10.07.2015 Views

The universe at your fingertips. - Fotona

The universe at your fingertips. - Fotona

The universe at your fingertips. - Fotona

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Clean and fully intactdentinal tubules afterlaser tre<strong>at</strong>ment.<strong>The</strong> <strong>universe</strong> <strong>at</strong> <strong>your</strong> <strong>fingertips</strong>.<strong>The</strong> l<strong>at</strong>est technology dental laser systemsDentistry’s two best wavelengths Er:YAG and Nd:YAGScanner-readySupreme clinical resultsUnm<strong>at</strong>ched simplicity of useHard and Soft TissueDental Lasers


No Compromise - Dentistry's Two BestLaser Wavelengths<strong>The</strong> LightWalker models AT and DT come standard with dentistry’s two most effective laser wavelengths: Er:YAG and Nd:YAGfor no-compromise dentistry with a touch of the control screen.Universal Laser SystemIt is a well-established fact th<strong>at</strong> different dental procedures require different laser wavelengths. Wavelength is importantbecause specific body tissues interact in different ways depending on the particular laser source. With the choice of twocomplementary wavelengths (in terms of their effect on tissues) LightWalker comes very close to being a “universal” laser.Practically all laser-assisted dental tre<strong>at</strong>ments can be performed with either the most highly absorbed Er:YAG laser wavelengthor the most homogeneously absorbed Nd:YAG laser wavelength.TwinLight® Tre<strong>at</strong>ment Concept<strong>The</strong> combin<strong>at</strong>ion of the two best wavelengths in one laser system enables practitioners to perform not only singlewavelengthbut also dual-wavelength (TwinLight®) tre<strong>at</strong>ments. Utilizing both wavelengths in a tre<strong>at</strong>ment makes optimumuse of the unique laser-tissue interaction characteristics of each wavelength. For example, Nd:YAG laser energy is superiorfor coagul<strong>at</strong>ion and deep disinfection while Er:YAG is uniquely efficient <strong>at</strong> abl<strong>at</strong>ing hard and soft tissues. Combined, they candram<strong>at</strong>ically improve the outcome of laser assisted tre<strong>at</strong>ments, guaranteeing maximum safety and efficacy.Highest Power and Largest Pulse Dur<strong>at</strong>ionRangeIn LightWalker, both “gold standard” laser wavelengthsare produced by solid crystal lasers th<strong>at</strong> can outperformany diode or other dental laser in terms of peak power andthe range of pulse dur<strong>at</strong>ions.Fast efficient cutting with unm<strong>at</strong>ched p<strong>at</strong>ientcomfortNo other lasers cut as fast as LightWaker lasers for hardand soft tissues.Precise tissue surgery with simultaneousdisinfection<strong>The</strong> homogeneous absorption of the Nd:YAG laser in softtissue results in precise tissue vaporiz<strong>at</strong>ion with simultaneouscoagul<strong>at</strong>ion. Additionally, up to 1000× higher pulsepower compared to other lasers provides superior disinfection.ABLATION SPEEDIn enamel (10 -2 mm 3 /sec)0161284016,6LightWalker Er:YAGAbl<strong>at</strong>ion speed: Er:YAG vs. high-speed drill and other lasers12Highspeed Handpiece5,7StandardLaserDISINFECTION EFFICACYIn endodontic tre<strong>at</strong>ment (%)091%Nd:YAG 1064 nm63%Diode 810 nmMeasured <strong>at</strong>a dentinal depthof 1000 µm13%Diode 980 nmDisinfection efficacy: Nd:YAG vs. other lasers


