10.07.2015 Views

Multi-functional electric energy meters - Circutor

Multi-functional electric energy meters - Circutor

Multi-functional electric energy meters - Circutor

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong><strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT is a family of combined multi-<strong>functional</strong><strong>meters</strong> that can meet anyrequirement of an <strong>energy</strong> metering system,including important aspects, suchas quality, accuracy, safety and reliability.The new metering technologies haveallowed CIRCUTOR to develop newstate-of-the-art equipment, includingadditional functions for the control andmanagement of metering systems, forexample, astronomical clocks, controlof the maximum demand, control of programmablepower, multi-supply meter(water and gas), <strong>meters</strong> with photovoltaicapplications (two-directional), communicationswith PLC systems, etc.Q.1The CIRWATT family offers a full rangeof <strong>electric</strong>al <strong>energy</strong> <strong>meters</strong> that areadapted to the type of application. It hasthe following sub-families:DefinitionIn general, <strong>electric</strong>al consumption <strong>meters</strong>are devices that meter the consumptionof <strong>electric</strong>al <strong>energy</strong> in a circuit or <strong>electric</strong>ityservice. The market offers electromechanicaland electronic <strong>meters</strong>. Electromechanical<strong>meters</strong> use parasitic currentand voltage in a disc, influenced by themagnetic fields produced by the turningmovement of the needles on a face.Electronic <strong>meters</strong> use a digital meteringmechanism.Q1-3


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>Product selection tableEquipmentActive / ReactiveEnergy ClassDirect / IndirectmeteringVoltageCurrentCOM1CommunicationsCOM2CommunicationsLoad curve 1Load curve 2EventsClosingInputs /Outputs ***PageCIRWATT A1 / -SingleDirect230 V127 V10(120) A10(60) APLC -1 month(60 min)**- - 1 • 7CIRWATTB IIB / 2SingleDirect230 V 10(60) A PLC -3 months(60 min)- 512 1 • 9CIRWATTB IIIThree-PhaseDirect /Indirec5(10) A10(100) APLC3 months(60 min)- 512 1 • 11CIRWATT C1 / 2Three-PhaseDirect /Indirect3x57/100 V···3x230/400 V5(10) A10(100) APLCRS-232RS-232RS-485-RS-485EthernetRS-485213 days(60 min)53 days(15 min)512 64 • 15CIRWATT D0,23 / 0,50,55 / 1Three-PhaseIndirect3x57/100 V···3x63.5/110V*1(2) A5(10) ARS-232RS-485Ethernet213 days(60 min)53 days(15 min)512 64 • 18PLC-800- -3x230/400 V···3x127/220 V- PLCEthernetGSMGPRS• - • • - 21(*) For other voltages, please ask(**) Only models with PLC(***) See specific catalogueSELECTION TABLE - Single-phase Energy MetersCIRWATT - - x -TYPE METER TB TA2 wires, asymmetrical connection • • 2Class 1 Active • 10Class B Active / Class 2.0 Reactive • 121 x 127 V c.a. • B1 x 230 V c.a. • E5 (60) S210 (120) S310 (60) • S450 Hz • A60 Hz • BConnectionmodeAccuracyMeasuredvoltageCurrentMeasurementFrequencyWithout communication • 0RS-485 • 2R1 / R2 (PLC) PLC A 4CommunicationsR1 / R2 (PLC) PLC B 5Without card 02 rrelays 5A 250V (tarif indicator) • 3impulse meter input • Atype B • Btype A • AImport only (2 Quadrants) • 0Bidirectional (4 Quadrants) • 1Unidirectional (4 Quadrants) 2ExpansionTypeRegistrationmodeCut off relay (phase) • • 2 More featuresQ1-5


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>SELECTION TABLE - Three-phase Energy MetersCIRWATT - - x -TYPE METER TB III TC TD4 wires • • • 40.2S active class / 0.5 Reactive class • 020.5S active class/ 1.0 Reactive class • 05C Active class / 1.0 Reactive class 05B Active class / 2.0 Reactive class • 103 x 57 / 100 V a.c. (4w) • L3 x 63.5 / 110 V a.c. (4w) • • M3 x 127 / 220 V a.c. • • N3 x 220 / 380 V a.c. • O3 x 230 / 400 V a.c. (4w) • • Q3 x 127 / 220 V a.c....3x230/400 Va.c. • • U5 (10) A Transformer • • • T510 (100) A Direct • • D150 Hz • • A60 Hz • • BAutomatic (50 / 60 Hz) • CConnectionmodeAccuracyMeasuredvoltageCurrent measureFrequencyWithout communications • 0R1 / R2 (PLC) RS232 / -R1 / R2 (PLC) RS485 / -R1 / R2 (PLC) Ethernet / -R1 / R2 (PLC)R1 / R2 (PLC)R1 / R2 (PLC)R1 / R2 (PLC)R1 / R2 (PLC)R1 / R2 (PLC)R1 / R2 (PLC)R1 / R2 (PLC)RS232/ - (PLC A)RS232/ - (PLC B)RS232 /RS232RS485 /RS485RS232 /RS485RS232 /Ether.RS232/USBRS485 /Ether.RS232 /RS232RS232 /RS485RS232 /Ether.PLC A 4PLC B 5RS232 /RS232RS485 /RS485RS232 /RS485RS232 /Ether.Without card • 0Inputs / outputs (optomos) ● ● ● 4inputs / outputs (relay) ● ● ● 5Inputs (water and gas) ● AEarth leakage measure ● B123789ACDCommunicationsExpansionmodulestype B meter • Btype C meter • CTypetype D meter • DImport only (2 Quadrants) • • 0Bidirectional (4 Quadrants) • • • 1Unidirectional (4 Quadrants) • 2Without more features • • • 0Cutoff relay • 2RegistrationmodeMore featuresQ1-6


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT ASingle-phase active <strong>energy</strong> meter, Class 1DescriptionCIRWATT A is a single-phase, digital multifunctionmeter, Class 1, for the metering ofactive <strong>energy</strong>.CIRWATT A complies with the existing regulationsapplicable to electronic <strong>meters</strong> and ithas an autonomous data retention systemthat avoids them from being lost when thereis an interruption in the power supply. Likewise,it can be read through the screen (evenwhen there is no power supply) and throughthe optical port (protocol IEC-61107).ApplicationIt has been specially designed for installationswhere electromechanical <strong>meters</strong> do notsatisfy the current needs, particularly thosethat require a single-phase meter with a billingsystem.FeaturesPower supplyBatteryNominal voltage 127 V or 230 V (depending on the type) Type LithiumTolerance 80 %... 120 % U nWorking life > 10 yearsConsumption < 0,4 W ClockFrequency 50 / 60 Hz Type Grid frequency quartz oscillatorOperating range - 20 ... + 60 ºC Drift < 0.5 s/day at 25 ºCMeasured voltageRelay outputsConnection Asymmetrical Type Mechanical relay ; 230 V - 10 AReference voltages 127 V or 230 V (depending on the type) LED outputsFrequency 50 / 60 Hz Maximum rate 1000 pulses / kW·hMeasured currentSecurityCategory III (110 V) inaccordance with EN-61010Currents (In) 5 (60) A, 10 (60) A, 10 (120) A Build featuresAccuracy Enclosure In compliance with DIN 43859Active <strong>energy</strong> Class 1.0 (IEC 62053-21) Dimensions In compliance with DIN 43857Calculation and processing Degree of protection IP 51Microprocessor Based on DSP Optical reader IEC-61107 for local accessConverter 16 bits EventsMemoryInverse consumption detectionData RAM type, stored by Lithium battery Total inverse <strong>energy</strong>Setup and events Non-volatile memory of the FLASH type Operating hoursTerminal cover opening detectionQ1-7


