11.07.2015 Views

sensors - Jumo

sensors - Jumo

sensors - Jumo

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

JUMO GmbH & Co. KGDelivery address: Mackenrodtstraße 14,36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607E-mail:mail@jumo.netInternet: www.jumo.netJUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow - Essex CM20 2DY, UKPhone: +44 1279 63 55 33Fax: +44 1279 63 52 62E-mail: sales@jumo.co.ukInternet: www.jumo.co.ukJUMO Process Control, Inc.8 Technology BoulevardCanastota, NY 13032, USAPhone: 315-697-JUMO1-800-554-JUMOFax: 315-697-5867E-mail: info@jumo.usInternet: www.jumo.usJUMO dTRANS CR 02Transmitter/controller for conductivity, TDS,resistance, standard signals and temperatureMeetsrequirements ofUSPData Sheet 202552Page 1/19Brief descriptionThe JUMO dTRANS CR 02 is a compact, modular instrument. It is highly flexible (for example3 slots for optional boards) and capable of performing a wide range of tasks. The main input ofthe JUMO dTRANS CR 02 is used for <strong>sensors</strong> for measuring electrolytic conductivity, specificresistance, or the TDS value. Both conductive two-electrode and four-electrode cells can beconnected to the instrument. The second analog input (compensation input) is designed forresistance thermometers Pt100 and Pt1000, NTC/PTC or standard signals 0(4) - 20 mA or 0 -10 V. The two binary inputs can be used either as initiators for actions (e.g. HOLD, keyboardinhibit) or when connecting pulse generators (for example impeller <strong>sensors</strong>) for flow-ratemeasurement. The high-contrast graphic display allows for several options including display ofinput signal with numbers or as bar graph. Parameters are displayed in plain text for easilycomprehensible and reliable operation.The JUMO dTRANS CR 02 can be used as a two-point or three-point controller, a three-pointmodulating controller, or as a continuous controller. All controller outputs can be configured toP, PI, PD or PID action. The software for the controllers includes parameter set selection, a mathmodule and more.A setup program is available for convenient configuration via PC. The instrument can beintegrated into a data network by means of an RS422/485 or Profibus DP interface. Screwterminals on the back are used for the electrical connection.Some applications:- Industrial and process water.- Drinking and well water.- Pure, ultra-pure and pharmaceutical water (e.g. as per USP, Ph. Eur., WFI).- Cleaning processes in pharmaceutical applications (four-electrode cells in conjunction withmeasuring range selection).JUMO dTRANS CR 02Type 202552JUMO dTRANS CR 02in surface-mounted enclosureBlock diagramOptional boards- Analog input- Analog output- Relay- Double relay- Profibus DP and RS422/485interface- Datalogger function with RS485Special features■ A choice of display visualizations: largenumbers, bar graph or tendency (trend)display■ Integrated calibration routines:Cell constant, temperature coefficient■ Math and logic module■ Calibration logbook■ Integrated washing timer to control thecleaning equipment■ 13 operator languages integrated; seeorder details■ Setup program provides: convenientprogramming, system documentation■ RS422/485 interface (optional)■ Profibus-DP interface (optional)■ Flush-mounted instrument - just 96 mm x48 mm x 95 mm■ Electrode monitoring can be activated■ Flow-rate measurement2011-08-11/00541512


