SRF-ZJX Floor Console Hyper InverterSRR-ZJX Compact Ducted Hyper Inverter• Floor standing or low wall mounted• Pipe length up to 30m on SRF50• Downward air discharge for heating mode• Refrigerant fully charged for 15m pipe lengthSelling Category CSee P7 for additionalControls and Adaptors• Compact Ducted Unit with three fan speeds• Infra-red Control with 24hr timer• Return Air filter included• Optional condensate pump and spigot kit• Refrigerant fully charged for 15m pipe lengthSelling Category CINDOOR UNIT c/w IR Controller SRF25ZJX-S SRF35ZJX-S SRF50ZJX-SHRP Code 625503 625508 625513LIST <strong>Price</strong> €855 €960 €966OUTDOOR UNIT SRC25ZJX-S SRC35ZJX-S SRC50ZJX-SHRP Code 625448 625458 625478LIST <strong>Price</strong> €751 €837 €1,391SYSTEM Code 624250 624252 624254SYSTEM LIST <strong>Price</strong> €1,606 €1,797 €2,357Full range of Installation Accessoriesavailable from HRP (see p42 - 45):Copper TubeINDOOR UNIT c/w IR Controller SRR25ZJ-S SRR35ZJ-SHRP Code 625330 625336LIST <strong>Price</strong> €927 €1,032OUTDOOR UNIT SRC25ZJX-S SRC35ZJX-SHRP Code 625448 625458LIST <strong>Price</strong> €751 €837SYSTEM Code 624245 624248SYSTEM LIST <strong>Price</strong> €1,678 €1,869Accessories for SRK-ZJ/ZK/ZJX, SRF & SRRHRP Code <strong>List</strong> <strong>Price</strong>SC-BIKN-E Adaptor for Wired Remote 623463 €204RC-E4 Remote Control - Wired 623463 €86PJA504A178XR 6-Wire Adaptor 633086 €21BBF12 Back Return Filter - SRR 623323 €121Cooling (Nominal) kW 2.5 3.5 5Cooling Range kW 0.9 to 3.2 0.9 to 4.1 0.7 to 5.5UK Cooling Nom kW 2.4 3.3 4.8UK Sensible Cooling Nom kW 2.1 2.6 3.5E.E.R (Energy Label) 4.80 (A) 3.93 (A) 3.60 (A)Heating (Nominal) kW 3.4 4.5 6Heating Range kW 0.9 to 4.7 0.9 to 5.1 0.7 to 7.0C.O.P (Energy Label) 4.70 (A) 4.00 (A) 3.90 (A)Operating Range (Outdoor Air) Cooling oC DB -15 to 46Operating Range (Outdoor Air) Heating oC WB -15 to 21Wall BracketsCooling (Nominal) kW 2.5 3.5Cooling Range kW 0.9 to 3.2 0.9 to 5.1UK Cooling Nom kW 2.4 3.3UK Sensible Cooling Nom kW 2 2.5E.E.R. (Energy Label) 4.31 (A) 3.24 (B)Heating (Nominal) kW 3.4 4.2Heating Range kW 0.9 to 4.7 0.9 to 5.1C.O.P (Energy Label) 4.53 (A) 3.82 (A)Operating Range (Outdoor Air) Cooling ºC DB - 5 to 46Operating Range (Outdoor Air) Heating ºC WB -5 to 21INDOOR UNITExterior Dimensions (H x W x D) mm 600 x 860 x 238 600 x 860 x 238 600 x 860 x 238Net Weight kg 18 19 19Air Volume (L/M/H) Cooling m3/s 0.10 – 0.13 – 0.15 0.11 – 0.13 – 0.15 0.11 – 0.16 – 0.19Air Volume (L/M/H) Heating m3/s 0.11 – 0.1 – 0.18 0.12 – 0.14 – 0.18 0.13 – 0.17 – 0.20Sound Pressure Level (L/M/H) Cooling dB(A) 26 / 32 / 40 28 / 34 / 41 30 / 39 / 47Sound Pressure Level (L/M/H) Heating dB(A) 28 / 35 / 40 31 / 36 / 41 32 / 39 / 47OUTDOOR UNITExterior Dimensions (H x W x D) mm 595 x 780 (+62) x 290 595 x 780 (+62) x 290 640 x 800(+71) x 290Net Weight kg 38 38 43Sound Pressure Level dB(A) 47 50 48ELECTRICAL DATAPower Source Rating MCB A 16 16 20Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50HzInterconnecting Wires 3 + E 3 + E 3 + ERunning Current - Cooling Nom (Max) A 2.5 (8) 3.9 (8) 6.1 (14)Running Current - Heating Nom (Max) A 3.4 (8) 4.9 (8) 6.8 (14)Power Input - Cooling Nom kW 0.52 0.89 1.39Power Input - Heating Nom kW 0.72 1.12 1.54Start Current A 3.4 4.9 6.8INSTALLATION/REFRIGERANTRef. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 1/4” (6.35)Gas 3/8” (9.52) 3/8” (9.52) 1/2” (12.7)Ref. Max Piping Length m 15 15 30Vertical Height Difference (Max)- Outdoor Unit Above Indoor Unit m 10 10 20- Outdoor Unit Below Indoor Unit m 10 10 20Refrigerant Amount Precharged kg 1.2 1.2 1.4- For Pipe Length Up To m 15 15 15Additional Refrigerant g/m n/a n/a 20Condensate PumpsAvailable from HRP <strong>Ltd</strong> UK,Tel: 0044 (0)1925 837 688INDOOR UNITExterior Dimensions (H x W x D) mm 230 x 740 x 455 230 x 740 x 455Net Weight kg 22 22Air Volume (L - M - H) Cooling m3/s 0.08 - 0.12 - 0.14 0.09 - 0.13 - 0.15Air Volume (L - M - H) Heating m3/s 0.11 - 0.15 - 0.17 0.12 - 0.16 - 0.18Sound Pressure Level (L/M/H) Cooling dB(A) 29 / 35 / 40 30 / 37 / 42Sound Pressure Level (L/M/H) Heating dB(A) 31 / 38 / 41 32 / 40 / 43OUTDOOR UNITExterior Dimensions (H x W x D) mm 595 x 780(+62) x 290 595 x 780(+62) x 290Net Weight kg 38 38Sound Pressure Level dB(A) 47 50ELECTRICAL DATAPower Source Rating MCB A 16 16Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50HzInterconnecting Wires 3 + E 3 + ERunning Current - Cooling Nom (Max) A 2.8 (8) 4.7 (8)Running Current - Heating Nom (Max) A 3.6 (8) 4.8 (8)Power Input - Cooling Nom kW 0.58 1.08Power Input - Heating Nom kW 0.75 1.1Start Current A 4 5INSTALLATION/REFRIGERANTRef. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35)Gas 3/8” (9.52) 3/8” (9.52)Ref. Max Piping Length m 15 15Vertical Height Difference (Max)- Outdoor Unit Above Indoor Unit m 10 10- Outdoor Unit Below Indoor Unit m 10 10Refrigerant Amount Precharged kg 1.2 1.2- For Pipe Length Up To m 15 15Additional Refrigerant g/m n/a n/a6 www.3dair .co.uk7


SCM-ZJ Inverter Multi Systems• Up to six indoor units on larger systems• Individually controlled indoor units• All indoor units operate in same Mode• Choice of Wall, Cassette, Ducted,Floor unitsOutdoor unitsSelling Category CSCM45, SCM60 SCM80 SCM100, SCM125OUTDOOR UNIT SCM45ZJ-S SCM60ZJ-S SCM80ZJ-S SCM100ZJ-S SCM125ZJ-SHRP Code 625217 625233 625241 625249 625257LIST <strong>Price</strong> €1,511 €2,389 €2,966 TBC TBCCooling (Nominal) kW 4.5 6 8 TBC TBCCooling Range kW 1.8 to 6.4 1.8 to 7.5 1.8 to 9.2 TBC TBCE.E.R (Energy Label) 4.33 (A) 4.20 (A) 3.70 (A) TBC TBCHeating (Nominal) kW 5.6 6.8 9.3 TBC TBCHeating Range kW 1.4 to 7.4 1.5 to 7.8 1.5 to 9.8 TBC TBCC.O.P (Energy Label) 4.67 (A) 4.50 (A) 4.12 (A) TBC TBCExterior Dimensions (H x W x D) mm 640 x 850(+65) x 290 640 x 850(+65) x 290 750 x 880(+73) x 340 TBC TBCNet Weight kg 47 49 62 TBC TBCSound Pressure Level dB(A) 49 52 54 TBC TBCNumber of Indoor Units Min-Max 1 - 2 2 - 3 2 - 4 TBC TBCELECTRICAL DATAPower Source Rating MCB A 16 20 20Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz TBC TBCInterconnecting Wires 3 + E (x2) 3 + E (x3) 3 + E (x4) TBC TBCRunning Current - Cooling Nom (Max) A 4.6 (14) 6.5 (17) 9.4 (20) TBC TBCRunning Current - Heating Nom (Max) A 5.3 (14) 6.8 (17) 10 (20) TBC TBCPower Input - Cooling Nom kW 1.04 1.43 2.16 TBC TBCPower Input - Heating Nom kW 1.2 1.51 2.26 TBC TBCStart Current A 6 7 10 TBC TBCINSTALLATION/REFRIGERANTRef. Piping Size o.d ins (mm) Liquid 1/4” (6.35) x 2 1/4” (6.35) x 3 1/4” (6.35) x 4 TBC TBCGas 3/8” (9.52) x 2 3/8” (9.52) x 3 3/8” (9.52) x 4 TBC TBCRef. Max Piping Length (Unit/Total) m 25/30 25/40 25/70 TBC TBCVertical Height Difference (Max)- Outdoor Unit Above Indoor Unit m 15 15 20 TBC TBC- Outdoor Unit Below Indoor Unit m 15 15 20 TBC TBCRefrigerant Amount Precharged kg 1.6 2.2 3.15 TBC TBC- For Pipe Length Up To m 20 30 40 TBC TBCAdditional Refrigerant g/m 20 20 20TBC TBC TBCMote: Mains Power to Outdoor Unit. Interconnecting 3core+ E to each Indoor Unit• Simple interconnecting pipelayout with each Indoor Unitindividually connected toOutdoor UnitIndoor unitsSelling Category CSRKZJFDTC CASSETTE c/wWIRED Controller RC-E4 FDTC25VD FDTC35VD FDTC50VD FDTC60VDFascia Panel TC-PSA-25W-E TC-PSA-25W-E TC-PSA-25W-E TC-PSA-25W-ECode (Cassette + Fascia + RC-E4 Controller) 622973 622978 622983 622988LIST <strong>Price</strong> (Cass. + Fascia + Controller) €997 €1,002 €1,033 €1,103Cooling (Nominal) kW 2.5 3.5 5 6Heating (Nominal) kW 3.4 4.5 5.8 6.8Air Volume (Heating - High Speed) m3/s 0.16 0.17 0.19 0.23Sound Pressure Level(Heating - High Speed) dB(A) 38 42 42 46Exterior Dimensions (H x W x D) Unit mm 248 x 570 x 570 248 x 570 x 570 248 x 570 x 570 248 x 570 x 570Panel mm 35 x 700 x 700 35 x 700 x 700 35 x 700 x 700 35 x 700 x 700Net Weight Unit (Fascia Panel) kg 15 (3.5) 15 (3.5) 15 (3.5) 15 (3.5)Ref. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) 1/4” (6.35)Gas 3/8” (9.52) 3/8” (9.52) 1/2” (12.7) 1/2” (12.7)SRF FLOOR STANDING(c/w IR Controller) SRF25ZJX-S SRF35ZJX-S SRF50ZJX-SCode 625503 625508 625513LIST <strong>Price</strong> €855 €960 €966Cooling (Nominal) kW 2.5 3.5 5Heating (Nominal) kW 3.4 4.5 5.8Air Volume (Heating - High Speed) m3/s 0.18 0.18 0.2Sound Pressure Level(Heating - High Speed) dB(A) 40 41 47Exterior Dimensions (H x W x D) mm 600 x 860 x 238 600 x 860 x 238 600 x 860 x 238Net Weight kg 18 19 19Ref. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 1/4” (6.35)Gas 3/8” (9.52) 3/8” (9.52) 1/2” (12.7)FDTCSRFSRRFDTCIndoor unitsSRRSRR DUCTED c/w IR Controller SRR25ZJ-S SRR35ZJ-S SRR50ZJ-S SRR60ZJ-SHRP Code 625330 625336 625346 625354LIST <strong>Price</strong> €927 €1,032 €1,224 €1,326Cooling (Nominal) kW 2.5 3.5 5 6Heating (Nominal) kW 3.4 4.5 5.8 6.8Air Volume (Heating - High Speed) m3/s 0.17 0.18 0.22 0.25Sound Pressure Level (Heating - High Speed) dB(A) 41 43 48 51Exterior Dimensions (H x W x D) mm 230 x 740 x 455 230 x 740 x 455 230 x 740 x 455 230 x 740 x 455Net Weight kg 22 22 23 23Ref. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) 1/4” (6.35)Gas 3/8” (9.52) 3/8” (9.52) 1/2” (12.7) 1/2” (12.7)SRK WALL MOUNTEDc/w IR Controller SRK25ZJ-S SRK35ZJ-S SRK50ZJ-SCode 625083 625098 625108LIST <strong>Price</strong> €397 €437 €604Cooling (Nominal) kW 2.5 3.5 5Heating (Nominal) kW 3.4 4.5 5.8Air Volume (Heating - High Speed) m3/s 0.18 0.21 0.23Sound Pressure Level(Heating - High Speed) dB(A) 39 43 45Exterior Dimensions (H x W x D) mm 294 x 798 x 229 268 x 790 x 199 268 x 790 x 199Net Weight kg 9.5 9.5 9.5Ref. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 1/4” (6.35)Gas 3/8” (9.52) 3/8” (9.52) 1/2” (12.7)SRKZJAVAILABLE SUMMER <strong>2011</strong>FDEN50VD Ceiling Suspended& FDUM50VD Ducted Indoor Unitsfor connection to SCM Multi Systems8www.hrponline.co.uk9


Inverter multi system combinations SCM• Combinations can be selected from the Indoor Unit models listed on Pages 8 - 9.Outdoor Indoor Unit Type Indoor Cooling HeatingUnit SRK FDTC SRR SRF Model kW kWSCM45ZJ-S Indoor A ✓ ✓ ✓ ✓ 25 2.50 3.40Indoor B - - -SCM45ZJ-S Indoor A ✓ ✓ ✓ ✓ 35 3.50 4.50Indoor B - - -SCM45ZJ-S Indoor A ✓ ✓ ✓ ✓ 25 2.50 3.25Indoor B ✓ ✓ ✓ ✓ 25 2.50 3.25SCM45ZJ-S Indoor A ✓ ✓ ✓ ✓ 35 3.38 3.79Indoor B ✓ ✓ ✓ ✓ 25 2.42 2.71SCM45ZJ-S Indoor A ✓ ✓ ✓ ✓ 35 2.90 3.25Indoor B ✓ ✓ ✓ ✓ 35 2.90 3.25Outdoor Indoor Unit Type Indoor Cooling HeatingUnit SRK FDTC SRR SRF Model kW kWSCM60ZJ-S Indoor A ✓ ✓ ✓ ✓ 25 2.45 3.15Indoor B ✓ ✓ ✓ ✓ 25 2.45 3.15Indoor C - - -SCM60ZJ-S Indoor A ✓ ✓ ✓ ✓ 35 3.38 3.91Indoor B ✓ ✓ ✓ ✓ 25 2.42 2.79Indoor C - - -SCM60ZJ-S Indoor A ✓ ✓ ✓ ✓ 50 4.47 4.73Indoor B ✓ ✓ ✓ ✓ 25 2.23 2.37Indoor C - - -SCM60ZJ-S Indoor A ✓ ✓ 60 4.73 5.01Indoor B ✓ ✓ ✓ ✓ 25 1.97 2.09Indoor C - - -SCM60ZJ-S Indoor A ✓ ✓ ✓ ✓ 35 3.30 3.50Indoor B ✓ ✓ ✓ ✓ 35 3.30 3.50Indoor C - - -SCM60ZJ-S Indoor A ✓ ✓ ✓ ✓ 50 3.94 4.18Indoor B ✓ ✓ ✓ ✓ 35 2.76 2.92Indoor C - - -SCM60ZJ-S Indoor A ✓ ✓ 60 4.23 4.48Indoor B ✓ ✓ ✓ ✓ 35 2.47 2.62Indoor C - - -SCM60ZJ-S Indoor A ✓ ✓ ✓ ✓ 50 3.35 3.55Indoor B ✓ ✓ ✓ ✓ 50 3.35 3.55Indoor C - - -SCM60ZJ-S Indoor A ✓ ✓ ✓ ✓ 25 2.00 2.27Indoor B ✓ ✓ ✓ ✓ 25 2.00 2.27Indoor C ✓ ✓ ✓ ✓ 25 2.00 2.27SCM60ZJ-S Indoor A ✓ ✓ ✓ ✓ 35 2.51 2.88Indoor B ✓ ✓ ✓ ✓ 25 1.79 2.06Indoor C ✓ ✓ ✓ ✓ 25 1.79 2.06SCM60ZJ-S Indoor A ✓ ✓ ✓ ✓ 50 3.20 3.60Indoor B ✓ ✓ ✓ ✓ 25 1.60 1.80Indoor C ✓ ✓ ✓ ✓ 25 1.60 1.80SCM60ZJ-S Indoor A ✓ ✓ ✓ ✓ 35 2.36 2.62Indoor B ✓ ✓ ✓ ✓ 35 2.36 2.62Indoor C ✓ ✓ ✓ ✓ 25 1.68 1.87SCM60ZJ-S Indoor A ✓ ✓ ✓ ✓ 35 2.20 2.40Indoor B ✓ ✓ ✓ ✓ 35 2.20 2.40Indoor C ✓ ✓ ✓ ✓ 35 2.20 2.4010Outdoor Indoor Unit Type Indoor Cooling HeatingUnit SRK FDTC SRR SRF Model kW kWSCM80ZJ-S Indoor A ✓ ✓ ✓ ✓ 25 2.37 2.83Indoor B ✓ ✓ ✓ ✓ 25 2.37 2.83Indoor C ✓ ✓ ✓ ✓ 25 2.37 2.83Indoor D - - -SCM80ZJ-S Indoor A ✓ ✓ ✓ ✓ 35 3.21 3.71Indoor B ✓ ✓ ✓ ✓ 25 2.29 2.65Indoor C ✓ ✓ ✓ ✓ 25 2.29 2.65Indoor D - - -SCM80ZJ-S Indoor A ✓ ✓ ✓ ✓ 50 3.90 4.50Indoor B ✓ ✓ ✓ ✓ 25 1.95 2.25Indoor C ✓ ✓ ✓ ✓ 25 1.95 2.25Indoor D - - -SCM80ZJ-S Indoor A ✓ ✓ 60 4.25 4.91Indoor B ✓ ✓ ✓ ✓ 25 1.77 2.05Indoor C ✓ ✓ ✓ ✓ 25 1.77 2.05Indoor D - - -SCM80ZJ-S Indoor A ✓ ✓ ✓ ✓ 35 2.87 3.32Indoor B ✓ ✓ ✓ ✓ 35 2.87 3.32Indoor C ✓ ✓ ✓ ✓ 25 2.05 2.37Indoor D - - -SCM80ZJ-S Indoor A ✓ ✓ ✓ ✓ 50 3.55 4.09Indoor B ✓ ✓ ✓ ✓ 35 2.48 2.86Indoor C ✓ ✓ ✓ ✓ 25 1.77 2.05Indoor D - - -SCM80ZJ-S Indoor A ✓ ✓ 60 3.90 4.50Indoor B ✓ ✓ ✓ ✓ 35 2.28 2.63Indoor C ✓ ✓ ✓ ✓ 25 1.63 1.88Indoor D - - -SCM80ZJ-S Indoor A ✓ ✓ ✓ ✓ 50 3.12 3.60Indoor B ✓ ✓ ✓ ✓ 50 3.12 3.60Indoor C ✓ ✓ ✓ ✓ 25 1.56 1.80Indoor D - - -SCM80ZJ-S Indoor A ✓ ✓ ✓ ✓ 35 2.60 3.00Indoor B ✓ ✓ ✓ ✓ 35 2.60 3.00Indoor C ✓ ✓ ✓ ✓ 35 2.60 3.00Indoor D - - -SCM80ZJ-S Indoor A ✓ ✓ ✓ ✓ 50 3.25 3.75Indoor B ✓ ✓ ✓ ✓ 35 2.28 2.63Indoor C ✓ ✓ ✓ ✓ 35 2.28 2.63Indoor D - - -SCM80ZJ-S Indoor A ✓ ✓ 60 3.60 4.15Indoor B ✓ ✓ ✓ ✓ 35 2.10 2.42Indoor C ✓ ✓ ✓ ✓ 35 2.10 2.42Indoor D - - -SCM80ZJ-S Indoor A ✓ ✓ ✓ ✓ 25 1.98 2.30Indoor B ✓ ✓ ✓ ✓ 25 1.98 2.30Indoor C ✓ ✓ ✓ ✓ 25 1.98 2.30Indoor D ✓ ✓ ✓ ✓ 25 1.98 2.30SCM80ZJ-S Indoor A ✓ ✓ ✓ ✓ 35 2.51 2.93Indoor B ✓ ✓ ✓ ✓ 25 1.80 2.09Indoor C ✓ ✓ ✓ ✓ 25 1.80 2.09Indoor D ✓ ✓ ✓ ✓ 25 1.80 2.09SCM80ZJ-S Indoor A ✓ ✓ ✓ ✓ 50 3.20 3.72Indoor B ✓ ✓ ✓ ✓ 25 1.60 1.86Indoor C ✓ ✓ ✓ ✓ 25 1.60 1.86Indoor D ✓ ✓ ✓ ✓ 25 1.60 1.86SCM80ZJ-S Indoor A ✓ ✓ ✓ ✓ 35 2.33 2.71Indoor B ✓ ✓ ✓ ✓ 35 2.33 2.71Indoor C ✓ ✓ ✓ ✓ 25 1.67 1.94Indoor D ✓ ✓ ✓ ✓ 25 1.67 1.94For SCM 100 & 125 Combinations -please contact 3D/HRPwww.3dair .co.uk11


