<strong>EMI</strong> <strong>Power</strong><strong>Filters</strong>Signal & <strong>Power</strong> Integrity Group<strong>Spectrum</strong> <strong>Control</strong> <strong>EMI</strong> filtered power products preventunwanted interference from entering your system, aswell as eliminate emissions that can contaminate theAC power grid. Our standard and custom productsare available in a wide range of AC/DC current andvoltage ratings to address <strong>EMI</strong> filtering for high currentapplications. All <strong>Spectrum</strong> power products aredesigned to meet global EMC emissions regulations.A<strong>Control</strong> ProductsSystems Company&<strong>Spectrum</strong> <strong>Control</strong> is committed to providing anintegrated approach to EMC problem solving by offeringcustomers consulting, diagnostic testing, design andmanufacturing services. As a fully integrated manufacturer,<strong>Spectrum</strong> <strong>Control</strong> is able to respond to short lead timerequests for new prototypes and variations to standardproducts. This enables us to provide the most costeffectivesolution that satisfies both your performanceand budgetary needs.In addition, our family of power products providelow cost solutions to <strong>EMI</strong> challenges, helping youlower inventories and increase production assemblyefficiency.<strong>Spectrum</strong> <strong>Control</strong> power products are used ina variety of industries worldwide, including telecommunications,computers and peripherals, medical,aerospace, military, power supplies, appliancesand industrial controls.CERTIFIED2


<strong>Spectrum</strong> <strong>Control</strong> Inc...PageSingle Line <strong>Filters</strong>• DC Single Line Feed-thru Series• DC Single Line Pi Series• AC Single Line Feed-thru Series• AC Single Line Pi Series• Single Line Feed-thru <strong>Filters</strong>12 - 22High Current FilteredTerminal Blocks• High Current FilteredTerminal Blocks23<strong>Power</strong> Entry ModulesBolt-in Rear TerminalsBolt-in Right Angle TerminalsHigh Frequency AttenuationSnap-in With Wire LeadsBolt-in With Wire LeadsSnap-in Mount• Fused Filtered<strong>Power</strong> Entry Modules• Switched & Fused Filtered<strong>Power</strong> Entry Modules• Switched & Fused Filtered<strong>Power</strong> Entry Modules ForEuropean Market24 - 51PCB <strong>Power</strong> <strong>Filters</strong>• Miniature PrintedCircuit Boards• <strong>Power</strong> Entry Modules Bolt-inRight Angle Terminals• <strong>Power</strong> Entry ModulesHigh FrequencyAttenuation Bolt-in• PCB <strong>Power</strong> <strong>Filters</strong> MiniaturePrinted Circuit Boards52 - 59<strong>Power</strong> Line <strong>Filters</strong>• Appliance <strong>Filters</strong>• Single Stage• Single Stage Wire Leads• Single Stage Wire Leads forMedical Purpose Applications• Single Stage - Higher Current• DC - Higher Current• DC - Single Stage• Dual Stage• Three Phase - LowCurrent/High Performance• Three Phase• Three Phase - High Performance60 - 97Military/AerospaceMultisection <strong>Filters</strong>• Military/AerospaceMultisection <strong>Filters</strong>98 - 105Custom/ApplicationSpecific <strong>Filters</strong>• Custom/ApplicationSpecific <strong>Filters</strong>106 - 109Appendix• Part Number Index• Design Inquiry Form• www.spectrumcontrol.comOnline <strong>tool</strong>s110 - 115SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-583


