10.07.2015 Views

140PC...PCB pressure sensor - Sensortechnics

140PC...PCB pressure sensor - Sensortechnics

140PC...PCB pressure sensor - Sensortechnics

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>140PC</strong>...-<strong>PCB</strong> SeriesSignal conditioned precision <strong>pressure</strong> transducersFEATURES· 1 to 150 psi absolute, gage ordifferential <strong>pressure</strong>· 1...6 V output· Output ratiometric to supply voltage· Precision temperature compensatedand calibrated· EMC-proofSERVICENon-corrosive, non-ionic working fluids,such as dry air and dry gasesSPECIFICATIONSMaximum ratingsELECTRICAL CONNECTIONSupply voltage7...16 VMaximum load currentSourceSinkTemperature limitsStorageOperatingCompensated10 mA5 mA-55 to 100°C-40 to 85°C0 to 70°C<strong>140PC</strong>...-<strong>PCB</strong>+VsVout7 V to 16 V(NOM 8.00 V)Lead temperature(10 sec. soldering)Humidity limitsPressure inlets only300°C0 - 98 %RH-VsVProof <strong>pressure</strong> 1All 1 psi, 3 psi, 5 psi devicesAll 15 psi devicesAll 30 psi devicesAll 100 psi devicesAll 150 psi devices20 psi30 psi60 psi150 psi200 psiE / 11554 / A1/3www.first-<strong>sensor</strong>.comwww.<strong>sensor</strong>technics.com


<strong>140PC</strong>...-<strong>PCB</strong> SeriesSignal conditioned precision <strong>pressure</strong> transducersPERFORMANCE CHARACTERISTICS(unless otherwise noted V S= 8.00 ±0.01 V, R L> 100 kΩ, t amb= 25°C)Operating <strong>pressure</strong>C haracteristicsM in.T yp.Max.2vacuum gage devices141PC01G-<strong>PCB</strong>141PC05G-<strong>PCB</strong>141PC15G-<strong>PCB</strong>141PC30G-<strong>PCB</strong>141PC100G-<strong>PCB</strong>3differentialdevices142PC01D-<strong>PCB</strong>142PC05D-<strong>PCB</strong>142PC15D-<strong>PCB</strong>142PC30D-<strong>PCB</strong>142PC100D-<strong>PCB</strong>142PC150D-<strong>PCB</strong>3absolutedevices142PC15A-<strong>PCB</strong>142PC30A-<strong>PCB</strong>142PC100A-<strong>PCB</strong>3<strong>pressure</strong>/vacuum devices143PC01D-<strong>PCB</strong>143PC03D-<strong>PCB</strong>143PC05D-<strong>PCB</strong>143PC15D-<strong>PCB</strong>Zero<strong>pressure</strong> offset141PC.../142PC...-PC B143PC...-<strong>PCB</strong>4Fullscale span141PC.../142PC...-PC B143PC...-<strong>PCB</strong>-1-5-15-30-100000000000-1-2.5-5-150.953.454.952.451.003.505.002.5000000151530100150153010012.55151.053.555.052.55Fullscale output5.906.006.10Outputat lowest specified <strong>pressure</strong>143PC...-<strong>PCB</strong>1.005Non-linearity and hysteresis (BSL)0.1 0. 56ThermaleffectsCombined offsetand span (0 to 70°C)all 1 psi devicesall others±1.5±0.57Longterm stability±0. 1±3.0±1.0Unitpsig(vacuum)Responsetime (10 to 90%)0.1mspsid(g)psiapsid(g)Currentconsumption4.5mARadiated, radio frequency electromagneticfield immunity (RFI) EN6100-4-3 grade 3,80 to 1000 MHz,80 % AMC (1 KHz)V%FSO10V/ mSpecification notes:1.2.3.4.5.6.7.Proof <strong>pressure</strong> is the maximum <strong>pressure</strong> which may be applied without causing damage to the sensing element.The output signal of all 141PC...-<strong>PCB</strong> devices is proportional to the vacuum applied to port A, relative to port B, e. g. theoutput signal increases when <strong>pressure</strong> is applied to port B relative to port A.The output signal of all 142PC...D-<strong>PCB</strong> and 143PC...D-<strong>PCB</strong> devices is proportional to the <strong>pressure</strong> applied to port A, relativeto port B, e.g. the output signal increases when vacuum is applied to port B relative to port A.Full scale span is the algebraic difference between the positive full scale output and the zero <strong>pressure</strong> offset.Non-linearity refers to the Best Straight Line fit measured for offset <strong>pressure</strong>, full scale <strong>pressure</strong> and 1/2 full scale <strong>pressure</strong>.Thermal effects tested and guaranteed from 0 - 70°C relative to 25°C. All specifications shown are relative to 25°C.Change in output after one year or 1 million <strong>pressure</strong> cycles.E / 11554 / A2/3www.first-<strong>sensor</strong>.comwww.<strong>sensor</strong>technics.com


<strong>140PC</strong>...-<strong>PCB</strong> SeriesSignal conditioned precision <strong>pressure</strong> transducersOUTLINE DRAWING59.852.430.0port A(high <strong>pressure</strong>)18.310.714.09.131.53 terminals0.56 diam.2 x 5.08 typ.3,43.2 diam.2 x mounting holes4.8diam.NOM 6.0pinconnection1 +Vsmass: 20 g 2 -Vsdimensions in mm3 Vout22.712312.6ORDERING INFORMATIONOperating<strong>pressure</strong>part numberVacuum gage devices0...-1psig141PC01G-<strong>PCB</strong>0...-5psig141PC05G-<strong>PCB</strong>0...-15psig141PC15G-<strong>PCB</strong>0...-30psig141PC30G-<strong>PCB</strong>0...-100psig141PC100G-<strong>PCB</strong>D ifferential / gage devices0...1psid(g)142PC01D-<strong>PCB</strong>0...5psid(g)142PC05D-<strong>PCB</strong>0...15psid(g)142PC15D-<strong>PCB</strong>0...30psid(g)142PC30D-<strong>PCB</strong>0...100psid(g)142PC100D-<strong>PCB</strong>0...150psid(g)142PC150D-<strong>PCB</strong>Absolutedevices0...15psia142PC15A-<strong>PCB</strong>0...30psia142PC30A-<strong>PCB</strong>0...100psia142PC100A-<strong>PCB</strong>P ressure/vacuum devices0...±1psid(g)143PC01D-<strong>PCB</strong>0...±2.5psid(g)143PC03D-<strong>PCB</strong>0...±5psid(g)143PC05D-<strong>PCB</strong>0...±15psid(g)143PC15D-<strong>PCB</strong>Other <strong>pressure</strong> ranges and calibrations are available on request. Please contact First Sensor.First Sensor reserves the right to make changes to any products herein. First Sensor does not assume any liability arising out of the applicationor use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.E / 11554 / A3/3www.first-<strong>sensor</strong>.comwww.<strong>sensor</strong>technics.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!