11.07.2015 Views

Parker Lucifer - Coeva

Parker Lucifer - Coeva

Parker Lucifer - Coeva

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

8700/GB3.4.2 Electrical parts 483270 or HZ19 and 483270.02 or HZ219Application: Control of solenoid valves in dangerous areas where explosionproofprotection EEx d IIC T4 to T6 is required.Benefits: Rotatable 360°, housing made of cast iron with internal connectionchamber: Cover made of aluminium alloy fixed with 4 screws. Theelectromagnetic control pilot is composed of three main elements: housing,coil and plunger tube including housing plate.Small size for ease of mounting in confined space.All <strong>Lucifer</strong> valves with suffix ‘‘1D’’ and suited for CPR/Offshore application canbe fitted with these electrical partsThese electrical parts conform to the IEC/CENELEC safety standards andcomply with European explosive atmosphere directive 94/9/EC «ATEX».Reference 483270 or HZ19 (M20 x 1.5) 483270.02 or HZ21 (1/2 NPT)ApprovalType of protectionLCIE 02 ATEX 6008 XGas II 2 G - EEx d IIC T4 II 2 G - EEx d IIC T5 II 2 G - EEx d IIC T6Dust II 2 D - 130°C II 2 D - 95°C II 2 D - 80°CDegree of protection IP65 with appropriate cable glandAmbient temperature -40 to +80°C -40 to +75°C -40 to +60°CThe application is limited also by the temperature range of the valveClass of insulation F (155°C) F (155°C)Electrical connectionElect.PowerDCACPn (hot)P (cold) 20°CPn (holding)Attraction coldVoltage / Voltage toleranceThe electrical connection is made within the housing connection chamber on an accessiblescrew terminal. The cable entry to the connecting chamber is made through 1/2"NPT or M20 x 1.5 thread suitable for fitting an approved EEx d IIC cable gland.8 W9 W8 W9 Wsee voltage code table / tolerance -10/ +10% of the nominal voltageSolenoid duty Continuous duty solenoid (ED 100%)Weight: 1100 g (with coil)Plunger tubeThe plunger tube is welded to the stainless steel plate and is thusintegrated to the housing which is screwed on the valve body.This electrical part is supplied only as complete unit mounted on a valve,as the ‘‘EEx d’’ protection depends on minimum gap between plungertube, plate and housing.M20 x 1.5 (1/2 - NPT)32 <strong>Parker</strong> <strong>Lucifer</strong> SA360 Fluid <strong>Parker</strong> Control <strong>Lucifer</strong> Division SA EuropeCH-1227 Fluid Control Carouge-GenèveDivision EuropeCH-1227 Carouge-Genève

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!