PETROLEUM STORAGE TANK (PST)<br />

TANKID#/TYPE 5/UST<br />

INSTALLED: 01/01/1983 STATUS(DATE): REMOVED FROM GROUND (06/05/1995)<br />

CAPACITY(gal.): 550 CONTENTS: USED OIL<br />

TANK MATERIAL/CONTAINMENT: FRP(FIBERGLASS-REINFORCED PLASTIC) / NOT REPORTED<br />

PIPE MATERIAL/CONTAINMENT: FRP(FIBERGLASS-REINFORCED PLASTIC) / NOT REPORTED<br />

TANK/PIPE RELEASE DETECTION: NOT REPORTED / NOT REPORTED<br />

TANK/PIPE CORROSION PROTECTION: NOT REPORTED / NOT REPORTED<br />

SPILL/OVERFILL PROTECTION: AUTO. DELIVERY SHUT/OFF VALVE<br />

TANKID#/TYPE 3/UST<br />

INSTALLED: 01/01/1983 STATUS(DATE): IN USE (NOT REPORTED)<br />

CAPACITY(gal.): 8000 CONTENTS: DIESEL<br />

TANK MATERIAL/CONTAINMENT: FRP(FIBERGLASS-REINFORCED PLASTIC) / SINGLE WALL<br />

PIPE MATERIAL/CONTAINMENT: FRP(FIBERGLASS-REINFORCED PLASTIC) / SINGLE WALL<br />

TANK/PIPE RELEASE DETECTION: NOT REPORTED / AUTO. LINE LEAK DETECTOR (3.0 GPH FOR PRESSURE PIPING)<br />

TANK/PIPE CORROSION PROTECTION: FRP TANK OR PIPING (NONCORRODIBLE) / FRP TANK OR PIPING (NONCORRODIBLE)<br />

SPILL/OVERFILL PROTECTION: AUTO. FLOW RESTRICTOR VALVE<br />

MAP ID# 28<br />

FACILITY INFORMATION<br />

OWNER INFORMATION<br />

ID#: 0063172 FACILITY TYPE: UNIDENTIFIED<br />

NAME: 11422 SPROWLES INC<br />

NAME: NATIONSRENT INC 100<br />

ADDRESS: 4101 GATEWAY DR<br />

ADDRESS: 11422 N STEMMONS FWY<br />

COLLEYVILLE, TX 76034<br />

DALLAS, TX<br />

CONTACT: DONALD R O NEAL<br />

CONTACT: JAMES BRASHEAR<br />

PHONE: 817-545-1959<br />

PHONE: 972/484-6767<br />

TANK INFORMATION<br />

Distance from Property: 0.06 mi. SE<br />

TANKID#/TYPE 1/UST<br />

INSTALLED: 03/01/1992 STATUS(DATE): TEMPORARILY OUT OF USE (12/12/2002)<br />

CAPACITY(gal.): 12000 CONTENTS: DIESEL<br />

TANK MATERIAL/CONTAINMENT: JACKETED (STEEL W/EXTERNAL NONMETALLIC JACKET / FACTORY-BUILT NONMETALLIC<br />

JACKET<br />

PIPE MATERIAL/CONTAINMENT: JACKETED (STEEL W/EXTERNAL NONMETALLIC JACKET) / SINGLE WALL<br />

TANK/PIPE RELEASE DETECTION: AUTOMATIC TANK GAUGE TEST & INVENTORY CNTRL / ANNUAL PIPING TIGHTNESS TEST<br />

(@ 0.1 GPH)<br />

TANK/PIPE CORROSION PROTECTION: CATHODIC PROTECTION - FIELD INSTALLATION / NONMETALLIC FLEXIBLE PIPING<br />

SPILL/OVERFILL PROTECTION: AUTO. FLOW RESTRICTOR VALVE<br />

MAP ID# 29<br />

FACILITY INFORMATION<br />

OWNER INFORMATION<br />

ID#: 0017476 FACILITY TYPE: UNIDENTIFIED<br />

NAME: MOBIL OIL CORPORATION<br />

NAME: 12EC5<br />

ADDRESS: 12596 W BAYAUD AVE STE 100<br />

ADDRESS: 2450 ROYAL LN<br />

LAKEWOOD, CO 80228<br />

DALLAS, TX<br />

CONTACT: ERIC MCPHEE<br />

CONTACT: T.B. NEWMAN<br />

PHONE:<br />

PHONE: 214/851-5202<br />

TANK INFORMATION<br />

Distance from Property: 0.05 mi. SE<br />

TANKID#/TYPE 2/UST<br />

INSTALLED: 01/01/1976 STATUS(DATE): REMOVED FROM GROUND (04/21/1986)<br />

CAPACITY(gal.): 8000 CONTENTS: GASOLINE<br />

TANK MATERIAL/CONTAINMENT: STEEL / NOT REPORTED<br />

PIPE MATERIAL/CONTAINMENT: STEEL / NOT REPORTED<br />

TANK/PIPE RELEASE DETECTION: NOT REPORTED / NOT REPORTED<br />

TANK/PIPE CORROSION PROTECTION: NOT REPORTED / NOT REPORTED<br />

SPILL/OVERFILL PROTECTION: NOT REPORTED<br />

2705 Bee Caves Rd, Suite 330 · Austin, Texas 78746 · phone: 1-866-396-0042 · fax: 512-472-9967<br />