13 ¾ 110PTHD1501J*A 208-230/1/60 15,000 9.7 5.0 16 1 / 6 x 42 x 13 ¾ 118PTHD1502G*A 265/1/60 15,000 9.3 3.7 16 1 / 6 x 42 x 13 ¾ 118Notes:1 All units ship with cord <strong>an</strong>d plug.2 265 volt units require either a subbase or a hard wire junction box kit to be U.L. approved.3 All units are ARI listed, C.U.L. <strong>an</strong>d U.L. approved.4 All units include a cord with plug, unit mounted control, built in front desk control terminals (wiring kit is required) temperaturelimiter, room freeze protection, f<strong>an</strong> cycle switch, compressor time delay, cooling condensate removal <strong>an</strong>d automatic emergencyheat stage thermostat on all heat pumps. Also all units have a built-in switch to ch<strong>an</strong>ge operation from unit mounted control toremote, wall, mounted control.5 Hydronic units ship with no electric heat <strong>an</strong>d no plastic front cover. The hydronic kit, which must be ordered separately, includes ametal front cover.PTAC/UH-1 Effective 1/1/06


Packaged TerminalAir Conditioners And Heat PumpsTable PTAC/UH-2-A — AccessoriesDescription <strong>an</strong>d Usage SleevesSt<strong>an</strong>dard Wall SleeveExtended 18" Wall SleeveExtended 24" Wall SleeveOrder NumberWS130WS180WS240Note: To be ordered for all installations except where existing wall sleeves are used.Drain KitDRAINNote: Attaches to wall sleeve for controlled indoor or outdoor disposal of condensate to a field supplied drain system.GrillesStamped Aluminum Grille - Single PackSAG01Stamped Aluminum Grilles - Ten PackSAG10Architectural Aluminum Grille - Anodized finishAAGALArchitectural Aluminum Grille - Dark BronzeAAGDBArchitectural Aluminum Grille - Soft DoveAAGSDWall Sleeve Levelling LegsLVLG02Note: Used when a subbase is not required, but, additional support <strong>an</strong>d leveling is needed. The adjusting screw c<strong>an</strong> be extended 2 inches with a maximumdist<strong>an</strong>ce from the bottom of the wall sleeve to screw base of 5 inches <strong>an</strong>d a minimum dist<strong>an</strong>ce of 3 inches.SubbasesSubbase 230/208V, 20ASUB0120Subbase 230/208V, 30ASUB0130Subbase 265V, 20ASUB0220Subbase 265V, 30ASUB0230Note: Provides a space to tie into building wiring <strong>an</strong>d also includes a receptacle to plug unit into. Gives additional leveling <strong>an</strong>d support capabilities. Provides aplace for fuses, circuit breaker or mech<strong>an</strong>ical disconnect to be mounted.Power or Mech<strong>an</strong>ical Disconnect SwitchPower Switch 230/208V, 30 APS0130Power Switch 265V, 30 APS0230Note: These above kits c<strong>an</strong> be installed on hard wire junction box <strong>an</strong>d provides a way to shut unit on <strong>an</strong>d off. Check local codes for approval.Circuit Breaker KitsCircuit Breaker 15ACB0115Circuit Breaker 20ACB0120Circuit Breaker 30ACB0130Note: The Circuit Breaker Kit c<strong>an</strong> be installed on front of subbase <strong>an</strong>d provides overcurrent protection <strong>an</strong>d me<strong>an</strong>s of shutting unit on <strong>an</strong>d off.Control P<strong>an</strong>el Key LockKEYLOKNote: To prevent unauthorized access to unit control p<strong>an</strong>el.Fuse Holder KitsFuse Holder Kit 15AFUSE0115Fuse Holder Kit 20AFUSE0120Fuse Holder Kit 30AFUSE0130Note: Cartridge fuse fits into receptacle with screw type cap. Installed at unit control p<strong>an</strong>el or in subbase. Provides overcurrent protection.Hard Wire KitHWIREKNote: This kit provides convenient space to make electrical connection to building wiring. Includes flexible conduit, <strong>an</strong>d wire to make connection from unitchassis.Hydronic Chassis OptionPlastic Front CoverPFC01Note: Use with hydronic chassis when hot water kit is not used.Effective 1/1/06PTAC/UH-2


Packaged TerminalAir Conditioners And Heat PumpsTable PTAC/UH-3-A — AccessoriesHydronic KitsHydronic Steam Heat Kit - 230/208VHydronic Steam Heat Kit - 265VHydronic Steam Heat Kit - 115VHydronic Water Heat Kit - 115VHydronic Water Heat Kit - 265VHydronic Water Heat Kit - 230/208VOrder NumberHSK01HSK02HSK04HWK04HWK02HWK01Note: Hydronic kits are to be ordered with the hydronic heat chassis only. Kits come with valve <strong>an</strong>d tr<strong>an</strong>sformer.Note: All valves for Hydronic <strong>an</strong>d Steam are 24 volt <strong>an</strong>d include <strong>an</strong> end switch.Digital Wall Mounted Thermostats1H/1C Digital Prog Tstat (4-wire Pwr Steal)TAYSTAT3401H/1C Digital NonProg Tstat (4-wire Pwr Steal) TAYSTAT3712H/1C Heat Pump Digital Prog TstatTAYSTAT5402H/1C Heat Pump Digital NonProg TstatTAYSTAT570Note: All Wall Mounted Thermostats will work with st<strong>an</strong>dard units. All units include a switch for ch<strong>an</strong>ging from unit mounted operation to remote or wallmounted operation. See notes for AUXWIRE.Wire Harness Kit - 10 PackAUXWIRENote: Required when Wall Mounted Thermostat or Zone Sensor is used.Remote Zone SensorZONSENSNote: This temperature sensor overrides st<strong>an</strong>dard unit mounted thermostat to allow temperature sensing on internal wall for more accurate temperaturecontrol.Remote Escutcheon Kits - 10 PackREK10CNote: This kit should be ordered whenever Wall Thermostats are ordered. This Kit includes a control cover plate, that will cover the normal unit mountednomenclature. This kit comes 10/pack. A wire harness kit should be ordered separate.Condensate PumpsCondensate Pump 230/208VCDP01Condensate Pump 265VCDP02Note: This kit is for Heat Pumps ONLY <strong>an</strong>d includes a small pump that will remove condensate developed during the heat pump operation <strong>an</strong>d tr<strong>an</strong>sfer it tothe indoor coil for re-evaporation <strong>an</strong>d to dissipate into the room, adding humidity to the room. This option c<strong>an</strong>not be used with Corrosion-Resist<strong>an</strong>t Models.This c<strong>an</strong> be field installed but it is very time-consuming <strong>an</strong>d it is our recommendation that you choose the factory installed option. Import<strong>an</strong>t, even with thisoption if no overflow of condensate is permissible, the installation of <strong>an</strong> external or building internal drain system is recommended.Spare Filters - 10 PackFILTR10Note: Using the field installed, perm<strong>an</strong>ent, cle<strong>an</strong>able filters will keep debris off of the coil <strong>an</strong>d out of the air. Unit will operate more efficiently if filters arech<strong>an</strong>ged regularly.PTAC/UH-3 Effective 1/1/06


Indoor Gas Heating ProductsProduct Description Indoor UnitsPropeller F<strong>an</strong> Gas Unit Heater• Two-point Suspension• Horizontal Louvers• 115/60/1 Open Drip-proof Motor withBuilt-in T.O.P.• 24V Control Tr<strong>an</strong>sformer• Junction Box for Power Wiring• Single-Stage Automatic Gas Valve• St<strong>an</strong>ding Pilot• F<strong>an</strong> Time Delay Relay• Aluminized Steel Heat Exch<strong>an</strong>ger• Blocked Vent (Spill) Switch• “10 Year Non-Prorated Warr<strong>an</strong>ty” onthe Heat Exch<strong>an</strong>ger, Burners <strong>an</strong>dDraft Hood Assembly.High Efficiency Propeller F<strong>an</strong> GasUnit Heater• Two-point Suspension• Horizontal Louvers• 115/60/1 Open Drip-proof Motor withBuilt-in T.O.P.• 24V Control Tr<strong>an</strong>sformer• Junction Box for Power Wiring• Single-Stage Combination Gas Valve• Intermittent Pilot Ignition• F<strong>an</strong> Time Delay Relay• Aluminized Steel Heat Exch<strong>an</strong>ger• Factory Installed Flue Vent F<strong>an</strong>• Combustion Air Pressure SwitchCentrifugal F<strong>an</strong> Gas Unit Heater• Horizontal Louvers• 115/60/1 Open Drip-proof Motor withBuilt-in T.O.P.• Adjustable V-belt Drive With Belt Guard• 24V Control Tr<strong>an</strong>sformer• Junction Box for Power Wiring• Single-Stage Automatic Gas Valve• St<strong>an</strong>ding Pilot• F<strong>an</strong> Time Delay Relay• Aluminized Steel Heat Exch<strong>an</strong>ger• Blocked Vent (Spill) Switch• “10 Year Non-Prorated Warr<strong>an</strong>ty” onthe Heat Exch<strong>an</strong>ger, Burners <strong>an</strong>dDraft Hood Assembly.• “10 Year Non-Prorated Warr<strong>an</strong>ty” onthe Heat Exch<strong>an</strong>ger, Burners <strong>an</strong>dDraft Hood Assembly.Contact Macon Product Support for moreinformation on these products (1-800-322-6495)Effective 1/1/06PTAC/UH-4The State of California requires a steady-state efficiency of 80% forboth indoor <strong>an</strong>d outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.


Indoor Gas Heating ProductsProduct Description Indoor UnitsHigh Efficiency Centrifugal F<strong>an</strong> GasUnit Heater• Horizontal Louvers• 115/60/1 Open Drip-proof Motor withBuilt-in T.O.P.• F<strong>an</strong> Guard• 24V Control Tr<strong>an</strong>sformer• Junction Box for Power Wiring• Single-Stage Intermittent Pilot Ignition• F<strong>an</strong> Time Delay Relay• Aluminized Steel Heat Exch<strong>an</strong>ger• Factory Installed Flue Vent F<strong>an</strong>• Combustion Air Pressure Switch• “10 Year Non-Prorated Warr<strong>an</strong>ty”on the Heat Exch<strong>an</strong>ger, Burners<strong>an</strong>d Draft Hood Assembly.Indoor Gas Duct Furnace• Blow Through Applications Only!• 24V Control Tr<strong>an</strong>sformer• Junction Box For Power Wiring• Single-Stage Automatic Gas Valve• St<strong>an</strong>ding Pilot• Aluminized Steel Heat Exch<strong>an</strong>ger• 10 year warr<strong>an</strong>ty “does not apply.”<strong>Tr<strong>an</strong>e</strong>’s st<strong>an</strong>dard 12/18 month only.• Blocked Vent (Spill) SwitchNote: A drain p<strong>an</strong> is not included.See field installed options.High Efficiency Indoor Gas DuctFurnace• Blow Through Applications Only• 24V Control Tr<strong>an</strong>sformer• Junction Box For Power Wiring• Single-Stage Combination Gas Valve• Intermittent Pilot Ignition• Aluminized Steel Heat Exch<strong>an</strong>ger• Factory Installed Flue Vent F<strong>an</strong>• Combustion Air Pressure Switch• 10 year warr<strong>an</strong>ty “does not apply.”<strong>Tr<strong>an</strong>e</strong>’s st<strong>an</strong>dard 12/18 month only.Note: A drain p<strong>an</strong> is not included.See field installed options.Horizontal Blower Assembly• Junction Box For Power Wiring• Filter Rack <strong>an</strong>d 1” Perm<strong>an</strong>ent Filters• Adjustable V-Belt Drive• 10 year warr<strong>an</strong>ty “does not apply.”<strong>Tr<strong>an</strong>e</strong>’s st<strong>an</strong>dard 12/18 month only.The State of California requires a steady-state efficiency of 80% forboth indoor <strong>an</strong>d outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.Contact Macon Product Support for moreinformation on these products (1-800-322-6495)PTAC/UH-5 Effective 1/1/06


Indoor Gas Heating ProductsIndoor UnitsTable PTAC/UH-6-A — Propeller F<strong>an</strong> Gas Unit HeatersUnit Size 003 004 006 007 010 012 015 017 020 022 025 030 035 040MBh (input) 30 45 60 75 100 125 150 175 200 225 250 300 350 400MBh (output) 24.3 36.5 48.6 60.8 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0Propeller F<strong>an</strong> AlumUnit Heater 409SSGPND or GPPD 321SS — — — —Std. 115/60/1 motor hp 1/30 1/30 1/30 1/30 1/20 1/10 1/4 1/3 1/3 1/3 1/3 (2)1/4 (2)1/3 (2)1/3Notes:Approved in California when ordered with intermittent pilot ignition.Table PTAC/UH-6-B — High Efficiency Propeller F<strong>an</strong> Unit HeaterUnit Size 003 004 006 007 010 012 015 017 020 022 025 030 035 040MBh (input) 30 45 60 75 100 125 150 175 200 225 250 300 350 400MBh (output) 24.9 37.4 48.0 60.0 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0High Eff Prop AlumF<strong>an</strong> U.H. 409SSGHND or GHPD 321SS — — — —Std 115/60/1 motor hp 1/30 1/30 1/30 1/30 1/20 1/10 1/4 1/3 1/3 1/3 1/3 (2)1/4 (2)1/3 (2)1/3Notes:1. The only gas control option available is single stage intermittent pilot. This is included in the list price of the unit.2. 115V flue vent f<strong>an</strong>s are factory installed <strong>an</strong>d included in the list price of the unit.Table PTAC/UH-6-C — Separated Combustion Propeller F<strong>an</strong> Gas Unit HeaterUnit Size 010 012 015 017 020 022 025 030 035 040MBh (input) 100 125 150 175 200 225 250 300 350 400MBh (output) 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0Sep. Comb. AlumF<strong>an</strong> U.H.409SSGAND or GAPD 321SSStd 115/60/1 motor hp 1/20 1/10 1/4 1/3 1/3 1/3 1/3 (2) 1/4 (2) 1/3 (2) 1/3Notes:1. Single stage intermittent pilot ignition is st<strong>an</strong>dard <strong>an</strong>d included in the list price of the unit. Two-stage intermittent pilot is available as <strong>an</strong> option.2. 115V factory installed flue vent f<strong>an</strong> is included in the list price of the unit.Table PTAC/UH-6-D — Centrifugal F<strong>an</strong> Gas Unit HeatersUnit Size 010 012 015 017 020 022 025 030 035 040MBh (input) 100 125 150 175 200 225 250 300 350 400MBh (output) 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0Centrifugal F<strong>an</strong> AlumUnit Heater 409SSGCND or GCPD 321SSStd 115/60/1 motor hp 1/4 1/3 1/2 1/2 3/4 3/4 3/4 3/4 1 1Notes:1. Includes st<strong>an</strong>dard 115/60/1 open drip-proof motor.2. If other th<strong>an</strong> st<strong>an</strong>dard voltage required, deduct st<strong>an</strong>dard motor <strong>an</strong>d add required motor.3. Contact Macon Product Support if motor size other th<strong>an</strong> st<strong>an</strong>dard size is required.4. Approved in California when ordered with intermittent pilot ignition.5. If ordering a flue vent f<strong>an</strong> (460V units) add tr<strong>an</strong>sformer list add shown in flue vent f<strong>an</strong> table.Contact Macon Product Support for moreinformation on these products (1-800-322-6495)Effective 1/1/06PTAC/UH-6The State of California requires a steady-state efficiency of 80% forboth indoor <strong>an</strong>d outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.


Indoor Gas Heating ProductsIndoor UnitsTable PTAC/UH-7-A — High Efficiency Centrifugal F<strong>an</strong> Gas Unit HeaterUnit Size 010 012 015 017 020 022 025 030 035 040MBh (input) 100 125 150 175 200 225 250 300 350 400MBh (output) 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0High Eff. Cent. AlumF<strong>an</strong> U.H.409SSGBND or GBPD 321SSSt. 115/60/1 motor hp 1/4 1/3 1/2 1/2 3/4 3/4 3/4 3/4 1 1Notes:1. Includes st<strong>an</strong>dard 115/60/1 open drip-proof motor.2. If other th<strong>an</strong> st<strong>an</strong>dard voltage is required, deduct st<strong>an</strong>dard motor <strong>an</strong>d add required motor.3. 115V flue vent f<strong>an</strong>s are st<strong>an</strong>dard <strong>an</strong>d included. If other th<strong>an</strong> st<strong>an</strong>dard voltage is required, include a Line/115V tr<strong>an</strong>sformer.4. Contact Macon Product Support, if motor size other th<strong>an</strong> st<strong>an</strong>dard is required.Table PTAC/UH-7-B — Separated Combustion Centrifugal F<strong>an</strong> Gas Unit HeaterUnit Size 010 012 015 017 020 022 025 030 035 040MBh (input) 100 125 150 175 200 225 250 300 350 400MBh (output) 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0Sep. Comb. Cent. AlumF<strong>an</strong> U.H.409SSGKND or GKPD 321SSStd 115/60/1 motor hp 1/4 1/3 1/2 1/2 3/4 3/4 3/4 3/4 1 1Notes:1. Includes st<strong>an</strong>dard 115/60/1 open drip-proof (ODP) motor.2. If other th<strong>an</strong> st<strong>an</strong>dard voltage is required, deduct st<strong>an</strong>dard motor <strong>an</strong>d add required motor.3. Includes single-stage intermittent pilot ignition <strong>an</strong>d a 115V factory installed flue vent f<strong>an</strong>. If other th<strong>an</strong> st<strong>an</strong>dard voltage is required, include a line/115V tr<strong>an</strong>sformer.4. Two-stage intermittent pilot ignition is available as <strong>an</strong> option.5. Contact Macon Product Support if motor size other th<strong>an</strong> st<strong>an</strong>dard is required.Table PTAC/UH-7-C — Indoor Gas Duct FurnacesUnit Size 010 012 015 017 020 022 025 030 035 040MBh (input) 100 125 150 175 200 225 250 300 350 400MBh (output) 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0Indoor Duct AlumFurnace409SSGDND or GDPD 321SSNotes:Duct Furnaces are approved only in blow-thru applications.If a duct furnace is being used with <strong>an</strong> HBAC — the main power supply must be the same. The duct furnace includes a Line to 24V control tr<strong>an</strong>sformer.Table PTAC/UH-7-D — High Efficiency Gas Duct FurnacesUnit Size 010 012 015 017 020 022 025 030 035 040MBh (input) 100 125 150 175 200 225 250 300 350 400MBh (output) 80 100 120 140 160 180 200 240 280 320High Eff Indoor AlumDuct Furnace 409SSGLND or GLPD 321SSNotes:1. Includes single-stage intermittent pilot.2. Includes 115/24V control tr<strong>an</strong>sformer. No other voltage selection available.3. 115V flue vent f<strong>an</strong>s are factory installed.4. Approved in the blow-thru applications only.The State of California requires a steady-state efficiency of 80% forboth indoor <strong>an</strong>d outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.Contact Macon Product Support for moreinformation on these products (1-800-322-6495)PTAC/UH-7 Effective 1/1/06


Indoor Gas Heating ProductsIndoor UnitsTable PTAC/UH-8-A — Separated Combustion Duct FurnacesUnit Size 010 012 015 017 020 022 025 030 035 040MBh (input) 100 125 150 175 200 225 250 300 350 400MBh (output) 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 260.0 320.0Sep. Comb. AlumDuct Furnace 409SSGMND or GMPD 321SSNotes:1. Includes single-stage intermittent pilot.2. Includes 115/24V control tr<strong>an</strong>sformer. No other voltage selection available.3. 115V flue vent f<strong>an</strong>s are factory installed.4. Approved in the blow-through applications only.Table PTAC/UH-8-B— Tubular Heat Exch<strong>an</strong>ger, Propeller Gas Unit HeaterUnit Size 003 004 006 007 009 010 012 015 017 020 025 030 035 040MBh (input) 30 45 60 75 90 100 125 150 175 200 250 300 350 400MBh (output) 24.3 36.5 48.6 60.8 72.9 81.0 101.3 121.5 141.7 162.0 202.5 243.0 283.5 324.0Tubular Heat Exc. AlumGTND or GTPDStd. 115/60/ motor hp 1/20 1/20 1/20 1/20 1/20 1/10 1/4 1/4 1/3 1/3 1/3 1/4 1/3 1/3Notes:1. Units only available with Aluminized Heat Exch<strong>an</strong>ger, stainless steel not available or required.2. Factory installed flue vent f<strong>an</strong> is included.3. The gas control is single stage, hot surface pilot ignition <strong>an</strong>d is included in the unit.4. Size 225 MBh units are not available.Table PTAC/UH-8-C — Tubular Heat Exch<strong>an</strong>ger - <strong>Residential</strong> Propeller F<strong>an</strong> Gas Unit HeaterUnit Size R03 R04 R06 R07 R09MBh (input) 30 45 60 75 90MBh (output) 24.3 36.5 48.6 60.8 72.9Tubular - <strong>Residential</strong> AlumGTND or GTPDStd. 115/60/1 motor hp 1/20 1/20 1/20 1/20 1/20Notes:1. Includes st<strong>an</strong>dard 115/60/1 open drip-proof (ODP) motor. If totally enclosed 115/60/1 motors are required.2. Units only available with Aluminized Heat Exch<strong>an</strong>ger, stainless steel not available or required.3. Factory installed flue vent f<strong>an</strong> is included.4. The only gas control option available is single stage, hot surface pilot ignition. This is included in the unit.5. Includes spil or flame roll out switch.6. Includes OSHA F<strong>an</strong> Guard.Table PTAC/UH-8-D — Horizontal Blower AssemblyHorizontal Unit Size 15 20 030 045Blower Duct Furnace Size Used With 010, 012 015, 017 020, 022, 025 030, 035, 040Assembly Unit —HBAC Tr<strong>an</strong>sition 48 48 48 48Note:Does not include motor. Motor from Table PTAC/UH-9-A must be added to unit.Contact Macon Product Support for moreinformation on these products (1-800-322-6495)Effective 1/1/06PTAC/UH-8The State of California requires a steady-state efficiency of 80% forboth indoor <strong>an</strong>d outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.


Indoor Gas Heating ProductsIndoor Unit Options(Factory Installed)Table PTAC/UH-9-A —Motor PricesVoltage 1/4 hp 1/3 hp 1/2 hp 3/4 hp 1 hp 1-1/2 hp 2 hp115/60/1 - Open230/60/1 - Open208/60/3 - Open —230/60/3 - Open —460/60/3 - Open —575/60/3 - Open — —115/60/1 - T.E.230/60/1 - T.E.208/60/3 - T.E. —230/60/3 - T.E. —460/60/3 - T.E. —575/60/3 - T.E. — —Shipping Wt. 51 55 55 57 57 75 88motor prices — for totally enclosed motors for Propeller F<strong>an</strong> Unit Heaters only <strong>an</strong>d Tubular UnitsVoltage 1/3 hp 1/20 hp 1/10 hp 1/4 hp 1/3 hp 1/4 hp 1/3 hpUnit sizes 003 004 006 007 10 12 15 017 020 022 025 30 035 040R03, R04, R06, R07, R09115/60/1Note:Contactors not required on <strong>an</strong>y units provided with single phase motors up to 1 hp. Low voltage contactors are included on all units with single phase 1 1 /2 hp <strong>an</strong>d above motors <strong>an</strong>don all three-phase motors.Table PTAC/UH-9-B —Gas Control OptionsPilot — Gas Type Control DesignatorSt<strong>an</strong>dard St<strong>an</strong>ding Pilot — Single-Stage A**Propeller, Duct <strong>an</strong>d Natural or LP (Prop<strong>an</strong>e) Gas Hydraulic Modulating 1 CCentrifugal Units Only Intermittent Pilot — Single-Stage D(GP, GC, GD) Natural or LP (Prop<strong>an</strong>e) Two-Stage 4 EGas Hydraulic Modulating 1,4 FHydraulic Modulating w/Bypass 1,4 GIntermittent — Pilot — Electronic Modulating — Room Stat HNatural or LP (Prop<strong>an</strong>e) Gas Electronic Modulating — Duct Stat 5 JElectronic Modulating w/ExternalL4-20 mA InputElectronic Modulating w/ExternalN0-10 VDC InputHigh Efficiency Intermittent Pilot Single-Stage D**Units — Propeller, Natural or LP (Prop<strong>an</strong>e) Gas Two-Stage 4 ECentrifugal <strong>an</strong>d Duct Hydraulic Modulating 1,4 FFurnaces Only Hydraulic Modulating w/Bypass 1,4 G(GH, GB, GL) Intermittent Pilot — Electronic Modulating — Room Stat 4 HNatural or LP (Prop<strong>an</strong>e) Gas Electronic Modulating — Duct Stat 4, 5 JElectronic Modulating w/ExternalL4-20 mA InputElectronic Modulating w/ExternalN0-10 VDC InputSeparated Intermittent Pilot — Single-Stage DCombustion Units Natural or LP (Prop<strong>an</strong>e) Two-Stage EIntermittent Pilot — Electronic Modulating — Room Stat 4 HNatural or LP (Prop<strong>an</strong>e) Gas Electronic Modulating — Duct Stat 4, 5 JElectronic Modulating w/ExternalL4-20 mA InputElectronic Modulating w/ExternalN0-10 VDC InputTubular Heat Exch<strong>an</strong>ger Units Hot surface pilot ignition Single-Stage KTubular Heat Exch<strong>an</strong>ger Units Hot surface pilot ignition Two-Stage ENotes:1. Specify discharge temperature in the body of the order. Two hydraulic modulating valves are offered. One valve has a r<strong>an</strong>ge of 60-100 degrees. The other valve has a r<strong>an</strong>ge of75-200°. If no temperature is specified, the 60-100 r<strong>an</strong>ge will ship. N/A on sizes 003-007.2. For elevations over 4000 ft., hydraulic modulating is not available.3. Units for California shipment require intermittent pilot ignition.4. Not available on sizes 003-007. These sizes are AGA approved on single stage gas controls only. Two-stage control is available up to 7,500 ft. elevation. Over 7500 ft., singlestage only.5. Only available on duct unit heaters or centrifugal with duct discharge fl<strong>an</strong>ge option.** Not available.The State of California requires a steady-state efficiency of 80% forboth indoor <strong>an</strong>d outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.Contact Macon Product Support for moreinformation on these products (1-800-322-6495)PTAC/UH-9 Effective 1/1/06


Indoor Gas Heating ProductsIndoor Unit Options(Factory Installed)Table PTAC/UH-10-A — Miscell<strong>an</strong>eous OptionsAvailable On Option DesignatorAll Gas Special Orifices B**Heating Units 3 Summer-Winter Switch* DCentrifugal F<strong>an</strong> Unit Heaters Duct Discharge Fl<strong>an</strong>ge 1 H**Indoor Duct F<strong>an</strong> Time Delay Control LFurnaces Side Access Burner Drawer 2 KHoriz. Blower Assembly Motor 3 See Table PTAC/UH-9-ANotes:* When used with a duct furnace, optional f<strong>an</strong> time delay control must be ordered.1. Not required when nozzles are ordered.2. St<strong>an</strong>dard side access is on the left side as the airflow is blowing in your face. Opposite from st<strong>an</strong>dard c<strong>an</strong> be ordered as a special. Contact Macon Product Support.3. Not available on Tubular Heat Exch<strong>an</strong>ger units.** Not available.Contact Macon Product Support for moreinformation on these products (1-800-322-6495)Effective 1/1/06PTAC/UH-10The State of California requires a steady-state efficiency of 80% forboth indoor <strong>an</strong>d outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.