<strong>EMI</strong> <strong>Power</strong> <strong>Filters</strong> Selection GuideHigh CurrentFeed-thru <strong>Filters</strong>High CurrentTerminal Blocks<strong>Power</strong> EntryModules<strong>Power</strong> Entry ModulesFused/Switchedand FusedApplicationsCellular base stations, telephoneracks, high current switch modepower supplies, power amplifiersand serversCellular base stations, telecommunicationswitching networks,hi-reliability radar & transmissionsystems, industrial controls,power supplies, UPS, instrumentationand power distributionDigital equipment, personalcomputers and peripherals,measuring instruments,home appliances, monitorand display unitsDigital equipment, personalcomputers and peripherals,measuring instruments, homeappliances, monitor anddisplay unitsFeatures/Benefits■ Easy installation -Bolt-in style, surface mount■ Design flexibility -Available with single, dual,triple and quad configurations,different stud lengths,mounting brackets hardwareand <strong>EMI</strong> gasketing available.■ Performance -Ideally suited to help meetNEBS, GR1089, andEN55022■ Agency approvals -Designed to meet agencyapprovals, some selectedfilters UL 1950 recognized,CSA C22.2 certified andTÜV approved■ Custom options -Custom interfacing, contactpins, wire leads, multipleoutputs■ Environmental -Can be used in both indoorand outdoor applications■ Rugged construction -Provides protection to filteringelement; especiallyuseful for repeated in-fieldwiring changes■ Design flexibility -2 x 2 to 2 x 6 positionblocksTerminal Blocks availablewith either metric or USthreaded studs■ Performance -Filter elements providehigh insertion loss for <strong>EMI</strong>filtering of DC power linesto help meet NEBS,GR1089, and EN55022■ Agency approvals -UL recognized■ Rugged construction -Designed to perform inindustrial environments■ Design flexibility -Available in PCB mount,fast-on tab, solder lug orflying leads■ Performance -Ideally suited for productsthat must conform to FCCpart 15 regulationsMeets over-voltage of IEC664 category II andcomplies with IEC 950Metal case provides maximumisolation that optimizesperformance■ Agency approvals -UL recognized, CSA certified,TÜV approved (tested andfound to be in accordancewith VDE 0565 Part 3)■ Custom options -Value added connectors,wire leads, ring terminals■ Rugged construction -Designed to perform inindustrial environments■ Design flexibility -Bolt-in or snap-in mountingAvailable in fused orswitched and fusedversions■ Performance -Ideally suited for productsthat must conform to FCCpart 15 regulationsMeets over-voltage ofIEC 664 category II andcomplies with IEC 950Low leakage versionsavailable for medicalapplications■ Agency approvals -UL recognized, CSAcertified, TÜV approved(tested and found to bein accordance with VDE0565 Part 3)PerformanceCharacteristicsFor data sheets on theproduct you’re looking for,enter the dedicated URL■ Current ratings (max) -To 500 Amps■ Voltage ratings (max) -To 1000 VDCand to 240 VAC■ Insertion loss range -AC: 1 MHz to 1 GHzDC: 150 KHz to 10 GHz■ Temperature range --55°C to +125°C■ Capacitance -To 4.7 µFClass Y2 and Y4 availablePages 12-22■ Current ratings (max.) -Barrier strip: 60 Amps■ Voltage ratings (max.) -From 100 VDC to 250 VAC,60 Hz■ Insertion loss range -Effective insertion loss from1 MHz to 200 MHz■ Temperature range --55°C to +105°C■ Capacitance -.015 µF per line or .030 µFper pairPages 23■ Current ratings (max.) -Up to 15 Amps■ Voltage ratings (max.) -From DC to 250 VAC,60 Hz■ Insertion loss range -Effective filtering from100 KHz to 30 MHz■ Temperature range --25°C to +85°C■ Leakage current range -0.35 mA to 0.50 mA maxPages 24-41■ Current ratings (max) -2, 4 and 6 Amps■ Voltage ratings (max.) -125 VAC and 250 VAC■ Insertion loss range -Effective filtering from100 KHz to 30 MHz■ Temperature range --25°C to +85°C■ Leakage current range -0.35 mA to 0.50 mA maxfor general purpose filters0.005 mA to 0.10 mA maxfor medical filtersPages 42-51www.spectrumcontrol.com/sfilter www.spectrumcontrol.com/terblk www.spectrumcontrol.com/pem www.spectrumcontrol.com/pemfsf4SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>EMI</strong> <strong>Power</strong> <strong>Filters</strong> Selection Guide<strong>Power</strong> Line<strong>Filters</strong>Three-Phase<strong>Power</strong> Line<strong>Filters</strong>Military/AerospaceMultisection <strong>Filters</strong>Commercial CustomAssembliesApplicationsDigital equipment, personalcomputers and peripherals,measuring instruments,medical, industrial, telecommunicationsequipment, factoryautomation, UPS, vendingmachines, elevators, and switchmode power suppliesDigital equipment, industrialequipment, UPS, inverters,converters, automationequipment, computerizedindustrial washing machines,and switching power suppliesCommercial & military avionics,satellites, secured communications,ruggedized computers,radar, electronic warfare, andground/air weapon systemsTelecommunications, cellularbase stations, medicalequipment, telephoneswitching, traffic controlsystems, industrial workstations, servers, powersupplies, UPS, industrialcontrols and weldersFeatures/Benefits■ Rugged construction -Designed to perform inindustrial environments■ Design flexibility -Available with fast-on, bolt-interminals or wire leadsSingle stage and dual stage■ Performance -Ideally suited for productsthat must conform to FCCpart 15 regulationsHigh performance in bothmetal and plastic casesExcellent attenuation forhigh voltage impulse■ Agency approvals -Several styles are ULrecognized, CSA certified,TÜV approved (tested andfound to be in accordancewith VDE 0565 Part 3)■ Rugged construction -Designed to perform inindustrial environments■ Design flexibility -Available with fast-onor bolt-in terminalsSingle and dual stageDelta and Wyeconfigurations■ Performance -Ideally suited for productsthat must conform to FCCpart 15 regulationsBoth metal and plastic casesprovide high performanceExcellent attenuation forhigh voltage impulse■ Agency approvals -Agency approvals pending■ Rugged construction -Metal enclosures builtto withstand MIL-STDenvironmental conditions■ Design flexibility -Standard catalog parts availableParts designed to meetcustomers’ requirements■ Performance -<strong>EMI</strong> designs provideexcellent isolation and highfrequency performance■ Military approvals -Available to meet MIL-F-15733 and MIL-STD-461Military testing IAW MIL-STD-202, MIL-STD-105■ <strong>EMI</strong> design verification -Equipment verification canbe accomplished through<strong>Spectrum</strong> <strong>Control</strong>’s <strong>EMI</strong>test lab■ Rugged construction -Designed to perform inindustrial environments■ Design flexibility -<strong>Filters</strong> designed to meet customer’scircuit requirementsTransient protectionCircuit breakersVoltage cut-offOther options availableProvides quick and economicalsolutions to meet customers’specific requirementsIncreases speed-to-marketand decreases developmenttimeDesigns optimized throughEMC verification■ Agency approvals -Designed to meet NEBSand safety agency approvalsPerformanceCharacteristics■ Current ratings (max) -To 260 Amps■ Voltage ratings (max.) -From DC to 250 VAC,60 Hz■ Insertion loss range -Effective filtering from100 KHz to 30 MHz■ Temperature range --25°C to +85°C■ Leakage current range -0.35 mA to 3.0 mA max■ Current ratings (max) -3 Amp to 200 Amps■ Voltage ratings (max.) -250 VAC to 440 VAC■ Insertion loss range -Effective filtering from100 KHz to 30 MHz■ Temperature range --40°C to +85°C■ Leakage current range -Standard and low leakagedesigns available■ Current ratings (max.) -Up to 100 Amps■ Voltage ratings (max.) -400 VDC and 240 VACstandard; custom voltageratings available■ Insertion loss range -Effective filtering from10 KHz to 10 GHz■ Temperature range --55°C to +125°C■ Current ratings (max.) -Up to 250 Amps■ Voltage ratings (max.) -400 VDC and 240 VACstandard; custom voltageratings available■ Insertion loss range -Effective filtering from10 KHz to 10 GHz■ Temperature range --55°C to +125°C■ Leakage current range -Standard and low leakagedesigns availablePages 52-87 Pages 88-97 Pages 98-105 Pages 106-109www.spectrumcontrol.com/pline www.spectrumcontrol.com/3pline www.spectrumcontrol.com/multi www.spectrumcontrol.com/comcusSPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-585


<strong>Spectrum</strong> <strong>Control</strong>’s Expertise<strong>Spectrum</strong> <strong>Control</strong> is unique in providing an integratedapproach to EMC problem solving by offering customerconsulting, diagnostic testing, design and manufacturingservices. As a fully integrated manufacturer, we are ableto respond to short lead times and develop cost-effectivesolutions to satisfy your performance and budgetary needs.Test■■■■<strong>Spectrum</strong> <strong>Control</strong>’s Test Facility provides a total solutionfor your compliance issuesIn-house anechoic chamber and shielding roomNARTE certified engineering staffTests available for:• European emission and immunity regulations(CE Mark)• FCC Part 15• MIL standard testingDesign■■■■In-house <strong>EMI</strong> and power conditioning specialistsComprehensive computer modelingDesigns are “in-house” compliance verifiedCustom assemblies:• Incorporate <strong>EMI</strong> filtering, circuit breaker protection,transient suppression, voltage cut-off, power factorcorrection, harmonic suppression, remote sensingand other options to meet your specific requirements• Plug-and-play designs• Reduce your time to market• Lower your inventory needsManufacture■■■■■Flexible factoriesCustom designs<strong>Spectrum</strong> <strong>Control</strong>, Inc. ISO 9001 certifiedSchedule sharing programs availableVertically integrated supplier6SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Spectrum</strong> <strong>Control</strong>’s ExpertiseAs a complete source of EMC solutions, <strong>Spectrum</strong> <strong>Control</strong>combines state-of-the-art test facilities with proven expertisein the design and manufacture of <strong>EMI</strong>/RFI filteredpower products.<strong>Spectrum</strong> <strong>Control</strong> offers:Engineering Support – Our experienced engineering staffwill work closely with your design and manufacturing teamto provide rapid and cost-effective solutions meeting themost stringent <strong>EMI</strong> requirements.Reduced Lead Times and Volume Production – Ourvertical integration allows us to reduce lead times for bothprototype and production orders . . . ensuring on-timedelivery. This not only reduces your inventory, it savesyou time and money.Custom Solutions – We offer maximum design expertiseand versatility to meet the need of any unique filteringapplication. In addition, we’ll develop power conditioningsolutions with features such as back panels with <strong>EMI</strong>filtering and surge protection, circuit breakers, LEDsand voltage cut-off.Full Qualification Testing – We offer a fully integratedquality assurance process, as well as testing in compliancewith MIL-F-28861, MIL-F-15733, MIL-STD-202, and other<strong>EMI</strong> specifications. <strong>Spectrum</strong> <strong>Control</strong>’s facilities have beenaudited and qualified to MIL-I-45208 and are registeredto ISO 9001.Customer Support Programs – We will work closelywith your organization to help improve the final designand performance of your products, as well as increaseyour manufacturing and operational efficiency. <strong>Spectrum</strong><strong>Control</strong> has instituted a variety of programs designedto maximize these opportunities.■ Flexible manufacturing to cut cycle times andmeet deadlines■ EDI to streamline the transmitting of information■ Inventory Management through flexible shippingprograms■ Consignment/schedule sharing programsto accommodate customers’ forecasts■ Broader distribution base to make our productsmore readily available and accommodate vendorreduction plans■ New product development geared to meetingcustomer-specific requirements and targetsSPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-587


