PRODUCT CATALOGUEpressure switch


PressureAT THEHIGHEST LEVEL„Successful medium-sizedcompanies are not successfulbecause they are active in manyareas, but rather because theyconcentrate on one area and do itbetter than anyone else“This is our philosophy. That´s why BDSENSORS hasconcentrated on electronic pressure measurementtechnology from the beginning.With our unremitting product and and quality strategywe have been successful in becoming a majorplayer on the world market for electronic pressuresensing devices within a few years.


With 260 employees at 4 locations in Germany, the CzechRepublic, Russia and China <strong>BD|SENSORS</strong> has solutionsfrom 0.1 mbar to 6000 bar:> > pressure sensors, pressure transducerspressure transmitters> > electronic pressure switches> > pressure measuring devices with display andswitching outputs> > hydrostatic level probesINDEXpressure switchwith display 5-59INDUSTRY 5-53OEM 54-59pressure switchwithout display 60-65Two pressure transmitters and a submersible probe, basedon a stainless steel silicon sensor were the beginning.Today the range extends to more than 70 standard products,from economical OEM devices to high-end productswith HART ® communication or field bus interface.4 ARGUMENTS 66In addition we have developed hundreds of customerspecificapplications, underlining the competence and flexibilityof <strong>BD|SENSORS</strong>. The excellent price/performanceratio of our products is proof of the fact that we are able tomeet the toughest demand: Being a problem-solver for ourcustomers.For large production batches as well as for small productionnumbers, no matter for what medium or externalfactors, with almost any mechanical or electrical connection- we solve your problemflexibly, quickly and cost-efficiently.www.bdsensors.com


4matrixdisplayhousingcontactspressure portstainless steel ballhousingplasticaccuracy (FSO) 11 / 21 / 2 / 4nominal pressure [bar]inch and NPT thraedinch thread flushdairy pipeclampcertificatespagewith displayDS 400 • 0.35 % • 0 … 100 up to 0 … 600 • EX 5-9DS 401 • 0.5 % • 0 … 0.4 up to 0 … 600 • EX 10-14DS 200 • 0.35 % • 0 … 0.1 up to 0 … 600 • EX 15-19DS 201 • 0.5 % • 0 … 0.4 up to 0 … 600 • EX 20-24DS 202 • 0.5 % • 0 … 6 up to 0 … 600 • EX 25-29DS 210 • 0.35 % • 0 … 0.01 up to 0 … 1 • EX 30-34DS 214 • 0.5 % • 0 … 600 up to 0 … 2200 • EX 35-38DS 400P • 0.35 % • 0 … 0.1 up to 0 … 40 • • • EX, 3A 39-43DS 200P • 0.35 % • 0 … 60 up to 0 … 400 • • • EX, 3A 44-48DS 201P • 0.5 % • 0 … 0.1 up to 0 … 40 • EX 49-53DS 217 • 0.5 % • 0 … 6 up to 0 … 600 • 54-56DS 230 • 1.5 % • 0 … 2 up to 0 … 400 • 57-59without displayDS 4 2 % • 0 … 1 up to 0 … 10 • 60-62DS 6 1 % • 0 … 2 up to 0 … 400 • 63-651according to IEC 60770www.bdsensors.com


BD SENSORS GmbHpressure switch with display5DS 400Intelligent ElectronicPressure SwitchStainless SteelStainless Steel Sensoraccuracy according to IEC 60770:standard: 0.35 % FSOoption: 0.25 % FSONominal pressurefrom 0 ... 100 mbar up to 0 ... 600 barContacts1 or 2 independent PNP contacts,freely configurableAnalogue output2-wire: 4 ... 20 mA3-wire: 4 … 20 mA / 0 … 10 Vothers on requestSpecial characteristicsThe electronic pressure switch DS 400 is thesuccessful combination of►►intelligent pressure switchdigital displayand has been specially designed for numerousapplications in various industrial sectors.As standard the DS 400 offers a PNP contactand a display module, which is mounted rotablein the ball housing. Additional optional versionslike e.g. an intrinsically safe version, a secondcontact and an analogue output complete theprofile.Preferred areas of use are►►indication of measured values on a4-digit LED displayrotatable and configurable displaymodulePlant and Machine EngineeringHeating and Air ConditioningOptional versions►IS-versionEx ia = intrinsically safe for gasesEnvironmental Engineering(water – sewage – recycling)►►pressure sensor weldedcustomer specific versionswww.bdsensors.com


6DS 400Technical DataDS 400Electronic Pressure SwitchTechnical DataInput pressure rangeNominal pressuregauge / abs.[bar] -1 … 0 0.10 0.16 0.25 0.40 0.60 1 1.6 2.5 4 6Overpressure [bar] 5 0.5 1 1 2 5 5 10 10 20 40Burst pressure [bar] 7.5 1.5 1.5 1.5 3 7.5 7.5 15 15 25 50Nominal pressuregauge / abs.[bar] 10 16 25 40 60 100 160 250 400 600Overpressure [bar] 40 80 80 105 210 210 600 1000 1000 1000Burst pressure [bar] 50 120 120 210 420 420 1000 1250 1250 1250Vacuum resistance P N ≥ 1 bar: unlimited vacuum resistance P N < 1 bar: on requestContact 1Number, type standard: 1 PNP contact option: 2 independent PNP contactsMax. switching current 4 ... 20 mA / 2- and 3-wire: contact rating 125 mA, short-circuit resistant; V switch = V S − 2V0 ... 10 V / 3-wire: contact rating 500 mA, short-circuit resistantAccuracy of contacts 2≤ ± 0.25 % FSORepeatability≤ ± 0.1 % FSOSwitching frequency 2-wire: max. 10 Hz / 3-wire: 50 HzSwitching cycles > 100 x 10 6Delay time0 ... 100 sec1 with IS-protection max. 1 contact possibleAnalogue output (optionally) / Supply2-wire current signal4 ... 20 mA / V S = 13 ... 36 V DCpermissible load: R max = [(V S – V S min) / 0.02 A] Ωresponse time: < 10 msec2-wire current signal withIS-protection4 ... 20 mA / V S = 13 ... 28 V DCpermissible load: R max = [(V S – V S min) / 0.02 A] Ωresponse time: < 10 msec3-wire current signal 4 ... 20 mA / V S = 24 V DC ± 10 % adjustable (turn-down of span 1:5) 3permissible load: R max = 500 Ωresponse time: < 30 msec3-wire voltage signal 0 … 10 V / V S = 24 V DC ± 10 % adjustable (turn-down of span 1:5) 3permissible load: R min = 10 kΩresponse time: < 30 msecWithout analogue outputV S = 15 ... 36 V DCAccuracy 2standard: nominal pressure < 0,4 bar: ≤ ± 0,5 % FSOnominal pressure ≥ 0,4 bar: ≤ ± 0,35 % FSOoption: nominal pressure ≥ 0,4 bar: ≤ ± 0,25 % FSO2 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)3 with turn-down of span the analogue signal is adjusted automatically to the new measuring rangeThermal effects (Offset and Span)Nominal pressure P N [bar] -1 … 0 < 0.40 ≥ 0.40Tolerance band [% FSO] ≤ ± 0.75 ≤ ± 1 ≤ ± 0.75in compensated range [°C] -20 ... 85 0 ... 70 -20 … 85Permissible temperaturesPermissible temperatures medium: -40 ... 125 °C electronics / environment: -40 ... 85 °C storage:-40 ... 100 °CElectrical protectionShort-circuit protectionpermanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 61326Mechanical stabilityVibration 10 g RMS (25 ... 2000 Hz) according to DIN EN 60068-2-6Shock 500 g / 1 msec according to DIN EN 60068-2-27MaterialsPressure portstainless steel 1.4404 (316L)Housingstainless steel 1.4404 (316L)Viewing glasslaminated safety glassSeals (media wetted) standard: FKMoption: NBR; welded version 4 on request others on requestDiaphragm stainless steel 1.4435 (316 L)Media wetted partspressure port, seals, diaphragm4 welded version only for pressure ports according to EN 837; possible for nominal pressure ranges P N ≤ 40 barExplosion protection (only for 4 … 20 mA / 2-wire)Approval AX14-DS 400IBExU 06 ATEX 1050 XZone 0: II 1G Ex ia IIC T4 Ga (connector) / II 1G Ex ia IIB T4 Ga (cable)Safety techn. maximum values U i = 28 V, I i = 93 mA, P i = 660 mW, C i ≈ 0 pF, L i ≈ 0 µHMax. switching current 570 mAPermissible temperatures forenvironmentin zone 0: -20 ... 60 °C with p atm 0.8 bar up to 1.1 barin zone 1: -25 ... 70 °CConnecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 100 pF/mcable inductance: signal line/shield also signal line/signal line: 1 µH/m5 the real switching current in the application depends on the power supply unitwww.bdsensors.com


DS 400Technical DataDS 400Electronic Pressure SwitchTechnical Data7MiscellaneousDisplayCurrent consumption(without contacts)4-digit, 7-segment-LED display, visible range 37.2 x 11 mm; digit height 10 mm,range of indication -1999 ... +9999; accuracy 0.1 % ± 1 digit; digital damping 0.3 … 30 sec (programmable);measured value update 0.0 … 10 sec (programmable)2-wire signal output current: max. 25 mA3-wire signal output current: approx. 30 mA + signal current3-wire signal output voltage: approx. 30 mAIngress protection IP 67Installation position any 6Weightapprox. 400 gOperational life> 100 x 10 6 cyclesCE-conformity EMC Directive: 2004/108/EC Pressure Equipment Directive: 97/23/EC (module A) 76 Pressure switches are calibrated in a vertical position with the pressure connection down. If this position is changed on installation there can be slightdeviation in the zero point for pressure ranges P N ± 1 bar.7 This directive is only valid for devices with maximum permissible overpressure > 200 barWiring diagrams2-wire-system (current)supply +p3-wire-system (current / voltage)supply +pVSsupply –RLV Ssupply –signal +A / VRLIcontact 1contact 2RLcontact 1I/Ucontact 2RLPin configurationElectrical connectionSupply +Supply –Signal + (only 3-wire)Contact 1Contact 2ShieldElectrical connection (dimensions in mm)M12x1 metal (5-pin)13245plug housing / pressure portM12x1 (5-pin)Designs 8 side display 45° display (on request)8 all designs in horizontal rotatable housing as standardwww.bdsensors.com


8DS 400Technical DataDS 400Electronic Pressure SwitchTechnical DataMechanical connections (dimensions in mm)standardG1/2" DIN 3852for nominal pressure P N > 400 bar increases the length of devices without IS-vesion by 19 mm and of devices withIS-version by 39 mmoptionallyG1/2" EN 837 G1/4" DIN 3852 G1/4" EN 8371/2" NPT 1/4" NPT G1/2" flush DIN 3852(PN from 0.1 up to 40 bar) metric threads and other versions on requestThis price list contains product specifications; properties are not guaranteed. Subject to change without notice.This data sheet contains product specification, properties are not guaranteed. Subject to change without notice.www.bdsensors.comDS400_E_110213


DS 400Ordering Code9Ordering code DS 400DS 400- - - - - - - - -Pressure1gaugeabsolute7 A 07 A 1Input[bar]0.10 1 0 0 00.16 1 6 0 00.25 2 5 0 00.40 4 0 0 00.60 6 0 0 01.0 1 0 0 11.6 1 6 0 12.5 2 5 0 14.0 4 0 0 16.0 6 0 0 110 1 0 0 216 1 6 0 225 2 5 0 240 4 0 0 260 6 0 0 2100 1 0 0 3160 1 6 0 3250 2 5 0 3400 4 0 0 3600 6 0 0 3-1 … 0customerX 1 0 29 9 9 9 consultDesignStainless steel globe housing(side display)K HStainless steel globe housing(45° display)K 4consultAnalogue outputwithout4 … 20 mA / 2-wire0 … 10 V / 3-wire, adjustable4 … 20 mA / 3-wire, adjustable2Intrinsic safety 4 … 20 mA / 2-wirecustomer0137E9 consultContact1 contact22 contacts12Accuracystandard for P N ≥ 0.4 bar 0.35 % 3standard for P N < 0.4 bar0.5 % 5option 1 for P N ≥ 0.4 bar0.25 % 2customer9 consultElectrical connectionMale plug M12x1 (5-pin) /metal versionN 1 1customer9 9 9 consultMechanical connectionG1/2" DIN 3852G1/2" EN 837G1/4" DIN 3852G1/4" EN 8371 0 02 0 03 0 04 0 0G1/2" DIN 3852 with3flush sensor1/2" NPT1/4" NPTcustomerF 0 0N 0 0N 4 09 9 9 consultSealsFKM4without (welded version)12 consultNBRcustomer59 consultSpecial versionstandardcustomer0 0 09 9 9 consult1 from 60 bar: measurement starts with ambient pressure2 with Ex version max. 1 contact is possible3 only possible for nominal pressure ranges P N ≤ 40 bar4 welded version only with pressure ports according to EN 837; possible for nominal pressure ranges P N ≤ 40 bar21.01.2013This price list contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet.Subject to change without notice.www.bdsensors.com


10pressure switch with displayDS 401Intelligent ElectronicPressure SwitchStainless SteelCeramic Sensoraccuracy according to IEC 60770:0.5 % FSONominal pressurefrom 0 ... 400 mbar up to 600 barContacts1 or 2 independent PNP contacts,freely configurableAnalogue output2-wire: 4 ... 20 mA3-wire: 4 … 20 mA / 0 … 10 Vothers on requestSpecial characteristics►►indication of measured valueson a 4-digit LED displayrotatable and configurable displaymoduleOptional versions►►►IS-versionEx ia = intrinsically safe for gasespressure port PVDFcustomer specific versionsThe electronic pressure switch DS 401 is thesuccessful combination of►►intelligent pressure switchdigital displayand has been specially designed for universalusage in industry applications; with flushdiaphragm the DS 401 is suitable for the usagein viscous, pasty or highly contaminated media.The rotatable stainless steel housing is predestinedfor rough conditions and difficult installingconditions, caused by the high functionality androbustness. As standard the DS 401 offers aPNP contact and is optionally available with asecond, independent contact. Additionally theDS 401 could be equipped with an analogueoutputPreferred areas of use arePlant and Machine EngineeringEnvironmental Engineering(water – sewage – recycling)WaterHydraulic OilBD www.bdsensors.comSENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.com


DS 401Technical DataDS 401Electronic Pressure SwitchTechnical Data11Input pressure rangesNominal pressure gauge [bar] -1…0 0.4 0.6 1 1.6 2.5 4 6 10 16 25 40 60 100 160 250 400 600Nominal pressure abs. [bar] - - 0.6 1 1.6 2.5 4 6 10 16 25 40 60 100 160 250 400 600Level gauge [mH 2O] - 4 6 10 16 25 40 60 100 160 250 400 600 - - - - -Overpressure [bar] 4 1 2 2 4 4 10 10 20 40 40 100 100 200 400 400 600 800Burst pressure ≥ [bar] 7 2 4 4 5 5 12 12 25 50 50 120 120 250 500 500 650 880Vacuum resistanceP N ≥ 1 bar: unlimited vacuum resistanceP N < 1 bar: on requestContact 1Number, typestandard: 1 PNP contactoption: 2 independent PNP contactsMax. switching current 4 ... 20 mA / 2- and 3-wire: contact rating 125 mA, short-circuit resistant; V Switch = V S - 2V0 ... 10 V / 3-wire: contact rating 500 mA, short-circuit resistantAccuracy of contacts 2≤ ± 0.5 % FSORepeatability≤ ± 0.2 % FSOSwitching frequency 2-wire: max. 10 Hz / 3-wire: 50 HzSwitching cycles > 100 x 10 6Delay time0 ... 100 sec1 with Ex-protection max. 1 contact possible2 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)Analogue output (optionally) / Supply2-wire current signal4 ... 20 mA / V S = 13 ... 36 V DCpermissible load: R max = [(V S – V S min) / 0.02 A] Ωresponse time: < 10 msec2-wire current signal,Ex-protection4 ... 20 mA / V S = 13 ... 28 V DCpermissible load: R max = [(V S – V S min) / 0.02 A] Ωresponse time: < 10 msec3-wire current signal 4 ... 20 mA / V S = 24 V DC ± 10 % adjustable (turn-down of span 1:5) 3permissible load: R max = 500 Ωresponse time: < 30 msec3-wire voltage signal 0 … 10 V / V S = 24 V DC ± 10 % adjustable (turn-down of span 1:5) 3permissible load: R min = 10 kΩresponse time: < 30 msecWithout analogue output V S = 15 ... 36 V DCAccuracy 2≤ ± 0.5 % FSO3 with turn-down of span the analogue signal is adjusted automatically to the new measuring rangeThermal effects (Offset and Span) / Permissible temperaturesThermal error≤ ± 0.2 % FSO / 10 Kin compensated range -25 ... 85 °CPermissible temperatures medium: -40 ... 125 °Celectronics / environment: -40 ... 85 °Cstorage: -40 ... 100 °C4 for pressure port of PVDF the minimum permissible temperature is -30 °CElectrical protectionShort-circuit protectionReverse polarity protectionElectromagneticcompatibilityMechanical stabilitypermanentno damage, but also no functionemission and immunity according to EN 61326Vibration 10 g RMS (25 ... 2000 Hz) according to DIN EN 60068-2-6Shock 500 g / 1 msec according to DIN EN 60068-2-27MaterialsPressure port / housing1.4404 (316L)PVDF (for P N ≤ 60 bar, G1/2” open port )1.4404 (316L)HousingDisplay housing stainless steel 1.4301 (304)Viewing glasslaminated safety glassSealsstandard: FKMoption: EPDM (P N ≤ 160 bar), NBRothers on requestDiaphragm ceramics Al 2O 3 96 %Media wetted partspressure port, seals, diaphragmwww.bdsensors.com


