140PC...PCB pressure sensor - Sensortechnics

140PC...PCB pressure sensor - Sensortechnics

140PC...PCB pressure sensor - Sensortechnics

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>140PC</strong>...-<strong>PCB</strong> SeriesSignal conditioned precision <strong>pressure</strong> transducersPERFORMANCE CHARACTERISTICS(unless otherwise noted V S= 8.00 ±0.01 V, R L> 100 kΩ, t amb= 25°C)Operating <strong>pressure</strong>C haracteristicsM in.T yp.Max.2vacuum gage devices141PC01G-<strong>PCB</strong>141PC05G-<strong>PCB</strong>141PC15G-<strong>PCB</strong>141PC30G-<strong>PCB</strong>141PC100G-<strong>PCB</strong>3differentialdevices142PC01D-<strong>PCB</strong>142PC05D-<strong>PCB</strong>142PC15D-<strong>PCB</strong>142PC30D-<strong>PCB</strong>142PC100D-<strong>PCB</strong>142PC150D-<strong>PCB</strong>3absolutedevices142PC15A-<strong>PCB</strong>142PC30A-<strong>PCB</strong>142PC100A-<strong>PCB</strong>3<strong>pressure</strong>/vacuum devices143PC01D-<strong>PCB</strong>143PC03D-<strong>PCB</strong>143PC05D-<strong>PCB</strong>143PC15D-<strong>PCB</strong>Zero<strong>pressure</strong> offset141PC.../142PC...-PC B143PC...-<strong>PCB</strong>4Fullscale span141PC.../142PC...-PC B143PC...-<strong>PCB</strong>-1-5-15-30-100000000000-1-2.5-5-150.953.454.952.451.003.505.002.5000000151530100150153010012.55151.053.555.052.55Fullscale output5.906.006.10Outputat lowest specified <strong>pressure</strong>143PC...-<strong>PCB</strong>1.005Non-linearity and hysteresis (BSL)0.1 0. 56ThermaleffectsCombined offsetand span (0 to 70°C)all 1 psi devicesall others±1.5±0.57Longterm stability±0. 1±3.0±1.0Unitpsig(vacuum)Responsetime (10 to 90%)0.1mspsid(g)psiapsid(g)Currentconsumption4.5mARadiated, radio frequency electromagneticfield immunity (RFI) EN6100-4-3 grade 3,80 to 1000 MHz,80 % AMC (1 KHz)V%FSO10V/ mSpecification notes:1.2.3.4.5.6.7.Proof <strong>pressure</strong> is the maximum <strong>pressure</strong> which may be applied without causing damage to the sensing element.The output signal of all 141PC...-<strong>PCB</strong> devices is proportional to the vacuum applied to port A, relative to port B, e. g. theoutput signal increases when <strong>pressure</strong> is applied to port B relative to port A.The output signal of all 142PC...D-<strong>PCB</strong> and 143PC...D-<strong>PCB</strong> devices is proportional to the <strong>pressure</strong> applied to port A, relativeto port B, e.g. the output signal increases when vacuum is applied to port B relative to port A.Full scale span is the algebraic difference between the positive full scale output and the zero <strong>pressure</strong> offset.Non-linearity refers to the Best Straight Line fit measured for offset <strong>pressure</strong>, full scale <strong>pressure</strong> and 1/2 full scale <strong>pressure</strong>.Thermal effects tested and guaranteed from 0 - 70°C relative to 25°C. All specifications shown are relative to 25°C.Change in output after one year or 1 million <strong>pressure</strong> cycles.E / 11554 / A2/3www.first-<strong>sensor</strong>.comwww.<strong>sensor</strong>technics.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!