10.07.2015 Views

Specification - Klíma

Specification - Klíma

Specification - Klíma

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Capacity CombinationSystem80RJ052F3HXEAMaldives P Series & DeluxeCOOLINGOutdoor Unit1 Unit2 Unit3 UnitOutdoor Unit1 Unit2 Unit3 UnitIndoor Unit Combination Cooling Capacity (W) Capacity Power Consumption CurrentA B C D % Total A B C D TotalW W AMIN NOM MAX MIN NOM MAX MIN NOM MAX2000 - - - 38% 2000 2000 - - - 2000 1280 2000 2880 420 630 1020 2.2 2.9 4.7 3.17 B2500 - - - 48% 2500 2500 - - - 2500 1280 2500 3120 420 790 1110 2.2 3.6 5.1 3.16 B3500 - - - 67% 3500 3500 - - - 3500 1280 3500 4200 420 1150 1510 2.2 5.3 6.9 3.04 B5000 - - - 96% 5000 5000 - - - 5000 1300 5000 5800 420 1620 2090 2.2 7.4 9.6 3.09 B2000 2000 - - 77% 4000 2000 2000 - - 4000 1300 4000 4800 440 1240 1630 2.3 5.7 7.5 3.23 A2000 2500 - - 87% 4500 2040 2560 - - 4600 1300 4600 5520 440 1410 1850 2.3 6.5 8.5 3.26 A2000 3500 - - 106% 5500 1820 3180 - - 5000 1300 5000 6290 450 1520 2000 2.3 7.0 9.2 3.29 A2000 5000 - - 135% 7000 1490 3710 - - 5200 1380 5200 6600 450 1540 2040 2.3 7.0 9.3 3.38 A2500 2500 - - 96% 5000 2500 2500 - - 5000 1300 5000 5800 440 1550 1980 2.3 7.1 9.1 3.23 A2500 3500 - - 115% 6000 2080 2920 - - 5000 1300 5000 6400 450 1510 2020 2.3 6.9 9.2 3.31 A2500 5000 - - 144% 7500 1730 3470 - - 5200 1380 5200 6800 450 1540 2070 2.3 7.0 9.5 3.38 A3500 3500 - - 135% 7000 2600 2600 - - 5200 1300 5200 6560 450 1540 2040 2.3 7.0 9.3 3.38 A2000 2000 2000 - 115% 6000 1730 1730 1740 - 5200 1700 5200 6380 450 1500 2020 2.3 6.9 9.2 3.47 A2000 2000 2500 - 125% 6500 1600 1600 2000 - 5200 1700 5200 6490 450 1530 2040 2.3 7.0 9.3 3.40 A2000 2000 3500 - 144% 7500 1390 1390 2420 - 5200 1700 5200 6800 460 1420 2070 2.4 6.5 9.5 3.66 A2000 2500 2500 - 135% 7000 1480 1860 1860 - 5200 1700 5200 6600 450 1390 2040 2.3 6.4 9.3 3.74 A2000 2500 3500 - 154% 8000 1300 1630 2270 - 5200 1700 5200 6800 460 1420 2070 2.4 6.5 9.5 3.66 A2500 2500 2500 - 144% 7500 1730 1730 1740 - 5200 1700 5200 6800 460 1350 2070 2.4 6.2 9.5 3.85 A1. Cooling capacity is based on 27°CDB / 19°CWB (indoor temperature), 35°CDB (outdoor temperature).2. The above is the value for connecting with the following indoor units.- 2000, 2500, 3500, 5000W class: Wall Mounted Madives P Series, Maldives DELUXE [only for AQV**PSBN, AQV***PMEN, AQV***PMBN]3. Capacities are based on the following conditions:- Corresponding refrigerant piping length : 5m / - Level difference : 0m4. The total ability of connected a indoor unit is up to 8.0 kW (@ Cooling)5. It is impossible to connect the indoor unit for one room only.6. Power consumption include indoor unit power.HEATINGIndoor Unit Combination Heating