<strong>water</strong> <strong>chillers\MCC</strong>MCC AIR-COOLED WATER CHILLERS WITH CENTRIFUGALFANSThe package air-cooled <strong>water</strong> chillers and cycle reversing heat pumps ofthe MCC series are designed to be installed indoors as part of residentialor commercial duct systems.Designed and developed for R410A refrigerant, the MCC series achievesexceptional levels of energy efficiency thanks to the optimisation of theheat exchangers in terms of plate type and distribution.The design philosophy places a priority on compactness, “plug &play” solutions and easy access to all the components: the logic ofthe PLUG&PLAY PLUMBING, already in the DNA of the whole <strong>water</strong>line, is combined here with the innovative PLUG&PLAY VENTILATIONphilosophy. The continuously modulating adaptive control of the fan flowrate (pressostatic condensation control as a standard feature of all modelsmaking up the range) drastically reduces installation times.PLUG & PLAY VENTILATION SYSTEM:Automatic air flow adaptation based on:- pressure drops in channels- intake air temperatureA standard feature of all units is pressostatic condensation control whichmodulates, by means of a phase cut device, the number of fan revolutionsdepending on the pressure drops on the air side and the inlet air temperature.Air delivery can be configured vertically or horizontally (optional).PLUG & PLAY WATER SYSTEMTo enable immediate application of MCC to the system, 3 different hydronickits are available:- B version: units with evaporator only.- P version: units equipped with evaporator, electric pump and expansiontank.- S version: units equipped with evaporator, electric pump, expansiontank and inertial buffer tank.- Mechanical Y filter (COMPULSORY) supplied as a standard featureon all models to protect the evaporator.ACCESSORIES AVAILABLE- Refrigerant pressure gauges- Antifreeze heating elements on the <strong>water</strong> circuit- Electronic thermostatic valve- Heat recovery (cooling only models)- Special heat exchangers (copper-copper, cataphoresis, Blygold)- Remote microprocessor or simplified control- Base vibration dampers- Metal grilles to protect exchangers- Outlet connectorsSIMPLIFIED MAINTENANCEDirect coupling of the centrifugal fans to the electric motor without anypulleys or belts.The technical / cooling compartment is completely separated from the fancompartment so that checks can be performed while the chiller is operating.Controller accessible from outside the unit.MICROPROCESSOR CONTROL AND REGULATIONNew generation, allows connection with ERGOPossibility of connecting / changing the set-point of the unit based on theoutdoor air temperature read by an ambient probe (optional).The series features 10 models in cooling only version, and cooling capacityranging from 6 to 37 kW, and 10 models with reversible heat pump, andheating capacity ranging from 6 to 41 kW.<strong>196</strong>VM66000305.00