6<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT B100Single-phase <strong>energy</strong> meterFeaturesOptical portData configurationTypeSerial, bi-directionalMemory typeFIFOProtocolIEC 62056-21 Mode CTariffsSingle tariffConstruction featuresIP degree (IEC 60529) IP 54External dimensions DIN 43857Enclosing features DIN 43859Front / Base fixationSealed with ultra-soundsConnectionDIN Connection (Asymmetrical)BS Connection (Symmetrical)PNNETWORKLOADPNPNNETWORKLOADPNDimensionsn8.518 23 1812.5246R4509n13R3009310593125 43.92Q1-10


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT B 101CIRWATT B 102Single-phase <strong>energy</strong> meterDescriptionCIRWATT B 101-102 are single phase residential <strong>meters</strong> with class B(class 1) in active <strong>energy</strong> and class 2 in reactive <strong>energy</strong>. It has 4 tariffsand a flexible configuration. An advanced design offers high features andversatility to fulfill requirements in domestic applications.These <strong>meters</strong> have memory to record load profile for 400 days, 12 billingclosures and moreover tamper registers and power quality information.As an option it has a backlight display to help in reading <strong>energy</strong> consumptionsor any other information showed if there is no enough light.ApplicationUsing an RS-485 communication port it is possible to connect upto 32 <strong>meters</strong> in the same bus and download data remotely using aGSM/GPRS modem.These <strong>meters</strong> have many options to detect tampering or any unauthorizedaccess to the meter such as: magnetic field detection, reverse currentdetection, terminal cover removed, neutral current measurement.Using CIRWATT B 101-102 pulse output, user can add a CIRCU-TOR impulse concentrator LM, which allows to centralize <strong>energy</strong>consumptions and send all data remotely to an <strong>energy</strong> managementsoftware Power Studio.FeaturesPower supplyNominal voltageToleranceConsumptionFrequencyVoltage measurementConnectionReference voltageFrequencyCurrent measurementNominal reference current (I ref)Maximum current (I max)Minimal current (I min)Starting current (I st)Accuracy class127 V or 230 V80%...115% U n 20 years @ 30 ºCEnvironmental influenceOperating temperature range 40 ºC ... +70 ºCStorage temperature -40 ºC ... +85 ºCHumidity95% max.IsolationInsultation voltage4 kV a 50 Hz durante un minutoImpulse voltage 1.2/50us - IEC 62052-116 kVProtection degree (IEC 62052-11) IIDisplayTypeLCDNumber of data digits Up to 7Read without supplyYesBacklightYes (optional)Q1-11


9<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>FeaturesOptical portData configurationTypeSerial, bi-direccionalMemory typeFIFOProtocolIEC 62056-21 Mode CTariffs Up to 4Communication port RS-485 (in model 102)Billing clousures 15TypeSerial, bi-direccionalLoad profileYes (optional)ProtocolIEC 62056-21 Mode C / MODBUSRegisters for load profile 9600Constrution featuresIP Degree (IEC 60529) IP 53External dimmensions DIN 43857Enclosing features DIN 43859Anti-tampering featuresTerminal cover detectionReverse wiring detectionCurrent measurementManipulation registerYes (micro-switch)YesYes (optional)Yes, up to 200 registersFeaturesConnectionsCommunication port RS-485CIRWATT B 101 CIRWATT B 102•2122 Available optionsRS-485 Communications23 24 Available optionsS0Pulse output (IEC 62053-31) • •Tariff relayInput for tariff control(Ripple control)• •Relay output for tariff indication • •21222324T1-2RCRElectromagnetic field detection • •LNETWORKNLOADLNDimensions129 6662151558105Q1-12


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>ELECTRICITY DISPENSER B IISingle phase <strong>energy</strong> meter with dispenser functionand circuit breaker.DescriptionThe ELECTRICITY DISPENSER B II is a single-phase meter with an<strong>electric</strong> <strong>energy</strong> dispensing function to control the demand.The <strong>energy</strong> dispenser function is based on the patented concept ofthe daily <strong>energy</strong> allowance, allowing the user a smart managementof the available <strong>electric</strong>ity in grids with limited or pulsating generation,such as those fed with renewable <strong>energy</strong> sources.It includes a main switch that works as a maximum power and maximumdemand control as well as an auxiliary switch that can be usedfor connection or disconnection of non-essential consumptions.The <strong>energy</strong> meter complies with the European regulations (MID) EN50470-1 and EN50470-3, being class B for active <strong>energy</strong> measuringand class 2 for reactive <strong>energy</strong> measuring.It has a standard optical port and a communications port for networkconnection used for the writing/reading of para<strong>meters</strong> and for datalogging.It incorporates a wireless RFID card reader were the configurationpara<strong>meters</strong>, according to the grid where it will be connected, are included,and also used as a contract and billing control.The LCD screen and LEDs enable the user to check the <strong>energy</strong> availability.Application}}Rural Micro-grids with renewable energies such as solar, wind, hydroand others…}}Micro-grids with diesel generators where it is needed to limit theavailable <strong>energy</strong>.}}Control of the daily <strong>energy</strong> allowance in stand-alone installations}}Electric <strong>energy</strong> meter with flat tariff or prepaid RFID card for difficultaccess consumptions and / or low consumptionsFeaturesPower supplyNominal voltage230 V or 120 VTolerance80 % ... 115 % U nConsumption


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>ELECTRICITY DISPENSER B IISingle phase <strong>energy</strong> meter with dispenser function and circuit breaker.FeaturesBatteryTypeLithiumWorking Life >10 years at 30ºCClockTypeGregorian calendarSourceTemperature compensated oscillatorAccuracy (EN61038)< 0.5 s/dayEnvironmental influenceOperating temperature range -25ºC to +70ºCStorage temperature range-40ºC to +85ºCTemperature coefficient< 15 ppm/KHumidity95 % max.InsulationInsulating voltage4 kV to 50 Hz during 1 minImpulse voltage 1.2/50µs - IEC 62052-118 kVProtection degree (IEC 62052-11) IIDisplayTypeLCDNumber of data digits UP to 6Size of data digits9 mmDisplay data reading whenthere is no voltageYesOptical communications interfaceTypeFull duplexHardware IEC 62056-21ProtocolModbusRS-485 communication channelTypeHalf duplexConfiguration 9600, 8, n, 1ProtocolModbusRFIDTechnology Mifare MF1 ICS 50RelayNominal current40 AMaximum current120 A / 5 minutesAuxiliary relayNominal current5 A at 230VcaTampering detectionDetectionOpening the terminal coverTypeMicro-switchFunctionDetects intruders whenthere is no voltageConstruction featuresConnectionAsymmetricalExternal dimensions DIN 43857Enclosing features DIN 43859IP Degree (IEC 60529) IP 51ConnectionsDimensions62 12923 2413 4 6215LMAIN REDNLCARGA LOADNQ1-14


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT B 200Single-phase active <strong>energy</strong> meter, Class B* andreactive, Class 2DescriptionCIRWATT B is a multi-function digital single-phase meter, Class B in active<strong>energy</strong> and Class 2 in reactive <strong>energy</strong>. The meter complies with Europeanlegislation related to <strong>energy</strong> <strong>meters</strong> (MID) EN 50470-1 and EN50470-3, which approves the installation of these <strong>meters</strong> in any countryof the European Union.It includes PLC (Power Line Carrier) Communications through powercable and an optical communications port. Both use IEC-61870-5-102protocol. In addition, it can display information in case of power lossjust pressing the button, it can store up to 6 channels of <strong>energy</strong> registerswith 3 months of hourly load profile and it can limit maximumpower consumed by end-user, through an internal disconnection relaywhich can be remotely managed using PLC communications.ApplicationThe main application of the CIRWATT B meter is the metering of activeand reactive <strong>energy</strong> for billing purposes, whenever a meter with highperformance features is required at an optimised cost. PLC communicationscan be used for the remote download of all data recorded bythe meter through a PLC-800 concentrator.The circuit breaker integrated in the meter can be used to manage thesupply remotely, opening/closing the circuit breaker and programmingthe hired power above a value that will activate the circuit breaker, openingit and reclosing it to guarantee the safety for the final user.FeaturesPower supplyBatteryNominal voltage 230 V Type LithiumTolerance 80 % ... 115 % U nWorking Life >20 years @ 30ºCConsumption