Indoor Gas Heating ProductsIndoor Unit Accessories(Factory Installed)Table PTAC/UH-11-A— Miscell<strong>an</strong>eous OptionsUnit Size 003 004 006 007 010 012 015 017 020 022 025 030 035 040MBhAvailable On Option Des 30 45 60 75 100 125 150 175 200 225 250 300 350 400409 S.S. Burners A — — — —All Units 1409 S.S. FlueCollector/Draft Diverter C — — — —Vertical Louvers E — — — —Horiz. Louvers F — — — —Indoor Horiz. & VerticalDuct Furnaces Louvers G — — — —Unit Size 32 42 62 94Horiz. Blower Insul. for BlowerAssembly & Tr<strong>an</strong>sition 1Available on Unit Size 003 004 006 007 010 012 015 017 020 022 025 030 035 040Propeller F<strong>an</strong>,MBhHigh Efficiency Option Des 30 45 60 75 100 125 150 175 200 225 250 300 350 400Propeller F<strong>an</strong> OSHA F<strong>an</strong> Guards 7<strong>an</strong>d TubularHeat Exch<strong>an</strong>gerSeparated OSHA F<strong>an</strong> Guards 7 — — — —CombustionPropeller F<strong>an</strong> UnitsNote:1. 409 S.S. Burners, 409 S.S. Flue Collector/Draft Diverter <strong>an</strong>d Vertical Louvers are not available on Tubular Heat exch<strong>an</strong>ger units.The State of California requires a steady-state efficiency of 80% forboth indoor <strong>an</strong>d outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.Contact Macon Product Support for moreinformation on these products (1-800-322-6495)PTAC/UH-11 Effective 1/1/06


Indoor Gas Heating ProductsIndoor Unit Accessories(Field Installed)Table PTAC/UH-12-A—Flue Vent F<strong>an</strong>sFlue Vent F<strong>an</strong> Thermostat 4 Unit 003 004 006 007 010 012 015 017 020 022 025 030 035 040Power Supply Size 30 45 60 75 100 125 150 175 200 225 250 300 350 400115/60/1 Ordering NoLow 350-0019- 01 02 04 05 06 07 08 09 10 11 12 13 14 151List Price208/60/1 Order NoLow 350-0019- — — — 17 18 19 20 21 22 23 24 25 26 272List Price230/60/1 Order NoLow 350-0019- — — — 29 30 31 32 33 34 35 36 37 38 393List PriceNotes:All flue vent f<strong>an</strong>s provided with adaptor for unit mounting.1. For use with units with 115/60/1 main power supply.2. For use with units with 208/60/1 or 208/60/3 main power supply.3. For use with units with 230/60/1, 230/60/3, 460/60/3, or 575/60/3 main power supply. Order should specify when for use with units with 460/60/3 or 575/60/3 main power supply, a460/230V tr<strong>an</strong>sformer is required.4. Flue vent f<strong>an</strong>s for use with low voltage thermostats are provided with a relay with 24V holding coil.5. Flue vent f<strong>an</strong>s are st<strong>an</strong>dard 115V on GHPD, GHND, GBPD, GBND, GLND, GLPD, GAND, GAPD, GKND, GKPD, GMND, GMPD, GTND,GTPD units <strong>an</strong>d included in the unit. Do notorder separately.Table PTAC/UH-12-B—Miscell<strong>an</strong>eous AccessoriesAvailable On Option Pipe Size Order No 350-Natural GasHigh Gas LineHeating Units Pressure Regulator (See Note) 3/4” NPT 0015-20Notes:When high gas line pressure regulators are ordered you must specify the pressure at the job. This is required so the factory c<strong>an</strong> select the regulator to accommodate thespecific pressure at the job. More th<strong>an</strong> one unit c<strong>an</strong> be run from one regulator, however, we recommend that each unit have its own regulator. See orifice chart thatfollows. N/A requires local purchase of regulator.When ordered separate, must include model <strong>an</strong>d size of unit.Orifice Chart: Rockwell 043-182 RegulatorInlet Capacity in MBh for Natural GasSpringPressure 25-200 225-300 350-500 600 700 800 Required1 psi 3/8” — — — — — Blue (only)2 3/8” 3/8” — — — — Blue (only)3 3/8” 3/8” 3/8” — — — Blue or Green5 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” Blue or Green10 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” Blue or Green20 1/4” 1/4” 1/4” 1/4” 1/4” 5/16” Blue or Green40 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” Blue or Green60 1/8” 1/8” 1/8” 1/8” 1/8” 3/16” Blue or Green80 1/8” 1/8” 1/8” 1/8” 1/8” — Blue or Green100 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” Blue or Green125 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” Blue or GreenContact Macon Product Support for moreinformation on these products (1-800-322-6495)Effective 1/1/06PTAC/UH-12The State of California requires a steady-state efficiency of 80% forboth indoor <strong>an</strong>d outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.


Indoor Gas Heating ProductsIndoor Unit Accessories(Factory Installed)Table PTAC/UH-13-A—Miscell<strong>an</strong>eous AccessoriesUnit Size 010 012 015 017 020 022 025 030 035 040Available On Option Unit MBh 100 125 150 175 200 225 250 300 350 400All Units 6 Y Splitter Ordering NoDischarge 350-0018- 03 04 05 06 07 08 09 10 11 12Nozzle 1 List Price90° Downward Ordering NoDischarge 350-0018- 27 28 29 30 31 32 33 34 35 36Nozzle 1,4 List Price30° Downward Ordering NoDischarge 350-0018 65 45 46 47 48 49 50 51 52 53Nozzle 1,4 List Price60° Downward Ordering NoDischarge 350-0018 68 54 55 56 57 58 59 60 61 62Nozzle 1,4 List PriceOrdering NoOnly Drain P<strong>an</strong> 5 350-0076- 03 04 05 06 07 08 09 10 11 12Indoor (Al Steel) List PriceDuct Furnaces, &Ordering NoHi Eff. Drain P<strong>an</strong> 5 350-0076- 15 16 17 18 19 20 21 22 23 24not Sep. Comb. (409 SS) List PriceUnit Size 15 20 30 45Horiz. BlowerOrdering NoAssembly 1” TA Filter 350-0050- 01 01 03 05Set List Price1” Perm Filter Ordering NoSet 350-0050- 02 02 04 06(Std on HBAC) List PriceUnit Size 003 004 006 007 010 012 015 017 020 022 025 030 035 040Option Unit MBh 30 45 60 75 100 125 150 175 200 225 250 300 350 400Available on OSHA Ordering NoPropeller F<strong>an</strong>, F<strong>an</strong> 350-0154- 01 01 02 02 02 02 02 04 04 04 04 03 05 05High Efficiency Guards List PricePropeller F<strong>an</strong> <strong>an</strong>dTubular HeatExch<strong>an</strong>ger UnitsSeparated OSHA Ordering No.Combustion F<strong>an</strong> 350-0154- — — — — 02 02 02 04 04 04 04 03 05 05Propeller F<strong>an</strong> Units Guards List PriceNotes:1. Available on all indoor units 100-400 MBh.2. Only available on Duct Furnaces <strong>an</strong>d Centrifugal F<strong>an</strong> Unit Heaters.3. When nozzles are ordered separate from the unit, specify unit type. High efficiency units have different nozzle configurations th<strong>an</strong> st<strong>an</strong>dard units.4. 60° nozzles are two 30° <strong>an</strong>d 90° nozzles are three 30° nozzles. All nozzles ship unassembled.5. Recommended when used downstream of a cooling coil.6. If unit has (E) vertical louvers <strong>an</strong>d nozzles are ordered, vertical louvers not needed because vertical louvers are on nozzles.The State of California requires a steady-state efficiency of 80% forboth indoor <strong>an</strong>d outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.Contact Macon Product Support for moreinformation on these products (1-800-322-6495)PTAC/UH-13 Effective 1/1/06


Indoor Gas Heating ProductsIndoor Unit Accessories(Field Installed)Table PTAC/UH-14-A— Vent Caps <strong>an</strong>d Adapters (Reducers or Increasers)Unit Size 003 004 006 007 010 012 015 017 020 022 025 030 035 040Available on all Option Unit MBh 30 45 60 75 100 125 150 175 200 225 250 300 350 400High Efficiency <strong>an</strong>d 4” Ordering NoSeparated Vent Cap 0350-0155- 01 01 01 01 01 01 01 01 — — — — — —Combustion Units<strong>an</strong>d Tubular Heat 5” Ordering NoExch<strong>an</strong>ger Units Vent Cap 0350-0157- — — — — — — — — 01 01 01 — — —6” Ordering NoVent Cap 0350-0158- — — — — — — — — — — — 01 01 015” to 4” Ordering NoReducer 0350-0156- 01 01 01 01 01 01 01 01 — — — — — —5 to 6” Ordering NoIncreaser 0350-0159- — — — — — — — — — — — 01 01 01Notes:1. These are m<strong>an</strong>datory, for the C<strong>an</strong>adi<strong>an</strong> market, per the National St<strong>an</strong>dard of C<strong>an</strong>ada section B149, 1M91 for category 3 venting: (III). Use Certified venting system providedby (M<strong>an</strong>ufacturer).2. Tubular heat exch<strong>an</strong>ger units do not require reducers or increasers.Table PTAC/UH-14-B— ThermostatsType Voltage R<strong>an</strong>ge Order No 350-Single Stage Room Low (24V) 55 - 95°F 0015-01Duct Low (24V) 55 - 175°F 0015-07Single Stage* Room with Summer Winter Switch 2 Low (24V) 55 - 95°F 0015-02Room with Summer Winter Switch 2 Low (24V) 45 - 85°F 0015-03Two Stage Duct Low (24V) 55 - 175°F 0015-08Electronic Room Low (24V) 60 - 85°F Included in GasModulating Duct Low (24V) 65 - 85°F Control Option PriceOverride Room (for use with duct) Line 115V 50 - 90°F 0015-05Universal Guard for Room Thermostats 0015-06Notes:*When used with a duct furnace, optional f<strong>an</strong> time delay control must be ordered.1. Two-stage room thermostat with F<strong>an</strong> Auto-On Switch <strong>an</strong>d System Off-Auto Switch.2. Summer/winter switch does not lock out the heat.3. The only Thermostats available for Tubular heat exch<strong>an</strong>ger units are Single Stage Room, Order No. 0350-0015-01 <strong>an</strong>d Single Stage Room W/Summer Winter Switch, OrderNo. 0350-0015-02.Table PTAC/UH-14-C— Concentric Vent TerminalsAvailable On Option Ordering No.Separated Combustion Vertical Concentric Vent Kit 1 0350-0151-01Units ONLY Horizontal Concentric Vent Kit 2 0350-0152-01Notes:1. Kit includes 5” cap with special attached nonrecirculation disc, special 8” cap with 5” hole <strong>an</strong>d concentric vent box.2. Kit includes 5” cap with special attached nonrecirculation disc, inlet air screen <strong>an</strong>d concentric vent box.Table PTAC/UH-14-D— Vertical Louver Kits (Propeller <strong>an</strong>d Centrifugal F<strong>an</strong> Unit Heaters Only)GPND030 004 006 007 010 012 015 017 020 022 025 030 035 040Ordering No.Contact Macon Product SupportQu<strong>an</strong>tity Requiredfor Ordering InformationNotes:1. Kits are for use in modifying existing units in the field. Kits for GPND-003 thru 007 are complete assemblies including frame <strong>an</strong>d louvers. Kits for all other units includeindividual louver with fastening springs.2. When ordering vertical louvers for new equipment, refer to Table PTAC/UH-11-A.3. These Kits are not available for Tubular Heat Exch<strong>an</strong>ger units.Contact Macon Product Support for moreinformation on these products (1-800-322-6495)Effective 1/1/06PTAC/UH-14The State of California requires a steady-state efficiency of 80% forboth indoor <strong>an</strong>d outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.


Indoor Gas Heating ProductsIndoor Unit Accessories(Field Installed)Table PTAC/UH-15-A— Natural to Prop<strong>an</strong>e Gas Conversion Packages — Single StageUnit Type <strong>an</strong>d Size— Converting — Ordering No.Pilot Type From To 350-0119-St<strong>an</strong>ding GPND-003-A GPPD-003-A 01Pilot 1 GPND-004-A GPPD-004-A 02GPND-006-A GPPD-006-A 04GPND-007-A GPPD-007-A 06GPND-010-A GPPD-010-A 07GPND-012-A GPPD-012-A 08GCND-012-AGCPD-012-AGPND-015-A GPPD-015-A 09GCND-015-AGCPD-015-AGPND-017-A GPPD-017-A 10GCND-017-AGCPD-017-AGPND-020-A GPPD-020-A 11GCND-020-AGCPD-020-AGPND-022-A GPPD-022-A 12GCND-022-AGCPD-022-AGPND-025-A GPPD-025-A 13GCND-025-AGCPD-025-AGPND-030-A GPPD-030-A 14GCND-030-AGCPD-030-AGPND-035-A GPPD-035-A 15GCND-035-AGCPD-035-AGPND-040-A GPPD-040-A 16GCND-040-AGCPD-040-AGDND-010-A GDPD-010-A 35GDND-012-A GDPD-012-A 36GDND-015-A GDPD-015-A 37GDND-017-A GDPD-017-A 38GDND-020-A GDPD-020-A 39GDND-022-A GDPD-022-A 40GDND-025-A GDPD-025-A 41GDND-030-A GDPD-030-A 42GDND-035-A GDPD-035-A 43GDND-040-A GDPD-040-A 44Intermittent Pilot 2 Not Available — Not AvailableNotes:1. Conversion packages are for use in modifying existing units in the field from Natural Gas to Prop<strong>an</strong>e Gas. Use only with units with Single Stage — St<strong>an</strong>ding Pilot gascontrols. D Development Series Only.2. Conversion Packages to convert from Natural Gas to Prop<strong>an</strong>e Gas with intermittent pilot ignition are not available.3. When ordering conversion packages, complete Model Number <strong>an</strong>d Serial Number must be included in the body of the order.4. Control product marketing for units with development sequence prior to “D”.5. Kit includes pilot burner, main burner orifices <strong>an</strong>d a spring for the existing valve.6. For these kits you may receive <strong>an</strong>y of the numbers selected due to the fact all kits are the same:350-0119-01, 02, 04 <strong>an</strong>d 06 – all the same.350-0119-07, 08, 09 <strong>an</strong>d 10 – all the same.350-0119-14, 15 <strong>an</strong>d 16 – all the same.The State of California requires a steady-state efficiency of 80% forboth indoor <strong>an</strong>d outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.Contact Macon Product Support for moreinformation on these products (1-800-322-6495)PTAC/UH-15 Effective 1/1/06


Indoor Gas Heating ProductsIndoor Unit Accessories(Field Installed)Table PTAC/UH-16-A—Prop<strong>an</strong>e to Natural Gas Conversion Packages— Single StageUnit Type <strong>an</strong>d Size— Converting — Ordering No.Pilot Type From To 350-0119-St<strong>an</strong>ding GPP*-003-A GPN*-003-A 17Pilot 1 GPP*-004-A GPN*-004-A 18GPP*-006-A GPN*-006-A 20GPP*-007-A GPN*-007-A 22GPP*-010-A GPN*-010-A 23GCP*-010-AGCN*-010-AGPP*-012-A GPN*-012-A 24GCP*-012-AGCN*-012-AGPP*-015-A GPN*-015-A 25GCP*-015-AGCN*-015-AGPP*-017-A GPN*-017-A 26GCP*-017-AGCN*-017-AGPP*-020-A GPN*-020-A 27GCP*-020-AGCN*-020-AGPP*-022-A GPN*-022-A 28GCP*-022-AGCN*-022-AGPP*-025-A GPN*-025-A 29GCP*-025-AGCN*-025-AGPP*-030-A GPN*-030-A 30GCP*-030-AGCN*-030-AGPP*-035-A GPN*-035-A 31GCP*-035-AGCN*-035-AGPP*-040-A GPN*-040-A 32GCP*-040-AGCN*-040-AGDP*-010-A GDN*-010-A 47GDP*-012-A GDN*-012-A 48GDP*-015-A GDN*-015-A 49GDP*-017-A GDN*-017-A 50GDP*-020-A GDN*-020-A 51GDP*-022-A GDN*-022-A 52GDP*-025-A GDN*-025-A 53GDP*-030-A GDN*-030-A 54GDP*-035-A GDN*-035-A 55GDP*-040-A GDN*-040-A 56Intermittent Pilot 2 All Units Contact Macon Product SupportNotes:1. Conversion packages are for use in modifying existing units in the field from Prop<strong>an</strong>e Gas to Natural Gas. Use only with units with Single Stage gas controls. D DevelopmentSeries Only.2. Conversion Packages — Intermittent Pilot Ignition, are available upon request from the parts department.3. *When ordering conversion packages, complete Model Number <strong>an</strong>d Serial Number must be included in the body of the order. Make sure that the * is replaced by thedevelopment sequence number.4. Kit includes pilot burner, main burner orifices <strong>an</strong>d a gas valve.Contact Macon Product Support for moreinformation on these products (1-800-322-6495)Effective 1/1/06PTAC/UH-16The State of California requires a steady-state efficiency of 80% forboth indoor <strong>an</strong>d outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.


Indoor Gas Heating ProductsIndoor Unit AccessoriesTable PTAC/UH-17-A—All Indoor Duct Furnaces (Std., High Effic. <strong>an</strong>d Separated Combustion Units) Heat Exch<strong>an</strong>ger Warr<strong>an</strong>ty NetPrices Option Extended Warr<strong>an</strong>ty 1 5 year 10 yearUnit MBh 2nd-5th year 2nd-10th yearSize input alum 409SS 321SS alum 409SS 321SS010 100012 125015 150017 175020 200022 225025 250030 300035 350040 400Ordering Number 2705-4000-05-00 2705-4000-06-00Product Code 588 588Note:1. The extension applies only to new equipment installed in domestic sales territories <strong>an</strong>d must be ordered prior to start-up.Table PTAC/UH-17-B—Indoor Unit Shipping WeightsUnit Type 030 004 006 007 010 012 015 017 020 022 025 030 035 040Propeller Unit Heater 70 85 100 110 165 188 210 229 240 266 296 341 405 452High EfficiencyPropeller Unit Heater 79 94 109 119 174 197 219 238 249 275 305 350 414 461High EfficiencyCentrifugal Unit Heater — — — — 262 279 314 336 363 408 427 471 561 594Centrifugal Unit Heater — — — — 253 270 315 335 351 396 415 459 550 582Duct Furnace — — — 140 152 162 180 195 216 224 272 348 360High EfficiencyDuct Furnace — — — — 162 164 174 192 207 228 236 284 360 372Separated CombustionPropeller Unit Heater — — — — 200 228 256 284 312 340 368 432 488 545Centrifugal Unit Heater — — — — 298 330 362 394 426 458 490 558 619 678Separated Combustion — — — — 161 180 188 207 227 246 266 305 344 383Indoor Gas Duct FurnaceTubular Heat Exch<strong>an</strong>ger 72 78 102 108 173 185 195 241 251 — 261 367 381 395Propeller Unit HeaterUnit Size 15 20 30 45Horiz Blower Assy (wt less Motor) 135 155 200 295The State of California requires a steady-state efficiency of 80% forboth indoor <strong>an</strong>d outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.Contact Macon Product Support for moreinformation on these products (1-800-322-6495)PTAC/UH-17 Effective 1/1/06


Propeller Type Unit HeatersModel S — Horizontal Units1. Model S Unit Heaters (Tables PTAC/UH-19-A-PTAC/UH-25-E) include stock units,as well as production unit casing withmotor, coil, f<strong>an</strong>, fin, tube, f<strong>an</strong> guard <strong>an</strong>dhorizontal louvers.2. Units with modified coils (odd numberedunits) are generally not suitable for enteringwater temperatures below 180° because oflow final air temperatures. See EngineeringBulletin EB-UH7 (photocopy only availablefrom Inl<strong>an</strong>d printing 608-783-4700 or onEAGLE), 15-24 for capacity data.3. CoilsThe st<strong>an</strong>dard coil is 1-row 0.031'’ wall 1'’O.D. copper tubing with 108 Sigma-Flo ®aluminum fins per foot <strong>an</strong>d are suitable forservice on steam to 75 psi <strong>an</strong>d water at325° at 200 psi. Coil variations are asindicated inPTAC/UH-18-A.Unit heater name plates will use the 11th digitof the 21 digit model number system todesignate the coil tube material as follows —A — STD. COPPERC — RED BRASSF — STEEL4. MotorsSt<strong>an</strong>dard cycle motors are indicated inPTAC/UH-18-B.Table PTAC/UH-18-A—S Unit Heater Coil — Temperature & Pressure LimitationsTube Steam Hot WaterModel S Material O.D. Wall Pres.-PSIG Deg.°F Pres.-PSIG Deg.°F Fin MaterialCopper (Std.) 1'’ .031'’ 75 325 200 325Red Brass 1'’ .049'’ 75 325 260 390 Alum. or CopperSteel 1'’ .049” 75 325 400 450 (Std.)Table PTAC/UH-18-B—St<strong>an</strong>dard Motors for Model S Unit HeatersTop Avail. Current Thermal Windinghp Speed Speed Type Bearing Char. Overload Insulation1/50 1075 Variable* TE-TOP Sleeve 115/60/1 Yes ‘’B’’Shaded Pole1/20 1550 Variable* TE-TOP Sleeve 115/60/1 Yes ‘’B’’Shaded Pole1/8 1550 Variable* TE-TOP Sleeve 115/60/1 Yes ‘’B’’Perm. Split Cap.1/6-1/4-1/2 1100 1 TE-TOP Ball 115/60/1 Yes ‘’B’’Perm. Split Cap.1/6-1/4-1/2 1140 1 3-Phase Ball 208/230/460/60/3 No ‘’B’’3/4 1140 1 3-Phase Ball 208/230/460/60/3 No “B”1/6-1/4-1/2 1140 1 Exp. Proof Ball 115/60/1 Yes “B”Class I, Group D 208/230/460/60/3 Yes “B”3/4 1145 1 Class II, Group F & G Ball 208/230/460/60/3 Yes “B”Divisions I And IINOTES:1. Special motors (575/60/3) may be ordered by using appropriate designators in the 13th <strong>an</strong>d 14th digits of the model number. Contact St. Louis (888-872-6302) for availability.2. Unit sizes 18S thru 100S with 115/60/1 motors c<strong>an</strong> be operated at variable speeds with the addition of solid-state speed control from Table PTAC/UH-25-B.3. TE = Totally enclosed.4. TOP = Thermal overload protection.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)Effective 1/1/06PTAC/UH-18These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.


Propeller Type Unit HeatersModel S — Const<strong>an</strong>t SpeedTable PTAC/UH-19-A—Packed Stock Horizontal Model S Unit Heaters Const<strong>an</strong>t SpeedCapacitiesLouver Fin Steam @2# <strong>an</strong>d Hot Water @200° EWTDiffuser 60° EAT 60° EAT <strong>an</strong>d 20° WTDUnit Unit Order No. UnitModel Order Digit 17 Ship cfm Final ModelNo. No. B hp rpm wt. # @ 70 Mbh Temp. Mbh gpm No.UHSA- 0136-Model S Horizontal Units — St<strong>an</strong>dard Full Coil18S 0101-01 4601-3049-01 1/50 1075 38 280 17.4 117 3.5 .36 18S20S-2 0102-01 4601-3049-01 1/50 1075 40 318 20.0 118 6.4 .66 20S-238S 0103-01 4601-3049-01 1/20 1550 42 544 38.7 126 19.1 1.97 38S42S 0104-01 4601-3049-01 1/20 1550 42 590 41.6 125 20.0 2.06 42S60S 0105-01 4601-3049-02 1/20 1550 57 815 60.5 129 34.6 3.56 60S70S 0106-01 4601-3049-02 1/8 1550 61 1100 68.2 117 40.4 4.17 70S90S 0107-01 4601-3049-03 1/8 1550 73 1214 87.6 127 55.7 5.74 90S100S 0108-01 4601-3049-03 1/8 1550 84 1535 96.0 118 62.5 6.44 100S126S 0109-01 4601-3049-04 1/6 1100 102 1760 125.7 126 84.9 8.74 126S168S 0110-01 4601-3049-05 1/6 1100 145 2380 172.0 127 115.3 11.88 168S186S 0111-01 4601-3049-05 1/4 1100 147 2808 185.2 121 125.4 12.92 186S230S 0112-01 4601-3049-06 1/4 1100 190 3300 229.7 124 161.7 16.67 230S260S 0113-01 4601-3049-06 1/2 1100 195 4100 256.3 118 181.1 18.67 260S320S 0114-01 4601-3049-07 1/2 1100 245 4480 324.0 127 234.3 24.15 320S354S 0115-01 4601-3049-07 1/2 1100 250 5660 355.5 118 264.9 27.30 354SNotes:1. All units on this page are carried in stock (limited qu<strong>an</strong>tities) for immediate shipment.2. All stock units have single phase motors.3. Unit sizes 18S thru 100S with 115/60/1 std. motors c<strong>an</strong> be operated at variable speeds with addition of solid-state speed control from Table PTAC/UH-25-B.These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)PTAC/UH-19 Effective 1/1/06


Propeller Type Unit HeatersModel S Unit <strong>an</strong>d Motor SelectionsTable PTAC/UH-20-A—Model S Unit <strong>an</strong>d Motor SelectionsUnit Motor MotorSize hp rpm Voltage Type 13th Digit / 14th Digit018 1/50 1075 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T019 1/50 1075 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T020 1/50 1075 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T031 1/20 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T038 1/20 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T042 1/20 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T045 1/20 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T053 1/8 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T060 1/20 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/TContact Waco Product Support for moreinformation on these products (1-888-872-6335)Effective 1/1/06PTAC/UH-20These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.