Technical NotesFDTC Compact CassetteMHI Cassette SystemsFDT Standard & FDTC Compact (600 x 600)New product features now include Independent LouverControl, allowing air flow patterns to be customised to thesize and shape of each conditioned space. This independentcontrol can also help to deal with unwanted drafts.The position of each louver can be set on the Wired Controller RC-E4• 4-way discharge with individual louver control• Fits 600mm x 600mm ceiling grid• Branch duct facility• Low ambient operation to -15ºC• Refrigerant charged up to 30m pipe lengthSelling Category CINDOOR UNIT FDTC25VD FDTC35VD FDTC40VD FDTC50VD FDTC60VDHRP Code 628650 628655 628364 628396 628660LIST <strong>Price</strong> €716 €721 €731 €752 €823FASCIA PANEL TC-PSA-25W-E TC-PSA-25W-E TC-PSA-25W-E TC-PSA-25W-E TC-PSA-25W-EHRP Code 627043 627043 627043 627043 627043LIST <strong>Price</strong> €196 €196 €196 €196 €196WIRED CONTROLLER RC-E4 RC-E4 RC-E4 RC-E4 RC-E4HRP Code 623194 623194 623194 623194 623194LIST <strong>Price</strong> €86 €86 €86 €86 €86OUTDOOR UNIT SRC25ZJX-S SRC35ZJX-S SRC40ZJX-S SRC50ZJX-S SRC60ZJX-SHRP Code 625448 625458 625468 625478 625488LIST <strong>Price</strong> €751 €837 €1,112 €1,391 €1,548(option)RC-E4 Multi Function Wired ControllerThe RC-E4 (623194) is supplied as standard on all FD splitsystems. As well as the normal function of Set Temperatureadjustment and Fan Speed selection, the wired controller hasthe following technical advantages:• Integral temperature sensor, which can be used as analternative to the the indoor unit return air sensor• Digital display of operating data, including compressorfrequency and speed, valve openings, system pressures andtemperatures at various points• Full diagnosis of system failure - see P38-39 for Error Codes• Facility to eliminate selected display data• Group Control for up to 16 systems• The RC-E4 can also be used on all SRK Inverter systems,using Adaptor Kit SC-BIKN-ERCH-E3 Simplified Controller is an alternative wired controllerdesigned for hotel rooms, offices and other sreas, where fullfunctions are not required.6-Way Adaptor CnTThis low cost Adaptor(633086) allows on/off (12v) switchingvia a volt free contact. It plugs into the indoor unit pcb on FDseries indoor units, including all of the KX range. It also plugsinto the SC-BIKN-E adaptor for SRK-JZ/ZK/ZJX, SRF & SRR.The adaptor allows low voltage output signals to indicate:Cooling, Heating, and Common Fault signal.RC-E4 Controller with IntegralTemperature SensorRCH-E3 Simplified Wired Controller(hotel) - also has Integral SensorFDTC Space CollarsSelling Category – BSpace Collar - for restricted ceiling height (FDTC Cassettes)HRP Code<strong>List</strong> <strong>Price</strong>50mm height 623842 €308100mm height 623858 €261150mm height 623864 €261HRP SYSTEM Code 622976 622981 622872 622878 622986SYSTEM LIST <strong>Price</strong> €1,749 €1,840 €2,125 €2,425 €2,653Cooling (Nominal) kW 2.6 3.6 4 5 5Cooling Range kW 0.9 to 3.2 0.9 to 4.1 1.8 to 4.7 2.2 to 5.6 2.2 to 5.6UK Cooling Nom kW 2.4 3.4 3.8 4.8 5.4UK Sensible Cooling Nom kW 2.2 2.6 3.2 3.6 3.8E.E.R (Energy Label) 4.25 (A) 3.36 (A) 3.85 (A) 3.21 (C) 3.21 (C)Heating (Nominal) kW 3.5 4.3 4.5 5.4 5.4Heating Range kW 0.9 to 4.7 0.9 to 5.1 2.0 to 5.4 2.5 to 6.3 2.5 to 6.3C.O.P (Energy Label) 4.11 (A) 3.66 (B) 4.09 (A) 3.72 (A) 3.72 (A)INDOOR UNITExterior Dimensions (H x W x D) Unit mm 248 x 570 x 570 248 x 570 x 570 248 x 570 x 570 248 x 570 x 570 248 x 570 x 570Panel mm 35 x 700 x 700 35 x 700 x 700 35 x 700 x 700 35 x 700 x 700 35 x 700 x 700Net Weight Unit (Fascia Panel) kg 15 (3.5) 15 (3.5) 15 (3.5) 15 (3.5) 15 (3.5)Air Volume* (L - M - H - EH) Cooling m3/s 0.11 - 0.13 - 0.15 - 0.17 0.12 - 0.15 - 0.16 - 0.18 0.12 - 0.15 - 0.19 - 0.23 0.12 - 0.15 - 0.19 - 0.23 0.12 - 0.17- 0.23 - 0.23Air Volume* (L - M - H - EH) Heating m3/s 0.12 - 0.14 - 0.16 - 0.18 0.13 - 0.15 - 0.17 - 0.19 0.13 - 0.15 - 0.19 - 0.23 0.13 - 0.15 - 0.19 - 0.23 0.13 - 0.17 - 0.23 - 0.23Sound Pressure Level (L/M/H - EH) Cooling dB(A) 29 / 32 / 36 / 38 30 / 36 / 40 / 41 30 / 36 / 42 / 47 30 / 36 / 42 / 47 30 / 39 / 46 / 47Sound Pressure Level (L/M/H - EH) Heating dB(A) 29.5 / 33 / 38 / 39 32 / 35 / 42 / 43 32 / 36 / 42 / 47 32 / 36 / 42 / 47 32 / 39 / 46 / 47OUTDOOR UNITExterior Dimensions (H x W x D) mm 595 x 780(+62) x 290 595 x 780(+62) x 290 640 x 800(+71) x 290 640 x 800(+71) x 290 640 x 800(+71) x 290Net Weight kg 38 38 45 45 45Sound Pressure Level dB(A) 47 50 50 54 54ELECTRICAL DATAPower Source Rating MCB A 16 16 16 20 20Mains Power To Outdoor 230v/1ph/50Hz 230v/1ph/50Hz 230v/1ph/50Hz 230v/1ph/50Hz 230v/1ph/50HzInterconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + ERunning Current - Cooling Nom (Max) A 2.9 (9) 4.7 (9) 4.6 (12) 6.9 (14) 8.3 (14)Running Current - Heating Nom (Max) A 4 (9) 5.1 (9) 4.9 (12) 6.4 (14) 8.7 (14)Power Input - Cooling Nom kW 0.6 1.07 1.04 1.56 1.99Power Input - Heating Nom kW 0.84 1.16 1.1 1.45 2.08Start Current A 4.1 5.3 5.0 5.0 5.0INSTALLATION/REFRIGERANTRef. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) 1/4” (6.35)Gas 3/8” (9.52) 3/8” (9.52) 1/2” (12.7) 1/2” (12.7) 1/2” (12.7)Ref. Max Piping Length m 15 15 30 30 30Vertical Height Difference (Max)- Outdoor Unit Above Indoor Unit m 10 10 20 20 20- Outdoor Unit Below Indoor Unit m 10 10 15 15 15Refrigerant Amount Precharged kg 1.2 1.2 1.4 1.4 1.4- For Pipe Length Up To m 15 15 15 15 15Additional Refrigerant g/m n/a n/a 20 20 2012* If wireless remote controller is used, only 3 fan speeds are available: LOW/MED/HIGH.For FDTC Space Collars - please refer to Page 12www.hrponline.co.uk13


FDT Cassette Inverter SystemsFDT Cassette Hyper Inverter Systems• 4-way discharge with individual louver control• Wired Contrller standard, Infra-red option• Branch duct facility and fresh air inlet• Low ambient operation to -15ºC• Refrigerant charged up to 30m pipe lengthSelling Category -BFDT 1-Phase SystemsStandardOptionFDT 3-Phase SystemsINDOOR UNIT FDT40VD FDT50VD FDT60VD FDT71VD FDT100VD FDT125VD FDT140VD FDT100VD FDT125VD FDT140VDHRP Code 628380 628412 628428 628444 628460 628476 628492 628460 628476 628492LIST <strong>Price</strong> €723 €729 €835 €933 €1,113 €1,341 €1,564 €1,113 €1,341 €1,564FASCIA PANEL T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-EHRP Code 623209 623209 623209 623209 623209 623209 623209 623209 623209 623209LIST <strong>Price</strong> €204 €204 €204 €204 €204 €204 €204 €204 €204 €204WIRED CONTROLLER RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4HRP Code 623194 623194 623194 623194 623194 623194 623194 623194 623194 623194LIST <strong>Price</strong> €86 €86 €86 €86 €86 €86 €86 €86 €86 €86OUTDOOR UNIT SRC40ZJX-S SRC50ZJX-S SRC60ZJX-S FDC71VNX FDC100VN FDC125VN FDC140VN FDC100VS (3 phase) FDC125VS (3 phase) FDC140VS (3 phase)HRP Code 625468 625478 625488 628060 628069 628101 628133 628085 628117 628149LIST <strong>Price</strong> €1,112 €1,391 €1,548 €2,057 €2,409 €2,603 €2,999 €2,409 €2,603 €2,999HRP SYSTEM Code 622068 622082 622088 622092 622098 622108 622118 622102 622112 622128SYSTEM LIST <strong>Price</strong> €2,125 €2,410 €2,673 €3,280 €3,812 €4,234 €4,853 €3,812 €4,234 €4,853Cooling (Nominal) kW 4 5 5.6 7.1 10 12.5 14 10 12.5 14Cooling Range kW 1.1 to 4.7 1.1 to 5.6 1.1 to 6.3 3.2 to 8.0 4.0 to 11.2 5.0 to 14.0 5.0 to 14.5 4.0 to 11.2 5.0 to 14.0 5.0 to 14.5UK Cooling Nom kW 3.8 4.8 5.4 6.7 9.4 11.8 12.7 9.4 11.8 12.7UK Sensible Cooling Nom kW 3.3 3.8 4.6 5.4 7.1 8.5 9.4 7.1 8.5 9.4E.E.R (Energy Label) 4.30 (A) 3.88 (A) 3.68 (A) 3.48 (A) 3.62 (A) 3.09 (B) 2.81 (C) 3.62 (A) 3.09 (B) 2.81 (C)Heating (Nominal) kW 4.5 5.4 6.7 8 11.2 14 16 11.2 14 16Heating Range kW 0.6 to 5.4 0.6 to 6.3 0.6 to 7.1 3.6 to 9.0 4.0 to 12.5 4.0 to 16.0 4.0 to 16.5 4.0 to 12.5 4.0 to 16.0 4.0 to 16.5C.O.P (Energy Label) 4.25 (A) 4.19 (A) 3.94 (A) 4.12 (A) 4.09 (A) 3.71 (A) 3.50 (B) 4.09 (A) 3.71 (A) 3.50 (B)INDOOR UNITExterior Dimensions (H x W x D) Unit mm 246 x 840 x 840 246 x 840 x 840 246 x 840 x 840 246 x 840 x 840 298 x 840 x 840 298 x 840 x 840 298 x 840 x 840 298 x 840 x 840 298 x 840 x 840 298 x 840 x 840Panel mm 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950Net Weight Unit (Fascia Panel) kg 22 (5.5) 22 (5.5) 24 (5.5) 24 (5.5) 27 (5.5) 27 (5.5) 27 (5.5) 27 (5.5) 27 (5.5) 27 (5.5)Air Volume (L - M - H -EH)* m3/s 0.23 - 0.27 - 0.30 - 0.33 0.23 - 0.27 - 0.30 - 0.33 0.23 - 0.27 - 0.30 - 0.33 0.28 - 0.32 - 0.35 - 0.47 0.33 - 0.40 - 0.45 - 0.62 0.38 - 0.45 - 0.50 - 0.62 0.38 - 0.45 - 0.50 - 0.62 0.33 - 0.40 - 0.45 - 0.62 0.38 - 0.45 - 0.50 - 0.62 0.38 - 0.45 - 0.50 - 0.62Sound Pressure Level (L / M /H / EH) dB(A) 30 / 31 / 33 / 39 30 / 31 / 33 / 39 30 / 31 / 33 / 39 31 / 33 / 35 / 46 35 / 37 / 40 / 51 37 / 40 / 42 / 51 38 / 41 / 43 / 51 35 / 37 / 40 / 51 37 / 40 / 42 / 51 38 / 41 / 43 / 51OUTDOOR UNITExterior Dimensions (H x W x D) mm 640 x 800(+71) x 290 640 x 800(+71) x 290 640 x 800(+71) x 290 750 x 880(+88) x 340 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370Net Weight kg 45 45 45 60 81 81 81 83 83 83Sound Pressure Level dB(A) 50 54 54 51 49 51 51 49 51 51ELECTRICAL DATAPower Source Rating MCB A 16 20 20 25 32 32 32 20 per phase 20 per phase 20 per phaseMains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz 415V/3ph/50HzInterconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + ERunning Current - Cooling Nom (Max) A 4.1 (12) 5.7 (15) 7.0 (15) 9.1 (24) 12.1 (24) 17.6 (24) 22 (24) 4.2 (15) per phase 5.9 (15) per phase 7.4 (15) per phaseRunning Current - Heating Nom (Max) A 5.2 (12) 5.7 (15) 8.2 (15) 8.7 (24) 12 (24) 16.6 (24) 20.2 (24) 4.2 (15) per phase 5.5 (15) per phase 6.7 (15) per phasePower Input - Cooling Nom kW 0.93 1.29 1.52 2.04 2.76 4.05 4.98 2.76 4.05 4.98Power Input - Heating Nom kW 1.06 1.29 1.7 1.94 2.74 3.77 4.57 2.74 3.77 4.57Start Current A 5 5 5 5 5 5 5 5 per phase 5 per phase 5 per phaseINSTALLATION/REFRIGERANTRef. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52)Gas 1/2” (12.7) 1/2” (12.7) 1/2” (12.7) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88)Ref. Max Piping Length m 30 30 30 50 50 50 50 50 50 50Vertical Height Difference (Max)- Outdoor Unit Above Indoor Unit m 20 20 20 30 30 30 30 30 30 30- Outdoor Unit Below Indoor Unit m 20 20 20 15 15 15 15 15 15 15Refrigerant Amount Precharged kg 1.5 1.5 1.5 2.95 3.8 3.8 3.8 3.8 3.8 3.8- For Pipe Length Up To m 15 15 15 30 30 30 30 30 30 30Additional Refrigerant g/m 20 20 20 60 60 60 60 60 60 60NEWPipe length up to 100mon Hyper Systems 100, 125, 140FDT Hyper 1-Phase (3ph - p.o.a.)FDT100VD FDT125VD FDT140VD628460 628476 628492€1,113 €1,341 €1,564T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E623209 623209 623209€204 €204 €204RC-E4 RC-E4 RC-E4623194 623194 623194€86 €86 €86FDC100VNX FDC125VNX FDC140VNX628205 628185 628195€2,818 €3,097 €3,569622095 622946 622951€4,221 €4,728 €5,42310 12.5 144.0 to 11.2 5.0 to 14.0 5.0 to 16.09.5 11.8 13.28.3 9.6 10.24.00 (A) 3.81 (A) 3.34 (A)11.2 14 164.0 to 12.5 4.0 to 17.0 4.0 to 18.04.34 (A) 4.08 (A) 3.81 (A)298 x 840 x 840 298 x 840 x 840 298 x 840 x 84035 x 950 x 950 35 x 950 x 950 35 x 950 x 95027 (5.5) 27 (5.5) 27 (5.5)0.33 - 0.40 - 0.45 - 0.62 0.38 - 0.45 - 0.50 - 0.62 0.38 - 0.45 - 0.50 - 0.6235 / 37 / 40 / 51 37 / 40 / 42 / 51 38 / 41 / 43 / 511300 x 970 x 370 1300 x 970 x 370 1300 x 970 x 370105 105 10550 50 5232 32 32230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz3 + E 3 + E 3 + E11.1 (24) 14.6 (24) 18.6 (26)11.4 (24) 15.2 (24) 18.6 (26)2.5 3.28 4.192.58 3.43 4.25 per phase 5 per phase 5 per phase3/8” (9.52) 3/8” (9.52) 3/8” (9.52)5/8” (15.88) 5/8” (15.88) 5/8” (15.88)100 100 10030 30 3015 15 154.5 4.5 4.530 30 3060 60 60FDT MULTI SPLIT Systems up to 25kWInstallation Accessories -• Copper Tube• Pipe Supports• Condensate Pumps & Hose• Cables- please see P42RC-E4 Remote Controller includes internal temperaturesensor, which can be used as an alternative to the unitreturn air sensor.Selling Category - BAccessoriesHRP Code6-Way Adaptor for Timeclock & BMS 633086 €17<strong>List</strong> <strong>Price</strong>Remote Controller & Receiver Kit 623203 €175Network Adaptor SC-ADN-E 623384 €127Space Collar - for restricted ceiling height - FDT Cassettes onlyHRP Code<strong>List</strong> <strong>Price</strong>50mm height 629802 €320100mm height 629818 €357150mm height 629826 €383Condensing Unit Drain Kit- please refer to P24• Insulation• Wall Brackets• IsolatorsTECHNICAL NOTESGroup Control is possible (up to 16 systems) using oneRC-E4 Remote Controller.Elbow & Grometts 626990 €11* If wireless remote controller is used, only 3 fan speeds are available: LOW/MED/HIGH.www.3dair .co.uk14 15


