<strong>Compact</strong> <strong>NSX</strong>,more than a breakerit’s a breakthrough<strong>Compact</strong> <strong>NSX</strong><strong>100</strong>-630 A


Intelligent outlookToday, we are living in an increasingly booming andfast changing world where energy is key. Morethan ever, the current situation compels eachand everyone to achieve more while using lessresources.As Global specialist in energy management,<strong>Schneider</strong> <strong>Electric</strong> innovates its new MCCB<strong>Compact</strong> <strong>NSX</strong> which is the optimum measurementand communication solution that meet your energyefficiency challenges through optimized energyconsumption, increased energy availability andimproved installation management.For the first time, you can monitor both energyand power, offering new performance in aremarkably compact device.Our main aim is to make energy safe, reliable andefficient.


<strong>Compact</strong> <strong>NSX</strong>more than a breakerTraditional breaker ...@ Switch on/off the circuit@ Protection against:> overload,> short circuit,> earth leakage.@ IsolationThe breakthrough ...@ Combine safety & performance:> Roto active technology,> New breaking capacities.@ Monitoring and Management> Integrated monitoring for all electricalparameters (I, V, E THD, ... etc),> Accessibility of Information.@ Better continuity of service> Improved discrimination,> Preventive maintenance.@ Added simplicity> Torque limiting screws,> Green “ ready “ led.@ Ease of communication


Combine safetyand performance<strong>Compact</strong> <strong>NSX</strong> is innovative – it incorporates monitoring and communicationfunctions, from 40 amps upward, combined with perfect protection.23new patents pendingconfirm the innovativecharacter of <strong>Compact</strong> <strong>NSX</strong>Expert technologyA roto-active contact breaking principle provides better limitationand endurance performance:@ very high breaking capacity in a very small device,@ exceptional fault current limitation for extended system life.Reduced installation costsAchieve up to 30% savings:@ total discrimination is ensured particulary in the case ofminiature circuit breakers for considerable savings at the time ofinstallation,@ smaller devices mean more economical switchboardsfor a significant impact on overall cost of installation –no need for over-calibration.NS400<strong>NSX</strong>250New breaking capacitiesNew performance levels improve application targeting:@ 25kA – standard low short-circuit level applications,e.g., in service businesses,@ 36-50kA – standard applications(industrial plants, buildings and hospitals),@ 70-<strong>100</strong>kA – high performance at controlled cost,@ 150kA – demanding applications (marine).Enhanced protection for motors<strong>Compact</strong> <strong>NSX</strong> meets the requirements of IEC 60947-4-1standards for protection of motors:@ well adapted to motor-starting solutionsup to 315kW at 400V, providing protection againstshort circuits, overloads, phase unbalance and loss,@ set up additional protection systems for starting and brakingwith the motor running, reverse braking, jogging or reversingin complete safety,@ used in conjonction with a <strong>Schneider</strong> <strong>Electric</strong> contactor;<strong>Compact</strong> <strong>NSX</strong> complies with the requirements of so-calledtype 2 coordination.NS160(<strong>100</strong> A)<strong>NSX</strong><strong>100</strong>Multi 9


Monitoring & management<strong>Compact</strong> <strong>NSX</strong> is a single device, which contains a monitoring unitto control energy consumption and power.Integrated monitoring@ A Micrologic electronic tripping device with next-generation sensors:> an "iron sensor for the power supply to the electronics,> an "air" sensor (Rogowski coils) for the measurement part.@ The originality lies in how <strong>Compact</strong> <strong>NSX</strong> measures, processes anddisplays data, either directly on screen, on the switchboard front panel,or via a monitoring system.- 10 %Monitoring consumptioncan help reduce energycosts by as much as 10%.Accessibility of informationTo keep costs under control and ensure service continuity,relevant information must be available in real time:@ a kilowatt-hour meter helps optimise costs and their allocation,@ harmonic distortion rate shows the quality of electrical supply,@ alarm notification secures operational control and maintenanceplanning,@ event logs and tables, activated continuously, ensure the installedequipment base operates correctly, so energy efficiency is maximized.Installation supervisionUsed in conjunction with PowerLogic monitoring software,<strong>Compact</strong> <strong>NSX</strong> provides users with a set of parameters and toolsto make it easy to monitor installations.ASICElectronics (ASIC),independent ofmeasurement, manageprotection functions.The high degree ofintegration in electronicsguarantees protectionagainst conducted orradiated interference.


