Datasheet<strong>Agilent</strong> <strong>34405A</strong> <strong>Multimeter</strong>5.5 Digit Dual Display, Benchtop DMMMore Capabilities at a Value PriceData SheetFeatures120000 counts resolution16 built-in measurement functionsincluding temperature and capacitance0.025% DC voltage accuracyUSB 2.0SCPI compatible<strong>Agilent</strong> IO Library Suite and DMMIntuilink connectivity software includedAffordable and Feature-RichMeasurement ToolThe <strong>34405A</strong> represents the latest memberin the <strong>Agilent</strong>’s DMM family and thisexpands <strong>Agilent</strong>’s offerings in theelectronics measurement tools. It providesa broad range of features andmeasurement functions such as DCvoltage, DC current, true-RMS AC voltageand AC current, 2-wire resistance,frequency, diode test and continuitywhich are designed to meet generalindustrial needs. Furthermore, it canmeasure temperature ranging from -80 o Cto 150 o C. The true value is more evidentwith its capability to measure capacitanceranging from 1000pF to 10000mF. <strong>Agilent</strong><strong>34405A</strong> also improves efficiency andaccuracy with its 6 built-in mathoperations: Null, dBm, dB, MinMax, Limitand Hold.Quick Connection to the PC with USB 2.0InterfaceFor those with a need to control and takepreset measurements with a PC, the builtinUSB 2.0 interface provides an easy androbust connection between the PC andDMM. The USB interface that is compliantwith the TMC-488.2 Standards, worksseamlessly with <strong>Agilent</strong> Connectivitysoftware and can be controlled remotelyvia industry standard SCPI commands orthrough DMM Intuilink Connectivitysoftware. IVI-COM and LabVIEW driversare included to ensure an easy integrationwith different programming environments.Bright Display, Fast Reading Speed andConfiguration StorageWhen high throughput and productivityare the priority, <strong>Agilent</strong> <strong>34405A</strong> VFD dualdisplay feature allows users to take morethan one measurement and display themsimultaneously on the front panel. Forspeed critical applications, <strong>Agilent</strong> <strong>34405A</strong>can take up to 19 readings/sec at 4.5digits resolution directly to the PC. Inaddition, the user can configure and storecomplete instrument setups and recallthem at anytime from any of the four builtinstoring states.Rugged and ReliableThe <strong>34405A</strong> is designed and testedaccording to major Safety and RegulatoryStandards. In addition, the shockabsorbing bumpers is designed to preventphysical damage from your day-to-dayuse.Go to the WEB for more information on<strong>Agilent</strong>’s DMM. Visit www.agilent.com<strong>Amplicon</strong>.comIT and Instrumentation for industrySales: +44 (0) 1273 570 220 Website: www.amplicon.com Email: sales@amplicon.com


DatasheetDC SPECIFICATIONS [1]ACCURACY ± (% of reading + % of range)Temperature CefficientFUNCTION RANGE [2] BURDEN VOLTAGE INPUT IMPEDENCE [3] 23 o C ± 5 o C28 o C - 55 o CTEST CURRENT OR1 Year0 o C - 18 o CVOLTAGE 100.000 mV - 10.0 MW\2% 0.025+0.008 0.0015+0.00051.00000 V - 10.0 MW\2% 0.025+0.006 0.0010+0.000510.0000 V - 10.1 MW\2% 0.025+0.005 0.0020+0.0005100.000 V - 10.1 MW\2% 0.025+0.005 0.0020+0.00051000.00 V - 10.0 MW\2% 0.025+0.005 0.0015+0.0005RESISTANCE 100.000 W 1.0 mA - 0.05+0.008 [4] 0.0060+0.00081.00000 kW 0.83 mA - 0.05+0.005 [4] 0.0060+0.000510.0000 kW 100 mA - 0.05+0.006 [4] 0.0060+0.0005100.000 kW 10.0 mA - 0.05+0.007 0.0060+0.00051.00000 MW 900 nA - 0.06+0.007 0.0060+0.000510.0000 MW 205 nA - 0.25+.005 0.0250+0.0005100.000 MW 205 nA||10MW - 2.00+0.005 0.3000+0.0005CURRENT 10.0000 mA < 0.2 V - 0.05+0.015 