Application GuidelinesNeed for <strong>EMI</strong> suppressionGlobal regulatory agencies have established limits tothe amount of noise that man-made electronic devicescan radiate or conduct. These regulations have gainedgreater importance as the world’s electronic populationintensifies and the proximity of electronic devicesbecomes closer.<strong>EMI</strong> can propagate through two basicavenues: Conducted and RadiatedConducted refers to events where the <strong>EMI</strong> energy flowsthrough power lines, data cables and other wiring thatcarries functional data or power.Radiated refers to energy that is propagated bymagnetic or electric fields, which originate from otherelectronic or electrical systems.Interference typesThere are two modes of conducted noise: differentialmode (symmetrical or normal mode) and common mode(asymmetrical mode).Differential mode interference signals are present onone side of the line, referenced to the other. The currentsflow along one phase and return along another phase.Common mode interference signals are present on bothsides of the line referenced to ground. The current flowsfrom the source to ground along the ground path andreturns along the phases.Sources of <strong>EMI</strong>Electromagnetic interference can occur naturallyor through electronic sources. Lightning discharges,precipitation, sand and dust storms, and cosmic noiseare sources of natural <strong>EMI</strong>.<strong>EMI</strong> generated from power electrical products causethe most concern. These man-made sources, such aspower lines, rotating machinery, power supplies andelectronic transmission devices, all have their ownsignatures and noise pollution.<strong>EMI</strong> filters, insertion lossand attenuation<strong>Power</strong> line <strong>EMI</strong> filters are designed to attenuate(or reduce) all radio frequency emissions or energy thatis above the applicable EMC specification. Most powerline <strong>EMI</strong> filters utilize inductor/capacitor “low pass” componentconfigurations that pass all DC or low frequencyAC necessary energy and attenuate (suppress) higherfrequencies containing noise or unwanted energy.<strong>Power</strong> Filter InstallationPOWERINPUTLINEFILTERINCORRECTCABINETDENOTESCOUPLINGFROM NOISYCIRCUITSBACK TOLINEPOWERINPUTCLEANLINECORRECTLINE FILTERCABINETDENOTESCOUPLINGFROM NOISYCIRCUITSBACK TOLINETo insure a customer’s “in system” unit to unitattenuation uniformity of power line filters, an insertion lossproduction line test is performed by <strong>Spectrum</strong> <strong>Control</strong>, Inc.Each of the specific frequencies is measured usingRF test equipment and the “reference signal level” ofeach frequency is stored. Some systems sweep the entirefrequency range and store this “reference signal level”. Thefilter to be measured, tested, or evaluated is then “inserted”between the generator and receiver that established thestored “reference signal level” on the RF test analyzer.The measured difference without a filter (“the referencesignal level”) and with the filter “inserted” into the RF testequipment/analyzer is defined as insertion loss. The unitof measure for insertion loss is the decibel (dB). As notedon most curves in this bulletin, as frequency increases,the higher the insertion loss or dB value. The plot offrequency versus dB value establishes the typicalinsertion loss curve.Installation CriteriaProper installation of a filter network is critical to achievingsuccessful filtering of electromagnetic interference.<strong>Spectrum</strong> <strong>Control</strong> recommends that power line filters beinstalled where the power line enters the equipment. Thefilter acts as a barrier between polluted energy and cleanenergy going into your equipment. It is important that thefilter is connected to an effective ground plane and whereproximity does not couple radiated noise to the clean lines.8SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


Measurement Guidelines<strong>Spectrum</strong> <strong>Control</strong> has the capability to perform awide range of tests for <strong>EMI</strong> filters. Unique custom testingsystems, designed by <strong>Spectrum</strong> <strong>Control</strong> assure theaccuracy required in today’s demanding environments.Testing is performed by employing a 50 ohm source andload impedance per MIL-STD-220. The individual filterperformance is stated in terms of insertion loss. Overallattenuation reflects the filter’s interaction within the system.Individual filter performance may differ from system tosystem and each application should be verified throughsystem testing. Examples of various testing abilities andconfigurations are outlined below.Differential (Normal or Symmetrical)Mode Insertion LossDifferential mode noise is caused by non-sinusoidalconduction of rectifiers and other switching devicescreating harmonic distortion.This noise is predominant from the power frequencyto approximately 10 MHz. Since it follows conventionalcurrent flow, it is considered to be of the same magnitudebut opposite phase of the other line. <strong>Spectrum</strong> <strong>Control</strong>measures differential mode insertion loss in a 50 ohmsystem with Balun transformers as shown.Leakage CurrentLeakage is a measurement of reactive current (capacitance)to ground per line. <strong>Spectrum</strong> <strong>Control</strong> uses thefollowing test setup for leakage current measurement.ACSOURCE1 NEUTRAL TEST2 HIGH TEST12DEVICEUNDERTESTTIES TO CHASSISOF DEVICEAC Voltage DropAC voltage drop is defined as E in - E out = ACvoltage drop.<strong>Spectrum</strong> <strong>Control</strong> uses the following circuit for AC voltagedrop testing:E1v0.15 µFD1.5 KΩIN ACCORDANCE WITH U.L. 1283 METHODDUT(FILTER)INSULTATED TABLEE2A50ΩBALUNFILTERØ ABALUNSIGNALGENERATORFILTERØ BFILTERØ C50ΩRECEIVERDC Voltage DropDC voltage drop is performed on each line individually.This test provides the total DC voltage drop for that lineof the filter. The following circuit is used in testing:Common (Asymmetrical)Mode Insertion LossSince common mode insertion loss is of the samephase as the opposite line, they may not be of thesame magnitude, depending on the end system circuitry.<strong>Spectrum</strong> <strong>Control</strong> tests common mode insertion loss oneach line in a 50 ohm system as shown.EVDDUT(FILTER)ARS50ΩLINEFILTERLINE50ΩRECEIVERNEUTNEUTSPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-589


EMC Testing Solutions<strong>Spectrum</strong> <strong>Control</strong> is a solutions-oriented EMC testcorporation committed to effectively satisfying worldwideEMC standards for commercial and military equipment.Our EMC testing services offer you a flexible resourceto assist in product development by identifying andcorrecting <strong>EMI</strong> susceptibility and/or emission problems.Our commitment to our customers goes much furtherthan any other <strong>EMI</strong> filtered power products manufacturer.<strong>Spectrum</strong> <strong>Control</strong> has a fully equipped EMC TestLaboratory and experienced engineering staff readyto solve your most demanding EMC challenges.We can test your equipment, system or subsystem tovarious domestic and international regulatory standards,determine state of compliance, and develop the mostcompact and cost-effective solution. These services (EMCtesting and compliance recommendations) are availablefor a modest daily fee. It is not uncommon for clients leave<strong>Spectrum</strong> <strong>Control</strong>’s EMC Test Laboratory with a prototypein hand.State-of-the-art Testing■■■■■Two test environments available: anechoicchamber and shielded roomBaseline of device under test in ambient-freeanechoic chamberComputer controlled pre-selected <strong>EMI</strong> receiverswith quasi-peak detection accumulate data fordisplaying information in graphical or tabular formatsFiber optic coupled video cameras for dynamictest observationComputer generated test data reduces time andimproves accuracyTesting CapabilitiesUL Underwriter’s Laboratories, UL 1283MILITARYMIL-STD-461 A/B/C/D and MIL-STD-1399AUTOMOTIVESAE-J1113, SAE-J551COMMERCIALFCC-Part 15RTCA-DO-160 A/B/CBoeing-16050-2Bellcore-TR-NWT-001089INTERNATIONALEN 55011 (CISPR 11)EN 55014 (CISPR 14)EN 55022 (CISPR 22)IEC-1000-4-02 ESDIEC-1000-4-03 RFIIEC-1000-4-04 EFTIEC-1000-4-05 Surge10SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