12DS 401Technical DataDS 401Electronic Pressure SwitchTechnical DataExplosion protection (only for 4 … 20 mA / 2-wire)Approval AX14-DS 401 IBExU06ATEX1050 X zone 0: II 1G Ex ia IIC T4 Ga (connector) / II 1G Ex ia IIB T4 Ga (cable)Safety technical maximum values U i = 28 V, I i = 93 mA, P i = 660 mW, C ≈ 0 nF, L i ≈ 0 µHMax. switching current 570 mAPermissible temperatures for in zone 0: -20 ... 60 °C with p atm 0.8 bar up to 1.1 barenvironmentin zone 1: -25 ... 70 °CConnecting cablescable capacitance: signal line/shield also signal line/signal line: 100 pF/m(by factory)cable inductance: signal line/shield also signal line/signal line: 1 µH/m5 the real switching current in the application depends on the power supply unitMiscellaneousDisplay4-digit, 7-segment-LED display, visible range 37.2 x 11 mm; digit height 10 mm,range of indication -1999 ... +9999; accuracy 0.1 % ± 1 digit; digital damping 0.3 … 30 sec (programmable);measured value update 0.0 … 10 sec (programmable)Option oxygen application 6 for P N ≤ 15 bar: O-ring in 70 EPDM 281 (with BAM-approval); permissible maximum values are15 bar / 60° C and 10 bar / 90° Cfor P N ≤ 25 bar: O-ring in FKM Vi 567 (with BAM-approval); permissible maximum values are25 bar / 150° CCurrent consumption(without contacts)2-wire signal output current:3-wire signal output current:3-wire signal output voltage:max. 25 mAapprox. 30 mA + signal currentapprox. 30 mAIngress protection IP 67Installation positionanyWeightapprox. 400 gOperational life> 100 x 10 6 pressure cyclesCE-conformity EMC Directive: 2004/108/EC Pressure Equipment Directive: 97/23/EC (module A) 76 not possible with flush pressure ports7 This directive is only valid for devices with maximum permissible overpressure > 200 barWiring diagrams2-wire-system (current)supply +pIsupply –contact 1contact 2RLVSRL3-wire-system (current / voltage)supply +psupply –signal +contact 1I/Ucontact 2A / VRLVSRLPin configurationElectrical connectionsSupply +Supply –Signal + (only 3-wire)Contact 1Contact 2ShieldElectrical connections (dimensions in mm)M12x1 metal (5-pin)13245plug housing / pressure portM12x1 (5-pin)Design 8 side display 45° display (on request)8 all designs in horizontal rotatable housing as standardwww.bdsensors.com


DS 401Technical DataDS 401Electronic Pressure SwitchTechnical Data13Mechanical connections (dimensions in mm)standardG1/2" DIN 3852optionallyG1/4" DIN 3852 G1/2" EN 837 G1/4" EN 837 G1/2" open portDIN 3852 metric threads and other versions on request1/2" NPT 1/4" NPT G1/2" flush DIN 3852(PN from 0.4 up to 40 bar)This document contains product specifications; properties are not guaranteed. Subject to change without notice.This data sheet contains product specification, properties are not guaranteed. Subject to change without notice.www.bdsensors.comDS401_E_130213


14DS 401Ordering CodeOrdering code DS 401DS 401- - - - - - - - - - -Pressuregaugegauge in mH 2 Oabsolute7 A 27 A E7 A 3Input [mH 2 O] [bar]4 0.4 4 0 0 06 0.6 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1100 10 1 0 0 2160 16 1 6 0 2250 25 2 5 0 2400 40 4 0 0 2600 60 6 0 0 2100 1 0 0 3160 1 6 0 3250 2 5 0 3400 4 0 0 3600 6 0 0 3-1 … 0 X 1 0 2customer 9 9 9 9 consultDesignStainless steel globe housing(side display)K HStainless steel globe housing(45° display)K 4consultAnalogue outputwithout4 … 20 mA / 2-wire0 … 10 V / 3-wire, adjustable4 … 20 mA / 3-wire, adjustable1Intrinsic safety 4 … 20 mA / 2-wirecustomer0137E9 consultContact1 contact12 contacts12Accuracy0.5 %customer59 consultElectrical connectionMale plug M12x1 (5-pin) /metal versionN 1 1customer9 9 9 consultMechanical connectionG1/2" DIN 3852G1/2" EN 837G1/4" DIN 3852G1/4" EN 837G1/2" DIN 3852 with2flush sensor1 0 02 0 03 0 04 0 0F 0 0G1/2" DIN 3852 open pressure port1/2" NPT1/4" NPTcustomerH 0 0N 0 0N 4 09 9 9 consultSealsFKM 13EPDM 3NBRcustomer59 consultPressure portStainless steel 1.4404 (316L)4PVDFcustomer1B9 consultDiaphragmCeramics Al 2 O 3 96%customer29 consultSpecial versionstandard5oxygen applicationcustomer0 0 00 0 79 9 9 consult1 with Ex version max. 1 contact is possible2 G1/2" flush up to 25 bar and nominal pressure abs. on request3 possible for nominal pressure ranges P N ≤ 160 bar4 PVDF only with G1/2" DIN 3852 open pressure port (up to 60 bar); Ex-protection not possible, (min. permissible temperature -30°C)5 oxygen application with FKM-seal up to 25 bar or with EPDM-seal up to 15 bar possibleThis document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet.Subject to change without notice.www.bdsensors.com13.02.2013This dokument contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.


BD SENSORS GmbHpressure switch with display15DS 200Electronic Pressure SwitchStainless Steel Sensoraccuracy according to IEC 60770:standard: 0.35 % FSOoption: 0.25 % FSONominal pressurefrom 0 ... 100 mbar up to 0 ... 600 barContacts1, 2 or 4 independent PNP contacts,freelyconfigurableAnalogue output2-wire: 4 ... 20 mA3-wire: 4 … 20 mA / 0 … 10 Vothers on requestSpecial characteristics►►indication of measured values on a4-digit LED displayrotatable and configurabledisplay moduleOptional versionsThe electronic pressure switch DS 200 is thesuccessful combination of►►intelligent pressure switchdigital displayand has been specially designed for numerousapplications in various industrial sectors.As standard the DS 200 offers a PNP contactand a rotatable display module with 4-digit LEDdisplay. Optional versions like e.g. an intrinsicallysafe version, max. 4 contacts and an analogueoutput complete the profile.Preferred areas of use arePlant and Machine EngineeringHeating and Air ConditioningEnvironmental Engineering(water – sewage – recycling)►►►IS-versionEx ia = intrinsically safe for gasespressure sensor weldedcustomer specific versionswww.bdsensors.com


16DS 200Technical DataDS 200Electronic Pressure SwitchTechnical DataInput pressure rangeNominal pressuregauge 1 / abs.[bar] -1…0 0.10 0.16 0.25 0.40 0.60 1 1.6 2.5 4 6Level gauge 1 [mH 2O] - 1 1.6 2.5 4 6 10 16 25 40 60Overpressure [bar] 5 0.5 1 1 2 5 5 10 10 20 40Burst pressure ≥ [bar] 7.5 1.5 1.5 1.5 3 7.5 7.5 15 15 25 50Nominal pressuregauge 1 / abs.[bar] 10 16 25 40 60 100 160 250 400 600Level gauge 1 [mH 2O] 100 160 250 400 600 - - - - -Overpressure [bar] 40 80 80 105 210 210 600 1000 1000 1000Burst pressure ≥ [bar] 50 120 120 210 420 420 1000 1250 1250 1250Vacuum resistanceP N ≥ 1 bar: unlimited vacuum resistance; P N < 1 bar: on request1 from 60 bar: measurement starts with ambient pressureContact 2Standard1 PNP contactOptions2 independent PNP contacts4 independent PNP contacts (possible with M12x1, 8-pin for 4 ... 20 mA/3-wire;0 ... 10 V/3-wire on request)Max. switching current 4 ... 20 mA / 2- and 3-wire: contact rating 125 mA, short-circuit resistant; V switch = V S − 2V0 ... 10 V / 3-wire: contact rating 500 mA, short-circuit resistantAccuracy of contacts 3 standard: P N < 0.4 bar: ≤ ± 0.5 % FSO P N ≥ 0.4 bar: ≤ ± 0.35 % FSOoption: P N ≥ 0.4 bar: ≤ ± 0.25 % FSORepeatability≤ ± 0.1 % FSOSwitching frequencymax. 10 HzSwitching cycles > 100 x 10 6Delay time0 ... 100 sec2 max. 1 contact for 2-wire current signal with plug ISO 4400 as well as 2-wire current signal with IS-protectionno contact possible with 3-wire in combination with plug ISO 4400Analogue output (optionally) / Supply2-wire current signal4 ... 20 mA / V S = 13 ... 36 V DCpermissible load: R max = [(V S – V S min) / 0.02 A] Ωresponse time: < 10 msec2-wire current signal withIS-protection4 ... 20 mA / V S = 13 ... 28 V DCpermissible load: R max = [(V S – V S min) / 0.02 A] Ωresponse time: < 10 msec3-wire current signal 4 ... 20 mA / V S = 19 ... 30 V DC adjustable (turn-down of span 1:5) 4permissible load: R max = 500 Ωresponse time: < 3 sec3-wire voltage signal 0 … 10 V / V S = 15 ... 36 V DC permissible load: R min = 10 kΩ response time: < 3 msecwithout analogue outputV S = 15 ... 36 V DCAccuracy 3 standard: P N < 0.4 bar: ≤ ± 0.5 % FSO; P N ≥ 0.4 bar: ≤ ± 0.35 %FSOoption: P N ≥ 0.4 bar: ≤ ± 0.25 % FSO3 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)4 with turn-down of span the analogue signal is adjusted automatically to the new measuring rangeThermal effects (Offset and Span)Nominal pressure P N [bar] -1 … 0 < 0.40 ≥ 0.40Tolerance band [% FSO] ≤ ± 0.75 ≤ ± 1 ≤ ± 0.75in compensated range [°C] -20 ... 85 0 ... 70 -20 … 85Permissible temperaturesPermissible temperatures medium: -40 ... 125 °C electronics / environment: -40 ... 85 °C storage: -40 ... 100 °CElectrical protectionShort-circuit protectionpermanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 61326Mechanical stabilityVibration 10 g RMS (25 ... 2000 Hz) according to DIN EN 60068-2-6Shock 500 g / 1 msec according to DIN EN 60068-2-27MaterialsPressure port stainless steel 1.4404 (316 L)Housing stainless steel 1.4404 (316 L)Display housingPA 6.6, polycarbonateSeals (media wetted) standard: FKM option: NBR; welded version 5 others on requestDiaphragm stainless steel 1.4435 (316 L)Media wetted partspressure port, seals, diaphragm5 welded version only for pressure ports according to EN 837; possible for nominal pressure ranges P N ≤ 40 barwww.bdsensors.com


DS 200Technical DataDS 200Electronic Pressure SwitchTechnical Data17Explosion protection (only for 4 … 20 mA / 2-wire)Approval AX14-DS 200 IBExU 06 ATEX 1050 Xzone 1: II 2G Ex ia IIC T4 Gb (connector) / II 2G Ex ia IIB T4 Gb (cable)Safety technical maximumvaluesU i = 28 V, I i = 93 mA, P i = 660 mW, C ≈ 0 nF, L i ≈ 0 µHMax. switching current 6 70 mA (max. permissible inductivity: 4.7 mH)Permissible temperatures forenvironment-20 ... 70 °CConnecting cablescable capacitance: signal line/shield also signal line/signal line: 160 pF/m(by factory)cable inductance: signal line/shield also signal line/signal line: 1 µH/m6 the real switching current in the application depends on the power supply unitMiscellaneousDisplay 4-digit, red 7-segment-LED display, digit height 7 mm, range of indication -1999 ... +9999;accuracy 0.1 % ± 1 digit; digital damping 0.3 … 30 sec (programmable);measured value update 0.0 … 10 sec (programmable)Current consumption2-wire signal output current: max. 25 mA(without contacts)3-wire signal output current: approx. 45 mA + signal current3-wire signal output voltage: approx. 45 mAIngress protection IP 65Installation position any 7WeightOperational lifemin. 160 g (depending on mechanical connection)> 100 x 10 6 cyclesCE-conformity EMC Directive: 2004/108/EC Pressure Equipment Directive: 97/23/EC (module A) 87 Pressure switches are calibrated in a vertical position with the pressure connection down. If this position is changed on installation there can be slightdeviation in the zero point for pressure ranges P N ≤ 1 bar.8 This directive is only valid for devices with maximum permissible overpressure > 200 barWiring diagrams2-wire-system (current)3-wire-system (current / voltage)pIsupply +supply –contact 1contact 2ARLRLV SpI/Usupply +supply –signal +contact 1contact 2contact 3contact 4A/VRLRLRLRLV SPin configurationElectrical connectionSupply +Supply –Signal + (only 3-wire)Contact 1Contact 2Contact 3Contact 4ShieldM12x1plastic(5-pin)13245--via pressureportElectrical connections (dimensions in mm)M12x1metal(5-pin)13245--plug housing/pressure portM12x1plastic(8-pin)1324567via pressureportISO 44001233---groundcontactBinderseries 723(5-pin)34521--plug housing/pressure portcable colours(DIN 47100)wh (white)bn (brown)gn (green)gy (grey)pk (pink)--ye/gn(yellow/green) cable outlet PVCØ = 4.9mmcable outlet PURØ = 5.7mmM12x1 (5-pin) M12x1 (8-pin) ISO 4400 Binder series 723 (5-pin) cable outlet 99 different cable types and lengths available; standard: 2 m PVC cable (without ventilation tube, permissible temperature: -5 ... 70 °C)www.bdsensors.com


18DS 200Technical DataDS 200Electronic Pressure SwitchTechnical DataMechanical connections (dimensions in mm)standardoptionally G1/2" EN 837 G1/4" DIN 3852 G1/4" EN 837G1/2" DIN 3852 1/2" NPT 1/4" NPTfor nominal pressure P N > 400 bar increases the length of devices without IS-version by 19 mm and of devices withIS-version by 39 mmmetric threads and other versions on requestoptionally for P N from 0.1 up to 40 bar G1/2" flush G3/4" flush DIN 3852DIN 3852(absolute pressure on request)This data sheet contains product specification, properties are not guaranteed. Subject to change without notice.This price list contains product specifications; properties are not guaranteed. Subject to change without notice.www.bdsensors.comDS200_E_311012


DS 200Ordering Code19Ordering code DS 200DS 200- - - - - - - -Pressure1gauge in bar1gauge in mH 2 Oabsolute in bar7 8 07 8 H7 8 1Input [mH 2 O] [bar]1 0.10 1 0 0 01.6 0.16 1 6 0 02.5 0.25 2 5 0 04 0.40 4 0 0 06 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1100 10 1 0 0 2160 16 1 6 0 2250 25 2 5 0 2400 40 4 0 0 2600 60 6 0 0 2100 1 0 0 3160 1 6 0 3250 2 5 0 3400 4 0 0 3600 6 0 0 3-1 … 0 X 1 0 2customer9 9 9 9 consultAnalogue outputwithout4 … 20 mA / 2-wire0 … 10 V / 3-wirewww.bdsensors.com0137E9 consult4 … 20 mA / 3-wire, adjustable2Intrinsic safety 4 … 20 mA / 2-wirecustomerContact2, 31 contact2, 32 contacts44 contacts124Accuracystandard for P N > 0,4 bar 0.35 % 3standard for P N ≤ 0,4 bar 0.5 % 5option for P N ≥ 0,4 bar 0.25 % 2customer9 consultElectrical connectionMale plug M12x1 (5-pin) /plastic versionN 0 14Male plug M12x1 (8-pin) /plastic versionM 5 0Male plug M12x1 (5-pin) /metal versionN 1 13Male and female plug ISO 4400Male plug Binder series 723 (5-pin)5Cable outlet incl. cablecustomer1 0 02 0 0T A 09 9 9 consultMechanical connectionG1/2" DIN 3852G1/2" EN 837G1/4" DIN 3852G1/4" EN 8371 0 02 0 03 0 04 0 06G1/2" DIN 3852 withflush sensor6G3/4" DIN 3852 withflush sensor1/2" NPT1/4" NPTcustomerF 0 0K 0 0N 0 0N 4 09 9 9 consultSealsFKM7without (welded version)12NBRcustomer59 consultSpecial versionstandardcustomer0 0 09 9 9 consult1 from 60 bar: measurement starts with ambient pressure2 with Ex version max. 1 contact is possible3 with connector ISO 4400 and output 2-wire version only max. 1 contact possible; with 3-wire version no contact possible4 4 contacts and M12x1, 8-pin only possible in combination and together with 4 ... 20 mA/3-wire; 0 ... 10 V/3-wire on request5 standard: 2 m PVC cable without ventilation tube, others on request6 not possible for nominal pressure P N > 40 bar; also not possible for vacuum ranges; for G3/4“ flush nominal pressure abs. on request7 welded version only with pressure ports according to EN 837; possible for nominal pressure ranges P N ≤ 40 barThis document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet.Subject to change without notice.11.02.2013This dokument contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.


