<strong>EWP</strong> WALL PANELPANEL CLIP AT PANELJOINT W/ (2) SELFDRILLING SCREWS1/8 X 3/4 FOAM TAPE(HW0315) CONTINUOUSBASE ANGLE(NOT BY <strong>IPS</strong>)CONCRETESILLTRIM3/8" DIA BEAD OF BUTYLSEALANT (HW0301) CONTINUOUSWALL BASE WITH RECESS<strong>EWP</strong>-111-3-03


<strong>EWP</strong>WALL PANEL1/8 X 3/4 FOAM TAPE(HW0315) CONTINUOUSPANEL CLIP AT PANELJOINT W/ (2) SELFDRILLING SCREWSBASE ANGLE(NOT BY <strong>IPS</strong>)CONCRETESILL TRIM3 1/2" X 1 1/4" X 14 GA. GALV. ANGLEATTACH TRIM AND ANGLE WITH"T" RIVETS (HW0211) AT 12" O.C.3/8" DIA BEAD OF BUTYLSEALANT (HW0301) CONTINUOUSWALLBASE WITHOUT RECESS<strong>EWP</strong>-211-3-03


GIRT<strong>EWP</strong>WALL PANELPANEL CLIP AT PANELJOINT W/ (2) SELFDRILLING SCREWSINTERIOR FACEEXTERIORFACEGIRT DETAIL W/ COLD FORMEDZEE<strong>EWP</strong>-311-3-03


STRUCTURALSUPPORT<strong>EWP</strong>WALL PANELPANEL CLIP AT PANELJOINT W/ (2) SELFDRILLINGSCREWSINTERIOR FACEEXTERIOR FACEGIRTDETAIL W/ HOT ROLLED MEMBER<strong>EWP</strong>-411-3-03


<strong>EWP</strong> WALL PANELSEE PLANINSIDE CORNER TRIMATTACH W/ 1/8" RIVETS(HW0056) AT 12" O.C.3/32 X 3/8 TAPE SEALANT(HW0001) CONTINUOUS1/4-14 X 7/8" S.D. SCREWS(SC0540) AT 12" O.C. BETWEENSUPPORT SCREWS#14 SCREWSAT EACH FRAMING MEMBER(SELF TAPPING)OUTSIDE CORNER TRIMSEE PLAN<strong>EWP</strong>WALL PANEL<strong>EWP</strong>-5OUTSIDE CORNER11-3-03


SEE PLANOUTSIDE CORNER TRIMATTACH W/ 1/8" RIVETS(HW0056) AT 12" O.C.<strong>EWP</strong> WALL PANELSEE PLAN3/32 X 3/8 TAPE SEALANT(HW0001) CONTINUOUS1/4-14 X 7/8" S.D. SCREWS(SC0540) AT 12" O.C. BETWEENSUPPORT SCREWS#14 SCREWSAT EACH FRAMING MEMBER (SELF TAPPING)INSIDE CORNERTRIM<strong>EWP</strong> WALL PANELINSIDECORNER<strong>EWP</strong>-611-3-03


``C'' SECTION CLIP (HW0356) AT 24" O.C.ATTACH W/ 5/16" X 1 3/8" FAB-LOKFASTENERS (HW0360)CHANNEL JAMB(NOT BY <strong>IPS</strong>)WALK DOOR FRAME(NOT BY<strong>IPS</strong>)1/8" X 3/4" FOAM TAPE(HW0315) CONTINUOUS<strong>EWP</strong> WALLPANELJAMBTRIM1/4-14 X 7/8" SELF-DRILL SCREW(SC0540) AT 12" 0.C.JAMB DETAIL AT WALK DOOR<strong>EWP</strong>-911-3-03


<strong>EWP</strong> WALL PANELPANEL CLIP AT PANELJOINT W/ (2) SELFDRILLING SCREWS1/8" X 3/4" FOAM TAPE(HW0315) CONTINUOUSSILICONE SEALANT(HW0313) (CONT.)CHANNEL HEADER(NOT BY <strong>IPS</strong>)HEAD TRIM1/4-14 X 7/8" SELF DRILLINGSCREW (SC0540) AT 12" O.C.WALK DOOR FRAME(NOT BY <strong>IPS</strong>)2 3/4" X 1 1/4" X 14 GA. GALV. ANGLEATTACHTRIM AND ANGLE WITH"T" RIVETS (HW0211) AT 12" O.C.HEAD DETAIL AT WALK DOOR<strong>EWP</strong>-1011-3-03


<strong>EWP</strong> WALL PANELPANEL CLIP AT PANELJOINT W/ (2) SELFDRILLING SCREWS1/8" X 3/4" FOAM TAPE(HW0315) CONTINUOUSSILICONE SEALANT(HW0313) (CONT.)CHANNEL HEADER(NOT BY <strong>IPS</strong>)HEADTRIM1/4-14 X 7/8" SELF DRILLINGSCREW (SC0540) AT 12" O.C.2 3/4" X 1 1/4" X 14 GA. GALV. ANGLEATTACH TRIM AND ANGLE WITH"T" RIVETS (HW0211) AT 12" O.C.LOUVER(NOT BY<strong>IPS</strong>)HEAD DETAIL ATLOUVER<strong>EWP</strong>-1111-3-03


CHANNEL JAMB(NOT BY <strong>IPS</strong>)LOUVER(NOT BY <strong>IPS</strong>)``C'' SECTION CLIP (HW0356) AT 24" O.C.ATTACH W/ 5/16" X 1 3/8" FAB-LOKFASTENERS (HW0360)1/8" X 3/4" FOAM TAPE(HW0315) CONTINUOUS<strong>EWP</strong> WALLPANELJAMB TRIM1/4-14 X 7/8" SELF-DRILL SCREW(SC0540) AT 12" 0.C.JAMB DETAIL AT LOUVER<strong>EWP</strong>-1211-3-03