JUMO GmbH & Co. KGDelivery address: Mackenrodtstraße 14,36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607E-mail:mail@jumo.netInternet: www.jumo.netJUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow - Essex CM20 2DY, UKPhone: +44 1279 63 55 33Fax: +44 1279 63 52 62E-mail: sales@jumo.co.ukInternet: www.jumo.co.ukJUMO Process Control, Inc.8 Technology BoulevardCanastota, NY 13032, USAPhone: 315-697-JUMO1-800-554-JUMOFax: 315-697-5867E-mail: info@jumo.usInternet: www.jumo.usData Sheet 202552Page 2/19Boardsab(1) PSU board(2) Main board(a) Optional board 1(b) Optional board 2(c) Optional board 3c12Functional descriptionThe instrument is a modularly designedindicator/controller for use in both simple anddemanding control tasks. It can be integratedinto the PLC via interfacesTo make programming and operation easy, allparameters are clearly assigned to levels anddisplayed in plain text. Operation is protectedby a code word. Operation can be adapted onan individual basis because parameters canbe generally enabled or assigned to theprotected area.A setup program for the PC is available as amore convenient configuration option, ratherthan using the instrument keypad.User dataDisplay modesThe following display modes are available:Normal displayIn this display method the measurementsappear in numbers, as usual.Large displayThis method uses the complete displayheight.Tendency displayPSU board (1)This board is always fitted in the instrumentand no variations are possible.The board includes the following items:- The power supply for theJUMO dTRANS CR 02.- The power supply for external 2-wiretransmitters.- 2 relays with changeover contacts.Main board (2)This board can not be changed subsequently!The main board (CR) has:- The main input for connecting a two- orfour-electrode conductivity cell.- The secondary input for connecting atemperature sensor Pt100, Pt1000, aresistance transmitter or a standard signal0(4) - 20 mA or 0 - 10 V.- 2 binary inputs.- The setup interface (for PC interfaceadapter).Optional board (1), (2) or (3)These boards are combinable and can beordered in the following versions:- 1 analog input- 1 continuous output- 1 relay (changeover)- 2 relays (NO with common pin)- 1 Triac (1 A)- 1 Foto-MOS relay (0.2 A)The following boards can only be placed inslot 3, either:- Modbus / Jbus- Profibus- DataloggerUp to 8 parameters that are frequentlychanged by the user can be combined in theuser level under "User data" (via setupprogram only).Displays and controls(8)(1) (2) (3) (4) (5)(7)(1) Binary outputs (relays)Output active if symbol is visible.(2) Binary inputInput closed if symbol is visible.(3) Keyboard inhibitKeys locked if symbol is visible.(4) Alarm messageALARM (flashing): Broken sensor oroverrange, etc.AL R1: Controller monitoring alarm fromcontroller channel 1.AL R1: Controller monitoring alarm fromcontroller channel 2.CALIB: Calibration mode active.CALIB (flashing): Calibration timerelapsed.(5) Output modeMAN.: Manual mode active.HOLD: Hold mode active.(6) Top displayMeasured value and unit of the variableset by parameter "Top display".(7) Bottom displayMeasured value and unit of the variableset by parameter "Bottom display".(8) Operating modeMEASURING: Standard measuringmode is active.(6)In this display a symbol is added to thenumerical value to indicate the direction andspeed of change for the measurement value.This can be very useful for optimizing thecontroller, for example.From left to right:Fast, medium and slow rise, steady,slow, medium and fast fall.Bar graphIn this display mode, it only takes a glance toascertain the range for the currentmeasurement.Any scale can be used for the bar graph.Tendency curve (data monitor)The ring buffer contains about 100 measuringpoints. The sampling and storage rates canbe adjusted.Flow rate quantityIf an input has been configured for flow-ratemeasurement, this display can be accessed.2011-08-11/00541512


