NEW AQUAREA AIR TO WATER HEAT PUMP - Komfovent

NEW AQUAREA AIR TO WATER HEAT PUMP - Komfovent

NEW AQUAREA AIR TO WATER HEAT PUMP - Komfovent

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Heating Capacity table based on outlet temperature and outside temperatureHeating Capacity CurveAquarea T-CAP. Mono-Bloc Single Phase / Three Phase. Heating. MXF / MXCWH-MXF09D3E5 / WH-MXC09D3E5Tamb HC IP COP HC IP COP HC IP COP HC IP COP HC IP COP HC IP COPLWC 30 30 30 35 35 35 40 40 40 45 45 45 50 50 50 55 55 55-15 9.00 3.28 2.74 9.00 3.55 2.54 9.00 3.95 2.28 9.00 4.34 2.07 9.00 4.77 1.89 9.00 5.20 1.73-7 9.00 2.75 3.27 9.00 3.20 2.81 9.00 3.66 2.46 9.00 4.11 2.19 9.00 4.31 2.09 9.00 4.50 2.002 9.00 2.40 3.75 9.00 2.55 3.53 9.00 2.82 3.19 9.00 3.09 2.91 9.00 3.60 2.50 9.00 4.11 2.197 9.00 1.68 5.36 9.00 1.90 4.74 9.00 2.20 4.09 9.00 2.50 3.60 9.00 2.88 3.13 9.00 3.10 2.9025 13.60 1.54 8.83 13.60 1.75 7.77 13.20 1.97 6.70 12.80 2.18 5.87 12.00 2.45 4.90 11.20 2.71 4.13WH-MXF12D6E5 / WH-MXC12D6E5Tamb HC IP COP HC IP COP HC IP COP HC IP COP HC IP COP HC IP COPLWC 30 30 30 35 35 35 40 40 40 45 45 45 50 50 50 55 55 55-15 12.00 4.79 2.51 12.00 5.00 2.40 11.50 5.21 2.21 11.00 5.42 2.03 10.70 5.86 1.83 10.50 6.30 1.67-7 12.00 3.89 3.08 12.00 4.45 2.70 12.00 5.02 2.39 12.00 5.58 2.15 12.00 5.94 2.02 12.00 6.30 1.902 12.00 3.23 3.72 12.00 3.53 3.40 12.00 3.91 3.07 12.00 4.29 2.80 12.00 4.90 2.45 12.00 5.51 2.187 12.00 2.22 5.41 12.00 2.57 4.67 12.00 3.00 4.00 12.00 3.43 3.50 12.00 3.82 3.14 12.00 4.20 2.8625 13.60 1.59 8.55 13.60 1.80 7.56 13.40 2.14 6.26 13.20 2.47 5.34 12.60 2.70 4.67 12.00 2.93 4.10WH-MXF09D3E8 / WH-MXC09D3E8Tamb HC IP COP HC IP COP HC IP COP HC IP COP HC IP COP HC IP COPLWC 30 30 30 35 35 35 40 40 40 45 45 45 50 50 50 55 55 55-15 9.00 3.28 2.74 9.00 3.55 2.54 9.00 3.95 2.28 9.00 4.34 2.07 9.00 4.77 1.89 9.00 5.20 1.73-7 9.00 2.75 3.27 9.00 3.20 2.81 9.00 3.66 2.46 9.00 4.11 2.19 9.00 4.31 2.09 9.00 4.50 2.002 9.00 2.40 3.75 9.00 2.55 3.53 9.00 2.82 3.19 9.00 3.09 2.91 9.00 3.60 2.50 9.00 4.11 2.197 9.00 1.68 5.36 9.00 1.90 4.74 9.00 2.20 4.09 9.00 2.50 3.60 9.00 2.88 3.13 9.00 3.10 2.9025 13.60 1.54 8.83 13.60 1.75 7.77 13.20 1.97 6.70 12.80 2.18 5.87 12.00 2.45 4.90 11.20 2.71 4.13WH-MXF12D9E8 / WH-MXC12D9E8Tamb HC IP COP HC IP COP HC IP COP HC IP COP HC IP COP HC IP COPLWC 30 30 30 35 35 35 40 40 40 45 45 45 50 50 50 55 55 55-15 12.00 4.79 2.51 12.00 5.00 2.40 12.00 5.45 2.20 12.00 5.90 2.03 11.50 6.28 1.83 11.10 6.66 1.67-7 12.00 3.89 3.08 12.00 4.45 2.70 12.00 5.02 2.39 12.00 5.58 2.15 12.00 5.94 2.02 12.00 6.30 1.902 12.00 3.23 3.72 12.00 3.53 3.40 12.00 3.91 3.07 12.00 4.29 2.80 12.00 4.90 2.45 12.00 5.51 2.187 12.00 2.22 5.41 12.00 2.57 4.67 12.00 3.00 4.00 12.00 3.43 3.50 12.00 3.82 3.14 12.00 4.20 2.8625 13.60 1.59 8.55 13.60 1.80 7.56 13.40 2.14 6.26 13.20 2.47 5.34 12.60 2.70 4.67 12.00 2.93 4.10Cooling Capacity CurveAquarea T-CAP. Mono-Bloc Single Phase / Three Phase. Cooling. MXCMODELS WH-MXC09 WH-MXC12Tamb HC IP COP HC IP COP16 7.00 1.40 5.00 7.50 1.45 5.1725 7.65 1.95 3.92 8.90 2.20 4.0535 7.00 2.25 3.11 10.00 3.60 2.7843 6.25 2.70 2.31 8.00 3.05 2.62Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating Capacity (kW). IP: Power Input (kW)This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance.Hydraulic Pump PerformanceExternal Static Pressure (kPa)706050403020100( 09D3 // 12D6 // 12D9 // 12D3 )0 5 10 15 20 25 30 35Water Flow Rate (L/min)50Pump Speed 1 Pump Speed 2 Pump Speed 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!