BD SENSORS GmbH20pressure switch with displayDS 201Electronic Pressure SwitchCeramic Sensoraccuracy according to IEC 60770:0.5 % FSONominal pressurefrom 0 ... 400 mbar up to 0 ... 600 barContacts1, 2 or 4 independent PNP contacts,freely configurableAnalogue output2-wire: 4 ... 20 mA3-wire: 4 … 20 mA / 0 … 10 Vothers on requestSpecial characteristics►►indication of measured values on a4-digit LED displayrotatable and configurable displaymoduleOptional versionsThe electronic pressure switch DS 201 is thesuccessful combination of►►intelligent pressure switchdigital displayand has been specially designed for universalusage in industry applications. The DS 201 isavailable with flush pressure ports for viscous,pasty and highly contaminated media.As standard the DS 201 offers a PNP contactand a rotable display module with 4-digit LEDdisplay. Optional versions like e.g. an intrinsicallysafe version, max. 4 contacts and ananalogue output complete the profile.Preferred areas of use arePlant and Machine EngineeringEnvironmental Engineering(water – sewage – recycling)►►►IS-versionEx ia = intrinsically safe for gasespressure port PVDFcustomer specific versionswww.bdsensors.com


DS 201Technical DataDS 201Electronic Pressure SwitchTechnical Data21Input pressure range 1Nominal pressure gauge [bar] -1…0 0.4 0.6 1 1.6 2.5 4 6 10 16 25 40 60 100 160 250 400 600Nominal pressure abs. [bar] - - 0.6 1 1.6 2.5 4 6 10 16 25 40 60 100 160 250 400 600Level gauge [mH 2O] - 4 6 10 16 25 40 60 100 160 250 400 600 - - - - -Overpressure [bar] 4 1 2 2 4 4 10 10 20 40 40 100 100 200 400 400 600 800Burst pressure ≥ [bar] 7 2 4 4 5 5 12 12 25 50 50 120 120 250 500 500 650 880Vacuum resistanceP N ≥ 1 bar: unlimited vacuum resistanceP N < 1 bar: on request1 PVDF pressure port possible for nominal pressure ranges up to 60 barContact 2Standard1 PNP contactOptions2 independent PNP contacts4 independent PNP contacts (possible with M12x1, 8-pin for 4 ... 20 mA/3-wire;0 ... 10 V/3-wire on request)Max. switching current 4 ... 20 mA / 2- and 3-wire: contact rating 125 mA, short-circuit resistant; V Switch = V S - 2V0 ... 10 V / 3-wire: contact rating 500 mA, short-circuit resistantAccuracy of contacts 3≤ ± 0.5 % FSORepeatability≤ ± 0.2 % FSOSwitching frequencymax. 10 HzSwitching cycles > 100 x 10 6Delay time0 ... 100 sec2 max. 1 contact for 2-wire current signal with plug ISO 4400 as well as 2-wire current signal with IS-protectionno contact possible with 3-wire in combination with plug ISO 4400Analogue output (optionally) / Supply2-wire current signal4 ... 20 mA / V S = 13 ... 36 V DCpermissible load: R max = [(V S – V S min) / 0.02 A] Ωresponse time: < 10 msec2-wire current signal withIS-protection4 ... 20 mA / V S = 13 ... 28 V DCpermissible load: R max = [(V S – V S min) / 0.02 A] Ωresponse time: < 10 msec3-wire current signal 4 ... 20 mA / V S = 19 ... 30 V DC adjustable (turn-down of span 1:5) 4permissible load: R max = 500 Ωresponse time: < 0,5 sec3-wire voltage signal 0 … 10 V / V S = 15 ... 36 V DC permissible load: R min = 10 kΩ response time: < 10 msecWithout analogue output V S = 15 ... 36 V DCAccuracy 3≤ ± 0.5 % FSO3 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)4 with turn-down of span the analogue signal is adjusted automatically to the new measuring rangeThermal effects (Offset and Span) / Permissible temperaturesThermal error≤ ± 0.2 % FSO / 10 Kin compensated range -25 ... 85 °CPermissible temperatures 5 medium: -40 ... 125 °Celectronics / environment: -40 ... 85 °Cstorage: -40 ... 100 °C5 for pressure port of PVDF the minimum permissible temperature is -30 °CElectrical protectionShort-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 61326Mechanical stabilityVibration 10 g RMS (25 ... 2000 Hz) according to DIN EN 60068-2-6Shock 500 g / 1 msec according to DIN EN 60068-2-27MaterialsPressure port / housingpressure portStandard:Option for G1/2" open port (up to 60 bar):Options for G3/4" flush (0.6 bar ≤ P N ≤ 25 bar):Display housingPA 6.6, polycarbonateSeals (media wetted)standard: FKMoption: EPDM (P N ≤ 160 bar), NBRothers on requestDiaphragm ceramics Al 2O 3 96 %Media wetted partspressure port, seals, diaphragmstainless steel 1.4404PVDFPVDFhousingstainless steel 1.4404stainless steel 1.4404PVDFwww.bdsensors.com


22DS 201Technical DataDS 201Electronic Pressure SwitchTechnical DataExplosion protection (only for 4 … 20 mA / 2-wire)Approval AX14-DS 201IBExU 06 ATEX 1050 Xzone 1: II 2G Ex ia IIC T4 Gb (connector) / II 2G Ex ia IIB T4 Gb (cable)Safety tech. maximum values U i = 28 V, I i = 93 mA, P i = 660 mW, C ≈ 0 nF, L i ≈ 0 µHMax. switching current 6 70 mA (max. permissible inductivity: 4.7 mH)Permissible temperatures forenvironment-20 ... 70 °CConnecting cablescable capacitance: signal line/shield also signal line/signal line: 160 pF/m(by factory)cable inductance: signal line/shield also signal line/signal line: 1 µH/m6 the real switching current in the application depends on the power supply unitMiscellaneousDisplay 4-digit, red 7-segment-LED display, digit height 7 mm, range of indication -1999 ... +9999;accuracy 0.1 % ± 1 digit; digital damping 0.3 … 30 sec (programmable);measured value update 0.0 … 10 sec (programmable)Option oxygen application 7 for P N ≤ 15 bar: O-ring in 70 EPDM 281 (with BAM-approval); permissible maximum values are15 bar / 60° C and 10 bar / 90° Cfor P N ≤ 25 bar: O-ring in FKM Vi 567 (with BAM-approval); permissible maximum values are25 bar / 150° CCurrent consumption2-wire signal output current: max. 25 mA(without contacts)3-wire signal output current: approx. 45 mA + signal current3-wire signal output voltage: approx. 45 mAIngress protection IP 65Installation positionanyWeightapprox. 200 gOperational life> 100 x 10 6 cyclesCE-conformity EMC Directive: 2004/108/EC Pressure Equipment Directive: 97/23/EC (module A) 87 not possible with flush pressure ports8 This directive is only valid for devices with maximum permissible overpressure > 200 barWiring diagrams2-wire-system (current)3-wire-system (current / voltage)psupply +psupply +V Ssupply –ARLV Ssupply –signal +contact 1A/VRLRLIcontact 1contact 2RLI/Ucontact 2contact 3contact 4RLRLPin configurationElectrical connectionSupply +Supply –Signal + (only 3-wire)Contact 1Contact 2Contact 3Contact 4ShieldM12x1 plastic(5-pin)13245--via pressureportElectrical connections (dimensions in mm)M12x1metal(5-pin)13245--plug housing/pressure portM12x1 plastic(8-pin)1324567via pressureportISO 44001233---ground contactBinderseries 723(5-pin)34521--plug housing/pressure portcable colours(DIN 47100)wh (white)bn (brown)gn (green)gy (grey)pk (pink)--ye/gn(yellow/green) cable outlet PVCØ = 4.9mmcable outlet PURØ = 5.7mmM12x1 (5-pin) M12x1 (8-pin) ISO 4400 Binder series 723 (5-pin) cable outlet 99 different cable types and lengths available, permissible temperature depends on kind of cable;standard: 2 m PVC cable (without ventilation tube, permissible temperature: -5 ... 70 °C)www.bdsensors.com


DS 201Technical DataDS 201Electronic Pressure SwitchTechnical Data23Mechanical connections (dimensions in mm) G1/2" EN 837 G1/4" DIN 3852 G1/4" EN 8371/2" NPT 1/4" NPTG1/2“ DIN 3852 G1/2" (DIN 3852) G1/2" open portsemi-flush; M20x1.5 10metric threads and others on requestoptionally for P N from 0.6 up to 60 bar gauge G3/4" flush (DIN 3852)This data sheet contains product specification, properties are not guaranteed. Subject to change without notice.10 possible for nominal pressure ranges P N ≤ 40 barThis document contains product specifications; properties are not guaranteed. Subject to change without notice.www.bdsensors.comDS201_E_151112


24DS 201Ordering CodePressure7 8 27 8 E7 8 3www.bdsensors.com- - - - - - - - - -absolute in barInput [mH 2 O] [bar]4 0.4 4 0 0 06 0.6 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1100 10 1 0 0 2160 16 1 6 0 2250 25 2 5 0 2400 40 4 0 0 2600 60 6 0 0 2100 1 0 0 3160 1 6 0 3250 2 5 0 3400 4 0 0 3600 6 0 0 3-1 … 0 X 1 0 2customer9 9 9 9 consultAnalogue outputwithout4 … 20 mA / 2-wire0 … 10 V / 3-wire4 … 20 mA / 3-wire, adjustableIntrinsic safety 4 … 20 mA / 2-wire 1customerContact1 contact 1,22 contacts 1,24 contacts 3Accuracy0.5 %customerElectrical connectionMale plug M12x1 (5-pin) /plastic versionMale plug M12x1 (8-pin) / 3plastic versionMale plug M12x1 (5-pin) /metal versionMale and female plug ISO 4400 2Male plug Binder series 723 (5-pin)Cable outlet incl. cable 4customerMechanical connectionG1/2" DIN 3852G1/2" EN 837G1/4" DIN 3852G1/4" EN 8375G1/2" DIN 3852 withflush sensorG3/4" DIN 3852 with 6flush sensorG1/2" DIN 3852 open pressure port1/2" NPT0137E9 consult12459 consult1 0 02 0 0T A 09 9 9 consult1 0 02 0 03 0 04 0 0H 0 0N 0 0N 4 09 9 9 consult1/4" NPTcustomerSealsFKM 17EPDM 3NBRcustomer59 consultPressure portStainless steel 1.4404 (316L)PVDF 8customer1B9 consultDiaphragmCeramics Al 2 O 3 96%customer29 consultSpecial versionDS 2011 with Ex version max.1 contact possiblegauge in bargauge in mH 2 Ostandardoxygen application 92 with connector ISO 4400 and output 2-wire version only max. 1 contact possible; with 3-wire version no contact possible3 4 contacts and M12x1, 8-pin only possible in combination and together with 4 ... 20 mA/3-wire; 0 ... 10 V/3-wire on request4 standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 … 70 °C), others on request5 possible for nominal pressure ranges P N ≥ 0.6 bar up to PN ≤ 25 bar gauge, absolute on request6 possible for nominal pressure ranges P N ≥ 0.6 bar up to P N ≤ 60 bar gauge7 possible for nominal pressure ranges P N ≤ 160 barOrdering code DS 2018 PVDF only with G1/2" DIN 3852 open pressure port (up to 60 bar) and G3/4" DIN 3852 with flush sensor (0.6 bar ≤ P N ≤ 25 bar), (min. permissible temperature -30°C)9 oxygen application with FKM-seal up to 25 bar or with EPDM-seal up to 15 bar possible, flush version on requestN 0 1M 5 0N 1 1F 0 0K 0 0This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet.Subject to change without notice.0 0 00 0 713.02.2013This dokument contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.


pressure switch with display25DS 202Electronic Pressure Switchwelded, dry Stainless Steel Sensoraccuracy according to IEC 60770:0.5 % FSONominal pressurefrom 0 ... 6 bar up to 0 ... 600 barContacts1, 2 or 4 independent PNP contacts,freely configurableAnalogue output2-wire: 4 ... 20 mA3-wire: 4 … 20 mA / 0 … 10 Vothers on requestSpecial characteristics►►indication of measured values on a4-digit LED displayrotatable and configurable displaymoduleOptional versionsThe electronic pressure switch DS 202 is thesuccessful combination of►►robust pressure transmitterdigital displayand has been specially designed for numerousapplications in various industrial sectors.As standard the DS 202 offers a PNP contactand a rotable display module with 4-digit LEDdisplay.The transmitters are suitable for anunrestricted use in oxygen applications up to600 bar and an intrinsically safe IS-Version.Preferred areas of use areMedical TechnologyPlant and Machine EngineeringRefrigeration►►►IS-versionEx ia = intrinsically safe for gasesoxygen applicationcustomer specific versionsOxygen applicationwww.bdsensors.com


26DS 202Technical DataDS 202Electronic Pressure SwitchTechnical DataInput pressure rangeNominal pressure gauge [bar] 6 10 16 25 40 60 100 160 250 400 600Overpressure [bar] 14 35 35 70 140 140 350 350 700 1200 1200Burst pressure ≥ [bar] 35 85 85 175 350 350 850 850 1750 2800 2800Vacuum resistanceunlimitedContact 1Number, typestandard: 1 PNP contactoption: 2 independent PNP contacts4 independent PNP contacts(possible with M12x1 8-pin for 4 … 20 mA / 3-wire)Max. switching current 4 ... 20 mA / 2- and 3-wire: contact rating 125 mA, short-circuit resistant; V switch = V S − 2V0 ... 10 V / 3-wire: contact rating 500 mA, short-circuit resistantAccuracy of contacts 2≤ ± 0.5 % FSORepeatability≤ ± 0.1 % FSOSwitching frequencymax. 10 HzSwitching cycles > 100 x 10 6Delay time0 ... 100 sec1 with IS-protection max. 1 contact possibleAnalogue output (optionally) / Supply2-wire current signal4 ... 20 mA / V S = 13 ... 36 V DCpermissible load: R max = [(V S – V S min) / 0.02 A] Ω2-wire current signal with 4 ... 20 mA / V S = 13 ... 28 V DCIS-protectionpermissible load: R max = [(V S – V S min) / 0.02 A] Ω3-wire current signal 4 ... 20 mA / V S = 19 ... 30 V DC permissible load: R max = 500 kΩadjustable (turn-down of span up to 1:5) 33-wire voltage signal 0 … 10 V / V S = 15 ... 36 V DC permissible load: R min = 10 kΩwithout analogue output V S = 15 ... 36 V DCAccuracy 2≤ ± 0.5 % FSO2 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)3 with turn-down of span the analogue signal is adjusted automatically to the new measuring rangeThermal effects (Offset and Span)Thermal error± 0.3 % FSO / 10 Kin compensated range 0 … 70 °CPermissible temperaturesPermissible temperatures medium: -40 ... 125 °Celectronics / environment: -40 ... 85 °Cstorage: -40 ... 100 °CElectrical protectionShort-circuit protectionReverse polarity protectionpermanentno damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 61326Mechanical stabilityVibration 10 g RMS (25 ... 2000 Hz) according to DIN EN 60068-2-6Shock 500 g / 1 msec according to DIN EN 60068-2-27MaterialsPressure portstainless steel 1.4571 (316 Ti)Housing stainless steel 1.4404 (316 L)Display housingPA 6.6, polycarbonateSeals (media wetted)none (welded)Diaphragmstainless steel 1.4542 (17-4PH)Media wetted partspressure port, diaphragmExplosion protection (only for 4 … 20 mA / 2-wire)Approval AX14-DS 202IBExU 06 ATEX 1050 XZone 1: II 2G Ex ia IIC T4 Gb (connector) / II 2G Ex ia IIB T4 Gb (cable)Safety technical maximumvaluesU i = 28 V, I i = 93 mA, P i = 660 mW, C i ≈ 0 nF, L i ≈ 0 µHMax. switching current 4 70 mA (max. permissible inductivity: 4.7 mH)Permissible temperatures forenvironment-20 ... 70 °CConnecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 160 pF/mcable inductance: signal line/shield also signal line/signal line: 1 µH/m4 the real switching current in the application depends on the power supply unitresponse time: < 10 msecresponse time: < 10 msecwww.bdsensors.com


