<strong>1500CS</strong> PRECISIONCALIBRATORA portable signal source for calibrating electronicequipment and machinery monitoring systems.▪Voltage <strong>Signal</strong>s ▪ Charge <strong>Signal</strong>s ▪ Machinery Speed <strong>Signal</strong>s▪ Dual outputs ▪ Direct Digital Synthesis ▪ Wide Frequency range▪ 40 Built-in memories ▪ Sweep Generator ▪ Battery poweredNever before have all these features beenavailable in a single instrument


Achieve the highest accuracy with the mostadvanced calibrator ever offeredThe New <strong>1500CS</strong> <strong>Precision</strong> <strong>Calibrator</strong> from <strong>MTI</strong> <strong>Instruments</strong> is the first instrument to combine highprecision voltage and charge mode signal generation in a single portable device. Use the <strong>1500CS</strong> inthe laboratory, in test cells, on the flight line, in the factory, or any place that precision signals arerequired for equipment maintenance or system calibration in the test lab. Initially designed formachinery and gas turbine maintenance, the <strong>1500CS</strong> produces accurate and precise voltage, charge,and speed signals necessary for system testing and calibration. In addition to being easy to use, theportable <strong>1500CS</strong> has a large internal memory to store and recall frequently used settings. The<strong>1500CS</strong> also features an RS-232 interface to allow remote control and programming of the unit.DIRECT DIGITAL SYNTHESIS -The<strong>1500CS</strong> combines the precision of DirectDigital Synthesis with 16 bit digital-to-analogaccuracy to provide state-of-the-artperformance.PRECISION SIGNALS - The <strong>1500CS</strong> provides voltageand charge signals with 0.05% accuracy - rarely foundeven in high-cost laboratory instruments.DUAL CHANNEL OUTPUT - The <strong>1500CS</strong> featurestwo independent signal output channels. Set them fordifferent output levels, wave shapes, frequencies, andphase. For other testing needs you can synchronizethe two channels. This unique capability andflexibility makes testing and calibration fast and easy.FULL FUNCTIONALITY – The <strong>1500CS</strong> produces SINE,SQUARE, TRIANGLE, and PULSE waveforms from 0.1HZ to 100KHz in 0.1 Hz increments. Output levels canrange to 10 volts peak and can also include programmableDC offsets in 0.1 millivolt steps.PRECISION CHARGE SIGNALS areproduced by the <strong>1500CS</strong>. Differential andsingle-ended signals are available tosimulate accelerometers and other chargemode devices.The <strong>1500CS</strong> provides unsurpassed features andcapabilities for calibration and repair personnel


Special functions for machineryand instrumentation systemsTesting and calibrating machinery monitoring and control systems is difficult when vibration, speedand other signals must be simulated simultaneously. The <strong>1500CS</strong> has two output channels to simplifythe testing and calibration process, and they may be synchronized or run independent of each other.Special tachometer and signal phase functions enable versatile test strategies to check balancingsystems, gas turbine engine monitoring systems, and other machinery support equipment.SPEED SIGNAL GENERATION is a snap withthe <strong>1500CS</strong>. Machinery speed signals fromtachometer generators, multi-tooth gears andeven odd tooth generators are easily produced.The signals can also be generated at a fixedratio of the other signal channel to producetrue machinery vibration and speed signals.Tach Generator<strong>Signal</strong>Pulse <strong>Signal</strong>Long Tooth <strong>Signal</strong>VARRIABLE PHASE between the two outputssignals is easily adjusted using the <strong>1500CS</strong>controls. Use this feature to calibratebalancing and other data acquisition systems.SYNCHRONIZED SWEEPS are useful whentesting a variety of system performanceparameters. Sweeps are produced by the <strong>1500CS</strong>between a user specified range of frequencies andover a user programmed period of time. Set theSWEEP TIME, the START and STOP frequencies,and then press GO.CHANNEL ACHANNEL B0 DegreesPhase90 DegreesPhaseCHARGE OUTPUT is used to simulate thesignals from piezoelectric accelerometers.Either Single-ended or Differential signals areavailable to calibrate and test vibration circuitsin machinery monitoring systems. A wide rangeof charge signals may be produced at constantand varying frequencies.THE JOG FUNCTION is a unique feature ofthe <strong>1500CS</strong> that permits small changes to manyof the control parameters. Use the JOGfeature to slowly vary the signal frequency todetermine filter response or vary the signalamplitude in increments to determine systemgain.Remarkable functionality and accuracy in an easy to use instrument