Better service continuity<strong>Compact</strong> <strong>NSX</strong> makes discrimination its main advantage in minimizing the impactof short circuits, ensuring service continuity for installations.Total discrimination@ With 30 years of experience and as an expert in discrimination,users can be sure of service continuity.Downstream circuit breaker trips as close as possible to the fault,so upstream circuit breaker is not overloaded.<strong>100</strong> %service continuityService continuityAdding an SDX module remotes the trip or alarm condition of compact<strong>NSX</strong> breaker, ensuring total service continuity:@ The SDX module indicates tripping due to overload fault,@ The module can be assigned to overload pre-alarm function,@ The module indicates ground fault trip.Preventive maintenanceMaintenance indicators provide information on the number of operations,level of wear on contacts and total load rates. Maintenance is nowpreventive, avoiding faults.Direct access tomaintenance indicators


Added simplicity<strong>Compact</strong> <strong>NSX</strong> takes the principles of easy installation and use which made itspredecessor so successful to a higher level.Simple in design@ Installers mount and wire <strong>Compact</strong> <strong>NSX</strong> in the same way as <strong>Compact</strong>NS, which makes engineering for a retrofit or extension simple.@ Integration in help software, for parameter settings and switchboardinstallation, eases design.Simple to install@ A Limited Torque Screw (LTS) system ensures proper installationof the tripping device, for added flexibility.@ A transparent sealed flap protects access to tripping device switchesand prevents settings from being changed.@ New electrical control adjustment also has a transparent sealable coverto prevent it from being operated accidentally.Simple to use@ Users customise alarms for all parameters, assign them to indicatorlights, choose display priorities, and configure time delay thresholds andmodes.@ Continuously-activated event logs and tables, a wealth of information,enable users to ensure that the installed equipment base operates correctly,and to optimize settings.65%time savings in installationcompared with a classicmonitoring solution.The green "Ready" LEDflashes to show that allis well.LTS installation systemTransparentprotective cover


Ease of communicationPre-wired connectivity and plug – and – play interface modules allows easyintegration with communication networking.BSCM ModuleCommunication states and orders.Modbus IFM interfaceInterface with Modbus network.FDM 121 switch board display unit@ Direct access to essential information.@ Uses the sensors and processing capacity of the Micrologic.@ No special software or settings is required.<strong>NSX</strong> “Plug and play “ cord cablesCommunication with switchboard display unit and/or the Modbus interface without parameter setting.ModbusIFMinterfaceModbus<strong>NSX</strong> cordFDM121switchboard display unit<strong>Compact</strong> <strong>NSX</strong>+BSCM Module


<strong>Compact</strong> <strong>NSX</strong>,an optimum compitabilitywith Ecodial V 3.4Providing more expertise and time saving in your electrical design installations,<strong>Schneider</strong> <strong>Electric</strong> innovates special adapted software helping you to design solutionsthat meet the different business requirements.Ecodial V 3.4 is fully adapted to the local marketThe new version of the Ecodial is adapted for the Egyptian market & complies with the latest electrical standards.The selection of the electrical products & cables are complying with the local market needs. Cascading and discriminationcalculations are based on the available sizes & ratings in the South African market.Ecodial V 3.4 new functionalities@ New ergonomics@ A cable summary is at your disposal@ The report now includes power sum results@ Improvement of the motor starter management@ Curve direct evolution:> save the tripping-curve and settings as an .rtf file> display the tripping-curves of thermal relays@ You can choose variable speed drives “manually”@ Ecodial V3.4 takes into account the tuning frequencies of detuning reactors as part of compensation<strong>Compact</strong> <strong>NSX</strong>Ecodial softwareMaximum control &energy measurement; Ecodial V 3.4 ... your efficient assistant for electrical installations.


<strong>Compact</strong> <strong>NSX</strong>CharacteristicsCommon characteristicsRated voltagesInsulation voltage (V) Ui 800Impulse withstand voltage (kV) Uimp 8Operational voltage (V) Ue AC 50/60 Hz 690Suitability for isolation IEC/EN 60947-3 yesUtilisation categoryAPollution degree IEC 60664-1 3ControlManual With toggle ■With direct or extended rotary handle■<strong>Electric</strong>al With remote control ■VersionsFixed■Withdrawable Plug-in base ■Chassis■Circuit breakersBreaking-capacity levels<strong>Electric</strong>al characteristics as per CEI/IEC 60947-2Rated current (A) In 40 °CNumber of polesBreaking capacity (kA rms)Service breaking capacity (kA rms)lcu AC 50/60 Hz220/240 V380/415 V440 V500 V525 V660/690 Vlcs AC 50/60 Hz 220/240 V380/415 V440 V500 V525 V660/690 VDurability (C-O cycles)Mechanical<strong>Electric</strong>al 440 V In/2In690 V In/2InCharacteristics as per Nema AB1Breaking capacity (kA rms) AC 50/60 Hz 240 V480 V600 VCharacteristics as per UL 508Breaking capacity (kA rms) AC 50/60 Hz 240 V480 V600 VType of protection and applicationsMA magnetic TM-D Micrologic 2 Micrologic 5 / 6 A or Ethermal-magneticelectronic5 A or E 6 A or E 6 E-Mclasse■ Distribution and motors■ Distribution■ Generators■ Distribution■ Service connection(public distribution)■ Generators■ Motors (I only)■ Motors■ Distributionand generators■ Distributionand generators■ Motors


