PETROLEUM STORAGE TANK (PST)<br />

TANKID#/TYPE 4/UST<br />

INSTALLED: 01/01/1967 STATUS(DATE): REMOVED FROM GROUND (09/30/1986)<br />

CAPACITY(gal.): 4000 CONTENTS: GASOLINE<br />

TANK MATERIAL/CONTAINMENT: STEEL / SINGLE WALL<br />

PIPE MATERIAL/CONTAINMENT: STEEL / SINGLE WALL<br />

TANK/PIPE RELEASE DETECTION: NOT REPORTED / NOT REPORTED<br />

TANK/PIPE CORROSION PROTECTION: CATHODIC PROTECTION - FIELD INSTALLATION / CATHODIC PROTECTION - FIELD<br />

INSTALLATION<br />

SPILL/OVERFILL PROTECTION: NOT REPORTED<br />

TANKID#/TYPE 3/UST<br />

INSTALLED: 01/01/1967 STATUS(DATE): REMOVED FROM GROUND (09/30/1986)<br />

CAPACITY(gal.): 8000 CONTENTS: GASOLINE<br />

TANK MATERIAL/CONTAINMENT: STEEL / SINGLE WALL<br />

PIPE MATERIAL/CONTAINMENT: STEEL / SINGLE WALL<br />

TANK/PIPE RELEASE DETECTION: NOT REPORTED / NOT REPORTED<br />

TANK/PIPE CORROSION PROTECTION: CATHODIC PROTECTION - FIELD INSTALLATION / CATHODIC PROTECTION - FIELD<br />

INSTALLATION<br />

SPILL/OVERFILL PROTECTION: NOT REPORTED<br />

TANKID#/TYPE 4/UST<br />

INSTALLED: 09/01/1986 STATUS(DATE): IN USE (NOT REPORTED)<br />

CAPACITY(gal.): 12000 CONTENTS: GASOLINE<br />

TANK MATERIAL/CONTAINMENT: FRP(FIBERGLASS-REINFORCED PLASTIC) / SINGLE WALL<br />

PIPE MATERIAL/CONTAINMENT: FRP(FIBERGLASS-REINFORCED PLASTIC) / DOUBLE WALL<br />

TANK/PIPE RELEASE DETECTION: NOT REPORTED / NOT REPORTED<br />

TANK/PIPE CORROSION PROTECTION: FRP TANK OR PIPING (NONCORRODIBLE) / FRP TANK OR PIPING (NONCORRODIBLE)<br />

SPILL/OVERFILL PROTECTION: NOT REPORTED<br />

TANKID#/TYPE 5E/UST<br />

INSTALLED: 09/01/1986 STATUS(DATE): IN USE (NOT REPORTED)<br />

CAPACITY(gal.): 1000 CONTENTS: USED OIL<br />

TANK MATERIAL/CONTAINMENT: FRP(FIBERGLASS-REINFORCED PLASTIC) / DOUBLE WALL<br />

PIPE MATERIAL/CONTAINMENT: FRP(FIBERGLASS-REINFORCED PLASTIC) / SINGLE WALL<br />

TANK/PIPE RELEASE DETECTION: INTERSTITIAL MONITORING WITHIN SECONDARY WALL/JACKET / AUTO. LINE LEAK<br />

DETECTOR (3.0 GPH FOR PRESSURE PIPING)<br />

TANK/PIPE CORROSION PROTECTION: FRP TANK OR PIPING (NONCORRODIBLE) / FRP TANK OR PIPING (NONCORRODIBLE)<br />

SPILL/OVERFILL PROTECTION: AUTO. FLOW RESTRICTOR VALVE<br />

TANKID#/TYPE 3/UST<br />

INSTALLED: 09/01/1986 STATUS(DATE): IN USE (NOT REPORTED)<br />

CAPACITY(gal.): 10000 CONTENTS: GASOLINE<br />

TANK MATERIAL/CONTAINMENT: FRP(FIBERGLASS-REINFORCED PLASTIC) / SINGLE WALL<br />

PIPE MATERIAL/CONTAINMENT: FRP(FIBERGLASS-REINFORCED PLASTIC) / DOUBLE WALL<br />

TANK/PIPE RELEASE DETECTION: NOT REPORTED / NOT REPORTED<br />

TANK/PIPE CORROSION PROTECTION: FRP TANK OR PIPING (NONCORRODIBLE) / FRP TANK OR PIPING (NONCORRODIBLE)<br />

SPILL/OVERFILL PROTECTION: NOT REPORTED<br />

TANKID#/TYPE 2/UST<br />

INSTALLED: 09/01/1986 STATUS(DATE): IN USE (NOT REPORTED)<br />

CAPACITY(gal.): 10000 CONTENTS: GASOLINE<br />

TANK MATERIAL/CONTAINMENT: FRP(FIBERGLASS-REINFORCED PLASTIC) / SINGLE WALL<br />

PIPE MATERIAL/CONTAINMENT: FRP(FIBERGLASS-REINFORCED PLASTIC) / DOUBLE WALL<br />

TANK/PIPE RELEASE DETECTION: NOT REPORTED / NOT REPORTED<br />

TANK/PIPE CORROSION PROTECTION: FRP TANK OR PIPING (NONCORRODIBLE) / FRP TANK OR PIPING (NONCORRODIBLE)<br />

SPILL/OVERFILL PROTECTION: NOT REPORTED<br />

TANKID#/TYPE 1/UST<br />

INSTALLED: 09/01/1986 STATUS(DATE): IN USE (NOT REPORTED)<br />

CAPACITY(gal.): 8000 CONTENTS: DIESEL<br />

TANK MATERIAL/CONTAINMENT: FRP(FIBERGLASS-REINFORCED PLASTIC) / SINGLE WALL<br />

PIPE MATERIAL/CONTAINMENT: FRP(FIBERGLASS-REINFORCED PLASTIC) / DOUBLE WALL<br />

TANK/PIPE RELEASE DETECTION: NOT REPORTED / NOT REPORTED<br />

TANK/PIPE CORROSION PROTECTION: FRP TANK OR PIPING (NONCORRODIBLE) / FRP TANK OR PIPING (NONCORRODIBLE)<br />

SPILL/OVERFILL PROTECTION: NOT REPORTED<br />