FDEN Ceiling Inverter Systems• Wired Controller standard, Infra-red option• Slim design - 210mm on most models• Low ambient operation to -15ºC• Refrigerant charged up to 30m pipe lengthFDEN Ceiling Hyper Inverter SystemsNEWPipe length up to 100mon Hyper Systems 100, 125, 140Selling Category -BFDEN 1-Phase SystemsFDEN 3-Phase SystemsINDOOR UNIT FDEN40VD FDEN50VD FDEN60VD FDEN71VD FDEN100VD FDEN125VD FDEN140VD FDEN100VD FDEN125VD FDEN140VDHRP Code 628308 628316 628324 628332 628340 628348 628356 628340 628348 628356LIST <strong>Price</strong> €859 €871 €964 €1,116 €1,301 €1,755 €2,020 €1,301 €1,755 €2,020WIRED CONTROLLER RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4HRP Code 623194 623194 623194 623194 623194 623194 623194 623194 623194 623194LIST <strong>Price</strong> €86 €86 €86 €86 €86 €86 €86 €86 €86 €86OUTDOOR UNIT SRC40ZJX-S SRC50ZJX-S SRC60ZJX-S FDC71VNX FDC100VN FDC125VN FDC140VN FDC100VS (3 phase) FDC125VS (3 phase) FDC140VS (3 phase)HRP Code 625468 625478 625488 628060 628069 628101 628133 628085 628117 628149LIST <strong>Price</strong> €1,112 €1,391 €1,548 €2,057 €2,409 €2,603 €2,999 €2,409 €2,603 €2,999(option)FDEN Hyper 1-Phase (3ph - p.o.a.)FDEN100VD FDEN125VD FDEN140VD628340 628348 628356€1,301 €1,755 €2,020RC-E4 RC-E4 RC-E4623194 623194 623194€86 €86 €86FDC100VNX FDC125VNX FDC140VNX628205 628185 628195€2,818 €3,097 €3,569FDEN MULTI SPLIT Systems up to 25kW- please refer to P24HRP SYSTEM Code 622002 622008 622012 622018 622028 622038 622048 622032 622042 622052SYSTEM LIST <strong>Price</strong> €2,057 €2,348 €2,598 €3,259 €3,796 €4,444 €5,105 €3,796 €4,444 €5,105Cooling (Nominal) kW 4 5 5.6 7.1 10 12.5 14 10 12.5 14Cooling Range kW 1.1 to 4.7 1.1 to 5.6 21.1 to 6.3 3.2 to 8.0 4.0 to 11.2 5.0 to 14.0 5.0 to 14.5 4.0 to 11.2 5.0 to 14.0 5.0 to 14.5UK Cooling Nom kW 3.8 4.8 5.4 6.7 9.4 11.8 12.7 9.4 11.8 12.7UK Sensible Cooling Nom kW 3 3.3 4.6 5.1 6.8 8.2 8.5 6.8 8.2 8.5E.E.R (Energy Label) 3.92 (A) 3.27 (B) 3.15 (B) 3.36 (A) 3.51 (A) 2.80 (D) 2.41 (E) 3.51 (A) 2.80 (D) 2.41 (E)Heating (Nominal) kW 4.5 5.4 6.7 8 11.2 14 16 11.2 14 16Heating Range kW 0.6 to 5.4 2.5 to 6.3 0.6 to 7.1 3.6 to 9.0 4.0 to 12.5 4.0 to 16.0 4.0 to 16.5 4.0 to 12.5 4.0 to 16.0 4.0 to 16.5C.O.P (Energy Label) 4.09 (A) 3.70 (A) 3.58 (B) 3.79 (A) 3.77 (A) 3.43 (B) 3.25 (C) 3.77 (A) 3.43 (B) 3.25 (C)INDOOR UNITExterior Dimensions (H x W x D) mm 210 x 1070 x 690 210 x 1070 x 690 210 x 1320 x 690 210 x 1320 x 690 250 x1620 x 690 250 x 1620 x 690 250 x 1620 x 690 250 x1620 x 690 250 x 1620 x 690 250 x 1620 x 690Net Weight kg 28 28 37 37 49 49 49 49 49 49Air Volume* (L - M - H -EH) m3/s 0.12 - 0.15 - 0.18 - 0.22 0.12 - 0.15 - 0.18 - 0.22 0.20 - 0.23 - 0.30 - 0.37 0.20 - 0.23 - 0.30 - 0.37 0.35 - 0.38 - 0.43 - 0.47 0.38 - 0.43 - 0.48 - 0.53 0.38 - 0.43 - 0.48 - 0.53 0.35 - 0.38 - 0.43 - 0.47 0.38 - 0.43 - 0.48 - 0.53 0.38 - 0.43 - 0.48 - 0.53Sound Pressure Level (L / M /H / EH) dB(A) 37 / 38 / 39 / 46 37 / 38 / 39 / 46 38 / 39 / 41 / 50 38 / 39 / 41 / 51 39 / 41 / 44 / 46 43 / 44 / 46 / 50 43 / 44 / 46 / 50 39 / 41 / 44 / 46 43 / 44 / 46 / 50 43 / 44 / 46 / 50OUTDOOR UNITExterior Dimensions (H x W x D) mm 640 x 800(+71) x 290 640 x 800(+71) x 290 640 x 800(+71) x 290 750 X 880(+88) X 340 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370Net Weight kg 45 45 45 60 81 81 81 83 83 83Sound Pressure Level dB(A) 50 54 54 51 49 51 51 49 51 51ELECTRICAL DATAPower Source Rating MCB A 16 20 20 25 32 32 32 20 per phase 20 per phase 20 per phaseMains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz 415V/3ph/50HzInterconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + ERunning Current - Cooling Nom (Max) A 4.7 (12) 7.1 (14) 8.7 (14) 9.4 (17) 12.5 (24) 19.5 (24) 25.6 (26) 4.2 (15) per phase 6.8 (15) per phase 8.6 (15) per phaseRunning Current - Heating Nom (Max) A 5.1 (12) 7.0 (14) 9.4 (14) 9.4 (17) 13 (24) 17.9 (24) 22.1 (26) 4.3 (15) per phase 6.3 (15) per phase 7.2 (15) per phasePower Input - Cooling Nom kW 1.02 1.53 1.78 2.11 2.85 4.45 5.8 2.85 4.45 5.8Power Input - Heating Nom kW 1.1 1.46 1.87 2.11 2.97 4.08 4.92 2.97 4.08 4.92Start Current A 5 5 5 5 5 5 5 5 per phase 5 per phase 5 per phaseINSTALLATION/REFRIGERANTRef. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52)Gas 1/2” (12.7) 1/2” (12.7) 1/2” (12.7) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88)Ref. Max Piping Length m 30 30 30 50 50 50 50 50 50 50Vertical Height Difference (Max)- Outdoor Unit Above Indoor Unit m 20 20 20 30 30 30 30 30 30 30- Outdoor Unit Below Indoor Unit m 20 20 20 15 15 15 15 15 15 15Refrigerant Amount Precharged kg 1.5 1.5 1.5 2.95 3.8 3.8 3.8 3.8 3.8 3.8- For Pipe Length Up To m 15 15 15 30 30 30 30 30 30 30Additional Refrigerant g/m 20 20 20 60 60 60 60 60 60 60* If wireless remote controller is used, only 3 fan speeds are available: LOW/MED/HIGH.TECHNICAL NOTE: The indoor unit comes set-up for use with an IR controller.When using the RC-E4 or RCH-E3 wired controller, please disconnect the IRPCB from the AB connection on the indoor unit.622023 622956 622961€4,205 €4,938 €5,67510 12.5 144.0 to 11.2 5.0 to 14.0 5.0 to 16.09.5 11.8 13.26.8 8.2 8.73.57 (A) 3.24 (B) 2.81 (C)11.2 14 164.0 to 12.5 4.0 to 16.0 4.0 to 16.53.89 (A) 3.71 (A) 3.41 (B)250 x1620 x 690 250 x 1620 x 690 250 x 1620 x 69049 49 490.35 - 0.38 - 0.43 - 0.47 0.38 - 0.43 - 0.48 - 0.53 0.38 - 0.43 - 0.48 - 0.5339 / 41 / 44 / 46 43 / 44 / 46 / 50 43 / 44 / 46 / 501300 x 970 x 370 1300 x 970 x 370 1300 x 970 x 370105 105 10550 50 5232 32 32230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz3 + E 3 + E 3 + E12.4 (24) 17.1 (26) 22.1 (26)12.8 (24) 16.7 (26) 20.8 (26)2.8 3.86 4.982.88 3.77 4.6924 26 263/8” (9.52) 3/8” (9.52) 3/8” (9.52)5/8” (15.88) 5/8” (15.88) 5/8” (15.88)50 50 5030 30 3015 15 154.5 4.5 4.530 30 300 60 60Installation MaterialsAvailable from HRP <strong>Ltd</strong> UK,Tel: 0044 (0)1925 837 688• Copper Tube• Pipe Supports• Condensate Pumps & Hose• Cables- please see P42AccessoriesCondensing Unit Drain Kit• Insulation• Wall Brackets• IsolatorsTECHNICAL NOTESGroup Control is possible (up to 16 systems) using oneRC-E4 Remote Controller.RC-E4 Remote Controller includes internal temperaturesensor, which can be used as an alternative to the unitreturn air sensor.HRP Code6-Way Adaptor for Timeclock & BMS 633086 €17Remote Control Infrared RCN-E1R 632196 €86Elbow & Grometts 626990 €11<strong>List</strong> <strong>Price</strong>Network Adaptor SC-ADN-E 623384 €12716www.hrponline.co.uk17


FDUM Ducted Inverter Systems• Medium static horizontal ducted units• Condensate lift pump included• Option of bottom horizontal return air• Low ambient operation to -15ºC• Refrigerant charged up to 30m pipe lengthSee opposite pagefor Filters/FramesFDUM Ducted Hyper Inverter SystemsNEWPipe length up to 100mon Hyper Systems 100, 125, 140Selling Category -B FDUM 1-Phase Systems FDUM 3-Phase SystemsFDUM Hyper 1-Phase (3ph - p.o.a.)INDOOR UNIT FDUM50VD FDUM60VD FDUM71VD FDUM100VD FDUM125VD FDUM140VD FDUM100VD FDUM125VD FDUM140VDHRP Code 628508 628516 628524 628532 628540 628548 628532 628540 628548LIST <strong>Price</strong> €693 €775 €1,039 €1,453 €1,712 €1,728 €1,453 €1,712 €1,728WIRED CONTROLLER RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4HRP Code 623194 623194 623194 623194 623194 623194 623194 623194 623194LIST <strong>Price</strong> €86 €86 €86 €86 €86 €86 €86 €86 €86OUTDOOR UNIT SRC50ZJX-S SRC60ZJX-S FDC71VNX FDC100VN FDC125VN FDC140VN FDC100VS (3 phase) FDC125VS (3 phase) FDC140VS (3 phase)HRP Code 625478 625488 628060 628069 628101 628133 628085 628117 628149LIST <strong>Price</strong> €1,391 €1,548 €2,057 €2,409 €2,603 €2,999 €2,409 €2,603 €2,999FDUM100VD FDUM125VD FDUM140VD628532 628540 628548€1,453 €1,712 €1,728RC-E4 RC-E4 RC-E4623194 623194 623194€86 €86 €86FDC100VNX FDC125VNX FDC140VNX628205 628185 628195€2,818 €3,097 €3,569FDUM MULTI SPLIT Systems up to 25kW- please refer to P24HRP SYSTEM Code 622120 622138 622142 622148 622158 622168 622152 622162 622172SYSTEM LIST <strong>Price</strong> €2,170 €2,409 €3,182 €3,948 €4,401 €4,813 €3,948 €4,401 €4,813Cooling (Nominal) kW 5 5.6 7.1 10 12.5 14 10 12.5 14Cooling Range kW 1.1 to 5.6 1.1 to 6.3 3.2 to 8.0 4.0 to 11.2 5.0 to 14.0 5.0 to 14.5 4.0 to 11.2 5.0 to 14.0 5.0 to 14.5UK Cooling Nom kW 4.8 5.4 6.7 9.4 11.8 12.7 9.4 11.8 12.7UK Sensible Cooling Nom kW 3.7 4.4 5.2 7.8 9 9.4 7.8 9 9.4E.E.R (Energy Label) 3.29 (B) 3.09 (B) 3.32 (A) 3.57 (A) 3.10 (B) 2.83 (C) 3.57 (A) 3.10 (B) 2.83 (C) 3.57 (A)Heating (Nominal) kW 5.4 6.7 8 11.2 14 16 11.2 14 16Heating Range kW 2.5 to 6.3 3.1 to 7.1 3.6 to 9.0 4.0 to 12.5 4.0 to 16.0 4.0 to 16.5 4.0 to 12.5 4.0 to 16.0 4.0 to 16.5C.O.P (Energy Label) 3.83 (A) 3.42 (B) 3.70 (A) 4.04 (A) 3.68 (B) 3.26 (C) 4.04 (A) 3.68 (B) 3.26 (C)INDOOR UNITExterior Dimensions (H x W x D) mm 299 x 750 x 635 299 x 950 x 635 299 x 950 x 635 350 x 1370 x 635 350 x 1370 x 635 350 x 1370 x 635 350 x 1370 x 635 350 x 1370 x 635 350 x 1370 x 635External Static Pressure (Standard / Max) Pa 50 / 85 50 / 85 50 / 85 60 / 90 60 / 85 60 / 85 60 / 90 60 / 85 60 / 85No. Of Supply Air Spigots mm 2 x 200 3 x 200 3 x 200 4 x 200 4 x 200 4 x 200 4 x 200 4 x 200 4 x 200Net Weight kg 34 40 40 59 59 59 59 59 59Air Volume* (L - M - H -EH) m3/s 0.18 - 0.20 - 0.22 - 0.23 0.23 - 0.25 - 0.27 - 0.30 0.25 - 0.30 - 0.33 - 0.38 0.37 - 0.42 - 0.47 - 0.57 0.37 - 0.42 - 0.47 - 0.57 0.37 - 0.42 - 0.47 - 0.57 0.37 - 0.42 - 0.47 - 0.57 0.37 - 0.42 - 0.47 - 0.57 0.37 - 0.42 - 0.47 - 0.57Sound Pressure Level (L / M /H / EH) dB(A) 28 / 31 / 34 / 35 28 / 31 /34 / 38 29 / 32 / 35 / 38 32 / 35 / 37 / 41 32 / 36 / 38 / 41 32 / 36 / 38 / 41 32 / 35 / 37 / 41 32 / 36 / 38 / 41 32 / 36 / 38 / 41OUTDOOR UNITExterior Dimensions (H x W x D) mm 640 x 800(+71) x 290 640 x 800(+71) x 290 750 x 880(+88) x 340 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370Net Weight kg 45 45 60 81 81 81 83 83 83Sound Pressure Level dB(A) 54 54 51 49 51 51 49 51 51ELECTRICAL DATAPower Source Rating MCB A 20 20 25 32 32 32 20 per phase 20 per phase 20 per phaseMains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz 415V/3ph/50HzInterconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + ERunning Current - Cooling Nom (Max) A 6.7 (14) 8.2 (14) 9.5 (17) 12.5 (24) 18.3 (24) 23.2 (26) 4.2 (15) per phase 6.1 (15) per phase 7.6 (15) per phaseRunning Current - Heating Nom (Max) A 6.3 (14) 9.0 (14) 9.6 (17) 12.4 (24) 17.0 (24) 22.3 (26) 4.1 (15) per phase 5.7 (15) per phase 7.4 (15) per phasePower Input - Cooling Nom kW 1.52 1.81 2.14 2.8 4.03 4.95 2.8 4.03 4.95Power Input - Heating Nom kW 1.41 1.96 2.16 2.77 3.8 4.89 2.77 3.8 4.89Start Current A 5 5 5 5 5 5 5 per phase 5 per phase 5 per phaseINSTALLATION/REFRIGERANTRef. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52)Gas 1/2” (12.7) 1/2” (12.7) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88)Ref. Max Piping Length m 30 30 50 50 50 50 50 50 50Vertical Height Difference (Max)- Outdoor Unit Above Indoor Unit m 20 20 30 30 30 30 30 30 30- Outdoor Unit Below Indoor Unit m 15 15 15 15 15 15 15 15 15Refrigerant Amount Precharged kg 1.5 1.5 2.95 3.8 3.8 3.8 3.8 3.8 3.8- For Pipe Length Up To m 15 15 30 30 30 30 30 30 30Additional Refrigerant g/m 20 20 60 60 60 60 60 60 60* If wireless remote controller is used, only 3 fan speeds are available: LOW/MED/HIGH.Return Air Filter Kit Not included.622145 622966 622971€4,357 €4,895 €5,38310 12.5 144.0 to 11.2 5.0 to 14.0 5.0 to 16.09.5 11.8 13.27.8 9 9.63.68 (A) 3.45 (A) 3.23 (B)11.2 14 164.0 to 12.5 4.0 to 16.0 4.0 to 16.54.04 (A) 3.71 (A) 3.41 (B)350 x 1370 x 635 350 x 1370 x 635 350 x 1370 x 63560 / 90 60 / 85 60 / 854 x 200 4 x 200 4 x 20059 59 590.37 - 0.42 - 0.47 - 0.57 0.37 - 0.42 - 0.47 - 0.57 0.37 - 0.42 - 0.47 - 0.5732 / 35 / 37 / 41 32 / 36 / 38 / 41 32 / 36 / 38 / 411300 x 970 x 370 1300 x 970 x 370 1300 x 970 x 370105 105 10550 50 5232 32 32230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz3 + E 3 + E 3 + E12.1 (24) 16.1 (26) 19.3 (26)13.1 (24) 16.7 (26) 20.8 (26)2.72 3.62 4.342.95 3.77 4.695 5 53/8” (9.52) 3/8” (9.52) 3/8” (9.52)5/8” (15.88) 5/8” (15.88) 5/8” (15.88)100 100 10030 30 3015 15 154.5 4.5 4.530 30 3060 60 60Technical Note:When designing ductwork and filtration,always refer to manufacturer's Fan Curves.Installation MaterialsAvailable from HRP <strong>Ltd</strong> UK,Tel: 0044 (0)1925 837 688• Copper Tube• Pipe Supports• Condensate Pumps & Hose• Cables- please see P42TECHNICAL NOTES• Insulation• Wall Brackets• IsolatorsGroup Control is possible (up to 16 systems) using oneRC-E4 Remote Controller.RC-E4 Remote Controller includes internal temperaturesensor, which can be used as an alternative to the unitreturn air sensor.AccessoriesHRP Code <strong>List</strong> <strong>Price</strong>6-Way Adaptor for Timeclock & BMS 633086 €17Remote Control (IR) & Receiver Kit 623452 €218Network Adaptor SC-ADN-E 623384 €127Filter kit FDUM 50 UM-FL1E 624312 €121Filter kit FDUM 60 - 71 UM-FL2E 624314 €121Filter kit FDUM 100 - 140 UM-FL3E 624316 €12118www.3dair .co.uk19