Virtually Unlimited Applic<strong>at</strong>ionsLightWalker lasers have the most coprehensive list of clinical applic<strong>at</strong>ions of any dental laser in the world. With the availabilityof both tipped and tipless handpieces, <strong>your</strong> clinical options are endless. LightWalker offers the highest standard ofdental tre<strong>at</strong>ment, and <strong>at</strong> the same time simplicity of use in:• Endodontics• Periodontics• Soft Tissue Surgery• Implantology• Conserv<strong>at</strong>ive dentistry• Aesthetic tre<strong>at</strong>mentsPresettings for over 40 Different Applic<strong>at</strong>ions<strong>The</strong> LightWalker touchscreen offers a simple menu of pre-programmed laser tre<strong>at</strong>ments. You pick the tre<strong>at</strong>ment and thelaser autom<strong>at</strong>ically sets <strong>your</strong> optimum starting parameters. With easy-to-follow protocols and touch-of-a-button tre<strong>at</strong>mentsettings, you’ll be able to perform every dental procedure with confidence and high success r<strong>at</strong>es, bringing in extra incometo <strong>your</strong> practice along the way. You can even upgrade the AT model to perform aesthetic skin tre<strong>at</strong>ments (where permittedby local practice regul<strong>at</strong>ions).<strong>The</strong> four main applic<strong>at</strong>iongroupsComfort window forroutine daily proceduresAdvanced window to finetune specific proceduresConvenience in UseEasy-to-use touch screenLightWalker has an easy-to–use color touch screen with anadjustable tilt and 80 customizable presettings which covermore than 40 different applic<strong>at</strong>ions.Easy access spray/he<strong>at</strong>ed w<strong>at</strong>er reservoir<strong>The</strong> integr<strong>at</strong>ed spray w<strong>at</strong>er container means th<strong>at</strong> you don’thave to rely on any w<strong>at</strong>er mains outlet, making <strong>your</strong> lasersystem uniquely mobile and hassle-free. <strong>The</strong> container ishandily loc<strong>at</strong>ed <strong>at</strong> the back of the system for easy refillingaccess. Additionally, the w<strong>at</strong>er is he<strong>at</strong>ed to body temper<strong>at</strong>ure,avoiding cold sensitivity reactions during procedures.P<strong>at</strong>ented weightless OPTOflex arm(available with LightWalker AT)LightWalker’s unique and p<strong>at</strong>ented OPTOflex Er:YAG articul<strong>at</strong>edarm is perfectly balanced during use, makinghandpieces completely weightless in <strong>your</strong> hand. OPTOflexallows a full range of motion and a maximum degreeof control as it makes maneuvering the handpiece muchsmoother, which improves tre<strong>at</strong>ment precision and ease.Wireless footswitch (optional)LightWalker also has a wireless footswitch which avoids unnecessarytangling of electric cables on <strong>your</strong> practice floor.


TwinLight ® Endodontic Tre<strong>at</strong>ment<strong>The</strong> <strong>Fotona</strong> TwinLight®Endodontic Tre<strong>at</strong>ment(TET) successfully addressestwo major disadvantages ofclassical chemo-mechanicaltre<strong>at</strong>ments procedures: theinability to clean and debridean<strong>at</strong>omically complex root canal systems and to deeplydisinfect dentinal walls.This powerful photon-induced photacoustic streamingmethod, which is available only with <strong>Fotona</strong> lasers, isequally effective for final w<strong>at</strong>er rinsing prior to obtur<strong>at</strong>ion.In the second step, the deeply penetr<strong>at</strong>ing Nd:YAG laserwavelength is utilized to decontamin<strong>at</strong>e dentinal walls upto 1000 µm deep. In this step, the high peak-pulse powerof the Nd:YAG laser plays an important role as it inducesmaximum temper<strong>at</strong>ure pulsing for elimin<strong>at</strong>ing bacteria.In the first step of the TwinLight® tre<strong>at</strong>ment, a revolutionaryphotacoustic streaming method is employed, which usesthe power of the Er:YAG laser to cre<strong>at</strong>e non-thermalphotoacoustic shock waves within the cleaning anddebriding solutions introduced in the canal. Following thistre<strong>at</strong>ment, the canals and subcanals are left clean and thedentinal tubules are free of a smear layer.Following endodonticlaser tre<strong>at</strong>ments withphotacoustic streaming,there is no smear layeraround the opening ofthe l<strong>at</strong>eral canal.In the first step, Er:YAG laserlight cleans and debrides thecanals and subcanals.In the second step,the Nd:YAG laser deeplydisinfects the dentinal walls.Top-Of-<strong>The</strong>-Line Easy-To-Use HandpiecesTitanium TechnologyLightWalker uses advanced titanium handpieces which provideultim<strong>at</strong>e durability for constant handling and frequentsteriliz<strong>at</strong>ion.disposal. Wh<strong>at</strong>'s more, LightWalker AT has an autom<strong>at</strong>ichandpiece detection system which knows exactly whichhandpiece you have selected and autom<strong>at</strong>ically sets theappropri<strong>at</strong>e laser parameters.Er:YAG<strong>The</strong> tipped and tipless Er:YAG handpieces have an integr<strong>at</strong>edair/w<strong>at</strong>er spray for additional p<strong>at</strong>ient comfort. <strong>The</strong>Er:YAG handpieces also have a quick disconnect systemfor gre<strong>at</strong>er convenience and easier steriliz<strong>at</strong>ion.Nd:YAG<strong>The</strong> Nd:YAG handpieces are now more convenient thanever. With LightWalker AT you have two constantly availablehandpieces with two different fiber diameters <strong>at</strong> <strong>your</strong>