Capacity (W) Capacity Power Consumption CurrentA B C D % Total A B C D TotalW W AMIN NOM MAX MIN NOM MAX MIN NOM MAX2200 35% 2200 2200 - - - 2200 1300 2200 2990 350 910 1110 1.9 4.2 5.1 2.42 F3300 52% 3300 3300 - - - 3300 1300 3300 3340 350 1150 1270 1.9 5.3 5.8 2.87 D4000 63% 4000 4000 - - - 4000 1300 4000 4370 350 1350 1660 1.9 6.2 7.6 2.96 D6000 95% 6000 5600 - - - 5600 1350 5600 6300 350 1820 1920 1.9 8.3 8.8 3.08 D2200 2200 - - 70% 4400 2200 2200 - - 4400 1400 4400 5060 350 1220 1510 1.9 5.6 6.9 3.61 A2200 3300 - - 87% 5500 2040 3060 - - 5100 1400 5100 5870 350 1410 1830 1.9 6.5 8.4 3.62 A2200 4000 - - 98% 6200 1990 3610 - - 5600 1400 5600 6440 350 1540 1860 1.9 7.0 8.5 3.64 A2200 6000 - - 130% 8200 1610 4390 - - 6000 1400 6000 6900 350 1660 1860 1.9 7.6 8.5 3.61 A3300 3300 - - 105% 6600 2900 2900 - - 5800 1400 5800 6300 350 1600 1910 1.9 7.3 8.7 3.63 A3300 4000 - - 116% 7300 2620 3180 - - 5800 1400 5800 6300 350 1600 1910 1.9 7.3 8.7 3.63 A3300 6000 - - 148% 9300 2240 4060 - - 6300 1400 6300 7300 350 1740 1830 1.9 8.0 8.4 3.62 A4000 4000 - - 127% 8000 2950 2950 - - 5900 1400 5900 6880 350 1630 1860 1.9 7.5 8.5 3.62 A2200 2200 2200 - 105% 6600 1930 1930 1940 - 5800 1400 5800 6760 350 1590 1840 1.9 7.3 8.4 3.65 A2200 2200 3300 - 122% 7700 1690 1690 2520 - 5900 1400 5900 6840 350 1650 1840 1.9 7.6 8.4 3.58 B2200 2200 4000 - 133% 8400 1650 1650 3000 - 6300 1400 6300 7300 350 1660 1830 1.9 7.6 8.4 3.80 A2200 3300 3300 - 140% 8800 1500 2250 2250 - 6000 1400 6000 6920 350 1590 1840 1.9 7.3 8.4 3.77 A2200 3300 4000 - 151% 9500 1460 2190 2650 - 6300 1400 6300 7300 350 1630 1830 1.9 7.5 8.4 3.87 A3300 3300 3300 - 157% 9900 2100 2100 2100 - 6300 1400 6300 7300 350 1400 1830 1.9 6.4 8.4 4.50 A1. Heating capacity is based on 20°CDB (indoor temperature), 7°CDB/6°CWB (outdoor temperature).2. The above is the value for connecting with the following indoor units.- 2200, 3300, 4000, 6000W class: Wall Mounted Madives P Series, Maldives DELUXE [only for AQV**PSBN, AQV***PMEN, AQV***PMBN]3. Capacities are based on the following conditions:- Corresponding refrigerant piping length : 5m / - Level difference : 0m4. The total ability of connected a indoor unit is up to 9.9 kW (@ Heating)5. It is impossible to connect the indoor unit for one room only.6. Power consumption include indoor unit power.EEREEREGEGJungfrau Y-seriesCOOLINGOutdoor Unit1 UnitIndoor Unit Combination Cooling Capacity (W) Capacity Power Consumption CurrentA B C D % Total A B C D TotalW W AMIN NOM MAX MIN NOM MAX MIN NOM MAX2500 - - - 48% 2500 2500 - - - 2500 1280 2500 3120 420 790 1110 2.2 3.6 5.1 3.16 B3500 - - - 67% 3500 3500 - - - 3500 1280 3500 4200 420 1150 1510 2.2 5.3 6.9 3.04 B5000 - - - 