FDU Ducted High Static Inverter Systems• High static (up to 200Pa) horizontal ducted units• Gravity condensate drain• Large capacity systems up to 25kW cooling• Low ambient operation to - 15ºC• Refrigerant charged up to 30m pipe lengthFDU Ducted Hyper Inverter SystemsNEWPipe length up to 100mon Hyper Systems 100, 125, 140Selling Category -BFDU 1-Phase SystemsFDU 3-Phase SystemsINDOOR UNIT FDU71VD FDU100VD FDU125VD FDU140VD FDU100VD FDU125VD FDU140VD FDU200VD FDU250VDHRP Code 628604 628622 628630 628638 628622 628630 628638 628588 628596LIST <strong>Price</strong> €1,025 €1,311 €1,658 €1,662 €1,311 €1,658 €1,662 €3,555 €3,926WIRED CONTROLLER RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4HRP Code 623194 623194 623194 623194 623194 623194 623194 623194 623194LIST <strong>Price</strong> €86 €86 €86 €86 €86 €86 €86 €86 €86OUTDOOR UNIT FDC71VNX FDC100VN FDC125VN FDC140VN FDC100VS (3 phase) FDC125VS (3 phase) FDC140VS (3 phase) FDC200VS (3 phase) FDC250VS (3 phase)HRP Code 628060 628069 628101 628133 628085 628117 628149 628165 628181LIST <strong>Price</strong> €2,057 €2,409 €2,603 €2,999 €2,409 €2,603 €2,999 €4,187 €4,596HRP SYSTEM Code 622881 622886 622896 622906 622891 622901 622911 622571 622576SYSTEM LIST <strong>Price</strong> €3,116 €3,806 €4,347 €4,747 €3,806 €4,347 €4,747 €7,828 €8,608Cooling (Nominal) kW 7.1 10 12.5 14 10 12.5 14 20 25Cooling Range kW 3.2 to 8.0 4.0 to 11.2 5.0 to 14.0 5.0 to 14.5 4.0 to 11.2 5.0 to 14.0 5.0 to 14.5 7.0 to 22.4 10.0 to 28.0UK Cooling Nom kW 6.7 9.4 11.8 12.7 9.4 11.8 12.7 19.1 23.8UK Sensible Cooling Nom kW 5.7 8 10 10.3 8 10 10.3 14.2 18.2E.E.R (Energy Label) 3.30 (A) 3.47 (A) 3.09 (B) 2.83 (C) 3.47 (A) 3.09 (B) 2.83 (C) 3.03 (B) 2.52 (E)Heating (Nominal) kW 8 11.2 14 16 11.2 14 16 22.4 28Heating Range kW 3.6 to 9.0 4.0 to 12.5 4.0 to 16.0 4.0 to 16.5 4.0 to 12.5 4.0 to 16.0 4.0 to 16.5 7.6 to 25.0 9.5 to 31.5C.O.P (Energy Label) 3.72 (A) 3.75 (A) 3.69 (B) 3.61 (B) 3.75 (A) 3.69 (B) 3.61 (B) 3.68 (B) 3.29 (C)INDOOR UNITExterior Dimensions (H x W x D) mm 297 x 850 x 650 350 x 1370 x 650 350 x 1370 x 650 350 x 1370 x 650 350 x 1370 x 650 350 x 1370 x 650 350 x 1370 x 650 360 x 1570 x 830 360 x 1570 x 830External Static Pressure (Standard / Max) Pa 50 / 130 50 / 130 50 / 130 50 / 130 50 / 130 50 / 130 50 / 130 100 / 200 100 / 200Size Of Supply Air Spigot (H x W) mm 244 x 848 297 x 1368 297 x 1368 297 x 1368 297 x 1368 297 x 1368 297 x 1368 250 x 1450 250 x 1450Net Weight kg 40 63 63 63 63 63 63 92 92Air Volume (L - H) m3/s 0.28 - 0.33 0.45 - 0.57 0.56 - 0.70 0.56 - 0.70 0.45 - 0.57 0.56 - 0.70 0.56 - 0.70 0.85 1.13Sound Pressure Level (L / H) dB(A) 37 / 41 37 / 42 38 / 43 38 / 43 37 / 42 38 / 43 38 / 43 51 51OUTDOOR UNITExterior Dimensions (H x W x D) mm 750 x 880(+88) x 340 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 1300 x 970 x 370 1505 x 970 x 370Net Weight kg 60 81 81 81 83 83 83 122 140Sound Pressure Level dB(A) 51 49 51 51 49 51 51 57 58ELECTRICAL DATAPower Source Rating MCB A 25 32 32 32 20 per phase 20 per phase 20 per phase 32 per phase 32 per phaseMains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz 415V/3ph/50HzInterconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + ERunning Current - Cooling Nom (Max) A 9.6 (17) 12.7 (25) 17.8 (27) 21.7 (28) 4.3 (15) per phase 6.1 (15) per phase 7.4 (15) per phase 10.8 (24) per phase 15.7 (27) per phaseRunning Current - Heating Nom (Max) A 9.5 (17) 13.1 (25) 16.6 (27) 19.5 (28) 4.4 (15) per phase 5.6 (15) per phase 6.6 (15) per phase 10.2 (24) per phase 14.4 (27) per phasePower Input - Cooling Nom kW 2.15 2.88 4.04 4.95 2.9 4.04 4.95 6.59 9.91Power Input - Heating Nom kW 2.15 2.99 3.79 4.43 3.0 3.79 4.43 6.08 8.5Start Current A 5 5 5 5 5 per phase 5 per phase 5 per phase 5 per phase 5 per phaseINSTALLATION/REFRIGERANTRef. Piping Size o.d ins (mm) Liquid 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 40m = 1/2" 1/2”Gas 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 35m = 11/8" 1 1/8"Ref. Max Piping Length m 50 50 50 50 50 50 50 70 70Vertical Height Difference (Max)- Outdoor Unit Above Indoor Unit m 30 30 30 30 30 30 30 30 30- Outdoor Unit Below Indoor Unit m 15 15 15 15 15 15 15 15 15Refrigerant Amount Precharged kg 2.95 3.8 3.8 3.8 3.8 3.8 3.8 5.4 7.2- For Pipe Length Up To m 30 30 30 30 30 30 30 30 (15 if 1/2" & 1 1/8") 30Additional Refrigerant g/m 60 60 60 60 60 60 60 60 (120 if 1/2" & 1 1/8") 120FDU Hyper 1-Phase (3ph - p.o.a.)FDU100VD FDU125VD FDU140VD628622 628630 628638€1,311 €1,658 €1,662RC-E4 RC-E4 RC-E4623194 623194 623194€86 €86 €86FDC100VNX FDC125VNX FDC140VNX628205 628185 628195€2,818 €3,097 €3,569622883 622893 622903€4,215 €4,841 €5,31710 12.5 144.0 to 11.2 5.0 to 14.0 5.0 to 16.09.5 11.8 13.28 10 10.53.60 (A) 3.63 (A) 3.33 (A)11.2 14 164.0 to 12.5 4.0 to 16.0 4.0 to 16.53.86 (A) 3.81 (A) 3.72 (A)350 x 1370 x 650 350 x 1370 x 650 350 x 1370 x 65050 / 130 50 / 130 50 / 130297 x 1368 297 x 1368 297 x 136863 63 630.45 - 0.57 0.56 - 0.70 0.56 - 0.7037 / 42 38 / 43 38 / 43845 x 970 x 370 1370 x 970 x 370 1370 x 970 x 370105 105 10550 50 5232 40 40230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz3 + E 3 + E 3 + E12.3 (25) 15.3 (29) 18.6 (30)12.9 (25) 16.3 (29) 19.1 (30)2.78 3.44 4.22.9 3.67 4.35 5 53/8” (9.52) 3/8” (9.52) 3/8” (9.52)5/8” (15.88) 5/8” (15.88) 5/8” (15.88)100 100 10030 30 3015 15 154.5 4.5 4.530 30 3060 60 60Technical Note:FDU Ducted units require gravity condensate drain.Please refer to MHI Technical Manual regarding drainsizes and requirement for traps.When designing ductwork and filtration, refer tomanufacturer's Fan Curves.Installation MaterialsAvailable from HRP <strong>Ltd</strong> UK,Tel: 0044 (0)1925 837 688• Copper Tube• Pipe Supports• Condensate Pumps & Hose• Cables- please see P42AccessoriesCondensing Unit Drain Kit• Insulation• Wall Brackets• IsolatorsTECHNICAL NOTESGroup Control is possible (up to 16 systems) using oneRC-E4 Remote Controller.RC-E4 Remote Controller includes internal temperaturesensor, which can be used as an alternative to the unitreturn air sensor.HRP Code6-Way Adaptor for Timeclock & BMS 633086 €17Elbow & Grometts 626990 €11<strong>List</strong> <strong>Price</strong>Remote Control & Receiver Kit 623452 €218Network Adaptor SC-ADN-E 623384 €127Fan control kit for FDU U-FCR 623387 €219Fan control kit for FDU U-FCRA 623388 €219Filter kit FDU200-250 624196 €18920www.hrponline.co.uk21


FDF Floor Vertical Inverter SystemsFDF Hyper Inverter Systems• Stylish vertical cabinet type indoor units• Integral RC-E4 multi function Controller• Small footprint - high capacity up to 14kW cooling• Low ambient operation to -15ºCSelling Category -BFDF 1-Phase SystemsController includedwith FDFFDF 3-Phase SystemsINDOOR UNIT incl. Controller FDF71VD FDF100VD FDF125VD FDF140VD FDF100VD FDF125VD FDF140VDHRP Code 628680 628685 628690 628695 628685 628690 628695LIST <strong>Price</strong> €1,842 €1,942 €2,077 €2,260 €1,942 €2,077 €2,260OUTDOOR UNIT FDC71VNX FDC100VN FDC125VN FDC140VN FDC100VS (3 phase) FDC125VS (3 phase) FDC140VS (3 phase)HRP Code 628060 628069 628101 628133 628085 628117 628149LIST <strong>Price</strong> €2,057 €2,409 €2,603 €2,999 €2,409 €2,603 €2,999NEWPipe length up to 100mon Hyper Systems 100, 125, 140FDF Hyper 1-Phase (3ph - p.o.a.)FDF100VD FDF125VD FDF140VD628685 628690 628695€1,942 €2,077 €2,260FDC100VNX FDC125VNX FDC140VNX628205 628185 628195€2,818 €3,097 €3,569FDF MULTI SPLIT Systems up to 25kWHRP SYSTEM Code 624398 624403 624408 624413 624418 624423 624428SYSTEM LIST <strong>Price</strong> €3,899 €4,351 €4,680 €5,259 €4,350 €4,680 €5,259Cooling (Nominal) kW 7.1 10 12.5 14 10 12.5 14Cooling Range kW 3.2 to 8.0 4.0 to 11.2 5.0 to 14.0 5.0 to 14.5 4.0 to 11.2 5.0 to 14.0 5.0 to 14.5UK Cooling NomkWUK Sensible Cooling NomkWE.E.R (Energy Label) 3.21 (B) 3.21 (B) 2.84 (C) 2.72 (D) 3.21 (B) 2.84 (C) 2.72 (D)Heating (Nominal) kW 8 11.2 14 16 11.2 14 16Heating Range kW 3.6 to 9.0 4.0 to 12.5 4.0 to 16.0 4.0 to 16.5 4.0 to 12.5 4.0 to 16.0 4.0 to 16.5C.O.P (Energy Label) 3.62 (B) 3.61 (B) 3.21 (C) 3.01 (D) 3.61 (B) 3.21 (C) 3.01 (D)INDOOR UNITExterior Dimensions (H x W x D) mm 1850 x 600 x 320 1850 x 600 x 320 1850 x 600 x 320 1850 x 600 x 320 1850 x 600 x 320 1850 x 600 x 320 1850 x 600 x 320Net Weight kg 49 52 52 52 52 52 52Air Volume (L - M - H) m3/s 0.23 - 0.27 - 0.30 0.32 - 0.38 - 0.43 0.32 - 0.38 - 0.43 0.32 - 0.38 - 0.43 0.32 - 0.38 - 0.43 0.32 - 0.38 - 0.43 0.32 - 0.38 - 0.43Sound Pressure Level** (L / M / H) dB(A) 33 / 35 / 39 44 / 48 / 50 44 / 48 / 50 44 / 48 / 50 44 / 48 / 50 44 / 48 / 50 44 / 48 / 50OUTDOOR UNITExterior Dimensions (H x W x D) mm 750 x 880(+88) x 340 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370Net Weight kg 60 81 81 81 83 83 83Sound Pressure Level dB(A) 51 49 51 51 49 51 51ELECTRICAL DATAPower Source Rating MCB A 25 32 32 32 20 per phase 20 per phase 20 per phaseMains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz 415V/3ph/50HzInterconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + ERunning Current - Cooling Nom (Max) A tba (17) tba (24 tba (24) tba (24) tba (15) per phase tba (15) per phase tba (15) per phaseRunning Current - Heating Nom (Max) A tba (15) per phase tba (15) per phase tba (15) per phasePower Input - Cooling Nom kW 2.21 3.12 4.4 5.15 3.12 4.4 5.15Power Input - Heating Nom kW 2.21 3.1 4.36 5.31 3.1 4.36 5.31Start Current A 5 5 5 5 5 per phase 5 per phase 5 per phaseINSTALLATION/REFRIGERANTRef. Piping Size o.d ins (mm) Liquid 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52)Gas 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88)Ref. Max Piping Length m 50 50 50 50 50 50 50Vertical Height Difference (Max)- Outdoor Unit Above Indoor Unit m 30 30 30 30 30 30 30- Outdoor Unit Below Indoor Unit m 15 15 15 15 15 15 15Refrigerant Amount Precharged kg 2.95 3.8 3.8 3.8 3.8 3.8 3.8- For Pipe Length Up To m 30 30 30 30 30 30 30Additional Refrigerant g/m 60 60 60 60 60 60 60624436 624441 624446€4,760 €5,174 €5,82910 12.5 144.0 to 11.2 5.0 to 14.0 5.0 to 16.03.53 (A) 3.21 (B) 3.01 (B)11.2 14 164.0 to 12.5 4.0 to 17.0 4.0 to 18.03.68 (B) 3.61 (B) 3.41 (B)1850 x 600 x 320 1850 x 600 x 320 1850 x 600 x 32052 52 520.32 - 0.38 - 0.43 0.32 - 0.38 - 0.43 0.32 - 0.38 - 0.4344 / 48 / 50 44 / 48 / 50 44 / 48 / 501300 x 970 x 370 1300 x 970 x 370 1300 x 970 x 370105 105 10550 50 5232 32 32230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz3 + E 3 + E 3 + Etba (24) tba (26) tba (26)tba (24) tba (26) tba (26)2.83 3.89 4.653.04 3.88 4.695 5 53/8” (9.52) 3/8” (9.52) 3/8” (9.52)5/8” (15.88) 5/8” (15.88) 5/8” (15.88)100 100 10030 30 3015 15 154.5 4.5 4.530 30 3060 60 60Installation MaterialsAvailable from HRP <strong>Ltd</strong> UK,Tel: 0044 (0)1925 837 688• Copper Tube• Pipe Supports• Condensate Pumps & Hose• Cables- please see P42FDF - only Twin Systemsavailable for FDF -See page 24• Insulation• Wall Brackets• IsolatorsTECHNICAL NOTESGroup Control is possible (up to 16 systems) using oneRC-E4 Remote Controller.RC-E4 Remote Controller includes internal temperaturesensor, which can be used as an alternative to the unitreturn air sensor.AccessoriesHRP Code <strong>List</strong> <strong>Price</strong>6-Way Adaptor for Timeclock & BMS 633086 €17Remote Control & Receiver Kit 623452 €218Network Adaptor SC-ADN-E 623384 €127New for <strong>2011</strong>FDF Vertical Floor StandingUnits up to 14kW Cooling,16kW Heating22 www.3dair .co.uk23