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT BSingle-phase active <strong>energy</strong> meter, Class B and reactive, Class 2FeaturesOptical communications interfaceRate programmingType Serial, two-directional Number of days 4Hardware IEC 62056-21 Types of days 4Protocol REE, based on IEC 870-5-102 Contracts 1Tampering detector Number of Tariffs 6Detection Opening the terminal cover Discrimination 1 hourType Micro-switch Holidays/festivities 15FunctionDetects intruders whenthere is no voltage.Special daysNoneConstruction featuresLoad curveConnection Asymmetrical NUmber of load curves 1External dimensions DIN 43857 Integration time Programmable: 1 ... 253Enclosing features DIN 43859 Recording depth 2200IP Degree (IEC 60529) IP 51 EventsPLC Number of events 200Modulation system DSCK with repeater system Billing closuresHardware CENELEC A or CENELEC B Number of locks 12, per contractProtocolCirPLC and PEP (PLCEncapsulated Protocol)TypeDisabled / Programmabledate and hourReferencesMetering voltage230 VacCurrent meteringrange (A)Hourly discriminationQuadrantsRelay outputsImpulse outputsImpulse inputsCommunicationInternal Circuitbreaker• 10 (60) DH 1 4 2 PLC A • CIRWATT B - 212-ES4-43B-12• 10 (60) DH 0 4 2 PLC A • CIRWATT B - 212-ED4-43B-12TypeConnectionsDimensions62 12923 2413 4 6215LNREDLCARGANQ1-16


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT B 410DStandard three-phase meter with direct connectionDescriptionFeaturesCIRCUTOR’s CIRWATT B 410D is a standardthree phase direct connection meter,as a result of all the technological developmentswhich is experiencing the currentmarket. These changes have created newneeds and requirements both in terms ofmore flexible rates, new communicationssystems and a price optimization.ApplicationPower supplyNominal voltage3 x 230 (400) V - 3 x 127 (230) VTolerance80% ... 115% U nConsumption< 2 W; < 10 V·AFrequency50 or 60 HzVoltage measurementConnectionAsymmetricalReference voltage 3 x 230 (400) V - 3 x 127 (230) V *Frequency50 or 60 HzVoltage consumption of the circuit< 2 W; 10 V·ACurrent measuramentNominal reference current l ref(l max) 5 (100) A or 10 (100) A or 10 (120) A or 15 (120) A *Start-up current l st< 0,04 x I trCIRWATT B 410D is suitable for LV applications(with currents from 100 to 120 A),adapted to new market challenges, havingdifferent communication systems and expansionmodules. Providing to the market arobust and competitive meter fully complyingwith the new European Directive MID(EN 50470) and all the relevant IEC’s.Minimum current l min< 0,5 x I trCurrent consumption of the circuit< 0,1 V·AAccuracy classAccuracy measured in active <strong>energy</strong> EN 50470 (Class B) - IEC 62053-21 (Class 1)Accuracy measured in reactive <strong>energy</strong> IEC 62053-23 (Class 2)MemoryDataNon-volatile memorySetup and eventsSerial flashBatteryTypeLithiumWorking Life > 20 years @ 30 ºCClockTypeGregorian calendarSourceTemperature compensated oscillatorAccuracy (EN 61038) < 0.5 s / day at 23 ºCEnvironmental influenceOperating temperature range -40 ... +70 ºCStorage temperature range -40 ... +85 ºCTemperature coefficient< 15 ppm/KHumidity95 % máx.InsulationInsulating voltage4 kV a 50 Hz during 1 minImpulse voltage 1.2/50 µs - IEC 62052-11 8 kVProtection degree (IEC 62052-11)IIDisplayTypeLCDNumber of data digits up to 8Size of data digits8 mmDisplay data reading whenthere is no voltage.Yes* Request for other configurationsQ1-17


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT B 410DStandard three-phase meter with direct connectionFeaturesOptical communications interfaceRate programmingType Serial, two-directional Number of days 12Hardware IEC 62056-21 Types of days 10Protocol REE, based on IEC 870-5-102 Contracts 3Tampering detector Number of Tariffs 9Detection Opening the terminal cover Discrimination 1 hourType Micro-switch Holidays/festivities 30FunctionConstruction featuresDetects intruders whenthere is no voltage.Special days 12Load curveConnection Asymmetrical Number of load curves 2External dimensions DIN 43857 Integration time Programmable: 1 ... 253 minEnclosing features DIN 43859 Recording depth 4000IP Degree (IEC 60529) IP 51 EventsPLC Number of events 200Modulation system DSCK with repeater system Billing closuresHardware CENELEC A or CENELEC B Number of locks 12, per contractProtocolCirPLC and PEP (PLCEncapsulated Protocol)TypeDisabled / Programmabledate and hourOther featuresConnectionsCommunications * Expansion cards *RS-232 / PLCWithout inputs / outputsCIRWATT B 410D three-fase direct connectionRS-485 / PLCRS-232 / RS-2324 relay otuputs (Tariff indicator)2 relay outputs / 4 impulse inputs125 83 4 6 7 9 10 12RS-485 / RS-4854 pulse inputsRS-232 / RS-485Earth leakage measurementRS-232 / EthernetR-485 / Ethernet* Request for other configurations2 relay outputs / 2 impulse outputs /2 impulse inputsL1L2L3NDimensionsTerminal cover optionWire cover option6676116711172172205,5255661851,21506717215017267Q1-18


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT B 410DStandard three-phase meter with direct connectionReferencesClass (Active/Reactive)QuadrantsFrequency (Hz)Measuring range VMeasuring range ACommunicationCOM1CommunicationCOM2TypeCodeB / 2 4 50 or 60 Hz 3x230/400 V 10 (100)A RS-232 RS232 CIRWATT B 410-QD1A-70B10 QB4A0B / 2 4 50 or 60 Hz 3x230/400 V 10 (100)A RS-485 RS485 CIRWATT B 410-QD1A-80B10 QB4E0B / 2 4 50 or 60 Hz 3x230/400 V 10 (100)A RS-232 RS485 CIRWATT B 410-QD1A-90B10 QB4B0B / 2 4 50 or 60 Hz 3x230/400 V 10 (100)A RS-232 ETHERNET CIRWATT B 410-QD1A-A0B10 QB4C0B / 2 4 50 or 60 Hz 3x230/400 V 10 (100)A RS-485 ETHERNET CIRWATT B 410-QD1A-D0B10 QB4D0B / 2 4 50 or 60 Hz 3x127/220 V 10 (100)A RS-232 RS232 CIRWATT B 410-ND1A-70B10 QB740B / 2 4 50 or 60 Hz 3x127/220 V 10 (100)A RS-485 RS485 CIRWATT B 410-ND1A-80B10 QB7E0B / 2 4 50 or 60 Hz 3x127/220 V 10 (100)A RS-232 RS485 CIRWATT B 410-ND1A-90B10 QB7B0B / 2 4 50 or 60 Hz 3x127/220 V 10 (100)A RS-232 ETHERNET CIRWATT B 410-ND1A-A0B10 QB7C0B / 2 4 50 or 60 Hz 3x127/220 V 10 (100)A RS-485 ETHERNET CIRWATT B 410-ND1A-D0B10 QB7D0Q1-19