Designed to improve productivityThe <strong>1500CS</strong> is a tool that improves productivity as well as ensuring equipment and system accuracy.From the high visibility protective boot and the internal signal setting memory to the easy to usekeyboard interface, the <strong>1500CS</strong> has features to make the job easier.MEMORY for PRODUCTIVITY – All signal settings can besaved and retrieved from the <strong>1500CS</strong>’s 40 location memoryto reduce programming and test time, and to ensure testrepeatability.PORTABLE - The <strong>1500CS</strong> can be used anyplace. It issmall, lightweight, portable, and operates from internalNiMH batteries or the included charger/power supply.DESIGNED FOR RUGGED USE - The <strong>1500CS</strong> isdesigned for the factory and shop environment. The spillproofkeypad, the bright protective boot and the backlighteddisplay all make the <strong>1500CS</strong> reliable in thetoughest working environments.EASY TO USE - The <strong>1500CS</strong> guides users thruthe process of programming the instrument. Allsettings including signal type, amplitude, andfrequency are defined using the keypad. “Soft”function keys on the keypad assume differentfunctions depending upon the mode of operationlending added flexibility to the instrument.Support AccessoriesThe <strong>1500CS</strong> is complimented by a number of accessories designed to ease the task of calibrating andtesting your equipment. Included in the list of accessories is software package specificallydeveloped to help you program, control and realize the most benefit from your <strong>1500CS</strong>.DIGITAL CONTROL INTERFACE –The<strong>1500CS</strong> includes an RS-232 interface.Optional software allows setup, operation,maintenance and calibration of the unit viathis port.CONNECTION CABLES – Several differentcables are available for connecting directly tocharge amplifiers, and other machinerymonitoring equipment. Consult with your <strong>MTI</strong><strong>Instruments</strong> representative for all availableoptions.