<strong>water</strong> <strong>chillers\MCC</strong>MCC-H06M 07M 09M 06 07 09Power supplyV-ph-Hz230-1-50400-3-50Cooling capacity kW 5,6 6,75 9 5,6 6,8 9,1MCC HB Cooling power input kW 2,61 3,18 4,83 2,58 3,04 4,63MCC HP - HS Cooling power input kW 2,75 3,32 5,2 2,72 3,18 5Heating capacity kW 6,4 7,75 10,2 6,4 7,65 9,95MCC HB Heating power input kW 2,86 3,38 5,2 2,94 3,23 4,9MCC HP - HS Heating power input kW 3 3,52 5,57 3,08 3,37 5,27Maximum power input kW 4 5 7 4 5 7Maximum current absorption A 17,1 19,1 33,6 7,5 9,5 17,4Starting absorbed current A 61,56 82,6 100,2 32,6 35,6 51,2n° of scroll compressor / circuits 1/1 1/1 1/1 1/1 1/1 1/1n° of axial fan 1 1 1 1 1 1Air flow m 3 /h 2.500 2.500 5.500 2.500 2.500 5.500AESP Pa 91 85 140 91 85 135Water flow in cooling mode l/s 0,267 0,323 0,431 0,267 0,325 0,433Water flow in heat pump l/s 0,306 0,369 0,488 0,308 0,365 0,477Water pressure drop (cooling) kPa 4 4,3 34,6 4 4,3 34,9Water pressure drop (heating) kPa 5,1 5,4 42 5,1 5,4 42Available pressure head (cooling) kPa 57,4 55,5 156,7 57,4 55,4 156,4Available pressure head (heating) kPa 55,2 52,9 145,4 55 53,2 147,7Diameter of hydrualic connections " 1 1 1 1/4 1 1 1 1/4Water content escluding optionals dm 3 2,5 2,8 3,3 2,5 2,8 3,3Expansion tank dm 3 1 1 5 1 1 5Buffer tank dm 3 20 20 36 20 20 36Height mm 1.000 1.000 1.160 1.000 1.000 1.160Length mm 1.050 1.050 1.250 1.050 1.050 1.250Width mm 600 600 730 600 600 730Sound power level dB(A) 70 70 78 70 70 78Sound pressure level dB(A) 42 42 50 42 42 50Transport weight * kg 170 180 240 170 180 240Operating weight * kg 173 183 260 173 183 260MCC-HHEAT PUMPS RATED TECHNICAL DATAHEAT PUMPS RATED TECHNICAL DATA12 15 18 22 25 33 37Power supplyV-ph-Hz400-3-50Cooling capacity kW 11,70 14,30 17,60 21,80 25,00 32,40 35,90MCC HB Cooling power input kW 5,73 6,43 7,53 8,93 12,05 14,85 16,25MCC HP - HS Cooling power input kW 6,10 6,80 7,90 9,30 12,60 15,40 16,80Heating capacity kW 13,10 15,50 19,20 23,80 28,20 36,36 40,56MCC HB Heating power input kW 6,10 6,72 7,73 9,23 12,35 15,25 16,75MCC HP - HS Heating power input kW 6,47 7,09 8,12 9,57 12,85 15,75 17,25Maximum power input kW 9 9 11 13 17 19 21Maximum current absorption A 19,4 20,4 23,2 25,2 28,4 34,6 38,2Starting absorbed current A 67,2 77,2 104,2 114,2 134,6 162,6 199,6n° of scroll compressor / circuits 1/1 1/1 1/1 1/1 1/1 1/1 1/1n° of axial fan 1 1 1 1 2 2 2Air flow m 3 /h 5.500 5.500 6.500 6.500 11.000 13.000 13.000AESP Pa 130 120 120 110 125 95 90Water flow in cooling mode l/s 0,561 0,684 0,843 1,043 1,194 1,550 1,715Water flow in heat pump l/s 0,626 0,743 0,920 1,138 1,349 1,729 1,930Water pressure drop (cooling) kPa 37 54 37 44 46 39 37Water pressure drop (heating) kPa 46 63 44 51 58 48 46Available pressure head (cooling) kPa 150 128 138 121 125 125 124Available pressure head (heating) kPa 139 116 128 107 111 112 109Diameter of hydrualic connections " 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4Water content escluding optionals dm 3 4 4 4 5 6 7 8Expansion tank dm 3 5 5 5 5 8 8 8Buffer tank dm 3 36 36 96 96 155 155 155Height mm 1.160 1.160 1.210 1.210 1.400 1.400 1.400Length mm 1.250 1.250 1.650 1.650 2.250 2.250 2.250Width mm 730 730 800 800 800 800 800Sound power level dB(A) 78 78 79 79 80 82 82Sound pressure level dB(A) 50 50 51 51 52 54 54Transport weight * kg 245 250 310 342 450 475 485Operating weight * kg 265 270 388 436 601 627 638* Weights refer to model with pump and buffer tank- Cooling capacity: outdoor air temperature 35°C, <strong>water</strong> temperature 12-7°C- Heating capacity: outdoor air temperature 7°C dry bulb and 6.2°C wet bulb,<strong>water</strong> temperature 40°C/45°C- Sound power measured according to standards ISO 3741 - ISO 3744 and EN29614-1- Sound pressure measured at a distance of 10 m and a height of 1.5 m abovethe ground in a clear field (fan side)198VM66000305.00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!