Eco Heating SystemEHSLineup & Feature - Mono Type ( A2W )Type 9.0kW 12kW 14kWOutdoor UnitType 200L 300LEHS <strong>Specification</strong> - Split Type ( A2W & A2A )Outdoor Unit(GEN2, Split Type)Eco Heating SystemCylinder Unit(Standard / Solar Connected)• One outdoor unit gets done the task that two outdoor units used to do- Air-to-Water (A2W) and Air-to-Air (A2A)TypeMIM-E03AModel RD060PHXEA RD070PHXEA RD080PHXEAControl UnitMode -Heat Pump(A2A/A2W Multi)Heat Pump(A2A/A2W Multi)Heat Pump(A2A/A2W Multi)Power Supply V, Hz 1, 2, 220~240, 50 1, 2, 220~240, 50 1, 2, 220~240, 50Performance(A2W #1)NominalCapacity *1)HeatingCoolingW 6,000 7,000 8,000Btu/h 20,500 23,900 27,300W 7,000 7,500 8,000Btu/h 23,900 25,600 27,300PowerNominalInput *1)Heating W 1,305 1,590 1,925Cooling W 1,945 2,205 2,540EnergyNominal Heating (COP) *1) W/W 4.60 4.40 4.15Nominal Cooling (EER) *1) W/W 3.60 3.40 3.15 wESEER *2) W/W 5.20 5.50 4.90Performance(A2W #2)NominalCapacity *3)HeatingCoolingW 5,300 6,200 7,200Btu/h 18,100 21,200 24,600W 5,000 5,300 5,800Btu/h 17,100 18,100 19,800PowerNominalInput *3)Heating W 1,555 1,875 2,250Cooling W 1,850 2,040 2,320EnergyNominal Heating (COP) *3) W/W 3.40 3.30 3.20Nominal Cooling (EER) *3) W/W 2.70 2.60 2.50ESEER *4) W/W 3.60 3.70 3.70Performance(A2A)NominalW 3,000~6,000 3,500~7,000 4,000~8,000CoolingCapacityBtu/h 10,200~20,500 11,900~23,900 13,600~27,300Allowable No. of Indoor Units EA Max 3 Max 3 Max 3EnergyNominal Heating (COP) *5) W/W 4.04 4.04 4.04Nominal Cooling (EER) *5) W/W 3.21 3.21 3.21SoundPipingConnectionsSoundPressure *6)Ref. PipeInstallationLimitationHeating dB(A) 48 48 49Cooling dB(A) 48 48 50LiquidGasmm(inch)mm(inch)9.52(3/8") 9.52(3/8") 9.52(3/8")15.88(5/8") 15.88(5/8") 15.88(5/8")Length m 30 30 30Height m 15 15 15ExternalDimensionWeightDimensions(WxHxD)Net kg 71 71 71Gross kg 79 79 79Net mm 880x798x310 880x798x310 880x798x310Gross mm 1,023x891x413 1,023x891x413 1,023x891x413140OperatingRangeAmbient(A2W)Ambient(A2A)Heating °C -20~35 -20~35 -20~35Cooling °C 10~46 10~46 10~46DHW °C -20~43 -20~43 -20~43Heating °C -20~24 -20~24 -20~24Cooling °C 10~43 10~43 10~431412012 SAMSUNGSystem Air Conditioner*1)~*4) A2W rating conditions in accordance with Eurovent Rating Standard for Liquid Chilling Packages 6/C/003-2008.*1) A2W Condition #1 : (Heating) Water In/Out 30°C/35°C, Outdoor Air DB/WB 7°C/6°C; (Cooling) Water In/Out 23°C/18°C, Outdoor Air DB 35°C.*2) A2W Condition for ESEER(Cooling) at Water Out 18°C.*3) A2W Condition #2 : (Heating) Water In/Out 40°C/45°C, Outdoor Air DB/WB 7°C/6°C; (Cooling) Water In/Out 12°C/7°C, Outdoor Air DB 35°C.*4) A2W Condition for ESEER(Cooling) at Water Out 7°C.*5) A2A Condition : (Heating) Indoor Air DB/WB 20°C/15°C, Outdoor Air DB/WB 7°C/6°C; (Cooling) Indoor Air DB/WB 27°C/19°C, Outdoor Air DB/WB 35°C/24°C.*6) Sound Pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.2012 SAMSUNGSystem Air Conditioner
Eco Heating SystemEHS <strong>Specification</strong> - Split Type ( A2W & A2A )Outdoor Unit(GEN2, Splite Type)Hydro Unit• Multi Functional controller for delicate controlEco Heating System• One outdoor unit gets done the task that two outdoor units used to do- Air-to-Water (A2W) and Air-to-Air (A2A)Model RD110PHXEA RD140PHXEA RD160PHXEAModel NH080PHXEA NH160PHXEAMode -Heat Pump(A2A/A2W Multi)Heat Pump(A2A/A2W Multi)Heat Pump(A2A/A2W Multi)Power Supply V, Hz 1, 2, 220~240, 50 1, 2, 220~240, 50 1, 2, 220~240, 50Performance(A2W #1)PowerEnergyPerformance(A2W #2)PowerEnergyPerformance(A2A)EnergyNominalCapacity *1)NominalInput *1)HeatingCoolingW 11,000 14,000 16,000Btu/h 37,500 47,800 54,600W 11,300 14,200 15,500Btu/h 38,600 48,500 52,900Heating W 2,420 3,210 3,900Cooling W 2,900 3,940 4,700Nominal Heating (COP) *1) W/W 4.55 4.36 4.10Nominal Cooling (EER) *1) W/W 3.90 3.60 3.30ESEER *2) W/W 5.96 5.66 5.50NominalCapacity *3)NominalInput *3)HeatingCoolingW 10,000 12,900 14,500Btu/h 34,100 44,000 49,500W 8,500 10,200 10,700Btu/h 29,000 34,800 36,500Heating W 2,860 3,850 4,530Cooling W 2,700 3,520 4,040Nominal Heating (COP) *3) W/W 3.50 3.35 3.20Nominal Cooling (EER) *3) W/W 3.15 2.90 2.65ESEER *4) W/W 4.91 4.82 4.29NominalW 6,000~11,000 6,400~14,000 6,400~14,000CoolingCapacityBtu/h 20,500~37,500 21,80w0~47,800 21,800~47,800Allowable No. of Indoor Units EA Max 4 Max 4 Max 4Nominal Heating (COP) *5) W/W 3.94 3.94 3.94Nominal Cooling (EER) *5) W/W 3.46 3.46 3.46Power Supply V, Hz 1, 2, 220~240, 50 1, 2, 220~240, 50Normal CapacityLeaving WaterTemperature RangeDimension(WxHxD)Heating W 6,000 / 7,000 / 8,000 11,000 / 14,000 / 16,000Cooling W 7,000 / 7,500 / 8,000 11,300 / 14,200 / 15,500Heating ºC 15~55 (H/P : 25~55) 15~55 (H/P : 25~55)Cooling ºC 5~25 5~25Net mm 510x850x315 510x850x315Gross mm 564x1,024x412 564x1,024x412WeightNet kg 45 48Gross kg 55 58Liquid , mm(inch) 9.52 (3/8”) 9.52 (3/8”)PipingGas , mm(inch) 15.88 (5/8”) 15.88 (5/8”)ConnectionsInlet inch BSPP male 1 1/4” BSPP male 1 1/4”Outlet inch BSPP male 1 1/4” BSPP male 1 1/4”Water Pump Flow Rate kg/min 17.0 / 20.5 / 23.0 31.5 / 40.1 / 45.9Electric Heater Input Power W 4,000 6,000Expansion Vessel Volume Liter 8.0 8.0Pressure Relief Valve Relief Pressure bar 2.9 2.9Air Purge Valve Size inch BSPP male 3/8” BSPP male 3/8”Service Valve Size inch BSPP male 1 1/4” BSPP male 1 1/4”Back up Boiler - 230VAC 1A(DO) 230VAC 1A(DO)Room Thermostat - 230VAC 1A(DI) 230VAC 1A(DI)External ControlSolar Pump - 230VAC 1A(DI) 230VAC 1A(DI)Valves, 2 or 3way - 230VAC 1A(DO) 230VAC 1A(DO)* Product <strong>Specification</strong>s in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.SoundPipingConnectionsSoundPressure *6)Ref. PipeInstallationLimitationHeating dB(A) 49 51 53Cooling dB(A) 50 52 54LiquidGasmm(inch)mm(inch)9.52(3/8") 9.52(3/8") 9.52(3/8")15.88(5/8") 15.88(5/8") 15.88(5/8")Length m 70 70 70Height m 30 30 30ExternalDimensionWeightDimensions(WxHxD)Net kg 108 108 108Gross kg 116 116 116Net mm 932x1,128x375 932x1,128x375 932x1,128x375Gross mm 1,091x1,286x472 1,091x1,286x472 1,091x1,286x472142OperatingRangeAmbient(A2W)Ambient(A2A)"Heating °C -20~35 -20~35 -20~35Cooling °C 10~46 10~46 10~46DHW °C -20~43 -20~43 -20~43Heating °C -20~24 -20~24 -20~24Cooling °C 10~43 10~43 10~431432012 SAMSUNGSystem Air Conditioner*1)~*4) A2W rating conditions in accordance with Eurovent Rating Standard for Liquid Chilling Packages 6/C/003-2008.*1) A2W Condition #1 : (Heating) Water In/Out 30°C/35°C, Outdoor Air DB/WB 7°C/6°C; (Cooling) Water In/Out 23°C/18°C, Outdoor Air DB 35°C.*2) A2W Condition for ESEER(Cooling) at Water Out 18°C.*3) A2W Condition #2 : (Heating) Water In/Out 40°C/45°C, Outdoor Air DB/WB 7°C/6°C; (Cooling) Water In/Out 12°C/7°C, Outdoor Air DB 35°C.*4) A2W Condition for ESEER(Cooling) at Water Out 7°C.*5) A2A Condition : (Heating) Indoor Air DB/WB 20°C/15°C, Outdoor Air DB/WB 7°C/6°C; (Cooling) Indoor Air DB/WB 27°C/19°C, Outdoor Air DB/WB 35°C/24°C.*6) Sound Pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.2012 SAMSUNGSystem Air Conditioner