HANGING BEAM SUPPORTING CEILING LOADS ONLYAS 4055 CLASSIFICATION C1, C2 AND C3ceiling mass - 20 kg/m 2ceiling load width (mm) 1800 2400 3000 3600 4200 4800Member size DxB (mm)Maximum Hanging Beam span (mm)<strong>15</strong>0x35 3<strong>15</strong>0 2750 2450 2250 2050 1950170x35 3550 3100 2750 2500 2350 2<strong>15</strong>0190x35 3950 3400 3050 2800 2550 2400200x35 4<strong>15</strong>0 3600 3200 2900 2700 2500240x35 4850 4200 3750 3450 3<strong>15</strong>0 29502/<strong>15</strong>0x35 3950 3600 3350 3<strong>15</strong>0 3000 28502/170x35 4500 4050 3800 3550 3400 32502/190x35 5000 4550 4200 3950 3750 36002/200x35 5250 4800 4450 4200 3950 38002/240x35 5950 5550 5250 5000 4750 44502/290x35 6750 6350 6050 5750 5500 53002/300x35 6900 6500 6<strong>15</strong>0 5900 5650 5450<strong>15</strong>0x42 3350 3050 2700 2450 2250 2100170x42 3800 3400 3000 2750 2550 2400190x42 4200 3750 3350 3050 2800 2650200x42 4450 3900 3500 3200 2950 2750240x42 5300 4600 4100 3750 3450 3250290x42 6<strong>15</strong>0 5450 4900 4450 4100 3850300x42 6300 5650 5050 4600 4250 39502/<strong>15</strong>0x42 4200 3800 3550 3350 3<strong>15</strong>0 30502/170x42 4750 4300 4000 3800 3600 34502/190x42 5250 4850 4500 4200 4000 38502/200x42 5450 5100 4700 4450 4200 40502/240x42 6<strong>15</strong>0 5800 5500 5200 5000 48002/290x42 6950 6600 6250 5950 5750 55002/300x42 7<strong>15</strong>0 6750 6400 6100 5850 56502/360x42 8050 7600 7250 6950 6700 64502/400x42 8600 8<strong>15</strong>0 7800 7450 7200 6950<strong>15</strong>0x58 3700 3350 3<strong>15</strong>0 2900 2650 2500170x58 4200 3800 3550 3250 3000 2800200x58 4950 4500 4100 3750 3450 3250240x58 5750 5350 4850 4400 4050 3800300x58 6700 6300 5900 5400 5000 4650360x58 7550 7100 6750 6250 5750 5400400x58 8100 7650 7250 6800 6300 5850 5450x58 8800 8300 7900 7450 6900 5 6450 10300x75 7000 6600 6250 6000 5650 5300400x75 8450 8000 7650 7300 7050 6650525x75 10100 9600 9200 8800 8500 5 8200 10NOTES:1. D = member depth, B = member breadth, NS = not suitable.2. The above table was based on a maximum ceiling mass of 20 (kg/m 2 ).3. Minimum bearing length = 70 mm at end supports.4. Restraint value for slenderness calculations is <strong>15</strong>00 mm5. Not all sizes of <strong>SmartLVL</strong> <strong>15</strong> in this table are stocked in each state. (F17 sizes of 120, 140, 190 and 290 mm depths not currently stocked in WA).Please check with your supplier before ordering6. Values in subscript indicate extra bearing length in excess of the min 70 mm<strong>SmartLVL</strong> <strong>15</strong> <strong>Design</strong> <strong>Guide</strong> 67

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!