JUMO GmbH & Co. KGDelivery address: Mackenrodtstraße 14,36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607E-mail:mail@jumo.netInternet: www.jumo.netJUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow - Essex CM20 2DY, UKPhone: +44 1279 63 55 33Fax: +44 1279 63 52 62E-mail: sales@jumo.co.ukInternet: www.jumo.co.ukJUMO Process Control, Inc.8 Technology BoulevardCanastota, NY 13032, USAPhone: 315-697-JUMO1-800-554-JUMOFax: 315-697-5867E-mail: info@jumo.usInternet: www.jumo.usData Sheet 202552Page 6/19Measurement ranges / cell constantsThis modern instrument features a much higher dynamic range on the input side thanconductivity cells are able to control physically or chemically. The measurement range of theinstrument must therefore be coordinated with the operating range of the cell.Sample measuring ranges for combinations with two-electrode cellsCell constant (K)Recommended/practical measurementscope(depending on the conductivity cell)0.01 1/cm 0.05 µS/cm - 20 µs/cm0.1 1/cm 1 µS/cm - 1000 µs/cm1.0 1/cm 0.01 mS/cm - 100 ms/cm3.0 1/cm 0.1 mS/cm - 30 ms/cm10.0 1/cm 0.1 mS/cm - 200 ms/cmExampleTo conduct a measurement in the range from 10 µS/cm to 500 µS/cm,select a conductivity cell with a cell constant K = 0.1 1/cm.Configure the unit µS/cm on the instrument without places after the decimal.Combination with four-electrode cells and two-electrode cells with cellconstant differing from the grid aboveThis case requires a more in-depth use of the instrument technology. Both the uncompensatedand the temperature compensated measurement scope must be considered.The uncompensated measurement scope of the instrument may be calculated according to thefollowing formula:Measurement scope = 0.1µs/cm x cell constant (K) to 2500 mS x cell constant (K).After consideration of the temperature compensation range, approximately the followingcompensated measurement scope remains:Measurement scope = 0.1µs/cm x cell constant (K) to 1250 mS x cell constant (K).Cell constant (K)Measurement scope based on instrument(temperature-compensated)0.01 0.001 µS/cm - 1.25 ms/cm0.1 0.01 µS/cm - 12.5 ms/cm1.0 0.1 µS/cm - 125 ms/cm3.0 0.3 µS/cm - 375 ms/cm10.0 0.1 mS/cm - 1250 ms/cmIt may be assumed that the measurement scope of the instrument is always greater than therecommended or practically usable range of the conductivity cell that is used.The smaller range (instrument or conductivity cell) determines the maximum usable range.ExampleWhat measurement scope can the instrument cover with a specified cell constant?The specified cell constant is K=0.4The measurement scope of the instrument = 0.1 µS/cm x 0.4 1/cm to 1250 mS/cm x 0.4 1/cm ➝0.04 µS/cm - 500 mS/cm2011-08-11/00541512


JUMO GmbH & Co. KGDelivery address: Mackenrodtstraße 14,36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607E-mail:mail@jumo.netInternet: www.jumo.netJUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow - Essex CM20 2DY, UKPhone: +44 1279 63 55 33Fax: +44 1279 63 52 62E-mail: sales@jumo.co.ukInternet: www.jumo.co.ukJUMO Process Control, Inc.8 Technology BoulevardCanastota, NY 13032, USAPhone: 315-697-JUMO1-800-554-JUMOFax: 315-697-5867E-mail: info@jumo.usInternet: www.jumo.usData Sheet 202552Page 7/19Technical dataInputs (main board)Main input Measuring range/control range Accuracy Effect of temperatureµS/cm 0.000 - 9.99900.00 - 99.99000.0 - 999.90000 - 9999mS/cm 0.000 - 9.99900.00 - 99.99000.0 - 999.90000 - 9999k x cm 0.000 - 9.99900.00 - 99.99000.0 - 999.90000 - 9999M x cm 0.000 - 9.99900.00 - 99.99000.0 - 999.90000 - 99991 Selectable in °F.Resistance thermometer inputs (optional board) 0.6% of range + 0.3 µS x cellconstant (K) 0.6% of range + 0.3 µS x cellconstant (K) 0.6% of range + 0.3 µS x cellconstant (K) 0.6% of range + 0.3 µS x cellconstant (K)0.2%/10K0.2%/10K0.2%/10K0.2%/10KSecondary inputTemperature Pt100/1000 -50-250°C 1 0.25% of range 0.2%/10KTemperature NTC/PTC0.1 - 30 kEntry via tablewith 20 value pairs 1.5% of range0.2%/10KStandard signal 0(4) - 20 mA or 0 - 10 V 0.25% of range 0.2%/10KResistance transmitterMinimum: 100 +/- 5 0.1%/10KMaximum: 3 kDesignation Connection Measuring range Measuring accuracy Effect of ambient3-wire/4-wire 2-wiretemperaturePt100 DIN EN 60751(factory-set)Pt1000 DIN EN 60751(factory-set)Sensor lead resistance2-wire/3-wire4-wire-200 - +850°C 0.05% 0.4% 50 ppm/K2-wire/3-wire4-wire-200 - +850°C 0.1% 0.2% 50 ppm/KMaximum 30 per line with three- and four-wire circuitMeasurement current approx. 250 µALead compensationNot required for three- and four-wire circuit. With a 2-wire circuit, lead resistance can becompensated in the software by correcting the process value.Standard signals inputs (optional board)Designation Measuring range Measuring accuracy Effect of ambient temperatureVoltage0(2) - 10 V0-1VInput resistance E > 100 k 0.05%100 ppm/KElectrical currentResistance transmitter0(4) - 20 mA,voltage drop 1.5 VMinimum: 100 Maximum: 4 k 0.05%100 ppm/K+/- 4 100 ppm/K2011-08-11/00541512