0.0055+0.0005100.000 mA < 0.2 V - 0.05+0.005 0.0055+0.00051.00000 A < 0.5 V - 0.20+0.007 0.0100+0.000510.0000 A < 0.6 V - 0.25+0.007 0.0150+0.0005CONTINUITY 1000 W 0.83 mA - 0.05+0.005 0.0050+0.0005DIODE TEST [5] 1.0000 V 0.83 mA - 0.05+0.005 0.0050+0.0005AC SPECIFICATIONS [1]ACCURACY ± (% of reading + % of range)Temperature CefficientFUNCTION RANGE [6] FREQUENCY1 Year23 o C ± 5 o C0 o C - 18 o C28 o C - 55 o CTRUE-RMS 100.000 mV 20 Hz - 45 Hz 1.0+0.1 0.02+0.02AC VOLTAGE [7] 45 Hz - 10 kHz 0.2+0.1 0.02+0.0210 kHz - 30 kHz 1.5+0.3 0.05+0.0230 kHz - 100 kHz [8] 5.0+0.3 0.10+0.021.00000 V to 750.00 V 20 Hz - 45 Hz 1.0+0.1 [9] 0.02+0.0245 Hz - 10 kHz 0.2+0.1 0.02+0.0210 kHz - 30 kHz 1.0+0.1 0.05+0.0230 kHz - 100 kHz [8] 3.0+0.2 [10] 0.10+0.02TRUE-RMS 10.0000 mA 20 Hz - 45 Hz 1.5+0.1 0.02+0.02AC CURRENT [11] 100.000 mA 45 Hz - 1 kHz 0.5+0.1 0.02+0.0210.0000 A 1 kHz - 10 kHz [12] 2.0+0.2 0.02+0.02FREQUENCY [13] 100 mV to 750 V < 2 Hz 0.18+0.003 0.005< 20 Hz 0.04+0.003 0.00520 Hz - 100 kHz [14] 0.02+0.003 0.005100 kHz ~ 300 kHz [15] 0.02+0.003 0.00510 mA to 10 A < 2 Hz 0.18+0.003 0.005< 20 Hz 0.04+0.003 0.00520 Hz ~ 10 kHz [14] 0.02+0.003 0.005TEMPERATURE and CAPACITANCE SPECIFICATIONS [1]ACCURACY ± (% of reading + % of range)Temperature CefficientFUNCTION RANGE TEST CURRENT, etc.1 Year23 o C ± 5 o C0 o C - 18 o C28 o C - 55 o CTEMPERATURE -80 o C - 150 o C 5 kW thermistor probe Probe accuracy + 0.2 o C 0.002 o C- 110.0 o F - 300.0 o F 5 kW thermistor probe Probe accuracy + 0.4 o F 0.0036 o FCAPACITANCE 1.000 nF 0.75 mA 2.0+0.8 0.02+0.00110.00 nF 0.75 mA 1.0+0.5 0.02+0.001100.0 nF 8.3 mA 1.0+0.5 0.02+0.0011.000 mF - 100.0 mF 83 mA 1.0+0.5 0.02+0.0011000 mF 0.83 mA 1.0+0.5 0.02+0.00110,000 mF 0.83 mA 2.0+0.5 0.02+0.001[1] Specifications are for 30 minutes warm-up, 5 1/2 digit resolution and calibration temperature 18 o C - 28 o C.[2] 20% over range on all ranges except 1000Vdc.[3] Input Impedence is in paralleled with capacitance < 120 pF.[4] Specifications are 2-wire ohms using Math Null. If without Math Null, add 0.2 W additional error.[5] Specifications are for the voltage measured at the input terminals only.[6] 20% over range on all range except 750 Vac.[7] Specifications are for sinewave inputs > 5% of range. Maximum crest factor : 3 at full scale.[8] Additional error to be added as frequency > 30kHz and signal input < 10% of range. 30kHz ~ 100kHz: 0.003% of full scale per kHz.[9 For input < 200V rms.[10] For input < 300V rms.[11] For 12A terminal, 10A dc or ac rms continuous, > 10A dc or ac rms for 30 seconds ON and 30 seconds OFF.[12] For 1A and 10A ranges, the frequency is verified for less than 5kHz.[13] Specifications are for half-hour warm-up, using 0.1 second aperture. The frequency can be measured up 1Mhz as 0.5V signal to 100mV/1V ranges.[14] For 20Hz ~ 10kHz, the sensitivity is AC input current from 10% to 120% of range except where noted.[15] For 100Hz ~ 300kHz, the sensitivity will be 12% ~120% of range except 750V range.2<strong>Amplicon</strong>.comIT and Instrumentation for industrySales: +44 (0) 1273 570 220 Website: www.amplicon.com Email: sales@amplicon.com