EMC Testing SolutionsOne of the most significant advantages of <strong>Spectrum</strong><strong>Control</strong>’s testing services lies in our experience andexpertise in evaluating, designing and producing productsfor the suppression of <strong>EMI</strong>. Our approach to EMC testingenables us to identify, as well as solve any problems orpotential problems found in your system. <strong>Spectrum</strong>’sdesign and production engineers will work with yourengineering team to develop a filter solution thateliminates your <strong>EMI</strong> problems.Once we have identified an <strong>EMI</strong> failure, we will developa prototype design, integrate the EMC modification intoyour device or system, and verify compliance to theappropriate test specifications. <strong>Spectrum</strong> <strong>Control</strong> maintainssemi-automated and automated manufacturing facilitiesto economically produce the modification installed duringtesting. Through these capabilities your equipment willleave <strong>Spectrum</strong> <strong>Control</strong> with a prototype, as well asa fully compliant system.Test■ <strong>Spectrum</strong> <strong>Control</strong> Test Facilitywill define compliance issues■ In-house anechoic chamberand shielded room■ NARTE certified engineering staff■ Test available for:• European emissionand immunity regulations• FCC Part 15• MIL 461 SeriesDesign■ In-house <strong>EMI</strong> specialists■ Computer modeling■ CAD systems internet accessible■ Designs are “in-house”compliance verified■ Value-added designs:• Incorporate circuits andadditional components• Ease of production assembly• Lower inventory needsManufacture■ Flexible operations■ Custom designs built in U.S.A.■ ISO 9001 certified facilities■ Workmanship MIL-STD-2000certified■ Schedule sharing programsavailable■ Vertically integrated<strong>EMI</strong> filter supplierSPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5811


High CurrentDC Single LineFeed-thru SeriesSingle Line <strong>Filters</strong>Features■■■Voltage Rating 130VDCC Configuration with Class Y4 capacitorsCurrent rating up to 300 Amps■ Operating Temperature Range: -40C to +85C■■■■■Excellent filtering in compact packageBolt-in style with D-shaped bushing for easy installationLow cost <strong>EMI</strong> solutionDesign flexibilityUL and Semko approvedApplications■■■■■■Telecommunications (cellular base stations,telephone switching racks, etc.)<strong>Power</strong> suppliesMedical EquipmentC.O.T.S. (Commercial-Off-The-Shelf) MilitaryIndustrial equipment controlsData Transmission EquipmentSpecificationsPart Rated Min. Minimum Insertion Loss (db)*Number Current Cap. .01MHz .10MHz 1MHz 10MHz 100MHz 1000MHz52-226-011-10 10A52-226-011-16 16A52-226-011-32 32A10nF – 4 21 41 6052-226-011-63 63A52-226-011-100 100A 47nF 2 15 34 53 7452-226-011-200 200A –52-226-011-250 250A 100nF 5 21 40 60 8552-226-011-300 300A52-226-021-16 16A52-226-021-32 32A 47nF 2 15 34 53 7452-226-031-63 63A52-226-021-100 100A 100nF 5 21 40 60 8552-226-021-200 200A52-226-021-250 250A 470nF 2 16 33 52 75 9052-226-021-300 300A52-226-031-16 16A52-226-031-32 32A 100nF – 5 21 40 60 8552-226-031-63 63A52-226-031-100 100A 470nF 2 16 33 52 7552-226-031-200 200A52-226-031-250 250A 1000nF 6 20 40 60 8552-226-031-300 300A52-226-041-16 16A 9052-226-041-32 32A 470nF 2 16 33 52 7552-226-041-63 63A52-226-041-100 100A 1000nF 6 20 40 60 8552-226-041-200 200A 4700nF 15 35 54 74 90* Optimum performance with proper installation12SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


High CurrentDC Single LineFeed-thru SeriesFBWORKORDER NO.ECDDATE CODE.025 (.64) SHOULDERASINGLE "D"MOUNTING FLATSingle Line <strong>Filters</strong>DimensionsPart Number A B C D E F52-226-011-10 2.24 (57) 0.39 (10) 0.51 (13) 0.56 (14.29) 0.63 (16)52-226-011-160.71 (18)2.48 (63) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18)52-226-011-3252-226-011-63 3.78 (96) 0.55 (14) 0.87 (22) 1 (25.40) 1.02 (26) 1.18 (30)52-226-011-100 4.45 (113) 0.63 (16)1.26 (32)1.06 (27) 1.25 (31.75)52-226-011-200 5.12 (130) 1.57 (40)1.30 (33)52-226-011-2500.75 (19)5.83 (148)52-226-011-3001.57 (40) 2 (50.80) 1.81 (46) 1.65 (42)52-226-021-162.95 (75) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18)52-226-021-321.18 (30)52-226-031-63 3.78 (96) 0.55 (14) 0.87 (22) 1 (25.40) 1.02 (26)52-226-021-100 4.45 (113) 0.63 (16)1.26 (32)1.06 (27) 1.25 (31.75)52-226-021-200 5.12 (130) 1.57 (40)1.30 (33)52-226-021-2500.75 (19)6.30 (160)52-226-021-3001.57 (40) 2 (50.80) 1.81 (46) 2.13 (54)52-226-031-162.95 (75) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18)52-226-031-321.18 (30)52-226-031-63 3.78 (96) 0.55 (14) 0.87 (22) 1 (25.40) 1.02 (26)52-226-031-100 4.45 (113) 0.63 (16)1.25 (31.75) 1.26 (32) 1.30 (33)1.06 (27)52-226-031-200 5.79 (147) 1.5 (38.10) 1.57 (40) 1.97 (50)52-226-031-2500.75 (19)7.01 (178)52-226-031-3001.57 (40) 2 (50.80) 1.81 (46) 2.83 (72)52-226-041-163.23 (82)0.71 (18)52-226-041-320.63 (16) 1.25 (31.75)1.06 (27)52-226-041-63 3.98 (101)1.02 (26)1.30 (33)52-226-041-100 5.24 (133)1.5 (38.10) 1.26 (32) 1.97 (50)0.75 (19)52-226-041-200 6.50 (165) 1.57 (40) 2 (50.80) 1.57 (40) 2.68 (68)Dimensions in inches (mm)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5813


Single Line <strong>Filters</strong>High CurrentDC Single LinePi SeriesFeatures■■■■■■■Voltage Rating 130VDCPi Configuration with Class Y4 capacitorsCurrent rating up to 200 AmpsExcellent filtering in compact packageBolt-in style with D-shaped bushing for easy installationLow cost <strong>EMI</strong> solutionUL and Semko approvedApplications■■■■■■Telecommunications (cellular base stations,telephone switching racks, etc.)<strong>Power</strong> suppliesMedical EquipmentC.O.T.S. (Commercial-Off-The-Shelf) MilitaryIndustrial equipment controlsData Transmission EquipmentCircuit DiagramSpecificationsPart Rated Min. Minimum Insertion Loss (db) *Number Current Cap. (2X) .01MHz .10MHz 1MHz 10MHz 100MHz 1000MHzStandard Performance52-226-020-10 10A230.5 87052-226-020-16 16A 10nF35–52-226-020-32 32A 2 10 23 509052-226-020-63 63A 100nF 8 27 6752-226-020-100 100A4 2170 90470nF3052-226-020-200 200A 7 23 60High Performance52-226-029-10 10A52-226-029-16 16A 100nF – 8 25 7552-226-029-32 32A52-226-029-63 63A 470nF 4 21 35 7090 9052-226-029-100 100A 1000nF 8 26 57 7352-226-029-200 200A 4700nF 20 40 85 90* Optimum performance with proper installation14SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