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT B 410TStandard three-phase meter with indirect connectionDescriptionFeaturesCIRCUTOR’s CIRWATT B 410T is a standardthree phase indirect connection meter,as a result of all the technological developmentswhich is experiencing the currentmarket. These changes have created newneeds and requirements both in terms ofmore flexible rates, new communicationssystems and a price optimization.ApplicationPower supplyNominal voltage3 x 230 (400) V - 3 x 127 (230) V - 3 x 63,5 (110) VTolerance80% ... 115% U nConsumption< 2 W; < 10 V·AFrequency50 or 60 HzVoltage measurementConnectionAsymmetricalReference voltage 3 x 230 (400) V - 3 x 127 (230) V - 3 x 63,5 (110) V *Frequency50 or 60 HzVoltage consumption of the circuit< 2 W; 10 V·ACurrent measuramentNominal reference current l ref(l max) 1 (2) A or 1 (6) A or 2,5 (10) A or 5 (10) A *Start-up current l st< 0,04 x I trCIRWATT B 410T is suitable to be installedin LV and MV networks being the best solutionor installations with high and mediumconsumptions like shopping malls, industriesand high consumption households.Providing to the market a robust and competitivemeter fully complying with the newEuropean Directive MID (EN 50470) and allthe relevant IEC’s.Minimum current l min< 0,2 x I trCurrent consumption of the circuit< 0,1 V·AAccuracy classAccuracy measured in active <strong>energy</strong> EN 50470 (Class B) - IEC 62053-21 (Class 1)Accuracy measured in reactive <strong>energy</strong> IEC 62053-23 (Class 2)MemoryDataNon-volatile memorySetup and eventsSerial flashBatteryTypeLithiumWorking Life > 20 years @ 30 ºCClockTypeGregorian calendarSourceTemperature compensated oscillatorAccuracy (EN 61038) < 0.5 s / day at 23 ºCEnvironmental influenceOperating temperature range -40 ... +70 ºCStorage temperature range -40 ... +85 ºCTemperature coefficient< 15 ppm/KHumidity95 % máx.InsulationInsulating voltage4 kV a 50 Hz during 1 minImpulse voltage 1.2/50 µs - IEC 62052-11 8 kVProtection degree (IEC 62052-11)IIDisplayTypeLCDNumber of data digits up to 8Size of data digits8 mmDisplay data reading whenthere is no voltage.Yes* Request for other configurationsQ1-20


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT B 410TStandard three-phase meter with indirect connectionFeaturesOptical communications interfaceRate programmingType Serial, two-directional Number of days 12Hardware IEC 62056-21 Types of days 10Protocol REE, based on IEC 870-5-102 Contracts 3Tampering detector Number of Tariffs 9Detection Opening the terminal cover Discrimination 1 hourType Micro-switch Holidays/festivities 30FunctionConstruction featuresDetects intruders whenthere is no voltage.Special days 12Load curveConnection Asymmetrical Number of load curves 2External dimensions DIN 43857 Integration time Programmable: 1 ... 253 minEnclosing features DIN 43859 Recording depth 4000IP Degree (IEC 60529) IP 51 EventsPLC Number of events 200Modulation system DSCK with repeater system Billing closuresHardware CENELEC A or CENELEC B Number of locks 12, per contractProtocolCirPLC and PEP (PLCEncapsulated Protocol)TypeDisabled / Programmabledate and hourOther featuresConnectionsCommunications * Expansion cards *RS-232 / PLCWithout inputs / outputsCIRWATT B 410T indirect connectionRS-485 / PLCRS-232 / RS-2324 relay otuputs (Tariff indicator)2 relay outputs / 4 impulse inputs1 2 3 4 5 6 7 8 9 11RS-485 / RS-4854 pulse inputsRS-232 / RS-485Earth leakage measurementRS-232 / EthernetR-485 / Ethernet* Request for other configurations2 relay outputs / 2 impulse outputs /2 impulse inputsL1L2L3NS1 S2S1 S2P1 P2 S1 S2P1 P2P1 P2DimensionsTerminal cover optionWire cover option6676116711172172205,5255661851,21506717215017267Q1-21


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT B 410TStandard three-phase meter with indirect connectionReferencesClass (Active/Reactive)QuadrantsFrequency (Hz)Measuring range VMeasuring range ACommunicationCOM1CommunicationCOM2TypeCodeB / 2 2 50 or 60 Hz 3x230/400 V …/5A RS232 RS232 CIRWATT B 410-QT5A-70B00 QB660B / 2 2 50 or 60 Hz 3x230/400 V …/5A RS485 RS485 CIRWATT B 410-QT5A-80B00 QB6A0B / 2 2 50 or 60 Hz 3x230/400 V …/5A RS232 RS485 CIRWATT B 410-QT5A-90B00 QB670B / 2 2 50 or 60 Hz 3x230/400 V …/5A RS232 ETHERNET CIRWATT B 410-QT5A-A0B00 QB680B / 2 2 50 or 60 Hz 3x230/400 V …/5A RS485 ETHERNET CIRWATT B 410-QT5A-D0B00 QB690B / 2 2 50 or 60 Hz 3x127/220 V …/5A RS232 RS232 CIRWATT B 410-NT5A-70B00 QBF60B / 2 2 50 or 60 Hz 3x127/220 V …/5A RS485 RS485 CIRWATT B 410-NT5A-80B00 QBFA0B / 2 2 50 or 60 Hz 3x127/220 V …/5A RS232 RS485 CIRWATT B 410-NT5A-90B00 QBF70B / 2 2 50 or 60 Hz 3x127/220 V …/5A RS232 ETHERNET CIRWATT B 410-NT5A-A0B00 QBF80B / 2 2 50 or 60 Hz 3x127/220 V …/5A RS485 ETHERNET CIRWATT B 410-NT5A-D0B00 QBF90Q1-22


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT B 505<strong>Multi</strong>-function three-phase meter with indirect connectionDescriptionFeaturesCIRCUTOR’s CIRWATT B 505 is a standardthree phase indirect connection meter,as a result of all the technological developmentswhich is experiencing the currentmarket. These changes have created newneeds and requirements both in terms ofmore flexible rates, new communicationssystems and a price optimization.ApplicationPower supplyNominal voltage3 x 230 (400) V - 3 x 127 (230) V - 3 x 63,5 (110) VTolerance80% ... 115% U nConsumption< 2 W; < 10 V·AFrequency50 or 60 HzVoltage measurementConnectionAsymmetricalReference voltage 3 x 230 (400) V - 3 x 127 (230) V - 3 x 63,5 (110) V *Frequency50 or 60 HzVoltage consumption of the circuit< 2 W; 10 V·ACurrent measuramentNominal reference current l ref(l max) 1 (2) A or 1 (6) A or 2,5 (10) A or 5 (10) A or 1 (10) A *Start-up current l st< 0,02 x I trCIRWATT B 505 is a 4 quadrants <strong>meters</strong>uitable for heavy or medium industry applications,offering a high degree of securityand precise resolution on the measured<strong>energy</strong> readings. Providing to the market arobust and competitive meter with differentcommunication ports and expansion cards,fully complying with the new European DirectiveMID (EN 50470) and IEC 62053-22for Active Energy (Class 0,5S) and IEC62053-23 for Reactive Energy (Class 1 orClass 2).Minimum current l min< 0,2 x I trCurrent consumption of the circuit< 0,1 V·AAccuracy classAccuracy measured in active <strong>energy</strong>EN 50470 (Class C) - IEC 62053-22 (Class 0,5S)Accuracy measured in reactive <strong>energy</strong> IEC 62053-23 (Class 1 or 2)MemoryDataNon-volatile memorySetup and eventsSerial flashBatteryTypeLithiumWorking Life > 20 years @ 30 ºCClockTypeGregorian calendarSourceTemperature compensated oscillatorAccuracy (EN 61038) < 0.5 s / day at 23 ºCEnvironmental influenceOperating temperature range -40... +70 ºCStorage temperature range -40 ... +85 ºCTemperature coefficient< 15 ppm/KHumidity95 % máx.InsulationInsulating voltage4 kV a 50 Hz during 1 minImpulse voltage 1.2/50 µs - IEC 62052-11 6 kVProtection degree (IEC 62052-11)IIDisplayTypeLCDNumber of data digits up to 8Size of data digits8 mmDisplay data reading whenthere is no voltage.Yes* Request for other configurationsQ1-23