DatasheetOPERATING SPECIFICATIONSSYSTEM SPEEDFUNCTION DIGITS READING SPEED [1] (sec) [2](sec) [3](sec) [4]OVER USB [5]FUNCTION CHANGE RANGE CHANGE AUTO RANGE READING SPEEDDCV, DCI 5 1/2 15/s8/s0.6 0.7 2.24 1/2 70/s 19/sACV, ACI 5 1/2 2.5/s4 1/2 2.5/s5.0 2.2 6.1 1/sFREQUENCY [6] 5 1/2 9/s4 1/2 9/s7.0 2.5 6.1 1/s[1] Reading rate of the A/D converter.[2] Time to change from 2-wire resistance to this specified functions and to take at least one reading in 4.5 digit using the SCPI “FUNC” and “READ?” commands.[3] Time to change one range to the next higher range and to take at least one reading in 4.5 digit using the SCPI “FUNC” and “READ?” commands.[4] Time to automatically change one range and to take at least one reading in 4.5 digit using SCPI “CONF AUTO” and “READ?” commands.[5] Number of measurements per second that can be read through USB using SCPI “ READ?” command.[6] Reading rate depend on signal frequency > 10Hz.SUPPLEMENTAL MEASUREMENT SPECIFICATIONSDC VOLTAGEMeasuring Method:Sigma Delta A-to-D converterInput Resistance:10MW\2% range (typical)Input Protection:1000V on all rangesRESISTANCEMeasuring Method:2-wire OhmsOpen-circuit voltage:Limited to < 5VInput Protection:1000V on all rangesDC CURRENTShunt Resistance:0.1W to 10W for 10mA to 1.2A ranges0.01W for 12A rangeInput Protection:Front Panel 1.25A, 500V fuse for I terminalInternal 15A, 600V fuse for 12A terminalCONTINUITY/DIODE TESTMeasuring Method:Uses 0.83mA\0.2% constant current source, < 5V open circuit voltageResponse Time:70 samples/second with audible toneContinuity Threshold:10W fixedInput Protection:1000VTEMPERATUREMeasurement Method:2-wire Ohms measurement of 5kW thermistor sensor (YSI 4407) withcomputer conversionAuto-ranging measurement, no manual range selectionInput Protection:1000VMEASUREMENT NOISE REJECTIONCMRR (Common Mode Rejection) for 1kW unbalance LO leadDC120 dBAC70 dBNMR (Normal Mode Rejection) For 60 Hz (50Hz) \ 0.1%5 1/2 digit 65 dB (55 dB)4 1/2 digit 0 dBAC VOLTAGEMeasurement Method:AC coupled true-RMS - measure the ac component with up to 400 Vdc bias anyrangeCrest Factor:Maximum 5:1 at full scaleInput Impedence:1MW\2% in parallel with < 100pF of all rangesInput Protection:750Vrms on all rangesAC CURRENTMeasuring Method:DC coupled to the fuse and current shunt, AC coupled true-RMS measurement(measure the AC component only)Shunt Resistance:0.1W to 10W for 10mA to 1.2A range0.1W for 12A rangeInput Protection:Externally accessible 1.25A, 500V fuse for I terminalInternally replaceable 15A, 600V fuse for 12A terminalFREQUENCYMeasurement Method:Reciprocal counting technique. AC coupled input using AC voltage function.Signal Level:10% of range to full scale input on all rangesAuto or manual range selectionGate Time:0.1 second or 1 period of the input signal, whichever is longer.Input Protection:750Vrms on all rangesMATH FUNCTIONSNull, dBm, dB, Min/Max/Avg, Hold, Limit TestTRIGGER and MEMORYSingle trigger, 1 reading memoryREMOTE INTERFACEUSB 2.0 full speed, USBTMC class device (GPIB over USB)PROGRAMMING LANGUAGESCPI, IEEE-488.1, IEEE-488.23<strong>Amplicon</strong>.comIT and Instrumentation for industrySales: +44 (0) 1273 570 220 Website: www.amplicon.com Email: sales@amplicon.com


Datasheet<strong>Agilent</strong> <strong>34405A</strong> <strong>Multimeter</strong>: Versatile andlow cost solution for benchtop testing.5.5 digit dual display increases productivityand throughput in troubleshooting.Use the Up-Down keys to select the desiredmeasurement range. Just press Shift -> Autokey to switch measurement rangeautomatically.Superior value with a broad range offunctions, which includes the temperatureand capacitance measurements.Connect the supplied test leads to the InputTerminals to start your measurements.Selecting the secondary display measurements.Math functions and utility menu that allow usersto take reference measurements (ie. Min/Maxvalue and etc.) and store the measurementsetups from the front panel.5<strong>Amplicon</strong>.comIT and Instrumentation for industrySales: +44 (0) 1273 570 220 Website: www.amplicon.com Email: sales@amplicon.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!