DS 202Technical DataDS 202Electronic Pressure SwitchTechnical Data27MiscellaneousDisplayCurrent consumption(without contacts)Ingress protection IP 65Installation position4-digit, red 7-segment-LED display,digit height 7 mm, digit width 4.85 mm (angle 10°);range of indication -1999 ... +9999; accuracy 0.1 % ± 1 digit;digital damping 0.3 … 30 sec (programmable);measured value update 0.0 … 10 sec (programmable)2-wire signal output current: max. 25 mA3-wire signal output current: approx. 45 mA + signal current3-wire signal output voltage: approx. 45 mAanyWeightmin. 160 g (depending on mechanical connection)CE-conformity EMC Directive: 2004/108/ECPressure Equipment Directive: 97/23/EC (module A) 55 This directive is only valid for devices with maximum permissible overpressure > 200 barWiring diagrams2-wire-system (current)psupply +3-wire-system (current / voltage)psupply +VSsupply –AR LV Ssupply –signal +contact 1A/VRLRLIcontact 1contact 2R LI/Ucontact 2contact 3contact 4RLRLPin configurationElectrical connectionM12x1 plastic(5-pin)Supply + 1Supply – 3Signal + (only 3-wire) 2Contact 1 4Contact 2 5Contact 3 -Contact 4 -Shieldvia pressureportElectrical connections (dimensions in mm)M12x1 metal(5-pin)13245--plug housing /pressure portM12x1 plastic(8-pin)1324567via pressureportISO 44001233---ground contactcable colours(DIN 47100)wh (white)bn (brown)gn (green)gy (grey)pk (pink)--ye/gn(yellow/green) PVC-cableØ=4.9mm,PUR-cableØ=5.7mmM12x1 (5-pin) M12x1 (8-pin) ISO 4400 Binder series 723 (5-pin) cable outlet 66 different cable types and lengths available, permissible temperature depends on kind of cable;standard: 2 m PVC cable (without ventilation tube, permissible temperature: -5 ... 70 °C)www.bdsensors.com


28DS 202Technical DataDS 202Electronic Pressure SwitchTechnical DataMechanical connections (dimensions in mm)standardoption G1/2" EN 837 G1/4" EN 837 1/4" NPTmetric threads and other versions on requestThis document contains product specifications; properties are not guaranteed. Subject to change without notice.This data sheet contains product specification, properties are not guaranteed. Subject to change without notice.www.bdsensors.comDS202_E_311012


DS 202Ordering Code29Ordering code DS 202DS 202- - - - - - - -Pressure1gauge in bar 7 8 4Input[bar]6.0 6 0 0 110 1 0 0 216 1 6 0 225 2 5 0 240 4 0 0 260 6 0 0 2100 1 0 0 3160 1 6 0 3250 2 5 0 3400 4 0 0 3600customer6 0 0 39 9 9 9 consultAnalogue outputwithout4 … 20 mA / 2-wire0 … 10 V / 3-wire4 … 20 mA / 3-wire2Intrinsic safety 4 … 20 mA / 2-wirecustomer0137E9 consultContact1 contact 2 12 contacts24 contacts 4Accuracystandard 0.5 % 5customerElectrical connectionMale plug M12x1 (5-pin) /plastic version3Male plug M12x1 (8-pin) /plastic versionMale plug M12x1 (5-pin) /metal version4Male and female plug ISO 4400Male plug Binder series 723 (5-pin)5Cable outlet incl. cablecustomerMechanical connectionG1/2" EN 837G1/4" EN 8371/4" NPTcustomerSeals9 consult1 0 02 0 0T A 09 9 9 consult2 0 04 0 0N 4 09 9 9 consultwithout (welded version)customer29 consultSpecial versionstandard0 0 0oxygen applicationcustomer0 0 79 9 9 consult1 from 60 bar: measurement starts with ambient pressure2 with Ex version max. 1 contact is possibleM 5 03 4 contacts and M12x1, 8-pin only possible in combination and together with 4 ... 20 mA/3-wire; 0 ... 10 V/3-wire on request4 with connector ISO 4400 and output 2-wire version only max. 1 contact possible; with 3-wire version no contact possible5 different cable types and lengths deliverable, standard: 2 m PVC cable without ventilation tube, optionally cable with ventilation tubeN 01N 1 121.01.2013This price list contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet.Subject to change without notice.www.bdsensors.com


BD SENSORS GmbH30pressure switch with displayDS 210Electronic Pressure SwitchWithout Media Isolationaccuracy according to IEC 60770:0.35 % FSONominal pressurefrom 0 ... 10 mbar up to 0 ... 1000 mbarContacts1, 2 or 4 independent contactsfreely configurableAnalogue output2-wire: 4 ... 20 mA3-wire: 4 … 20 mA / 0 … 10 Vothers on requestSpecial characteristics► indication of measured values on a 4-digit LED display►rotatable and configurable displaymoduleOptional versionsThe electronic pressure switch DS 210 is thesuccessful combination of►►intelligent pressure switchdigital displayand has been specially designed for measuringof very small overpressure and for vacuumapplications. Permissible media are gases,pressurized air and thin non aggressive media.As standard the DS 210 offers a PNP-contactand a rotable display module. Additional featureslike e.g. an intrinsically safe version, max.4 contacts and an analogue output complete theprofile.Preferred areas of use arePlant and Machine EngineereingHeating and Air Conditioning►►IS-versionEx ia = intrinsically safe for gasescustomer specific versionsLaboratory Techniqueswww.bdsensors.com


DS 210Technical DataDS 210Electronic Pressure SwitchTechnical Data31Input pressure rangeNominal pressure gauge [mbar] -1000 ... 0 10 16 25 40 60 100 160 250 400 600 1000Overpressure [bar] 3 0.2 0.2 0.5 0.5 0.5 1 2 3 3 3 3Burst pressure [bar] 5 0.3 0.3 0.75 0.75 0.75 1.5 3 5 5 5 5Contact 1Standard1 PNP contactOptions2 independent PNP contacts4 independent PNP contacts(possible with M12x1, 8-pin for 4 ... 20 mA/3-wire; 0 ... 10 V/3-wire on request)Max. switching current 4 ... 20 mA / 2- and 3-wire: contact rating 125 mA, short-circuit resistant; V switch = V S − 2V0 ... 10 V / 3-wire: contact rating 500 mA, short-circuit resistantAccuracy of contacts 3 standard: ≤ ± 0.35 % FSOnominal pressure ≤ 100 mbar: ≤ ± 0.5 % FSORepeatability≤ ± 0.1 % FSOSwitching frequencymax. 10 HzSwitching cycles > 100 x 10 6Delay time0 ... 100 sec1 max. 1 contact for 2-wire current signal with plug ISO 4400 as well as 2-wire current signal with Ex-protectionno contact possible with 3-wire in combination with plug ISO 4400Analogue output (optionally) / Supply2-wire current signal4 ... 20 mA / V S = 18 ... 41 V DCpermissible load: R max = [(V S – V S min) / 0,02 A] Ωresponse time: < 10 msec2-wire current signal with4 ... 20 mA / V S = 17 ... 28 V DCEx-protectionpermissible load: R max = [(V S – V S min) / 0,02 A] Ωresponse time: < 10 msec3-wire current signal 4 ... 20 mA / V S = 19 ... 30 V DC adjustable (turn-down of span max. 1:5) 2permissible load: R max = 500 Ωresponse time: < 3 sec3-wire voltage signal 0 ... 10 V / V S = 15 ... 36 V DC permissible load: R min = 10 k Ω response time: < 3 msecwithout analogue outputV S = 15 ... 36 V DCAccuracy standard: ≤ ± 0.35 % FSOnominal pressure ≤ 100 mbar: ≤ ± 0.5 % FSO2 with turn-down of span the analogue signal is adjusted automatically to the new measuring range3 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)Thermal effects (Offset and Span)Nominal pressure P N [mbar] -1000 ... 0 ≤ 100 ≤ 400 > 400Tolerance band [% FSO] ≤ ± 0.75 ≤ ± 1.5 ≤ ± 1 ≤ ± 0.75in compensated range [°C] -20 ... 85 0 ... 50 0 … 70 -20 ... 85Permissible temperaturesPermissible temperatures medium: -40 ... 125 °C electronics / environment: -40 ... 85 °C storage: -40 ... 100 °CElectrical protectionShort-circuit protectionpermanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 61326Mechanical stabilityVibration 10 g RMS (25 ... 2000 Hz) according to DIN EN 60068-2-6Shock 500 g / 1 msec according to DIN EN 60068-2-27MaterialsPressure portstainless steel 1.4404 (316L)Housingstainless steel 1.4404 (316L)Display housingPA 6.6, PolycarbonateSeal (media wetted)FKMSensorstainless steel 1.4404 (316L), silicon, Epoxy or RTV, glassMedia wetted partspressure port, seal, sensorExplosion protection (for 2-wire current signal)Approval AX14-DS 210IBExU 06 ATEX 1050 Xzone 1: II 2G Ex ia IIC T4 Gb (connector) / II 2G Ex ia IIB T4 Gb (cable)Safety technical maximumvaluesU i = 28 V, I i = 93 mA, P i = 660 mW, C ≈ 0 nF, L i ≈ 0 µHMax. switching current 470 mA (max. permissible inductivity: 4.7 mH)Permissible temperatures forenvironment-20 ... 70 °CConnecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 160 pF/mcable inductance: signal line/shield also signal line/signal line: 1 µH/m4 the real switching current in the application depends on the power supply unitwww.bdsensors.com


32DS 210Technical DataDS 210Electronic Pressure SwitchTechnical DataMiscellaneousDisplay 4-digit, red 7-segment-LED display, digit height 7 mm, range of indication -1999 ... +9999;accuracy 0.1 % ± 1 digit; digital damping 0.3 … 30 sec (programmable);measured value update 0.0 … 10 sec (programmable)Current consumption2-wire signal output current: max. 25 mA(without contacts)3-wire signal output current: approx. 45 mA + signal current3-wire signal output voltage: approx. 45 mAIngress protection IP 65Installation positionWeightOperational lifeCE-conformityWiring diagrams2-wire-system (current)anyapprox. 180 g> 100 x 10 6 cyclesEMC Directive: 2004/108/EC3-wire-system (current / voltage)psupply +psupply +VSsupply –ARLV Ssupply –signal +contact 1A/VRLRLIcontact 1contact 2RLI/Ucontact 2contact 3contact 4RLRLPin configurationElectrical connectionSupply +Supply –Signal + (only 3-wire)Contact 1Contact 2Contact 3Contact 4ShieldM12x1plastic(5-pin)13245--via pressureportElectrical connections (dimensions in mm)M12x1metal(5-pin)13245--plug housing/pressure portM12x1plastic(8-pin)1324567via pressureportISO 44001233---groundcontactBinderseries 723(5-pin)34521--plug housing/pressure portcable colours(DIN 47100)wh (white)bn (brown)gn (green)gy (grey)pk (pink)--ye/gn(yellow / green)mbarmbar mbar mbar mbar cable outlet PVCØ = 4.9mmcable outlet PURØ = 5.7mmM12x1 (5-pin) M12x1 (8-pin) ISO 4400 Binder series 723 (5-pin) cable outlet 55 different cable types and lengths available; standard: 2 m PVC cable (without ventilation tube)www.bdsensors.com


DS 210DS 210TechnicalElectronicDataPressure SwitchDS 210Mechanical connections (dimensions in mm)Electronic Pressure SwitchstandardMechanical connections (dimensions in mm)optionallyTechnical DataTechnical Data33standardoptionallymbar mbar G1/2" EN 837 G1/4" DIN 3852G1/2" EN 837 G1/4" DIN 3852G1/2" DIN 3852 G1/4" EN 837 G1/2" open portG1/2" DIN 3852 G1/4" EN 837 G1/2" open port1/2“ NPT 1/4“ NPT1/2“ NPT 1/4“ NPT metric threads and other versions on request metric threads and other versions on requestThis document contains product specifications; properties are not guaranteed. Subject to change without notice.Telefon pressure and +49 level (0) 92 35 / 98 11- 0 www.bdsensors.comTelefax +49 (0) 92www.bdsensors.com35 / 98 11- 11 info@bdsensors.deDS210_E_311012DS210_E_311012This data sheet This contains data product sheet contains specification, product properties specification, are not properties guaranteed. are not Subject guaranteed. to change Subject without to change notice. without notice.


34DS 210Ordering CodeOrdering code DS 210DS 210- - - - - - - -Pressuregauge 7 8 AInput[mbar]10 0 1 0 016 0 1 6 025 0 2 5 040 0 4 0 060 0 6 0 0100 1 0 0 0160 1 6 0 0250 2 5 0 0400 4 0 0 0600 6 0 0 01000 1 0 0 1-1000 … 0customerX 1 0 29 9 9 9 consultAnalogue outputwithout4 … 20 mA / 2-wire0 … 10 V / 3-wire4 … 20 mA / 3-wire, adjustable1Intrinsic safety 4 … 20 mA / 2-wirecustomer0137E9 consultContact1, 21 contact1, 22 contacts34 contacts124Accuracystandard for P N > 0.1 bar 0.35 % 3standard for P N ≤ 0.1 bar 0.5 % 5customer9 consultElectrical connectionMale plug M12x1 (5-pin) /plastic versionN 0 13Male plug M12x1 (8-pin) /plastic versionM 5 0Male plug M12x1 (5-pin) /metal versionN 1 12Male and female plug ISO 4400Male plug Binder series 723 (5-pin)Cable outlet incl. cable 4customer1 0 02 0 0T A 09 9 9 consultMechanical connectionSealsG1/2" DIN 3852G1/2" EN 837G1/4" DIN 3852G1/4" EN 837G1/2" DIN 3852 open pressure port1/2" NPT1/4" NPTcustomerSpecial version1 with Ex version max. 1 contact is possibleFKMcustomerstandardcustomer2 with connector ISO 4400 and output 2-wire version only max. 1 contact possible; with 3-wire version no contact possible3 4 contacts and M12x1, 8-pin only possible in combination and together with 4 ... 20 mA/3-wire; 0 ... 10 V/3-wire on request4 standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 … 70 °C), others on requestThis document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet.Subject to change without notice.1 0 02 0 03 0 04 0 0H 0 0N 0 0N 4 09 9 9 consult19 consult0 0 09 9 9 consult21.01.2013This Dokument contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.www.bdsensors.com


pressure switch with display35DS 214Electronic Pressure Switchfor very high pressureThinfilm Sensoraccuracy according to IEC 60770:standard: 0.35 % FSONominal pressurefrom 0 ... 600 bar up to 0 ... 2200 barContacts1, 2 or 4 independent PNP contacts,freely configurableAnalogue output2-wire: 4 ... 20 mA3-wire: 4 … 20 mA / 0 … 10 Vothers on requestSpecial characteristics►►►indication of measured values on a4-digit LED displaypressure sensor weldedextremely robust and excellent longtermstabilityThe electronic pressure switch DS 214 for veryhigh pressure up to 2200 bar has been designedespecially for use in plant and machineengineering as well as in mobile hydraulics.The DS 214 has one 1 contact with standardversion, this can optionally be upgraded up tofour independent contacts.Via the rotatable modul with an integrated 4-digitdisplay the DS 214 can be programmed easilyand comfortably.Preferred areas of use arePlant and Machine EngineeringCommercial Vehicles and MobileHydraulicsOptional versions►►adjustability of span and offset(4 ... 20 mA / 3-wire)customer specific versionswww.bdsensors.com