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT B 505<strong>Multi</strong>-function three-phase meter with indirect connectionFeaturesOptical communications interfaceRate programmingType Serial, two-directional Number of days 12Hardware IEC 62056-21 Types of days 10Protocol REE, based on IEC 870-5-102 Contracts 3Tampering detector Number of Tariffs 9Detection Opening the terminal cover Discrimination 1 hourType Micro-switch Holidays/festivities 30FunctionConstruction featuresDetects intruders whenthere is no voltage.Special days 12Load curveConnection Asymmetrical Number of load curves 2External dimensions DIN 43857 Integration time Programmable: 1 ... 253 minEnclosing features DIN 43859 Recording depth 4000IP Degree (IEC 60529) IP 51 EventsNumber of events 200Billing closuresNumber of locksType12, per contractDisabled / Programmabledate and hourOther featuresConnectionsCommunications * Expansion cards *RS-232 / RS-232Without inputs / outputsCIRWATT B 505 three-fase indirect connectionRS-485 / RS-485RS-232 / RS-485RS-232 / Ethernet4 relay otuputs (Tariff indicator)2 relay outputs / 4 impulse inputs4 pulse inputs1 2 3 4 5 6 7 8 9 11R-485 / Ethernet Earth leakage measurement* Request for other configurations2 relay outputs / 2 impulse outputs /2 impulse inputsL1L2L3NS1 S2S1 S2P1 P2 S1 S2P1 P2P1 P2DimensionsWire cover option6671117225561851,215017267Q1-24


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT B 502<strong>Multi</strong>-function three-phase meter with indirect connectionDescriptionFeaturesThere are installations in which due to high<strong>energy</strong> consumption or generation, the accuracyof the meter to be installed is a keyfactor to consider. CIRCUTOR offers thebest option to measure large amounts of<strong>energy</strong>. CIRWATT B 402 is a high accuracymeter, with four quadrants measurementsand different communications and expansioncards.ApplicationIt is specially designed for HV installationswhich requires a strict billing system, differentload profiles and communications. Fullyadapts to the customer’s requirements.Power supplyNominal voltage3 x 230 (400) V - 3 x 127 (230) V - 3 x 63,5 (110) VTolerance80% ... 115% U nConsumption< 2 W; < 10 V·AFrequency50 or 60 HzVoltage measurementConnectionAsymmetricalReference voltage 3 x 230 (400) V - 3 x 127 (230) V - 3 x 63,5 (110) V * **Frequency50 or 60 HzVoltage consumption of the circuit < 2 W; 10 V·ACurrent measuramentNominal reference current l ref(l max) 1 (2) A or 1 (6) A or 2,5 (10) A or 5 (10) A *Start-up current l st< 0,001 x I refMinimum current l min< 0,01 x I refCurrent consumption of the circuit < 0,1 V·AAccuracy classAccuracy measured in active <strong>energy</strong> EN 50470 (Class C) - IEC 62053-22 (Class 0,2S)Accuracy measured in reactive <strong>energy</strong> IEC 62053-23 (Class 0,5 or 1 or 2)MemoryDataNon-volatile memorySetup and eventsSerial flashBatteryTypeLithiumWorking Life > 20 years @ 30 ºCClockTypeGregorian calendarSourceTemperature compensated oscillatorAccuracy (EN 61038) < 0.5 s / day at 23 ºCEnvironmental influenceOperating temperature range -40 ... +70 ºCStorage temperature range -40 ... +85 ºCTemperature coefficientHumidityInsulationInsulating voltageImpulse voltage 1.2/50µs - IEC 62052-11Protection degree (IEC 62052-11)< 15 ppm/K95 % máx.4 kV a 50 Hz during 1 min6 kVDisplayTypeLCDNumber of data digits up to 8Size of data digits8 mmDisplay data reading whenthere is no voltage.YesII* Request for other configurations ** Voltage not avaiable in 1 (10) A modelQ1-25


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT B 502<strong>Multi</strong>-function three-phase meter with indirect connectionFeaturesOptical communications interfaceRate programmingType Serial, two-directional Number of days 12Hardware IEC 62056-21 Types of days 10Protocol REE, based on IEC 870-5-102 Contracts 3Tampering detector Number of Tariffs 9Detection Opening the terminal cover Discrimination 1 hourType Micro-switch Holidays/festivities 30FunctionConstruction featuresDetects intruders whenthere is no voltage.Special days 12Load curveConnection Asymmetrical Number of load curves 2External dimensions DIN 43857 Integration time Programmable: 1 ... 253 minEnclosing features DIN 43859 Recording depth 4000IP Degree (IEC 60529) IP 51 EventsNumber of events 200Billing closuresNumber of locksType12, per contractDisabled / Programmabledate and hourOther featuresConnectionsCommunications * Expansion cards *RS-232 / RS-232Without inputs / outputsCIRWATT B 502 three-fase indirect connectionRS-485 / RS-485RS-232 / RS-485RS-232 / Ethernet4 relay otuputs (Tariff indicator)2 relay outputs / 4 impulse inputs4 pulse inputs1 2 3 4 5 6 7 8 9 11R-485 / Ethernet Earth leakage measurement* Request for other configurations2 relay outputs / 2 impulse outputs /2 impulse inputsL1L2L3NS1 S2S1 S2P1 P2 S1 S2P1 P2P1 P2DimensionsWire cover option6671117225561851,215017267Q1-26


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT B 410 RCThree-phase <strong>energy</strong> meter with built in relayDescriptionFeaturesCIRWATT B 410 RC direct connection withbuilt in relay is a standard three-phase meter,as a result of all the technological developmentswhich is experiencing the currentmarket. These changes have creatednew needs and requirements both in termsof more flexible rates, new communicationssystems and a price optimization.CIRWATT B 410 RC direct connection issuitable for LV applications, adapted tonew market challenges, having differentcommunication systems and expansionmodules. Providing to the market a robustand competitive meter fully complyingwith the new European Directive MID (EN50470- IEC 62053-22). Its built in relay canbe opened and closed remotely and alsothe maximum contracted currents can beprogrammedApplicationCIRWATT B 410 RC is ideal for LV andMV power supplies up to 100A. Differentcommunication channels can be used (dependingon the model): Optical, RS-232,RS-485, Ethernet or PLC (Power Line carrier).The built in relay status could be easilymodified using CIRCUTOR’s software.Power supplyNominal voltageToleranceConsumptionFrequencyDirect3 x 230 (400) V - 3 x 127 (230) V80 % ... 115 % U n20 years @ 30 ºCClockTypeGregorian calendarSourceTemperature compensated oscillatorAccuracy (EN 61038) < 0.5 s/day at 23 ºCEnvironmental influenceOperating temperature range -40 ... +70 ºCStorage temperature range -40 ... +85 ºCTemperature coefficient< 15 ppm/KHumidity95 % máx.InsulationInsulating voltage4 kV a 50 Hz during 1 minImpulse voltage 1.2/50 µs - IEC 62052-11 6 kVProtection degree (IEC 62052-11)IIDisplayTypeLCDNumber of data digits up to 8Size of data digits8 mmDisplay data reading when there is no voltage. YesQ1-27