30A>95% T°185140120 210<strong>100</strong> 220Ir (A).7.4.3 1.2 OFFIg (x In)>30AIr Cl.NMode>95% T°400320280 470250 500Ir (A).7.4.5 .6 .8.3 .9.2 OFFIg (x In)Isd1/A 2/B 3/CIunbal tunbal Ijam tjamIgAtestOKIr Cl. Isd Iunbal tunbal Ijam tjam Ig tgModeN 1/A 2/B 3/CtgAtestOKIi=6500AIEC60947-4-1Ir 7.2IrClassIsd<strong>NSX</strong><strong>100</strong> <strong>NSX</strong>160 <strong>NSX</strong>250 <strong>NSX</strong>400 <strong>NSX</strong>630B F N H S L B F N H S L B F N H S L F N H S L F N H S L<strong>100</strong> 160 250 400 6302, 3, 4 2, 3, 4 2, 3, 4 3, 4 3, 440 85 90 <strong>100</strong> 120 150 40 85 90 <strong>100</strong> 120 150 40 85 90 <strong>100</strong> 120 150 40 85 <strong>100</strong> 120 150 40 85 <strong>100</strong> 120 15025 36 50 70 <strong>100</strong> 150 25 36 50 70 <strong>100</strong> 150 25 36 50 70 <strong>100</strong> 150 36 50 70 <strong>100</strong> 150 36 50 70 <strong>100</strong> 15020 35 50 65 90 130 20 35 50 65 90 130 20 35 50 65 90 130 30 42 65 90 130 30 42 65 90 13015 25 36 50 65 70 15 30 36 50 65 70 15 30 36 50 65 70 25 30 50 65 70 25 30 50 65 70- 22 35 35 40 50 - 22 35 35 40 50 - 22 35 35 40 50 20 22 35 40 50 20 22 35 40 50- 8 10 10 15 20 - 8 10 10 15 20 - 8 10 10 15 20 10 10 20 25 35 10 10 20 25 3540 85 90 <strong>100</strong> 120 150 40 85 90 <strong>100</strong> 120 150 40 85 90 <strong>100</strong> 120 150 40 85 <strong>100</strong> 120 150 40 85 <strong>100</strong> 120 15025 36 50 70 <strong>100</strong> 150 25 36 50 70 <strong>100</strong> 150 25 36 50 70 <strong>100</strong> 150 36 50 70 <strong>100</strong> 150 36 50 70 <strong>100</strong> 15020 35 50 65 90 130 20 35 50 65 90 130 20 35 50 65 90 130 30 42 65 90 130 30 42 65 90 1307,5 12,5 36 50 65 70 15 30 36 50 65 70 15 30 36 50 65 70 25 30 50 65 70 25 30 50 65 70- 11 35 35 40 50 - 22 35 35 40 50 - 22 35 35 40 50 10 11 11 12 12 10 11 11 12 12- 4 10 10 15 20 - 8 10 10 15 20 - 8 10 10 15 20 10 10 10 12 12 10 10 10 12 1250000 40000 20000 15000 1500050000 20000 20000 12000 800030000 <strong>100</strong>00 <strong>100</strong>00 6000 400020000 15000 <strong>100</strong>00 6000 6000<strong>100</strong>00 7500 5000 3000 200040 85 90 <strong>100</strong> 120 150 40 85 90 <strong>100</strong> 120 150 40 85 90 <strong>100</strong> 120 150 40 85 <strong>100</strong> 120 150 40 85 <strong>100</strong> 120 15020 35 50 65 90 130 20 35 50 65 90 130 20 35 50 65 90 130 30 42 65 90 130 30 42 65 90 130- 8 20 35 40 50 - 20 20 35 40 50 - 20 20 35 40 50 - 20 35 40 50 - 20 35 40 50- 85 85 85 - - - 85 85 85 - - - 85 85 85 - - 85 85 85 - - 85 85 85 - -- 25 50 65 - - - 35 50 65 - - - 35 50 65 - - 35 50 65 - - 35 50 65 - -- 10 10 10 - - - 10 10 10 - - - 15 15 15 - - 20 20 20 - - 20 20 20 - -Circuit breakers and trip unitsCOMPACT <strong>NSX</strong> <strong>100</strong>/160/250ReadyAlarm155 170 200.5 .6 .86.2 E-MMicrologic220MA Distribution and motorsCOMPACT <strong>NSX</strong> 400/600TM-D DistributionTM-G Generators2.2 Distribution2.2-AB Service connection(public distribution)2.2-G Generators2.2-M Motors5.2 A Distribution andgenerators5.2 E Distribution andgenerators6.2 A Distributionand generators6.2 E Distributionand generators6.2 E-M MotorsReadyAlarmMicrologic 6.3 E-M350 380 4405001.3-M Distribution and motors2.3 Distribution2.3-AB Service connection(public distribution)1.3-M Motors (I only)2.3-M Motors5.3 A Distribution andgenerators5.3 E Distribution andgenerators6.3 A Distributionand generators6.3 E Distributionand generators6.3 E-M Motors


<strong>Schneider</strong> <strong>Electric</strong> South Africa (Pty) LtdHead Office1 River View Office Park,Janadel Avenue, Halfway Gardens,Midrand, 1685Tel.: +27 (0)11 254 6400http://www.schneider-electric.co.zaAs standard specificationsand designs change fromtime to time, please ask forconfirmation of the informationgiven in this publication.SEE 98039 / E