36DS 214Technical DataDS 214Electronic Pressure SwitchTechnical DataInput pressure rangeNominal pressure gauge [bar] 600 1 1000 1600 2000 2200Overpressure [bar] 800 1400 2200 2800 28001 only available with pressure port G1/2“ EN 837Contact 2Standard1 PNP contactOptions2 independent PNP contacts4 independent PNP contacts (possible with M12x1, 8-pin for 4 ... 20 mA/3-wire)Max. switching current 4 ... 20 mA / 2- and 3-wire: contact rating 125 mA, short-circuit resistant; V switch = V S − 2V0 ... 10 V / 3-wire: contact rating 500 mA, short-circuit resistantAccuracy of contacts 3 standard: ≤ ± 0.35 % FSORepeatability≤ ± 0.1 % FSOSwitching frequencymax. 10 HzSwitching cycles > 100 x 10 6Delay time0 ... 100 sec2 max. 1 contact for 2-wire current signal with plug ISO 4400no contact possible with 3-wire in combination with plug ISO 4400Analogue output (optionally) / Supply2-wire current signal4 ... 20 mA / V S = 13 ... 36 V DCpermissible load: R max = [(V S – V S min) / 0.02 A] Ωresponse time: < 10 msec3-wire current signal 4 ... 20 mA / V S = 19 ... 30 V DC adjustable (turn-down of span 1:5) 4permissible load: R max = 500 Ωresponse time: < 3 sec3-wire voltage signal 0 … 10 V / V S = 15 ... 36 V DC permissible load: R min = 10 kΩ response time: < 3 msecwithout analogue output V S = 15 ... 36 V DCAccuracy 3 standard: ≤ ± 0.35 %FSO IEC 607703 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)4 with turn-down of span the analogue signal is adjusted automatically to the new measuring rangeThermal effects (Offset and Span)Thermal error [% FSO] ≤ ± 0.25 / 10 Kin compensated range [°C] -20 ... 85Permissible temperaturesPermissible temperatures medium: -40 ... 140 °C electronics / environment: -25 ... 85 °C storage: -40 ... 100 °CElectrical protectionShort-circuit protectionPermanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 61326Mechanical stabilityVibrationShockMaterials10 g RMS (25 ... 2000 Hz)100 g / 11 msecPressure portstainless steel 1.4542 (17-4 PH)Housing stainless steel 1.4404 (316 L)Display housingPA 6.6, polycarbonateSeals (media wetted)none (welded version)Diaphragmstainless steel 1.4542 (17-4 PH)Media wetted partspressure port, diaphragmMiscellaneousDisplay 4-digit, red 7-segment-LED display, digit height 7 mm, range of indication -1999 ... +9999;accuracy 0.1 % ± 1 digit; digital damping 0.3 … 30 sec (programmable);measured value update 0.0 … 10 sec (programmable)Current consumption2-wire signal output current: max. 25 mA(without contacts)3-wire signal output current: approx. 45 mA3-wire signal output voltage: approx. 7 mA + signal currentIngress protection IP 65Installation positionWeightOperational lifeanymin. 200 g (depending on mechanical connection)> 100 x 10 6 cyclesCE-conformity EMC Directive: 2004/108/EC Pressure Equipment Directive: 97/23/EC (module A)www.bdsensors.com


DS 214Technical DataDS 214Electronic Pressure SwitchTechnical Data37Wiring diagrams2-wire-system (current) 3-wire-system (current / voltage 5 )pIpsupply +supply +V Ssupply –Asupply –contact 1contact 2RLRLsignal +contact 1contact 2I/U contact 3contact 4A/VRLRLRLRLV S5 max. 2 contacts possiblePin configurationElectrical connectionSupply +Supply –Signal + (only 3-wire)Contact 1Contact 2Contact 3Contact 4ShieldM12x1plastic(5-pin)13245--via pressureportElectrical connections (dimensions in mm)M12x1metal(5-pin)13245--plug housing/pressure portM12x1plastic(8-pin)1324567via pressureportISO 44001233---groundcontactBinderseries 723(5-pin)34521--plug housing/pressure portcable colours(DIN 47100)wh (white)bn (brown)gn (green)gy (grey)pk (pink)--ye/gn(yellow / green) cable outlet PVCØ = 4.9mmcable outlet PURØ = 5.7mmM12x1 (5-pin) M12x1 (8-pin) ISO 4400 Binder series 723 (5-pin) cable outlet 66 different cable types and lengths available; standard: 2 m PVC cable (without ventilation tube, permissible temperature: -5 ... 70 °C)Mechanical connections (dimensions in mm)standardoption G1/2" DIN 837M 20 x 1,5 internal threadThis document contains product specifications; properties are not guaranteed. Subject to change without notice.This data sheet contains product specification, properties are not guaranteed. Subject to change without notice.www.bdsensors.comDS214_E_110213


38DS 214Ordering CodeOrdering Ordering code DS code 214 DS 214DS 214DS 214- - - - - - - - - - - -Pressure Pressuregauge gauge 7 8 B 7 8 BInput Input[bar] [bar]16001600 6 0 0 3 6 0 0 31000 1000 1 0 0 4 1 0 0 41600 1600 1 6 0 4 1 6 0 42000 2000 2 0 0 4 2 0 0 42200 2200 2 2 0 4 2 2 0 4customer customer 9 9 9 9 9 9 9 9 consult consultAnalogue output Analogue outputwithout without0 04 … 20 mA 4 /… 2-wire 20 mA / 2-wire0 … 10 V / 03-wire… 10 V / 3-wire4 … 20 mA 4 /… 3-wire, 20 mA adjustable / 3-wire, adjustable137137customer customer9 9 consult consultContact Contact221 contact 1 contact222 contactscontacts334 contacts 4 contacts124124Accuracy Accuracy0.35 %customer0.35 %customer3939 consult consultElectrical connectionElectrical connectionMale plug M12x1 Male plug (5-pin) M12x1 / (5-pin) /plastic version plastic versionN 0 1 N 0 133Male plug M12x1 Male plug (8-pin) M12x1 / (8-pin) /plastic version plastic versionM 5 0 M 5 0Male plug M12x1 Male plug (5-pin) M12x1 / (5-pin) /metal version metal versionN 1 1 N 1 122Male and female Male and plug female ISO 4400 plug ISO 4400Male plug Binder Male plug series Binder 723 series (5-pin) 723 (5-pin)44Cable outlet Cable incl. cable outlet incl. cable1 0 02 0 0T A 01 0 02 0 0T A 0customer customer9 9 9 9 9 9 consult consultMechanical Mechanical connection connection55G1/2" DIN G1/2" 837 DIN 837M20x1.5 internal M20x1.5 thread internal thread2 0 0D 2 82 0 0D 2 8customer customer9 9 9 9 9 9 consult consultSeals Sealswithout (welded without version) (welded version)2 2customer customer9 9 consult consultSpecial version Special versionstandardcustomerstandardcustomer0 0 09 9 90 0 09 9 9 consult consult1 only available 1 only with available pressure with port pressure G1/2" EN port 837G1/2" EN 8372 with connector 2 with ISO connector 4400 and ISO output 4400 2-wire and version output 2-wire only max. version 1 contact only max. possible; 1 contact with possible; 3-wire version with 3-wire no contact version possible no contact possible3 4 contacts and 3 4 M12x1, contacts 8-pin and M12x1, only possible 8-pin in only combination possible in and combination together with and 4 together ... 20 mA/3-wire; with 4 ... 200 ... mA/3-wire; 10 V/3-wire 0 ... on 10 request V/3-wire on request4 standard: 2 m 4 standard: PVC cable 2 m without PVC cable ventilation without tube, ventilation others on tube, request others on request5 According to 5 EN According 837, the to pressure EN 837, port the pressure and the complement, port and the complement, at pressure over at pressure 1000 bar over must 1000 be preferably bar must be made preferably of stainless made steel of stainless with a tensile steel with a tensilestrength of R P strength > 260 N/mm² of R P > in 260 accordance N/mm² in with accordance DIN 17440. with The DIN maximum 17440. The allowed maximum pressure allowed is 1600 pressure bar! is 1600 bar!This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet.Subject to change without notice.www.bdsensors.comontains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.


pressure switch with display39DS 400PIntelligent ElectronicPressure SwitchStainless SteelProcess ConnectionsWith Flush WeldedStainless Steel Diaphragmaccuracy according to IEC 60770:standard: 0.35 % FSOoption: 0.25 % FSONominal pressurefrom 0 ... 100 mbar up to 0 ... 40 barContacts1 or 2 independent PNP contacts,freely configurableAnalogue output2-wire: 4 ... 20 mA3-wire: 4 … 20 mA / 0 … 10 Vothers on requestSpecial characteristics►►►►indication of measured valueson a 4-digit LED displayrotatable and configurabledisplay moduleconfigurable contacts(switch on / switch off points, hysteresis/ window mode, switch on / switch offdelay)hygienic versionOptional versions►►IS-versionEx ia = intrinsically safe for gasescustomer specific versionsThe electronic pressure switch DS 400P is thesuccessful combination of►►intelligent pressure switchdigital displayand has been developed for process industry;especially for food / beverage and pharmaceuticalindustry.As standard the DS 400P offers a PNP contactand a rotatable display module with 4-digit LEDdisplay.Optional versions like e.g. an intrinsically safeversion, max. 2 contacts and an analogue outputcomplete the profile.Preferred areas of use areFood and BerveragePharmaceutical IndustryMaterial and test certificates► inspection certificate 3.1according to EN 10204► test report 2.2according to EN 1020474-05BD www.bdsensors.comSENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.com


40DS 400PTechnical DataDS 400PElectronic Pressure SwitchTechnical DataInput pressure range 1Nominal pressuregauge / abs.[bar] -1 ... 0 0.1 0.16 0.25 0.4 0.6 1 1.6 2.5 4 6 10 16 25 40Overpressure [bar] 5 0.5 1 1 2 5 5 10 10 20 40 40 80 80 105Burst pressure ≥ [bar] 7.5 1.5 1.5 1.5 3 7.5 7.5 15 15 25 50 50 120 120 210Vacuum resistance P N ≥ 1 bar: unlimited vacuum resistance P N < 1 bar: on request1 consider the pressure resistance of fitting and clampsContact 2Number, type standard: 1 PNP contact option: 2 independent PNP contactsMax. switching current 4 ... 20 mA / 2- and 3-wire: contact rating 125 mA, short-circuit resistant; V switch = V S − 2V0 ... 10 V / 3-wire: contact rating 500 mA, short-circuit resistantAccuracy of contacts 3 standard: nominal pressure < 0.4 bar: ≤ ± 0.5 % FSOnominal pressure ≥ 0.4 bar: ≤ ± 0.35 % FSOoption 1: nominal pressure ≥ 0.4 bar: ≤ ± 0.25 % FSORepeatability≤ ± 0.1 % FSOSwitching frequency 2-wire: max. 10 Hz / 3-wire: 50 HzSwitching cycles > 100 x 10 6Delay time0 ... 100 sec2 with IS-protection max. 1 contact possibleAnalogue output (optionally) / Supply2-wire current signal4 ... 20 mA / V S = 13 ... 36 V DCpermissible load: R max = [(V S – V S min) / 0.02 A] Ωresponse time: < 10 msec2-wire current signal withIS-protection4 ... 20 mA / V S = 13 ... 28 V DCpermissible load: R max = [(V S – V S min) / 0.02 A] Ωresponse time: < 10 msec3-wire current signal 4 ... 20 mA / V S = 24 V DC ± 10 % adjustable (turn-down of span 1:5) 4permissible load: R max = 500 Ωresponse time: < 30 msec3-wire voltage signal 0 … 10 V / V S = 24 V DC ± 10 % adjustable (turn-down of span 1:5) 4permissible load: R min = 10 kΩresponse time: < 30 msecWithout analogue outputV S = 15 ... 36 V DCAccuracy 3 standard: nominal pressure < 0.4 bar: ≤ ± 0.5 % FSOnominal pressure ≥ 0.4 bar: ≤ ± 0.35 % FSOoption 1: nominal pressure ≥ 0.4 bar: ≤ ± 0.25 % FSO3 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)4 with turn-down of span the analogue signal is adjusted automatically to the new measuring rangeThermal errors (offset and span) 5 / Permissible temperaturesNominal pressure P N [bar] -1 … 0 < 0.40 ≥ 0.40Tolerance band [% FSO] ≤ ± 0.75 ≤ ± 1.5 ≤ ± 0.75in compensated range [°C] -20 ... 85 0 ... 50 -20 ... 85Permissible temperatures 6 medium: -40 ... 125 °C for filling fluid silicon oil-10 ... 125 °C for filling fluid food compatible oilelectronics / environment: -40 ... 85 °C storage: -40 ... 100 °CPermissible temperature mediumfor cooling element 300°Cwww.bdsensors.comfilling fluid silicon oil overpressure: -40 … 300 °C vacuum: -40 ... 150 °C 7filling fluid food compatible oil overpressure: -10 ... 250 °C vacuum: -10 ... 150 °C5 an optional cooling element can influence thermal effects for offset and span depending on installation position and filling conditions6 max. temperature of the medium for nominal pressure gauge > 0 bar: 150 °C for 60 minutes with a max. environmental temperature of 50 °C7 also for P abs < 1 barElectrical protectionShort-circuit protectionReverse polarity protectionpermanentno damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 61326Mechanical stabilityVibration (DIN EN 60068-2-6) G 1/2": 20 g RMS (25 ... 2000 Hz) others except G 1/2": 10 g RMS (25 … 2000 Hz)Shock (DIN EN 60068-2-27) G 1/2": 500 g / 1 msec others except G 1/2“: 100 g / 1 msecFilling fluidsStandardOptionalsilicon oilfood compatible oil (with FDA approval)(Mobil DTE FM 32; Category Code: H1; NSF Registration No.: 130662)others on requestMaterialsPressure port / Housing stainless steel 1.4404 (316 L) others on requestViewing glasslaminated safety glassSealsStandardOptionalDiaphragmMedia wetted partsFKM (recommended for medium temperatures ≤ 200 °C)FFKM (recommended for medium temperatures > 200 °C)Clamp, dairy pipe, Varivent ® : withoutstainless steel 1.4435 (316L)pressure port, seal, diaphragmothers on request


DS 400PTechnical DataDS 400PElectronic Pressure SwitchTechnical Data41Explosion protection (only for 4 … 20 mA / 2-wire)Approval AX14-DS 400PSafety technical maximumvaluesMax. switching current 8Permissible temperatures forenvironmentIBExU 06 ATEX 1050 XZone 0: II 1G Ex ia IIC T4U i = 28 V, I i = 93 mA, P i = 660 mW, C ≈ 0 nF, L i ≈ 0 µH70 mAin zone 0: -20 ... 60 °C with p atm 0.8 bar up to 1.1 barin zone 1: -25 ... 70 °CConnecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 100 pF/mcable inductance: signal line/shield also signal line/signal line: 1 µH/m8 the real switching current in the application depends on the power supply unitMiscellaneousDisplayCurrent consumption(without contacts)Ingress protection IP 67Installation positionWeightOperational lifeCE-conformityWiring diagrams2-wire-system (current)psupply +Isupply –contact 1contact 2Pin configurationElectrical connectionDesigns 9RVSRLSupply +Supply –Signal + (only 3-wire)Contact 1Contact 2Shield4-digit, 7-segment-LED display, visible range 37.2 x 11 mm; digit height 10 mm,range of indication -1999 ... +9999; accuracy 0.1% ± 1 digit; digital damping 0.3 … 30 sec(programmable); measured value update 0.0 … 10 sec (programmable)2-wire signal output current:3-wire signal output current:3-wire signal output voltage:max. 25 mAapprox. 30 mA + signal currentapprox. 30 mAany (standard calibration in a vertical position with the pressure port connection down;differing installation position for P N ≤ 4 bar have to be specified in the order)min. 500 g (depending on mechanical connection)> 100 x 10 8 cyclesEMC Directive: 2004/108/EC3-wire-system (current / voltage)supply +psupply –signal +contact 1I/Ucontact 2A / VRVSRLM12x1 metal(5-pin)13245plug housing / pressure portElectrical connections (dimensions in mm)side display 45° display (others on request) M12x1 (5-pin)9 all designs in horizontal rotatable housing as standardwww.bdsensors.com


