Specification - KlÃma
Specification - KlÃma
Specification - KlÃma
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Capacity CombinationSystemRJ040F2HXEBSystemNeo Forte & CrystalCOOLINGIndoor Unit Combination Cooling Capacity (W) Capacity Power Consumption CurrentMaldives P Series & DeluxeHEATINGIndoor Unit Combination Heating Capacity (W) Capacity Power Consumption CurrentOutdoor UnitA B C D % Total A B C D TotalW W AMIN NOM MAX MIN NOM MAX MIN NOM MAXEEREGOutdoor UnitA B C D % Total A B C D TotalW W AMIN NOM MAX MIN NOM MAX MIN NOM MAXEEREG2000 - - - 50% 2000 2100 - - - 2100 1250 2100 2520 300 540 630 1.7 2.5 2.9 3.89 A2600 - - - 65% 2600 2600 - - - 2600 1250 2600 3120 300 750 880 1.7 3.4 4.0 3.47 A3500 - - - 88% 3500 3500 - - - 3500 1250 3500 4200 300 1060 1240 1.7 4.9 5.7 3.30 A2200 - - - 50% 2200 2400 - - - 2400 1000 2400 2990 260 780 910 1.3 3.6 4.2 3.08 D3300 - - - 75% 3300 3100 - - - 3100 1000 3100 3450 260 850 1080 1.3 3.9 4.9 3.65 A4000 - - - 91% 4000 3800 - - - 3800 1000 3800 4370 260 1100 1380 1.3 5.0 6.3 3.45 B1 Unit1 Unit2000 2000 - - 100% 4000 2000 2000 - - 4000 1250 4000 4500 300 1180 1330 1.7 5.4 6.1 3.39 A2000 2600 - - 115% 4600 1740 2260 - - 4000 1300 4000 4500 350 1180 1330 1.9 5.4 6.1 3.39 A2000 3500 - - 138% 5500 1450 2550 - - 4000 1300 4000 4500 350 1180 1330 1.9 5.4 6.1 3.39 A2600 2600 - - 130% 5200 2000 2000 - - 4000 1300 4000 4500 350 1180 1330 1.9 5.4 6.1 3.39 A2600 3500 - - 153% 6100 1700 2300 - - 4000 1300 4000 4500 350 1110 1330 1.9 5.1 6.1 3.60 A2200 2200 - - 100% 4400 2200 2200 - - 4400 1000 4400 4700 280 1160 1390 1.4 5.3 6.4 3.79 A2200 3300 - - 125% 5500 1760 2640 - - 4400 1000 4400 4700 280 1160 1400 1.4 5.3 6.4 3.79 A2200 4000 - - 141% 6200 1560 2840 - - 4400 1000 4400 4700 280 1160 1400 1.4 5.3 6.4 3.79 A3300 3300 - - 150% 6600 2200 2200 - - 4400 1000 4400 4700 280 1160 1400 1.4 5.3 6.4 3.79 A3300 4000 - - 166% 7300 1990 2410 - - 4400 1000 4400 4700 280 990 1400 1.4 4.5 6.4 4.44 A2 Unit2 Unit1. Cooling capacity is based on 27°CDB / 19°CWB (indoor temperature), 35°CDB (outdoor temperature).2. The above is the value for connecting with the following indoor units.- 2000, 2600, 3500W class: Wall Mounted Neo forte & Crystal Series [only for MH***FNEA, MH***FAEA Type]3. Capacities are based on the following conditions:- Corresponding refrigerant piping length : 5m / - Level difference : 0m4. The total ability of connected a indoor unit is up to 6.1 kW (@ Cooling)5. It is impossible to connect the indoor unit for one room only.6. Power consumption include indoor unit power.1. Heating capacity is based on 20°CDB (indoor temperature), 7°CDB/6°CWB (outdoor temperature).2. The above is the value for connecting with the following indoor units.- 2200, 3300, 4000W class: Wall Mounted Madives P Series, Maldives DELUXE [only for AQV**PSBN, AQV***PMEN, AQV***PMBN]3. Capacities are based on the following conditions:- Corresponding refrigerant piping length : 5m / - Level difference : 0m4. The total ability of connected a indoor unit is up to 7.3 kW (@ Heating)5. It is impossible to connect the indoor unit for one room only.6. Power consumption include indoor unit power.HEATINGOutdoor Unit1 Unit2 UnitIndoor Unit Combination Heating Capacity (W) Capacity Power Consumption CurrentA B C D % Total A B C D TotalW W AMIN NOM MAX MIN NOM MAX MIN NOM MAX2200 - - - 50% 2200 2400 - - - 2400 1000 2400 2990 260 780 910 1.3 3.6 4.2 3.08 D2900 - - - 66% 2900 3100 - - - 3100 1000 3100 3450 260 850 1080 1.3 3.9 4.9 3.65 A3800 - - - 86% 3800 3800 - - - 3800 1000 3800 4370 260 1100 1380 1.3 5.0 6.3 3.45 B2200 2200 - - 100% 4400 2200 2200 - - 4400 1000 4400 4700 280 1160 1390 1.4 5.3 6.4 3.79 A2200 2900 - - 116% 5100 1900 2500 - - 4400 1000 4400 4700 280 1160 1400 1.4 5.3 6.4 3.79 A2200 3800 - - 136% 6000 1610 2790 - - 4400 1000 4400 4700 280 1160 1400 1.4 5.3 6.4 3.79 A2900 2900 - - 132% 5800 2200 2200 - - 4400 1000 4400 4700 280 1160 1400 1.4 5.3 6.4 3.79 A2900 3800 - - 152% 6700 1900 2500 - - 4400 1000 4400 4700 280 1020 1400 1.4 4.7 6.4 4.31 AEEREGJungfrau Y-seriesCOOLINGOutdoor Unit1 Unit2 UnitIndoor Unit Combination Cooling Capacity (W) Capacity Power Consumption CurrentA B C D % Total A B C D TotalW W AMIN NOM MAX MIN NOM MAX MIN NOM MAX2500 - - - 63% 2500 2500 - - - 2500 1250 2500 3120 300 750 880 1.7 3.4 4.0 3.33 A3500 - - - 88% 3500 3500 - - - 3500 1250 3500 4200 300 1060 1240 1.7 4.9 5.7 3.30 A2500 2500 - - 125% 5000 2000 2000 - - 4000 1300 4000 4500 350 1180 1330 1.9 5.4 6.1 3.39 A2500 3500 - - 150% 6000 1670 2330 - - 4000 1300 4000 4500 350 1020 1330 1.9 4.7 6.1 3.92 AEEREG1. Heating capacity is based on 20°CDB (indoor temperature), 7°CDB/6°CWB (outdoor temperature).2. The above is the value for connecting with the following indoor units.