TwinLight ® Periodontal Tre<strong>at</strong>mentTwinLight® Periodontal Tre<strong>at</strong>ment(TPT) is a minimallyinvasive periodontal diseasetherapy incorpor<strong>at</strong>ing dentistry’stwo best laser wavelengths.<strong>The</strong> Twinlight® approachenables wavelength-optimized tre<strong>at</strong>ments for periodontaltherapy (such as WPT * ), which cre<strong>at</strong>e the optimalconditions for healing periodontal tissues by removingthe diseased epithelial lining of the periodontal pocket,removing microbial biofilm and calculus from the rootsurface and sealing the pocket after tre<strong>at</strong>ment with a stablefibrin clot.<strong>The</strong> TwinLight® Periodontal Tre<strong>at</strong>ment approach givesgeneral dentists the confidence to tre<strong>at</strong> their p<strong>at</strong>ents’moder<strong>at</strong>e-to-severe periodontal disease the laser way,without scalpels and sutures.*WPT is a therapy developed by <strong>Fotona</strong>'s partner Lares Research.Step 1: theNd:YAG laserremoves thediseasedepitheliallining andimprovesaccess to theroot surface.Step 2:Er:YAG isused tothoroughlyremovecalculusfrom theroot surface.Step 3:Nd:YAGlaser energyis used tocoagul<strong>at</strong>eand leavea stablefibrin clot.Scanner-Modefor Future Applic<strong>at</strong>ionsLightWalker AT is the first dental laser system in the worldth<strong>at</strong> incorpor<strong>at</strong>es scanning laser technology. <strong>Fotona</strong>’s forward-lookingin-house R&D team has designed a systemwith innov<strong>at</strong>ive technological solutions to accommod<strong>at</strong>efuture dental needs.<strong>The</strong> LightWalker's Er:YAG scanner will allow the practitionerto perform tre<strong>at</strong>ments involving otherwise unachievablep<strong>at</strong>terns. This has the potential to revolutionize dental fieldssuch as implantology, conserv<strong>at</strong>ive dentistry and apicoectomy.Unm<strong>at</strong>ched PrecisionLightWalker AT is an Er:YAG scanner-ready system. <strong>The</strong>scanner will provide consistent and even abl<strong>at</strong>ion in hardand soft tissue over a 5×5 mm area. <strong>The</strong> speed and consistencyof abl<strong>at</strong>ion with a scanner is virtually impossible toachieve by using any other tool.Walk into the Future with LightWalkerLightWalker technology will finally enable practitioners toutilize the most important fe<strong>at</strong>ure of laser light, its weightlessness.Using a scanner, laser light can be swiftly andaccur<strong>at</strong>ely moved across the surface of tre<strong>at</strong>ed tissues.Samples of easily achievable scanning p<strong>at</strong>terns in hard tissue drillingand cutting.


