Burlington TS Overload Protection/Load Rejection scheme(CAA ID Number: 2006-EX298)<strong>Hydro</strong> <strong>One</strong> indicated that this proposed scheme is intended as a back-up or insurance policy in the case of an abnormal oremergency situation where pre-contingency control actions (e.g. load transfer and/or opening A1A2 or H1H2) areunavailable to minimize post-contingency loads below the 15-MIN LTR of the autotransformers.4.0 <strong>ASSESSMENT</strong>As per NPCC criteria the proposed scheme is deemed a type 3 SPS. The failure of the proposed scheme will not affect theinterconnected power system since these autotransformers serve the Burlington local area. However, IESO's "OntarioResource and Transmission Assessment Criteria" document # IMO_REQ_0041 stipulates in section 3.4.1 that "A SPSproposed in a connection assessment must have full redundancy and separation of the communication channels, and mustsatisfy the requirements of the NPCC Type I SPS criteria to be considered by the IESO". The proposed scheme does notmeet these requirements.As shown in Table 3, the 15-MIN and 10-DAY LTRs of the four autotransformers at Burlington TS are limited to valuessignificantly lower than the 2 pu trigger values of the proposed scheme. It can also be observed that the 15-MIN LTRs arenot much higher than the continuous ratings.Burlington TSExisting ratings of autotransformers 2(limited by 115 kV elements)See note 2Continuous(MVA)10-Day LTR (MVA)15-Min LTR (MVA)T4 250 261 272T6 215 256 289T9 250 256 265T12 250 257 267Table 3: Existing Ratings of Autotransformers at Burlington TSThe proposed scheme could result in an autotransformer loaded above its 15-MIN LTR. For certain load conditions, theoperation of the proposed scheme may reduce the loading below the 2 pu point but not below the 15-MIN LTRs of theautotransformer.5.0 CONCLUSIONSThe proposed scheme does not meet the criteria for a type 1 SPS as stated in section 3.4.1 of the "Ontario Resource andTransmission Assessment Criteria".The operation of the proposed scheme could result in a load level on an auto-transformer that is above its 15-MIN LTR butbelow the 2 pu level. Therefore, post-contingency control actions such as load shedding or transfers may still be required.6.0 REQUIREMENTS<strong>Hydro</strong> <strong>One</strong> <strong>Networks</strong> Inc. must notify the IESO as soon as it becomes aware of any changes to the assumptions made in theconnection assessment. The IESO will determine whether these changes require a re-assessment.2 The 10-DAY and 15-MIN LTRs for T6 after it is upgraded will be listed in CAA report # 2006-EX299. These ratings are subject tochange.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!