11.07.2015 Views

Parker Lucifer - Coeva

Parker Lucifer - Coeva

Parker Lucifer - Coeva

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

8700/GBExplosion-proof electrical parts3.5.2 Electrical parts 492200 or VZ13, 492210 or VZ269 / 10Application: Control of solenoid valves in dangerous areas where explosionproofprotection EEx me II T5 to T6 is required.Benefits: Rotatable 360°, fibreglass-reinforced plastic housing. Solenoid coiland booster electronic are completely encapsulated into the coil housing byepoxy resin for shock and corrosion protection.Small size for ease of mounting in confined space.All <strong>Lucifer</strong> valves suitable for CPR/Offshore application can be fitted with theseelectrical parts (except type U033X).These electrical parts conform to the IEC/CENELEC safety standards andcomply with European explosive atmosphere directive 94/9/EC «ATEX».9 10Reference 492200 or VZ13 492210 or VZ26ApprovalType of protectionLCIE 02 ATEX 6023 XGas II 2 G - EEx me II T5 II 2 G - EEx me II T6 II 2 G - EEx me II T5 II 2 G - EEx me II T6Dust II 2 D -95°C II 2 D -80°C II 2 D -95°C II 2 D -80°CDegree of protection IP66 IP66Ambient temperature -40°C to +75°C -40°C to +40°C -40°C to +75°C -40°C to +40°CThe application is limited also by the temperature range of the valveClass of insulation F (155°C) F (155°C)Electrical connectionPower consumption DC 1 bis 1.8 W, depending on cable length 1 bis 1.8 W, depending on cable lengthInrush current (attraction)min. required for holdingVoltage DCProvided by booster circuit during ~50 ms as soon as the Zener voltage of 21.6 V is reachedI mini = 60 mA (I nominal = 75 mA)U nominal = 24 VDC, Umini = 21.6 VDCResistance/additional resistance 23 Ω + (R = 270 Ω)Inductance0 mHCapacitance 0 µFResponse timeVoltage / Voltage toleranceScrew terminals within terminal box. Cable connection through a cable gland M20X1.5Additional earth connection on external screw terminal2 - 4 ssee voltage code table / tolerance ± 10% of the nominal voltageSolenoid duty Continuous duty solenoid (ED 100%)3Weight: 500 g.Indications:VZ13 = Booster for CPR valvesVZ26 = Booster for Offshore valvesThese electrical parts needan external fuse of I = 100 mAdelivered only with 49220029 <strong>Parker</strong> <strong>Lucifer</strong> SA357 Fluid <strong>Parker</strong> Control <strong>Lucifer</strong> Division SA EuropeCH-1227 Fluid Control Carouge-GenèveDivision EuropeCH-1227 Carouge-Genève

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!