Propeller Type Unit HeatersModel S Unit <strong>an</strong>d Motor SelectionsTable PTAC/UH-21-A—Model S Unit <strong>an</strong>d Motor Selections (Continued)Unit Motor MotorSize HP RPM Voltage Type 13th Digit / 14th Digit069 1/8 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T070 1/8 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T077 1/8 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T090 1/8 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T091 1/6 1100 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T100 1/8 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T126 1/6 1100 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T127 1/6 1100 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T137 1/4 1100 115/60/1 TE 1/ T1/4 1140 208/230/460/60/3 TE (2,3,4)/ T1/4 1140 115/60/1 X-Proof 1/E1/4 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T168 1/6 1100 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/TThese items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)PTAC/UH-21 Effective 1/1/06


Propeller Type Unit HeatersModel S Unit <strong>an</strong>d Motor SelectionsTable PTAC/UH-22-A—Model S Unit <strong>an</strong>d Motor Selections (Continued)UnitMotorSize HP RPM Voltage Type Digit 13 / Digit 14181 1/4 1100 115/60/1 TE 1/ T1/4 1140 208/230/460/60/3 TE (2,3,4)/ T1/4 1140 115/60/1 X-Proof 1/E1/4 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T186 1/4 1100 115/60/1 TE 1/ T1/4 1140 208/230/460/60/3 TE (2,3,4)/ T1/4 1140 115/60/1 X-Proof 1/E1/4 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T207 1/2 1100 115/60/1 TE 1/ T1/2 1140 208/230/460/60/3 TE (2,3,4)/ T1/2 1140 115/60/1 X-Proof 1/E3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E1/2 1140 575/60/3 Totally Enclosed 5/T230 1/4 1100 115/60/1 TE 1/ T1/4 1140 208/230/460/60/3 TE (2,3,4)/ T1/4 1140 115/60/1 X-Proof 1/E1/4 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T243 1/2 1100 115/60/1 TE 1/ T1/2 1140 208/230/460/60/3 TE (2,3,4)/ T1/2 1140 115/60/1 X-Proof 1/E3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E1/2 1140 575/60/3 Totally Enclosed 5/T260 1/2 1100 115/60/1 TE 1/ T1/2 1140 208/230/460/60/3 TE (2,3,4)/ T1/2 1140 115/60/1 X-Proof 1/E3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E1/2 1140 575/60/3 Totally Enclosed 5/T273 1/2 1100 115/60/1 TE 1/ T1/2 1140 208/230/460/60/3 TE (2,3,4)/ T1/2 1140 115/60/1 X-Proof 1/E3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E1/2 1140 575/60/3 Totally Enclosed 5/T320 1/2 1100 115/60/1 TE 1/ T1/2 1140 208/230/460/60/3 TE (2,3,4)/ T1/2 1140 115/60/1 X-Proof 1/E3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E1/2 1140 575/60/3 Totally Enclosed 5/T354 1/2 1100 115/60/1 TE 1/ T1/2 1140 208/230/460/60/3 TE (2,3,4)/ T1/2 1140 115/60/1 X-Proof 1/E3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E1/2 1140 575/60/3 Totally Enclosed 5/T400 3/4 1140 208/230/460/60/3 TE (2,3,4)/ T3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E3/4 1140 575/60/3 Totally Enclosed 5/TUnits in bold print c<strong>an</strong> also be ordered from packed stock. See Table PTAC/UH-19-A for stock ordering number.Notes:1. Units with modified coils (odd numbered units; 019, 031, etc.) are used in applications with lower final temperatures. These units not available as packed stock.2. All single-phase motors have built-in overload protection.3. 115/60/1, TE motors on unit sizes 18S-90S <strong>an</strong>d 100S c<strong>an</strong> be operated at variable speeds with the addition of a solid-state speed control. See Table PTAC/UH-25-B for selection.4. All explosion-proof motors meet Class I, Group D; Class II, Group F <strong>an</strong>d G; Divisions 1 <strong>an</strong>d 2.5. Verify electrical characteristics of motors are ordered correctly.6. Special motor requirements are available. Contact St. Louis (888-872-6302) for availability.7. TE = Totally Enclosed8. X-Proof = Explosion ProofContact Waco Product Support for moreinformation on these products (1-888-872-6335)Effective 1/1/06PTAC/UH-22These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.


Propeller Type Unit HeatersModel S Coil <strong>an</strong>d FinTTable PTAC/UH-23-A—Model S Coil TypeUnit SizeDesignator018 SW019* SW020 SW031* SW038 SW042 SW045* SW053* SW060 SW069* SW070 SW077* SW090 SW091* SW100 SW126 SW127* SW137* SW168 SW181* SW186 SW207* SW230 SW243* SW260 SW273* SW320 SW354 SW400 SW*Units have modified coil for lower outlet temperatures.Notes:1. Std = St<strong>an</strong>dard2. Type “S” coils c<strong>an</strong> be operated with either steam or hot water.3. Type “W” coils are for use with hot water only <strong>an</strong>d have turbulators.These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.Table PTAC/UH-23-B—Model S Fin SeriesUnit SizeDesignator018 82019 82020 82031 82038 82042 82045 82053 82060 82069 82070 82077 82090 82091 82100 82126 82127 82137 82168 82181 82186 82207 82230 82243 82260 82273 82320 82354 82400 82Notes:1. Std = St<strong>an</strong>dard2. N/C = No Charge3. Selection of digit “8” equals 108 fins per foot.4. Selection of digit “2” equals 132 fins per foot.5. 132 fins per foot is st<strong>an</strong>dard on models 020, 019 <strong>an</strong>d 400.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)PTAC/UH-23 Effective 1/1/06


Propeller Type Unit HeatersModel S Tube MaterialTable PTAC/UH-24-A—Model S Tube MaterialUnit Size Type Designator018 Copper ARed BrassCSteelF019 Copper ARed BrassCSteelF020 Copper ARed BrassCSteelF031 Copper ARed BrassCSteelF038 Copper ARed BrassCSteelF042 Copper ARed BrassCSteelF045 Copper ARed BrassCSteelF053 Copper ARed BrassCSteelF060 Copper ARed BrassCSteelF069 Copper ARed BrassCSteelF070 Copper ARed BrassCSteelF077 Copper ARed BrassCSteelF090 Copper ARed BrassCSteelF091 Copper ARed BrassCSteelF100 Copper ARed BrassCSteelFTable PTAC/UH-24-B—(Continued) Model S Tube MaterialUnit Size Type Designator126 Copper ARed BrassCSteelF127 Copper ARed BrassCSteelF137 Copper ARed BrassCSteelF168 Copper ARed BrassCSteelF181 Copper ARed BrassCSteelF186 Copper ARed BrassCSteelF207 Copper ARed BrassCSteelF230 Copper ARed BrassCSteelF243 Copper ARed BrassCSteelF260 Copper ARed BrassCSteelF273 Copper ARed BrassCSteelF320 Copper ARed BrassCSteelF354 Copper ARed BrassCSteelF400 Copper ARed BrassCSteelFNote:1. Std = St<strong>an</strong>dard2. Tube temperature <strong>an</strong>d pressure limitations found in Table PTAC/UH-18-A.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)Effective 1/1/06PTAC/UH-24These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.


Propeller Type Unit HeatersModel S Accessories <strong>an</strong>d CoatingsS OSHA Wire GuardsTable PTAC/UH-25-A—Model S Louver Fin Diffuser136-0162-01 KBWC-15 Solid-State Speed Control 6Unit Size Ordering Number Digit 17Table PTAC/UH-25-D—Model(St<strong>an</strong>dard Units Only)018 4601-3049-01 BUnit Size Ordering Number019 4601-3049-01 B018 0136-0251-01020 4601-3049-01 B019 0136-0251-02031 4601-3049-01 B020 0136-0251-03038 4601-3049-01 B031 0136-0251-04042 4601-3049-01 B038 0136-0251-05045 4601-3049-02 B042 0136-0251-06053 4601-3049-02 B045 0136-0252-01060 4601-3049-02 B053 0136-0252-03069 4601-3049-03 B060 0136-0252-02070 4601-3049-02 B069 0136-0252-05077 4601-3049-03 B070 0136-0252-04090 4601-3049-03 B077 0136-0253-01091 4601-3049-04 B090 0136-0252-06100 4601-3049-03 B091 0136-0253-02126 4601-3049-04 B100 0136-0253-03127 4601-3049-05 B126 0136-0253-04137 4601-3049-05 B127 0136-0254-03168 4601-3049-05 B137 0136-0254-04181 4601-3049-06 B168 0136-0254-01186 4601-3049-05 B181 0136-0254-05207 4601-3049-06 B186 0136-0254-02230 4601-3049-06 B207 0136-0255-01243 4601-3049-07 B230 0136-0254-06260 4601-3049-06 B243 0136-0255-02273 4601-3049-07 B260 0136-0255-03320 4601-3049-07 B273 0136-0255-04354 4601-3049-07 B320 0136-0255-05400 4601-3049-07 B354 0136-0255-06Table PTAC/UH-25-B—Model S & P Starter <strong>an</strong>d ControlAccessoriesOrdering ModelNumber Number Description3. To order OSHA guards for st<strong>an</strong>dard unit, digit 15 must be A.X13011500 600 TAX 4 M<strong>an</strong>ual Starter without 1overload protectionX13510361-01 T451A Light-Duty Thermostat 2EpoxyX13530027-01 Q473B Light-Duty Subbase 3X13080500 T6051A Heavy-Duty Thermostat 4X13530028-01 Q651A Heavy-Duty Subbase 5Table PTAC/UH-25-C— Model S & P Starter <strong>an</strong>dControl Accessories (Continued)DigitDesignator18 A20 B21 E20 C21 F19 DNotes:1. NEMA Type 1, single-pole, single-throw, one hp, 110 220V, toggle operated. Foruse on single-phase operation only.2. Line voltage 8.0 Amps, 56°-94° r<strong>an</strong>ge.3. Auto-off. For use with light duty thermostat.4. Line voltage 16.0 Amps, 45°-85° r<strong>an</strong>ge.5. Auto-off-on for use with heavy-duty thermostat.6. 120V, five Amps. (Only available up to 100S).Notes:1. OSHA guards will be factory installed when ordered with a corresponding st<strong>an</strong>dard unitheater.2. Field installation of “type 2” motor mounts (three-phase <strong>an</strong>d explosion-proof motors)requires cutting portions of the guard to fit over motor side arm. Guards are not OSHA.Table PTAC/UH-25-E—Special Coatings for Model S Unit HeatersBakedUnit Size Epoxy Phenolic Phenolic18,19,20,31,38,42,45,5360,69,70,77,90,91100,126,127,137168,181,186,207,230243,260,273,320354,400Digit 17/D: Any Coating on All Louver Fin Diffusers =Notes:1. Surface preparation: s<strong>an</strong>dblasting, except coils which are chemically cle<strong>an</strong>ed. Inside <strong>an</strong>doutside of each casing, f<strong>an</strong> blade <strong>an</strong>d heating coil are special coated. Motors c<strong>an</strong>not bespecial coated.2. Epoxy Coating (Digit 16/R) : Two coats on all subassemblies <strong>an</strong>d one coat on assembled.Unit force cured at 150° F.3. Epoxy Phenolic Coating (Digit 16/T): Two coats on all subassemblies <strong>an</strong>d one coat onassembled. Unit force cured at 150°F.4. Baked Phenolic Coating (Digit 16/W): Four coats on all surfaces. Baked at 325°F onintermediate coats <strong>an</strong>d 425°F on cure.5. To order, enter appropriate designator in digit 16.6. All units reshipped in original cartons.These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)PTAC/UH-25 Effective 1/1/06


Propeller Type Unit HeatersModel P — Vertical Units1. Model P Unit Heaters (Tables PTAC/UH-27-A-PTAC/UH-30-A) include stock units,as well as production unit casing withmotor, coil, fin, tube, f<strong>an</strong> guard <strong>an</strong>d f<strong>an</strong>.2. Model PL Unit Heaters are identical toModel P. The perform<strong>an</strong>ce difference is aresult of removing the air ports in the field.3. CoilsThe st<strong>an</strong>dard coil 1-row 0.025'’ wall 5/8'’O.D. copper with 144 Sigma-Flo ® aluminumfins per foot <strong>an</strong>d threaded steel pipeheaders. Coils are suitable for service on75 psi steam or water at 325 F at 225 psi.Coil variations are as indicated in TablePTAC/UH-26-A.4. Unit heater name plates will use the 11thdigit of the 21 digit model number systemto designate the coil tube material asfollows:A — STD. COPPERC — RED BRASSF — STEEL5. MotorsSt<strong>an</strong>dard cycle motors are described inTable PTAC/UH-26-B.Special motors may be ordered.(575/60/3) by putting appropriatedesignators in Digits 13 <strong>an</strong>d 14 of modelnumber. Contact St. Louis (888-872-6302)Table PTAC/UH-26-A—Type ‘’P’’ Unit Heater Coil — Temperature & Pressure LimitationsTube Steam Hot WaterModel P Material O.D. Wall Pres.-PSIG Deg.°F Pres.-PSIG Deg.°F Fin MaterialCopper (Std.) 5/8'’ .025'’ 75 325 225 325Red Brass 5/8'’ .049'’ 75 325 300 425 Alum. or CopperSteel 5/8'’ .049'’ 75 325 400 450 (Std.)Table PTAC/UH-26-B—St<strong>an</strong>dard Motors for Model P Unit HeatersTop Avail. Current Thermal Windinghp Speed Speed Type Bearing Char. Overload Insulation1/40-1/20 1550 Variable TE-TOP Sleeve 115/60/1 Yes ‘’B’’Shaded Pole1/8 1070 Variable TE-TOP PSC Sleeve 115/60/1 Yes ‘’B’’1/6-1/4-1/2 1100 1 TE-TOP Ball 115/60/1 Yes ‘’B’’Perm. Split Cap.1/6-1/4-1/2 1140 1 3-Phase Ball 208/230/460/60/3 No ‘’B’’3/4 1140 1 TE Polyphase Ball 208/230/460/60/3 No ‘’B’’1½ 1160 1 TE Polyphase Ball 208/230/460/60/3 No “B”3 1165 1 TE Polyphase Ball 208/230/460/60/3 No “B”1/6-1/4-1/2 1140 1 Exp. Proof Ball 115/60/1 Yes “B”3 1150 1 Class I, Group D Ball 208/230/460/60/3 Yes “B”3/4 1145 1 Class II, Group F & G Ball 230/460/60/3 Yes “B”Divisions I <strong>an</strong>d II1½ 1150 1 Ball 230/460/60/3 Yes “B”1. Special motors (575/60/3) may be ordered by using appropriate designators in digits 13 <strong>an</strong>d 14 of model number. Contact St. Louis(888-872-6302) for availability.2. Unit sizes 42P thru 102P may be operated as variable speeds with addition of solid-state control from Table PTAC/UH-29-C.3. TE = Totally Enclosed4. TOP = Thermal Overload Protection5. PSC = Perm<strong>an</strong>ent Split Capacitor.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)Effective 1/1/06PTAC/UH-26These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.


Propeller Type Unit HeatersModel P — Const<strong>an</strong>t Speed <strong>an</strong>dMotor SelectionsTable PTAC/UH-27-A—Packed Stock Vertical Model P Unit Heaters Const<strong>an</strong>t SpeedCapacitiesSteam @2# <strong>an</strong>d Hot Water @200° EWTLouver (Digit 17/A) 60° EAT 60° EAT <strong>an</strong>d 20° WTDUnit Unit Cone UnitModel Order Diffuser Ship cfm Final ModelNo. No. Order No. hp rpm wt. # @ 70 Mbh Temp. Mbh gpm No.UHPA- 136- Model P (St<strong>an</strong>dard Vertical Units)42P* 0143-01 4607-330-01 1/40 1550 28 595 41.3 124 22.7 2.34 42P64P* 0144-01 4607-330-02 1/20 1550 37 989 65.5 121 39.6 4.08 64P80P* 0145-01 4607-330-02 1/20 1550 41 1200 80.6 122 48.4 4.99 80P102P* 0146-01 4607-330-03 1/8 1070 57 1490 101.8 123 68.3 7.03 102P122P 0147-01 4607-330-03 1/6 1100 57 1790 124.4 124 83.7 8.63 122P146P 0148-01 4607-330-04 1/6 1100 80 2220 152.0 123 105.2 10.84 146P166P 0149-01 4607-330-04 1/6 1100 82 2620 173.0 121 118.6 12.22 166P202P 0150-01 4607-330-04 1/4 1100 86 3200 201.2 118 139.7 14.40 202P252P 0151-01 4607-330-05 1/4 1100 134 4180 249.8 115 180.1 18.56 252P280P 0152-01 4607-330-05 1/2 1100 134 4430 283.8 119 205.4 21.17 280P336P 0153-01 4607-330-05 3/4 1140 144 5210 333.4 119 242.9 25.03 336PUHPA- 136- P-L (St<strong>an</strong>dard Model P with all Air-Ports Opened)42P* 0143-01 4607-330-01 1/40 1550 28 668 34.8 108 18.9 1.95 42P64P* 0144-01 4607-330-02 1/20 1550 37 1200 57.2 104 34.2 3.53 64P80P* 0145-01 4607-330-02 1/20 1550 41 1360 68.0 106 40.5 4.17 80P102P* 0146-01 4607-330-03 1/8 1070 57 1640 85.4 108 56.5 5.82 102P122P 0147-01 4607-330-03 1/6 1100 57 2180 111.0 107 73.9 7.62 122P146P 0148-01 4607-330-04 1/6 1100 80 2360 125.8 109 85.5 8.81 146P166P 0149-01 4607-330-04 1/6 1100 82 2920 149.0 107 100.7 10.38 166P202P 0150-01 4607-330-04 1/4 1100 86 3390 176.8 108 121.5 12.52 202P252P 0151-01 4607-330-05 1/4 1100 134 4500 214.9 104 153.8 15.85 252P280P 0152-01 4607-330-05 1/2 1100 134 5040 251.8 106 180.1 18.56 280P336P 0153-01 4607-330-05 3/4 1140 144 5700 291.0 107 210.6 21.70 336P*These units may be operated as variable speed with the addition of the solid-state control from Table PTAC/UH-29-C.Notes:1. All stock units have single phase motors except the 336P which has three-phase.2. All units on this page are available from stock for immediate shipment. Contact St. Louis (888-872-6302) for availability.3. Be sure the electrical characteristics of motors ordered are correct.Table PTAC/UH-27-B—Model P Unit <strong>an</strong>d Motor SelectionsUnit Motor MotorSize hp rpm Voltage Type 13th Digit / 14th Digit042 1/40 1550 115/60/1 TE 1/T1/6 1140 208/230/460/60/3 TE (2,3,4)/T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T064 1/20 1550 115/60/1 TE 1/T1/6 1140 208/230/460/60/3 TE (2,3,4)/T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T080 1/20 1550 115/60/1 TE 1/T1/6 1140 208/230/460/60/3 TE (2,3,4)/T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T102 1/8 1070 115/60/1 TE 1/T1/6 1140 208/230/460/60/3 TE (2,3,4)/T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T122 1/6 1100 115/60/1 TE 1/T1/6 1140 208/230/460/60/3 TE (2,3,4)/T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/TThese items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)PTAC/UH-27 Effective 1/1/06


Propeller Type Unit HeatersModel P — Motor SelectionsTable PTAC/UH-28-A— Model P Unit <strong>an</strong>d Motor Selections (Continued)Unit Motor MotorSize hp rpm Voltage Type 13th Digit / 14th Digit146 1/6 1100 115/60/1 TE 1/T1/6 1140 208/230/460/60/3 TE (2,3,4)/T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T166 1/6 1100 115/60/1 TE 1/T1/6 1140 208/230/460/60/3 TE (2,3,4)/T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T202 1/4 1100 115/60/1 TE 1/T1/4 1140 208/230/460/60/3 TE (2,3,4)/T1/4 1140 115/60/1 X-Proof 1/E1/4 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T252 1/4 1100 115/60/1 TE 1/T1/4 1140 208/230/460/60/3 TE (2,3,4)/T1/4 1140 115/60/1 X-Proof 1/E1/4 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T280 1/2 1100 115/60/1 TE 1/T1/2 1140 208/230/460/60/3 TE (2,3,4)/T1/2 1140 115/60/1 X-Proof 1/E1/2 1140 230/460/60/3 X-Proof (3,4)/E1/2 1140 575/60/3 Totally Enclosed 5/T336 3/4 1140 208/230/460/60/3 TE (2,3,4)/T3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E3/4 1140 575/60/3 Totally Enclosed 5/T384 3/4 1140 208/230/460/60/3 TE (2,3,4)/T3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E3/4 1140 575/60/3 Totally Enclosed 5/T500 1-½ 1160 208/230/460/60/3 TE (2,3,4)/T1-½ 1150 230/460/60/3 X-Proof (3,4)/E1-½ 1160 575/60/3 Totally Enclosed 5/T600 1-½ 1160 208/230/460/60/3 TE (2,3,4)/T1-½ 1150 230/460/60/3 X-Proof (3,4)/E1-½ 1160 575/60/3 Totally Enclosed 5/T720 3 1165 208/230/460/60/3 TE (2,3,4)/T3 1150 230/460/60/3 X-Proof (3,4)/E3 1165 575/60/3 Totally Enclosed 5/TUnits in bold print c<strong>an</strong> be ordered from packed stock. See Table PTAC/UH-27-A for ordering information.Notes:1. All single-phase motors have built-in overload protection.2. All explosion-proof motors meet Class I, Group D; Class II, Group F <strong>an</strong>d G; Divisions 1 <strong>an</strong>d 2.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)Effective 1/1/06PTAC/UH-28These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.


Propeller Type Unit HeatersModel P — AccessoriesTable PTAC/UH-29-A—Model P Tube MaterialUnit Size Type Designator042 Copper ARed BrassCSteelF064 Copper ARed BrassCSteelF080 Copper ARed BrassCSteelF102 Copper ARed BrassCSteelF122 Copper ARed BrassCSteelF146 Copper ARed BrassCSteelF166 Copper ARed BrassCSteelF202 Copper ARed BrassCSteelF252 Copper ARed BrassCSteelF280 Copper ARed BrassCSteelF336 Copper ARed BrassCSteelF384 Copper ARed BrassCSteelF500 Copper ARed BrassCSteelF600 Copper ARed BrassCSteelF720 Copper ARed BrassCSteelFNotes:1. Std = St<strong>an</strong>dard2. Tube temperature <strong>an</strong>d pressure limitations found in Table PTAC/UH-26-A.These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.Table PTAC/UH-29-B—Model P Louver Cone DiffuserUnit Size Designator Digit 17042 4607-0330-01 A064 4607-0330-02 A080 4607-0330-02 A102 4607-0330-03 A122 4607-0330-03 A146 4607-0330-04 A166 4607-0330-04 A202 4607-0330-04 A252 4607-0330-05 A280 4607-0330-05 A336 4607-0330-05 A384 4607-0330-05 A500 4607-0330-06 A600 4607-0330-06 A720 4607-0330-06 ATable PTAC/UH-29-C—Model S & P Starter <strong>an</strong>d ControlAccessoriesOrdering ModelNumber Number DescriptionX13011500 600 TAX 4 M<strong>an</strong>ual Starter without 1overload protectionX13510361-01 T451A A Light-Duty Thermostat 2X13530027-01 Q473B Light-Duty Subbase 3X13080500 T6051A Heavy-Duty Thermostat 4X13530028-01 Q651A Heavy-Duty Subbase 5136-0162-01 KBWC-15 Solid-State Speed Control 6Table PTAC/UH-29-D— Model S & P Starter <strong>an</strong>dControl Accessories (Continued)DigitDesignator18 A20 B21 E20 C21 F19 DNotes:1. NEMA Type 1, single-pole, single-throw, one hp, 110-220V toggle operated. Foruse on single-phase operation only.2. Line voltage 8.0 Amps, 56°-94° r<strong>an</strong>ge.3. Auto-off. For use with light duty thermostat.4. Line voltage 16.0 Amps, 45°-85° r<strong>an</strong>ge.5. Auto-off-on for use with heavy-duty thermostat.6. 120V, Five Amps.Table PTAC/UH-29-E—Model P OSHA Wire GuardsUnit Size Designator Digit 15042 0136-0256-01 A064 0136-0257-01 A080 0136-0257-02 A102 0136-0258-01 A122 0136-0258-02 A146 0136-0259-01 A166 0136-0259-02 A202 0136-0259-03 A252 0136-0260-01 A280 0136-0260-02 A336 0136-0260-03 A384 0136-0260-04 A500 0136-0261-01 A600 0136-0261-02 A720 0136-0261-03 ANotes:1. OSHA guards will be factory installed when ordered with a corresponding unitheater.2. For the 3-phase <strong>an</strong>d explosion-proof motor, the OSHA guard ships separately.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)PTAC/UH-29 Effective 1/1/06