42DS 400PDS 400PTechnical Electronic Data Pressure SwitchDS 400PMechanical connections (dimensions in mm)Electronic Pressure SwitchStandardOptionTechnical DataTechnical DataMechanical connections (dimensions in mm)StandardOptionG1/2" flush DIN 3852 G 3/4" flush DIN 3852(PN ≥ 1 bar)G1/2" flush DIN 3852 G 3/4" flush DIN 3852(PN ≥ 1 bar)OptionOptionG1" flush DIN 3852 G1/2" flush G1" flush G1" conewith radial o-ringwith radial o-ring (PN ≤ 2 bar)G1" flush DIN 3852 G1/2" flush G1" flush G1" conewith radial o-ringwith radial o-ring (PN ≤ 2 bar)74-0574-05Varivent® dairy pipe (DIN 11851) clamp (DIN 32676) cooling element 300 °CPN ≤ 25 bardimension in mmdimension in mmsize DN 25 DN 40 DN 50 size ¾“ DN 25 DN 32 DN 50Varivent® A dairy 23 pipe (DIN 32 11851) 45 A clamp 14 (DIN 32676) 23 32 45 cooling element 300 °CPN ≤ 25 barB 44 56 68.5 B 25 50.5 50.5 64PNPN≤ 40 ≤ 40 ≤ 25≤ 8 ≤ 16 ≤ 16 ≤ 16[bar]dimension in mm[bar]dimension in mmsize DN 25 DN 40 DN 50 size ¾“ DN 25 DN 32 DN 50A 23 32 45 A 14 23 32 45B 44 56 68.5 B 25 50.5 50.5 64 metric threads and other versions on request PNPN≤ 40 ≤ 40 ≤ 25[bar][bar]≤ 8 ≤ 16 ≤ 16 ≤ 16This document contains product specifications; properties are not guaranteed. Subject to change without notice. metric threads and other versions on request74-0574-05DS400P_E_080313This datasheet This contains datasheet product contains specification, product properties specification, are not properties guaranteed. are not Subject guaranteed. to change Subject without to change notice. without notice.Tel: pressure +49 and (0) level 92 35 / 98 11- 0 www.bdsensors.comFax: +49 (0) 92 35 / 98 11- 11 info@bdsensors.dewww.bdsensors.comDS400P_E_080313


DS 400POrdering Code43DS 400P- - - - - - - - - - -Pressuregauge1absolute7 A 57 A 6Input[bar]0.10 1 0 0 00.16 1 6 0 00.25 2 5 0 00.40 4 0 0 00.60 6 0 0 01.0 1 0 0 11.6 1 6 0 12.5 2 5 0 14.0 4 0 0 16.0 6 0 0 110 1 0 0 216 1 6 0 225 2 5 0 240 4 0 0 2-1 … 0customerX 1 0 29 9 9 9 consultDesignStainless steel globe housing(side display)K HStainless steel globe housing(45° display)K 4consultAnalogue outputwithout4 … 20 mA / 2-wire0 … 10 V / 3-wire, adjustable4 … 20 mA / 3-wire, adjustable2Intrinsic safety 4 … 20 mA / 2-wirecustomer0137E9 consultContact1 contact22 contacts12Accuracystandard for P N ≥ 0,4 bar 0.35 % 3standard for P N < 0,4 bar 0.5 % 5option for P N ≥ 0,4 bar 0.25 % 2customer9 consultElectrical connectionMale plug M12x1 (5-pin) /metal versionN 1 1customer9 9 9 consultMechanical connectionG1/2" with flush3welded diaphragm (DIN 3852)Z 0 0G3/4" with flushwelded diaphragm (DIN 3852)Z 3 0G1" with flushwelded diaphragm (DIN 3852)Z 3 1G1" DIN 3852 with rad. o-ring4and flush diaphragmZ 5 7G1/2" DIN 3852 with rad. o-ringand flush diaphragmZ 6 1G 1" coneClamp DN 25 (DIN 32676) / 3AClamp DN 32 (DIN 32676) / 3AClamp DN 50 (DIN 32676) / 3AClamp 3/4" (DIN 32676) / 3A5Dairy pipe DN 25 (DIN 11851)5Dairy pipe DN 40 (DIN 11851)5Dairy pipe DN 50 (DIN 11851)Varivent ® DN 40/50 / 3AcustomerK 3 1C 6 1C 6 2C 6 3C 6 9M 7 3M 7 5M 7 6P 4 19 9 9 consultDiaphragmStainless steel 1.4435 (316L)customer19 consultSealsfor clamp, dairy pipe, Varivent ® : none 0for inch thread: FKM 1FFKM 7 consultcustomer9 consultFilling FluidsSilicon oilfood compatible oil (FDA)customer129 consultSpecial versionstandardwith cooling element up to 300°Ccustomer0 0 02 0 09 9 9 consult1 absolute pressure possible from 1 bar2 with Ex version max. 1 contact is possible3 only possible for nominal pressure ranges P N ≥ 1 bar4 only possible for nominal pressure ranges P N ≤ 2 bar5 The cup nut for dairy pipe has to be mounted by production of pressure transmitter. The cup nut has to be ordered as separate position.Varivent ® is a brand name of GEA Tuchenhagen GmbHOrdering code DS 400PThis document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet.Subject to change without notice.07.03.2013This dokument contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.


44pressure switch with displayDS 200PElectronic Pressure SwitchProcess ConnectionsWith Flush WeldedStainless Steel Diaphragmaccuracy according to IEC 60770:standard: 0.35 % FSOoption: 0.25 % FSONominal pressurefrom 0 ... 100 mbar up to 0 ... 40 barContacts1, 2 or 4 independent PNP contacts,freely configurableAnalogue output2-wire: 4 ... 20 mA3-wire: 4 … 20 mA / 0 … 10 Vothers on requestSpecial characteristics►►►indication of measured values ona 4-digit LED displayrotatable and configurabledisplay moduleconfigurable contacts(switch on/switch off points, hysteresis/windowmode, switch on/switch offOptional versions►IS-versionEx ia = intrinsically safe for gasesThe electronic pressure switch DS 200P is thesuccessful combination of►►intelligent pressure switchdigital displayand is suitable for the usage with viscous andpasty media.As standard the DS 200P offers a PNP contactand a rotatable display module with4-digit LED display. Optional versions like e.g.an intrinsically safe version, max. 4 contacts andan analogue output complete the profile.Preferred areas of use areFood and BeveragePharmaceutical IndustryMaterial and test certificates► inspection certificate 3.1according to EN 10204► test report 2.2according to EN 10204►customer specific versions74-05BD www.bdsensors.comSENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.com


DS 200PTechnical DataDS 200PElectronic Pressure SwitchTechnical Data45Input pressure range 1Nominal pressure (P N)gauge / abs.[bar]-1 ... 0 0.10 0.16 0.25 0.40 0.60 1 1.6 2.5 4 6 10 16 25 40Overpressure [bar] 5 0.5 1 1 2 5 5 10 10 20 40 40 80 80 105Burst pressure ≥ [bar] 7.5 1.5 1.5 1.5 3 7.5 7.5 15 15 25 50 50 120 120 210Vacuum resistance P N ≥ 1 bar: unlimited vacuum resistance P N < 1 bar: on request1 consider the pressure resistance of fitting and clampsContact 2Standard1 PNP contactOptions2 independent PNP contacts4 independent PNP contacts (possible with M12x1, 8-pin for 4 ... 20 mA/3-wire;0 ... 10 V/3-wire on request)Max. switching current 4 ... 20 mA / 2- and 3-wire: contact rating 125 mA, short-circuit resistant; V Switch = V S - 2V0 ... 10 V / 3-wire: contact rating 500 mA, short-circuit resistantAccuracy of contacts 3 standard: P N < 0.4 bar: ≤ ± 0.5 % FSO P N ≥ 0.4 bar: ≤ ± 0.35 % FSOoption: P N ≥ 0.4 bar: ≤ ± 0.25 % FSORepeatability≤ ± 0.1 % FSOSwitching frequencymax. 10 HzSwitching cycles > 100 x 10 6Delay time0 ... 100 sec2 max. 1 contact for 2-wire current signal with plug ISO 4400 as well as 2-wire current signal with IS-protectionno contact possible with 3-wire in combination with plug ISO 44003 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)Analogue output (optionally) / Supply2-wire current signal4 ... 20 mA / V S = 13 ... 36 V DCpermissible load: R max = [(V S – V S min) / 0.02 A] Ωresponse time: < 10 msec2-wire current signal withIS-protection4 ... 20 mA / V S = 13 ... 28 V DCpermissible load: R max = [(V S – V S min) / 0.02 A] Ωresponse time: < 10 msec3-wire current signal 4 ... 20 mA / V S = 19 ... 30 V DC adjustable (turn-down of span 1:5) 4permissible load: R max = 500 Ωresponse time: < 0.5 sec3-wire voltage signal 0 … 10 V / V S = 15 ... 36 V DC permissible load: R min = 10 kΩ response time: < 10 msecWithout analogue output V S = 15 ... 36 V DCAccuracy 3 standard: P N < 0.4 bar: ≤ ± 0.5 % FSO P N ≥ 0.4 bar: ≤ ± 0.35 % FSOoption: P N ≥ 0.4 bar: ≤ ± 0.25 % FSO4 with turn-down of span the analogue signal is adjusted automatically to the new measuring rangeThermal errors (Offset and Span) 5 / Permissible temperaturesNominal pressure P N [bar] -1 … 0 < 0.40 ≥ 0.40Tolerance band [% FSO] ≤ ± 0.75 ≤ ± 1.5 ≤ ± 0.75in compensated range [°C] -20 ... 85 0 ... 50 -20 ... 85Permissible temperatures 6 medium: -40 ... 125 °C for filling fluid silicon oil-10 ... 125 °C for filling fluid food compatible oilelectronics / environment: -40 ... 85 °C storage: -40 ... 100 °CPermissible temperature medium filling fluid silicon oil overpressure: -40 … 300 °C vacuum: -40 ... 150 °C 7for cooling element 300°C filling fluid food compatible oil overpressure: -10 ... 250 °C vacuum: -10 ... 150 °C5 an optional cooling element can influence thermal effects for offset and span depending on installation position and filling conditions.6 max. temperature of the medium for nominal pressure gauge > 0 bar: 150 °C for 60 minutes with a max. environmental temperature of 50 °C7 also for P abs < 1 barElectrical protectionShort-circuit protectionpermanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 61326Mechanical stabilityVibration 5 g RMS (25 ... 2000 Hz) according to DIN EN 60068-2-6Shock 100 g / 11 msec according to DIN EN 60068-2-27Filling fluidsStandardsilicon oilOptionsfood compatible oil (with FDA approval)(Mobil DTE FM 32; Category Code: H1; NSF Registration No.: 130662) others on requestMaterialsPressure port / Housing stainless steel 1.4404 (316 L) others on requestDisplay housingPA 6.6, PolycarbonateSeals (media wetted)StandardFKM (recommended for medium temperatures ≤ 200 °C)Option FFKM (recommended for medium temperatures > 200 °C) others on requestClamp, dairy pipe, Varivent ® : withoutDiaphragmStandard stainless steel 1.4435 (316 L)Option Hastelloy ® C-276 (2.4819) Tantalum on requestMedia wetted partspressure port, seal, diaphragmwww.bdsensors.com


46DS 200PTechnical DataDS 200PElectronic Pressure SwitchTechnical DataExplosion protection (only for 4 … 20 mA / 2-wire)Approval AX14-DS 200P IBExU06ATEX1050 Xzone 1: II 2G Ex ia IIC T4 Gb (connector) / II 2G Ex ia IIB T4 Gb (cable)Safety technical maximumUvaluesi = 28 V, I i = 93 mA, P i = 660 mW, C ≈ 0 nF, L i ≈ 0 µHMax. switching current 8 70 mA (max. permissible inductivity: 4.7 mH)Permissible temperatures forenvironment-25 ... 70 °CConnecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 100 pF/mcable inductance: signal line/shield also signal line/signal line: 1 µH/m8 the real switching current in the application depends on the power supply unitMiscellaneousDisplay 4-digit, red 7-segment-LED display, digit height 7 mm, range of indication -1999 ... +9999;accuracy 0.1 % ± 1 digit; digital damping 0.3 … 30 sec (programmable);measured value update 0.0 … 10 sec (programmable)Current consumption2-wire signal output current: max. 25 mA(without contacts)3-wire signal output current: approx. 45 mA + signal current3-wire signal output voltage: approx. 45 mAIngress protection IP 65Installation positionany (standard calibration in a vertical position with the pressure port connection down;different installation position for P N ≤ 2 bar have to be specified in the order)WeightOperational lifeCE-conformityWiring diagrams2-wire-system (current)approx. 160 ... 250 g> 100 x 10 6 cyclesEMC Directive: 2004/108/EC3-wire-system (current / voltage)psupply +psupply +VSVSsupply –ARLsupply –signal +contact 1A/VRLRLIcontact 1contact 2RLI/Ucontact 2contact 3contact 4RLRLPin configurationElectrical connectionSupply +Supply –Signal + (only 3-wire)Contact 1Contact 2Contact 3Contact 4ShieldM12x1 plastic(5-pin)13245--via pressureportElectrical connections (dimensions in mm)M12x1metal(5-pin)13245--plug housing/pressure portM12x1plastic(8-pin)1324567via pressureportISO 44001233---groundcontactBinderseries 723(5-pin)34521--plug housing/pressure portcable colours(DIN 47100)wh (white)bn (brown)gn (green)gy (grey)pk (pink)--ye/gn(yellow / green) cable outlet PVCØ = 4.9mmcable outlet PURØ = 5.7mmM12x1 (5-pin) M12x1 (8-pin) ISO 4400 Binder series 723 (5-polig) cable outlet 77 different cable types and lengths available, permissible temperature depends on kind of cable;standard: 2 m PVC cable (without ventilation tube, permissible temperature: -5 ... 70°C)www.bdsensors.com


DS 200PTechnical DataDS 200PElectronic Pressure SwitchTechnical Data47Mechanical connections (dimensions in mm)StandardOption G1/2" flush(PN ≥ 1 bar)G3/4" flushOption G1" flush G1/2" flush with G1" flush with G1" coneradial o-ringradial o-ring ( PN ≤ 2 bar) Varivent® dairy pipe (DIN 11851) clamp (DIN 32676) cooling element 300 °CPN ≤ 25 bardimension in mmsize DN 25 DN 40 DN 50A 23 32 45B 44 56 68.5PN[bar]≤ 40 ≤ 40 ≤ 25SIL- and SIL-Ex version: total length increases by 26.5 mm!metric threads and other versions on request 74-05 dimension in mmsize ¾” DN 25 DN 32 DN 50A 14 23 32 45B 25 50.5 50.5 64PN[bar]≤ 8 ≤ 16 ≤ 16 ≤ 16This data sheet contains product specification, properties are not guaranteed. Subject to change without notice.This document contains product specifications; properties are not guaranteed. Subject to change without notice.DS200P_E_080313


