Nordic catalogue - Watts Industries

Nordic catalogue - Watts Industries

Nordic catalogue - Watts Industries

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

COMPONENTS FOR UNDERFLOOR HEATINGHOT PRESSED BRASS MANIFOLDPreassembled manifold CPRFLFLMR. Return manifolds series 822MM. Two ball shut-off valves series 210. Two end-piecesfor manifolds series 823MP complete with drain cocks series 238, air vent valves series MVDand immersion thermometers serie TB. Centre distance between side outlet connections:50 mm. N.B.: inspection box not included in the supply.Article number Size Outlet UnitCPRFL54TM3 1.1/4" F 3 - 3/4" M 1CPRFL54TM4 1.1/4" F 4 - 3/4" M 1CPRFL54TM5 1.1/4" F 5 - 3/4" M 1CPRFL54TM6 1.1/4" F 6 - 3/4" M 1CPRFL54TM7 1.1/4" F 7 - 3/4" M 1CPRFL54TM8 1.1/4" F 8 - 3/4" M 1CPRFL54TM9 1.1/4" F 9 - 3/4" M 1CPRFL54TM10 1.1/4" F 10 - 3/4" M 1CPRFL54TM11 1.1/4" F 11 - 3/4" M 1CPRFL54TM12 1.1/4" F 12 - 3/4" M 139DBalancing of circuits branched from manifolds series CPRFLReliable readjustment of flow ratesfrom the various branches to thedesign valve is a performance characteristicwhich “makes the difference”as regards correct operationof the system, above all inradiant panel systems.For uniform heat comfort, eachcircuit should give up the correctquantity of thermal energy, and fromthis point-of-view the flow rate parameteris a very important factor.The new modular FLMR manifolds,size 1” and 1.1/4” for building updistributors with any number of connections,provide a valid solution :in fact, a real flow meter, incorporatedin the setting device, is installedin each delivery branch.End-pieces, for holdingaccessories series 823MPStop devicesRETURNAir vent valvesseries MVDSUPPLYElectrothermic actuatorsseries 22CSingle modularmanifoldsseries 822MMMountingbracketsType 840MTherefore the use of a measuringinstrument is not required nor it isnecessary to determine analyticallythe setting position on diagrams.It is merely necessary to open orclose until the flow meter shows therequired flow rate.ImmersionthermometerAutomatic temperature control ispossible on manifolds of the returnline by using silent running electothermicunits (Type. 22C).Drain valveseries 238Single modular manifoldsseries 822MM completewith flow meter series FLMRNO

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!