Diamond Headspace Syringes New Limits in Headspace Analysis

Diamond Headspace Syringes New Limits in Headspace Analysis

Diamond Headspace Syringes New Limits in Headspace Analysis

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>New</strong> <strong>Limits</strong> <strong>in</strong> <strong>Headspace</strong> <strong>Analysis</strong><br />

<strong>Diamond</strong><br />

<strong>Headspace</strong> <strong>Syr<strong>in</strong>ges</strong><br />

• Outstand<strong>in</strong>g reproducibility<br />

ma<strong>in</strong>ta<strong>in</strong>ed dur<strong>in</strong>g temperature<br />

cycl<strong>in</strong>g<br />

• Highest operat<strong>in</strong>g temperature<br />

• Save time and improve analysis<br />

workflow<br />

AUSTRALIA & PACIFIC REGION EUROPE JAPAN USA


<strong>New</strong> potential <strong>in</strong> headspace analysis<br />

Don’t limit your headspace analysis<br />

Previously available headspace syr<strong>in</strong>ges may perform poorly when used at high temperatures or cycled<br />

through high temperature. Common problems experienced with headspace analyses due to poor syr<strong>in</strong>ge<br />

performance <strong>in</strong>clude: syr<strong>in</strong>ge plunger tips fail<strong>in</strong>g; leak<strong>in</strong>g syr<strong>in</strong>ges; needles detach<strong>in</strong>g; additional sample<br />

flush<strong>in</strong>g due to high syr<strong>in</strong>ge carryover; and worst of all, poor reproducibility of results.<br />

Introduc<strong>in</strong>g the new standard <strong>in</strong> headspace syr<strong>in</strong>ges that overcomes these problems.<br />

Outstand<strong>in</strong>g Reproducibility<br />

• SGE’s unique energized plunger tip design ensures a gas tight seal is consistently ma<strong>in</strong>ta<strong>in</strong>ed<br />

provid<strong>in</strong>g outstand<strong>in</strong>g performance (%RSD) with temperature cycl<strong>in</strong>g.<br />

Repeat <strong>in</strong>jection RSD (%)<br />

10%<br />

9%<br />

8%<br />

7%<br />

6%<br />

5%<br />

4%<br />

3%<br />

2%<br />

1%<br />

0%<br />

80 120 80<br />

Syr<strong>in</strong>ge Temperature (°C)<br />

SGE <strong>Diamond</strong> <strong>Headspace</strong> syr<strong>in</strong>ge<br />

Brand X syr<strong>in</strong>ge<br />

Figure 1. RSDs of 5 <strong>in</strong>jections at sequential temperatures us<strong>in</strong>g SGE <strong>Diamond</strong> <strong>Headspace</strong> <strong>Syr<strong>in</strong>ges</strong> compared to another available headspace syr<strong>in</strong>ge brand.<br />

FID response<br />

125000<br />

120000<br />

115000<br />

110000<br />

105000<br />

100000<br />

4.2<br />

4.3<br />

Time (m)<br />

4.4<br />

4.5<br />

SGE 120 ˚C <strong>in</strong>jection 1<br />

SGE 120 ˚C <strong>in</strong>jection 2<br />

SGE 120 ˚C <strong>in</strong>jection 3<br />

SGE 120 ˚C <strong>in</strong>jection 4<br />

SGE 120 ˚C <strong>in</strong>jection 5<br />

Figure 2. Reproducibility of Results with SGE <strong>Diamond</strong> <strong>Headspace</strong> Syr<strong>in</strong>ge across 5 <strong>in</strong>jections<br />

at 120 °C<br />

System: Agilent 6890 GC with CTC PAL<br />

autosampler with <strong>Headspace</strong> system<br />

Phase: 25 m 250 µm ID 0.25 µm BPX5<br />

column<br />

Sample: 10 ppm Hexane:Water sample<br />

<strong>in</strong>cubated at 80 °C<br />

Initial Temp: 40 °C<br />

Rate 1: 20 °C / m<strong>in</strong>ute<br />

F<strong>in</strong>al Temp: 100 °C<br />

Detector Type: FID, 250 °C<br />

Carrier Gas: He<br />

Injection Port Temp: 140 °C


Highest Operat<strong>in</strong>g Temperature<br />

• SGE’s <strong>Diamond</strong> <strong>Headspace</strong> <strong>Syr<strong>in</strong>ges</strong> ma<strong>in</strong>ta<strong>in</strong> performance up to 150 °C and cont<strong>in</strong>ue to<br />

perform with temperature cycl<strong>in</strong>g result<strong>in</strong>g <strong>in</strong> an <strong>in</strong>creased headspace syr<strong>in</strong>ge lifetime.<br />

<strong>Headspace</strong> Syr<strong>in</strong>ge Cycl<strong>in</strong>g Performance<br />

% Initial Plunger Force<br />

100<br />

75<br />

50<br />

25<br />

0<br />

Step 1 - 25 C Step 2 - 110 C Step 3 - 150 C Step 4 - 110 C Step 5 - 25 C<br />

Figure 3. <strong>Headspace</strong> Syr<strong>in</strong>ge Plunger Seal Temperature Cycl<strong>in</strong>g Performance.<br />