SILICONE SEALANT(HW0313) CONT.SILL TRIMOUTSIDE CLOSURECS0160LOUVER(NOT BY <strong>IPS</strong>)CHANNEL(NOT BY <strong>IPS</strong>)1/4-14 X 7/8" SELF DRILLSCREW AT 12" O.C. (SC0540)1/8" X 3/4" FOAM TAPE(HW0315) CONTINUOUS<strong>EWP</strong>WALL PANEL``C'' SECTION CLIP (HW0356) AT24" O.C. ATTACH W/ FAB-LOKFASTENER (HW0360)SILL DETAILAT LOUVER<strong>EWP</strong>-1311-3-03


<strong>EWP</strong> WALL PANELPANEL CLIP AT PANELJOINT W/ (2) SELFDRILLING SCREWS1/8" X 3/4" FOAM TAPE(HW0315) CONTINUOUSSILICONE SEALANT(HW0313) (CONT.)CHANNEL HEADER(NOTBY <strong>IPS</strong>)HEAD TRIM1/4-14 X 7/8" SELF DRILLINGSCREW (SC0540) AT 12" O.C.WINDOW(NOT BY <strong>IPS</strong>)2 3/4" X 1 1/4" X 14 GA. GALV. ANGLEATTACH TRIM AND ANGLE WITH"T" RIVETS (HW0211) AT 12" O.C.HEADDETAIL AT WINDOW<strong>EWP</strong>-1411-3-03


CHANNEL JAMB(NOT BY <strong>IPS</strong>)WINDOW(NOTBY <strong>IPS</strong>)``C'' SECTION CLIP (HW0356) AT 24" O.C.ATTACH W/ 5/16" X 1 3/8" FAB-LOKFASTENERS (HW0360)1/8" X 3/4" FOAM TAPE(HW0315) CONTINUOUS<strong>EWP</strong> WALLPANELJAMB TRIM1/4-14 X 7/8" SELF-DRILL SCREW(SC0540) AT 12" 0.C.JAMB DETAILAT WINDOW<strong>EWP</strong>-1511-3-03


SILICONE SEALANT(HW0313) CONT.SILL TRIMWINDOW(NOT BY <strong>IPS</strong>)OUTSIDE CLOSURECS0160CHANNEL(NOT BY <strong>IPS</strong>)1/4-14 X 7/8" SELF DRILLSCREW AT 12" O.C. (SC0540)1/8" X 3/4" FOAM TAPE(HW0315) CONTINUOUS<strong>EWP</strong>WALL PANEL``C'' SECTION CLIP (HW0356) AT24" O.C. ATTACH W/ FAB-LOKFASTENER (HW0360)SILL DETAIL ATWINDOW<strong>EWP</strong>-1611-3-03


<strong>EWP</strong>WALLPANELPANEL CLIP AT PANELJOINTDRILLINGW/ (2) SELFSCREWSSILICONE SEALANT(HW0313) CONT.2 3/4" X 1 1/4" X 14 GA. GALV. ANGLEATTACH HEAD TRIM AND ANGLE W/"T" RIVETS (HW0211) AT 12" O.C.1/8" X 3/4" FOAM TAPEHW0315 CONTINUOUSGIRT(NOT BY <strong>IPS</strong>)STACK JOINT TRIM1/4-14 X 7/8" S.D. SCREWS(SC0540) AT 12" O.C.OUTSIDE CLOSURE(CS 0160 )PANEL CLIPJOINTDRILLING4" X 2" X 14 GA. ANGLEATTACH TO GIRT W/ 1/4-14 X 1"S.D. SCREW (SC0401) AT 12" O.C.1/8" X 3/4" FOAM TAPEHW0315 CONTINUOUSAT PANELW/ (2) SELFSCREWSDETAIL AT WALL SPLICE WITH COLDFORMED MEMBER<strong>EWP</strong>-1711-3-03


<strong>EWP</strong>WALLPANELPANEL CLIP AT PANELJOINT W/ (2) SELFDRILLING SCREWSSILICONE SEALANTHW03132 3/4" X 1 1/4" X 14 GA. GALV. ANGLEATTACH HEAD TRIM AND ANGLE W/"T" RIVETS (HW0211) AT 12" O.C.1/8" X 3/4" FOAM TAPEHW0315 CONTINUOUSSTRUCTURAL(NOT BY <strong>IPS</strong>)GIRTSTACK JOINT TRIM1/4-14 X 7/8" S.D. SCREWS(SC0540) AT 12" O.C.OUTSIDE CLOSURE(CS 0160 )4" X 2" X 14 GA. ANGLEATTACH TO GIRT W/ 1/4-14 X 1"S.D. SCREW (SC0401) AT 12" O.C.1/8" X 3/4" FOAM TAPEHW0315 CONTINUOUSPANEL CLIP AT PANELJOINT W/ (2) SELFDRILLING SCREWSDETAIL AT WALL SPLICE WITH HOT ROLLED MEMBER<strong>EWP</strong>-1811-3-03


INTERIOR FACEEXTERIORFACE36" NOMINALJOINTSEALANT<strong>EWP</strong> WALL PANELFASTENER PLACEMENT DETAILPANEL CLIPINTERIOR FACENOTE:FIELD APPLIED JOINT SEALANTHW0301, APPLY MINIMUM 3/8"EXTERIORFACESEE DETAIL"A"BEAD. ONE TUBE = APPROX.15 L.F. OF PANEL JOINTJOINTSEALANT APPLICATIONDETAIL "A"<strong>EWP</strong>-1911-3-03