FD Inverter Multi SystemsFD Hyper Inverter Multi SystemsThe System Codes and <strong>Price</strong>s below include IndoorUnits, Outdoor Unit, and the required Pipe Kits, andRemote Controller. Wall Mounted SRK-ZJX-S Twin andTriple Systms also include one SC-BIKNE Adaptor foreach indoor unit.Pipe length up to 100mon FDC100, 125, 140 VNX and VSX (3ph)Outdoor Unit Standard Inverter Indoor Unit Cassette Compact Ceiling Ducted exc. Wall FloorCassette Suspended RA Filter Kit (ZJX-S) incl. StandingSC-BIKN-E inc. RC-E4Model Cooling Range (kW) Heating Range (kW) Ref FDT FDTC FDEN FDUM SRK FDF4.0 to 11.0 4.0 to 12.5€4,514 €4,544 €4,390 €4,034 €4,720 -FDC100VNTWIN (1 x DIS-WA1)50 + 50622592 622808 622702 622648 622916 -1Ph *E.E.R (Energy Label) 3.40 (A) 3.52 (A) 3.21 (B) 3.21 (B) 3.62 (A) -C.O.P (Energy Label) 3.62 (B) 3.64 (B) 3.41 (B) 3.43 (B) 3.92 (A) -5.0 to 14.0 4.0 to 16.0€4,920 €4,880 €4,770 €4,392 €5,098FDC125VN1Ph *FDC140VN1Ph *FDC140VN1Ph *TWIN (1 x DIS-WA1)60 + 60622598 622510 622708 622652 622926-E.E.R (Energy Label) 3.16 (B) 2.34 (F) 2.96 (C) 2.80 (D) 2.94 (C) -C.O.P (Energy Label) 3.78 (A) 3.03 (D) 3.66 (B) 3.10 (D) 3.26 (C) -5.0 to 14.5 4.0 to 16.5€5,512 - €5,470 €5,316 - €6,836TWIN (1 x DIS-WA1)71 + 71622602 - 622712 622658 - 624330E.E.R (Energy Label) 3.10 (B) - 2.87 (C) 2.80 (D) - 2.71 (D)C.O.P (Energy Label) 3.49 (B) - 3.49 (B) 3.24 (C) - 3.19 (D)5.0 to 14.5 4.0 to 16.5€6,037 €6,082 €5,851 €5,317 €6,346 -TRIPLE (1 x DIS-TA1) when the differential of branch pipes is < 3m50 + 50 + 50622608 622812 622718 622662 622936 -E.E.R (Energy Label) 3.01 (B) 3.02 (B) 2.87 (C) 2.75 (D) 3.09 (B) -C.O.P (Energy Label) 3.46 (B) 3.54 (B) 3.49 (B) 3.18 (D) 3.95 (B) -7.0 to 22.4 7.6 to 25.0€7,060 - €7,028 €7,332 - €8,224FDC200VS **TWIN (1 x DIS-WB1)100 + 100622328 - 622332 622338 - 6243353PhE.E.R (Energy Label) 3.04 (B) - 3.09 (B) 2.92 (C) - 3.08C.O.P (Energy Label) 3.72 (A) - 3.75 (A) 3.33 (C) - 3.497.0 to 22.4 7.6 to 25.0€7,837 - €7,774 €7,543 - -FDC200VS ** TRIPLE (1 x DIS-TB1) when the differential of branch pipes is < 3m71 + 71 + 71622372 - 622378 622388 - -3PhE.E.R (Energy Label) 3.08 (B) - 3.13 (B) 2.91 (C) - -C.O.P (Energy Label) 3.66 (B) - 3.80 (A) 3.32 (C) - -7.0 to 22.4 7.6 to 25.0€8,464 €8,524 €8,216 - - -FDC200VS **QUAD (1 x DIS-WB1 & 2 x DIS-WA1)50 + 50 + 50 + 50622438 622508 622736 - - -3PhE.E.R (Energy Label) 3.04 (B) 2.73 (D) 2.69 (D) - - -C.O.P (Energy Label) 3.64 (B) 3.21 (C) 3.09 (D) - - -10.0 to 28.0 9.5 to 31.5€7,925 - €8,345 €8,259 - €8,903FDC250VSTWIN (1 x DIS-WB1)125 + 125622358 - 622362 622368 - 6243403PhE.E.R (Energy Label) 3.01 (B) - 2.77 (D) 2.69 (D) - 2.79 (D)C.O.P (Energy Label) 3.61 (B) - 3.48 (B) 3.35 (C) - 3.05 (D)10.0 to 28.0 9.5 to 31.5€9,297 €9,217 €8,997 - - -FDC250VSQUAD (1 x DIS-WB1 & 2 x DIS-WA1)60 + 60 + 60 + 60622458 622514 622462 - - -3PhE.E.R (Energy Label) 3.02 (B) 3.02 (B) 2.63 (D) - - -C.O.P (Energy Label) 3.64 (B) 3.54 (B) 3.22 (C) - - -* 3ph also available: FDC100VS 628085 FDC125VS 628117 FDC140VS 628149** If pipe length > 30m the liquid line must be changed to 1/2" and the additional refrigerant charge is 120g/mSystem prices include all branch kits & 1 x RC-E4 Wired Controller.Mix-match of indoor units: it is possible to connect cassette and ceiling suspended to the same system - poa24Outdoor Unit Hyper Inverter Indoor Unit Cassette Compact Ceiling Ducted exc. Wall FloorCassette Suspended RA Filter Kit (ZJX-S) incl. StandingSC-BIKN-E inc. RC-E4Model Cooling Range (kW) Heating Range (kW) Ref FDT FDTC FDEN FDUM SRK FDF3.2 to 8.0 3.6 to 9.0€4,146 €4,150 €4,014 - - -FDC71VNXTWIN (1 x DIS-WA1)40 + 40622588 622802 6226981PhE.E.R (Energy Label) 3.84 (A) 3.72 (A) 4.08 (A) - - -C.O.P (Energy Label) 4.02 (A) 3.85 (A) 4.35 (A) - - -4.0 to 11.2 4.0 to 12.5€4,923 €4,953 €4,799 €4,443 €5,129 -FDC100VNX1Ph *FDC125VNX1Ph *FDC140VNX1Ph *FDC140VNX1Ph *TWIN SYSTEMS - PIPE SIZINGTWIN (1 x DIS-WA1)50 + 50624451 624464 624474 624486 624343 -E.E.R (Energy Label) 3.40 (A) 3.52 (A) 3.21 (B) 3.21 (B) 3.62 (A) -C.O.P (Energy Label) 3.62 (B) 3.64 (B) 3.41 (B) 3.43 (B) 3.92 (A) -5.0 to 14.0 4.0 to 17.0€5,414 €5,374 €5,264 €4,886 €5,592 -TWIN (1 x DIS-WA1)60 + 60624454 624467 624477 624489 624347E.E.R (Energy Label) 3.16 (B) 2.34 (F) 2.96 (C) 2.80 (D) 2.94 (C) -C.O.P (Energy Label) 3.78 (A) 3.03 (D) 3.66 (B) 3.10 (D) 3.26 (C) -5.0 to 16.0 4.0 to 18.0€6,082 - €6,040 €5,886 - €7,406TWIN (1 x DIS-WA1)71 + 71624457 - 624480 624492 - 624355E.E.R (Energy Label) 3.10 (B) - 2.87 (C) 2.80 (D) - 2.90 (C)C.O.P (Energy Label) 3.49 (B) - 3.49 (B) 3.24 (C) - 3.22 (C)5.0 to 16.0 4.0 to 18.0€6,607 €6,652 €6,421 €5,887 €6,916 -TRIPLE (1 x DIS-TA1) when the differential of branch pipes is < 3m50 + 50 + 50624460 624470 624483 624495 624350 -E.E.R (Energy Label) 3.01 (B) 3.02 (B) 2.87 (C) 2.75 (D) 3.09 (B) -C.O.P (Energy Label) 3.46 (B) 3.54 (B) 2.87 (C) 3.18 (D) 3.95 (A) -* 3ph Hyper also available: FDC100VSX 628210 FDC125VSX 628190 FDC140VSX 628200If IR control is required please order 1 x RCN-KIT3-E (€218) in place of RC-E4 controller (€86)SYSTEM PRICES INCLUDE ALL BRANCH KITS & 1 x RC-E4 WIRED CONTROLLEROutdoor Unit Indoor Unit Main Pipes Branch PipesFDC71 40 + 40 3/8" 5/8" 3/8" 1/2"FDC100 50 + 50 3/8" 5/8" 3/8" 1/2"FDC125 60 + 60 3/8" 5/8" 3/8" 1/2"FDC140 71 + 71 3/8" 5/8" 3/8" 5/8"FDC200 100 + 100 Liquid


FD Multi Systems incl Hyper MultiWiring & addressingGroup control1 PHASE OUTDOOR UNITS3 PHASE OUTDOOR UNITSSYSTEM 0 OUTDOOR UNITSYSTEM 1 OUTDOOR UNITLNL1L2L3N1 2 3 EThe indoor units must beisolated locally usingcontacts with a minimumcurrent rating of 5 amps1 = LIVE2/2N = Neutral3 = SignalNB - 3 is a low voltagesignal wire and does notneed isolating.All electrical instalations should be completedin accordance to local authority regulationsWhen multi systems are controlled in a group (max16 indoor units) using a single remote controller, it isnecessary to set SW2 so each individual multi systemhas indoor units with the same address connected toit. eg 0-0-0, 1-1-1, 2-2-2.1 2N 3 E1 2N 3 E 1 2N 3 E 1 2N 3 EMaster Slave 1 Slave 2 Slave 3MasterSW2=0SlaveSW2=0SlaveSW2=0MasterSW2=1SlaveSW2=1SlaveSW2=1XYX Y X Y X YX YIndoor board address switchesMaster Slave 1 Slave 2 Slave 3SW5-1 OFF OFF ON ONSW5-2 OFF ON OFF ONThe Master/Slave address must be setSW5 as aboveRemote Controller RC-E4Remote Controller RC-E426 www.3dair .co.uk27


VRF heat pump (2-pipe) outdoor units KX6• Employs DC inverter compressors only• High energy efficiency (high C.O.P) cooling or heating for open plan areasMINI KX6 OUTDOOR UNITS 2-pipeModel 1phNominal Capacity (kW)Cooling HeatingNo. Of UnitsConnectableConnectableCapacityPower Source RatingD-Curve MCB230V/50Hz/1phRunning CurrentStart CurrentStart Current(per phase)Power Input (kW)Cooling HeatingPower Input (kW)Cooling HeatingDimensionsH x W x D (mm)DimensionsH x W x D (mm)Weight (kg)Weight (kg)Sound PressureLevel (dBA)FDC112KXEN6 11.2 12.5 1 to 6 90 - 168 25A 13.0A 5A 2.80 2.89 845 x 970 x 370 85 54 5.0 621405 €4,759FDC140KXEN6 14.0 16.0 1 to 8 112 - 210 32A 20.6A 5A 4.17 4.31 845 x 970 x 370 85 55 5.0 621415 €5,101FDC155KXEN6 15.5 16.3 1 to 8 124 - 233 32A 22.3A 5A 4.71 4.38 845 x 970 x 370 85 56 5.0 621425 €5,621Model 3phNominal Capacity (kW)Cooling HeatingOperating Range (Outdoor Air), Cooling -15ºC DB to 43ºC, Heating -20ºC WB to 15.5ºC WBNo. Of UnitsConnectableConnectableCapacityPower Source RatingD-Curve MCB415V/50Hz/3ph (TPNE)Running Current(per phase)Sound PressureLevel (dBA)FDC112KXES6 11.2 12.5 1 to 6 90 - 168 10A 4.3A 5A 2.80 2.89 845 x 970 x 370 87 54 5.0 621410 €4,759FDC140KXES6 14.0 16.0 1 to 8 112 - 210 16A 6.6A 5A 4.17 4.31 845 x 970 x 370 87 55 5.0 621420 €5,101FDC155KXES6 15.5 16.3 1 to 8 124 - 233 16A 7.1A 5A 4.71 4.38 845 x 970 x 370 87 56 5.0 621430 €5,621Factory RefCharge (kg)Factory RefCharge (kg)HRP CODEHRP CODE<strong>List</strong> <strong>Price</strong><strong>List</strong> <strong>Price</strong>COMPACT KX6 OUTDOOR UNITS 2-pipeModelNominal Capacity (kW)Cooling HeatingOperating Range (Outdoor Air), Cooling -15ºC DB to 43ºC, Heating -20ºC WB to 15.5ºC WBNo. Of UnitsConnectableConnectableCapacityPower Source RatingD-Curve MCB415V/50Hz/3ph (TPNE)Running Current(per phase)Start Current(per phase)Power Input (kW)Cooling HeatingDimensionsH x W x D (mm)Weight (kg)Sound PressureLevel (dBA)FDC224KXE6* 22.4 25.0 1 to 15 112 - 336 16A 9.0A 5A 5.60 6.03 1675 x 1080 x 480 221 58 11.5 621435 €8,923FDC280KXE6* 28.0 31.5 1 to 19 140 - 420 20A 12.3A 5A 8.09 8.21 1675 x 1080 x 480 221 60 11.5 621440 €9,870FDC335KXE6* 33.5 37.5 1 to 22 168 - 503 25A 15.0A 5A 9.82 10.12 1675 x 1080 x 480 224 61 11.5 621445 €11,799Factory RefCharge (kg)HRP CODE<strong>List</strong> <strong>Price</strong>VERTICAL KX6 OUTDOOR UNITS 2-pipeModelNominal Capacity (kW)Cooling HeatingNo. Of UnitsConnectableConnectableCapacityPower Source RatingD-Curve MCB415V/50Hz/3ph (TPNE)Running Current(per phase)Start Current(per phase)Power Input (kW)Cooling HeatingDimensionsH x W x D (mm)FDC400KXE6* 40.0 45.0 1 to 36 200 - 800 1 x 25A 17.9A 8A 11.27 11.73 1690 x 1350 x 720 317 60 11.5 621455 €13,743FDC450KXE6* 45.0 50.0 1 to 40 225 - 900 1 x 32A 19.9A 8A 12.97 13.10 1690 x 1350 x 720 317 62.5 11.5 621460 €16,830FDC504KXE6* 50.4 56.5 1 to 36 252 - 806 1 x 32A 23.1A 8A 14.73 15.12 2048 x 1350 x 720 341 62 11.5 621465 €18,251FDC560KXE6* 56.0 63.0 1 to 40 280 - 896 1 x 40A 25.7A 8A 16.79 16.79 2048 x 1350 x 720 341 63.5 11.5 621470 €18,981FDC615KXE6* 61.5 69.0 2 to 44 308 - 984 1 x 40A 30.3A 8A 20.37 18.48 2048 x 1350 x 720 355 64.0 11.5 621475 €21,961FDC680KXE6* 68.0 73.0 2 to 49 340 - 1088 1 x 50A 36.9A 8A 24.98 19.08 2048 x 1350 x 720 355 65.0 11.5 621480 €22,690(FDC335KXE6-K + FDC400KXE6) FDC735KXE6* 73.5 82.5 2 to 53 368 - 1176 2 x 25A 31.4A 16A 20.21 20.66 1690 x 2700 x 720 317 x 2 11.5 x 2 - €26,486(FDC400KXE6 + FDC400KXE6) FDC800KXE6* 80.0 90.0 2 to 58 400 - 1280 2 x 25A 35.8A 16A 22.54 23.46 1690 x 2700 x 720 317 x 2 11.5 x 2 - €27,486(FDC400KXE6 + FDC450KXE6) FDC850KXE6* 85.0 95.0 2 to 61 425 - 1360 1 x 25A 1 x 32A 37.8A 16A 24.24 24.83 1690 x 2700 x 720 317 x 2 11.5 x 2 - €30,573(FDC450KXE6 + FDC450KXE6) FDC900KXE6* 90.0 100.0 2 to 65 450 - 1440 2 x 32A 39.8A 16A 25.94 26.20 1690 x 2700 x 720 317 x 2 11.5 x 2 - €33,659(FDC450KXE6 + FDC504KXE6) FDC960KXE6* 96.0 108.0 2 to 69 480 - 1248 2 x 32A 43.0A 16A 27.70 28.22 2048 x 2700 x 720 341 + 317 11.5 x 2 - €35,080(FDC504KXE6 + FDC504KXE6) FDC1010KXE6 101.0 113.0 2 to 59 504 - 1313 2 x 32A 46.2A 16A 29.46 30.24 2048 x 2700 x 720 341 x 2 11.5 x 2 - €36,502(FDC504KXE6 + FDC560KXE6) FDC1065KXE6 106.5 119.5 2 to 62 532 - 1384 1 x 32A 1 x 40A 48.8A 16A 31.52 31.91 2048 x 2700 x 720 341 x 2 11.5 x 2 - €37,232(FDC560KXE6 + FDC560KXE6) FDC1130KXE6 113.0 127.0 2 to 66 565 - 1469 2 x 40A 51.4A 16A 33.58 33.58 2048 x 2700 x 720 341 x 2 11.5 x 2 - €37,962(FDC560KXE6-K + FDC615KXE6) FDC1180KXE6 118.0 132.0 3 to 69 590 - 1534 2 x 40A 55.4A 16A 37.16 35.27 2048 x 2700 x 720 360 + 341 11.5 x 2 - €41,678(FDC615KXE6 + FDC615KXE6) FDC1235KXE6 123.5 138.0 3 to 72 615 - 1605 2 x 40A 60.6A 16A 40.74 36.96 2048 x 2700 x 720 355 x 2 11.5 x 2 - €43,921(FDC615KXE6 + FDC680KXE6) FDC1300KXE6 130.0 142.0 3 to 76 650 - 1690 1 x 40A 1 x 50A 67.2A 16A 45.35 37.56 2048 x 2700 x 720 355 + 360 11.5 x 2 - €44,650(FDC680KXE6 + FDC680KXE6) FDC1360KXE6 136.0 146.0 3 to 80 680 - 1768 2 x 50A 73.8A 16A 49.96 38.16 2048 x 2700 x 720 355 x 2 11.5 x 2 - €45,379Weight (kg)Sound PressureLevel (dBA)Factory RefCharge (kg)HRP CODE<strong>List</strong> <strong>Price</strong>Operating Range (Outdoor Air), Cooling -15ºC DB to 43ºC, Heating -20ºC WB to 15.5ºC WB* When connecting the indoor unit types FDK, FDFL, FDFU or FDFW, the Connectable Capacity is limited to no higher than 130%.28 www.hrponline.co.uk 29


