Self-Inspection Checklist for Apartment Buildings

Self-Inspection Checklist for Apartment Buildings

Self-Inspection Checklist for Apartment Buildings

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

FIRE PROTECTION SYSTEMS If your apartment building is more than three stories in height or has more than16 dwelling units or sleeping units, does it have a fire alarm system? F-907.3.1.7 Yes No N/AMonitored: ____ Not monitored: ____ Monitored by: ____________________ Has the automatic sprinkler system been inspected and tested by a sprinklercontractor within the past year? F-903.5 Yes No N/ADate of last service: __________________ (Copy of the report attached). Are caps installed on fire department connections? F-912.3.1 and F-912.6 Yes No N/A Has the fire alarm system been inspected and serviced by a fire alarmcontractor within the past year? F-907.20 Yes No N/ADate of last service: __________________ (Copy of the report attached). Are all fire alarm pull stations unobstructed and visible? F-907.20.1 Yes No N/A Have all portable fire extinguishers been serviced within the past year? F-906.2 Yes No N/ADate of last service: __________________ Are fire extinguishers installed where required and located in conspicuous locationswhere they will be readily accessible and immediately available <strong>for</strong> use? F-906.5 Yes No N/A Are smoke detectors a.c. powered having battery backup? F-907.3.2.3 Yes No N/A Are smoke detectors tested routinely when new tenants move in? F-907.20.2 Yes No N/ATesting required monthly NFPA72-10.4.4EMERGENCY GUIDE Has an fire emergency guide been provided describing the location, function, anduse of fire alarm systems, smoke alarms, and portable fire extinguishers? F-408.9.1 Yes No N/A Has an emergency evacuation plan <strong>for</strong> each dwelling unit been provided? F-408.9.1 Yes No N/A Has a copy of the emergency guide been provided to each tenant? F-408.9.3 Yes No N/AHOUSEKEEPING Are flammable and combustible liquids kept to a minimum and maintained in anorderly manner? F-3404.3.3.5.3 Yes No N/A Are flammable and combustible liquids kept in metal containers? F-3404.3.6.1 Yes No N/A Do flammable and combustible liquid storage tanks and storage tank areashave the required labeling and signage? F-3404.2.3 Yes No N/A Is storage at least 2 feet below the ceiling in non-sprinklered buildings? F-315.2.1 Yes No N/A Is storage at least 18 inches below sprinkler heads? F-315.2.1 Yes No N/A Is there storage near heat sources (furnaces, hot water heaters)? F-315.2 Yes No N/A Is the laundry equipment and vent piping free of dust and lint? MC22-405.3 Yes No N/A Are fire-rated construction barriers intact with no holes or missing sections? Yes No N/A(This is of primary importance in ceilings between parking levels and dwellingunits.) F-703.1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!