48DS 200POrdering CodePressureInputDS 200PAnalogue outputwithout4 … 20 mA / 2-wire0 … 10 V / 3-wire4 … 20 mA / 3-wire, adjustableIntrinsic safety 4 … 20 mA / 2-wirecustomerOrdering code DS 200P- - - - - - - - - -gaugeabsolute7 8 57 8 6[bar]0.10 1 0 0 00.16 1 6 0 00.25 2 5 0 00.40 4 0 0 00.60 6 0 0 01.0 1 0 0 11.6 1 6 0 12.5 2 5 0 14.0 4 0 0 16.0 6 0 0 110 1 0 0 216 1 6 0 225 2 5 0 240 4 0 0 2-1 … 0 X 1 0 2customer9 9 9 9 consult0137E9 consultContact1, 21 contact1, 22 contacts34 contacts124Accuracystandard for P N > 0,4 bar 0.35 % 3standard for P N ≤ 0,4 bar 0.5 % 5option for P N ≥ 0,4 bar 0.25 % 2customer9 consultElectrical connectionMale plug M12x1 (5-pin) /plastic versionN 0 13Male plug M12x1 (8-pin) /plastic versionM 5 0Male plug M12x1 (5-pin) /metal versionN 1 12Male and female plug ISO 4400Male plug Binder series 723 (5-pin)4Cable outlet incl. cablecustomer1 0 02 0 0T A 09 9 9 consultMechanical connectionG1/2" with flush5welded diaphragm (DIN 3852)Z 0 0G3/4" with flushwelded diaphragm (DIN 3852)Z 3 0G1" with flushwelded diaphragm (DIN 3852)Z 3 1G1" DIN 3852 with rad. o-ringand flush diaphragm 6Z 5 7Dairy pipe DN 40 (DIN 11851) 7 M 7 5G1/2" DIN 3852 with rad. o-ringand flush diaphragmZ 6 1G 1" coneClamp DN 25 (DIN 32676) / 3AClamp DN 32 (DIN 32676) / 3AClamp DN 50 (DIN 32676) / 3AClamp 3/4" (DIN 32676) / 3A7Dairy pipe DN 25 (DIN 11851)K 3 1C 6 1C 6 2C 6 3C 6 9M 7 3Dairy pipe DN 50 (DIN 11851) 7Varivent ® DN 40/50 / 3AcustomerM 7 6P 4 19 9 9 consultDiaphragmStainless steel 1.4435 (316L)Tantalum1TconsultHastelloy ® C-276 (2.4819)customerH9 consultSealsfor clamp, dairy pipe, Varivent ® : without 0for inch thread: FKM 1FFKM 7customer9 consultFilling FluidsSilicon oilfood compatible oil (FDA)customerSpecial versionstandardwith cooling element up to 300°Ccustomer1 with Ex version max. 1 contact is possible2 with connector ISO 4400 and output 2-wire version only max. 1 contact possible; with 3-wire version no contact possible3 4 contacts and M12x1, 8-pin only possible in combination and together with 4 ... 20 mA/3-wire; 0 ... 10 V/3-wire on request4 standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 … 70 °C), others on request5 possible only for P N ≥ 1 bar6 possible only for P N ≤ 2 bar1129 consult0 0 02 0 09 9 9 consult7 The cup nut for dairy pipe has to be mounted by production of pressure transmitter. The cup nut has to be ordered as separate position.Varivent ® is a brand name of GEA Tuchenhagen GmbH, Hastelloy ® is a brand name of Haynes International Inc. 07.03.2013This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet.Subject to change without notice.This dokument contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.


pressure switch with display49DS 201PElectronic Pressure SwitchPressure Port WithFlush Welded Stainless Steel Diaphragmaccuracy according to IEC 60770:0.5 % FSONominal pressurefrom 0 ... 60 bar up to 400 barContacts1, 2 or 4 independent PNP contacts,freely configurableAnalogue output2-wire: 4 ... 20 mA3-wire: 4 … 20 mA / 0 … 10 Vothers on requestSpecial characteristicsThe electronic pressure switch DS 201P is thesuccessful combination of►►intelligent pressure switchdigital displayand is designed for universal applications in themechanical engineering and other industrieswhere a flush stainless steel diaphragm is necessary.This can be the case, for example, withhigher viscous or slightly contaminated fluids.For usage with higher media temperature optionallya cooling element up to 300 °C is available.Preferred areas of use are►►indication of measured valueson a 4-digit LED displayrotatable and configurable displaymodulePlant and Machine EngineeringFood IndustryOptional versions►IS-versionEx ia = intrinsically safe for gases► cooling element up to 300 °C►customer specific versionsPreferred used forViscous and pasty mediaBD www.bdsensors.comSENSORS GmbHBD-Sensors-Straße 1 Telefon +49 (0) 92 35 / 98 11- 0 www.bdsensors.com


50DS 201PTechnical DataDS 201PElectronic Pressure SwitchTechnical DataInput pressure rangesNominal pressure gauge/abs. [bar] 60 100 160 250 400Overpressure [bar] 100 200 400 400 600Burst pressure ≥ [bar] 120 250 500 500 650Contact 1Standard1 PNP contactOptions2 independent PNP contacts4 independent PNP contacts (possible with M12x1, 8-pin for 4 ... 20 mA/3-wire;0 ... 10 V/3-wire on request)Max. switching current 4 ... 20 mA / 2- and 3-wire: contact rating 125 mA, short-circuit resistant; V switch = V S − 2V0 ... 10 V / 3-Leiter: contact rating 500 mA, short-circuit resistantAccuracy of contacts 2≤ ± 0.5 % FSORepeatability≤ ± 0.2 % FSOSwitching frequencymax. 10 HzSwitching cycles > 100 x 10 6Delay time0 ... 100 sec1 max. 1 contact for 2-wire current signal with plug ISO 4400 as well as 2-wire current signal with Ex-protection no contact possible with 3-wire in combinationwith plug ISO 44002 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)Analogue output (optionally) / Supply2-wire current signal4 ... 20 mA / V S = 13 ... 36 V DCpermissible load: R max = [(V S – V S min) / 0.02 A] Ωresponse time: < 10 msec2-wire current signal with4 ... 20 mA / V S = 13 ... 28 V DCEx-protectionpermissible load: R max = [(V S – V S min) / 0.02 A] Ω response time: < 10 msec3-wire current signal 4 ... 20 mA / V S = 19 ... 30 V DC adjustable (turn-down of span max. 1:5) 3permissible load: R max = 500 Ω response time: < 0.5 sec3-wire voltage signal0 ... 10 V / V S = 15 ... 36 V DCpermissible load: R min = 10 kΩ response time: < 10 msecwithout analogue outputV S = 15 ... 36 V DCaccuracy 2≤ ± 0.5 % FSO3 with turn-down of span the analogue signal is adjusted automatically to the new measuring rangeThermal error (offset and span) 4 / Permissible temperaturesThermal error≤ ± 0.2 % FSO / 10 Kin compensated range -20 ... 85°CPermissible temperatures 5 medium: -40 ... 125 °C for filling fluid silicon oil-10 ... 125 °C for filling fluid food compatible oilelectronics / environment: -40 ... 85 °Cstorage: -40 ... 100 °CPermissible temperaturefilling fluid silicon oil overpressure: -40 … 300 °C vacuum: -40 ... 150 °Cmedium for cooling element 300°C filling fluid food compatible oil overpressure: -10 ... 250 °C vacuum: -10 ... 150 °C4 an optional cooling element can influence thermal effects for offset and span depending on installation position and filling conditions5 max. temperature of the medium for overpressure > 0 bar: 150 °C for 60 minutes with a max. environmental temperature of 50 °Electrical protectionShort-circuit protectionpermanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 61326Mechanical stabilityVibration 5 g RMS (25 ... 2000 Hz) according to DIN EN 60068-2-6Shock 100 g / 11 msec according to DIN EN 60068-2-27Filling fluidsStandardsilicon oilOptionalfood compatible oil with FDA approval(Mobil DTE FM 32; Category Code: H1; NSF Registration No.: 130662)others on requestMaterialsPressure port stainless steel 1.4404 (316 L)Housing stainless steel 1.4404 (316 L)Display housingPA 6.6, PolycarbonateSeals standard: FKM (for media temperature ≤ 200 °C)option:FFKM 6 (for media temperature > 200 °C)others on requestDiaphragm stainless steel 1.4435Media wetted partspressure port, seals, diaphragm6 for pressure ranges P N ≤ 100 barwww.bdsensors.com


DS 201PTechnical DataDS 201 PElectronic Pressure SwitchTechnical Data51Explosion protection (only for 4 … 20 mA / 2-wire)Approval AX14-DS 201PIBExU06ATEX1050 Xzone 1: II 2G Ex ia IIC T4 Gb (connector) / II 2G Ex ia IIB T4 Gb (cable)Safety technical maximumvaluesU i = 28 V, I i = 93 mA, P i = 660 mW, C ≈ 0 nF, L i ≈ 0 µHMax. switching current 770 mA (max. permissible inductivity: 4.7 mH)Max. temperatures forenvironment-25 ... 70 °CConnecting cablescable capacitance: signal line/shield also signal line/signal line: 100 pF/m(by factory)cable inductance: signal line/shield also signal line/signal line: 1 µH/m7 the real switching current in the application depends on the power supply unitMiscellaneousDisplay 4-digit, red 7-segment-LED display, digit height 7 mm, range of indication -1999 ... +9999;accuracy 0.1 % ± 1 digit; digital damping 0.3 … 30 sec (programmable);measured value update 0.0 … 10 sec (programmable)Current consumption2-wire signal output current: max. 25 mA(without contacts)3-wire signal output current: approx. 45 mA + signal current3-wire signal output voltage: approx. 45 mAIngress protection IP 65Installation positionany (standard calibration in a vertical position with the pressure port connection down)Weightmin. 200 g (depending on mechanical connection)Operational life> 100 x 10 6 cyclesCE-conformity EMC Directive: 2004/108/EC Pressure Equipment Directive: 97/23/EC (module A) 8ATEX Directive94/9/EC8 This directive is only valid for devices with maximum permissible overpressure > 200 bar.Wiring diagrams2-wire-system (current)3-wire-system (current/voltage)psupply +psupply +VSIsupply –contact 1contact 2ARLRLV SI/Usupply –signal +contact 1contact 2contact 3contact 4A/VRLRLRLRLPin configurationElectrical connectionSupply +Supply –Signal + (only for 3-wire)Contact 1Contact 2Contact 3Contact 4ShieldM12xplastic(5-pin)13245--via pressureportElectrical connections (dimensions in mm)M12xmetal(5-pin)13245--plug housing/pressure portM12xplastic(8-pin)1324567via pressureportISO 44001233---groundcontactBinderseries 723(5-pin)34521--plug housing/pressure portcable colours(DIN 47100)wh (white)bn (brown)gn (green)gy (grey)pk (pink)--ye/gn(yellow/green) cable outlet PVCØ = 4.9mmcable outlet PURØ = 5.7mmM12x1 (5-pin) M12x1 (8-pin) ISO 4400 Binder series 723 (5-pin) cable outlet 99 different cable types and lengths available, permissible temperature depends on kind of cable;standard: 2 m PVC cable (without ventilation tube, permissible temperature: -5 ... 70°C)www.bdsensors.com


52DS 201PDS 201PDS 201PTechnical DataElectronic Pressure SwitchElectronic Pressure SwitchMechanical connection (dimensions in mm)Technical DataTechnical DataStandardMechanical connection (dimensions in mm)OptionalStandardOptional G1/2" flush G3/4" flush G1" flushOptionalG1/2" flush G3/4" flush G1" flushOptionalmetric threads and other versions on requestmetric threads and other versions on request10 for pressure ranges P N ≤ 160 barThis document contains product specifications; properties are not guaranteed. Subject to change without notice.10 for pressure ranges P N ≤ 160 barpressure Telefon and +49 level (0) 92 35 / 98 11- 0 www.bdsensors.comwww.bdsensors.comTelefax +49 (0) 92 35 / 98 11- 11 info@bdsensors.de G1" flush cooling elementwith radial o-ring 300 °C 10G1" flush cooling elementwith radial o-ring 300 °C 10DS201P_E_130213DS201P_E_130213This data sheet This data contains sheet product contains specification, product specification, properties are properties not guaranteed. are not guaranteed. Subject to change Subject without to change notice. without notice.


DS 201POrdering Code53Ordering code DS 201PDS 201P- - - - - - - - - -Pressuregaugeabsolute7 8 77 8 8Input[bar]60 6 0 0 2100 1 0 0 3160 1 6 0 3250 2 5 0 3400customer4 0 0 39 9 9 9 consultAnalogue outputwithout4 … 20 mA / 2-wire0 … 10 V / 3-wire4 … 20 mA / 3-wire, adjustable1Intrinsic safety 4 … 20 mA / 2-wirecustomer0137E9 consultContact1, 21 contact1, 22 contacts4 contacts124Accuracy0.5 %customer59 consultElectrical connectionMale plug M12x1 (5-pin) /plastic versionN 0 13Male plug M12x1 (8-pin) /plastic versionM 5 0Male plug M12x1 (5-pin) /metal versionN 1 12Male and female plug ISO 4400Male plug Binder series 723 (5-pin)4Cable outlet incl. cablecustomer1 0 02 0 0T A 09 9 9 consultMechanical connectionG1/2" DIN 3852 withflush diaphragmZ 0 0G3/4" DIN 3852 withflush diaphragmZ 3 0G1" DIN 3852 withflush diaphragmZ 3 1G 1/2" DIN 3852 with rad. o-ringand flush diaphragmZ 6 1customer9 9 9 consultDiaphragmStainless steel 1.4435 (316L)customer19SealsFKM 15FFKMcustomer79 consultFilling FluidsSilicon oilfood compatible oilcustomer129 consultSpecial versionstandard6with cooling element up to 300°Ccustomer0 0 02 0 09 9 9 consult1 with Ex version max. 1 contact is possible2 with connector ISO 4400 and output 2-wire version only max. 1 contact possible; with 3-wire version no contact possible3 4 contacts and M12x1, 8-pin only possible in combination and together with 4 ... 20 mA/3-wire; 0 ... 10 V/3-wire on request4 standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 … 70 °C), others on request5 possible for nominal pressure ranges P N ≤ 100 bar6 cooling element up to 300°C not possible for pressure range P N > 160 barThis document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet.Subject to change without notice.13.02.2013This dokument contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.www.bdsensors.com


54pressure switch with displayDS 217Pressure Switchwith weldedStainless Steel SensorCharacteristics:► accuracy according to IEC 60770:0.5 % FSO► nominal pressure rangesfrom 0 … 6 bar up to 0 … 600 bar► 1 analogue output and up to2 contacts► display and housing rotatable► suitable for oxygen applicationsTechnical DataInput pressure rangeNominal pressure gauge [bar] 6 10 16 25 40 60 100 160 250 400 600Overpressure (static) [bar] 14 35 35 70 140 140 350 350 700 1 200 1 200Burst pressure ≥ [bar] 28 70 70 140 280 280 700 700 1 400 1 500 1 500Vacuum resistanceunlimitedContactstandard1 PNP contactoptionmax. 2 independent PNP contact; 1 analogue outputSwitching currentstandard: contact rating max. 500 mA, short-circuit resistantAccuracy of switching points 1 ≤ ± 1.5 % FSORepeatability≤ ± 0.5 % FSOSwitching frequencymax. 10 HzSwitching cycles > 100 x 10 6Delay time0 ... 100 secAnalogue output (optionally) / Supply3-wire current signal 4 ... 20 mA / V S = 24 V DC ± 10 %Accuracy 1≤ ± 0.5 % FSOPermissible load 3-wire: R max = 500 ΩInfluence effects supply: 0.05 % FSO / 10 V load: 0.05 % FSO / kΩMeasuring rate10 Hz1 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)Thermal effects (Offset and Span) / Permissible temperaturesThermal error ≤ ± 0.5 % FSO / 10 K in compensated range -25 ... 85 °CPermissible temperatures medium: -25 ... 125 °C electronics / environment: -25 ... 85 °C storage: -40 ... 85 °CElectrical protectionShort-circuit protectionpermanentReverse polarity protection no damage, but also no funcitionElectromagnetic compatibility emission and immunity according to EN 61326BD SENSORS www.bdsensors.com GmbHBD-Sensors-Straße 1 Telefon +49 (0) 92 35 / 98 11- 0 www.bdsensors.com


DS 217DS 217OEM Pressure SwitchTechnical DataTechnical Data55Mechanical stabilityVibration 10 g (25 … 2000 Hz) according to DIN EN 60068-2-6Shock 500 g / 1 msec according to DIN EN 60068-2-27MaterialsPressure port / Housing stainless steel 1.4571 (316 Ti) / stainless steel 1.4301 (304)Display housingPA 6.6, polycarbonateSeal sensornone (welded)Diaphragmstainless steel 1.4542 (17-4PH)Media wetted partspressure port, seal pressure port, diaphragmMiscellaneousWeightapprox. 160 gDisplay 4-digit, red LED display, digit height 7 mm, digit width 4.85 mm (angle 10°); range of indication -1999... +9999; accuracy 0.1% ± 1 digit; digital damping 0.3 … 30 sec (programmable);measured value update 0.0 … 10 sec (programmable)Long term stability≤ ± 0.3 % FSO / year at reference conditionsCE-conformity EMC Directive: 2004/108/EC Pressure Equipment Directive: 97/23/EC (module A) 22 This directive is only valid for devices with maximum permissible overpressure > 200 bar.Wiring diagrams3-wire-system (current)pSupply +VSSupply –Signal +ARLIContact 1Contact 2RLPin configurationElectrical connectionssupply +supply –signal + (only for 3-wire)contact 1contact 2shieldConnections (dimensions in mm) G1/2" EN 837Mechanical connections - optionalG1/4" EN 8371/4" NPTM12x1 (5-pin) plastic13245via pressure portElectronical connectionsM12x1 (5-pin)This data sheet contains product specification, properties are not guaranteed. Subject to change without notice.This document contains product specifications; properties are not guaranteed. Subject to change without notice.www.bdsensors.comDS217_E_311012