Propeller Type Unit HeatersModel P CoatingsModel S <strong>an</strong>d P Order Numbers <strong>an</strong>dEquivalent Production NumbersTable PTAC/UH-30-A— Special Coatings for Model P Unit HeatersEpoxy BakedUnit Size Epoxy Phenolic Phenolic042, 064, 080102, 122146, 166, 202252, 280, 336, 384500, 600720Digit 17/C - Any Coating on All Louver Cone Diffusers = $248 list priceNotes:1. Surface preparation: s<strong>an</strong>dblasting, except coils which are chemically cle<strong>an</strong>ed. Inside <strong>an</strong>d outside of each casing, f<strong>an</strong> blade <strong>an</strong>d heating coil are special coated. Motors c<strong>an</strong>notbe special coated.2. Epoxy Coating Coating (Digit 16/R): Two coats on all subassemblies <strong>an</strong>d one coat on assembled. Unit force cured at 150°F.3. Epoxy Phenolic Coating (Digit 16/T): Two coats on all subassemblies <strong>an</strong>d one coat on assembled. Unit force cured at 150°F.4. Baked Phenolic Coating (Digit 16/W): Four coats on all surfaces. Baked at 325°F on intermediate coats <strong>an</strong>d 425°F on cure. Units are reshipped in original cartons.5. To order, enter appropriate in digit 16 of model number.Table PTAC/UH-30-B— Packed Stock Model S Unit Heater Order Numbers & Equivalent Production Model NumbersHorizontal Model S Unit Heaters Const<strong>an</strong>t SpeedStock Order Production OrderSize Order No. Type Model No. Type Notes18S 136-0101-01 STK UHSA018S8EAA1T0000000 PRD 120S2* 136-0102-01 STK UHSA020S2EAA1T0000000 PRD 138S 136-0103-01 STK UHSA038S8EAA1T0000000 PRD 142S 136-0104-01 STK UHSA042S8EAA1T0000000 PRD 160S 136-0105-01 STK UHSA060S8EAA1T0000000 PRD 170S 136-0106-01 STK UHSA070S8EAA1T0000000 PRD 190S 136-0107-01 STK UHSA090S8EAA1T0000000 PRD 1100S 136-0108-01 STK UHSA100S8EAA1T0000000 PRD 1126S 136-0109-01 STK UHSA126S8EAA1T0000000 PRD 1168S 136-0110-01 STK UHSA168S8EAA1T0000000 PRD 1186S 136-0111-01 STK UHSA186S8EAA1T0000000 PRD 1230S 136-0112-01 STK UHSA230S8EAA1T0000000 PRD 1260S 136-0113-01 STK UHSA260S8EAA1T0000000 PRD 1320S 136-0114-01 STK UHSA320S8EAA1T0000000 PRD 1354S 136-0115-01 STK UHSA354S8EAA1T0000000 PRD 1Notes:1. For steam or hot water coils made from .031 copper tubes. Aluminum fins (*108 per foot) <strong>an</strong>d steel pipe headers. F<strong>an</strong>s made with steel hubs <strong>an</strong>d aluminum blades. Sleevebearing motors are 115/60/1. TEAOM with TOP <strong>an</strong>d class B insulation. Type No. 1 motor mount (wire guard) furnished. Variable speed motors furnished on sizes 18S thru 100Sas st<strong>an</strong>dard. Requires a solid-state speed control which must be ordered separately. Unit casings top, front, back <strong>an</strong>d sides made from steel with adjustable louversphosphatized <strong>an</strong>d painted with a blue-gray baked enamel finish.*Size 20S2 stock unit furnished with 132 fins per foot as st<strong>an</strong>dard.Table PTAC/UH-30-C— Packed Stock Model P Unit Heater Order Numbers & Equivalent Production Model NumbersVertical Model P Unit Heaters Const<strong>an</strong>t SpeedStock Order Production OrderSize Order No. Type Model No. Type Notes42P 136-0143-01 STK UHPA042P4CAA1T0000000 PRD 164P 136-0144-01 STK UHPA064P4CAA1T0000000 PRD 180P 136-0145-01 STK UHPA080P4CAA1T0000000 PRD 1102P 136-0146-01 STK UHPA102P4CAA1T0000000 PRD 1122P 136-0147-01 STK UHPA122P4CAA1T0000000 PRD 1146P 136-0148-01 STK UHPA146P4CAA1T0000000 PRD 1166S 136-0149-01 STK UHPA166P4CAA1T0000000 PRD 1202P 136-0150-01 STK UHPA202P4CAA1T0000000 PRD 1252P 136-0151-01 STK UHPA252P4CAA1T0000000 PRD 1280P 136-0152-01 STK UHPA280P4CAA1T0000000 PRD 1336P* 136-0153-01 STK UHPA336P4CAA1T0000000 PRD 1Notes:1. For steam or hot water coils made from .025 copper tubes. Aluminum fins (144 per foot) <strong>an</strong>d steel pipe headers. F<strong>an</strong>s made with steel hubs <strong>an</strong>d aluminum blades. Sleevebearing motors are provided for 1/20 & 1/8 HP r<strong>an</strong>ges <strong>an</strong>d ball bearing motors provided for 1/6, 1/4, & 1/2 HP r<strong>an</strong>ges are 115/60/1. TE with TOP <strong>an</strong>d class B insulation. Steelmotor mount furnished. Variable speed motors furnished on sizes 42P thru 102P as st<strong>an</strong>dard. Requires a solid-state speed control which must be ordered separately. Casingsmade from two steel plates with the top plate having air ports as st<strong>an</strong>dard, phosphatized <strong>an</strong>d painted with a blue-gray baked enamel finish.*Size 336P stock unit uses a 230/460/60/3, ball bearing, TE with class B insulation motor as st<strong>an</strong>dard.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)Effective 1/1/06PTAC/UH-30These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.


Electric Unit HeatersVoltage ControlTable PTAC/UH-31-A— St<strong>an</strong>dard with 24V Control Tr<strong>an</strong>sformer <strong>an</strong>d ContactorOrder Element Std.kW No. Element & Motor Amp Control ShipRating UHEC 236- Phase Voltage Rating Voltage wt lbs031AACA -246 1 208 15.9 24 253.3 kW 031CACA -248 1 277 11.9 24 25033DACA -182 3 480 4.0 24 25052AACA -250 1-3 208 24.1 24 255.0 kW 052BACA -252 1-3 240/208 20.9/18.1 24 25053DACA -194 3 480 6.1 24 25072AACA -196 1-3 208 36.1 24 50072BACA -198 1-3 240/208 31.3/27.1 24 507.5 kW 071CACA -200 1 277 27.1 24 50073DACA -202 3 480 9.1 24 50102AACA -204 1-3 208 47.8 24 50102BACA -206 1-3 240/208 42.2/36.1 24 5010 kW 101CACA -208 1 277 36.1 24 50103DACA -210 3 480 12.1 24 50153AACA -212 3 208 41.7 24 6515 kW 153BACA -214 3 240/208 36.1/31.3 24 65153DACA -216 3 480 18.1 24 65203BACA -218 3 240/208 47.8/41.1 24 6520 kW 203DACA -220 3 480 24.1 24 65253AACA -222 3 208 69.5 24 12025 kW 253BACA -224 3 240/208 60.2/52.1 24 120253DACA -226 3 480 30.1 24 120303AACA -228 3 208 83.4 24 12030 kW 303DACA -232 3 480 36.2 24 120403BACA -236 3 240/208 96.4/83.4 24 12040 kW 403DACA -238 3 480 47.0 24 12050 kW 503DACA -244 3 480 60.3 24 1201. Supply wire must have 75°C minimum insulation.2. Each Electric Unit Heater in Table PTAC/UH-31-A is provided with a factory installed Tr<strong>an</strong>sformer <strong>an</strong>d Contactor as st<strong>an</strong>dard for 24V control voltage.3. All 25-50 kW units are factory wired for two-stage operation as st<strong>an</strong>dard. To operate on two-stage, a two-stage thermostat must be ordered.4. All 25-50 kW units are equipped with two-speed motors <strong>an</strong>d factory installed Speed Switches as st<strong>an</strong>dard.Table PTAC/UH-31-B— St<strong>an</strong>dard Units for Line Voltage ControlOrder Element Std.kW No. Element & Motor Amp Control ShipRating UHEC 236- Phase Voltage Rating Voltage wt. lbs031A0C0 -172 1 208 15.9 208 25031B0C0 -174 1 240/208 13.7/11.9 240/208 253.3 kW 032A0C0 -176 1-3 208 15.9 208 25032B0C0 -178 1-3 240/208 13.7/11.9 240/208 25031C0C0 -180 1 277 11.9 277 25051A0C0 -184 1 208 24.1 208 25051B0C0 -186 1 240/208 20.9/18.1 240/208 255.0 kW 052A0C0 -188 1-3 208 24.1 208 25052B0C0 -190 1-3 240/208 20.9/18.1 240/208 25051C0C0 -192 1 277 18.1 277 251. Supply wire must have 75°C minimum insulation.2. Tr<strong>an</strong>sformers <strong>an</strong>d Contactors are not furnished for these units.3. The control voltage is line voltage.These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)PTAC/UH-31 Effective 1/1/06


Electric Unit HeatersVoltage ControlTable PTAC/UH-32-A—Production with 24V Control Voltage Tr<strong>an</strong>sformer & ContactorOrder Element Std.kW No. Element & Motor Amp Control ShipRating UHEC 236- Phase Voltage Rating Voltage wt. lbs031BACA SPEC 1 240/208 13.7/11.9 24 253.3 kW 032AACA SPEC 1-3 208 15.9 24 25032BACA SPEC 1-3 240/208 13.7/11.9 24 25051AACA SPEC 1 208 24.1 24 255.0 kW 051BACA SPEC 1 240/208 20.9/18.1 24 25051CACA SPEC 1 277 18.1 24 2530 kW 303BACA SPEC 3 240/208 72.3/62.5 24 12040 kW 403AACA SPEC 3 208 111.2 24 120503AACA SPEC 3 208 139.0 24 12050 kW 503BACA SPEC 3 240/208 120.5/104.3 24 1201. Supply wire must have 75°C minimum insulation.2. Each Electric Unit Heater in Table PTAC/UH-32-A is provided with a factory installed Tr<strong>an</strong>sformer <strong>an</strong>d Contactor as st<strong>an</strong>dard for 24V control voltage.3. All 30-50 kW units are factory wired for two-stage operation as st<strong>an</strong>dard. To operate on two-stage, a two-stage thermostat must be ordered.4. All 30-50 kW units are equipped with two-speed motors <strong>an</strong>d factory installed Speed Switches as st<strong>an</strong>dard.5. Use the model number to order.Table PTAC/UH-32-B—Production Units for Line Voltage Control with ContactorOrder Element Std.kW No. Element & Motor Amp Control ShipRating UHEC 236- Phase Voltage Rating Voltage wt. lbs031A0CA SPEC 1 208 15.9 208 25031B0CA SPEC 1 240/208 13.7/11.9 240/208 253.3 kW 032A0CA SPEC 1-3 208 15.9 208 25032B0CA SPEC 1-3 240/208 13.7/11.9 240/208 25031C0CA SPEC 1 277 11.9 277 25051A0CA SPEC 1 208 24.1 208 25051B0CA SPEC 1 240/208 20.9/18.1 240/208 255.0 kW 052A0CA SPEC 1-3 208 24.1 208 25052B0CA SPEC 1-3 240/208 20.9/18.1 240/208 25051C0CA SPEC 1 277 18.1 277 251. Supply wire must have 75°C insulation minimum.2. Tr<strong>an</strong>sformer not provided for these units.3. Contactor provided as st<strong>an</strong>dard for these units.4. Use the model number to order.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)Effective 1/1/06PTAC/UH-32These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.


Electric Unit HeatersControl Options(Field Installed)Table 1 PTAC/UH-33-A— Field Installed Control Options (See Tables PTAC/UH-33-A, PTAC/UH-33-B,PTAC/UH-34-A for Control Prices)Unit Thermostat LouverMounted Summer w/Summer ConeDisconnect F<strong>an</strong> F<strong>an</strong> Stratification Mounting DiffuserUnit Switch Thermostats Switches Switch Thermostat Brackets 7.50-50 kWOrder Single- Three- Unit Wall Unit Wall Wall Unit Wall vertNumber Phase Phase MTD 2 MTD MTD MTD MTD MTD MTD vert horiz only236- 172 -700* NA -705* -714* -711* -719 NA -710* -718 -726* -723* NA174 -700* NA -705* -714* -711* -719 NA -710* -718 -726* -723* NA246 700* NA 705* 716* 711* -720 NA 710* 718 726* 723* NA176 -700* -701* -705 3 * -714 7 * -711* -719 NA -710* -718 -726* -723* NA178 -700* -701* -705 3 * -714 7 * -711* -719 NA -710* -718 -726* -723* NA180 -700* NA -705* -714* -711* -719 NA -NA -718 -726* -723* NA248 -700* NA -705* -716* -711* -720* NA -710* -718 -726* -723* NA182 NA -701* -705* -716* -712* -720* -721 -709 NA -726* -723* NA236- 184 -700* NA -705* -714* -711* -719 NA -710* -718 -726* -723* NA250 -700* -701* -705 3 * -716* -711* 719 NA -710* -718 -726* -723* NA186 -700* NA -705* -714* -711* -719 NA -710* -718 -726* -723* NA188 -700* -701* -705 3 * -714 7 * -711* -719 NA -710* -718 -726* -723* NA190 -700* -701* -705 3 * -714 7 * -711* -719 NA -710* -718 -726* -723* NA252 -700* -701 -705 3 * -716* -711* 719 NA -710* -718 -726* -723* NA192 -700* NA -705* -714* -711* -719 NA NA -718 -726* -723* NA194 NA -701* -705* -716* -712* -720* -721 -709 NA -726* -723* NA236-196 -703 -704 -705* -716* -711* 719 -721 -710* -718 -727* -724* -920*198 -703 -702* -705* -716* -711* 719 -721 -710* -718 -727* -724* -920*200 -703 — -705* -716* -711* 719 -721 -NA -718 -727* -724* -920*202 NA -701* -705* -716* -712* -720* -721 -709 NA -727* -724* -920*236- 204 -703 -702* -705* -716* -711* 719 -721 -710* -718 -727* -724* -920*206 -703 -702* -705* -716* -711* 719 -721 -710* -718 -727* -724* -920*208 -703 NA -705* -716* -711* 719 -721 -NA -718 -727* -724* -920*210 NA -701* -705* -716* -712* -720* -721 -709 NA -727* -724* -920*236- 212 NA -704 -705* -716* -711* 719 -721 -710* -718 -727* -724* -920*214 NA -704 -705* -716* -711* 719 -721 -710* -718 -727* -724* -920*216 NA -701* -705* -716* -712* -720* -721 -709 NA -727* -724* -920*236- 218 NA -704 -705* -716* -711* 719 -721 -710* -718 -727* -724* -920*220 NA -702* -705* -716* -712* -720* -721 -709 NA -727* -724* -920*236- 222 NA NA -705 4 * -716 5 * -711* 719 -721 6 -710* -718 -728* -725* -922*224 NA -704 -705 4 * -716 5 * -711* 719 -721 6 -710* -718 -728* -725* -922*226 NA -702* -705 4 * -716 5 * -712* -720* -721 6 -709 NA -728* -725* -922*236- 228 NA NA -705 4 * -716 5 * -711* 719 -721 6 -710* -718 -728* -725* -922*232 NA -704 -705 4 * -716 5 * -712* -720* -721 6 -709 NA -728* -725* -922*236 NA NA -705 4 * -716 5 * -711* 719 -721 6 -710* -718 -728* -725* -922*238 NA -704 -705 4 * -716 5 * -712* -720* -721 6 -709 NA -728* -725* -922*236- 244 NA -704 -705 4 * -716 5 * -712 -720* -721 6 -709 NA -728* -725* -922*Notes:1. Three-phase electric unit heaters need two-pole thermostats for line voltage service.2. Unit mounted controls are always field installed by others.3. For three-phase operation use 236-706.4. For two-stage operation use 236-708.5. For two-stage operation use 236-717.6. For two-stage operation use 236-722.7. For three-phase operation use 236-715.These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)PTAC/UH-33 Effective 1/1/06


Electric Unit HeatersControl Options(Field Installed)Table PTAC/UH-34-A— Control Options (Unit Mounted in Field)Model No. Order No. DescriptionPower Disconnect Switch (Unit Mounted) 1DCS 252 236-700 2 Pole 25 Amp 120-277 VAC Res.DCS 253 236-701 3 Pole 25 Amp 120-600 VAC Res.DCS 323 236-702 3 Pole 32 Amp 120-600 VAC Res.DCS 632 236-703 2 Pole 63 Amp 120-600 VAC Res.DCS 633 236-704 3 Pole 63 Amp 120-600 VAC Res.Line Voltage Thermostats (Unit Mounted)T5100 236-705 SPST 25 Amp 120-277V 45 - 90°F 2T5102 236-706 DPST 25 Amp 120-277V 45 - 90°F 3Low Voltage Thermostats 24VT5100R 236-705 SPST Low Voltage 24V 45 - 90°F (3-20 kW units) (single-stage)T5122 236-708 Two-stage Low Voltage 24V 45 - 90°F (25-50 kW units)Stratification Thermostat 4TC5102 236-709 SPST Low Volt-Pilot 24V Duty (w/relay) 70 - 130°F 5TC5103 236-710 SPST Line Voltage 120/277V 70 - 130°F 6Summer F<strong>an</strong> SwitchFS5101 236-711 SPST Line Voltage 120-277VFS5102 236-712 SPST Line Voltage 120-600VNotes:1. Use two pole disconnect switch only for single-phase operation <strong>an</strong>d a three pole disconnect switch only for three-phase operation. Both are factory installed.2. Ok for single or three-phase.3. Must be used on dual (single to three-phase) units when three-phase is required. Ok to use on single or three-phase units.4. Wall thermostat must be used when unit mounted stratification thermostat is required. The stratification thermostat activates the f<strong>an</strong> only for heat recovery.5. To be used on 480V three-phase units only. Not available for 277V single-phase units.6. Not available for 480V three-phase <strong>an</strong>d 277V single-phase units only.Table PTAC/UH-34-B— Control Options (Wall Mounted)Model No. Order No. DescriptionLine Voltage ThermostatsTW1510 236-714 SPST 30 amp 120-240V 25 Amp 277V 40 - 90°F 1TW1512 236-715 DPST 30 amp 120-240V 25 Amp 277V 40 - 90°F 2Low Voltage ThermostatA6176 236-716 SPST 24V 50 - 80°FTW123 236-717 Two-stage 24V 45 - 85°F (25-50 kW units)Stratification ThermostatTC1602 236-718 SPST Line Voltage 120-240V 70 - 140°F 3Summer F<strong>an</strong> SwitchFSW5111 236-719 SPST Line Voltage 120-600VFSW5112 236-720 SPST Low Voltage w/relay 24VLow Voltage T’stat w/Summer F<strong>an</strong> SwitchTFS5101 236-721 SPST Low Voltage 40 - 90°F 4 , 6TFS5102 236-722 Two-stage Low Voltage 45 - 85°F 24V 51. Must be used on single-phase units only.2. Ok for use on single or three-phase units.3. Do not use with 480V three-phase units only.4. Not available for 3.3 <strong>an</strong>d 5.0 kW, 208/1, 277/1, 240/208/1, 208/1-3 units must have tr<strong>an</strong>sformer <strong>an</strong>d contactor to be ok <strong>an</strong>d 240/208/1-3V/phase units. Ok for use on 3.3 <strong>an</strong>d 5.0 480/3 volt/phase units. All 7.5 thru 50 kW size units, volts <strong>an</strong>d phase units are ok.5. For use on 25 - 50 kW size units only.6. Comes with a relay as st<strong>an</strong>dard, c<strong>an</strong> be factory installed if shown on the order.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)Effective 1/1/06PTAC/UH-34These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.


Electric Unit HeatersAccessoriesTable PTAC/UH-35-A—AccessoriesModel No. Order No. Description wt. lbs.Wall/Ceiling Mounting Bracket (horiz. discharge)A5105 236-723 2-5 kW Bracket 6.0A5120 236-724 7-20 kW Bracket 9.0A5150 236-725 25-50 kW Bracket 11.0Dust Shield (horiz. discharge)DS5105 233-740 3.3-5 kW Dust Shield .5DS5120 233-741 7.5-20 kW Dust Shield .5DS5150 233-742 25-50 kW Dust Shield .5Ceiling Mtg. Bracket (vert. discharge)V5105 236-726 2-5 kW Bracket 9.0V5120 236-727 7-20 kW Bracket 13.0V5150 236-728 25-50 kW Bracket 13.0Louver Cone Diffusers (vert. discharge only)RD5120 236-920 7-20 kW Diffuser 8.0RD5150 236-922 25-50 kW Diffuser 12.0Anemostat Diffusers (vert. discharge only)AD5120 233-730 7-20 kW ANEMOSTAT 9.0AD5150 233-731 25-50 kW ANEMOSTAT 13.0Table PTAC/UH-35-B—OSHA F<strong>an</strong> GuardsOFG5101 233-930 3-5 kWOFG5102 233-932 7-20 kWOFG5103 233-935 25-50 kWThese items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)PTAC/UH-35 Effective 1/1/06


Electric Unit HeatersHose Down Corrosion Resist<strong>an</strong>tTable PTAC/UH-36-A— Hose Down Corrosion Resist<strong>an</strong>t Unit HeaterskW Order No. Element & ShipRating UHRA 233 Element Phase Motor Voltage Amp Rating wt. lbs031AAAT -600 1 208 15.9033AAAT -602 3 208 9.2031GAAT -603 1 240 13.83.3 kW 033GAAT -604 3 240 8.0 45031CAAT -606 1 277 12.0033DAAT -608 3 480 4.0033FAAT -609 3 600 3.2051AAAT -610 1 208 24.1053AAAT -612 3 208 13.9051GAAT -614 1 240 20.95.0 kW 053GAAT -615 3 240 12.1 45051CAAT -616 1 277 18.1053DAAT -617 3 480 6.1053FAAT -618 3 600 4.9071AAAT -620 1 208 36.1073AAAT -621 3 208 20.9071GAAT -623 1 240 31.37.5 kW 073GAAT -625 3 240 18.1 45071CAAT -626 1 277 27.1073DAAT -627 3 480 9.1073FAAT -629 3 600 7.3101AAAT -631 1 208 48.1103AAAT -633 3 208 27.8101GAAT -634 1 240 41.710 kW 103GAAT -635 3 240 24.1 55101CAAT -637 1 277 36.2103DAAT -638 3 480 12.1103FAAT -639 3 600 9.7151AAAT -651 1 208 72.2153AAAT -653 3 208 41.7151GAAT -654 1 240 62.515 kW 153GAAT -655 3 240 36.2 55153DAAT -658 3 480 18.1153FAAT -659 3 600 14.5203AAAT -660 3 208 55.620 kW 203GAAT -662 3 240 48.2 85203DAAT -664 3 480 24.1203FAAT -666 3 600 19.3253AAAT -661 3 208 69.525 kW 253GAAT -663 3 240 60.3 85253DAAT -665 3 480 30.2253FAAT -667 3 600 24.1303AAAT -670 3 208 83.430 kW 303GAAT -672 3 240 72.3 85303DAAT -673 3 480 36.2303FAAT -674 3 600 29.040 kW 403DAAT -677 3 480 48.2 130403FAAT -678 3 600 38.648 kW 483DAAT -685 3 480 57.9 130483FAAT -687 3 600 46.31. Includes as st<strong>an</strong>dard the following controls factory installed <strong>an</strong>d wired. (24V tr<strong>an</strong>sformer, pilot light, thermostat, heat- off-f<strong>an</strong> switch, f<strong>an</strong> delay relay <strong>an</strong>d disconnect.)2. Corrosion-resist<strong>an</strong>t in high humidity <strong>an</strong>d water-saturated areas in non-hazardous locations <strong>an</strong>d atmospheres.3. 15 kW, 277V single-phase heaters are not available.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)Effective 1/1/06PTAC/UH-36These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.


Electric Unit HeatersAccessoriesTable PTAC/UH-37-A— AccessoriesModel No. Order No. Description wt. lbs.Wall Mounting KitA5520 233-690 3.3-15 kW Bracket 1W5520 233-691 3.3-15 kW Bracket 2 28W5550 233-692 20-48 kW Bracket 2Ceiling Mtg. Kit 3H5550 233-694 3.3-48 kW H<strong>an</strong>ging Bracket. 6Pipe Mtg. Kit 4P5520 233-695 3.3-15 kW BracketP5550 233-696 20-48 kW Bracket 391. One piece bracket for wall mounting for sizes 3.3-15 kW only. M<strong>an</strong>ufactured from stainless steel <strong>an</strong>d epoxy coated.2. Contains wall bracket <strong>an</strong>d mounting arm, ideal for use in buildings that have subst<strong>an</strong>tial walls. Arm only c<strong>an</strong> also be bolted directly to structural steel. M<strong>an</strong>ufactured from cast iron steel <strong>an</strong>depoxy coated.3. Requires Roof or Ceiling Structure. ½” pipe, cut <strong>an</strong>d threaded is required furnished by others.4. 3 ½” pipe 4” O.D. supplied by others.These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)PTAC/UH-37 Effective 1/1/06


Electric Unit HeatersUHXATable PTAC/UH-38-A— UHXA with 24V Control Voltage 1kW Order No. Element + Mtr Amp ControlRating UHXA 233- Volts/Phase Rating Voltage wt. lbs.031A1B -110 208/1 16.3 24 167033A1B -112 208/3 9.8 24 1673 kW 031B1B -114 240/1 14.8 24 167033B1B -116 240/3 8.6 24 167033D1B -118 480/3 4.3 24 167033F1B -119 600/3 3.5 24 167051A1B -120 208/1 26.0 24 167053A1B -122 208/3 15.4 24 1675 kW 051B1B -124 240/1 23.1 24 167053B1B -126 240/3 13.4 24 167053D1B -128 480/3 6.7 24 167053F1B -129 600/3 5.4 24 167071A1B -130 208/1 38.0 24 167073A1B -132 208/3 22.3 24 1677.5 kW 071B1B -134 240/1 33.6 24 167073B1B -136 240/3 19.4 24 167073D1B -138 480/3 9.7 24 167073F1B -139 600/3 7.8 24 167103A1B -140 208/3 29.3 24 193101B1B -142 240/1 44.0 24 19310 kW 103B1B -144 240/3 25.5 24 193103D1B -146 480/3 12.7 24 193103F1B -148 600/3 10.2 24 193153A1B -150 208/3 43.5 24 22515 kW 153B1B -151 240/3 38.1 24 225153D1B -152 480/3 19.0 24 225153F1B -153 600/3 15.2 24 22520 kW 203D1B -154 480/3 25.1 24 225203F1B -155 600/3 20.0 24 22525 kW 253D1B -156 480/3 31.1 24 225253F1B -157 600/3 24.9 24 225*Supply conductors must be suitable for 90°C1. 24V control voltage is st<strong>an</strong>dard <strong>an</strong>d includes built-in contactor <strong>an</strong>d 24V control tr<strong>an</strong>sformer.Table PTAC/UH-38-B— UHXA with 120V Control VoltagekW Order No. Element + Mtr Amp ControlRating UHXA 233- Volts/Phase Rating Voltage wt. lbs.031A2B -111 208/1 16.3 120 167033A2B -113 208/3 9.8 120 1673 kW 031B2B -115 240/1 14.8 120 167033B2B -117 240/3 8.6 120 167033D2B -121 480/3 4.3 120 167051A2B -125 208/1 26.0 120 167053A2B -127 208/3 15.4 120 1675 kW 051B2B -131 240/1 23.1 120 167053B2B -133 240/3 13.4 120 167053D2B -135 480/3 6.7 120 167071A2B -141 208/1 38.0 120 167073A2B -143 208/3 22.3 120 1677 kW 071B2B -145 240/1 33.6 120 167073B2B -147 240/3 19.4 120 167073D2B -149 480/3 9.7 120 167103A2B -159 208/3 29.3 120 193101B2B -160 240/1 44.0 120 19310 kW 103B2B -161 240/3 25.5 120 193103D2B -162 480/3 12.7 120 193153A2B -164 208/3 43.5 120 22515 kW 153B2B -165 240/3 38.1 120 225153D2B -166 480/3 19.0 120 22520 kW 203D2B -168 480/3 25.1 120 22525 kW 253D2B -170 480/3 31.1 120 225* Supply conductors must be suitable for 90°C1. 120V control voltage is st<strong>an</strong>dard <strong>an</strong>d includes built-in contactor <strong>an</strong>d 120V control tr<strong>an</strong>sformer.2. Not available for 600V heaters.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)Effective 1/1/06PTAC/UH-38These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.