<strong>1500CS</strong> SpecificationsChannel AWaveform: Sine WaveVoltage Range0 to 9.9999 Volts pkCharge Range0 to 9,999.9 pC pkVoltage Resolution0.1 mVCharge Resolution0.1 pCLevel TypesRMS, peak or pk-pk unitsFreq. Range0.1 Hz-99999.9 HzDistortion . 0.1 Hz to 10 kHz - 0.25%10 kHz to 100 kHz- 0.75%Frequency Accuracy of setting ±0.0005%Level Set Accuracy of setting 0.05% typical, 0.10% maxWaveform: Square WaveVoltage Range0 to 9.9999 Volts pkCharge Range0 to 9,999.9 pC pkVoltage Resolution0.1 mVCharge Resolution0.1 pCLevel TypesRMS, peak or pk-pk unitsFreq. Range0.1 Hz - 20 kHzRise/Fall Time(10% - 90%) ±1.5 µsec.AsymmetryLess than 5% at 10 kHzOvershoot Less than 5%Level Set Accuracy of setting 0.05% typical, 0.10% maxWaveform: Triangle WaveVoltage Range0 to 9.9999 Volts pkCharge Range0 to 9,999.9 pC pkVoltage Resolution0.1 mVCharge Resolution0.1 pCLevel TypesRMS, peak or pk-pk unitsFreq. Range0.1 Hz - 20 kHzLevel Set Accuracy of setting 0.05% typical, 0.10% maxWaveform: Saw-Tooth WaveVoltage Range0 to 9.999 Volts pkCharge Range0 to 9,999.9 pC pkVoltage Resolution0.1 mVCharge Resolution0.1 pCLevel TypesRMS, peak or pk-pk unitsFreq. Range0.1 Hz - 20 kHzLevel Set Accuracy of setting 0.05% typical, 0.10% maxDC OutputVoltage Range0 to 9,999.9 mV DC full scaleLevel Set Accuracy of setting 0.05% typical, 0.10% maxResolution0.1 mVOutput ConnectorsConnector Impedance50 ohmsVoltage ConnectorBNCFull Differential Charge Connector MS3102A-10SL-3PSingle Ended Charge Connector50 Ohm MicroDotOther FeaturesControls and featuresUser Display4 Line x 16 character LCDEL backlight for readabilityComputer PortRS232 for remote control,programming, and calibrationRJ-12 connectorBattery Charger PortFor battery charging andoperation. 115 VAC powerKey Pad FunctionsNumbers 0 through 9Function Keys 4(functions change depending upon operating mode)On/OffMomentary Hold “soft” buttonSet-Up Memory40 locations to save settingsfor all outputs and functionsSave SettingsSave program setups (40 max)Dimensions 3.5"H, 19"W, 13"DPowerOperates from 115 VAC, 50-60HzApprox 5 watts.Battery Pack – NiMH, size AA (qty 4)ImpedanceConnectorChannel BWaveform: Sine WaveVoltage Range0 to 9.9999 Volts PkResolution0.1 mVLevel TypesRMS, peak or pk-pk unitsFreq. Range0.1 Hz-99,999.9 HzDistortion 0.1 Hz to 10 kHz 0.25%10 kHz to 100 kHz 0.75%Frequency Set Accuracy of setting ±0.0010%Level Set Accuracy of setting 0.10%Waveform: Square WaveVoltage Range0 to 9.9999 Volts PkResolution0.1 mVLevel TypesRMS, peak or pk-pk unitsFreq. Range0.1 Hz - 20 kHzRise/Fall Time(10% - 90%) ±1.5 µsec.AsymmetryLess than 5% at 10 kHzOvershootLess than 5% full scale output)Level Set Accuracy of setting 0.10%6Waveform: Saw-Tooth WaveVoltage Range0 to 9.9999 Volts PkResolution0.1 mVLevel TypesRMS, peak or pk-pk unitsFreq. Range0.1 Hz – 20 kHzLevel Set Accuracy of setting 0.10%50 ohmsBNCChannel B Speed SynthesizerRatio Speed <strong>Signal</strong> Function<strong>Signal</strong> Type Sine, Square, Single pulse, Odd Pulse<strong>Signal</strong> Range0 to 9.999 Volts PkResolution1.0 mVFreq. Range (ratio) 0.1 to 100X Chan A frequency, Step 0.1UnitsRMS, peak, or pk-pkSingle Pulse <strong>Signal</strong> Function<strong>Signal</strong> TypeSine or Square<strong>Signal</strong> Range0 to 9.999 Volts PkResolution1.0 mVPulse Duty Cycle 12% to 100%Freq. Range (ratio) 0.1 to 100X Ch. A frequency, Step 0.1Freq. Range (fixed)1Hz to 100kHzUnitsRMS, peak, or pk-pkOdd Pulse <strong>Signal</strong> FunctionOdd Pulse TypeLong or ShortOdd Pulse Size0 to 999% of Base PulseNumber of Base Pulses between Odd Pulse 1 - 100Freq. Range (ratio) 0.1 to 100X Ch. A frequency, Step 0.1Freq. Range (fixed)1 Hz to 99,999.9 HzRange0 to 9.999 Volts PkResolution1.0 mVVoltage UnitsRMS, peak, or pk-pkWaveformSine waveSpeed <strong>Signal</strong> Sweep FunctionSweep time1 to 999 secStep Size1 SecondUser Controls: Set START Freq, Set STOP Freq,Set SWEEP time, GO, PAUSE,CANCELChannelsA alone or A & B togetherCh. B can be swept with Ch. A if Ch. B frequency is a Ratio<strong>MTI</strong> <strong>Instruments</strong> is a world leader in advanced technologyproducts for manufacturing, computer and aerospaceindustries. <strong>MTI</strong> has gained world-wide recognition with over40 years of experience designing and manufacturingleading-edge products.Contact <strong>MTI</strong> <strong>Instruments</strong> for more information about the<strong>1500CS</strong>.E-mail: pbs@mtiinstruments.comTel: +518-218-2550FAX: +518-218-2506

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!