TouchWhite ® Laser Assisted ToothWhitening<strong>The</strong> TouchWhite® p<strong>at</strong>entpending tooth whiteningmakes use of the fact th<strong>at</strong> theEr:YAG laser wavelength hasan absorption peak in w<strong>at</strong>erwhich is the major componentof aqueous bleachinggels. This elimin<strong>at</strong>es the need for any additional absorbingparticles in the bleaching gels. More importantly, takinginto account thermal burden consider<strong>at</strong>ions, the Touch-White® procedure represents the most effective and leastinvasive laser-assisted tooth whitening method possible.Due to its high absorption in bleaching gels, the Er:YAGlaser beam is fully absorbed in the gel and does notEr:YAG laseraStandard laserWith TouchWhite® whitening only the gel is he<strong>at</strong>ed (a) while withstandard laser whitening the entire tooth is he<strong>at</strong>ed (b).bpenetr<strong>at</strong>e to the hard tissue or the pulp. All of the laserenergy is thus effectively used for the he<strong>at</strong>ing of the gel.<strong>The</strong>re is no direct he<strong>at</strong>ing of the dental tissue and the pulp,as is the case with other laser-assisted whitening methods.<strong>The</strong>re is also no risk of accidentally damaging the hard dentaltissue as the laser fluence of every laser pulse is set to besignificantly below the abl<strong>at</strong>ion threshold for dental tissues.As a consequence, the procedure can be performed witha minimal undesirable thermal burden on the tooth, andthe tooth whitening speed can be safely increased by 5 – 10times.WHITENING TIME (s)010008006004002000TouchWhiteStandard laserWithout laserTouchWhite® Tooth Whitening substantially shortensthe whitening process.LightWalkerRangeEr:YAGNd:YAGSystem AT DT ST-EBasic Standard Advanced Basic Standard AdvancedPower20 W8 W 10 W 18 W 8 W 10 W 18 WIntegr<strong>at</strong>ed spray ü ü ü ü üEnergy 1500 mJ 500 mJ 500 mJ 900 mJ 500 mJ 500 mJ 900 mJOper<strong>at</strong>ional modesMAX, QSP (up to 120 Hz)SSP, MSP, SP, LP, VLPSSP, MSP, SP, LP, VLPSSP, MSP, SP, LP, VLPOptical delivery OPTOflex 7–mirror arm 7–mirror armPower 15 W 8 WOper<strong>at</strong>ional modesMSP, SP, VLP15 ms, 25 msMSP, SP, VLPOptical delivery Dual fiber system Single fiber systemAT models additionaly include scanner-ready mode, autom<strong>at</strong>ic handpiece detection, quick-disconnect Er:YAG handpieces, advancableand disposable Nd:YAG fiber feed handpieces, he<strong>at</strong>ed w<strong>at</strong>er spray for enhanced p<strong>at</strong>ient comfort, and optional green pilot beam.


Supreme Clinical ResultsShorter and More Effective Tre<strong>at</strong>mentsWith LightWalker, procedures are typically shorter, easier toperform and more effective. Laser tre<strong>at</strong>ments are by n<strong>at</strong>ureminimally invasive, and Lightwalker takes this concept to anew level.P<strong>at</strong>ient ComfortWorking with LightWalker is less stressful for the p<strong>at</strong>ientbecause pain and bleeding are minimal if any. LightWalkerlasers are so gentle for cavity prepar<strong>at</strong>ions and mostsoft-tissue procedures th<strong>at</strong> p<strong>at</strong>ients rarely require anyanaesthetic. Laser light allows you to work in a non-contactway and without drilling noise, which is far more comfortablefor p<strong>at</strong>ients, especially children. LightWalker also allowsyou to achieve simultaneous disinfection and prevention ofcross-contamin<strong>at</strong>ion.Unm<strong>at</strong>ched Flexibility<strong>The</strong> Nd:YAG laser source is ideal for root canal disinfection,soft tissue crown lengthening and numerous other applic<strong>at</strong>ions.And LightWalker’s Er:YAG laser is comp<strong>at</strong>ible witha set of over 20 specialized fiber tips, expertly designed tooffer an additional range of lucr<strong>at</strong>ive, high quality tre<strong>at</strong>mentsin endodontics, periodontics and implant recovery,areas you may otherwise have to refer out to specialists.Courtesy of MDATG, LLCIntact collagen fibres afterlaser tre<strong>at</strong>ment.Preserved collagen fibrils ofthe intertubular dentin <strong>at</strong> theentrances to the dentinal tubules.After endodontic laser tre<strong>at</strong>mentthe dentinal tubules are disinfectedand fully open.<strong>The</strong> Technology Behind theBest Dental Laser in the World<strong>The</strong> development of LightWalker is based on <strong>Fotona</strong>’s 45 years of experience in laser technology. <strong>The</strong> system hastechnologically superior laser elements th<strong>at</strong> make it the highest performance, best made laser system in the world:Variable Square Pulse (VSP) Technology<strong>Fotona</strong>’s VSP technology sets the precision and safety ofdental laser tre<strong>at</strong>ments on a higher level. <strong>Fotona</strong>’s squareshapedlaser pulses avoid standard laser technologies’slow rise and even longer fall in pulse power. VSP ensuresultim<strong>at</strong>e p<strong>at</strong>ient comfort in all <strong>your</strong> tre<strong>at</strong>ments and unrivaledease-of-use.Energy Feedback Control<strong>The</strong> laser system incorpor<strong>at</strong>es a sophistic<strong>at</strong>ed double channelsafety structure for energy regul<strong>at</strong>ion which contributesto procedure safety. <strong>The</strong> laser output energy is constantlyregul<strong>at</strong>ed by a signal from two energy meters.Quantum Square Pulse (QSP)By avoiding the hard tissue debris cloud the laser abl<strong>at</strong>esmore efficiently and with gre<strong>at</strong>er precision in <strong>Fotona</strong>’s p<strong>at</strong>entpeding QSP mode because the laser beam is not affectedby the debris. By being able to abl<strong>at</strong>e more efficiently,the edges of individual cr<strong>at</strong>ers are virtually straight, whichprovides higher levels of precision and preserv<strong>at</strong>ion in hardtissue tre<strong>at</strong>ments.Tissue Effect Graphical Interface (TeGI)<strong>The</strong> Tissue Effect Graphical Interface (TeGI) provides agraphical represent<strong>at</strong>ion of the laser tissue effect, maximizingease-of-use and shortening the learning curve.