High CurrentDC Single LinePi SeriesDFABECSingle Line <strong>Filters</strong>DATE CODEWORKORDER NO..025 (.64) SHOULDERSINGLE "D"MOUNTING FLATDimensionsPart Number A B C D E FStandard Performance52-226-020-10 3.54 (90) 0.63 (16) 1.93 (49)52-226-020-160.47 (12) 0.67 (17) 0.75 (19.05)3.86 (98)52-226-020-320.71 (18) 2.09 (53)52-226-020-63 6.30 (160) 0.55 (14) 0.87 (22) 1 (25.40) 1.02 (26) 3.70 (94)52-226-020-100 7.24 (184) 0.63 (16)1.25 (31.75) 1.26 (32) 4.09 (104)1.06 (27)52-226-020-200 8.23 (209) 0.75 (19) 1.50 (38.10) 1.57 (40) 4.41 (112)High Performance52-226-029-10 5.12 (130) 0.63 (16) 3.50 (89)52-226-029-160.47 (12) 0.67 (17) 0.75 (19.05)5.47 (139)52-226-029-320.71 (18) 3.70 (94)52-226-029-63 6.81 (173) 0.63 (16)1.25 (31.75) 1.02 (26) 4.13 (105)1.06 (27)52-226-029-100 8.98 (228)1.50 (38.10) 1.26 (32) 5.71 (145)0.75 (19)52-226-029-200 11 (279) 1.57 (40) 2 (50.80) 1.57 (40) 7.17 (182)Dimensions in inches (mm)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5815


High CurrentAC Single LineFeed-thru SeriesSingle Line <strong>Filters</strong>16Features■■■■■■■■Voltage Rating 250VACC Configuration with Class Y2 capacitorsCurrent rating up to 300 AmpsExcellent filtering in compact packageBolt-in style with D-shaped bushing for easy installationLow cost <strong>EMI</strong> solutionDesign flexibilityUL and Semko approvals pendingApplications■■■■■■Telecommunications (cellular base stations,telephone switching racks, etc.)<strong>Power</strong> suppliesMedical EquipmentC.O.T.S. (Commercial-Off-The-Shelf) MilitaryIndustrial equipment controlsData Transmission EquipmentSpecificationsPart Rated Min. Minimum Insertion Loss (db) *Number Current Cap. .01MHz .10MHz 1MHz 10MHz 100MHz 1000MHz52-226-016-10 10A 2.2nF - 9 30 4552-226-016-16 16A52-226-016-32 32A4.7nF – 2 15 34 5452-226-016-63 63A 10nF 4 21 41 6052-226-016-100 100A 47nF 2 15 34 53 7452-226-016-200 200A52-226-016-250 250A 100nF 5 21 40 60 8552-226-016-300 300A52-226-026-10 10A 4.7nF 2 15 34 5452-226-026-16 16A–10nF52-226-026-32 32A –4 21 41 6052-226-026-63 63A 47nF 2 15 34 53 7452-226-026-100 100A 100nF 5 21 40 60 8552-226-026-200 200A52-226-026-250 250A 220nF 10 27 47 67 9052-226-026-300 300A52-226-036-16 16A 47nF 2 15 34745352-226-036-32 32A 33nF 3 16 35 9052-226-036-63 63A 100nF 5 21 40 60 8552-226-036-100 100A 220nF 10 27 47 6752-226-036-200 200A52-226-036-250 250A 470nF 2 16 33 52 759052-226-036-300 300A52-226-046-16 16A 100nF 5 21 40 60 8552-226-046-32 32A 47nF – 2 15 34 53 7452-226-046-63 63A 220nF 10 27 47 6752-226-046-100 100A 470nF 2 16 33 52 7552-226-046-200 200A9052-226-046-250 250A 1000nF 6 20 40 60 8552-226-046-300 300A* Optimum performance with proper installationSPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


High CurrentAC Single LineFeed-thru SeriesWORKORDER NO.FBECDDATE CODE.025 (.64) SHOULDERSINGLE "D"MOUNTING FLATSingle Line <strong>Filters</strong>ADimensionsPart Number A B C D E F52-226-016-10 2.24 (57) 0.39 (10) 0.51 (13) 0.56 (14.29) 0.63 (16)52-226-016-160.71 (18)2.48 (63) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18)52-226-016-3252-226-016-63 3.78 (96) 0.55 (14) 0.87 (22) 1 (25.40) 1.02 (26) 1.18 (30)52-226-016-100 4.45 (113) 0.63 (16)1.25 (31.75) 1.26 (32)1.06 (27)52-226-016-200 5.12 (130) 1.5 (38.10) 1.57 (40)1.30 (33)52-226-016-2500.75 (19)5.83 (148)52-226-016-3001.57 (40) 2 (50.80) 1.81 (46) 1.65 (42)52-226-026-10 2.24 (57) 0.39 (10) 0.51 (13) 0.56 (14.29) 0.63 (16)52-226-026-160.71 (18)2.48 (63) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18)52-226-026-3252-226-026-63 3.78 (96) 0.55 (14) 0.87 (22) 1 (25.40) 1.02 (26) 1.18 (30)52-226-026-100 4.45 (113) 0.63 (16)1.25 (31.75) 1.26 (32)1.06 (27)52-226-026-200 5.12 (130) 1.5 (38.10) 1.57 (40)1.30 (33)52-226-026-2500.75 (19)5.83 (148)52-226-026-3001.57 (40) 2 (50.80) 1.81 (46) 1.65 (42)52-226-036-162.95 (75) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18)52-226-036-321.18 (30)52-226-036-63 3.78 (96) 0.55 (14) 0.87 (22) 1 (25.40) 1.02 (26)52-226-036-100 4.57 (116) 1.06 (27) 1.26 (32) 1.30 (33)1.5 (38.10)52-226-036-200 5.79 (147)1.57 (40) 1.97 (50)0.75 (19)52-226-036-2501.57 (40)6.30 (160)2 (50.80) 1.81 (46) 2.13 (54)52-226-036-30052-226-046-16 3.03 (77) 0.55 (14) 0.87 (22)52-226-046-32 2.95 (75) 0.47 (12) 0.67 (17)1 (25.40) 0.71 (18) 1.18 (30)52-226-046-63 4.45 (113) 0.63 (16)1.25 (31.75) 1.02 (26) 1.30 (33)1.06 (27)52-226-046-100 5.24 (133) 1.5 (38.10) 1.26 (32)1.97 (50)52-226-046-200 5.79 (147)1.57 (40)0.75 (19)52-226-046-2501.57 (40) 2 (50.80)6.30 (160)1.81 (46)2.13 (54)52-226-046-300Dimensions in inches (mm)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5817


Single Line <strong>Filters</strong>High CurrentAC Single LinePi SeriesFeatures■■■■■■■■Voltage Rating 250VACPi Configuration with Class Y2 capacitorsCurrent rating up to 300 AmpsExcellent filtering in compact packageBolt-in style with D-shaped bushing for easy installationLow cost <strong>EMI</strong> solutionDesign flexibilityUL and Semko approvals pendingApplications■■■■■■Telecommunications (cellular base stations,telephone switching racks, etc.)<strong>Power</strong> suppliesMedical EquipmentC.O.T.S. (Commercial-Off-The-Shelf) MilitaryIndustrial equipment controlsData Transmission EquipmentCircuit DiagramSpecificationsPart Rated Min. Minimum Insertion Loss (db) *Number Current Cap. (2X) .01MHz .10MHz 1MHz 10MHz 100MHz 1000MHzStandard Performance52-226-037-10 10A 4.7nF – 4 19 7752-226-037-16 16A52-226-037-32 32A10nF – 1 8 22 5052-226-037-63 63A 47nF 4 21 52 80 9052-226-037-100 100A 8 25 7352-226-037-200 200A100nF 152-226-037-250 250A 9 26 759052-226-037-300 300AHigh Performance52-226-019-10 10A 10nF 1 9 3052-226-019-16 16A–8022nF3 15 4752-226-019-32 32A52-226-019-63 63A 150nF 1 12 27 75 9052-226-019-100 100A 3952-226-019-200 200A470nF 4 2152-226-019-250 250A 5785 9052-226-019-300 300A* Optimum performance with proper installation18SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