96% 5000 4900 - - - 4900 1300 4900 5500 420 1620 2090 2.2 7.4 9.6 3.09 B2500 2500 - - 96% 5000 2500 2500 - - 5000 1300 5000 5800 440 1550 1980 2.3 7.1 9.1 3.23 A2 Unit2500 3500 - - 115% 6000 2080 2920 - - 5000 1300 5000 6400 450 1510 2020 2.3 6.9 9.2 3.31 A2500 5000 - - 144% 7500 1730 3470 - - 5200 1380 5200 6800 450 1540 2070 2.3 7.0 9.5 3.38 A3500 3500 - - 135% 7000 2600 2600 - - 5200 1300 5200 6560 450 1540 2040 2.3 7.0 9.3 3.38 A3 Unit 2500 2500 2500 - 144% 7500 1730 1730 1740 - 5200 1700 5200 6800 460 1350 2070 2.4 6.2 9.5 3.85 A1. Cooling capacity is based on 27°CDB / 19°CWB (indoor temperature), 35°CDB (outdoor temperature).2. The above is the value for connecting with the following indoor units.- 2500, 3500, 5000W class: Wall Mounted Jungfrau Y Series [only for AQV**YWAN]3. Capacities are based on the following conditions:- Corresponding refrigerant piping length : 5m / - Level difference : 0m4. The total ability of connected a indoor unit is up to 7.5 kW (@ Cooling)5. It is impossible to connect the indoor unit for one room only.6. Power consumption include indoor unit power.HEATINGOutdoor Unit1 UnitIndoor Unit Combination Heating Capacity (W) Capacity Power Consumption CurrentA B C D % Total A B C D TotalW W AMIN NOM MAX MIN NOM MAX MIN NOM MAX3200 - - - 51% 3200 3300 - - - 3300 1300 3300 3340 350 1150 1270 1.9 5.3 5.8 2.87 D4000 - - - 63% 4000 4000 - - - 4000 1300 4000 4370 350 1350 1660 1.9 6.2 7.6 2.96 D6000 - - - 95% 6000 5500 - - - 5500 1350 5500 6300 350 1820 1920 1.9 8.3 8.8 3.08 D3200 3200 - - 102% 6400 2900 2900 - - 5800 1400 5800 6300 350 1600 1910 1.9 7.3 8.7 3.63 A2 Unit3200 4000 - - 114% 7200 2580 3220 - - 5800 1400 5800 6300 350 1600 1910 1.9 7.3 8.7 3.63 A3200 6000 - - 146% 9200 2190 4110 - - 6300 1400 6300 7300 350 1740 1830 1.9 8.0 8.4 3.62 A4000 4000 - - 127% 8000 2950 2950 - - 5900 1400 5900 6880 350 1630 1860 1.9 7.5 8.5 3.62 A3 Unit 3200 3200 3200 - 152% 9600 2100 2100 2100 - 6300 1400 6300 7300 350 1400 1830 1.9 6.4 8.4 4.50 A1. Heating capacity is based on 20°CDB (indoor temperature), 7°CDB/6°CWB (outdoor temperature).2. The above is the value for connecting with the following indoor units.- 3200, 4000, 6000W class: Wall Mounted Jungfrau Y Series [only for AQV**YWAN]3. Capacities are based on the following conditions:- Corresponding refrigerant piping length : 5m / - Level difference : 0m4. The total ability of connected a indoor unit is up to 9.6 kW (@ Heating)5. It is impossible to connect the indoor unit for one room only.6. Power consumption include indoor unit power.EEREEREGEGSystem 812012 SAMSUNGSystem Air Conditioner2012 SAMSUNGSystem Air Conditioner

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!