56DS 217Ordering CodeOrdering code DS 217DS 217- - - - - - - -Pressuregauge 7 8 PInput[bar]6 6 0 0 110 1 0 0 216 1 6 0 225 2 5 0 240 4 0 0 260 6 0 0 2100 1 0 0 3160 1 6 0 3250 2 5 0 3400 4 0 0 3600customer6 0 0 39 9 9 9 consultAnalogue outputwithout analogue output4 … 20 mA / 3-wirecustomer079 consultContact1 contact2 contacts12Accuracy [IEC 60770]standard 0.5 % 5customer9 consultElectrical connectionMale plug M12x1 (5-pin) /plastic versionN 0 1customer9 9 9 consultMechanical connectionG 1/2" EN8372 0 0 2G1/4" EN 8374 0 0 21/4" NPTN 4 0 2customer9 9 9 9 consultSpecial versionstandardoxygen applicationcustomer0 0 00 0 79 9 9 consult21.01.2013This ordering code contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet.Subject to change without notice.www.bdsensors.com


pressure switch with display57DS 230Electronic OEMPressure SwitchApplications:►►pneumaticspumps and hydraulic machinesCharacteristics:►►►►►nominal pressure ranges from0 … 2 bar up to 0 … 400 bardisplay and housing rotatableup to 2 contactsconfigurable via displayoptional: analogue outputTechnical DataInput pressure rangeNominal pressure gauge [bar] 2 5 10 20 50 100 250 400Overpressure [bar] 4 10 20 40 100 200 400 600Burst pressure [bar] 7 15 35 70 150 250 450 650SupplySupply voltage V S 24 V DC ±10 %Current consumption< 40 mA (without analogue output and without contacts)Output signalNumber, type standard: 1 PNP contactoptional: max. 2 independent PNP contacts; 1 analogue outputContact (Standard)Switching currentstandard: contact rating max. 500 mA, short-circuit resistantAccuracy of contacts 1≤ ± 1.5 % FSO BFSLRepeatability 1≤ ± 0.5 % FSO BFSLSwitching frequencymax. 100 HzSwitching cycles > 100 x 10 6FunctionsHysteresis- / Compare moden/o / n/cDelay time0 ... 99.99 secAnalogue output (optionally)Signal output4 ... 20 mA (3-wire)Linearity, hysteresis,repeatability≤ ± 0.5 % FSO BFSLCalibration accuracy≤ ± 1 % FSO BFSLPermissible loadR max = 500 ΩResponse time< 10 msec1 depending on nominal pressure rangeThermal effects (Offset and Span) / Permissible temperaturesThermal error for offset ≤ ± 0.5 % FSO / 10 K in compensated range -25 ... 85 °CPermissible temperatures medium: -25 ... 125 °C electronics / environment: -25 ... 85 °C storage: -40 ... 85 °CBD www.bdsensors.comSENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.com


58DS 230Technical DataDS 230Electronic OEM Pressure SwitchTechnical DataElectrical protectionShort-circuit protectionpermanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 61326MaterialsPressure port stainless steel 1.4301Housing stainless steel 1.4301Display housingPA 6.6, PolycarbonateSeals (media wetted) FKM others on requestDiaphragm ceramic Al 2O 3 96 %TouchpadpolyesterMedia wetted partspressure port, seals, diaphragmMiscellaneousDisplay4-digit, red LED display, digit size 7 mm, digit width 4.85 mm (angle 10 °); range ofindication -1999 ... 9999; accuracy 0.3 % ±1 digit; digital damping 0.3 … 30 sec(programmable); measured value update 0.0 … 10 sec (programmable)Weightapprox. 180 gInstallation positionanyIngress protection IP 65CE-conformity EMC Directive: 2004/108/EC Pressure Equipment Directive: 97/23/EC (module A) 22 This directive is only valid for devices with maximum permissible overpressure > 200 barWiring diagrampSupply +VSSupply –Signal +ARLIContact 1Contact 2RLPin configurationElectrical connectionDimensions (in mm)Supply +Supply –Signal +Contact 1Contact 2Shield G1/4" DIN 3852M12x1 (5-pin), plastic13245via pressure port 1/4" NPTThis data sheet contains product specification, properties are not guaranteed. Subject to change without notice.This document contains product specifications; properties are not guaranteed. Subject to change without notice.www.bdsensors.comDS400_E_311012


DS 230Ordering Code59Ordering code DS 230DS 230- - - - - - - -Pressuregauge 7 8 RInput[bar]2 2 0 0 15 5 0 0 110 1 0 0 220 2 0 0 250 5 0 0 2100 1 0 0 3250 2 5 0 3400customer4 0 0 39 9 9 9 consultAnalogue outputwithout analogue output4 … 20 mA / 3-wirecustomer079 consultContact1 contact2 contacts12Calibration accuracy2 %customerG9 consultElectrical connectionMale plug M12x1 (5-pin) /plastic versionN 0 1customer9 9 9 consultMechanical connectionG1/4" DIN 38521/4" NPTcustomer3 0 0N 4 09 9 9 consultSealsFKMcustomer19 consultSpecial versionstandardcustomer0 0 09 9 9 consult21.01.2013This ordering code contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet.Subject to change without notice.www.bdsensors.com


60pressure switch without displayDS 4Electronic OEM PressureSwitch PneumaticsApplications:►►PneumaticsVacuum technologyCharacteristics:►►►►nominal pressure ranges from0 ... 1 bar up to 0 ... 10 baralso -1 ... 0 bar1 or 2 contactscompact designconfigurable via PC orprogramming device P6Technical DataInput pressure rangeNominal pressure gauge [bar] -1 ... 0 1 3.5 10Overpressure [bar] 2 2 7 13SupplySupply voltage V S12 ... 30 V DCCurrent consumptionmax. 14 mA (without contacts)Output signalContact 1Number standard: 1 optional: 2TypePNPSwitching performancemax. 300 mA, short-circuit proofAccuracy of contacts 2≤ ± 1 % FSORepeatability≤ ± 0.2 % FSOStatus indication SP 1: green SP 2: yellowSwitching function 3 standard: n/o optional: n/cSwitching mode 3 standard: hysteresis mode optional: window modeSwitch on point 3standard: factory setting 80 % FSOothers: specify on order; adjustable range 0 ... 100 % FSOSwitch off point 3standard: factory setting 75 % FSOothers: specify on order; adjustable range 0 ... 100 % FSOSwitch on / switch off delay 3 standard: offothers: specify on order, adjustable range from 10 msec up to 90 sec (step 10 msec)Switching frequency200 Hz (without switching delay)Switching cycles > 100 x 10 6Analogue output 1 (optionally)Analogue output1 ... 5 V / 3-wireAccuracyIEC 60770 3 : ≤ ± 2 % FSOPermissible loadR min = 10 kΩ1 with optional analogue output max. 1 contact possible2 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)3 Parameters can be programmed by customer either with the programming kit CIS 680 / CIS 681 or with the programming device P6(available as accessories).BD www.bdsensors.comSENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.com


DS 4Technical DataDS 4Electronic OEM Pressure SwitchTechnical Data61Thermal effects (Offset and Span) / Permissible temperaturesTolerance band ≤ ± 2 % FSO in compensated range 0 ... 50 °CTC, average ≤ ± 0.4 % FSO / 10 K in compensated range 0 ... 50 °CPermissible temperatures medium / electronics / environment: -25 ... 85 °C storage: -40 ... 85 °CElectrical protectionShort-circuit protectionpermanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 61326Mechanical stabilityVibration10 g RMS (20 ... 2000 Hz)Shock100 g / 11 msecMaterialsPressure portaluminiumHousingPA 6.6 blackSeal (media wetted)NBRSensorsilicon, RTVMedia wetted partspressure port, seal, sensorMiscellaneousMediacompressed air, non-aggressive gasesWeightapprox. 25 bis 35 gInstallation positionanyIngress protection IP 54CE-conformityEMC Directive: 2004/108/ECWiring diagrams1 contact (without analogue output) 2 contacts (without analogue output) 1 contact (with analogue output)supply +supply +supply +VSVSVSsupply –contactRsupply –contact 1contact 2RRsupply –signal +contactRPin configurationElectrical connectionDimensions (in mm)Supply +Supply –Signal +Contact 1Contact 2M8x1 (4-pin)1 contactview X13-4-M8x1 (4-pin)2 contacts13-42Mechanical connections (view X)G1/8" internal threadM5 internal threadM8x1 (4-pin)1 contact,1 analogue output1324-G1/8-6.5 deepM5-7 deepThis data sheet contains product specification, properties are not guaranteed. Subject to change without notice.This document contains product specifications; properties are not guaranteed. Subject to change without notice.www.bdsensors.comDS4_E_311012


62DS 4Ordering CodeOrdering code DS 4DS 4- - - - - - - -Pressuregauge 6 8 0Input[bar]1.0 1 0 0 13.5 3 5 0 110 1 0 0 2-1 … 0customerX 1 0 29 9 9 9 consultNumber of contacts1 contact12 contacts12Analogue outputwithout analogue output11 … 5 V / 3-wire0CElectrical connectionM8x1 (4-pin)customerQ 0 09 9 9 consultMechanical connectionG1/8" internal thread2M5 internal thread with slot for O-ringcustomerQ 0 0R 0 09 9 9 consultSealsNBRcustomer59 consultSetting code3BD SENSORS standard3setting according to customer0 0 09 9 9 consultSpecial versionstandardcustomer0 0 09 9 9 consult1 with optional analogue output max. 1 contact possible2 suitable for flange installation3 Parameters can be programmed by customer either with the programming kit CIS 680 / CIS 681 or with the programming device P6 (available as accessories).This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet.Subject to change without notice.10.01.2013This ordering code contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.www.bdsensors.com


pressure switch without display63DS 6ElectronicOEM Pressure SwitchApplications:►►mechanical enginering / hydraulicsmeasuring, control andprocess technologyCharacteristics:►►►►nominal pressure ranges from0 … 2 bar up to 0 … 400 bar1 or 2 contactsconfigurable via PC orprogramming device P6optional:- oil- and fat free version- oxygen applicationTechnical DataInput pressure rangeNominal pressure gauge [bar] 2 5 10 20 50 100 200 400Nominal pressure abs. [bar] 2 5 10 20 50 100 200 400Overpressure [bar] 7 12 25 50 120 250 400 600SupplySupply voltage V S12 ... 30 V DCCurrent consumptionmax. 14 mA (without contacts)ContactsNumber standard: 1 optional: 2TypePNPSwitching performancemax. 300 mA, short-circuit proofAccuracy of contactsIEC 60770: ≤ ±1 % FSORepeatability≤ ± 0.2 % FSOMinimum hysteresis of contacts ≤ ± 0.5 % FSOStatus indication SP 1: green SP 2: yellowSwitching function 1 standard: n/o optional: n/cSwitching mode 1 standard: hysteresis mode optional: window modeSwitch on point 1 standard: factory setting 80 % FSOothers: specify on order; adjustable range 5 ... 100 % FSOSwitch off point 1 standard: factory setting 75 % FSOothers: specify on order; adjustable range 5 ... 100 % FSOSwitch on / switch off delay 1 standard: offothers: specify on order, adjustable range from 10 msec up to 90 sec (step 10 msec)Switching frequency200 Hz (without switching delay)Switching cycles > 100 x 10 61 Parameters can be programmed by customer either with the programming kit CIS 685 / CIS 686 or with the programming device P6(available as accessories).Thermal effects (Offset and Span) / Permissible temperaturesThermal error ≤ ± 0.3 % FSO / 10 K in compensated range -25 ... 85 °CPermissible temperatures medium / electronics / environment: -25 ... 85 °C storage: -40 ... 85 °CBDwww.bdsensors.comSENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.com


64DS 6Technical DataDS 6Electronic OEM Pressure SwitchTechnical DataElectrical protectionShort-circuit protectionpermanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 61326Mechanical stabilityVibration10 g RMS (20 ... 2000 Hz)Shock100 g / 11 msecMaterialsPressure port stainless steel 1.4305Housingstainless steel 1.4305, POM blackSeals (media wetted) Standard: FKM optional: EPDM, NBRDiaphragm ceramic Al 2O 3 96 %Media wetted partspressure port, seals, diaphragmMiscellaneousOption oxygen application for P N ≤ 15 bar: O-ring in 70 EPDM 281 (with BAM-approval); permissible maximum values are15 bar / 60° C and 10 bar / 90° Cfor P N ≤ 25 bar: O-ring in FKM Vi 567 (with BAM-approval); permissible maximum values are25 bar / 150° CWeightapprox. 90 gInstallation positionanyIngress protection IP 67CE-conformity EMC Directive: 2004/108/EC Pressure Equipment Directive: 97/23/EC (module A) 22 This directive is only valid for devices with maximum permissible overpressure > 200 barWiring diagrams1 contact 2 contactssupply +supply +VSVSVsupply –contactRVsupply –contact 1contact 2RRPin configurationElectrical connectionDimensions (in mm)Supply +Supply –Contact 1Contact 2ShieldG1/4" DIN 3852M12x1 (5-pin)1345plug housingThis data sheet contains product specification, properties are not guaranteed. Subject to change without notice.This document contains product specifications; properties are not guaranteed. Subject to change without notice.www.bdsensors.comDS6_E_250213


DS 6Ordering Code65Ordering code DS 6DS 6- - - - - - - -PressureInputNumber of contacts1 contact2 contactsAnalogue outputwithout analogue outputElectrical connectionM12x1 (5-pin)customerMechanical connectionG1/4" DIN 3852customerSealsSetting codeBD SENSORS standardsetting according to customerSpecial versionstandardoxygen applicationoil and grease freecustomergaugeabsolute6 8 56 8 6[bar]2 2 0 0 15 5 0 0 110 1 0 0 220 2 0 0 250 5 0 0 2100 1 0 0 3200 2 0 0 3400 4 0 0 3customer9 9 9 9 consult120N 1 19 9 9 consult3 0 09 9 9 consultFKM 1EPDM 3NBRcustomer59 consult1121 Parameters can be programmed by customer either with the programming kit CIS 685 / CIS 686 or with the programming device P6 (available as accessories).2 oxygen application with FKM-seal up to 25 bar or with EPDM-seal up to 15 bar possible, flush version on requestThis document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet.Subject to change without notice.0 0 09 9 9 consult0 0 00 0 70 0 89 9 9 consult25.02.2013This dokument contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.www.bdsensors.com


664 ADVANTAGEScompetenceIndustrial pressure measurement technologyfrom 0.1 mbar up to 6000 barPrice / performancepressure measurement at the highest level> > pressure transmitters, electronic pressureswitches or hydrostatic level probes> > OEM or high-end products> > standard products or customized solutions<strong>BD|SENSORS</strong> has the right pressure measuring deviceat the right price.The concentration on electronic pressure transmitter has ledto extraordinary efficiency and economical pricing.<strong>BD|SENSORS</strong> is certain to be one of the most economicalsuppliers on the world market, given equal technical andcommercial conditions.RELIABILITYprojectable delivery times and strictobservance of deadlinesFlexibilitYWe have special solutions for your individualrequirement.Short delivery times and firm deadlines, even for specialdesigns, make <strong>BD|SENSORS</strong> a reliable partner for ourcustomers.We solve your problem in industrial pressure measurementquickly and economically, not only with large-scaleproduction lines, but also for smaller requirements.<strong>BD|SENSORS</strong> reduces the level of your stock-keeping andincreases your profitability.<strong>BD|SENSORS</strong> is especially flexible when technical supportand quick assistance are required in service case as wellas for rush orders.www.bdsensors.com


67INDUSTRIESMEDIAplant and machine engineeringsewagechemical and biochemical industryaggressive mediaenergy industrycoloursrenewable energygasessemiconducter industry /cleanroom technologyHVACfuels and oilspasty and viscous mediahydraulicsoxygenrefrigerationwatercalibration techniqueslaboratory techniquesmedical technologyfood and beveragevehicles and mobile hydraulicsoil and gas industrypharmaceutical industrymarine / shipbuilding / offshoreheavy industryenvironmental industrypackaging and paper industry


Distribution worldwideHeadquarter OF <strong>BD|SENSORS</strong> GrOUPBD | SENSORS GmbHBD-Sensors-Straße 195199 ThiersteinGermanyTel.: +49 9235 9811-0Fax: +49 9235 9811-11www.bdsensors.deinfo@bdsensors.deDISTRIBUTION EaSTERN EUROPEBD | SENSORS s.r.o.Hradišt’ská 817687 08 BuchloviceCZech RePuBlicTel.: +420 572 411-011Fax: +420 572 411-497www.bdsensors.czsale@bdsensors.czStatus 02/2013Technical changes reserved.