High CurrentAC Single LinePi SeriesDFABECSingle Line <strong>Filters</strong>DATE CODEWORKORDER NO..025 (.64) SHOULDERSINGLE "D"MOUNTING FLATDimensionsPart Number A B C D E FStandard Performance52-226-037-10 3.86 (98) 0.63 (16) 2.24 (57)52-226-037-160.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18) 2.40 (61)4.17 (106)52-226-037-3252-226-037-63 6.30 (160) 0.55 (14) 0.87 (22) 1 (25.40) 1.02 (26) 3.7 (94)52-226-037-100 7.24 (184) 0.63 (16)1.25 (31.75) 1.26 (32) 4.09 (104)1.06 (27)52-226-037-200 8.23 (209) 1.57 (40) 4.41 (112)52-226-037-2500.75 (19)1.5 (38.10)7.87 (200)1.57 (40)52-226-037-3001.81 (46) 3.66 (93)High Performance52-226-019-10 4.21 (107) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.63 (16) 2.6 (66)52-226-019-1652-226-019-324.57 (116) 0.55 (14) 0.87 (22) 1 (25.40) 0.71 (18) 2.72 (69)52-226-019-63 6.81 (173) 0.63 (16)1.25 (31.75) 1.02 (26) 4.13 (105)1.06 (27)52-226-019-100 8.98 (228) 1.5 (38.10) 1.26 (32) 5.71 (145)52-226-019-200 9.57 (243)5.75 (146)0.75 (19)52-226-019-2501.57 (40) 2 (50.80) 1.57 (40)10.5 (267)6.30 (160)52-226-019-300Dimensions in inches (mm)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5819


Single Line <strong>Filters</strong>High CurrentSingle LineFeed-thru <strong>Filters</strong>High current single line feed-thru filters from <strong>Spectrum</strong><strong>Control</strong> are ideal to meet broad frequency applications.This series filters <strong>EMI</strong>/RFI with 150-500 Amp current withAC and DC voltages. These filters are ideal for cellularbase stations, telephone switching stations and highvoltage power supply applications.Features■■■■■■■■■■■■Ideal for high current applicationsExcellent filtering in a compact, durable packageBolt-in style for easy installationCurrent ratings to 500 AmpsVoltage ratings up to 1000VDC and 240VACAvailable with single, dual, and triple feed-thrusVarious capacitance ratings (up to 1.68 µF)Rugged construction for indoor and outdoorapplicationsVarious mounting brackets availableLow cost <strong>EMI</strong> solutionDesign flexibilityCustom mechanical configurations availableApplications■■■Telecommunications (cellular base stations,telephone switching racks, etc.)<strong>Power</strong> suppliesServersElectrical SpecificationsCurrent Ratings/Bolt Size:Typical Insertion Loss (dB)9080706050403020101.68µF0.03µF0.04µF150 Amps . . . . . . 10 mm200 Amps . . . . . . 12 mm250 Amps . . . . . . 12 mm300 Amps . . . . . . 14 mm400 Amps . . . . . . 16 mm500 Amps . . . . . . 18 mmTemperature Range: -25°C to 85°C0.02µF0.01µF00.01 0.1 1 10 1001000Frequency (MHz)PartFigureVoltage Rating @ Current CapacitanceNumber-40C to +85C Rating Value52-226-001 A 50VDC Max. 300 Amps 0.02 µF min. @ 50VDC52-226-002 B 50VDC Max. 300 Amps 0.02 µF min. @ 50VDC52-226-006 C 50VDC Max. 150 Amps 0.02 µF min. @ 50VDC52-226-008 D 75VDC Max. 200 Amps 0.02 µF min. @ 50VDC52-226-009 E 50VDC Max. 150 Amps 0.02 µF min. @ 50VDC52-267-008 F 200VDC Max. 200 Amps 0.02 µF min. @ 40VDC52-226-004 F 200VDC Max./240 VAC 200 Amps 1.68 µF min. @ 50VDC52-226-015 G 200VDC Max./240 VAC 200 Amps 1.68 uF min. @ 50VDC52-267-002 H 200VDC Max./240 VAC 200 Amps 1.68 µF min. @ 40VDC52-267-003 J 200VDC Max./240 VAC 200 Amps 1.68 µF min. @ 40VDC52-267-009 F 200VDC Max./240 VAC 60 Amps 1.68 µF min. @ 50VDC52-267-010 K 200VDC Max./240 VAC 250 Amps 1.68 µF min. @ 40VDC52-267-011 K 200VDC Max./240 VAC 100 Amps 1.68 µF min. @ 40VDC52-267-012 K 250VDC Max. 100 Amps 1.00 µF+20% @ 40VDC20SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