JUMO GmbH & Co. KGDelivery address: Mackenrodtstraße 14,36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607E-mail:mail@jumo.netInternet: www.jumo.netJUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow - Essex CM20 2DY, UKPhone: +44 1279 63 55 33Fax: +44 1279 63 52 62E-mail: sales@jumo.co.ukInternet: www.jumo.co.ukJUMO Process Control, Inc.8 Technology BoulevardCanastota, NY 13032, USAPhone: 315-697-JUMO1-800-554-JUMOFax: 315-697-5867E-mail: info@jumo.usInternet: www.jumo.usData Sheet 202552Page 8/19Temperature compensationType of compensation Range 1Linear 0 - 8%/K -10 - 160°CASTM D1125 - 95 (ultra-pure water) 0 - 100°CNatural waters (ISO 7888) 0 - 36°CReference temperatureAdjustable from 15 - 30°C; preset to 25°C (default)1 Note the sensor operating temperature range!Measuring circuit monitoringInputsUnderrange/Short circuitBroken leadoverrangeConductivity Yes Depends on measuring range Depends on measuring rangeTemperature Yes Yes YesVoltageCurrent2 - 10 V2-10V4 - 20 mA0-20mAYesYesYesYesResistance transmitter No No YesYesNoYesNoYesNoYesNoTwo-electrode systemsCell constant[1/cm]0.01Setting range of therelative cell constant1.0 20 - 500%0.2 - 53.0 0.6 - 1510.0 2.0 - 50Resultingusable range [1/cm]0.002 - 0.050.1 0.02 - 0.5Four-electrode systemsCell constant[1/cm]0.5Setting range of therelative cell constant0.1 - 0.7520 - 150%1.0 0.2 - 1.5Resultingusable range [1/cm]Binary inputActivation Floating contact is open: function is not activeFloating contact is closed:function is activeFunctionControllerKey lock, manual mode, HOLD, HOLD inverse, alarm suppression, freeze measured value, level lock,reset partial quantity, reset total quantity, parameter set switchoverController typeController structureLimit comparators, limit controllers, pulse length controllers, pulse frequencycontrollers, modulating controllers, continuous controllersP / PI / PD / PID2011-08-11/00541512