Electric Unit HeatersUHXA Control Options MountingBracket KitsTable PTAC/UH-39-A—UHXA with 208 or 240 Volt Control VoltagekW Order No. Element + Mtr Amp ControlRating UHXA 233- Volts/Phase Rating Voltage wt. lbs.031A3B -260 208/1 16.3 208 167033A3B -262 208/3 9.8 208 1673 kW 031B4B -264 240/1 14.8 240 167033B4B -266 240/3 8.6 240 167051A3B -268 208/1 26.0 208 167053A3B -270 208/3 15.4 208 1675 kW 051B4B -272 240/1 23.1 240 167053B4B -274 240/3 13.4 240 167071A3B -276 208/1 38.0 208 167073A3B -278 208/3 22.3 208 1677 kW 071B4B -280 240/1 33.6 240 167073B4B -282 240/3 19.4 240 167103A3B -284 208/3 29.3 208 19310 kW 101B4B -286 240/1 44.0 240 193103B4B -288 240/3 25.5 240 193153A3B -290 208/3 43.5 208 22515 kW 153B4B -292 240/3 38.1 240 225* Supply conductors must be suitable for 90°C1. Not available for 480 <strong>an</strong>d 600 volt heaters.Table PTAC/UH-39-B—Unit Mounted Control Option (Factory Installed)Model No. Order No. DescriptionUnit Mounted ThermostatT 233-010 Explosion Proof 45-90°F1. Will operate on all voltages.Table PTAC/UH-39-C—Wall Mounted Control OptionModel No. Order No. Description wt. lbs.TW161 233-015 Explosion Proof Thermostat SPST 40-90°F 22 Amps, 5125-277 VAC ¾ HP @ 125 VAC, 1½ HP @ 250-277 VAC*TW162 233-019 Explosion Proof Thermostat DPST 40-90°F 22 Amps, 5125-277 VAC ¾ HP @ 125 VAC, 1½ HP @ 250-277 VAC** Makes on fall in the temperature.OK for use on units with 24V <strong>an</strong>d 120V control voltage.Table PTAC/UH-39-D—Mounting Bracket KitsModel No. Order No. Description wt. lbs.Wall Mounting Bracket 1HLWM37 233-020 3, 5 <strong>an</strong>d 7.5 kW Bracket 27HLWM10 233-022 10 kW Bracket 28HLWM1525 233-026 15, 20 <strong>an</strong>d 25 kW Bracket 29Ceiling Mounting Bracket 2HLHM 233-033 All Sizes 5Floor Mounting Bracket 3HLPM37 233-041 3, 5 <strong>an</strong>d 7.5 kW Bracket 37HLPM10 233-044 10 kW Bracket 38HLPM1525 233-049 15, 20 <strong>an</strong>d 25 kW Bracket 401. Wall Bracket, ideal for use in buildings that have subst<strong>an</strong>tial walls. Note: The arm only c<strong>an</strong> be bolted directly to structural steel.2. Ceiling Mounting Bracket - Must have adequate overhead structure to mount to. Note: ½” pipe, cut <strong>an</strong>d threaded <strong>an</strong>d supplied by others is required.3. Floor Mounting Bracket should be used in buildings with insufficient strength to use other types of mounting brackets.To be used with 3½” schedule 40 pipe (4 OD supplied by others).These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)PTAC/UH-39 Effective 1/1/06


Electric Unit HeatersCeiling Heaters, Plaster Trim <strong>an</strong>dThermostatsTable PTAC/UH-40-A—Series 70 Electric Ceiling Surface HeaterskW Order No. Element + Element Mounting AmpRating UHCA 233- Motor Voltage Phase Application Rating021A7A -300 208 1 Surface 9.62 kW 021B7A -302 240 1 Surface 8.3021C7A -304 277 1 Surface 7.2031A7A -306 208 1 Surface 14.43 kW 031B7A -308 240 1 Surface 12.5031C7A -310 277 1 Surface 10.8041A7A -312 208 1 Surface 19.2041B7A -314 240 1 Surface 16.74 kW 041C7A -316 277 1 Surface 14.4043A7A -318 208 3 Surface 11.1043B7A -320 240 3 Surface 9.6051A7A -322 208 1 Surface 24.1051B7A -324 240 1 Surface 20.85 kW 051C7A -326 277 1 Surface 18.1053A7A -328 208 3 Surface 13.9053B7A -330 240 3 Surface 12.1Surface Mounted Ceiling Heaters — Series 70 designed to be mounted to st<strong>an</strong>dard 4 inch ceiling box furnished <strong>an</strong>d installed by others. Approximate weight 32 lbs. Packed <strong>an</strong>d shipped ascomplete unit.Table PTAC/UH-40-B—Series 80 Electric Ceiling Recessed HeaterskW Order No. Element + Element Mounting AmpRating UHCA 233- Motor Voltage Phase Application Rating021A8A -331 208 1 Recessed 9.62 kW 021B8A -333 240 1 Recessed 8.3021C8A -335 277 1 Recessed 7.2031A8A -337 208 1 Recessed 14.43 kW 031B8A -339 240 1 Recessed 12.5031C8A -341 277 1 Recessed 10.8041A8A -343 208 1 Recessed 19.2041B8A -345 240 1 Recessed 16.74 kW 041C8A -347 277 1 Recessed 14.4043A8A -349 208 3 Recessed 11.1043B8A -351 240 3 Recessed 9.6051A8A -353 208 1 Recessed 24.1051B8A -355 240 1 Recessed 20.85 kW 051C8A -357 277 1 Recessed 18.1053A8A -359 208 3 Recessed 13.9053B8A -361 240 3 Recessed 12.1Recessed Mounted Ceiling Heaters — Series 80 packed <strong>an</strong>d shipped as a complete unit. Contains junction box, heater box <strong>an</strong>d grille.For finished ceiling application use plaster trim which is <strong>an</strong> optional accessory. Approximate weight 35 lbs.Table PTAC/UH-40-C—Plaster TrimModel No. Order No. Description*PT3480 233-363 Plaster Trim*Use PT3480 plaster trim for Series 80 recessed heaters when recessed in a hard finished ceiling.Table PTAC/UH-40-D—Line Voltage Thermostats (Wall Mounted)Model No. Order No. Description*TW148 233-301 DPST 25 AMP 120-240V, 18 Amp 277V for single-phase*TW146 233-303 DPST 25 AMP 120-240V, 18 Amp 277V, Tamper Resist<strong>an</strong>t for single-phase**TW1512 233-715 DPST 30 AMP 120-240V, 25 Amp 277V, 40-90°F for 3 PhaseTW147 233-311 SPST 25 AMP 120-240V, 18 Amp 277V, Pilot Duty for use with Remote ContactorsTW145 233-313 SPST 25 AMP 120-240V, 18 Amp 277V, Pilot Duty for use with Remote Contactors,Tamper Resist<strong>an</strong>t*For use with one unit single phase <strong>an</strong>d more th<strong>an</strong> one unit single-phase. Makes <strong>an</strong>d breaks two poles simult<strong>an</strong>eously.**For use with one unit three phase only <strong>an</strong>d more th<strong>an</strong> one unit three or single-phase. Do not exceed thermostat’s rated ampacity.Makes <strong>an</strong>d breaks two poles simult<strong>an</strong>eously. Three phase units with TW1512 line voltage thermostat does not need a control p<strong>an</strong>el.Table PTAC/UH-40-E—Low Voltage Thermostat (Wall Mounted)Model No. Order No. Description*A6176 236-716 Deluxe 24V, Adjustable Anticipation Positive Off Switch, Thermometer, Honeywell T87FA6280 233-323 Tamperproof Kit for A6176*Three-phase units must have a control p<strong>an</strong>el when used with a wall mounted low voltage thermostat.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)Effective 1/1/06PTAC/UH-40These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.


Electric Unit HeatersThermal Relay, Control P<strong>an</strong>elsTable PTAC/UH-41-A—Thermal Relay with Built-in Line Voltage/24V Tr<strong>an</strong>sformer*Model No. Order No. DescriptionA6281 233-370 120, 208, 240 or 277V (Specify Voltage) SPSTA6283 233-373 120, 208, 240 or 277V (Specify Voltage) 2 Circuit*For remote mounting only, for use with low voltage A6176 thermostat.Table PTAC/UH-41-B—Control P<strong>an</strong>els — 24V*Model No. Order No. Primary Voltage Dimensions No. Of ContactorsAF3401-24 233-332 208AH3401-24 233-334 240 12”x12”x4 ½” 1AG3401-24 233-336 277AF3402-24 233-338 208AH3402-24 233-340 240 15”x15”x4 ½” 2AG3402-24 233-342 277AF3403-24 233-344 208AH3403-24 233-346 240 20”x20”x4 ½” 3AG3403-24 233-348 277*For control of one or more single or three phase ceiling heaters from one 24V thermostat. P<strong>an</strong>els are in NEMA one enclosures <strong>an</strong>d have one or more 30 Amp, three pole, 600 VACcontactor(s), operating voltage to control voltage tr<strong>an</strong>sformer <strong>an</strong>d tr<strong>an</strong>sformer fusing. (User must provide separate circuit for each contactor.)Table PTAC/UH-41-C—Control P<strong>an</strong>els — 120V*Model No. Order No. Primary Voltage Dimensions No. of ContactorsAF3401-120 233-350 208AH3401-120 233-352 240 12”x12”x4 ½” 1AG3401-120 233-354 277AF3402-120 233-356 208AH3402-120 233-358 240 15”x15”x4 ½” 2AG3402-120 233-360 277AF3403-120 233-362 208AH3403-120 233-364 240 20”x20”x4 ½” 3AG3403-120 233-366 277*For control of one or more single or three phase ceiling heaters from one 120V thermostat. P<strong>an</strong>els are in NEMA one enclosures <strong>an</strong>d have one or more 30 Amp, three pole, 600 VACcontactor(s), operating voltage to control voltage tr<strong>an</strong>sformer <strong>an</strong>d tr<strong>an</strong>sformer fusing. (User must provide separate circuit for each contactor.)CONTROL PANELS — 1-PHASE ELECTRIC CEILING HEATERS1 – Contactor h<strong>an</strong>dle 3 Units.2 – Contactors h<strong>an</strong>dle 6 Units.3 – Contactors h<strong>an</strong>dle 9 Units.Note: Make sure you do not exceed total ampacity rating.3-PHASE ELECTRIC CEILING HEATERS1 – Contactor h<strong>an</strong>dle 1 Unit.2 – Contactors h<strong>an</strong>dle 2 Units.3 – Contactors h<strong>an</strong>dle 3 Units.Note: Make sure you do not exceed total ampacity rating.Note: Each control p<strong>an</strong>el uses three pole contactors rated at 30 Amps per pole.Table PTAC/UH-41-D—Unit Mounted Controls for Series 80 Ceiling Heaters OnlyModel No. Order No. DescriptionT2 233-382 Thermostat Double PoleS 233-383 Disconnect SwitchR1 233-385 24V Tr<strong>an</strong>sformer/RelayR 233-387 Line Voltage RelayR2 233-389 120V Relay1. All controls factory installed <strong>an</strong>d wired on the heaters.2. Thermostats are tamperproof.3. F<strong>an</strong> purge (off delay to dissipate residual heat on shutoff) supplied as a st<strong>an</strong>dard control on heaters with factory installed options.These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)PTAC/UH-41 Effective 1/1/06


Electric Unit HeatersElectric Wall MountedTable PTAC/UH-42-A—Electric Wall Mounted Unit Heaters — Series 20 'Order ElementkW No. + Motor Element Ship AmpRating UHWA 233- 2 Voltage Phase Amps wt. lbs. Rating021A2AT -400 208 1 9.6 9.62000W 021B2AT -402 240 1 8.3 41 8.3021C2AT -404 277 1 7.2 7.2031A2AT -406 208 1 14.4 14.43000W 031B2AT -408 240 1 12.5 41 12.5031C2AT -410 277 1 10.8 10.8041A2AT -412 208 1 19.2 19.2041B2AT -414 240 1 16.7 16.74000W 041C2AT -416 277 1 14.4 41 14.4043A2AT -418 208 3 11.1 11.1043B2AT -420 240 3 9.6 9.6051A2AT -422 208 1 24.0 24.1051B2AT -424 240 1 20.8 20.85000W 051C2AT -426 277 1 18.0 41 18.1053A2AT -428 208 3 13.9 13.9053B2AT -430 240 3 12.0 12.1All Sizes 3420 -440 Wall Box5 9 —1. Only contactor c<strong>an</strong> be built-in on Series 20 Wall Heaters.2. Factory installed (T) thermostat is st<strong>an</strong>dard.3. Wall box must be ordered.Table PTAC/UH-42-B—Electric Wall Mounted Unit Heaters without Unit Mounted ThermostatOrder ElementkW No. + Motor Element Ship AmpRating UHWA 233- 2 Voltage Phase Amps wt. lbs. Rating021A2A0 n/a 208 1 9.6 9.62000W 021B2A0 n/a 240 1 8.3 41 8.3021C2A0 n/a 277 1 7.2 7.2031A2A0 n/a 208 1 14.4 14.43000W 031B2A0 n/a 240 1 12.5 41 12.5031C2A0 n/a 277 1 10.8 10.8041A2A0 n/a 208 1 19.2 19.2041B2A0 n/a 240 1 16.7 16.74000W 041C2A0 n/a 277 1 14.4 41 14.4043A2A0 n/a 208 3 11.1 11.1043B2A0 n/a 240 3 9.6 9.6051A2A0 n/a 208 1 24.0 24.1051B2A0 n/a 240 1 20.8 20.85000W 051C2A0 n/a 277 1 18.0 41 18.1053A2A0 n/a 208 3 13.9 13.9053B2A0 n/a 240 3 12.0 12.1All Sizes 3420 233-440 Wall Box5 91. Only contactor c<strong>an</strong> be built-in on Series 20 Wall Heaters.2. Wall box must be ordered.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)Effective 1/1/06PTAC/UH-42These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.


Electric Unit HeatersElectric Wall Mounted <strong>an</strong>dExtension SleevesTable PTAC/UH-43-A— Electric Wall Mounted Unit Heaters — Series 50 1Order ElementkW No. + Motor Element Ship AmpRating UHWA 233- 2 Voltage Phase Amps wt. lbs. Rating021A5AT -431 208 1 9.6 9.62000W 021B5AT -433 240 1 8.3 54 8.3021C5AT -435 277 1 7.2 7.2031A5AT -437 208 1 14.4 14.43000W 031B5AT -439 240 1 12.5 55 12.5031C5AT -441 277 1 10.8 10.8041A5AT -443 208 1 19.2 19.2041B5AT -445 240 1 16.7 16.74000W 041C5AT -447 277 1 14.4 55 14.4043A5AT -449 208 3 11.1 11.1043B5AT -451 240 3 9.6 9.6051A5AT -453 208 1 24.0 24.1051B5AT -455 240 1 20.8 20.85000W 051C5AT -457 277 1 18.0 55 18.1053A5AT -459 208 3 13.9 13.9053B5AT -461 240 3 12.0 12.1All Sizes 3450 -450 Wall Box5 11 —1. If circuit breaker <strong>an</strong>d/or tr<strong>an</strong>sformers are required, the Series 50 wall heater must be ordered.2. Factory installed (T) thermostat is st<strong>an</strong>dard.3. Wall box must be ordered.Table PTAC/UH-43-B— Electric Wall Mounted Unit Heaters without Unit Mounted ThermostatOrder ElementkW No. + Motor Element Ship AmpRating UHWA 233- 2 Voltage Phase Amps wt. lbs. Rating021A5A0 n/a 208 1 9.6 9.62000W 021B5A0 n/a 240 1 8.3 54 8.3021C5A0 n/a 277 1 7.2 7.2031A5A0 n/a 208 1 14.4 14.43000W 031B5A0 n/a 240 1 12.5 55 12.5031C5A0 n/a 277 1 10.8 10.8041A5A0 n/a 208 1 19.2 19.2041B5A0 n/a 240 1 16.7 16.74000W 041C5A0 n/a 277 1 14.4 55 14.4043A5A0 n/a 208 3 11.1 11.1043B5A0 n/a 240 3 9.6 9.6051A5A0 n/a 208 1 24.0 24.1051B5A0 n/a 240 1 20.8 20.85000W 051C5A0 n/a 277 1 18.0 55 18.1053A5A0 n/a 208 3 13.9 13.9053B5A0 n/a 240 3 12.0 12.1All Sizes 3450 233-450 Wall Box5 111. If circuit breaker <strong>an</strong>d/or tr<strong>an</strong>sformers are required, the Series 50 wall heater must be ordered.2. Wall box must be ordered.Table PTAC/UH-43-C— Extension SleevesModel No. Order No. Series Unit Description3420EX34 3 233-401 20 4½” extension sleeve for full surface mtg3420EX16 1 233-403 20 2” extension sleeve for semi-recess mtg3420EX8 2 233-405 20 1” extension sleeve for semi-recess mtg3450EX34 3 233-407 50 4½” extension sleeve for full surface mtg3450EX16 1 233-409 50 2” extension sleeve for semi-recess mtg3450EX8 2 233-411 50 1” extension sleeve for semi-recess mtg1. For extending front additional 2” from finished wall. Heater recesses 2¼”.2. For extending front additional 1” from finished wall. Heater recesses 3¼”. Shipping weight for sleeves is 5 lbs.3. Must be used when heater c<strong>an</strong> not be fully or semi recessed into the wall.These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)PTAC/UH-43 Effective 1/1/06


Electric Unit HeatersControl Options (Factory Installed)Line Voltage ThermostatsTable PTAC/UH-44-A— Control Options Factory InstalledModel No. OrderNo. Series Unit DescriptionR 233-415 20 + 50 Built-in contactor holding coil same as heater voltage.R1 233-417 20 + 50 Built-in Contactor 24V Holding CoilR2 233-419 20 + 50 Built-in Contactor 120V Holding CoilC 233-425 50 Circuit Breaker (Series 50 only) arr<strong>an</strong>ged to be disconnected beforeremoval of front with line side terminals covered for safe mainten<strong>an</strong>ce.Additional control circuit switch installed if required.A1 1 233-427 50 Built-in control tr<strong>an</strong>sformer (Series 50 only) 24V secondary.A2 1 233-429 50 Built-in control tr<strong>an</strong>sformer (Series 50 only) 120V secondary availableon all three-phase heaters, up to 3 kW on 208V <strong>an</strong>d 240V, singlephase<strong>an</strong>d up to 4 kW on 277V, single-phase.1. Contactor must be ordered with tr<strong>an</strong>sformer.Table PTAC/UH-44-B— Line Voltage Thermostats (Wall Mounted)Model No. Order No. DescriptionTW148 1 233-301 DPST 25 Amp 120-240V, 18 Amp 277V for single-phaseTW146 1 233-303 DPST 25 Amp 120-240V, 18 Amp 277V, Tamper Resist<strong>an</strong>t for single-phaseTW1512 2 233-715 DPST 30 Amp 120-240V, 25 Amp 277V, 40-90°F for three-phaseTW147 233-311 SPST 25 Amp 120-240V, 18 Amp 277V, Pilot Duty for use with Remote ContactorsTW145 233-313 SPST 25 Amp 120-240V, 18 Amp 277V, Pilot Duty for use with Remote Contactors,Tamper Resist<strong>an</strong>t1. For use with one unit single-phase <strong>an</strong>d more th<strong>an</strong> one unit single-phase. Makes <strong>an</strong>d breaks two poles simult<strong>an</strong>eously.2. For use with one unit three-phase only <strong>an</strong>d more th<strong>an</strong> one unit three or single-phase. Do not exceed thermostats rated ampacity. Makes <strong>an</strong>d breaks two poles simult<strong>an</strong>eously.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)Effective 1/1/06PTAC/UH-44These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.


Electric Unit HeatersWall Heater <strong>an</strong>d AccessoriesTable PTAC/UH-45-A—Electric Architectural Forced Air Wall Heater 1Model No. Order No. Element +Motor Element kW ShipWatts UHAA 2 233- 2 Voltage Phase Rating wt. lbs.151ETAD -500 120 11500 151BTAD -512 240 1 1.5 26151ATAD -502 208 1151CTAD -522 277 1 1.5 26021BTAD -514 240 12000 021ATAD -504 208 1 2.0 27021CTAD -524 277 1 2.0 27031BTAD -516 240 13000 031ATAD -506 208 1 3.0 29031CTAD -526 277 1 3.0 29041BTAD -518 240 14000 041ATAD -508 208 1 4.0 29041CTAD -528 277 1 4.0 29481BTAD -520 240 14800 481ATAD -510 208 1 4.8 29481CTAD -530 277 1 4.8 291. 3310 Wall Box is st<strong>an</strong>dard part of the Wall Heater.2. All Wall Heaters shipped as st<strong>an</strong>dard with factory installed tamperproof thermostat, f<strong>an</strong> delay <strong>an</strong>d disconnect switch.Table PTAC/UH-45-B—Suface Mounting Adapter 1Model No. Order No. Description3320 EX 33 233-501 Surface Mounting Adapter1. Field installed.2. Order as a separate item.Table PTAC/UH-45-C—Day/Night Relay 1Model No. Order No. DescriptionR 233-505 Day/Night Relay1. Factory installed only.2. Order as a separate item.These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)PTAC/UH-45 Effective 1/1/06


Electric Unit HeatersElectric Wall FinElectric Wall Fin - OrderingInformation1. Electric wall fin units with painted enclosuresare available. Please contact St. LouisCustomer Service for more information.2. Electric wall fin units with <strong>an</strong>odized aluminumfronts <strong>an</strong>d (or) <strong>an</strong>odized aluminum outlet grilles<strong>an</strong>d accessories are available. Please contactSt. Louis Customer Service for moreinformation.3. Bl<strong>an</strong>k enclosure sections only with paintedsteel fronts <strong>an</strong>d painted aluminum outlet grillesare available. Please contact St. LouisCustomer Service for more information.Table PTAC/UH-46-A—Heater with Electric Element <strong>an</strong>d Enclosurelbs.Model No. Dimensions per ft.DBT 6” High x 3½” dp 4.0DBF 6” High x 3½” dp 4.0CB 4½” High x 2 5/8 ” dp 3.0DBCT 7” High x 5” dp 5.0DBCF 7” High x 5” dp 5.0RDBT-PD 5” High x 6” dp 5.0ASHDB 8” High 7.510” High 8.512” High 9.514” High x 5½” dp 10.516” High 11.518” High 12.520” High 13.51. Includes Heating Element, Thermal Overload, Front P<strong>an</strong>el <strong>an</strong>d Back P<strong>an</strong>el.2. Model ASHDB furnished with steel front p<strong>an</strong>els.Table PTAC/UH-46-B—Maximum Watts/FootModel No.Maximum W/ft.DBT 300DBF 250CB 250DBCT 750DBCF 500RDBT-PD 300ASHDB 5004. Enclosure sections only with <strong>an</strong>odizedaluminum fronts <strong>an</strong>d (or) <strong>an</strong>odized aluminumoutlet grilles are available on a 12 week shipcycle.5. Color selection must be specified in the lineitem notes of the sales order.6. Unit Lengths*2 ft.3 ft.4 ft.5 ft.6 ft.*C<strong>an</strong>not go beyond 10 ft. including extended enclosure.W/ft.Maximum W/ft.(Single Element Heaters) (Double Element Heaters) V/ph125 282 120/single-phase188 376 208/single-phase250 500 240/single-phase93 438 277/single-phase141 564282 666333 750375 625Contact Waco Product Support for moreinformation on these products (1-888-872-6335)Effective 1/1/06PTAC/UH-46These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.