High CurrentSingle LineFeed-thru <strong>Filters</strong>Mechanical DimensionsFigure A4.67 (118.6)Figure B.314 (8.0) (2x)4.20 (106.6) .236 (6.0) (2x)1.221 (31.0).314 (8.0) (2x)4.669 (118.6)4.196 (106.6).236 (6.0) (2x)1.811 (46.0)2.441 (62.0)1.811(46.0)1.220(31.0)2.441(62.0)1.295 ± .02 (2x)(32.9 ± 0.6)4.015 ± .02(102.0 ± 0.6)2.598(66.0)MAX.1.498(38.0)1.587(40.3)SCI 24-0058-4800M14 x 2.0 - 6g STUD (2x)SCI 22-0833-0100BRACKET ASSEMBLY2.047 ± .02(52.0 ± 0.6)SCI 24-0058-4800.125 (3.18) TYP.FOR LABEL LOCATIONDATE CODEØ .204 ± .005 THRU (4x)(5.2 ± .13).063(1.6)1.295 ± .02(32.9 ± 0.6)4.015 ± .02(102.0 ± 0.6)(2x)2.598 MAX.(66.0)1.496(38.0)1.586(40.3) Ø .204 (5.2)THRU (4x)SCI 24-0058-4800M14 x 2.0-6g STUD (2x).276 ± .016(7 ± .4).125 (3.18) TYP.FOR LABELLOCATIONDATE CODE.063(1.6)Single Line <strong>Filters</strong>.826 (21.0)MIN. THRD.LENGTHSCI 24-0058-4700 (3x)Ø1.50(38.8).826 (21.0)MIN. THRD. LENGTH45˚ CHAMFERBOTH ENDSØ 1.25 (31.75)Figure CØ .874 (22.20) (2x)Figure DØ .874 (22.20) (2x).177 (4.5) (2x)1.299(33.0)5.393 (137.0)5.039 (128.0).177 (4.5) (2x).826 (21.0)1.652 (42.0).177 (4.5) (2x)1.299(33.0)5.393 (137.0)5.039 (128.0) .177 (4.5) (2x).826 (21.0)1.652 (42.0)1.295 ± .02 (2x)(32.9 ± 0.6)1.984(49.5)1.496(38.0).807 (20.5)Ø .204 ± .005(5.2 ± .13) THRUØ .118 ± .005(3.0 ± .13)M10 x 1.5-6g STUDTIN PLATED BRASS.248 (6.3) (2x)2.01.984(49.5)M10 x 1.5-6g STUD-BRASS (UNPLATED)1.295 ± .02 (2x)(32.9 ± 0.6)1.496(38.0).807 (20.5).248 [6.3] (2x)Ø .204 ± .005(5.2 ± .13) THRU (4x)Ø .118 ± .005(3.0 ± .13)M10 x 1.5-6g STUDTIN PLATED BRASS4.015 ± .02(102.0 ± 0.6)2.598 MAX.(66.0).429 (10.9) .063 (1.6)1.413 ± .002(35.9 ± 0.6)2.717 ± .02(89.0 ± .6)1.89 0± .02 MAX.(48.0 ± 0.6)7.0MIN..429 [10.9] .063 (1.6)1.421 ± .012[36.1 ± 0.3]M10 x 1.5-6g STUD-BRASS (UNPLATED).826 (21.0) MIN. DATE CODEØ 1.25(31.75).826 (21.0) MIN.DATE CODEM10 x 1.5-6g STUDTIN PLATED BRASSØ 1.25(31.75)Figure E.177 (4.5) (2x)1.299(33.0)1.295 ± .02 (2x)(32.9 ± 0.6)1.984(49.5)Ø .874 (22.20) (2x)5.393 (137.0)5.039 (128.0) .177 (4.5) (2x).826 (21.0)1.652 (42.0)1.496(38.0).807 (20.5)Ø .204 ± .005(5.2 ± .13) THRU (4x)Ø .118 ± .005(3.0 ± .13)M10 x 1.5-6g STUDTIN PLATED BRASS.063 (1.6)Figure F(6x) ø 0.185 ±0.004(4.70 ±0.1)(2x) ø1.378 ± 0.004(MAX) (35.0 ±0.1)1.102 ±0.02(28.0 ± .5)3.406(86.5)0.197(5.00)3.799(96.5)1.909 ±0.02(48.5 ±0.5)1.801(45.75)0.197(5.00)0.689(17.5)1.053 ±0.01(26.75 ±0.3)1.378(35.0)0.197(5.00)1.772(45.0)M10x1.5 – 6g STUDS2.598(66.0) MAX.4.015 ± .02(102.0 ± .6).826 (21.0) MIN..961 ±0.02(24.4 ±0.5)3.976 ±0.02(101.0 ±0.5).921 (23.4).047(1.2)SQ 52 - 226 - 004200VDC 200A XXXX1.890(48.0)1.969 ±0.02(50.0 ±0.5)Ø 1.25(31.75)Dimensions in inches (mm)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5821


High CurrentSingle LineFeed-thru <strong>Filters</strong>Figure GFigure HSingle Line <strong>Filters</strong>Ø 1.378(35.0).964(25.4)1.259(32.0).248(6.3) 1.889(48.0)7.480 + .787/-0(190.0 + 20.0/-0).078(2.0)MAX.RED.984(25.0)3.956(100.5)3.405(86.5)1.702(43.25) 1.506(38.25)1.023(26.0)1.909 ± 1.968(48.5 ± 50)1.378(35.0)1.929(49.0)PEM CLS-M4-1(6 PLACES)BLACK8.858 + .787/-0(225.0 + 20.0/-0)10.433 + .78/-0(265.0 + 20.0/-0)2.955 (75.0)5.516 (140.0)2.726 (69.2)1.363 (34.6)M10 x 1.5-6g STUD2.092 (53.10)1.382 (35.08)5.520 (140.10)1.777 (45.10)3.428 (87.00)2.719 (69.00)1.52 (.060)Figure JFigure K4.807 (122.00)2.403 (51.00)Ø .283 (7.2) (2x)3.799 (96.5)3.406 (86.50)1.801(15.75)0.197 (5.0)0.197 (5.0)2.955 (75.0)PEM BSOS-M4-6 (6x)0.689 (17.5)1.772 (45.0)ø 0.185±0.004(6x) (4.70±0.1)1.378 (35.00)2.726 (69.20)4.570 (116.00)5.516 (140.0)2.285 (58.00)(MAX) ø 1.378±0.004(2x) (35.0±0.1)1.909±0.02(48.5±0.5).197(5.0)1.053±0.01(26.75±0.3)1.363 (34.60)2.092 (53.10)0.610±0.02(15.5±0.5)5.520 (140.10)1.382 (35.08).080 (1.52).047 (1.2).039 (1.00)1.777 (45.10)3.428 (87.00)2.719 (69.00)0.118±0.02(3±0.5)3.19±0.16(81.0±4)1.890 (48.0)1.969±0.02(50.0±0.5)M10 x 1.5-6g STUDDimensions in inches (mm)22SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


High CurrentFiltered Terminal BlocksFeatures■■■■Ideal for high current applicationsDesign flexibilityAvailable in 2 x 2 thru 2 x 6 positionsUL approvedApplicationsSpecifications■ Telecommunications switching networksELECTRICALVoltage rating: 100 VDC per terminal■ Cellular base stationsCapacitance: .015µF* +80% / -20% per cap■ <strong>Power</strong> supplies.030µF +80% / -20% per pair■ UPSDielectric■ Instrumentationwithstanding voltage: 1000VDC for 1 minuteCurrent rating: 60 Amps max per terminal■ High reliability radar and transmission systems■ Industrial controls■ <strong>Power</strong> distribution Typical Insertion Loss — dB:In 50 Ohm Circuit1.625(41.3)1.10 (27.9)1.15 (29.1)4.600 (116.8)R.125 (3.2) (4X).65 MIN (16.5) (6X)8-32 THREADEDINSERTS (4X).80 MIN (20.3)1 MHz....... 8 70 MHz......... 365 MHz....... 24 100 MHz......... 3310 MHz....... 32 160 MHz......... 2550 MHz....... 38 200 MHz......... 25MECHANICALCenter spacing: US .200: (5.08 mm)Wire size: AWG #12-26Screw material: steel, zinc chromate plateRecommended PCBhole diameter: .05" (1.30 mm) contact holeMolded material: UL rated 94VO polyamideTightening torque: 2.5 in.-lbs. max. (28 Ncm)Terminal:Brass, tin-platedFiltered Terminal Blocks.75 (19.0) (5X).172 (4.3) (4X)* For filter elements with additional capacitance values,consult factory.2.625(66.7)2.025(51.4).75 (19.0)5.0 (127)5.6 (142.2)PANEL CUTOUT4.6 (116.8)5.0 (127)1.685 2.025(42.8) (51.4)Part Number of A B CNumber Terminals in. (mm) in. (mm) in. (mm)52-1013-102 2x2 2.60 66.04 2.00 50.80 1.66 42.1652-1013-103 2x3 3.35 85.09 2.75 69.85 2.41 61.2152-1013-104 2x4 4.10 104.14 3.50 88.90 3.16 80.2552-1013-105 2x5 4.85 123.19 4.25 107.95 3.91 99.3152-1013-106 2x6 5.60 142.24 5.00 127.00 4.66 118.36Dimensions in inches (mm)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-835-1650 • Fax: 814-835-1651 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5823