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT B 410 RCThree-phase <strong>energy</strong> meter with built in relayFeaturesOptical communications interfaceRate programmingType Serial, two-directional Number of days 12Hardware IEC 62056-21 Types of days 10Protocol REE, based on IEC 870-5-102 Contracts 3Tampering detector Number of Tariffs 9Detection Opening the terminal cover Discrimination 1 hourType Micro-switch Holidays/festivities 30FunctionConstruction featuresDetects intruders whenthere is no voltage.Special days 12Load curveConnection Asymmetrical Number of load curves 2External dimensions DIN 43857 Integration time Programmable: 1 ... 253 minEnclosing features DIN 43859 Recording depth 4000IP Degree (IEC 60529) IP 51 EventsPLC Number of events 200Modulation system DSCK with repeater system Billing closuresHardware CENELEC A or CENELEC B Number of locks 12, per contractProtocolCirPLC and PEP (PLCEncapsulated Protocol)TypeDisabled / Programmabledate and hourCircuit breakerConnectionsTypeBistable relayMaximum switching current100 A25 813 4 6 7 9 10 12L1L2L3NDimensionsTerminal cover optionWire cover optionQ1-28


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT CDigital multi-function three-phase meterDescriptionFeaturesDigital multi-function three-phase meter,with 2 or 4 quadrants, with type-1 accuracyin active <strong>energy</strong> and type-2 accuracy in reactive<strong>energy</strong>, direct or indirect metering,with the possibility of programming up to 3contracts.In accordance with the demands and needsof the <strong>electric</strong>ity market, CIRCUTOR hasincluded 2 communications ports (on demand),respecting the IEC and MODBUScommunications protocols. It is committedto future technologies, adapting a range ofType C <strong>meters</strong> to the new communicationssystem, PLC.The main display shows the following visualindicators in standby mode:}}Energy direction}}Reactive capacitive / reactive}}Quadrant being used}}Phases activated and their direction}}Active rate per contract}}The meter also has 3 alarms to indicatethe status of the contact or the installation:critical, non-critical and battery.ApplicationCIRWATT C is ideal for LV and MV powersupplies up to 450 kW.Special 4Q meter for FV plants, with an endlessnumber of communications options.Power supply circuitSelf-poweredNominal voltage<strong>Multi</strong>-range, from 3 x 57.7 / 100 V to 3 x 230 / 400 V acTolerance ± 20 %Consumption< 2 W / 10 V·AFrequency50 ... 60 HzOperating temperature - 20 ... + 60 ºCMetering circuitConnection3 or 4 wires from the same unitReference voltages<strong>Multi</strong>-range, from 3x57.7/100 V to 3x230/400 VacFrequency50 ... 60 HzCurrent circuitNominal base currents.../5 or .../1 A (indirect metering; 10 A (direct metering)Maximum current10 or 2 A (2 x I n) (indirect metering);100 A (10 x I n) (direct metering)AccuracyActive Energy Class 1 (IEC 61036)Reactive Energy Class 1 (IEC 61268)Data memoryFLASH (non-volatile memory)Events: 512 records / Billing closing: 64 /CapacityLoad curve: 213 days / 2nd programmableload curve: 5,120 recordsClock maintenance batteryWorking LifeOperation with no battery or voltageClockTypeLithium10 years (50% load)Maximum 24 hoursQuartz oscillator / grid synchronism(adjustable by the programmer)Quartz oscillator drift < 0.5 s/day at 25 ºCDigital inputs (on demand) 4 inputs (60...300 V ac)Digital outputs (on demand)Verification LED outputRateCommunicationsOptical interfaceCOM 13 mechanical relay outputs (up to 400 V ac) optoMOS20 000 impulses / kW·h or kvar·h, in termsof secondary values (indirect metering);1 000 impulses / kW·h (direct metering)IEC-61107RS-232 / RS-485 / Ethernet / PLC (depending type)ProtocolsIEC-870-5-102, IEC-61107Build featuresEnclosure In compliance with DIN 43859Weight1.9 kgQ1-29


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT CDigital multi-function three-phase meterDimensionsStandardsIEC60687 Static active <strong>energy</strong> <strong>meters</strong> for ac, Class 0.5S, 0.2SIEC61036 Static active <strong>energy</strong> <strong>meters</strong> for ac, Class 1IEC61268 Static reactive <strong>energy</strong> <strong>meters</strong> for ac, Class 1 and 2EN -50081-1EN -50082-2EN 55022EN 61000-4-6EN 61000-4-8Residential emissionsIndustrial immunityDriven emissions: Class B / Radiated emissions: Class BImmunity to RF fields coupled to cables (common mode): 10 VImmunity to magnetic fields and grid frequency: 30 A/mConnections3 / 4 Wire Connection (LV) 3 Wire Connection (MV)3 Wire Connection (MV) Direct meteringQ1-30