JUMO GmbH & Co. KGDelivery address: Mackenrodtstraße 14,36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607E-mail:mail@jumo.netInternet: www.jumo.netJUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow - Essex CM20 2DY, UKPhone: +44 1279 63 55 33Fax: +44 1279 63 52 62E-mail: sales@jumo.co.ukInternet: www.jumo.co.ukJUMO Process Control, Inc.8 Technology BoulevardCanastota, NY 13032, USAPhone: 315-697-JUMO1-800-554-JUMOFax: 315-697-5867E-mail: info@jumo.usInternet: www.jumo.usData Sheet 202552Page 9/19OutputsRelay (changeover)- Contact rating- Contact service lifeSupply voltage for2-wire transmitterPower supply forinductive proximity switchRelay (changeover)- Contact rating- Contact service lifeRelay SPST (normally open)- Contact rating- Contact service lifeSemiconductor relay- Contact rating- Protective circuitPSU boardPSU boardOptional boardOptional boardOptional boardOptional board5 A at 240 VAC resistive load350,000 operations at nominal load/750,000 operations at 1 AElectrically isolated, non-controlledDC 15.8 - 15.2V; 30 . 50 mADC 12 V; 10 mA8 A at AC 240 V resistive load100,000 operations at nominal load/350,000 operations at 3A3A at 240VAC resistive load350,000 operations at nominal load/900,000 operations at 1A1 A at 240 VVaristorSemiconductor switch (photo MOS) Optional board U 50 V AC/DCI 200 mAVoltage- Output signals- Load resistance- AccuracyElectrical current- Output signals- Load resistance- AccuracyOptional boardOptional board0-10V / 2-10VR load 500 0.5%0-20mA / 4-20mAR load 500 0.5%DisplayTypeElectrical dataSupply voltage (switch-mode PSU)LC graphic display, blue with background lighting, 122 x 32 pixelsAC 110 - 240 V -15/+10%; 48 - 63 Hz orAC/DC 20-30 V; 48 - 63 HzElectrical safety to DIN EN 61010, Part 1overvoltage category II, pollution degree 2Power consumptionMax. 13 VAData backupEEPROMElectrical connectionOn the back via screw terminals,conductor cross-section up to max. 2.5 mm 2Electromagnetic Compatibility (EMC)- Interference emission- Immunity to interferenceDIN EN 61326-1Class Ato industrial requirementsEnclosureEnclosure type Plastic enclosure for panel mounting to DIN IEC 61554Depth behind panelAmbient temperatureStorage temperatureClimatic ratingOperating positionEnclosure protection- In the panel enclosure- In the surface-mounted enclosureWeight (fully fitted)90 mm-5 - +55°C-30 - +70°CRel. humidity 90% annual mean, no condensationHorizontalto DIN EN 60529front IP65, rear IP20IP65approx. 380 g2011-08-11/00541512


JUMO GmbH & Co. KGDelivery address: Mackenrodtstraße 14,36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607E-mail:mail@jumo.netInternet: www.jumo.netJUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow - Essex CM20 2DY, UKPhone: +44 1279 63 55 33Fax: +44 1279 63 52 62E-mail: sales@jumo.co.ukInternet: www.jumo.co.ukJUMO Process Control, Inc.8 Technology BoulevardCanastota, NY 13032, USAPhone: 315-697-JUMO1-800-554-JUMOFax: 315-697-5867E-mail: info@jumo.usInternet: www.jumo.usData Sheet 202552Page 10/19InterfaceModbusInterface typeRS422/RS485ProtocolModbus, Modbus IntegerBaud rate 9600. 19200, 38400Device address 0 - 255Max. number of nodes 32PROFIBUS-DPDevice address 0 - 255Approvals/marks of conformityMark of Testing laboratoryconformityCertificates/certificationnumbersTest basisc UL us Underwriters Laboratories Registered UL 61010-1CAN/CSA-C22.2 No. 61010-1valid forJUMO dTRANS CR 022011-08-11/00541512


12345678910111212346789101112131415L1(L+)N(L+)45689111213151617JUMO GmbH & Co. KGDelivery address: Mackenrodtstraße 14,36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607E-mail:mail@jumo.netInternet: www.jumo.netJUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow - Essex CM20 2DY, UKPhone: +44 1279 63 55 33Fax: +44 1279 63 52 62E-mail: sales@jumo.co.ukInternet: www.jumo.co.ukJUMO Process Control, Inc.8 Technology BoulevardCanastota, NY 13032, USAPhone: 315-697-JUMO1-800-554-JUMOFax: 315-697-5867E-mail: info@jumo.usInternet: www.jumo.usData Sheet 202552Page 11/19Electrical connection(c)(b)(a)(1)(2)(3)Mounting information for conductor cross-sections and ferrulesFerruleConductor crosssectionMinimumferrule lengthMini mum Ma xi mumor strippingWithout ferrule 0.34mm 2 . 2.5mm 2 . 10mm (stripping)Without collar 0.25mm 2.5mm 2 . 10mmWith collar up to 1.5mm² 0.25mm 2 . 1.5mm 2 . 10mmTwin, with collar 0.25mm 2 . 1.5mm 2 . 12mm(1) Row 1 (a) Option 1 (b) Option 2 (c) Option 3(2) Row 2 Main board (conductivity / resistance / temperature / standard signal)(3) Row 3 PSU board (power supply / 2x relays)Optional board (row 1, slot a, b or c)Function Symbol Terminalfor slot (a)Analog inputTemperature sensor in a two-wire circuitPt100 or Pt100024Terminalfor slot (b)68Terminalfor slot (c)1012Temperature sensor in a three-wire circuitPt100 or Pt1000234678101112Resistance transmitter 2ES34AElectrical current +34-Voltage0(2) - 10 VVoltage0-1VTxD-RS485 RxD/TxD+34RxD/TxD--Continuous outputCurrent or voltage +23-Modbus interfaceRS422 RxD+12RxD-34TxD++-+122367878566767567878101112111291010111011910111211122011-08-11/00541512