Electric Unit HeatersEnclosures <strong>an</strong>d FinishesTable PTAC/UH-47-A—Extended EnclosureModel No. lg lbs.230-6080 6” 1.0230-6081 12” 2.0230-6082 18” 3.0230-6083 24” 4.0230-6084 30” 5.0230-6085 36” 6.0230-6086 42” 7.0230-6087 48” 8.0230-6088 54” 9.0230-6089 60” 10.01. Extends the Enclosure lg <strong>an</strong>other 6”, 12”, 18”, 24”, 30”, 36”, 42”, 48”, 54” or 60”.2. Extended Enclosure <strong>an</strong>d Heater furnished as a one piece unit.3. M<strong>an</strong>ufactured with solid metal grilles.4. Maximum over all Heater Length with Extended Enclosure is 15 feet for Models (DBT, DBF <strong>an</strong>d CB), 12 feet for Models(DBCT <strong>an</strong>d RDBT-PD) <strong>an</strong>d 10 feet for Model (ASHDB).Table PTAC/UH-47-B—Bl<strong>an</strong>k Enclosure Sectionslbs.Model No. Dimensions per ft.DBT 6” High x 3½” dp 4.0DBF 6” High x 3½” dp 4.0CB 4½” High x 2 5/8 ” dp 3.0DBCT 7” High x 5” dp 5.0DBCF 7” High x 5” dp 5.0RDBT-PD 5” High x 6” dp 5.0ASHDB 8” High 7.510” High 8.512” High 9.514” High x 5½” dp 10.516” High 11.518” High 12.520” High 13.51. M<strong>an</strong>ufactured with solid metal grille less the electric heating element.2. Available in 1 ft. through 10 ft. lengths in 1 ft. increments.3. C<strong>an</strong> be modified for use with hydronic heating elements for Models DBT, DBF, DBCT, DBCF <strong>an</strong>d ASHDB only.Table PTAC/UH-47-C—Finish SelectionColor Ordering Number .Clear AnodizedFSHP-CLEARBronze AnodizedFSHP-BRONZEBlack AnodizedFSHP-BLACK_ANODIvory, Gray, or Eggshell White FSHBP-E_WHITEBeige Baked Enamel 1FSHBP-BEIGEWhite Baked EnamelFSHBP-WHITEBrown Baked EnamelFSHP-BROWNBlack Baked EnamelFSHP-BLACK1. Baked Enamel Color Finish per Electric Wall Fin Color Selection Chart - FIN-S-3.2. Model ASHDB only c<strong>an</strong>not have <strong>an</strong>odized color finish.Table PTAC/UH-47-D—Finished Back P<strong>an</strong>els - OptionalFinished Back P<strong>an</strong>elOrdering NumberClear Anodized (204R1)FSHP-CLEARBronze Anodized (313R1)FSHP-BRONZEBlack Anodized (313R1)FSHP-BLACK_ANODIvory, Gray, or Eggshell White FSHBP-E_WHITEBeige Baked EnamelFSHBP-BEIGEWhite Baked EnamelFSHBP-WHITEBrown Baked EnamelFSHP-BROWNBlack Baked EnamelFSHP-BLACK1. Finished back p<strong>an</strong>els either painted or <strong>an</strong>odized in the same color as the heater are available for pedestal floor mountedheaters to be installed in front of windows <strong>an</strong>d in lobbies.These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)PTAC/UH-47 Effective 1/1/06


Electric Unit HeatersElectric Wall Fin AccessoriesTable PTAC/UH-48-A—¼” Wire Mesh - Optional1/4” Wire Mesh1. Factory installed under grille on enclosure or Bl<strong>an</strong>k Enclosure Sections <strong>an</strong>d Extended Enclosure Sections with opengrilles.Table PTAC/UH-48-B—Pedestal Brackets - OptionalOrdering No.230-6020 ASB PD Pedestals1. For floor mounting of all Model Heaters. Must be ordered separately.2. Pedestal brackets are available for floor mounting in lobbies <strong>an</strong>d in front of windows for all models except ASHDB 10”,12”, 14”, 18” <strong>an</strong>d 20” high heaters. Factory installed to the bottom of the unit for field furnished power wiring to be runthrough the center of the pedestal into the bottom of the units junction box for connection to the heater. The knockouts thatare provided in the side <strong>an</strong>d rear of each heaters junction box <strong>an</strong>d the back p<strong>an</strong>el mounting holes for wall mounting ofunits are not furnished when pedestals are ordered. 2’ to 6’ heaters require two pedestals, 6’ to 8’ heaters require threepedestals, 9’ <strong>an</strong>d 10’ heaters require four pedestals.Table PTAC/UH-48-C—Factory Built-In Controls - OptionalOrdering No. Model No. Description230-6000 ITS Single Pole Thermostat 20A 120-277 Vac 1230-6002 ITD Double Pole Thermostat 20A 120-277 Vac 1230-6005 IDS Double Pole Disconnect Switch 20A 120-277 Vac 2230-6010 ATR Tr<strong>an</strong>sformer Relay single pole 25A 120-277 Vac 3230-6012 PR Power Relay Contactor 208/24, 208/208 18 amp 4, 5230-6014 PR Power Relay Contactor 240/24 18 amp 4, 5230-6016 PR Power Relay Contactor 277/24, 277/277 18 amp 4, 51. Factory mounted <strong>an</strong>d wired in left h<strong>an</strong>d junction box, adjustable thru discharge grille.2. Factory mounted <strong>an</strong>d wired in left h<strong>an</strong>d junction box, adjustable thru discharge grille.3. Rated 25 Amp 120-277 VAC contacts rated up thru 277V <strong>an</strong>d must be specified. Coils are 24V <strong>an</strong>d 120V <strong>an</strong>d must be specified. Requires 6” or 12” Control Sections for mounting whichwill lengthen the heater dimensions. 12” Extended Enclosures must be used.4. Requires 6” or 12” Control Sections for mounting which will lengthen the heater dimensions. 12” Extended Enclosures must be used.5. St<strong>an</strong>dard Contactor with 18 Amp contacts <strong>an</strong>d coil voltage of 24V or same as primary voltage of the heater as specified.TTable PTAC/UH-48-D—Control SectionsOrdering No. Model No. Description230-6030 CS6 6” Control Section 1230-6033 CS12 12” Control Section 21. For factory mounting of 1 or 2 controls. Right or left side mounting available with right side being st<strong>an</strong>dard. Requires 12” Extended Enclosure for installation. Control Sections must be fieldwired to the heater.2. For factory mounting of 1, 2 or 3 controls. Right or left side mounting available with right side being st<strong>an</strong>dard. Requires 12” Extended Enclosure for installation. Control Sections must befield wired to the heater.Table PTAC/UH-48-E—Inside CornersModel No.Ordering No.DBT-ICDBF-IC 230-6040CB-ICDBCT-IC 230-6044DBCF-ICRDBT-PD-IC 230-6046ASHDB-IC 8”-20” 230-60481. Inside Corners 90 - 180° furnished as st<strong>an</strong>dard.Table PTAC/UH-48-F—Outside CornersModel No.Ordering No.DBT-OCDBF-OC 230-6050CB-OCDBCT-OC 230-6054DBCF-OCRDBT-PD-OC 230-6056ASHDB-OC 8”-20” 230-60581. Outside Corners 180 - 270° furnished as st<strong>an</strong>dard.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)Effective 1/1/06PTAC/UH-48These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.


Electric Unit HeatersElectric Wall Fin AccessoriesTable PTAC/UH-49-A—LH <strong>an</strong>d RH End CapsModel No.Ordering No.DBT-ECDBF-EC LH - 230-6051CB-EC RH - 230-6055DBCT-ECDBCF-ECASHDB-EC LH - 230-6053RH - 230-6059RDBT-ECLH-PDIECRDBT-ELRH-PDIEC1. Specify Left or Right h<strong>an</strong>d.2. To cap off each end of the heater for a finished look.Table PTAC/UH-49-B—2” Wall TrimsModel No.Ordering No.DBT-WT_DBF-WT_ 230-6062CB-WT_DBCT-WT_ 230-6063DBCF-WT_ASHDB-WT_ 230-60651. Extends the end of the heater to the wall or column.Table PTAC/UH-49-C—6” Wall TrimsModel No.Ordering No.DBT-WT_DBF-WT_ 230-6061CB-WT_DBCT-WT_ 230-6067DBCF-WT_ASHDB-WT_ 230-60681. Extends the end of the heater to the wall or column.Table PTAC/UH-49-D—1½” Splice PlateModel No.Ordering No.DBT-SPDBF-SP 230-6060CB-SPDBCT-SP 230-6064DBCF-SPASHDB-SP 230-60661. Conceals gap between two heaters or bl<strong>an</strong>k sections.Table PTAC/UH-49-E—Accessories for Mounting Hydronic Heating ElementsItemOrdering No.Rod H<strong>an</strong>gers 230-6070Slide Cradle Brackets 230-60716” Valve Compartment Bl<strong>an</strong>k Sections 230-607212” Valve Compartment Bl<strong>an</strong>k Sections 230-60741. Order qty. 2 Rod H<strong>an</strong>gers or Slide Cradle Brackets for 2' - 5' lengths, qty. 3 for 6' - 8' lengths <strong>an</strong>d qty. 4 for 9' - 10' lengths.Table PTAC/UH-49-F—Wall Mounted Controls — OptionalModel No. Order No. DescriptionTW241 230-006 SPST Wall Mounted Line Voltage Thermostat, 40-90°F, 250 VA 2TW242 230-007 DPST Wall Mounted Line Voltage Thermostat, 40-90°F, 250 VA 2MB-120 230-009 Wall Mounted Low Voltage Thermostat, 50-90°F, 24VA6281 1 233-370 Remote Mounted Thermal Relay with Built-In Line Voltage/24VTr<strong>an</strong>sformer. 120, 208, 240 or 277V SPST 25 Amp1. Specify voltage on the sales order.2. Electrical rating <strong>an</strong>d W — 120V - 2600W, 208V - 4500W, 240V - 5200W <strong>an</strong>d 277V - 4900W.These items are not available to all distribution ch<strong>an</strong>nels.Please contact your distributor or local sales office for moreinformation.Contact Waco Product Support for moreinformation on these products (1-888-872-6335)PTAC/UH-49 Effective 1/1/06


PROMO STAMPIF APPLICABLEExtended Warr<strong>an</strong>ty Labor OptionsLabor Options provide more flexibility forthe dealer <strong>an</strong>d are selected at the time ofsale. These options determine how longa dealer has to guar<strong>an</strong>tee his labor, <strong>an</strong>destablish the set of “Servicer Guideline”rates that c<strong>an</strong> be used when makingclaims. The options are as follows:Labor Option #1:<strong>Tr<strong>an</strong>e</strong>’s Optional Extended Warr<strong>an</strong>ty isresponsible for labor beginning theninety-first (91st) day from the dateof installation or the date activated,whichever is later. The dealer is responsiblefor the labor through the first ninety(90) days.Labor Option #2:<strong>Tr<strong>an</strong>e</strong>’s Optional Extended Warr<strong>an</strong>ty isresponsible for labor beginning one (1)year from the date of installation. Thedealer is responsible for the laborthrough the first (1st) year. Labor Option#2 is not available on equipment over 9months old or on "Parts Only" OptionalExtended Warr<strong>an</strong>ties.Labor Option #3:<strong>Tr<strong>an</strong>e</strong>’s Optional Extended Warr<strong>an</strong>ty isresponsible for labor beginning theninety-first (91st) day from the date ofinstallation or the date activated,whichever is later. The dealer is responsiblefor labor through the first ninety(90) days.Coverage for Labor Option #3 will costmore th<strong>an</strong> the other two options. If itis chosen, the <strong>Tr<strong>an</strong>e</strong> Optional ExtendedWarr<strong>an</strong>ty Agreement will automaticallybe assigned the letter “X” to the end ofthe model number. (Example:TAYWAR0004 that contains LaborOption #3 will become TAYWAR0004X).To determine the exact cost of <strong>an</strong> <strong>Tr<strong>an</strong>e</strong>Optional Extended Warr<strong>an</strong>ty thatcontains Labor Option #3, refer to theprice book <strong>an</strong>d select the model numberthat contains the letter “X”at the end of the model number. It is notnecessary to indicate the“X” in the model number whencompleting <strong>an</strong> application.The “Servicer Guideline Rates” forlabor options #1, #2, <strong>an</strong>d #3 areused when submitted claims <strong>an</strong>dare noted on page WA-2 <strong>an</strong>d WA-3.UNITARYPRODUCTS GROUPDealer/SellerDealer/Seller #Name ____________________________________Address __________________________________City, State, Zip ____________________________Telephone # ( ______ ) _____________________Warr<strong>an</strong>ty Model # T A Y W A RServicer (if other th<strong>an</strong> Dealer/Seller)Servicer #Name ____________________________________Address __________________________________City, State, Zip ____________________________Telephone # ( ______ ) _____________________Completed by Distributor OnlyBill to #Name ______________________________________________Approved By _______________________________________Purchasers P.O. # ____________________________________(If Desired)* Not used on somewarr<strong>an</strong>ty model numbers.Servicer Labor Option: 1 2 3 (Circle One)Is this warr<strong>an</strong>ty a renewal of <strong>an</strong> existing Extended Warr<strong>an</strong>ty? Yes NoIf yes, what is the agreement number of the old warr<strong>an</strong>ty .Product Application: ■ <strong>Residential</strong> ■ CommercialEquipment Covered: ■ System ■ Condensing Unit ■ Furnace/Air H<strong>an</strong>dler ■ Compressor Only ■ Other ______________Length of Coverage: ■ 1 Year ■ 5 Years ■ 10 Years ■ 15 Years ■ 20 YearsType of Coverage: ■ Parts Only ■ Labor Only ■ Both Parts <strong>an</strong>d LaborNote: Not all combinations of above are available. The warr<strong>an</strong>ty model number listed above must agree with selections.EQUIPMENT OWNER: (Mailing Address)EQUIPMENT LOCATION: (If Different)NameAddressFor Extended Warr<strong>an</strong>ty Dept. Use OnlyAgreement No. __________________________________Rec’d. Date: __________________________________EXTENDED WARRANTY APPLICATIONCity State Zip (Required) City State Zip (Required)( )TelephoneEQUIPMENT Note: Use separate applications for each required agreement.COVERED MODEL # – use 1st 11 digits SERIAL # Date Equipment Installed ___________________Required___________________ _________________________ _____________________________________________ _________________________ __________________________ Date Warr<strong>an</strong>ty Sold ___________________By Dealer___________________ _________________________ _____________________________________________ _________________________ __________________________ Warr<strong>an</strong>ty Sales Price $ __________________If the Equipment Covered is a Compressor Only – What is the Condensing Unit Model # ___________________________________What is the Condensing Unit Serial # ___________________________________This Document is <strong>an</strong> Application Only. The Extended Warr<strong>an</strong>ty will become effective when accepted byThe <strong>Tr<strong>an</strong>e</strong> Comp<strong>an</strong>y. The <strong>Tr<strong>an</strong>e</strong> Comp<strong>an</strong>y will notify the Equipment Owner by sending the Extended Warr<strong>an</strong>tyAgreement that provides coverage for the Extended Warr<strong>an</strong>ty Model listed above. If you do not receive aconfirming agreement from <strong>Tr<strong>an</strong>e</strong> within 45 days, please call 800-554-6413.As the Equipment Owner, I acknowledge that I haveread <strong>an</strong>d underst<strong>an</strong>d the “Terms <strong>an</strong>d Conditions” as wellDealer/Seller’s Signature*Date as the type of coverage <strong>an</strong>d length of coverage of the<strong>Tr<strong>an</strong>e</strong> Extended Warr<strong>an</strong>ty for which I have applied.DEALER INSTRUCTIONS: Send To Your Distributor For Processing.Equipment Owner’s SignatureDate* Dealer/Seller’s signature indicates equipment over 9 months old has been inspected <strong>an</strong>d is in good working condition.Inspection not required if equipment is less th<strong>an</strong> 9 months old or if this is a renewal of <strong>an</strong> existing extended warr<strong>an</strong>ty.Pub. No. 26-1021-06 (12/00)or latest versionNameAddressLabor options are chosen at the time <strong>an</strong> application is completed using the three(3) selection blocks on the application form (see above). The dealer simply marksthe option chosen. When the application is activated, that agreement will always beassociated with that Labor Option. If no option is chosen, then option #1 willautomatically be selected.Refer to the <strong>Tr<strong>an</strong>e</strong> Optional Extended Warr<strong>an</strong>ty H<strong>an</strong>dbook for additional information(Pub. No. 26-1019).Great care has been taken to ensure the accuracy of the information in the Extended Warr<strong>an</strong>tysection of the <strong>Residential</strong> <strong>an</strong>d Light Commercial Products H<strong>an</strong>dbook; however, the information inthe <strong>Tr<strong>an</strong>e</strong> Optional Extended Warr<strong>an</strong>ty h<strong>an</strong>dbook supersedes all information contained herein.WA-1 Effective 1/1/06


<strong>Tr<strong>an</strong>e</strong> Optional Extended Warr<strong>an</strong>ty“St<strong>an</strong>dard Servicer Guidelines”These guidelines should be used when submitting claims on “<strong>Tr<strong>an</strong>e</strong> Extended Warr<strong>an</strong>ty” agreements - St<strong>an</strong>dard or Labor Option #1.1. ALLOWABLE LABOR RATES ———————— Dealer’s st<strong>an</strong>dard hourly rate.2. PARTS MARK UP ALLOWANCE (Used for out-of-warr<strong>an</strong>ty parts)$0.01 - 4.99 = Dealer Cost + $5.00$5.00 - 24.99 = Dealer Cost x 2.0$25.00 - 49.99 = Dealer Cost x 1.7$50.00 - 149.99 = Dealer Cost x 1.6$150.00 - 499.99 = Dealer Cost x 1.5$500.00 - up = Dealer Cost x 1.4Refriger<strong>an</strong>t = Dealer Cost x 2.0IN-WARRANTY PARTS MARK UP ALLOWANCE (Used for in-Warr<strong>an</strong>ty Parts, years 2-5 when equipment has 5-year parts M<strong>an</strong>ufacturer’s Limited Warr<strong>an</strong>ty. Does not apply tocompressor, outdoor coil, or heat exch<strong>an</strong>ger. If a non-<strong>Tr<strong>an</strong>e</strong> part is purchased during the M<strong>an</strong>ufacturer’s Limited Warr<strong>an</strong>ty period, dealer will be reimbursed cost of part only,maximum $10.00)Labor Option #1$0.01 - 4.99 = Dealer’s Normal Purchase Price, $5.00$5.00 - 24.99 = Dealer’s Normal Purchase Price x 1.0$25.00 - 49.99 = Dealer’s Normal Purchase Price x 0.7$50.00 - 149.99 = Dealer’s Normal Purchase Price x 0.6$150.00 - 499.99 = Dealer’s Normal Purchase Price x 0.5$500.00 - up = Dealer’s Normal Purchase Price x 0.43. REPAIR/REPLACE TIME — The hours provided below constitute the maximum number of hours that may be claimed. If your actual repair or replacement time is lessth<strong>an</strong> the amounts specified below, or as described in this paragrah, your actual time must be reported. For multiple component replacements in the same unit, eachadditional component may receive a maximum of 0.5 hours. For <strong>an</strong>y component not listed, it may receive a maximum of 0.5 hours. If your actual repair or replacement time isgreater th<strong>an</strong> the amounts specified below, or as described in this paragraph, <strong>an</strong>d you believe that additional time is justified, please explain the circumst<strong>an</strong>ces of the repair orreplacement in writing.Max Hours AllowedReplacement or Repaired Item 1-5 Tons 6 1/4 - 25 TonsRefriger<strong>an</strong>t Circuit2Refriger<strong>an</strong>t recovery (only if required) .................................................................... 1.0 2.0Compressor replacement3 .................................................................................... 4.0 6.0Condenser coil replacement ................................................................................... 4.0 6.0Evaporator coil replacement ................................................................................... 4.5 6.0Exp<strong>an</strong>sion valve replacement ................................................................................ 3.0 4.0Switch over valve replacement ............................................................................... 3.5 4.5Check valve replacement or service valve ............................................................. 2.0 3.0Drier replacement ................................................................................................... 1.0 1.0Schrader core ......................................................................................................... 0.5 0.5Tighten valves (caps, cores, rotolocks) .................................................................. 0.5 0.5Repairable leak in fitting, etc. (Brazing required,explain work done) ......................... 2.0 3.0Electrical ControlsAny component replacement .................................................................................. 0.5 0.5Hard start kit ........................................................................................................... 0.5 —Thermostat (Indoor) ................................................................................................ 1.0 1.0Thermostat (Outdoor) ............................................................................................. 0.5 0.5Cr<strong>an</strong>kcase heater replacement .............................................................................. 0.5 0.5Condenser F<strong>an</strong> AssembliesF<strong>an</strong> blade replacement ........................................................................................... 0.5 0.5Motor replacement (includes f<strong>an</strong> blade, capacitor) ................................................ 1.5 1.5Evaporator F<strong>an</strong> AssemblyBlower wheel replacement ..................................................................................... 1.0 1.0Motor replacement (includes blower wheel, capacitor) .......................................... 1.5 1.5Replace module (includes motor) ........................................................................... 1.0 1.0Bearing replacement - each ................................................................................... 0.5 0.5Sheaves replacement - each (includes belt) .......................................................... 0.5 0.5Belt replacement ..................................................................................................... 0.5 0.5Drain p<strong>an</strong> replacement ........................................................................................... 2.0 2.0Heating SectionAny control replacement (ignitor, sensor, ignition control, etc.) ............................. 0.5 0.5Heating element replacement ................................................................................ 1.0 1.0Combustion blower replacement ............................................................................ 1.0 1.0Gas valve replacement ........................................................................................... 1.0 1.0Heat exch<strong>an</strong>ger replacement ................................................................................. 4.0 6.0Burners ................................................................................................................... 1.0 1.0Economizer SectionAny control replacement ......................................................................................... 0.5 0.5Actuator replacement ............................................................................................. 1.0 1.0Misc. SectionSolve noise complaint7 ......................................................................................... 0.5 0.5Diagnostic Charge1 ............................................................................................... 0.5 0.5Multiple Components .............................................................................................. 0.5 0.5NOTES:1 Diagnostic calls will be paid only on covered repairs. (Not paid on mainten<strong>an</strong>ce or dirty sock)2 All times allowed requiring entry or repair to refriger<strong>an</strong>t circuit includes evacuation, recharge <strong>an</strong>d drier ch<strong>an</strong>ge.3 All times allowed for compressor replacement includes drier ch<strong>an</strong>ge, cle<strong>an</strong>up, evacuation <strong>an</strong>d recharge.4 Cr<strong>an</strong>e allow<strong>an</strong>ce up to $150 or 2 hrs. at a Dealer’s registered rate in lieu of cr<strong>an</strong>e charge is allowed on systems applied in a commercial application or if the equipment is 4tons or greater. (Not allowed on parts only warr<strong>an</strong>ty.)5 Sales tax, if applicable, will be reimbursed to the dealer.6 All times not shown for specific tasks - Call 1-800-554-6413.7 Noise complaint paid only when noise due to internal component failure or malfunction. Maximum time allowed is 0.5 hrs. plus the time allowed for the componentreplacement/repair. Explain fully.8 Pay only one (1) m<strong>an</strong> per job.9 All invoices must be received within sixty (60) days of the repair.TRAVEL TIME: (Flat Rate Dealers c<strong>an</strong>not charge Travel Time)24 miles or less, one way - add 1/2 hour based on your established labor rate.25 miles or greater, one way - add 1 hour based on your established labor rate.Only one (1) trip charge paid per service call.ALL CLAIMS RELATED DECISIONS MADE BY AMERICAN STANDARD WARRANTY COMPANY ARE FINAL.Effective 1/1/06WA-2Great care has been taken to ensure the accuracy ofthe information in the Extended Warr<strong>an</strong>ty section ofthe <strong>Residential</strong> <strong>an</strong>d Light Commercial ProductsH<strong>an</strong>dbook; however, the information in the <strong>Tr<strong>an</strong>e</strong>Optional Extended Warr<strong>an</strong>ty h<strong>an</strong>dbook supersedesall information contained herein.