VRF heat recovery (3-pipe) outdoor units KXR6• Employs DC inverter compressors only• High efficiency heat recovery allows simultaneous heating and coolingKXR OUTDOOR UNITS 3-pipeModelNominal Capacity (kW)Cooling HeatingNo. Of UnitsConnectableConnectableCapacityPower Source RatingD-Curve MCB415V/50Hz/3ph (TPNE)Running Current(per phase)Start Current(per phase)Power Input (kW)Cooling HeatingDimensionsH x W x D (mm)FDC224KXRE6* 22.4 25.0 1 to 20 112 - 448 1 x 16A 9.2A 5A 5.90 5.90 1690 x 1350 x 720 252 57 8.7 621485 €10,325FDC280KXRE6* 28.0 31.5 1 to 25 140 - 560 1 x 20A 13.5A 5A 8.46 8.46 1690 x 1350 x 720 252 59 9.9 621490 €11,237FDC335KXRE6* 33.5 37.5 1 to 30 167 - 670 1 x 25A 15.9A 5A 9.98 9.55 1690 x 1350 x 720 256 62.5 11.4 621495 €13,514FDC400KXRE6* 40.0 45.0 1 to 36 200 - 800 1 x 25A 19.9A 8A 11.61 11.93 1690 x 1350 x 720 337 60 11.5 621505 €15,793FDC450KXRE6* 45.0 50.0 1 to 40 225 - 900 1 x 32A 22.0A 8A 13.49 13.32 1690 x 1350 x 720 337 62.5 11.5 621510 €18,981FDC504KXRE6* 50.4 56.5 1 to 36 252 - 806 1 x 32A 25.2A 8A 15.18 15.12 2048 x 1350 x 720 361 62 11.5 621515 €20,878FDC560KXRE6* 56.0 63.0 1 to 40 280 - 896 1 x 40A 28.4A 8A 17.95 16.79 2048 x 1350 x 720 361 63.5 11.5 621520 €21,609FDC615KXRE6* 61.5 69.0 2 to 44 308 - 984 1 x 50A 34.7A 8A 21.47 19.11 2048 x 1350 x 720 375 64.5 11.5 621525 €25,259FDC680KXRE6* 68.0 73.0 2 to 49 340 - 1088 1 x 63A 44.9A 8A 25.99 19.69 2048 x 1350 x 720 375 65.5 11.5 621530 €25,989(FDC335KXRE6-K + FDC400KXRE6) FDC735KXRE6* 73.5 82.5 2 to 53 368 - 1176 2 x 25A 35.4A 16A 21.08 21.30 1690 x 2700 x 720 337 x 2 62 33.0 - €30,388(FDC400KXRE6 + FDC400KXRE6) FDC800KXRE6* 80.0 90.0 2 to 58 400 - 1280 2 x 25A 39.8A 16A 23.22 23.86 1690 x 2700 x 720 337 x 2 63 33.0 - €31,585(FDC400KXRE6 + FDC450KXRE6) FDC850KXRE6* 85.0 95.0 2 to 61 425 - 1360 1 x 25A 1 x 32A 41.9A 16A 25.10 25.00 1690 x 2700 x 720 337 x 2 64.5 33.0 - €34,774(FDC450KXRE6 + FDC450KXRE6) FDC900KXRE6* 90.0 100.0 2 to 65 450 - 1440 2 x 32A 44.0A 16A 26.98 26.64 1690 x 2700 x 720 337 x 2 66 33.0 - €37,962(FDC450KXRE6 + FDC504KXRE6) FDC960KXRE6* 96.0 108.0 2 to 69 480 - 1536 2 x 32A 47.2A 16A 28.64 29.17 2048 x 2700 x 720 361 + 337 65 33.0 - €39,859(FDC504KXRE6 + FDC504KXRE6) FDC1010KXRE6 101.0 113.0 2 to 59 504 - 1311 2 x 32A 50.4A 16A 30.36 30.24 2048 x 2700 x 720 361 x 2 64.5 33.0 - €41,756(FDC504KXRE6 + FDC560KXRE6) FDC1065KXRE6 106.5 119.5 2 to 62 532 - 1384 1 x 32A 1 x 40A 53.2A 16A 33.13 31.91 2048 x 2700 x 720 361 x 2 65 33.0 - €42,486(FDC560KXRE6 + FDC560KXRE6) FDC1130KXRE6 113.0 127.0 2 to 66 560 - 1469 2 x 40A 56.8A 16A 35.90 33.58 2048 x 2700 x 720 361 x 2 65.5 33.0 - €43,217(FDC560KXE6-K + FDC615KXE6) FDC1180KXRE6 118.0 132.0 3 to 69 590 - 1534 1 x 40A 1 x 50A 63.1A 16A 39.42 35.90 2048 x 2700 x 720 375 + 361 66.5 33.0 - €47,237(FDC615KXRE6 + FDC615KXRE6) FDC1235KXRE6 123.5 138.0 3 to 72 615 - 1605 2 x 50A 69.4A 16A 42.94 38.22 2048 x 2700 x 720 375 x 2 67 33.0 - €50,517(FDC615KXRE6 + FDC680KXRE6) FDC1300KXRE6 130.0 142.0 3 to 76 650 - 1690 1 x 50A 1 x 63A 79.6A 16A 47.46 38.80 2048 x 2700 x 720 375 x 2 67.5 33.0 - €51,248(FDC680KXRE6 + FDC680KXRE6) FDC1360KXRE6 136.0 146.0 3 to 80 680 - 1768 2 x 63A 89.8A 16A 51.98 39.38 2048 x 2700 x 720 375 x 2 67.5 33.0 - €51,978Operating Range (Outdoor Air), Cooling -15ºC DB to 43ºC, Heating -20ºC WB to 15.5ºC WB* When connecting the indoor unit types FDK, FDFL, FDFU or FDFW, the Connectable Capacity is limited to no higher than 130%.Weight (kg)Sound PressureLevel (dBA)Factory RefCharge (kg)HRP CODE<strong>List</strong> <strong>Price</strong>KX Branch pipesKX/KXR Branch pipes & Branch ControllersMINI KX6 (2-PIPE HEAT PUMP) BRANCH PIPES & HEADERSType Model Description HRP CODE <strong>List</strong> <strong>Price</strong>Branch Pipe Kit DIS-22-1 Downsteam capacity less than 180 621001 €107Branch Pipe Kit DIS-180-1 Downsteam capacity of 180 to 370 621011 €107Header (4 Branch) HEAD4-22-1 Downsteam capacity less than 180 621286 €238Header (6 Branch) HEAD6-180-1 Downsteam capacity of 180 to 370 621291 €276KX6 (2-PIPE HEAT PUMP) BRANCH PIPES & HEADERSType Model Description HRP CODE <strong>List</strong> <strong>Price</strong>Branch Pipe Kit DIS-22-1 Downsteam capacity less than 180 621001 €107Branch Pipe Kit DIS-180-1 Downsteam capacity of 180 to 370 621011 €107Branch Pipe Kit DIS-371-1 Downsteam capacity of 371 to 539 621021 €142Branch Pipe Kit DIS-540-1 Downsteam capacity of 540 or more 623426 €284Header (4 Branch) HEAD4-22-1 Downsteam capacity less than 180 621286 €238Header (6 Branch) HEAD6-180-1 Downsteam capacity of 180 to 370 621291 €276Header (8 Branch) HEAD8-371-1 Downsteam capacity of 371 to 539 621295 €373Header (8 Branch) HEAD8-540-2 Downsteam capacity of 540 or more 621298 €404Outdoor Unit Manifold DOS-2A-1 For combined outdoor units 623416 €206KXR6 (3-PIPE HEAT RECOVERY) PFD CONTROLLERS, BRANCH PIPES & HEADERSType Model Description HRP CODE <strong>List</strong> <strong>Price</strong>Branch Controller PFD1123-E Downsteam capacity less than 112 (connectable no. of units 1-5) 623108 €562Branch Controller PFD1803-E Downsteam capacity of 112 to 179 (connectable no. of units 1-8) 623113 €1,083Branch Controller PFD2803-E Downsteam capacity of 180 to 279 (connectable no. of units 1-10) 623117 €1,224Branch Controller (4-Way) PFD1123X4-EDownsteam capacity less than 112 per branch (1-5 units) with atotal capacity less than 371 (max. 16 units)623122 €2,302Extension Cable PFD-15WR-E 15m extension cable for PFD controller 621089 POABranch Pipe Kit DIS-22-1-R For units before PFD Controller - downsteam capacity less than 180 621006 €142Branch Pipe Kit DIS-180-1-R For units before PFD Controller - downsteam capacity of 180 to 370 621016 €142Branch Pipe Kit DIS-371-2-R For units before PFD Controller - downsteam capacity of 371 to 539 621025 €185Branch Pipe Kit DIS-540-2-R For units before PFD Controller - downsteam capacity of 540 or more 623430 €327Branch Pipe Kit DIS-22-1 For units after PFD Controller - downsteam capacity less than 180 621001 €107Branch Pipe Kit DIS-180-1 For units after PFD Controller - downsteam capacity of 180 to 370 621011 €107Branch Pipe Kit DIS-371-1 For units after PFD Controller - downsteam capacity of 371 to 539 621021 €142Branch Pipe Kit DIS-540-2 For units after PFD Controller - downsteam capacity of 540 or more 621297 €284Outdoor Unit Manifold DOS-2A-1-R For combined outdoor units 623421 €230These can be used with KXR4 & KXR6 Outdoor Units but with only KXE6 Indoor Units30www.3dair .co.uk31


VRF Indoor unitsFDT FDTC FDTQ FDUT FDUH FDUMFDU FDE FDK FDFW FDFUTypeModelNominal Capacity (kW)Cooling HeatingPower Supply230V/50Hz/1phDimensionsH x W x D (mm)Weight(kg)Air Volume(m3/s)Sound PressureLevel (dBA)FDT: 4-Way Cassette FDT28KXE6D 2.8 3.2 5A 246 x 840 x 840 22 0.23 - 0.27 - 0.30 30 / 31 / 33 621623 €1,222FDT36KXE6D 3.6 4.0 5A 246 x 840 x 840 22 0.23 - 0.27 - 0.30 30 / 31 / 33 621633 €1,261FDT45KXE6D 4.5 5.0 5A 246 x 840 x 840 22 0.23 - 0.27 - 0.30 30 / 31 / 33 621643 €1,410FDT56KXE6D 5.6 6.3 5A 246 x 840 x 840 24 0.23 - 0.27 - 0.30 30 / 31 / 33 621653 €1,452FDT71KXE6D 7.1 8.0 5A 246 x 840 x 840 24 0.23 - 0.27 - 0.30 30 / 31 / 33 621658 €1,530FDT90KXE6D 9.0 10.0 5A 298 x 840 x 840 27 0.33 - 0.40 - 0.45 35 / 37 / 40 621663 €1,703FDT112KXE6D 11.2 12.5 5A 298 x 840 x 840 27 0.33 - 0.40 - 0.45 35 / 37 / 40 621668 €1,939FDT140KXE6D 14.0 16.0 5A 298 x 840 x 840 27 0.38 - 0.45 - 0.50 37 / 40 / 42 621673 €2,197FDT160KXE6D 16.0 18.0 5A 298 x 840 x 840 27 0.38 - 0.45 - 0.50 38 / 41 / 43 621678 €2,266Fascia Panel T-PSA-3AW-E - - - 35 x 950 x 950 5.5 - - 623209 €204FDTC: Cassette (600x600) FDTC22KXE6D 2.2 2.5 5A 248 x 570 x 570 14 0.13 - 0.14 - 0.16 32 / 33 / 35 621613 €1,152FDTC28KXE6D 2.8 3.2 5A 248 x 570 x 570 14 0.13 - 0.14 - 0.16 32 / 33 / 35 621628 €1,164FDTC36KXE6D 3.6 4.0 5A 248 x 570 x 570 15 0.13 - 0.15 - 0.17 34 / 36 / 38 621618 €1,222FDTC45KXE6D 4.5 5.0 5A 248 x 570 x 570 15 0.15 - 0.17 - 0.18 34 / 37 / 40 621638 €1,290FDTC56KXE6D 5.6 6.3 5A 248 x 570 x 570 15 0.17 - 0.19 - 0.22 34 / 39 / 45 621648 €1,382Fascia Panel TC-PSA-25W-E - - - 35 x 700 x 700 3.5 - - 627043 €196FDTQ: 1-Way Cassette FDTQ22KXE6D 2.2 2.5 5A 250 x 570 x 570 23 0.09 - 0.12 33 / 38 621728 €1,274(600x600) FDTQ28KXE6D 2.8 3.2 5A 250 x 570 x 570 23 0.09 - 0.12 33 / 38 621733 €1,303FDTQ36KXE6D 3.6 4.0 5A 250 x 570 x 570 23 0.09 - 0.12 33 / 38 621738 €1,334Fascia Panel TQ-PSA-15W-E - - - 35 x 625 x 650 2.5 - - 623687 €196FDUT: Ultra Slim Ducted FDUT22KXE6D 2.2 2.5 5A 220 x 750 x 520 26 0.08 - 0.10 - 0.13 24 / 26 / 29 621965 €1,026FDUT Filter Kits - see below FDUT28KXE6D 2.8 3.2 5A 220 x 750 x 520 26 0.08 - 0.10 - 0.13 24 / 26 / 29 621970 €1,074FDUT36KXE6D 3.6 4.0 5A 220 x 750 x 520 26 0.10 - 0.12 - 0.14 28 / 31 / 33 621975 €1,102FDUT45KXE6D 4.5 5.0 5A 220 x 950 x 520 28 0.13 - 0.17 - 0.20 28 / 32 / 35 621980 €1,149FDUT56KXE6D 5.6 6.0 5A 220 x 950 x 520 28 0.14 - 0.17 - 0.21 31 / 34 / 36 621985 €1,179Filter Kit FDUT FDUT 22 - 36 type UT-FL1E 624326 €121Filter Kit FDUT FDUT 45 - 56 type UT-FL2E 624328 €121FDUH: Compact Ducted FDUH22KXE6D 2.2 2.5 5A 257 x 570 x 530 22 0.10 - 0.11 - 0.12 27 / 30 / 33 623512 €1,071(control box & drain piping FDUH28KXE6D 2.8 3.2 5A 257 x 570 x 530 22 0.10 - 0.11 - 0.12 27 / 30 / 33 623517 €1,090can be left or right handed) FDUH36KXE6D 3.6 4.0 5A 257 x 570 x 530 22 0.10 - 0.11 - 0.12 27 / 30 / 33 623522 €1,201Filter Kit FDUH FDUH all models type UH-FL1E 624310 €121FDUM: Ducted FDUM22KXE6D 2.2 2.5 5A 299 x 750 x 635 33 0.13 - 0.15 - 0.17 28 / 31 / 33 621783 €1,097FDUM28KXE6D 2.8 3.2 5A 299 x 750 x 635 34 0.17 - 0.18 - 0.20 28 / 31 / 34 621788 €1,134FDUM36KXE6D 3.6 4.0 5A 299 x 750 x 635 34 0.17 - 0.18 - 0.20 28 / 31 / 34 621793 €1,305FDUM45KXE6D 4.5 5.0 5A 299 x 750 x 635 34 0.18 - 0.20 - 0.23 29 / 32 / 35 621798 €1,361FDUM56KXE6D 5.6 6.3 5A 299 x 750 x 635 34 0.18 - 0.20 - 0.23 29 / 32 / 35 621803 €1,415FDUM71KXE6D 7.1 8.0 5A 299 x 950 x 635 40 0.23 - 0.27 - 0.30 29 / 32 / 35 621808 €1,502FDUM90KXE6D 9.0 10.0 5A 299 x 950 x 635 40 0.25 - 0.30 - 0.33 30 / 33 / 36 621813 €1,723FDUM112KXE6D 11.2 12.5 5A 350 x 1370 x 635 59 0.37 - 0.42 - 0.47 32 / 35 / 37 621818 €2,117FDUM140KXE6D 14.0 16.0 5A 350 x 1370 x 635 59 0.45 - 0.52 - 0.57 33 / 36 / 38 621823 €2,258Filter Kit FDUM FDUM 22 - 56HKXE6 type UM-FL1E 624312 €121Filter Kit FDUM FDUM 71 - 90 HKXE6 type UM-FL2E 624314 €121Filter Kit FDUM FDUM 122 - 140 HKXE6 type UM-FL3E 624316 €121HRPCODE<strong>List</strong><strong>Price</strong>TypeModelNominal Capacity (kW)Cooling HeatingFDU: High-Static Ducted FDU71KXE6D 7.1 8.0 5A 297 x 850 x 650 40 0.33 - 0.42 37 / 41 621928 €1,606FDU90KXE6D 9.0 10.0 5A 350 x 1370 x 650 63 0.45 - 0.57 37 / 42 621933 €1,826FDU112KXE6D 11.2 12.5 5A 350 x 1370 x 650 63 0.45 - 0.57 38 / 42 621938 €2,240FDU140KXE6D 14.0 16.0 5A 350 x 1370 x 650 63 0.56 - 0.70 39 / 43 621943 €2,362FDU224KXE6D 22.4 25.0 5A 360 x 1570 x 830 92 0.85 51 621773 €3,648FDU280KXE6D 28.0 31.5 5A 360 x 1570 x 830 92 1.13 52 621778 €3,674FDE: Ceiling Suspended FDE36KXE6D 3.6 4.0 5A 210 x 1070 x 690 28 0.12 - 0.15 - 0.18 36 / 38 / 39 621543 €1,700FDE45KXE6D 4.5 5.0 5A 210 x 1070 x 690 28 0.12 - 0.15 - 0.18 36 / 38 / 39 621548 €1,761FDE56KXE6D 5.6 6.3 5A 210 x 1070 x 690 28 0.12 - 0.15 - 0.18 36 / 38 / 39 621553 €1,805FDE71KXE6D 7.1 8.0 5A 210 x 1320 x 690 37 0.20 - 0.23 - 0.30 37 / 39 / 41 621558 €1,927FDE112KXE6D 11.2 12.5 5A 250 x 1620 x 690 49 0.35 - 0.38 - 0.43 39 / 41 / 44 621563 €2,001FDE140KXE6D 14.0 16.0 5A 250 x 1620 x 690 49 0.38 - 0.43 - 0.48 43 / 44 / 46 621568 €2,332FDK: High Wall FDK22KXE6D 2.2 2.5 5A 298 x 840 x 259 12 0.10 - 0.12 - 0.13 31 / 33 / 35 621578 €848FDK28KXE6D 2.8 3.2 5A 298 x 840 x 259 12 0.10 - 0.12 - 0.13 31 / 33 / 35 621583 €869FDK36KXE6D 3.6 4.0 5A 298 x 840 x 259 12 0.12 - 0.15 - 0.17 31 / 35 / 39 621588 €891FDK45KXE6D 4.5 5.0 5A 298 x 840 x 259 12.5 0.12 - 0.15 - 0.18 33 / 37 / 42 621593 €924FDK56KXE6D 5.6 6.3 5A 298 x 840 x 259 13 0.17 - 0.20 - 0.23 37 / 42 / 46 621598 €1,031FDK71KXE6D 7.1 8.0 5A 318 x 1098 x 248 15.5 0.25 - 0.30 - 0.35 39 / 43 / 47 621603 €1,076FDFW/FDFL: Floor Mounted FDFW28KXE6D 2.8 3.2 5A 600 x 860 x 238 19 0.12 - 0.13 - 0.15 30 / 34 / 36 623574 €1,215(With Casing) FDFW45KXE6D 4.5 5.0 5A 600 x 860 x 238 20 0.12 - 0.13 - 0.15 33 / 36 / 38 623582 €1,242FDFW56KXE6D 5.6 6.3 5A 600 x 860 x 238 20 0.13 - 0.15 - 0.18 33 / 37 / 44 623588 €1,274FDFL71KXE6D 7.1 8.0 5A 630 x 1481 x 225 40 0.20 - 0.25 - 0.30 40 / 41 / 43 621882 €1,888FDFU: Floor Mounted FDFU28KXE6D 2.8 3.2 5A 630 x 1077 x 225 25 0.17 - 0.18 - 0.20 36 / 38 / 41 621887 €1,680Concealed Type FDFU45KXE6D 4.5 5.0 5A 630 x 1077 x 225 25 0.17 - 0.20 - 0.23 40 / 41 / 43 621892 €1,696(Without Casing) FDFU56KXE6D 5.6 6.3 5A 630 x 1077 x 225 25 0.17 - 0.20 - 0.23 40 / 41 / 43 621897 €1,726FDFU71KXE6D 7.1 8.0 5A 630 x 1362 x 225 32 0.20 - 0.25 - 0.30 40 / 41 / 43 621902 €1,772SAF Heat Exchange Ventilation Units & DX KitsPower Supply230V/50Hz/1phDimensionsWeightH x W x D (mm)(kg)Air Volume(m3/s)Sound PressureLevel (dBA)SAF: Fresh Air Ventilation SAF250E4 - - 5A 270 x 882 x 599 29 0.05 - 0.07 22 / 28 629887 €1,595And Heat Exchange Unit SAF350E4 - - 5A 270 x 882 x 804 37 0.08 - 0.10 26 / 32 629885 €1,832SAF500E4 - - 5A 270 x 962 x 904 43 0.10 - 0.14 26 / 34 629883 €2,075SAF800E4 - - 5A 388 x 1322 x 884 71 0.18 - 0.22 34 / 39 629879 €3,192SAF1000E4 - - 5A 388 x 1322 x 1135 83 0.23 - 0.28 33 / 38.5 629887 €3,529SAF-DX250KXE6 DX kit for SAF250 629303 €3,759SAF-DX350KXE6 DX kit for SAF350 629308 €4,056SAF-DX500KXE6 DX kit for SAF500 629313 €4,350SAF-DX800KXE6 DX kit for SAF800 629318 €4,677SAF-DX1000KXE6 DX kit for SAF1000 629323 €4,974HRPCODE<strong>List</strong><strong>Price</strong>32www.hrponline.co.uk33


