Schneider Airsystems - Pipeline Installation Manual<br />

To determine the correct pipeline diameter, the following details are required:<br />

� Type of line (stub line or closed circular pipeline - the latter is the better solution.)<br />

� Line length<br />

� Line material<br />

� Capacity of the compressor (flow rate / air requirements of the compressed air<br />

system)<br />

� Number of fittings (angles, outlets, ball valves…)<br />

As a general rule, during design with the Schneider pipeline calculator a working<br />

overpressure of 7 bar, ΔP (max.) 0.2 bar and a flow rate of (max.) 10m/s is assumed.<br />

Tube Manual status 08/2008 Page 2