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT CDigital multi-function three-phase meterReferencesClass (active/reactive)QuadrantsMeasuring range VMeasuring range AInput / Output relaysInput impulsesCommunication COM1Communication COM2TypeCodeStandard1/2 2 3x57/110 V a 3x230/400 V 10 (100)A - - RS232 - CIRWATT C 410-UD1C-10C0 Q1C5211/2 2 3x57/110 V a 3x230/400 V 10 (100)A - - RS485 - CIRWATT C 410-UD1C-20C0 Q1C5251/2 2 3x57/110 V a 3x230/400 V 10 (100)A - - ETHERNET - CIRWATT C 410-UD1C-30C0 Q1C52D1/2 2 3x57/110 V a 3x230/400 V 10 (100)A - - RS232 RS232 CIRWATT C 410-UD1C-70C0 Q1C52W1/2 2 3x57/110 V a 3x230/400 V 10 (100)A - - RS485 RS485 CIRWATT C 410-UD1C-80C0 Q1C52U1/2 2 3x57/110 V a 3x230/400 V 10 (100)A - - RS232 RS485 CIRWATT C 410-UD1C-90C0 Q1C52T1/2 2 3x57/110 V a 3x230/400 V 10 (100)A - - RS232 ETHERNET CIRWATT C 410-UD1C-A0C0 Q1C52V1/2 2 3x57/110 V a 3x230/400 V …/5A - - RS232 - CIRWATT C 410-UT5C-10C0 Q1C5111/2 2 3x57/110 V a 3x230/400 V …/5A - - RS485 - CIRWATT C 410-UT5C-20C0 Q1C5151/2 2 3x57/110 V a 3x230/400 V …/5A - - ETHERNET - CIRWATT C 410-UT5C-30C0 Q1C51D1/2 2 3x57/110 V a 3x230/400 V …/5A - - RS232 RS232 CIRWATT C 410-UT5C-70C0 Q1C51W1/2 2 3x57/110 V a 3x230/400 V …/5A - - RS485 RS485 CIRWATT C 410-UT5C-80C0 Q1C51U1/2 2 3x57/110 V a 3x230/400 V …/5A - - RS232 RS485 CIRWATT C 410-UT5C-90C0 Q1C51T1/2 2 3x57/110 V a 3x230/400 V …/5A - - RS232 ETHERNET CIRWATT C 410-UT5C-A0C0 Q1C51V4 quadrants - Energy generation1/2 4 3x57/110 V a 3x230/400 V 10 (100)A - - RS232 - CIRWATT C 410-UD1C-10C1 Q1C4211/2 4 3x57/110 V a 3x230/400 V 10 (100)A - - RS485 - CIRWATT C 410-UD1C-20C1 Q1C4251/2 4 3x57/110 V a 3x230/400 V 10 (100)A - - ETHERNET - CIRWATT C 410-UD1C-30C1 Q1C42D1/2 4 3x57/110 V a 3x230/400 V 10 (100)A - - RS232 RS232 CIRWATT C 410-UD1C-70C1 Q1C42W1/2 4 3x57/110 V a 3x230/400 V 10 (100)A - - RS485 RS485 CIRWATT C 410-UD1C-80C1 Q1C42U1/2 4 3x57/110 V a 3x230/400 V 10 (100)A - - RS232 RS485 CIRWATT C 410-UD1C-90C1 Q1C42T1/2 4 3x57/110 V a 3x230/400 V 10 (100)A - - RS232 ETHERNET CIRWATT C 410-UD1C-A0C1 Q1C42V1/2 4 3x57/110 V a 3x230/400 V …/5A - - RS232 - CIRWATT C 410-UT5C-10C1 Q1C4111/2 4 3x57/110 V a 3x230/400 V …/5A - - RS485 - CIRWATT C 410-UT5C-20C1 Q1C4151/2 4 3x57/110 V a 3x230/400 V …/5A - - ETHERNET - CIRWATT C 410-UT5C-30C1 Q1C41D1/2 4 3x57/110 V a 3x230/400 V …/5A - - RS232 RS232 CIRWATT C 410-UT5C-70C1 Q1C41W1/2 4 3x57/110 V a 3x230/400 V …/5A - - RS485 RS485 CIRWATT C 410-UT5C-80C1 Q1C41U1/2 4 3x57/110 V a 3x230/400 V …/5A - - RS232 RS485 CIRWATT C 410-UT5C-90C1 Q1C41T1/2 4 3x57/110 V a 3x230/400 V …/5A - - RS232 ETHERNET CIRWATT C 410-UT5C-A0C1 Q1C41VInputs / outputs1/2 2 3x57/110 V a 3x230/400 V 10 (100)A 4 / 3 Opto RS232 - CIRWATT C 410-UD1C-14C0 Q1C5221/2 2 3x57/110 V a 3x230/400 V 10 (100)A 4 / 3 Rele RS232 - CIRWATT C 410-UD1C-15C0 Q1C5231/2 2 3x57/110 V a 3x230/400 V 10 (100)A 4 / 3 Opto RS485 - CIRWATT C 410-UD1C-24C0 Q1C5261/2 2 3x57/110 V a 3x230/400 V 10 (100)A 4 / 3 Rele RS485 - CIRWATT C 410-UD1C-25C0 Q1C5271/2 2 3x57/110 V a 3x230/400 V …/5A 4 / 3 Opto RS232 - CIRWATT C 410-UT5C-14C0 Q1C5121/2 2 3x57/110 V a 3x230/400 V …/5A 4 / 3 Rele RS232 - CIRWATT C 410-UT5C-15C0 Q1C5131/2 2 3x57/110 V a 3x230/400 V …/5A 4 / 3 Opto RS485 - CIRWATT C 410-UT5C-24C0 Q1C5161/2 2 3x57/110 V a 3x230/400 V …/5A 4 / 3 Rele RS485 - CIRWATT C 410-UT5C-25C0 Q1C517Q1-31


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT D<strong>Multi</strong>-function three-phase high accuracy <strong>energy</strong>meterDescriptionHigh-accuracy meter, metering in 4 quadrants and offering the maximumprogramming and communications flexibility, in order to be suitableany type of requirement. The best option for large-scale consumers.The meter has an LCD display with 3 lines, where all para<strong>meters</strong>are displayed on 2 buttons. The main display shows the following visualindicators in standby mode:}}Energy direction}}Reactive capacitive / reactive}}Quadrant being used}}Phases activated and their direction}}Active rate per contractThe meter also has 3 alarms to indicate the status of the contact or theinstallation: critical, non-critical and battery.ApplicationIt has been specially designed for installations that require: billing bycontract, dual load profile or various remote metering systems operatingin parallel. It adapts to the needs of each client, thanks to the manydifferent communications ports and protocols. (RS-232 - RS-232, RS-232 - RS-485, RS 232 – Ethernet).FeaturesPower supply circuit Self-powered Clock maintenance battery LithiumNominal voltaje Depending on the type Working Life 10 years (50% load)Consumption< 2 W / 10 V·AFrequency 50 or 60 Hz (depending on the type) ClockOperation with nobattery or voltageMaximum 24 hoursOperating temperature - 20 ºC ... + 60 ºC Type System frequency / quartz oscillatorMeasuring circuit Quartz oscillator drift < 0.5 s/day at 25 ºCConnection 3 or 4 wires from the same unit Digital inputs (on demand) 3 inputs (60...300 Vac)Reference voltajes3x63.5/110 V, 3x110/190 V, 3x127/220 V,3x230/400 V (depending on the type)Digital outputs (on demand)Frequency 50 or 60 Hz Verification LED outputCurrent circuitNominal base currents .../5 or .../1 A (indirect reading) CommunicationsRate3 mechanical relay outputs (up to 400Vac) optoMOS (depending on the type)20 000 pulses / kW·h or kvar·h,in terms of secondary valuesMaximum current 10 or 2 A (2 x In) (indirect reading) Optical interface IEC-61107 - Reading / ProgrammingAccuracy COM 1 RS-232 - Reading / ProgrammingActive Energy Class 0.2S or 0.5S COM 2 RS-232 / RS-485 - ReadingReactive Energy Class 0,5 or 1 Protocols IEC-870-5-102, Modbus-RTU, IEC-61107Data memory FLASH (non-volatile memory) Build featuresCapacityEvents: 512 records / Billing closing: 64 /Load curve: 213 days / 2nd programmableload curve: 5.120 recordsEnclosure In compliance with DIN 43859Weight2.2 kgQ1-32


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>StandardsIEC 62052-11 and IEC 62053-22 Static active <strong>energy</strong> <strong>meters</strong> for AC, Class 0.2S and 0.5SIEC 62052-11 and IEC 62053-23 Static reactive <strong>energy</strong> <strong>meters</strong> for AC, Class 2 and 3EN-50081-1EN-50082-2EN 55022EN 61000-4-6EN 61000-4-8Residential emissionsIndustrial immunityDriven emissions: Class B / Radiated emissions: Class BImmunity to RF fields coupled to cables (common mode): 10 VImmunity to magnetic fields and grid frequency: 30 A/mReferencesConsumer typeSTANDARDClassQuadrantsMetering range VMetering range AOptoMOS Input/ Output2 0.5S 4 3x63.5/110 V ... / 5 A - - RS232 RS232 CIRWATT D 405-MT5A-10D2 0.5S 4 3x63.5/110 V ... / 5 A - - RS232 RS485 CIRWATT D 405-MT5A-20D2 0.5S 4 3x63.5/110 V ... / 5 A - 3/4 RS232 RS232 CIRWATT D 405-MT5A-15D2 0.5S 4 3x63.5/110 V ... / 5 A 3/4 - RS232 RS232 CIRWATT D 405-MT5A-14D2 0.5S 4 3x63.5/110 V ... / 5 A - 3/4 RS232 RS485 CIRWATT D 405-MT5A-25D2 0.5S 4 3x63.5/110 V ... / 5 A 3/4 - RS232 RS485 CIRWATT D 405-MT5A-24D1 0.2S 4 3x63.5/110 V ... / 5 A - - RS232 RS232 CIRWATT D 402-MT5A-10D1 0.2S 4 3x63.5/110 V ... / 5 A - - RS232 RS485 CIRWATT D 402-MT5A-20D1 0.2S 4 3x63.5/110 V ... / 5 A - 3/4 RS232 RS232 CIRWATT D 402-MT5A-15D1 0.2S 4 3x63.5/110 V ... / 5 A 3/4 - RS232 RS232 CIRWATT D 402-MT5A-14D1 0.2S 4 3x63.5/110 V ... / 5 A - 3/4 RS232 RS485 CIRWATT D 402-MT5A-25D1 0.2S 4 3x63.5/110 V ... / 5 A 3/4 - RS232 RS485 CIRWATT D 402-MT5A-24DIndicate: Distribution, area, hourly discrimination and current transformer ratio, if applicable.Three-phase <strong>meters</strong> with additional featuresETHERNET COMMUNICATIONS2 0.5S 4 3x63.5/110 V ... / 5 A - - RS232 Ether. CIRWATT D 405-MT5A-30D1 0.2S 4 3x63.5/110 V ... / 5 A RS232 Ether. CIRWATT D 402-MT5A-30DFOR OTHER CONFIGURATIONS (inputs, outputs and other communications), PLEASE ASKRelay Input/ OutputCOM1COM2TYPEConnectionsDimensions3 wire connection (MV)Q1-33