Valve KitsControls and accessoriesEEV-KIT is a control kit for operating a locally providedAHU and/or fan coil units with direct expansion (DX)heat exchanger interlaced coils combined with the KX6VRF Range.SINGLE REFRIGERATION SYSTEMFANAHUEEV-Control AssemblyEEV-Control BoxSensor (5pcs)Thi-A Thi-R2 Thi-AFThi-R1 Thi-R3There are 3 types of EEV Valve AssembliesEEV - KIT+StrainerMULTI REFRIGERATION SYSTEMFANAHUEEV-Valve AssemblyEEV valve, body EEV coilStrainerAVAILABLE SUMMER <strong>2011</strong>EEV-Kit (air handling unit interface)The diagram represents a 4-circuitinterlaced heat exchangerThe EEV-Kit is made up of the EEVControl Assembly and the EEV-ValveAssembly (coil and strainers).Please note the the Control Assemblyis not waterproof and must be housedin a weatherproof enclosure.RCH-E3 (wired)RC-E4 (wired)SC-SL2N-ESC-SL3N-AE/BESModel Description HRP CODECONTROLSRC-E4 Wired remote controller (2 wire) - new PAC & KX6 623194 €86RCH-E3 Simplified wired remote controller (2 wire) - new PAC & KX6 623988 €134SC-ADNA-E Super Link adapter 623384 €134PJA504A178XR 6-Way Adaptor to CnT port for run, fault, on/off, heat, & compressor run 633086 €21SC-THB-E3 Remote Sensor 623994 €111SC-BIKN-E Interface for use of wired remote controller (RC-E4) - SRK & SRF-ZJX-S indoor units 623384 €204RCN-E-E Infra-red remote control kit FDE (ceiling suspended) 623477 €173RCN-K-E Wireless RC for FDK 623482 €173RCN-K71-E Wireless RC for FDK71 623487 €173RCN-FW-E Wireless RC for FDFW 623492 €173RCN-T36W-E Infra-red remote control kit for FDT (cassette) 623203 €181RCN-TC-24W-E Infra-red remote control kit for FDTC-VB (compact cassette) 623338 €182RCND-KIT3-E Infra-red remote control kit for FDUM & FDU (ducted) 623452 €218CENTRAL CONTROLS AND BMS GATEWAYSSC-SL1N-E Centralised controller (on/off of up to 16 indoor units) 623400 €570SC-SL2NA-E Centralised controller (on/off & weekly timer function of up to 64 indoor units) 623435 €1,074SC-SL3NA-AE Touch panel centralised controller (multi-function of up to 128 indoor units) 623442 €5,162SC-SL3NA-BE Touch panel centralised controller (multi-function of up to 128 indoor units+electricity usage calculation) 623447 €5,531SC-WGWNA-A Web gateway (for PC Windows central control via Internet Explorer) 629206 €5,745SC-LGWNA-A LONworks gateway 629042 €7,182SC-BGWNA-A BACnet gateway 629035 €7,182SLB-3BX Backbox for SC-SL3N touch panel centralised controller 623472 €95FD-MULTI SYSTEMS BRANCH PIPESDIS-WA1 Twin branch pipe kit FDC71 - 140 623001 €153DIS-WB1 Twin branch pipe kit FDC200 - 250 623006 €153DIS-TA1 Triple branch pipe kit - FDC140 623011 €153DIS-TB1 Triple branch pipe kit - FDC200 623013 €153FILTER KITS FOR DUCTED UNITSUH-FL1E Filter for FDUH 624310 €121UT-FL1E Filter for FDUT22 - 36 623368 €121UT-FL2E Filter for FDUT45 - 56 623370 €121U-FCR FAN Control kit for FDU 623387 €219U-FCRA FAN Control kit for FDU 623388 €219<strong>List</strong><strong>Price</strong>Type EEV6-71-E EEV6-160-E EEV6-280-ECapacity 22 - 71 90 - 160 224 - 280kW 2.2 - 7.1kW 9.0 - 16.0kW 22.4 - 28.0kWPart Number Description HRP CODE <strong>List</strong> <strong>Price</strong>EEVKIT6-E-M Master Control Assembly 629348 €2,209EEVKIT6-E-C Slave Control Assembly 629345 €2,209EEV6-71-E Valve Assembly 2.2-7.1kW (per DX coil) 629351 €184EEV6-160-E Valve Assembly 9.0-16kW (per DX coil) 629354 €257EEV6-280-E Valve Assembly 22.4-28kW (per DX coil) 629357 €297Air Handling Unit Valve Kit for FD Inverter Split SystemsValve Kits allow air handling units to be connected to high performance FD-Series split system outdoor units - from 7kW to 25kW. The installer is responsible for thedesign of the air handler and coil(s). The Valve Kit is suitable for control using Wired Controller RC-E4 (623194) - ordered separatelyAHU2PAC25 Valve Kit for FD-Series PAC 629335 €1,183Please contact 3D or HRP for further information.34www.3dair .co.uk35


xxxxxxxxxxxxxxxxxxxxAir to water Heat PumpSpecificationsAir to water heat pump is a revolutionary energyrecycling system which reduces environmental loadby reusing heat energy produced in daily life.This first-rate energy saving system has beendeveloped by our exceptional technology.Our Air to Water Heat Pump is a complete modernsystem for heating, cooling and producing hotsanitary water for houses, offering effective energysaving and reducing carbon dioxide emission. Ourproduct is safe and economical with integrated hotwater heater, immersion heater, circulating pumpand climate system within the indoor unit.The heat energy is retrieved from the outdoor air,and is transferred to the indoor unit by the mediumof refrigerant circulated in closed piping system.This eliminates the needs of bore holes and coilsassociated with ground source heat pumps.FeaturesFDCW71VNX FDCW100VNX HMA100VFDCW140VNX HMS140V MT300HMA100VMRadiator orFan coil• Optimum annual operation costs thanks to the inverter drivencompressor. The speed of the compressor is controlled according to thedemand, and the industries highest COP level of 4.08~4.44* in heatingoperation has been achieved.•The compact size (600x650mm footprint) has been achieved byintegrating the hot water tank for sanitary water together with thewater heat exchanger in indoor unit. Electric wiring and piping worksare simpler due to integrated indoor unit design.•Max temperature flow line is 65ºC with use of a large-capacity auxiliaryelectric heater as standard equipment for back-up so that the systemwill be able to cope with irregular and excessive use of hot water.(58ºC with only use of compressor)36FloorHeatingRefrigerantWater pipe (for Air Conditioning)Water pipe (for Sanitary)Water heat exchanger+ Heat storage unitSanitaryAir - water heat circulationsystem is an excellent energyrecycling system.• Various sterilization temperature settings according to the requirementsof each country.•Water supply pressure at showers and faucets to second and thirdfloors will not drop. By utilizing the direct incoming water supply andnot using water from a storage tank water pressure and quality ismaintained as well as the reduction in risk of legionella bacteriageneration.It is recommended that installers/engineers attend the MHI Air to Water Training Course Module 20Selling Category - WSystem Heating Output Indoor Model HRP Code <strong>List</strong> <strong>Price</strong> * Outdoor Model HRP Code <strong>List</strong> <strong>Price</strong> * Tank Size (L) SYSTEM LIST PRICE *7.1kW (3.0 - 8.0kW) 3.0HP HMA100V 620020 p.o.a. FDCW71VNX 620500 p.o.a. 270 p.o.a.9.0kW (3.5 - 12.0kW) 3.5HP HMA100V 620020 p.o.a. FDCW100VNX 620510 p.o.a. 270 p.o.a.14.0kW (3.0 - 16.5kW) 6.0HP HMS140HT30 620105 p.o.a. FDCW140VNX 620520 p.o.a. 30 p.o.a.14.0kW (3.0 - 16.5kW) 6.0HP HMS140MT300 6<strong>2011</strong>0 p.o.a. FDCW140VNX 620520 p.o.a. 300 p.o.a.14.0kW (3.0 - 16.5kW) 6.0HP HMS140MT500 6<strong>2011</strong>5 p.o.a. FDCW140VNX 620520 p.o.a. 500 p.o.a.* The above list prices are subject to the 3D/HRP air to water discount structure. The heating outputs are at 7ºC DB (6ºC WB) with a water temperature of 45ºC out / 40ºC in.3HP 3.5HP 6HPIndoor Model HMA100V HMA100VM HMA100V HMA100VM HMS140VOutdoor Model FDCW71VNX FDCW100VNX FDCW140VNXPower source 1 phase 230V 50Hz 1 phase 230V 50Hz 1 phase 230V 50Hz3 phase 400V 50Hz 3 phase 400V 50Hz 3 phase 400V 50HzHeating condition 1 kW 8.0 (3.0-8.0) 9.0 (3.5-12.0) 16.5 (5.8-16.5)Nominal capacity condition 2 kW 8.3 (2.0-8.3) 9.2 (3.5-10.5) 16.5 (4.2-17.2)COP condition 1 3.33 3.60 3.31condition 2 4.08 4.44 4.20Cooling condition 1 kW 7.1 (2.0-7.1) 8.0 (3.0-9.0) -Nominal capacity condition 2 kW 10.7 (2.7-10.7) 11.0 (3.3-12.0) 16.5 (5.2-16.5)EER condition 1 2.68 2.81 -condition 2 3.35 3.62 3.59Tapping capacity 12liter/min litre 270 270 -16liter/min litre 200 200 -Operation range heating -20-43*(Ambient temperature) Cooling 15-43Operation range heating 25-58 (65 with immersion heater)(Water temperature) cooling 7-25 18-25Max refrigerant pipe length m 30 12 30Max height difference between IU and OU m 7Indoor UnitHeight mm 1760 (+20-50mm, adjustable feet) 1004Width mm 600 513Depth mm 650 360Weight (without water in the system) Kg 140 60Immersion heater 9kW 4steps (1/phase or 3/phase) -Volume total litre 270 +5% -Volume hot water coil litre 14 -Volume expansion vessel litre - 18Dimensions, climate system pipe mm 22 28Dimensions, hot water pipe mm 22--Water pipe connectionsCompression fittingsOutdoor UnitHeight mm 595 845 1300Width mm 780 (+67 with value cover) 970 970Depth mm 340 370 (+80 with foot rail) 370 (+80 with foot rail)Weight Kg 60 74 105Sound Power level*2 dB(A) 64 64.5 71Sound Pressure level*2 dB(A) 48 50 54Airflow m3/min 50 73 100Type of compressorRotaryRef controlEEVRefrigerant volume(pipe length without additional charge) Kg 2.55 (15) 2.19 (12) 4.0 (15)Dimensions, refrigerant pipe mm(inches) Gas pipe: OD 15.88 (5/8’’), Liquid pipe: OD 9.52 (3/8’’)Ref pipe connectionsFlareMHI Water Tanks (for HMS140V hydro indoor unit only) are available in 30 litre, 300 litre and 500 litre capacities.Please contact 3D/HRP for further technical information.If a third party water storage tank is used there will be a reduction of water pressure at showers and faucets whenthey are used at the same time.www.hrponline.co.uk37


Error CodesError CodesRemote ControlError CodeLocation of Issue- Indoor Unit Power- Remote Controller WiresDescription of IssuePower Off; Broken wire loom, fuseBroken transformer wirePoor connection, break in controller wire*For wire breaking at power ON, the LED is off- Remote Controller *Defective Remote Controller PCBWait or Stays Off Indoor-Outdoor units connection wire *Poor connection, break of indoor-outdoor unit connection wireWait or Stays Off Remote Control Improper setting of master and slave by r/cPoor connection of R/C signal wire (white)E1 R/C Wires (Noise) *For wire break at power on the LED is off Intrusion of noise in r/c wire*Defective R/C or indoor control unit PCB (defective communication circuit)E3 Outdoor signal line Indoor unit power failure control wiring open circuit or incorrectly wiredE5E6E7E8E9Indoor-outdoor units connection wireCommunication cable (noise)Indoor hx thermistorIndoor Unit return air sensorInstall or Operating conditionIndoor HX thermistorDrain TroubleFloat SwitchPoor connection of wire between in/outdoor during operation(disconnect/loose connection)CPU-runaway on outdoor unit control PCBDefective indoor units HX temperature sensor (broken thermistor, short circuit)Poor contact of temperature thermistor connectorDefective indoor unit return air sensor (broken/short circuit) orPoor contact of temperature sensor connectorHeating Overload (High Indoor HX temperature)Defective indoor unit HX thermistor (short circuit)Defective drain pump (DM), broken drain pump wire, disconnected connectorAbnormal float switch operation (malfunction)E10 Excessive No. of Connected Indoors (more than 16) When Multi-Unit control by R/C is performed, the number of IU is over 16E12 Address setting error Improper addressing of indoor unitE14E16Master/slave Indoor unit address No. SettingCommunication error between master and slave indoor unitsFan MotorBlown Fan Motor FuseImproper master and slave address settingAbnormal r/c wire connection, broken between master and slave unitsDefective fan motor (FDT)Defective indoor unit control PCBE19 Indoor unit control PCB Improper operation mode setting of drain motorE28R/C temperature thermistorR/C temperature thermistor connectorBroken wire of R/C temperature ThermistorFaulty connection of R/C temperature ThermistorE30Unmatched connection of indoor/outdoor unitFaulty signal wiring or open circuitIndoor / outdoor unit PCB faultImproper addressing of outdoor unitE31 Duplicated outdoor unit address No. More than 128 indoor unitsNo setting or master/slave on combination outdoorE32 Open L3 Phase on power supply Faulty power supply and L3 primary sideE33 Power Supply Wires Abnormal current on inverter primary sideE35Installation, Op. StatusHigher Outdoor unit HX temperatureOU HX temperature ThermistorDefective OU HX temperature ThermistorRemote ControlError CodeLocation of IssueDescription of IssueE35 OU Control PCB Defective OU control PCB (defective temp sensor input circuit)E36E37E38E39E40E41E43E42E45E46E47E48E49Discharge pipe temperature errorOutdoor heat exchanger temperature anomalyAmbient air temperature thermistor anomalyDischarge pipe temperature thermistor anomalyHigh pressure error (63H1 activated)Power transistor overheatExcessive number of indoor units or capacity of connectionCurrent CutInverter communication errorMixed address settings on same networkInverter over-current errorDC outdoor fan motor errorLow pressure errorLow pressure sensor anomalyDefective discharge pipe temperature thermistorClogged filter / short circuit of outdoor unitsBroken outdoor heat exchanger thermistorDisconnected / defective thermistor connectorBroken air temperature thermistorDisconnected / defective thermistor connectorBroken discharge pipe thermistorDisconnected / defective thermistor connectorShort cicuit of air flow / breakdown of fan motorDefective 63H1 connector, Closed service valveDefective outdoor unit fan motor Improperly fixed power transistor radiator finDefective power transistor temperature thermistorToo many indoor units connected, exceeds capacityImproper indoor/outdoor unit address settingFaulty power supply, power transistor, compressorService valves closed, insufficient refrigerantDefective connector between PCB and inverter PCBDefective Inverter PCBOld superlink (KX4)/ New superlink (KX6) mixedon the same networkDust on Control PCB, defective outdoor control PCBBlown F3 fuseDust on Control PCB, defective outdoor control PCBDefective fan motor, Blown F3 fuseDetective suction pipe temperature thermistor/connectorDefective low pressure sensor or sensor connectionE51 Inverter fan motor anomaly Defective fan motor or Inverter control PCBE53E54E55Suction pipe temperature thermistor anomalyLow pressure sensor anomalyUnderneath temperature thermistor anomalyDefective suction pipe temperature thermistorDefective suction pipe temperature thermistor connectorDefective low pressure sensor or connectionImproper amount of refrigerantDefective underneath temperature thermistor Defective underneathtemperature thermistor connectorE56 Power transister temperature sensor anomaly Insufficient time passed after crankcase heater on faulty compressorE57Insufficient refrigerant amountService valve closureInsufficient refrigerant amount / closed valvesDefective indoor R/A temperature thermistor or connectorE58 Anomalous Compressor by loss of synchronism Compressor started without crack case heater onFaulty fan motor, improper refrigerant amountE59 Compressor startup failure Abnormal power supply or faulty compressorDefective outdoor fan motor or inverter PCBE60Compressor rotor lockImproper refrigerant amountAbnormal power supply or faulty compressorE63 Emergency stop On signal submitted on CnT terminal of indoor unit38www.3dair .co.uk39


