<strong>ACCUME<strong>AS</strong>URE</strong>TM<strong>AS</strong>-<strong>563</strong>Capacitance Sensor Amplifier (OEM Board)HIGH-PRECISION PROBEAMPLIFIER FORGROUNDED TARGETS12.5mm (0.5")RANGETMThe Accumeasure <strong>AS</strong>-<strong>563</strong> OEM board is intended for Original Equipment Manufacturers that require a single channelcapacitance probe amplifier to measure position of grounded targets. The <strong>AS</strong>-<strong>563</strong> can be rack mounted or freemounted using a pig-tail connector and works with <strong>MTI</strong>I standard or custom single ended (single sensor) probes.FeaturesSub-micron ResolutionInterboard SynchronizationInterchangeable Filter Board10Hz, 500Hz, 1 kHz, 2kHz and 5kHz availableBuilt-in Offset Button with LED IndicatorAllows the user to shift the gap output voltage over a 10VDCrange (Field Calibratable)Adjustable Gain ControlAllows user to shift the slope sensitivity (Field Calibratable)Two Connectors Built-inP2 (50-pin PCB edge connector)P3 (Molex 50-57-9407)EXCEPTIONAL REPEATABILITYHIGH LINEARITYBest for Applications, Such as:Servo-loop Positioning ControlPrecision Dimensional GaugingLens Adjustment/ Focusing ControlFlatness and Profile MeasurementVibration MonitoringShaft Run-out and AnalysisLobing MeasurementBrake Rotor & Spindle RunoutScrew Thread Quality InspectionA worldwide leader in precision measurement solutions


Standard SpecificationsThe following specifications listed are for the "Standard" configuration with 1X range. Custom specifications available.1Measurement Range0 to 12.5mm (0.500inch)2Dynamic Resolution0.000075%/vHz FSR RMS3Linearity±0.02% FSR3Repeatability±0.01% FSRFrequency Response (Factory Selectable)DC to 5kHzWarm-up Up time1 HourTemperature Stability±0.01% FSR/ºC3Time Stability±0.01% FSR/100 hours4Output Signal0 to 10VDCPower ±15VDC (20mV AC ripple), 3.9WOperating Temperature4 to 40ºC (40 to 100ºF)Storage Temperature-15 to 65ºC (5 to 150ºF)5Dimensions (LxWxH)239.27x99.95x21.54mm (9.42x3.94x0.85h)Mass0.198g (0.437lbs)[1] Dependent on probe type selected.[2] 100-5kHz. Equivalent to 0.00167% FSR @500Hz RMS.[3] After 100hours site acclimation, warm up, 20ºC,100kPa,50% (Temperature, Pressure, Humidity).[4] Signal Proportional to probe gap.[5] <strong>Inc</strong>ludes connectors which extend beyond the PCB.Optional AccessoriesP3 Wiring Harness1 Meter Pig TailPower and Analog Out SynchronizationP2 Mating Connector50 Position0.1"(2.54mm) SpacingStandard Probe Sensors (Custom Probes Also Available)CalibratorsCTAILARingPCRILRPCACTRFilter Board One Filter Board <strong>Inc</strong>ludedChoose from:10Hz, 500Hz, 1 kHz, 2kHz or 5kHz<strong>MTI</strong> <strong>Instruments</strong>, <strong>Inc</strong>.325 Washington Avenue ExtensionAlbany, NY 12205-5505PH: +1-518-218-2550OR USA TOLL FREE: 1-800-342-2203FAX: +1- 518-218-2506EMAIL: sales@mtiinstruments.comwww.mtiinstruments.comA subsidiary o f Mechanical Technology, <strong>Inc</strong>. (MKTY)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!