- 2200, 2900, 3800W class: Wall Mounted Neo forte & Crystal Series [only for MH***FNEA, MH***FAEA Type]3. Capacities are based on the following conditions:- Corresponding refrigerant piping length : 5m / - Level difference : 0m4. The total ability of connected a indoor unit is up to 6.7 kW (@ Heating)5. It is impossible to connect the indoor unit for one room only.6. Power consumption include indoor unit power.1. Cooling capacity is based on 27°CDB / 19°CWB (indoor temperature), 35°CDB (outdoor temperature).2. The above is the value for connecting with the following indoor units.- 2500, 3500W class: Wall Mounted Jungfrau Y Series [only for AQV**YWAN]3. Capacities are based on the following conditions:- Corresponding refrigerant piping length : 5m / - Level difference : 0m4. The total ability of connected a indoor unit is up to 6.0 kW (@ Cooling)5. It is impossible to connect the indoor unit for one room only.6. Power consumption include indoor unit power.Maldives P Series & DeluxeCOOLINGIndoor Unit Combination Cooling Capacity (W) Capacity Power Consumption CurrentHEATINGOutdoor UnitIndoor Unit Combination Heating Capacity (W) Capacity Power Consumption CurrentA B C D % Total A B C D TotalW W AMIN NOM MAX MIN NOM MAX MIN NOM MAXEEREGOutdoor Unit1 UnitA B C D % Total A B C D TotalW W AMIN NOM MAX MIN NOM MAX MIN NOM MAX2000 - - - 50% 2000 2100 - - - 2100 1250 2100 2520 300 540 630 1.7 2.5 2.9 3.89 A2500 - - - 63% 2500 2500 - - - 2500 1250 2500 3120 300 750 880 1.7 3.4 4.0 3.33 A3500 - - - 88% 3500 3500 - - - 3500 1250 3500 4200 300 1060 1240 1.7 4.9 5.7 3.30 AEEREG1 Unit2 Unit3200 - - - 73% 3200 3100 - - - 3100 1000 3100 3450 260 850 1080 1.3 3.9 4.9 3.65 A4000 - - - 91% 4000 3800 - - - 3800 1000 3800 4370 260 1100 1380 1.3 5.0 6.3 3.45 B3200 3200 - - 145% 6400 2200 2200 - - 4400 1000 4400 4700 280 1160 1400 1.4 5.3 6.4 3.79 A3200 4000 - - 164% 7200 1960 2440 - - 4400 1000 4400 4700 280 990 1400 1.4 4.5 6.4 4.44 A742012 SAMSUNGSystem Air Conditioner2 Unit2000 2000 - - 100% 4000 2000 2000 - - 4000 1250 4000 4500 300 1180 1330 1.7 5.4 6.1 3.39 A2000 2500 - - 113% 4500 1780 2220 - - 4000 1300 4000 4500 350 1180 1330 1.9 5.4 6.1 3.39 A2000 3500 - - 138% 5500 1450 2550 - - 4000 1300 4000 4500 350 1180 1330 1.9 5.4 6.1 3.39 A2500 2500 - - 125% 5000 2000 2000 - - 4000 1300 4000 4500 350 1180 1330 1.9 5.4 6.1 3.39 A2500 3500 - MAX 150% 6000 1670 2330 - - 4000 1300 4000 4500 350 1020 1330 1.9 4.7 6.1 3.92 A1. Cooling capacity is based on 27°CDB / 19°CWB (indoor temperature), 35°CDB (outdoor temperature).2. The above is the value for connecting with the following indoor units.- 2000, 2500, 3500W class: Wall Mounted Madives P Series, Maldives DELUXE [only for AQV**PSBN, AQV***PMEN, AQV***PMBN]3. Capacities are based on the following conditions:- Corresponding refrigerant piping length : 5m / - Level difference : 0m4. The total ability of connected a indoor unit is up to 6.0 kW (@ Cooling)5. It is impossible to connect the indoor unit for one room only.6. Power consumption include indoor unit power.1. Heating capacity is based on 20°CDB (indoor temperature), 7°CDB/6°CWB (outdoor temperature).2. The above is the value for connecting with the following indoor units.- 3200, 4000W class: Wall Mounted Jungfrau Y Series [only for AQV**YWAN]3. Capacities are based on the following conditions:- Corresponding refrigerant piping length : 5m / - Level difference : 0m4. The total ability of connected a indoor unit is up to 7.2 kW (@ Heating)5. It is impossible to connect the indoor unit for one room only.6. Power consumption include indoor unit power.752012 SAMSUNGSystem Air Conditioner