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>CIRWATT DHigh-performance, multi-function static meterReferencesConsumer typeClassQuadrantsMetering range VMetering range AOptoMOS Input / OutputRelay Input / OutputCOM1COM2TYPEcodeSTANDARD2 0.5S 4 3x63.5/110 V ... / 5 A - - RS232 RS232 CIRWATT D 405-MT5A-10D Q1D2512 0.5S 4 3x63.5/110 V ... / 5 A - - RS232 RS485 CIRWATT D 405-MT5A-20D Q1D2552 0.5S 4 3x63.5/110 V ... / 5 A - 3/4 RS232 RS232 CIRWATT D 405-MT5A-15D Q1D2532 0.5S 4 3x63.5/110 V ... / 5 A 3/4 - RS232 RS232 CIRWATT D 405-MT5A-14D Q1D2522 0.5S 4 3x63.5/110 V ... / 5 A - 3/4 RS232 RS485 CIRWATT D 405-MT5A-25D Q1D2572 0.5S 4 3x63.5/110 V ... / 5 A 3/4 - RS232 RS485 CIRWATT D 405-MT5A-24D Q1D2561 0.2S 4 3x63.5/110 V ... / 5 A - - RS232 RS232 CIRWATT D 402-MT5A-10D Q1D0511 0.2S 4 3x63.5/110 V ... / 5 A - - RS232 RS485 CIRWATT D 402-MT5A-20D Q1D0551 0.2S 4 3x63.5/110 V ... / 5 A - 3/4 RS232 RS232 CIRWATT D 402-MT5A-15D Q1D0531 0.2S 4 3x63.5/110 V ... / 5 A 3/4 - RS232 RS232 CIRWATT D 402-MT5A-14D Q1D0521 0.2S 4 3x63.5/110 V ... / 5 A - 3/4 RS232 RS485 CIRWATT D 402-MT5A-25D Q1D0571 0.2S 4 3x63.5/110 V ... / 5 A 3/4 - RS232 RS485 CIRWATT D 402-MT5A-24D Q1D056Indicate: Distribution, area, hourly discrimination and current transformer ratio, if applicable.Three-phase <strong>meters</strong> with additional featuresETHERNET COMMUNICATIONS2 0.5S 4 3x63.5/110 V ... / 5 A - - RS232 Ether. CIRWATT D 405-MT5A-30D Q1D25E1 0.2S 4 3x63.5/110 V ... / 5 A RS232 Ether. CIRWATT D 402-MT5A-30D Q1D05EFOR OTHER CONFIGURATIONS (inputs, outputs and other communications), PLEASE ASKQ1-34


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>PLC-800Concentrator for PLC systemsDescriptionThe PLC800 is the main element of CIRCUTOR’s Smart Meteringsystems. The main function of the PLC800 concentrator is to managethe <strong>electric</strong>al distribution network with the use of CIRWATT <strong>electric</strong>al<strong>energy</strong> <strong>meters</strong>. The information is gathered using the <strong>electric</strong>al cableof the distribution network using the so-called ‘PLC Communications’(Power Line Carrier).The PLC800 concentrator is installed in transformer substations and ituses different communications systems, such as Ethernet, GSM andGPRS, which offer various positions to access the information and interactwith the system.ApplicationThe system offers Plug&Play <strong>functional</strong>ities, so that the CIRWATT <strong>electric</strong>al<strong>energy</strong> <strong>meters</strong> are detected automatically by the PLC800 concentrator,downloading all information to the memory, such as the <strong>energy</strong>load curves, events and billing closures. The PLC800 concentrator alsooffers the possibility of automatically sending this information to an ftpserver.In addition, it offers various specific functions to manage the <strong>electric</strong>al<strong>energy</strong> demand, loss control and fraud detection. All of these actionscan be used for the preventive maintenance and detailed monitoring ofthe behaviour of the <strong>electric</strong>al distribution network.FeaturesPower supplyData memoryWorking voltage 127 V to 230 V Type FLASH (SD card)Power consumption ~7 W and ~12 V·A Capacity 528 MBEnvironmental influencesBatteryOperating temperature range -20 ºC to +60 ºC Type LithiumStorage temperature range -40 ºC to +85 ºC Position InternalHumidity 95% max. Working Life >20 years @ 25 ºCProcessorModemMicroprocessor Samsung S3C2440-300 Type GSM and GPRSDisplay Band QuadribandType / Size TFT LCD / 3,5'' Card SIMBacklight LED Ethernet PortPLC – Power line communications Type IEEE 802.3Type DCSK with repetitive system Connector RJ-45Hardware CENELEC A or CENELEC B Speed 10/100 MbitConnection3 or 4 wires (with dualconnection option)USB PortsProtection class II Version USB 1.1* For other configurations, please ask Type Female, type AQ1-35


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>PLC-800Concentrator for PLC systemsStandardsIEC 61000-4-2IEC 61000-4-3IEC 61000-4-4IEC 61000-4-5IEC 62052-11IEC/CISPR 22UNE-EN 50470Electrostatic discharges : 8 kVElectromagnetic fields (80 Mhz to 2 Ghz): 10V/m 30V/mFast transient burst test : 4 kVSurge test in current and voltage circuits : 6 kVImpulse voltage 1,2/50 µs: 8 kVRadio interference suppression: Class BCurrent and voltage circuits under load: 4 kVReferencesPower supplyvoltage 127... 230 VacPLCCommunicationsbandMetering voltage3x230/400 VNumber of PLCCommunicationsinputsGSM/GPRS ModemUSB PortsEthernet Port• A • 1 • 2 1 PLC800-U-1-2M00-12-0 Q45210• B • 1 • 2 1 PLC800-U-1-4M00-12-0 Q45310• A • 2 • 2 1 PLC800-U-1-2M2M-12-0 Q45211TypeCodeScreens}}Connected meter list}}Modification of contractedcurrents}}Open/close the internal relay}}Electrical para<strong>meters</strong> readingsConnectionsDimensionsTransf 2 Transf 1 SupplyA1A2L1L2L3NL1L2L3NoptionalQ1-36


<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>Relation between products and accessoriesConverters TRMC Modem LOC LM4-PLC SoftwareCommunicationsconvertersCurrent transformers GSM, RTC, protector Optical reader Impulse concentratorManagement andcontrol SoftwareSee M.5 See Q.3 See Q.3 See Q.3 See Q.3 See Q.3CIRWATT A- - - • • •CIRWATT B- - - • • •CIRWATT C• • • • • •CIRWATT D• • • • • •PLC-800- - - - • •Q1-37


Q1-38<strong>Multi</strong>-<strong>functional</strong> <strong>electric</strong> <strong>energy</strong> <strong>meters</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!