<strong>Tr<strong>an</strong>e</strong> Optional Extended Warr<strong>an</strong>ty“Exp<strong>an</strong>ded Servicer Guidelines”These guidelines should be used when submitting claims on “<strong>Tr<strong>an</strong>e</strong> Optional Extended Warr<strong>an</strong>ty” Agreements - Labor Option #2 & #3.1. ALLOWABLE LABOR RATES ———————— Dealer’s st<strong>an</strong>dard hourly rate.2. PARTS MARK UP ALLOWANCE (Used for out-of-warr<strong>an</strong>ty parts)$0.01 - 4.99 = Dealer Cost + $7.50$5.00 - 24.99 = Dealer Cost x 2.5$25.00 - 49.99 = Dealer Cost x 2.1$50.00 - 149.99 = Dealer Cost x 1.9$150.00 - 499.99 = Dealer Cost x 1.7$500.00 - up = Dealer Cost x 1.5Refriger<strong>an</strong>t = Dealer Cost x 2.0IN-WARRANTY PARTS MARK UP ALLOWANCE (Used for in-Warr<strong>an</strong>ty Parts, years 2-5 when equipment has 5 year parts M<strong>an</strong>ufacturer’s Limited Warr<strong>an</strong>ty. Does not apply tocompressor, outdoor coil, or heat exch<strong>an</strong>ger. If a non-<strong>Tr<strong>an</strong>e</strong> part is purchased during the M<strong>an</strong>ufacturer’s Limited Warr<strong>an</strong>ty period, dealer will be reimbursed cost of part only,maximum $10.00)Labor Option #2 <strong>an</strong>d #3$0.01 - 4.99 = Dealer’s Normal Purchase Price, $7.50$5.00 - 24.99 = Dealer’s Normal Purchase Price x 1.5$25.00 - 49.99 = Dealer’s Normal Purchase Price x 1.1$50.00 - 149.99 = Dealer’s Normal Purchase Price x 0.9$150.00 - 499.99 = Dealer’s Normal Purchase Price x 0.7$500.00 - up = Dealer’s Normal Purchase Price x 0.53. REPAIR/REPLACE TIME — The hours provided below constitute the maximum number of hours that may be claimed. If your actual repair or replacement time is lessth<strong>an</strong> the amounts specified below, or as described in this paragrah, your actual time must be reported. For multiple component replacements in the same unit, eachadditional component may receive a maximum of 0.5 hours. For <strong>an</strong>y component not listed, it may receive a maximum of 0.5 hours. If your actual repair or replacement time isgreater th<strong>an</strong> the amounts specified below, or as described in this paragraph, <strong>an</strong>d you believe that additional time is justified, please explain the circumst<strong>an</strong>ces of the repair orreplacement in writing.Max Hours AllowedReplacement or Repaired Item 1-5 Tons 6 1/4 - 25 TonsRefriger<strong>an</strong>t Circuit2Refriger<strong>an</strong>t recovery (only if required) ........................................................................... 1.0 2.0Compressor replacement3 ........................................................................................... 4.0 6.0Condenser coil replacement .......................................................................................... 4.0 6.0Evaporator coil replacement .......................................................................................... 4.5 6.0Exp<strong>an</strong>sion valve replacement ........................................................................................ 3.0 4.0Switch over valve replacement ...................................................................................... 3.5 4.5Check valve replacement or service valve ..................................................................... 2.0 3.0Drier replacement .......................................................................................................... 1.0 1.0Schrader core ................................................................................................................ 0.5 0.5Tighten valves (caps, cores, rotolocks) .......................................................................... 0.5 0.5Repairable leak in fitting, etc. (brazing required explain work done) ............................. 2.0 3.0Electrical ControlsAny component replacement ......................................................................................... 0.5 0.5Hard start kit ................................................................................................................... 0.5 —Thermostat (Indoor) ....................................................................................................... 1.0 1.0Thermostat (Outdoor) .................................................................................................... 0.5 0.5Cr<strong>an</strong>kcase heater replacement ...................................................................................... 0.5 0.5Condenser F<strong>an</strong> AssembliesF<strong>an</strong> blade replacement .................................................................................................. 0.5 0.5Motor replacement (includes f<strong>an</strong> blade capacitor) ......................................................... 1.5 1.5Evaporator F<strong>an</strong> AssemblyBlower wheel replacement ............................................................................................. 1.0 1.0Motor replacement (includes blower wheel, capacitor) .................................................. 1.5 1.5Module replacement (includes motor) ............................................................................ 1.0 1.0Bearing replacement - each ........................................................................................... 0.5 0.5Sheaves replacement - each (includes belt) .................................................................. 0.5 0.5Belt replacement ............................................................................................................ 0.5 0.5Drain p<strong>an</strong> replacement ................................................................................................... 2.0 2.0Heating SectionAny control replacement (ignitor, sensor, ignition control, etc.) .................................... 0.5 0.5Heating element replacement ........................................................................................ 1.0 1.0Combustion blower replacement ................................................................................... 1.0 1.0Gas valve replacement .................................................................................................. 1.0 1.0Heat exch<strong>an</strong>ger replacement ......................................................................................... 4.0 6.0Burners .......................................................................................................................... 1.0 1.0Economizer SectionAny control replacement ................................................................................................ 0.5 0.5Actuator replacement ..................................................................................................... 1.0 1.0Misc. SectionSolve noise complaint7 ................................................................................................ 0.5 0.5Diagnostic Charge1 ...................................................................................................... 0.5 0.5Multiple Components ..................................................................................................... 0.5 0.5Great care has been taken to ensure the accuracy ofthe information in the Extended Warr<strong>an</strong>ty section ofthe <strong>Residential</strong> <strong>an</strong>d Light Commercial ProductsH<strong>an</strong>dbook; however, the information in the <strong>Tr<strong>an</strong>e</strong>Optional Extended Warr<strong>an</strong>ty h<strong>an</strong>dbook supersedesall information contained herein.NOTES: 1 Diagnostic calls will be paid only on covered repairs. (Not paid on mainten<strong>an</strong>ce or dirty sock)2 All times allowed requiring entry or repair to refriger<strong>an</strong>t circuit includes evacuation, recharge <strong>an</strong>d drier ch<strong>an</strong>ge.3 All times allowed for compressor replacement includes drier ch<strong>an</strong>ge, cle<strong>an</strong>up, evacuation <strong>an</strong>d recharge.4 Cr<strong>an</strong>e allow<strong>an</strong>ce up to $150 or 2 hrs. at a Dealer’s registered rate in lieu of cr<strong>an</strong>e charge is allowed on systems applied in a commercial application or if theequipment is 4 tons or greater. (Not allowed on parts only warr<strong>an</strong>ty.)5 Sales tax, if applicable, will be reimbursed to the dealer.6 All times not shown for specific tasks - Call 1-800-554-6413.7 Noise complaint paid only when noise due to internal component failure or malfunction. Maximum time allowed is 0.5 hours plus the timeallowed for the component replacement/repair. Explain fully.8 Pay only one (1) m<strong>an</strong> per job.9 All invoices must be received within sixty (60) days of the repair.TRAVEL TIME (Flat Rate Dealers c<strong>an</strong>not charge Travel Time):Mileage (<strong>an</strong>y dist<strong>an</strong>ce) - add 1 hour based on your established labor rate.Two (2) trip charges are allowed for major component replacement (compressor, outdoor coil, evaporator coil, switch over valve, burners, or heat exch<strong>an</strong>ger).ALL CLAIMS RELATED DECISIONS MADE BY AMERICAN STANDARD WARRANTY COMPANY ARE FINAL.WA-3 Effective 1/1/06


Optional Extended Warr<strong>an</strong>ty BenefitsConsumer BenefitsPeace of Mind• No unexpected out-of-pocket expenses*• Repair/Replace option allows consumer to apply repair cost towardpurchase price of new equipment• Hedge against inflation (parts, labor <strong>an</strong>d refriger<strong>an</strong>t)Assur<strong>an</strong>ce of Commitment• <strong>Tr<strong>an</strong>e</strong> dealer assigned to their agreement has up-to-dateknowledge of equipment <strong>an</strong>d service techniques• Extended Warr<strong>an</strong>ty is tr<strong>an</strong>sferrable to subsequent homeownersshould the original owner sell their home• Cost effective as compared to other Extended Warr<strong>an</strong>ties(i.e., appli<strong>an</strong>ces, consumer electronics, automobiles)Dealer Benefits• Labor Coverage after 90th Day (lower labor reserves)• Extended Warr<strong>an</strong>ty contracts assign selling dealer as servicer ofrecord which potentially “locks in” customer for the life of thewarr<strong>an</strong>ty• Provides “In Warr<strong>an</strong>ty” parts markup (revenue opportunity)• Additional profit opportunity by selling the Extended Warr<strong>an</strong>ty(gross profit becomes close to net profit)• Repair/Replace option allows consumer to apply repair coststoward purchase price of new equipment• Dealer provides more comprehensive coverage which improvescustomer satisfaction with dealer <strong>an</strong>d <strong>Tr<strong>an</strong>e</strong>• Encourages the sale of Mainten<strong>an</strong>ce Agreements• Commercial Product up to 25 tons c<strong>an</strong> be covered up to 10 yearsfor parts <strong>an</strong>d labor• New construction dealer c<strong>an</strong> include Extended Warr<strong>an</strong>ties, capturingcustomers they normally don’t see (if agreement is put in thebuilder’s name, the agreement c<strong>an</strong> be tr<strong>an</strong>sferred to the newhomeowner at no charge)Great care has been taken to ensure the accuracy of the information in the Extended Warr<strong>an</strong>ty section of the <strong>Residential</strong> <strong>an</strong>d LightCommercial Products H<strong>an</strong>dbook; however, the information in the <strong>Tr<strong>an</strong>e</strong> Optional Extended Warr<strong>an</strong>ty h<strong>an</strong>dbook supersedes allinformation contained herein.*Covers labor, refriger<strong>an</strong>t, diagnostic, <strong>an</strong>d parts, subject to product coverage <strong>an</strong>d terms <strong>an</strong>d conditions.Effective 1/1/06WA-4


Optional Extended Warr<strong>an</strong>ty BenefitsExample:Assumptions:• Unit is 4 years old <strong>an</strong>d <strong>an</strong> Evaporator Coil must be replaced• Evaporator Coil is <strong>an</strong> in-warr<strong>an</strong>ty part that would normally cost $500if purchased• Dealer has $70/hr. labor rate (time <strong>an</strong>d material, not flat rate)• 7 lbs. of R410A needed for repair (dealer cost is $11/lb.)Consumer has NoConsumer has 10-Yr. P&L, Lbr. Opt. 3 Extended Warr<strong>an</strong>ty DifferenceEW Pays DealerConsumer Pays DealerLabor Travel (2 hrs.) $ 140.00 $ 140.00 $ -Diagnostic (.5 hrs.) $ 35.00 $ 35.00 $ -Repair (4.5 hrs.) $ 315.00 $ 315.00 $ -Total $ 490.00 $ 490.00 $ -Parts Coil (.5 x normal cost) $ 250.00 $ - (in-warr<strong>an</strong>ty part) $ 250.00R410A(2 x #lbs. x dealer cost) $ 154.00 $ 154.00 $ -Total $ 894.00 $ 644.00 $ 250.00Profit on Parts $ 327.00 $ 77.00 $ 250.00• In the above example, even with a 10-year Limited Warr<strong>an</strong>ty on parts, the consumer still paid $644 for acoil replacement, <strong>an</strong>d you made only $77 in profit on parts. With the Extended Warr<strong>an</strong>ty, the consumerpays nothing for the repair <strong>an</strong>d you made <strong>an</strong> additional $250 in profit on partsSelling Story:• The Extended Warr<strong>an</strong>ty should be offered at time of sale (c<strong>an</strong> beincluded with fin<strong>an</strong>cing)• Use the Extended Warr<strong>an</strong>ty Sales Brochure, Pub. No. 26-1016 <strong>an</strong>d theconsumer benefits on the reverse side• Point out that Limited Warr<strong>an</strong>ty does not cover refriger<strong>an</strong>t or labor• If the Extended Warr<strong>an</strong>ty is “included” in the total proposal, it is much easierto sell• If you are in a “regulated” state, you must provide the actual purchase price(not to be less th<strong>an</strong> your actual cost) on the Extended Warr<strong>an</strong>ty Application.This amount will appear on the consumer’s agreement (see your ExtendedWarr<strong>an</strong>ty H<strong>an</strong>dbook for more information on selling Extended Warr<strong>an</strong>ties in“regulated” states)Great care has been taken to ensure the accuracy of the information in the Extended Warr<strong>an</strong>ty section ofthe <strong>Residential</strong> <strong>an</strong>d Light Commercial Products H<strong>an</strong>dbook; however, the information in the <strong>Tr<strong>an</strong>e</strong> OptionalExtended Warr<strong>an</strong>ty h<strong>an</strong>dbook supersedes all information contained herein.WA-5 Effective 1/1/06


Roof CurbsBAYCURB050A FULL PERIMETER ROOF MOUNTING CURB OUTLINE018 through 036Full Perimeter BAYCURB050A4TCC3018-036A4TCX3018-036A2/4WCC3018-036A2/4WCX3018-036A2/4YCC3018-036A2/4YCX3018-036AFull Perimeter BAYCURB051A4TCC3042-060A4TCX3042-060A2/4WCC3042-060A2/4WCX3042-060A2/4YCC3042-060A2/4YCX3042-060ABAYCURB051A FULL PERIMETER ROOF MOUNTING CURB OUTLINE042 through 060For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.AC/IN-1 Effective 1/1/06


Roofcurb AdaptorsBAYADAP050A CURB ADAPTOR FOR ***018-36A TO EXISTING BAYCURB030 OR BAYCURB038*All 15 digit model numbers starting with 2 or 4 <strong>an</strong>dYCC, YCX, TCC, TCX, WCC <strong>an</strong>d WCX.EXISTING NEW UNIT USECURB 2/4TC/WC/YC****A BAYADAP0**ABAYCURB030,38A 018-036 50BAYCURB030,38A 042-060 52BAYCURB033A 018-036 51BAYCURB033A 042-060 53BAYCURB034A 042-060 54Effective 1/1/06AC/IN-2For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Roofcurb AdaptorsBAYADAP051A CURB ADAPTOR FOR ***018-36A TO EXISTING BAYCURB033*All 15 digit model numbers starting with 2 or 4 <strong>an</strong>dYCC, YCX, TCC, TCX, WCC <strong>an</strong>d WCX.EXISTING NEW UNIT USECURB 2/4TC/WC/YC****A BAYADAP0**ABAYCURB030,38A 018-036 50BAYCURB030,38A 042-060 52BAYCURB033A 018-036 51BAYCURB033A 042-060 53BAYCURB034A 042-060 54For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.AC/IN-3 Effective 1/1/06


Roofcurb AdaptorsBAYADAP052A CURB ADAPTOR FOR *****042-60A TO EXISTING BAYCURB030 OR BAYCURB038*All 15 digit model numbers starting with 2 or 4 <strong>an</strong>dYCC, YCX, TCC, TCX, WCC <strong>an</strong>d WCX.EXISTING NEW UNIT USECURB 2/4TC/WC/YC****A BAYADAP0**ABAYCURB030,38A 018-036 50BAYCURB030,38A 042-060 52BAYCURB033A 018-036 51BAYCURB033A 042-060 53BAYCURB034A 042-060 54Effective 1/1/06AC/IN-4For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Roofcurb AdaptorsBAYADAP053A CURB ADAPTOR FOR *****042-60A TO EXISTING BAYCURB030 OR BAYCURB03356 1/8"53 1/8" I.D.19 1/2" I.D. 28 7/8" I.D.10"Weight in Lbs.EXISTINGCURB61 21/32"41 7/8"56 1/8"ShippingWeightOperatingWeight155110SAROOFVIEW “A”-”A”RAEXISTING CURBBAYCURB03341 7/8"38 7/8" I.D.20" I.D.“A”57 21/32"31"“B”EXISTINGCURB35"“A”“B”ROOFVIEW “B”-”B”*All 15CCdigitCmodelCCnumbersCstartingCCwithC2 or 4 <strong>an</strong>dYCC, YCX, TCC, TCX, WCC <strong>an</strong>d WCX.EXISTING NEW UNIT USECURB 2/4TC/WC/YC****A BAYADAP0**ABAYCURB030,38A 018-036 50BAYCURB030,38A 042-060 52BAYCURB033A 018-036 51BAYCURB033A 042-060 53BAYCURB034A 042-060 54For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.AC/IN-5 Effective 1/1/06


Roofcurb AdaptorsBAYADAP054A CURB ADAPTOR FOR *****042-60A TO EXISTING BAYCURB034*All 15 digit model numbers starting with 2 or 4 <strong>an</strong>dYCC, YCX, TCC, TCX, WCC <strong>an</strong>d WCX.EXISTING NEW UNIT USECURB 2/4TC/WC/YC****A BAYADAP0**ABAYCURB030,38A 018-036 50BAYCURB030,38A 042-060 52BAYCURB033A 018-036 51BAYCURB033A 042-060 53BAYCURB034A 042-060 54Effective 1/1/06AC/IN-6For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Impack Roof CurbsBAYCURB030A UNIVERSAL ROOF MOUNTING CURB OUTLINEUniversal curb w/adaptations, fits all Impack modelsFull Perimeter BAYCURB030AFull Perimeter BAYCURB038ATCC018-042 WCC018-042 YCC018-036M TCC018-042 WCC018-042 YCC018-036MTCP024-030 WCX024-030 YCP024-36M TCP024-030 WCX024-030 YCP024-36MTCX024-030 WCY024-030 YCX024-036M TCX024-030 WCY024-030 YCX024-036MTCY024-030TCY024-030BAYCURB038A UNIVERSAL ROOF MOUNTING CURB OUTLINEInsul.DeckFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.Universal curb w/adaptations,fits all Impack models with insulated deck p<strong>an</strong>sFrom Dwg. 21C662034 Rev. 2AC/IN-7 Effective 1/1/06


Impack Roof CurbsBAYCURB033A ROOF MOUNTING CURB OUTLINEFull perimeter fit curb for Impack models with insulated deck p<strong>an</strong>Full Perimeter BAYCURB033AFull Perimeter BAYCURB034ATCP036-042F WCP036 YCC036H,042 TCC048-060 WCC048-060 YCC048H-060048MTCX036-042G WCX036-042G YCP036H-042 TCP048-060 WCP048-060 YCP048-060TCY036-042G WCY036-042G YCX036H-042 TCX048-060 WCX048-060G YCX048-060TCY048-060G WCZ036 YCY024-042 WCY048-060G YCY048-060YCZ036F WCZ060F YCZ050, 060FBAYCURB034A ROOF MOUNTING CURB OUTLINESUPPLY /RETURN AIR DUCT OPENINGSFull perimeter fit curb for Impack models with insulated deck p<strong>an</strong>Effective 1/1/06AC/IN-8From Dwg. 21C662034 Rev. 2For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Thermal Exp<strong>an</strong>sion ValvesExp<strong>an</strong>sion Valve TXVCooling/Heat Pump KitGeneral InformationThis Thermostatic Exp<strong>an</strong>sion Valve Kit maybe used on <strong>an</strong>y indoor air h<strong>an</strong>dler or coil thatis equipped with a current thermostaticexp<strong>an</strong>sion valve with <strong>an</strong> internal check valve<strong>an</strong>d mech<strong>an</strong>ical fittings This kit c<strong>an</strong> be usedon split system heat pumps <strong>an</strong>d air conditioningsystems.Thermostatic Exp<strong>an</strong>sion Valve Kits c<strong>an</strong> befield installed to fit a variety of sizes <strong>an</strong>dcombinations of air h<strong>an</strong>dlers or coils <strong>an</strong>doutdoor units to optimize perform<strong>an</strong>ce.This TXV kit will normally be used when adifferent refriger<strong>an</strong>t is going to be used in theair h<strong>an</strong>dler or coil th<strong>an</strong> what is indicated onthe unit name plate. The TXV type must alwaysmatch the refriger<strong>an</strong>t type used in theoutdoor unit.Kit IdentificationThe first character in the kit model numberindicates the type of refriger<strong>an</strong>t that thevalve c<strong>an</strong> be used with. Example a2AYTXVH3D1830A is <strong>an</strong> R-22 valve.The “3” in the eighth digit in the modelnumber identifies the valve as a non-bleedTXV. When this TXV kit is installed with <strong>an</strong>outdoor unit that contains a reciprocatingcompressor, the outdoor unit must beequipped with a hard start kit if not factoryinstalled. If the outdoor unit contains a scrollcompressor, the installation of a hard startkit may be required.InspectionCheck carefully for <strong>an</strong>y shipping damage.Any such damage must be reported <strong>an</strong>dclaims made against the tr<strong>an</strong>sportationcomp<strong>an</strong>y immediately. Any missing partsshould be reported to your supplier at once<strong>an</strong>d replaced with authorized parts only.Table AC/IN-9-A Cooling/ Heat Pump Non-Bleed TXV Kits- Dual Direction FlowR-410 R-22 Used WithModel Number Model Numbers 13 SEER Coils4AYTXVH3D1831A 2AYTXVH3C1818A 2/4TXC,CXC,CXA -0184AYTXVH3D1831A 2AYTXVH3C2425A 2/4TXC,CXC,CXA -0244AYTXVH3D1831A 2AYTXVH3C2425A 2/4TXC,CXC,CXA -0254AYTXVH3D1831A 2AYTXVH3C3031A 2/4TXC,CXC,CXA -0304AYTXVH3D1831A 2AYTXVH3C3031A 2/4TXC,CXC,CXA -0314AYTXVH3D3343A 2AYTXVH3C3337A 2/4TXC,CXC,CXA -0364AYTXVH3D3343A 2AYTXVH3C3337A 2/4TXC,CXC,CXA -0374AYTXVH3D3343A 2AYTXVH3C4243A 2/4TXC,CXC,CXA -0424AYTXVH3D3343A 2AYTXVH3C4243A 2/4TXC,CXC,CXA -0434AYTXVH3D4863A 2AYTXVH3C4850A 2/4TXC,CXC,CXA -0484AYTXVH3D4863A 2AYTXVH3C4850A 2/4TXC,CXC,CXA -0494AYTXVH3D4863A 2AYTXVH3C4850A 2/4TXC,CXC,CXA -0504AYTXVH3D4863A 2AYTXVH3C5463A 2/4TXC,CXC,CXA -0604AYTXVH3D4863A 2AYTXVH3C5463A 2/4TXC,CXC,CXA -061Table AC/IN-9-B Cooling/ Heat Pump Non-Bleed TXV Kits- Dual Direction FlowR-410 R-22 Used WithModel Number Model Number Horizontal Flat Coils4AYTXVH3D1831A 2AYTXVH3C1818A 2/4TXF -0184AYTXVH3D3343A 2AYTXVH3C3337A 2/4TXF -0334AYTXVH3D3343A 2AYTXVH3C4243A 2/4TXF -0414AYTXVH3D4863A 2AYTXVH3C5463A 2/4TXF -0544AYTXVH3D4863A 2AYTXVH3C5463A 2/4TXF -063Table AC/IN-9-C Cooling/ Heat Pump Non-Bleed TXV Kits- Dual Direction FlowR-410 R-22 Used WithModel Model High EfficiencyNumber Number Aluminum Coils4AYTXVH3B2531A 2AYTXVH3B2531A 2/4TXC -0254AYTXVH3B2531A 2AYTXVH3B2531A 2/4TXC -0314AYTXVH3B3654A 2AYTXVH3B3637A 2/4TXC -0364AYTXVH3B3654A 2AYTXVH3B3637A 2/4TXC -0374AYTXVH3B3654A 2AYTXVH3B5454A 2/4TXC -0544AYTXVH3B6165A 2AYTXVH3B6161A 2/4TXC -0614AYTXVH3B6165A 2AYTXVH3B6565A 2/4TXC -065Table AC/IN-9-D Cooling/ Heat Pump Non-Bleed TXV Kits- Dual Direction FlowR-410 R-22 Used WithNumber Numbers Air H<strong>an</strong>dlers4AYTXVH3D1831A 2AYTXVH3D1830A 2TFB -018-0304AYTXVH3D1831A 2AYTXVH3D1830A 2/4TFE -0254AYTXVH3D1831A 2AYTXVH3D1830A 2/4TEC -018-030— 2AYTXVH3D3636A 2/4TEC -0364AYTXVH3D3642A — 2/4TEC -036-042— 2AYTXVH3D4260A 2/4TEC -042-0604AYTXVH3D4863A — 2/4TEC -048-0604AYTXVH3D1831A 2AYTXVH3D1830A 2TEH -018-030— 2AYTXVH3D3636A 2TEH -0364AYTXVH3D3642A — 2TEH -036-042— 2AYTXVH3D4260A 2TEH -042-0604AYTXVH3D4863A — 2TEH -048-0604AYTXVH3D1831A 2AYTXVH3D1830A 2TGB -018-0364AYTXVH3D3642A — 2TGB -042— 2AYTXVH3D4260A 2TGB -042-0484AYTXVH3D4863A — 2TGB -048For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.AC/IN-9 Effective 1/1/06


Thermal Exp<strong>an</strong>sion ValvesTable AC/IN-10-A — Cooling Bleed TXV Kits – Single Direction FlowLiquid Line Gas LineModel Used With Connection Connection ShippingNumber AC Units Dia. I.D. (In.) Dia. I.D. (In.) Weight (Ibs.) Refriger<strong>an</strong>tTAYTXVA0B5C 1-1 1 /2 Ton 1 5/4/8 2 R-22TAYTXVA0C5C 2-2 1 /2 Ton 5 3/16/4 2 R-22TAYTXVA0E5C 3-3 PHASED OUT/2 Ton 3 7/8/8 2 R-22TAYTXVA0G5C 4 Ton 3/8 1 1 /8 2 R-22TAYTXVA0H5C 5-6 Ton 3/8 1 1 /8 2 R-22Exp<strong>an</strong>sion Valve TXVCooling KitTable AC/IN-10-B — Cooling Non-Bleed TXV Kits – Single Direction FlowLiquid Line Gas LineModel Used With Connection Connection ShippingNumber AC Units Dia. I.D. (In.) Dia. I.D. (In.) Weight (Ibs.) Refriger<strong>an</strong>tTAYTXVA0B3C 1-1 1 /2 Ton 1 5/4/8 2 R-22TAYTXVA0C3C 2-2PHASED OUT1 /2 Ton 5 3/16/4 2 R-22TAYTXVA0E3C 3-3 1 /2 Ton 3 7/8/8 2 R-22TAYTXVA0G3C 4 Ton 3/8 1 1 /8 2 R-22TAYTXVA0H3C 5-6 Ton 3/8 1 1 /8 2 R-22Table AC/IN-10-C — Heat Pump Non- Bleed TXV Kits (also for cooling) – Dual Direction FlowLiquid Line Gas LineModel Used With Connection Connection ShippingNumber AC Units Dia. I.D. (In.) Dia. I.D. (In.) Weight (Ibs.) Refriger<strong>an</strong>tTAYTXVH0B3C 1-1 1 /2 Ton 1 5/4/8 3 R-22TAYTXVH0C3C 2-2PHASED OUT1 /2 Ton 5 3/16/4 3 R-22TAYTXVH0E3C 3-3 1 /2 Ton 3 7/8/8 3 R-22TAYTXVH0G3C 4 Ton 3/8 1 1 /8 3 R-22TAYTXVH0H3C 5-6 Ton 3/8 1 1 /8 3 R-22Exp<strong>an</strong>sion Valve TXVHeat Pump Kit*Table AC/IN-10-D— Cooling/Heat Pump Non-Bleed TXV Kits - Dual Direction Flow*Liquid Line Gas LineModel Used With Connection Connection ShippingNumber AC Units Dia. I.D. (In.) Dia. I.D. (In.) Weight (Ibs.) Refriger<strong>an</strong>tPHASED OUTTAYTXVH0D3C 2 1 /2 -3 Ton 3/8 1 1 /8 2 R-22TAYTXVH0G3C 4 -5 Ton 3/8 1 1 /8 2 R-22* Used with TXH coils only where approved for use with 2 compressor systems.Effective 1/1/06AC/IN-10For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Refriger<strong>an</strong>t Line SetsTable AC/IN-11-A — Refriger<strong>an</strong>t Line SetsModel Gas Line23 Liquid Line Tonnages/W Tonnages/W ShippingNumber Dia. O.D. Dia. O.D. Length R-22 R-410A WeightTAYREFLN125 5/81/4 25 1 & 1 1 /2 13TAYREFLN130 5/81/4 30 1 & 1 1 /2 15TAYREFLN140 5/81/4 40 1 & 1 1 /2 20TAYREFLN150 5/81/4 50 1 & 1 1 /2 28TAYREFLN225 3/45/16 25 2 & 2 1 /2 2 1 /2 15TAYREFLN230 3/45/16 30 2 & 2 1 /2 2 1 /2 18TAYREFLN240 3/45/16 40 2 & 2 1 /2 2 1 /2 23TAYREFLN250 3/45/16 50 2 & 2 1 /2 2 1 /2 32TAYREFLN325 7/83/8 25 3 & 3 1 /2 4 & 5 20TAYREFLN330 7/83/8 30 3 & 3 1 /2 4 & 5 24TAYREFLN340 7/83/8 40 3 & 3 1 /2 4 & 5 30TAYREFLN350 7/83/8 50 3 & 3 1 /2 4 & 5 39TAYREFLN425 1 1 /813/8 25 4, 5, & 6 20TAYREFLN430 1 1 /813/8 30 4, 5, & 6 24TAYREFLN440 1 1 /813/8 40 4, 5, & 6 30TAYREFLN450 1 1 /813/8 50 4, 5, & 6 39TAYREFLN550 1/21/4 50 1 & 1 1 /2 26TAYREFLN625 5/85/16 25 2 15TAYREFLN630 5/85/16 30 2 17TAYREFLN640 5/85/16 40 2 22TAYREFLN650 5/85/16 50 2 29TAYREFLN725 3/43/8 25 3 & 3 1 /2 19TAYREFLN730 3/43/8 30 3 & 3 1 /2 22TAYREFLN740 3/43/8 40 3 & 3 1 /2 28TAYREFLN750 3/43/8 50 3 & 3 1 /2 351 Gas line is 7/8 O.D. but exp<strong>an</strong>ded out to 1-1/8 on the ends.2 Gas line 90 o bend one end.3 Gas line insulation 1/2" thickness.Note: Contains a holding charge of Nitrogen.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.AC/IN-11 Effective 1/1/06