MHI TrainingTechnical CentreAIR CONDITIONING & HEAT PUMP TECHNOLOGYSponsored by MITSUBISHI HEAVY INDUSTRIESTraining for EngineersTechnical training has provided a huge benefit forinstallers, service engineers and controls techniciansover the last few years. MHI split systems and VRFsystems are constantly being developed, withimproved specifications and performance, so acomprehensive understanding of installationprocedures, commissioning, and troubleshooting,allows engineers to be fully competent and costeffective when applying their skills.MHI TrainingModule 1 – Introduction to MHI EquipmentModule 2 – RAC (Splits) & PAC (Multi-Splits)Module 3 – KX VRF Application & SelectionModule 4 – KX VRF Operation, Installation & ServiceModule 7 – SLA & SLB Control Systems & OperationModule 8 – Installing MHI R410A onto existing linesModule 9 – Mente PC KX & KXR System MonitoringModule 10 – Commissioning KX & KXRNEWModule 11 – Installation & Troubleshooting –Split SystemsModule 12 – Intensive Troubleshooting & Diagnostics(3 hour)C&G2079 F-Gas Courses – IncludingAssessmentThe deadline for engineers is 4th July <strong>2011</strong>. After thisdate it will be illegal to work on systems containingrefrigerant. The courses, including Assessment andCertification, are undertaken at many of the HRPService Centres, providing both a consistent andlocalised availablility. All course bookings, allocationof spaces, cancellations, etc, are subject to HRP <strong>Ltd</strong>Terms and Conditions.C&G2079 Course Content• Analysing system performance to determineefficiency by utilising pressure, temperature stateof Refrigerant, etc.•How to carry out an adequate leak test, using bothdirect and indirect methods• Understanding theoretical operation of arefrigeration/air conditioning system• Brazing and Jointing skills• Identifying Refrigerants••Charging and recovering a zeotropic refrigerantHow to pressure test and evacuate in compliancewith BS-EN378-2008• Completing the required records to comply withF-Gas Regulations•Disposing of all created hazardous waste in thecorrect legal mannerThe MHI Technical Centre at Slough has workingsystems, including VRF with fully integrated controls,BMS Gateways, and Centralized Controllers.New MHI Training ModulesWe have recently introduced intensive practicaltraining for engineers who are already familiar withMHI and other equipment, and who are interested inextending their knowledge and getting updated onthe latest developments and control/diagnostictechnology. Two new courses – Modules 11 & 12are now running, and are proving extremely popular.These hands-on sessions are based specially designedrigs, and are held at HRP Service Centres throughoutthe country.3-day and 5-day Courses3-day Courses are available for the candidate whoalready has good knowledge of refrigerationprocesses, including the associated theory, with 5-daycourses for those who may have been out of trainingfor some time, and require more in-depth support ontheoretical knowledge.If you are unsure which course is right for you, pleasecomplete our online Skill Scan, and one of our trainerswill review the best option available.Please note: the Courses include a practical exam, and GOLAexam on C&G2079For full details please call: 01753 495702or visit: www.hrponline.co.ukTraining rig photos - Walthamstow service centre40www.hrponline.co.uk41


Installation Accessories from HRPxxxxxxxxxxxxxxxxxxxxInstallation Accessories, Materials and Tools available from HRP <strong>Ltd</strong> UK. Tel: 0044 (0)1925 837 688.Copper Tube – CoilsRefrigeration quality soft copperAll sizes suitable for R410ATube OD 15 metres 30 metresIsoline Insulation Class "0"Closed Cell – 15 metre lengths (internally talced)Sell Category C1/4" 143044 p.o.a. 143046 p.o.a.3/8" 143052 p.o.a. 143054 p.o.a.1/2" 143058 p.o.a. 143060 p.o.a.5/8" 143064 p.o.a. 143066 p.o.a.3/4" 143070 p.o.a. 143072 p.o.a.7/8" 143076 p.o.a. n/a p.o.a.For today's copper prices look on the HRP website – contact your Service Centre foraccess passwordIsoline Insulation Class "0"Sell Category MClosed Cell – 2 metre lengthsTube 1/4" <strong>List</strong> 3/8" <strong>List</strong> 1/2" <strong>List</strong>OD wall price wall price wall price1/4" 188168 p.o.a. 188247 p.o.a. 188360 p.o.a.3/8" 188182 p.o.a. 188255 p.o.a. 188379 p.o.a.1/2" 188190 p.o.a. 188263 p.o.a. 188387 p.o.a.5/8" 188204 p.o.a. 188271 p.o.a. 188395 p.o.a.3/4" 188212 p.o.a. 188298 p.o.a. 188409 p.o.a.7/8" 188220 p.o.a. 188301 p.o.a. 188417 p.o.a.Other sizes available on requestSell Category MTube OD 3/8" wall <strong>List</strong> price 1/2" wall <strong>List</strong> price1/4" 188353 p.o.a. 188507 p.o.a.3/8" 188354 p.o.a. 188508 p.o.a.1/2" 188355 p.o.a. 188509 p.o.a.5/8" 188356 p.o.a. 188510 p.o.a.3/4" 188357 p.o.a. 188511 p.o.a.7/8" 188358 p.o.a. 188512 p.o.a.Other prices available on requestSell Category EInsulclampProfessional pipe support systems. Use with Unistrut Channel.Insulclamp – supplied individually or in bags of 10Tube OD Code <strong>List</strong> price1/4" 292400 p.o.a.3/8" 292419 p.o.a.1/2" 292427 p.o.a.5/8" 292435 p.o.a.3/4" 292443 p.o.a.7/8" 292478 p.o.a.Sell Category EGrip LocksDesigned for liquid and gas pipes, including insulation, with space forelectrical cables and condensate tube – box quantity 10Tube OD Code <strong>List</strong> price (10)1/4” & 1/2” 292542 p.o.a.3/8” & 5/8” 292544 p.o.a.1/2” & 7/8” 292546 p.o.a.5/8” & 1 1/8” 292548 p.o.a.Also available: Squeezy Fit Clamps Pipe Hangers. Quick Positioning Clips Studding Clips.Pipe Saddles Nuts Bolts WashersSell Category GUnistrut ChannelGalvanised Steel Channel – 3 metre lengthsCode <strong>List</strong> price41 x 21 plain 292586 p.o.a.41 x 41 plain 292578 p.o.a.41 x 21 slotted 292590 p.o.a.41 x 41 slotted 292582 p.o.a.Unistrut Cantilever brackets also availableSell Category LCondensing Unit BracketsBrackets are finished in ivory powder coat paint and suppliedwith fixings to mount unit (excl. rawl bolts)Code <strong>List</strong> priceType 1-140 140kg (max) 604399 p.o.a.Type 2-60 60kg (max) 604315 p.o.a.Type 2-90 90kg (max) 604317 p.o.a.Type 2-140 140kg (max) 604319 p.o.a.Wall Fixing BoltsCodeSell Category G<strong>List</strong> priceRawl Bolts M1010 292884 p.o.a.Projection Bolts M1015 292886 p.o.a.Sell Category FUnistrut type Cantilever brackets (pair)Including 750mm vertical rails, 600mmcantilever arms, end caps, unit fixing bolts, and rawl boltsCode <strong>List</strong> priceReady to Go Kit 600mm 601699 p.o.a.Condensate Trays and Security Cages are also availableTools & EquipmentA huge variety of service tools, hand tools, and other equipment areavailable from 17 Service Centres throughout the UK. These include:• Gauges & Manifolds• Electronic Manifolds• Vacuum Pumps• Charging Scales• Recovery Equipment• Multimeters• Inverter Checkers• Pipe Benders• Tube Expanders• Tube Cutters• Flaring Tools• Hand ToolsFor Trade Discounts contact yourlocal Service Centre, or log on towww.hrponline.co.uk4243


Condensate PumpsCables & ElectricalInstallation Accessories, Materials and Tools available from HRP <strong>Ltd</strong> UK. Tel: 0044 (0)1925 837 688.Sell Category CPeristaltic Type (non-tank)Make Model Max Head m Code <strong>List</strong> priceAspen Standard 12 / 2 602094 p.o.a.Aspen Universal 12 / 2 602108 p.o.a.Little Giant PCT-10 14 / 2 601773 p.o.a.Sell Category NSauermann Standard 12 / 2 605606 p.o.a.Sauermann Universal 12 / 2 605610 p.o.a.Sell category EHi-Tuff100 metres Black Code <strong>List</strong> price3 core 1.5mm 190695 p.o.a.4 core 1.5mm 190696 p.o.a.5 core 1.5mm 190697 p.o.a.3 core 2.5mm 190698 p.o.a.4 core 2.5mm 190699 p.o.a.Sell Category CTank TypeMake Model Max Head m Code <strong>List</strong> priceAspen Hi-Lift 1 12.0 602116 p.o.a.Aspen Hi-Lift 2 12.0 602118 p.o.a.Aspen Hi-Flow 1 4.0 602124 p.o.a.Aspen Hi-Flow 2 4.0 602043 p.o.a.Aspen MiniBlanc 10.0 602045 p.o.a.Little Giant VCMA10 3.5 601685 p.o.a.Little Giant VCC20S 4.3 601594 p.o.a.Little Giant VCMA20S 4.3 601683 p.o.a.Little Giant VCMX20S 6.0 601684 p.o.a.Pump House PH0.2L 1.5 601692 p.o.a.Pump House PH0.5L 4.0 601694 p.o.a.Pump House PH2L 4.8 601696 p.o.a.Sell category ESY Braided Sheath100 metres Clear PVC Sheath Code <strong>List</strong> price3 core 1.5mm 190782 p.o.a.4 core 1.5mm 190783 p.o.a.5 core 1.5mm 190784 p.o.a.3 core 2.5mm 190785 p.o.a.4 core 2.5mm 190786 p.o.a.Sell category ELI YCY Screened MulticoreSuitable for Remote Control Wiring Code <strong>List</strong> price2 core screened 0.75mm 190805 p.o.a.3 core screened 0.75mm 190806 p.o.a.5 core screened 0.75mm 190804 p.o.a.7 core screened 0.75mm 190808 p.o.a.Sell Category CSplit/Remote Sensor TypeMake Model Max Head m Code <strong>List</strong> priceAspen* FP1500 8.0 602122 p.o.a.Aspen* FP2100 8.0 602121 p.o.a.Little Giant EC400 12.0 601762 p.o.a.Pump House* DE-05-FD 6.0 601710 p.o.a.Sell Category NSauermann SI2750 6.0 605600 p.o.a.* Fits into 90˚ trunking elbowSell Category JCondensate TubingRef No: Size Max Head m Code <strong>List</strong> priceRTV-1/4 30m x 1/4" clear 602282 p.o.a.RTV-1/4 30m x 1/4" black 602284 p.o.a.RTV-3/8 30m x 3/8" clear 602286 p.o.a.RTV-3/8 30m x 3/8" black 602288 p.o.a.RTV-1/2 30m x 1/2" clear 602290 p.o.a.RTV-1/2 30m x 1/2" black 602292 p.o.a.RTV-1/4-200 200m clear 602300 p.o.a.Sell Category NRTV-3/8-200 200m clear 602310 p.o.a.YY Non-Screened100 metres Grey Code <strong>List</strong> price2 core 0.75mm 190792 p.o.a.3 core 0.75mm 190793 p.o.a.7 core 0.75mm 190795 p.o.a.3 core 2.5mm 190801 p.o.a.4 core 2.5mm 190802 p.o.a.Also available: Cleats, Conduit, Stuffing Glands, Brass Glands, Terminals,and Connector BlocksSell category ESell category AWeatherproof Isolators IP 65Lockable in either 'on' or 'off' Code <strong>List</strong> price20A/5.5kW/4Pole 190684 p.o.a.32A/11kW/4Pole 190686 p.o.a.Important It is the Installer’s responsibility to check compliance with Electrical Regulationswhen selecting cable, components, isolators, and all other electrical equipment.44www.hrponline.co.uk45


RefrigerantsTools & EquipmentHRP leads the way in the supply of refrigerants to theUK industry, in partnership with BOC Refrigerants. HRPprovides a complete range of refrigerants in a varietyof containers, from 1kg cans and dumpy cylinders, to1000kg drums. Hydrocarbon, CO2 and Ammoniarefrigerants are also available to special order.HRP Service Centres are located throughout the UKand hold comprehensive stocks of refrigerantcylinders, plus engineers’ service tools and scales.Owing to the volatility of Refrigerant <strong>Price</strong>s, pleaserefer to www.hrponline.co.uk, or contact your ServiceCentre.HFCKgPer CylHRPCodeSalesCat9.8 238058 GR410A 24.0 238060 G55.0 238062 GHRP Services to Contractorsand EngineersChanging LegislationHRP keeps the industry informed of legislationgoverning the availability of refrigerants, followingthe ban of R22 (Virgin HCFC). Building owners,landlords, leaseholders and tenants are now requiredby law to ensure any equipment is de-gassedproperly, with an audit trail for the removal,reprocessing/destruction of refrigerants.Cylinder TrackingHRP has an online tracking facility for accountcustomers, using bar coding, and referencing siteaddresses with cylinder serial numbers. Customerscan view their Cylinder Register on line, and cancustomise their Register with other reference details,including engineers’ names, etc.Refrigerant Waste RecoverySimplified Procedures – HRP has provided a service forrefrigerant waste for the last twelve years. HRPrecognises that engineers do not like regulations,detest form filling, and have some fear and possiblyignorance of the legislation which now covers Waste.To make life easy, HRP has produced a ConsignmentForm, in association with the Environment Agency,with much of the required information pre-printed,allowing the contractor to follow several easy stepsto comply with the Regulations.HRP provides a comprehensive service of RecoveryCylinders, Delivery & Collection, Forms, responsibilitiesof ‘Transfer Station’, Documentation and Certificates.F-Gas RegulationsEffective 4th July <strong>2011</strong>. If you are involved inrefrigerant charging, evacuation, or waste recovery,you must be qualified to City & Guilds 2079 – coursevacancies are still available at the HRP TechnicalCentre and Training Facility, which is sponsored by<strong>Mitsubishi</strong> <strong>Heavy</strong> <strong>Industries</strong>.HRP as a huge range of tools and equipment for airconditioning engineers, from hand tools and gaugesto electronic scales and vacuum pumps. These areavailable from any of the HRP Service Centres locatedthroughout the UK.Installation Accessories, Materials and Toolsavailable from HRP <strong>Ltd</strong> UK.Tel: 0044 (0)1925 837 688.Part Ref Description Sales Cat. Code <strong>List</strong> <strong>Price</strong>Tube Cutting & Flaring Kit - ITE120-F ITE Tube Cutting & Flaring Kit A 163031 p.o.a.Tube Bending Kit - Hercules Model-S Tube Bender E 165905 p.o.a.Former 3/8" E 165913 p.o.a.Slipper 3/8" E 165921 p.o.a.Former 1/2" E 165948 p.o.a.Slipper 1/2" E 165956 p.o.a.Former 5/8" E 165956 p.o.a.Slipper 5/8" E 165964 p.o.a.Manifold Sets MV12A(1) Manifold 8mm R410A - CPS E 163223 p.o.a.556/1 Digital Manifold - Testo E 168210 p.o.a.560/1 Digital Manf'd +gauge - Testo E 168210 p.o.a.Vacuum Pump - Autoclimate 2509-012 2-Stage 1.3 cfm 220V A 167854 p.o.a.2509-019 2-Stage 4.2 cfm 220V A 167856 p.o.a.2509-020 2-Stage 6.5 cfm 220V A 167857 p.o.a.Vacuum Pump - Robinair 2stage 15401 2 Stage 220V & 110V-60Hz A 167797 p.o.a.15601 2 Stage 220V & 110V-60Hz A 167819 p.o.a.15121A 2 Stage 220V & 110V-60Hz A 167853 p.o.a.Refrigerant Scales - TIF TIF9030 Compact Electronic Scales A 174086 p.o.a.Capacity 100kGRefrigerant Recovery Mmax 240 Promax Minimax 240V F 169010 p.o.a.Mmax 110 Promax Minimax 110V-60Hz F 169012 p.o.a.RG5410A-240 Promax 240V F 169014 p.o.a.RG5410A-110 Promax 110V-60Hz F 169016 p.o.a.Vacuum Gauge - CPS VG-100 CPS LED display E 163156 p.o.a.VG-200 CPS Digital display E 164046 p.o.a.Leak Detector - TIF TIF XP-1A HFC & HCFC Z 174941 p.o.a.TIF883 Sensor tip A 174947 p.o.a.TIF8806B Battery Charger A 174955 p.o.a.46 www.3dair .co.uk47