LightWalker Intern<strong>at</strong>ional RecognitionPride institute - Best of ClassTechnology Award 2011Dentistry Today - Top 100Products 2011Pedi<strong>at</strong>ric Dentistry Congress, Okt 2011, NetherlandsDr. Giovanni Olivi: “<strong>The</strong> role of lasers in pedi<strong>at</strong>ric dentistry”DGL Congress, Okt 2011, GermanyDr. Thorsten Kuypers: “Die perfekte Wellenlänge für dieperfekte Indik<strong>at</strong>ion – welche Wellenlänge macht für michSinn? Welche Kombin<strong>at</strong>ionen brauche ich zum Erfolg?”Journal of the Laser and Health Academy Vol. 2011Dr. Norbert Gutknecht et al.: “A Novel Er:YAG Laser-AssistedTooth Whitening Method”Dr. Tomaz Lipoglavsek, Dr. Boris Gaspirc: “TwinLight ®Periodontal Tre<strong>at</strong>ment”Dr. Norbert Gutknecht et al.: “A Novel Quantum Square Pulse(QSP) Mode Erbium Dental Laser”Intern<strong>at</strong>ional Magazine of Laser Dentistry, Vol. 3, Issue 2/2011Dr. Jugoslav Jovanovic: “TouchWhite ® Er:YAG laser-assistedTooth Whitening”Global Leader for over 45 YearsSince 1964 <strong>Fotona</strong> has set industry standards of excellencein producing high-tech laser systems for medicine,communic<strong>at</strong>ions, industry, and defense. Consequently<strong>Fotona</strong> is a globally recognized leader and pioneer inthe innov<strong>at</strong>ion, development and manufacture of lasersystems.High Technology -Made in EuropeAs one of the top manufacturers of medical laser systems, ourcommitment to st<strong>at</strong>e-of-the-art, in-house production setsus apart from the competition, which typically outsourcesthe production process. <strong>Fotona</strong>’s in-house manufacturingand stringent testing of all components, in compliancewith applicable intern<strong>at</strong>ional standards, ensures th<strong>at</strong> oursystems are of the highest quality, reliability and durability.Best Training and SupportTo get the most out of <strong>your</strong> LightWalker system, ourpractitioner workshops, coorganized with the Laser andHealth Academy, provide hands-on demonstr<strong>at</strong>ions ofour lasers from intern<strong>at</strong>ional clinical experts. <strong>Fotona</strong> alsoworks closely with other leading educ<strong>at</strong>ional authoritiesin the field of laser dentistry to offer additional highlevel training opportunities to help you on <strong>your</strong> p<strong>at</strong>h tobecoming a top laser specialist.Committed to engineering:<strong>The</strong> Highest Performance, Best Made Laser Systems in the World.In-House TechnologySince 1964www.lightwalkerlaser.comwww.fotona.cominfo@lightwalkerlaser.cominfo@fotona.com<strong>Fotona</strong> is certified to: ISO 9001:2008, EN ISO 13485:2003,MDD 93/42/EEC, ANNEX II.3, ISO 13485:2003 (CMDCAS),GMP according to FDA regul<strong>at</strong>ions89090 CE ENG/6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!