SGE <strong>Diamond</strong> <strong>Headspace</strong><br />

Competitor A<br />

Competitor B<br />

• Improved sample and solvent compatibility:<br />

- The PTFE plunger tip <strong>in</strong> <strong>Diamond</strong> <strong>Headspace</strong> <strong>Syr<strong>in</strong>ges</strong> enables the use of a broader range of<br />

samples and solvents compared with polymers used <strong>in</strong> plungers of other high temperature<br />

syr<strong>in</strong>ges, this provides greater flexibility for your headspace analyses and a longer last<strong>in</strong>g syr<strong>in</strong>ge.<br />

Save Time and Improve <strong>Headspace</strong> <strong>Analysis</strong> Workflow<br />

• Improved workflow:<br />

- SGE’s <strong>Diamond</strong> <strong>Headspace</strong> syr<strong>in</strong>ges ma<strong>in</strong>ta<strong>in</strong> performance up to 150 °C enabl<strong>in</strong>g you to improve<br />

your workflow by avoid<strong>in</strong>g the need for transfer l<strong>in</strong>es or a dedicated headspace autosampler.<br />

• Save time:<br />

- <strong>Diamond</strong> <strong>Headspace</strong> syr<strong>in</strong>ges do not require extended equilibration time unlike other<br />

headspace syr<strong>in</strong>ges.<br />

- Reduced carryover of <strong>Diamond</strong> <strong>Headspace</strong> syr<strong>in</strong>ges reduces the need for flush<strong>in</strong>g and<br />

wash<strong>in</strong>g of syr<strong>in</strong>ges.<br />

There is no dead space on the SGE syr<strong>in</strong>ge.<br />

Sample is completely swept from the barrel.<br />

This image also shows SGE's unique energized<br />

plunger tip which ensures reproducibility<br />

by ma<strong>in</strong>ta<strong>in</strong><strong>in</strong>g a complete seal aga<strong>in</strong>st the<br />

<strong>in</strong>ternal surface of the syr<strong>in</strong>ge.<br />

SGE <strong>Diamond</strong> <strong>Headspace</strong>Syr<strong>in</strong>ge<br />

Competitor Syr<strong>in</strong>ge<br />

Unique energized<br />

plunger tip<br />

Unswept volume<br />

Figure 4. SGE <strong>Diamond</strong> <strong>Headspace</strong> and competitor’s syr<strong>in</strong>ge shown with<br />

plungers at the zero position.


BR-0416-C_RevD © SGE Analytical Science Pty Ltd 08/2012<br />

Order<strong>in</strong>g Information<br />

Part No. Capacity<br />

(mL)<br />

For Thermo RSH Systems<br />

AUSTRALIA & PACIFIC REGION<br />

SGE Analytical Science Pty Ltd<br />

7 Argent Place, R<strong>in</strong>gwood<br />

Victoria 3134 Australia<br />

Toll Free: 1800 800 167<br />

Tel: +61 (0) 3 9837 4200<br />

Fax: +61 (0) 3 9874 5672<br />

Email: support@sge.com<br />

JAPAN<br />

SGE Japan Inc<br />

RK CUBE 3F 6-85, Ohta-machi<br />

Naka-Ku, Yokohama-shi<br />

Kanagawa 231-0011 Japan<br />

Tel: +81 45 222 2885<br />

Fax: +81 45 222 2887<br />

Email: japan@sge.com<br />

Needle Length<br />

(mm)<br />

Needle Gauge Needle OD<br />

(mm)<br />

Needle ID<br />

(mm)<br />

EUROPE<br />

SGE Europe Ltd<br />

European Head Office<br />

1 Potters Lane<br />

Kiln Farm Milton Keynes<br />

MK11 3LA United K<strong>in</strong>gdom<br />

Toll Free: 00800 2790 8999<br />

Toll Free Fax: 00800 2626 2609<br />

Tel: +44 1908 568 844<br />

Fax: +44 1908 566 790<br />

Tel France: +33 1 69 29 80 90<br />

Fax France: +33 1 69 29 09 25<br />

Tel Germany: +49 (0) 6155 / 60746 0<br />

Fax Germany: +49 (0) 6155 / 60746 50<br />

Email: europe@sge.com<br />

Needle Tip Replacement<br />

Plunger P/N<br />

008155 1.0 65 23 0.63 0.32 Side Hole 032841<br />

008655 2.5 65 23 0.63 0.32 Side Hole 032846<br />

For CTC Analytics Platforms<br />

008131 1.0 56 23 0.63 0.15 Side Hole 031841<br />

008136 1.0 56 26 0.47 0.15 Side Hole 031841<br />

008631 2.5 56 23 0.63 0.15 Side Hole 031851<br />

008636 2.5 56 26 0.47 0.15 Side Hole 031851<br />

Look for the diamond mark-<br />

the mark of syr<strong>in</strong>ge brilliance.<br />

UNITED STATES OF AMERICA<br />

SGE Incorporated<br />

2007 Kramer Lane<br />

Aust<strong>in</strong> Texas 78758 USA<br />

Toll Free: (800) 945 6154<br />

Tel: +1 512 837 7190<br />

Fax: +1 512 836 9159<br />

Email: usa@sge.com