IPS-EWP Detail - Ceco Building Systems
IPS-EWP Detail - Ceco Building Systems
IPS-EWP Detail - Ceco Building Systems
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>EWP</strong>WALLPANELPANEL CLIP AT PANELJOINTDRILLINGW/ (2) SELFSCREWSSILICONE SEALANT(HW0313) CONT.2 3/4" X 1 1/4" X 14 GA. GALV. ANGLEATTACH HEAD TRIM AND ANGLE W/"T" RIVETS (HW0211) AT 12" O.C.1/8" X 3/4" FOAM TAPEHW0315 CONTINUOUSGIRT(NOT BY <strong>IPS</strong>)STACK JOINT TRIM1/4-14 X 7/8" S.D. SCREWS(SC0540) AT 12" O.C.OUTSIDE CLOSURE(CS 0160 )PANEL CLIPJOINTDRILLING4" X 2" X 14 GA. ANGLEATTACH TO GIRT W/ 1/4-14 X 1"S.D. SCREW (SC0401) AT 12" O.C.1/8" X 3/4" FOAM TAPEHW0315 CONTINUOUSAT PANELW/ (2) SELFSCREWSDETAIL AT WALL SPLICE WITH COLDFORMED MEMBER<strong>EWP</strong>-1711-3-03