8700/GBExplosion-proof electrical parts3.7.7 Electrical parts 492965.01 or VZ91 with ‘‘Booster’’.9Application: Control of solenoid valves in dangerous areas where anexplosion-proof protection EEx ia IIC T6 is required.Benefits: Rotatable 360° housing, polyamid with fibreglass housing andcover. Coil, electronic circuits and other elements required for intrinsic safetyare completely encapsulated in the housing with epoxy material for shock andcorrosion protection.Small size for ease of mounting in confined space.All <strong>Lucifer</strong> valves suitable for CPR/Offshore application can be fitted with theseelectrical parts (except type U033X).These electrical parts conform to the IEC/CENELEC safety standards andcomply with European explosive atmosphere directive 94/9/EC «ATEX».PowerReferenceApprovalType of protectionDegree of protectionAmbiant temperatureElectrical connectionDCMinimumMaximumGasMaximum supply voltageLine check492965.01 or VZ91 - stainless steel fixation492965.02 or VZ92 - plastic fixationLCIE 02 ATEX 6066 XII 1 G - EEx ia IIC T6Dust II 1 D - 80°CIP66-40°C to +65°CThe application is limited also by the temperature range of the valve28 VDC – 110 mA0.3 W (with 13 VDC)2.3 W (with 24 VDC)Depending on applied voltage, IS barrier type and resistance of connected cable4 mA or 5 VDC maxCoil resistance at 20°C85 ΩImpedance275 Ω (with 13 VDC) – 260 Ω (with 24 VDC)Apparent inductance0 mHApparent capacitance 0 µFResponse timeCable connection through a plastic cable gland M20 x 1.5 allowing use of cablediameter from 6 to 12 mm. Additional earth connection possible with external screw terminal2 – 4 sSolenoid durty Continuous duty solenoid (ED 100%)3Weight: 500 g.ImportantThe intrinsically safe supply circuit shouldhave enough capacity under all environmentalconditions to assure a minimum operatingcurrent of 20 mA through the coil.For the barriers compatibility see thecorresponding table in pages 42, 43 and 44.41 <strong>Parker</strong> <strong>Lucifer</strong> SA369 Fluid <strong>Parker</strong> Control <strong>Lucifer</strong> Division SA EuropeCH-1227 Fluid Control Carouge-GenèveDivision EuropeCH-1227 Carouge-Genève

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!