JUMO GmbH & Co. KGDelivery address: Mackenrodtstraße 14,36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607E-mail:mail@jumo.netInternet: www.jumo.netJUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow - Essex CM20 2DY, UKPhone: +44 1279 63 55 33Fax: +44 1279 63 52 62E-mail: sales@jumo.co.ukInternet: www.jumo.co.ukJUMO Process Control, Inc.8 Technology BoulevardCanastota, NY 13032, USAPhone: 315-697-JUMO1-800-554-JUMOFax: 315-697-5867E-mail: info@jumo.usInternet: www.jumo.usData Sheet 202552Page 12/19Function Symbol Terminalfor slot (a)Profibus interfaceVP(+5V)12RxD/TxD-P(B)3RxD/TxD-N(A) 4DGNDDatalogger interfaceRS485 RxD/TxD+23RxD/TxD-Relay (1x changeover)O K3 12P3Terminalfor slot (b)K4 567567867Terminalfor slot (c)91011121011K5 91011SRelay (2x NO, common pin)K3 12K6 3K5 910K8 11Triac (1 A)K3 23K4 67K5 1011Foto-MOS relay (0.2 A)K3 12K4 56K5 910K6 34K7 78K8 1112Main board (row 2)Function Symbol TerminalStandard signal input for electrical current0(4) - 20 mAStandard signal input for voltage0(2) - 10 V or 10 - 0(2) VTemperature sensor in a two-wire circuitPt100 or Pt1000+-+-3414234Temperature sensor in a three-wire circuitPt100 or Pt1000234Resistance transmitter 4E3S2AFunction Symbol Terminal2011-08-11/00541512


JUMO GmbH & Co. KGDelivery address: Mackenrodtstraße 14,36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607E-mail:mail@jumo.netInternet: www.jumo.netJUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow - Essex CM20 2DY, UKPhone: +44 1279 63 55 33Fax: +44 1279 63 52 62E-mail: sales@jumo.co.ukInternet: www.jumo.co.ukJUMO Process Control, Inc.8 Technology BoulevardCanastota, NY 13032, USAPhone: 315-697-JUMO1-800-554-JUMOFax: 315-697-5867E-mail: info@jumo.usInternet: www.jumo.usData Sheet 202552Page 13/19Conductivity cellConductivity cell (2-electrode system)Terminals 6+7 and 8+9 can be bridged on the instrument;2-wire cable routing up to the head of the conductivitycell.For concentric cells, terminal 6 must be connected withthe outer electrode.Conductivity cell (2-electrode system)Wiring for highest accuracy;4-wire cable routing to the head of the conductivity cell.For concentric cells, terminal 6 must be connected withthe outer electrode.Conductivity cell (4-electrode system)6 - Outer electrode 17 - Inner electrode 18 - Inner electrode 29 - Outer electrode 2Shield connectionConductivity cell67896789678910 GNDBinary inputsBinary input 1 12+14Binary input 2 13+14PSU board (row 3)Function Symbol TerminalPower supply for JUMO dTRANS 02Power supply: AC 110 - 240 V1 L1 (L+)Power supply: AC/DC 20 - 30 V2 N (L-)n.c. 456Supply voltage for external 2-wire transmitter24 V DC (-15 / +20%) 8 L +9 L Relay 1Switching output K1(floating)Relay 2Switching output K2(floating)OPSOPS1112131516172011-08-11/00541512