Base P<strong>an</strong> SizesTable AC/IN-12-A — Base P<strong>an</strong> 450 X 37 X 34 46 X 37 X 34 42 X 37 X 34Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models2TTX4048B 2TWX4042B 2TTX4042B 2TWX4036B 4TTX6036B 2TWX4030B2TTX4060B 2TWX4048B 2TTX5024B 2TWX5030A 2TWX5024A2TTX5036B 2TWX4060B 2TTX5030B 4TWX4036B2TTX5042B 2TWX5036A 4TTX4042B 4TWX6036B2TTX5048B 2TWX5042A2TTZ9030B 2TWX5048A2TTZ9036B 2TWZ9030B2TTZ9048B 2TWZ9036B2TTZ9060B 2TWZ9048B4TTX4048B 2TWZ9060B4TTX4060B 4TWX4042B4TTX6048B 4TWX4048B4TTX6060B 4TWX4060B4TWX6048B4TWX6060BTable AC/IN-12-B — Base P<strong>an</strong> 348 X 33 X 30 44 X 33 X 30 40 X 33 X 30Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models4TWX4024B 4TTX4036B 2TWX4024B 2TTX4018B 2TWX4018B4TWX4030B 4TTX6024B 4TWX6024B 2TTX4024B 4TWX4018B2TTX4030B2TTX4036B4TTX4018B4TTX4024B4TTX4030BTable AC/IN-12-C — Base P<strong>an</strong> 441 X 37 X 34 37 x 37 x 34 33 X 37 X 34Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models2TTR2060B 2TWR2060A 2TTR4042A 2TWR3036A 2TTR3042A 2TWR1060A2TTR3048A 2TWR3042A 4TTR4042A 2TWR4036A 4TTR2060A 2TWR4030A2TTR3060A 2TWR3048A 4TWR4036A 4TWR2048A2TTR4048A 2TWR3060A2TTR4060A 2TWR4042A4TTR4048A 2TWR4048A4TTR4060A 2TWR4060A4TWR2060A4TWR4042A4TWR4048A4TWR4060AEffective 1/1/06AC/IN-12For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Base P<strong>an</strong> SizesTable AC/IN-13-A — Base P<strong>an</strong> 341 X 33 X 30 37 X 33 X 30 33 X 33 X 30Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models4TTR2048A 4TWR2042A 2TTR1060A 2TWR2048A 2TTR2042B 2TWR1042A4TWR4024A 2TTR2048A 2TWR3030A 2TTR3030A 2TWR1048A4TWR4030A 2TTR4030A 4TWR4024A 2TTR3036A 2TWR2036A2TTR4036A 4TWR4018A 2TTR4018A 2TWR2042A4TTR2042A 2TTR4024A 2TWR4018A4TTR4036A 4TTR2018A 4TWR2018A4TTR2024A 4TWR2024A4TTR2030A 4TWR2030A4TTR2036A 4TWR2036A4TTR4018A4TTR4024A4TTR4030ATable AC/IN-13-B — Base P<strong>an</strong> 233 X 29 X 26 29 X 29 X 26 26 X 29 X 26Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models2TTR2036A 2TWR3018A 2TTR1042A 2TWR1030A 2TTR1030A 2TWR1018A2TTR3024A 2TWR3024A 2TTR1048A 2TWR1036A 2TTR1036A 2TWR1024A2TTR2024A 2TWR2018A 2TTR2018A2TTR2030A 2TWR2024A 2TTR3018A2TWR2030BTable AC/IN-13-C — Base P<strong>an</strong> 126 X 20 X 19Cooling Models Heat Pump Models2TTR1018A2TTR1024AFor complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.AC/IN-13 Effective 1/1/06


Base P<strong>an</strong> SizesTable AC/IN-14-A — Base P<strong>an</strong> 441 X 37 X 34 37 X 37 X 34 33 X 37 X 34Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models2TTA0072A 2TWA0072A 2TWA3036A 2TTA3042A 2TWA0060A2TTA3048A 2TWA2060A 2TWB3036A 2TTB3042A 2TWB0060A2TTA3060A 2TWA3042A2TTB3048A 2TWA3048A2TTB3060A 2TWA3060A2TWB2060A2TWB3042A2TWB3048A2TWB3060ATable AC/IN-14-B — Base P<strong>an</strong> 337 X 33 X 30 33 X 33 X 30Cooling Models Heat Pump Models Cooling Models Heat Pump Models2TTA2048A 2TWA2048A 2TTA0060A 2TWA0042A2TTA2060A 2TWA3030A 2TTA2042A 2TWA0048A2TTB2048A 2TWB2048A 2TTA3030A 2TWA2036A2TTB2060A 2TWB3030A 2TTA3036A 2TWA2042A2TTB0060A 2TWB0042A2TTB2042A 2TWB0048A2TTB3030A 2TWB2036A2TTB3036A 2TWB2042ATable AC/IN-14-C — Base P<strong>an</strong> 233 X 29 X 26 29 X 29 X 26 26 X 29 X 26Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models2TTA2036A 2TWB3018A 2TTA0042A 2TWA0030A 2TTA0030A 2TWB0012A2TTB2036A 2TWB3024A 2TTA0048A 2TWA0036A 2TTA0036A 2TWB0018A2TTB3024A 2TTA2030A 2TWA2030A 2TTB0030A 2TWB0024A2TTB2024A 2TWB0030A 2TTB0036A 2TWB2018A2TTB2030A 2TWB0036A 2TTB0042A2TWB2024A 2TTB0048A2TWB2030A 2TTB2018A2TTB3018AEffective 1/1/06AC/IN-14For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Equipment DateIdentificationThe nine digit serial numbers on all <strong>Tr<strong>an</strong>e</strong> central air conditioning <strong>an</strong>d heatingproducts are employed to identify the year <strong>an</strong>d fiscal week of product m<strong>an</strong>ufacture.Year of m<strong>an</strong>ufacture .......................... First digit ................................... M124X04CFFiscal week of m<strong>an</strong>ufacture ............... Second <strong>an</strong>d third digit ............... M124X04CFDay of week of m<strong>an</strong>ufacture .............. Fourth digit ............................... M124X04CFConsecutive order of production ........ Last Five digits ......................... M124X04CFException – Accessories are <strong>an</strong> exception to the nine digit serial numberassignment <strong>an</strong>d may have only three digits to indicate date code.Coils which have only three digits to indicate date code are <strong>an</strong> exceptionto the nine digit serial number assignment.YEAR DESIGNATIONS FROM 1980<strong>Residential</strong>, ID & OD1 Duc<strong>an</strong>e Oil1 <strong>Residential</strong>, ID &OD1 Duc<strong>an</strong>eOil1Light Commercial Horizontal Light Commercial HorizontalYear Products & Compressors Gas Furnaces2 Year Products & Compressors Gas Furnaces21980 O,A L 1995 K 951981 T M 1996 L 961982 U N 1997 M 971983 W P 1998 N 981984 X Q 1999 P 991985 Y 85 2000 R —1986 S 86 2001 Z —1987 B 87 2002 2 —1988 C 88 2003 3 —1989 D 89 2004 4 —1990 E 90 2005 5 —1991 F 91 2006 6 —1992 G 92 2007 7 —1993 H 93 2008 8 —1994 J 94 2009 9 —1 Beginning with 1/1/96 (L01) Duc<strong>an</strong>e oil furnace production uses same datecode method as gas furnace. Prior to 1/1/96 Duc<strong>an</strong>e serial number usedlast four digits = date code, example HA1234569540 1995, 40th week.Example: 123456-8 5 4 0Year of m<strong>an</strong>ufactureFiscal week of m<strong>an</strong>ufacture2 Dedicated horizontal gas furnaces, production ceased after introduction ofconvertible furnaces.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.AC/IN-15 Effective 1/1/06


Refriger<strong>an</strong>t HCFC 22 (R-22)Tables contain no allow<strong>an</strong>ces for vertical lift!Table AC/IN-16-A — Allowable Suction Line Diameters <strong>an</strong>d Capacities (R-22)Note 1: * indicates values more th<strong>an</strong> 10% capacity loss.Note 2: --- indicates values more th<strong>an</strong> 15% capacity loss.Table AC/IN-16-B — Liquid Line Selection Table for R-22 SystemsRefriger<strong>an</strong>t Line Limits1. Do not use traps.2. The suction line diameter must be one of the sizes listed.3. Use the recommended liquid line size unless the total pressure drop (friction lossplus liquid lift) exceeds: 35 PSI.4. Refer to 7½ - 20 ton section to determine appropriate refriger<strong>an</strong>t line size for 7½, 10,12½, 15 <strong>an</strong>d 20 ton split systems.5. XL19i - Max length = 80 – of that max length, 25 feet may be vertical.Effective 1/1/06This page contains limited data for <strong>an</strong> unskilled user to fully determine if the application will work or toselect required accessories. Please refer to publication #22-3317-01 for complete details <strong>an</strong>d examples.AC/IN-16For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Refriger<strong>an</strong>t HFC 410A (R-410A)Tables contain no allow<strong>an</strong>ces for vertical lift!Table AC/IN-17-AAllowable Liquid Line Diameters <strong>an</strong>d Pressure DropsNote 1: A bl<strong>an</strong>k space indicates a pressure drop of over th<strong>an</strong> 50 PSI.Note 2: Other existing sources of pressure drop such as (solenoid valves, etc.) must be considered.Note 3: A vertical run with a heat pump system always results in a liquid lift (heating or cooling).Note 4: The smallest liquid line diameter that results in a total liquid line pressure drop of 50 PSI or less results in the most reliable system (fewer pounds of R-410A).Table AC/IN-17-BAllowable Suction Line Diameters <strong>an</strong>d Capacity LossesNote * Rated tube size.Note 1: Shaded value indicates more th<strong>an</strong> 10% capacity loss.Note 2: Bl<strong>an</strong>k space indicates more th<strong>an</strong> 15% capacity loss.Refriger<strong>an</strong>t Line Limits1. Do not use traps.2. The suction line diameter must be one of the sizes listed. Use the actual tonnage ofthe system in selecting line sizes.3. Use the recommended liquid line size unless the total pressure drop (friction lossplus liquid lift) exceeds: 50 PSI.4. XL16i - Max length = 80 – of that max length, 25 feet may be vertical.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.This page contains limited data for <strong>an</strong> unskilleduser to fully determine if the application will workor to select required accessories. Please refer topublication #22-3317-01 for complete details <strong>an</strong>dexamples.AC/IN-17 Effective 1/1/06


Effective 1/1/06AC/IN-18For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.AC/IN-19 Effective 1/1/06


7 1/2 - 20 Ton (HCFC-22)Split System Refriger<strong>an</strong>t PipingTTA Liquid Suction Applicable line length <strong>an</strong>d rise:: x=total line length (hor+vert) : y=total line rise090a 1/2 1- 3/8120a 1/2 1- 3/8 For 0


Br<strong>an</strong>ch Circuit Wire Sizing Table/Heater De-Rating ChartBRANCH CIRCUIT WIRE SIZING TABLE(Based on 2% Voltage Drop)Chart is based on 75˚ C. wire. (Types FEPW, RH, RHW, THHW, THW, THWN, XHHW, USE, AND ZW.)Use Chart For Wire Sizing Only. Refer To Electrical Code, (Or Product Specs.) For Fuse SizingSuitable for 1 Ph. or 3 Ph. CircuitsDISTANCE (POWER SUPPLY TO LOAD) IN FEET (208-230V)75˚ C. Insulation; 30˚ C. Ambient Temp. (80˚ F.)Not more th<strong>an</strong> three conductors per raceway10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 1751015#12 Copperor#10 Aluminum20REQUIRED BRANCH CIRCUIT AMPACITY253035404550556065707580859095100105110115120125130#10 Copperor#8 Aluminum#8 Copperor#6 Aluminum#6 Copperor#4 Aluminum#4 Copperor#2 Aluminum#2 Copperor#0 Aluminum50 100 150 200 250 300 350Dist<strong>an</strong>ce (power supply to load in feet (460V).See National Electrical Code for Temperature corrections <strong>an</strong>d other variables. All wiring must comply with Local CodesHeater De-Rating ChartThe output of electric heaters, applied at voltages other th<strong>an</strong> the rated 240 or 480 volts, c<strong>an</strong> beeasily determined with the use of this chart.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.AC/IN-21 Effective 1/1/06


Basic Air Conditioning FormulasTO DETERMINETotal AirflowInfiltration or VentilationNumber of Air Ch<strong>an</strong>gesPer Hour – TotalEXPRESSEDASCFM TCFM oN TBasic Air Conditioning FormulasCOOLINGApplicationN T V1. CFMGuideT =60 min./hr.2. CFM o =N O V60 min./hr.3. N T =CFM T (60 min./hr.)VHEATING <strong>an</strong>d/or HUMIDIFYINGN T V1. CFM T =60 min./hr.N o V2. CFM o =60 min./hr.CFM T (60 min./hr.)3. N T =VNumber of Air Ch<strong>an</strong>gesPer Hour – Outdoor AirN o4.N o =CFM o (60 min./hr.)V4. N o =CFM o (60 min./hr.)VTotal Heat (H T )Btuh5.H T = CFM T x 4.5 x (h 1 – h 2 ) = Btuh6. H T = CFM T x 4.5 x (h 2 – h 1 ) = BtuhSensible Heat (H S )Btuh7.H S = CFM T x 1.08 x (T 1 – T 2 ) = Btuh8. H S = CFM T x 1.08 x (T 2 – T 1 ) = BtuhLatent Heat (H L )Btuh9.H L = CFM T x .68 x (W 1 – W 2 ) = Btuh10. H L = CFM T x .68 x (W 2 – W 1 ) = BtuhEntering Air Temperature (T 1 )(Mixed Air)°F. D.B.11.CFMT 1 = t 1 + oCFMx (t 2 – t 1 ) = °F.D.B. 112. TCFM 1 = t 1 – o x (t 1 – t 2 ) = °F.D.B. 2T CFM T1 If duct heat gain is a factor, add to T 1 :2 If duct heat loss is a factor, subtract from T 1 :Duct Heat Gain (Btuh)CFM T x 1.08Duct Heat Loss (Btuh)CFM T x 1.08Leaving Air D.B.Temperature (T 2 )°F. D.B.13.T 2 = T 1 –H SCFM T x 1.08= °F.D.B.14. T 2 = T 1 +H SCFM T x 1.08= °F.D.B.Required AirflowCFM T15.CFM T =ORCFM T =H S (total)1.08 x (T 1 – T 2 )H S (internal)31.08 x (t 1 – T 2 )= CFM= CFM3 Sensible load of outside air not included16. CFM T =H S1.08 x (T 2 – T 1 )= CFMEnthalpy – Leaving Air (h 2 )Btu/lb.dry air17.h 2 = h 1 –H TCFM T x 4.5= Btu/lb. dry air18. h 2 = h 1 +H TCFM T x 4.5= Btu/lb. dry airLeaving Air W.B. Temperature°F.W.B.19.Refer to Enthalpy Table <strong>an</strong>d read W.B. temperaturecorresponding to enthalpy of leaving air (h 2 ) (see #17).20.Refer to Enthalpy Table <strong>an</strong>d read W.B. temperaturecorresponding to enthalpy of leaving air (h 2 ) (see #18).Heat Required to EvaporateWater Vapor Added toVentilation AirHumidification RequirementsBtuhLbs.water/hr.21.H L = CFM o x .68 (W 3 – W o ) = Btuh( )Excess Latent CapacityMake up of System x % Run Time23.= = lbs./hr.Moisture1060 Btu/lb.(Industrial Process Work)22. H L = CFM o x .68 (W 3 – W o ) = Btuh24.Make up( Moisture)H L loss Btuh (see #22)= = lbs./hr.1060 Btu/lb.CFM TCFM oN TN oVH TH SH L* h 1* h 2T 1T 2T adpt 1t 2W 1W 2W 3W o===================LEGENDTotal airflow cubic feet/min.Outdoor air cubic feet/min.Total air ch<strong>an</strong>ges per hourOutdoor air, air ch<strong>an</strong>ges per hourVolume of space cubic feetTotal heat BtuhSensible heat BtuhLatent heat BtuhEnthalpy or total heat of entering airEnthalpy or total heat of leaving airTemperature of entering airTemperature of leaving airApparatus dewpointIndoor design temperatureOutdoor design temperatureGrains of water/lb. of dry air at entering conditionGrains of water/lb. of dry air at leaving conditionGrains of water/lb. of dry air at indoor design conditionsGrains of water/lb. of dry air at outdoor design conditions* See Enthalpy of air (Total Heat Content of Air) Table for exact values.Btu/lb.Btu/lb.°F.D.B.°F.D.B.°F.D.B.Grains/lb.Grains/lb.Grains/lb.Grains/lb.The air const<strong>an</strong>ts below apply specifically to st<strong>an</strong>dard air which isdefined as dry air at 70°F <strong>an</strong>d 14.7 P.S.I.A. (29.92 in. mercury column).They c<strong>an</strong>, however, be used in most cooling calculations unless extremelyprecise results are desired.4.5 (To convert CFM to lbs./hr.)4.5 =60 min./hr.13.33DERIVATION OF AIR CONSTANTSor 60 X .075Where 13.33 is the specific volume of st<strong>an</strong>dard air (cu.ft./lb.) <strong>an</strong>d.075 is the density (lbs./cu.ft.)1.08 =.24 X 6013.33or .24 X 4.5.24 BTU = specific heat of st<strong>an</strong>dard air (BTU/LB/°F).68 =Where:6013.33X106070001060 = Average Latent Heat of water vapor (BTU/LB.).7000 = Grains per lb.or 4.5 X10607000Effective 1/1/06AC/IN-22For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Low Ambient AccessoriesCooling ModelsModelFamily 55 o F 45 o F 30 o F O o FXL19iXL16iXL15iXL14iR-22 / R-410AXR14R-22 / R-410AXR13XR12 - R-410AXR12 - R-222TTA3 /2TTA2 / 2TTA02.5 to 5 TonXR111.5 to 2 TonXR11XB13XB122.5 to 5 TonXB10TTB012 thru 024AsShippedAsShippedAsShippedAsShippedAsShippedAsShippedAsShippedAsShippedAsshippedAsShippedAsShippedAsShippedAsshippedAsShippedAsShippedAsShippedAsShippedAsShippedNotes:1 Scroll compressors unload during the off cycle <strong>an</strong>d do not require hard start components due to refriger<strong>an</strong>t pressure differential. However, it isrecommended to install start kit when operating below 30°F.2 For all systems employing head pressure control, a non-bleed thermal exp<strong>an</strong>sion valve (NB-TXV) is required. TWE060A has a factory installed bleedport TXV. If belt drive is preferred (TWE060A), it is recommended to ch<strong>an</strong>ge the TXV to a non-bleed type.3 If off cycle time exceeds 30 minutes at low outdoor ambient conditions, it is recommended to install a liquid line solenoid valve.a) If solenoid valve is required, pressure drop across the solenoid valve plus liquid line pressure drop shall be no greater th<strong>an</strong> 35 PSI for R-22 systems<strong>an</strong>d 50 PSI for R410A systems.4 Wind shields may be required, please refer to the following pages to locate documentation regarding windshields.5 System indoor airflow shall be no less th<strong>an</strong> 370 CFM / Ton when applying head pressure control.6 Check Product Data General Specification page in order to determine if the condensing unit ships with required components such as cr<strong>an</strong>kcase heat orstart components.7 If non bleed thermal exp<strong>an</strong>sion valve is used in a system bearing a reciprocating style compressor, the condensing unit must have quick start components.Check Product Data for factory-installed components in order to determine if a quick start accessory is required.8 BAYLOAM104 includes integrated quick start kit.* Please refer to Product Data.** BAYCCHT (Cr<strong>an</strong>kcase Heater) is factory installed.For a detailed Application Bulletin on required accessories <strong>an</strong>d wind shields for lowoutdoor ambient operation, please contact your Territory M<strong>an</strong>ager or Local FSR.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.AY28X079 TXV-NB7 BAYCCHT* Not ApprovedAY28X079 TXV-NB7 BAYCCHT* Not ApprovedAY28X079 TXV-NB7 BAYCCHT* Not ApprovedTXV7 AY28X079 TXV-NB7 BAYCCHT* Not ApprovedTXV7 AY28X079 TXV-NB7 BAYCCHT* Not ApprovedTXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT*TXV7 AY28X079 TXV-NB7 BAYCCHT* Not ApprovedTXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT*TXV7 AY28X079 TXV-NB7 ** BAYLOAM103 TXV-NB7 **TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT*TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM104 TXV-NB7 BAYCCHT*TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT*TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT*TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT*TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM104 TXV-NB7 BAYCCHT*Quick StartKitQuick StartKit3 phasenot neededQuick StartKitQuick StartKit8Quick StartKitQuick StartKitQuick StartKitQuick StartKit8SolenoidValve3SolenoidValve3SolenoidValve3SolenoidValve3SolenoidValve3SolenoidValve3SolenoidValve3SolenoidValve3SolenoidValve3AC/IN-23 Effective 1/1/06


Low Ambient AccessoriesHeat Pump ModelsModelFamily 55 o F 45 o F 30 o F34 O o F34XL19iXL16iXL15iXL14iR-22 / R-410AXR14R-22 / R-410AXR13XR12 - R410AXR12 - R-22XR11XB13XB12XB102TWA3 /2TWA2 / 2TWA0AsShippedAsShippedAsShippedAsShippedAsShippedAsShippedAsShippedAsShippedAsShippedAsShippedAsShippedAsShippedAsShippedAs Shipped AY28X084 TXV-NB7 BAYCCHT* Not ApprovedAs Shipped AY28X084 TXV-NB7 BAYCCHT* Not ApprovedAs Shipped AY28X084 TXV-NB7 BAYCCHT* Not ApprovedTXV-NB7 AY28X084 TXV-NB7 BAYCCHT* Not ApprovedTXV-NB7 AY28X084 TXV-NB7 BAYCCHT* Not ApprovedTXV-NB7 AY28X084 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* Not ApprovedTXV-NB7 AY28X084 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6TXV-NB7QuickStartKitAY28X084TXV-NB7QuickStartKitBAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6TXV-NB7TXV-NB7TXV-NB7QuickStartKitQuickStartKit3phaseAY28X084AY28X084TXV-NB7TXV-NB7QuickStartKitQuickStartKitBAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6Quick StartKit6Quick StartKit6Quick StartKit6Quick StartKit6Quick StartKit6Quick StartKit6AY28X084 TXV-NB7 3 phase ** BAYLOAM103 TXV-NB7 ** 3 phaseNotes:1 Scroll compressors unload during the off cycle <strong>an</strong>d do not require hard start components due to refriger<strong>an</strong>t pressure differential. However, it isrecommended to install a start kit when operating below 30°F.2 For all systems employing head pressure control, a non-bleed thermal exp<strong>an</strong>sion valve (NB-TXV) is required. All heat pump exp<strong>an</strong>sion valve accessoriesare non-bleed type. TWE060A has a factory installed bleed port TXV. If belt drive is preferred (TWE060A), it is recommended to ch<strong>an</strong>ge the TXV toa non-bleed type.3 Wind shields may be required, please refer to the following pages to locate documentation regarding windshields.4 System indoor airflow shall be no less th<strong>an</strong> 370 CFM / Ton.5 Do not use solenoid valves with heat pump systems.6 Check Product Data General Specification page in order to determine if the heat pump unit ships with required components such as cr<strong>an</strong>kcase heat orstart components.7 If non bleed thermal exp<strong>an</strong>sion valve is used in a system bearing a reciprocating style compressor, the condensing unit must have quick start components.Check Product Data for factory-installed components in order to determine if a quick start accessory is required.* Please refer to Product Data.** BAYCCHT (Cr<strong>an</strong>kcase Heater) is factory installed.For a detailed Application Bulletin on required accessories <strong>an</strong>d wind shields for lowoutdoor ambient operation, please contact your Territory M<strong>an</strong>ager or Local FSR.Effective 1/1/06AC/IN-24For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.


Wind ShieldsWind Shields are required to blockprevailing winds across condensercoil. In applications where coolingoperation is required to 0°F, windshields are a Must. Use the followingguidelines for your application.Notes:Minimum working clear<strong>an</strong>ce must be in compli<strong>an</strong>ce with the National Electric Code. Currently,the minimum clear<strong>an</strong>ce between a wood or suitable grounding material type fence requiresminimum 3 feet. If other material is used to form the windshield, the minimum space may beincreased to 3.5 feet. Please consult the 2002 Edition of the National Electric Code, Article 110for the most up to date information, please refer to the most current National Electric Code.For a detailed Application Bulletin on required accessories <strong>an</strong>d wind shieldsfor low ambient operation, please contact your Territory M<strong>an</strong>ager or Local FSR.For complete equipment / combinationselections <strong>an</strong>d installation instructions, pleaserefer to Product Data <strong>an</strong>d/or Installers Guides.AC/IN-25 Effective 1/1/06


P.O. Box 9010Tyler TX 75711-9010http://www.tr<strong>an</strong>e.comA Business of Americ<strong>an</strong> St<strong>an</strong>dardComp<strong>an</strong>ies.Literature Order NumberFile No. Pub. No. 22-8301-15 1/06Supersedes Pub. No. 22-8301-14 10/05(Electronic Only)Stocking locationSince <strong>Tr<strong>an</strong>e</strong> has a policy of continuous product improvement, it reserves the right to ch<strong>an</strong>ge design <strong>an</strong>dspecifications without notice.© 2006 Americ<strong>an</strong> St<strong>an</strong>dard All rights reservedPI (L)