JUMO GmbH & Co. KGDelivery address: Mackenrodtstraße 14,36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607E-mail:mail@jumo.netInternet: www.jumo.netJUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow - Essex CM20 2DY, UKPhone: +44 1279 63 55 33Fax: +44 1279 63 52 62E-mail: sales@jumo.co.ukInternet: www.jumo.co.ukJUMO Process Control, Inc.8 Technology BoulevardCanastota, NY 13032, USAPhone: 315-697-JUMO1-800-554-JUMOFax: 315-697-5867E-mail: info@jumo.usInternet: www.jumo.usData Sheet 202552Page 14/19DimensionsAABA PC interface socketB Panel cutout to DIN IEC 61554: 2002-08Close mountingMinimum spacing of panel cutouts Horizontal VerticalWithout setup connector: 30mm 11mmWith setup connector (see arrow): 65mm 11mmApplication examplesConductivity measurement (temperature compensated)(1) JUMO dTRANS CR 02(2) Conductivity cell(2)(1)2011-08-11/00541512


JUMO GmbH & Co. KGDelivery address: Mackenrodtstraße 14,36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607E-mail:mail@jumo.netInternet: www.jumo.netJUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow - Essex CM20 2DY, UKPhone: +44 1279 63 55 33Fax: +44 1279 63 52 62E-mail: sales@jumo.co.ukInternet: www.jumo.co.ukJUMO Process Control, Inc.8 Technology BoulevardCanastota, NY 13032, USAPhone: 315-697-JUMO1-800-554-JUMOFax: 315-697-5867E-mail: info@jumo.usInternet: www.jumo.usData Sheet 202552Page 15/19Redox measurement and conductivity measurement (temperature compensated)(1) JUMO dTRANS CR 02(2) Redox combination electrode(3) 2-wire transmitter,type 202701(4) Conductivity cell(1)(3) (4)(2)Conductivity measurement (temperature compensated) and level or liquid levelmeasurement 1 (2)(1)(1) JUMO dTRANS CR 02(2) Conductivity cell(3) Level measurement probeType JUMO dTRANS p90 or type404390 or type 404391(3)2011-08-11/00541512


JUMO GmbH & Co. KGDelivery address: Mackenrodtstraße 14,36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607E-mail:mail@jumo.netInternet: www.jumo.netJUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow - Essex CM20 2DY, UKPhone: +44 1279 63 55 33Fax: +44 1279 63 52 62E-mail: sales@jumo.co.ukInternet: www.jumo.co.ukJUMO Process Control, Inc.8 Technology BoulevardCanastota, NY 13032, USAPhone: 315-697-JUMO1-800-554-JUMOFax: 315-697-5867E-mail: info@jumo.usInternet: www.jumo.usData Sheet 202552Page 16/19Conductivity measurement and flow-rate measurement(1) JUMO dTRANS CR 02(2) Conductivity cell(3) MID flow rate transmitter,type 406010(2)(1)(3)2011-08-11/00541512


JUMO GmbH & Co. KGDelivery address: Mackenrodtstraße 14,36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607E-mail:mail@jumo.netInternet: www.jumo.netJUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow - Essex CM20 2DY, UKPhone: +44 1279 63 55 33Fax: +44 1279 63 52 62E-mail: sales@jumo.co.ukInternet: www.jumo.co.ukJUMO Process Control, Inc.8 Technology BoulevardCanastota, NY 13032, USAPhone: 315-697-JUMO1-800-554-JUMOFax: 315-697-5867E-mail: info@jumo.usInternet: www.jumo.usData Sheet 202552Page 17/19Order details: JUMO dTRANS CR 02(1) Basic type202552 JUMO dTRANS CR 02Transmitter/controller(2) Basic type extension01 In the panel enclosure05 In the surface-mounted enclosure(3) Version8 Standard with factory setting9 Programming to customer specification(4) Operating language 101 German02 English03 French04 Dutch05 Russian06 Italian07 Hungarian08 Czech09 Swedish10 Polish13 Portuguese14 Spanish16 Rumanian(5) Optional slot 10 Not used1 Analog input 2 (universal)2 Relay (1x changeover)3 Relay (2x normally open)4 Analog output5 Two MosFET semiconductor switch6 Semiconductor relay 1 A8 Supply voltage output 12 V DC (e.g. for inductive proximityswitch)(6) Optional slot 20 Not used1 Analog input 2 (universal)2 Relay (1x changeover)4 Analog output5 Two MosFET semiconductor switch6 Semiconductor relay 1 A8 Supply voltage output 12 V DC (e.g. for inductive proximityswitch)1 All languages are available on the instrument and can be changed by the customer at any time. Factory default setting to a language (otherthan "German") is available for a charge.2011-08-11/00541512


JUMO GmbH & Co. KGDelivery address: Mackenrodtstraße 14,36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607E-mail:mail@jumo.netInternet: www.jumo.netJUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow - Essex CM20 2DY, UKPhone: +44 1279 63 55 33Fax: +44 1279 63 52 62E-mail: sales@jumo.co.ukInternet: www.jumo.co.ukJUMO Process Control, Inc.8 Technology BoulevardCanastota, NY 13032, USAPhone: 315-697-JUMO1-800-554-JUMOFax: 315-697-5867E-mail: info@jumo.usInternet: www.jumo.usData Sheet 202552Page 18/19(7) Optional slot 300 Not used01 Analog input 2 (universal)02 Relay (1x changeover)03 Relay (2x normally open)04 Analog output05 Two MosFET semiconductor switch06 Semiconductor relay 1 A08 Supply voltage output 12 V DC (e.g. for inductive proximityswitch)10 Interface - RS422/48511 Datalogger with interface RS485 212 Profibus DP interface(8) Power supply23 110 - 230 V AC, +10% / -15%, 48 - 63 Hz25 20 - 30 V AC/DC, 48 - 63 Hz(9) Extra codes 3000 None2 The only way to read data is with the PC setup software!3 List extra codes in sequence, separated by commas.(1) (2) (3) (4) (5) (6) (7) (8) (9)Order code / - - - - - - / , ... 3Sample order 202552 / 01 - 8 - 01 - 2 - 2 - 04 - 23 / 000Stock versions(delivery 3 working days after receipt of order)Order codeSalesNo.202552/01-8-01-4-0-00-23/000 20/00550843Accessories(delivery 10 working days after receipt of order)ItemSalesNo.Holder for C rail; PG 709710 70/00375749Dummy cover 96mm x 48mm; PG 709710 70/00069680Pipe mounting set; PG 209791 20/00398162Weather protection roof complete for basic type extension 05; PG 209791 20/00401174PC setup software PG 202599 20/00560380PC interface cable including USB/TTL converter and two adapters (USB connecting cable) PG 709720 70/004563522011-08-11/00541512


JUMO GmbH & Co. KGDelivery address: Mackenrodtstraße 14,36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607E-mail:mail@jumo.netInternet: www.jumo.netJUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow - Essex CM20 2DY, UKPhone: +44 1279 63 55 33Fax: +44 1279 63 52 62E-mail: sales@jumo.co.ukInternet: www.jumo.co.ukJUMO Process Control, Inc.8 Technology BoulevardCanastota, NY 13032, USAPhone: 315-697-JUMO1-800-554-JUMOFax: 315-697-5867E-mail: info@jumo.usInternet: www.jumo.usData Sheet 202552Page 19/19Optional board Code SalesNo.Analog input (universal) 1 70/00442785Relay (1 x changeover) 2 70/00442786Relay (2 x NO) 3 70/00442787Analog output 4 70/00442788Two MosFET semiconductor switch 5 20/00566677Semiconductor relay 1 A 6 70/00442790Supply voltage output +/- 5 V DC (e.g. for ISFET) 7 20/00566681Supply voltage output 12 V DC (e.g. for inductive proximity switch) 8 20/00566682Interface - RS422/485 10 70/00442782Datalogger with RS485 interface 11 20/00566678Profibus-DP interface 12 20/005666792011-08-11/00541512

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!