<strong>Power</strong> Entry ModulesBolt-in Rear Terminals<strong>Power</strong> Entry Modules60-BPR & BPS SeriesFeaturesTested and found to beIAW VDE 0565 Part 3.■ Ideally suited for products that mustconform to FCC part 15 regulations■ Metal case offers high performance■ Meets over voltage of IEC 664 category IIand complies with IEC 950■ Uses IEC connector that meets most safety standards■ Solder lug and Fast-on tab terminals available■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 25)■ UL approved low leakage version also availableCircuit Diagram1L 13C YC YApplications■ Digital equipmentEC XE■ Personal computers and peripherals■ Measuring instruments■ Monitor and display units24SpecificationsModel*Rated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y C X (L 1 ) Rise (Max.)60-XXX-010-3-20.35mA 2200pF ± 20%.022uF ± 20%60-XXX-010-3-4250VAC1A.047uF ± 20%6.0mH 30°C60-XXX-010-5-20.50mA 3300pF ± 20%.022uF ± 20%60-XXX-010-5-4 .047uF ± 20%60-XXX-020-3-20.35mA 2200pF ± 20%.022uF ± 20%60-XXX-020-3-4250VAC2A.047uF ± 20%2.4mH 30°C60-XXX-020-5-20.50mA 3300pF ± 20%.022uF ± 20%60-XXX-020-5-4 .047uF ± 20%60-XXX-030-3-20.35mA 2200pF ± 20%.022uF ± 20%60-XXX-030-3-4250VAC3A.047uF ± 20%1.2mH 30°C60-XXX-030-5-20.50mA 3300pF ± 20%.022uF ± 20%60-XXX-030-5-4 .047uF ± 20%60-XXX-060-3-20.35mA 2200pF ± 20%.022uF ± 20%60-XXX-060-3-4250VAC6A.047uF ± 20%0.53mH 45°C60-XXX-060-5-20.50mA 3300pF ± 20%.022uF ± 20%60-XXX-060-5-4 .047uF ± 20%60-XXX-100-3-20.35mA 2200pF ± 20%250VAC10A60-XXX-100-5-2 0.50mA 3300pF ± 20%.022uF ± 20% 0.26mH 45°C60-BPR-150-3-11 250VAC 15A 0.35mA 2200pF ± 20% .01uF ± 20% 0.15mH 45°CNote: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 45gInput: Compatible with IEC-320* Substitute BPR or BPS for XXXBPS - Solder lug terminalsBPR - Fast-on tab terminals24 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Entry ModulesBolt-in Rear Terminals60-BPR & BPS SeriesTemperature CharacteristicsCurrent (%)120100806040201.967(50)1.573(40).944 (24).846(21.5).252(6.4)(2x) .142(3.6)1.181(30)2.263 (57.5)1.476 (37.5)0.807(20.5).157(4)1.10(28)<strong>Power</strong> Entry Modules020 30 40 50 60 70 80 90Ambient Temperature (°C)* General tolerance± .012 (0.3)Dimensions in inches (mm)Common ModeNormal ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeterInsertion Loss (dB)8060-BPX-010;-020;-0307060-BPX-010-5-X60504060-BPX-020-5-X3060-BPX-030-5-X2010Insertion Loss (dB)8060-BPX-010;-020;-0307060-BPX-010-5-X60504060-BPX-020-5-X3060-BPX-030-5-X201000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)8060-BPX-060;-1008060-BPX-060;-100Insertion Loss (dB)70605040302060-BPX-060-5-X60-BPX-100-5-XInsertion Loss (dB)70605040302060-BPX-060-X-460-BPX-060-X-260-BPX-100-X-2101000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5825


<strong>Power</strong> Entry ModulesBolt-in Right Angle Terminals<strong>Power</strong> Entry Modules60-BPF SeriesFeaturesTested and found to beIAW VDE 0565 Part 3.■ Ideally suited for products that mustconform to FCC part 15 regulations■ Metal case offers high performance■ Meets over voltage of IEC 664 category IIand complies with IEC 950■ Uses IEC connector that meets most safety standards■ PCB mounting types available (see page 54)■ Length under tab is shortened for small spaces■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 27)■ UL approved low leakage version also availableCircuit Diagram1L 13C YC YApplications■ Digital equipmentEC XE■ Personal computers and peripherals■ Measuring instruments■ Monitor and display units24SpecificationsModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y C X (L 1 ) Rise (Max.)60-BPF-010-3-20.35mA 2200pF ± 20%.022uF ± 20%60-BPF-010-3-4250VAC1A.047uF ± 20%60-BPF-010-5-20.50mA 3300pF ± 20%.022uF ± 20%60-BPF-010-5-4 .047uF ± 20%60-BPF-020-3-20.35mA 2200pF ± 20%.022uF ± 20%60-BPF-020-3-4250VAC2A.047uF ± 20%60-BPF-020-5-20.50mA 3300pF ± 20%.022uF ± 20%60-BPF-020-5-4 .047uF ± 20%60-BPF-030-3-20.35mA 2200pF ± 20%.022uF ± 20%60-BPF-030-3-4250VAC3A.047uF ± 20%60-BPF-030-5-20.50mA 3300pF ± 20%.022uF ± 20%60-BPF-030-5-4 .047uF ± 20%60-BPF-060-3-20.35mA 2200pF ± 20%.022uF ± 20%60-BPF-060-3-4250VAC6A.047uF ± 20%60-BPF-060-5-20.50mA 3300pF ± 20%.022uF ± 20%60-BPF-060-5-4 .047uF ± 20%Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 50gInput: Compatible with IEC-3206.0mH 30°C2.4mH 30°C1.2mH 30°C0.53mH 45°C26 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Entry ModulesBolt-in Right Angle Terminals60-BPF SeriesTemperature CharacteristicsCurrent (%)1201008060402060-BPFFast-onTerminals.865(22)1.967 (50)1.573 (40)1.180 (30)R4.51.573 (40)Panel cutout dimensionsmounts from backside.885(22.5)2- .142(3.6)2- .142(3.6)( ).047 (1.2).232 (5.9).024(.6).708(18)1.463 (37.2)1.317(33.5).590 (15)1.070(27.2).991(25.2).142.059 (3.6)(1.5).031 (.8).779(19.8)* Generaltolerance± .012 (.3)1.180(30)<strong>Power</strong> Entry Modules020 30 40 50 60 70 80 90Ambient Temperature (°C)Dimensions in inches (mm)Common ModeNormal ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeterInsertion Loss (dB)8060-BPF-010;-0207060-BPF-010-3-X60504060-BPF-020-3-X302010Insertion Loss (dB)8060-BPF-010;-020706060-BPF-010-X-4504030201060-BPF-020-X-400.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)807060-BPF-030;-06000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)807060-BPF-030;-060Insertion Loss (dB)605040302060-BPF-030-3-X60-BPF-060-3-XInsertion Loss (dB)605040302060-BPF-030-X-460-BPF-060-X-4101000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5827


<strong>Power</strong> Entry ModulesHigh Frequency Attenuation<strong>Power</strong> Entry Modules60-BHS SeriesFeatures■ Ideally suited for products that mustconform to FCC part 15 regulations■ Metal cased miniature filter offers high performance■ Meets over voltage of IEC 664 category IIand complies with IEC 950■ PCB mounting types available (see page 56)■ PCB mounting minimizes space and provideseconomical installation■ Excellent filtering characteristics for high frequencies■ Earth coil standard■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 29)Applications■ Digital equipment■ Personal computers and peripherals■ Measuring instruments■ Monitor and display unitsTested and found to beIAW VDE 0565 Part 3.Circuit Diagram1E2C XL 1L 2C YC Y3E4SpecificationsModel60-BHS-010-3-1160-BHS-010-3-460-BHS-010-5-1160-BHS-010-5-460-BHS-020-3-1160-BHS-020-3-460-BHS-020-5-1160-BHS-020-5-460-BHS-030-3-1160-BHS-030-3-460-BHS-030-5-1160-BHS-030-5-460-BHS-060-3-1160-BHS-060-3-460-BHS-060-5-1160-BHS-060-5-4Rated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y C X (L 1 ) (L 2 ) Rise (Max.)250VAC250VAC250VAC250VACNote: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 50gInput: Compatible with IEC-3201A2A3A6A0.35mA 2200pF ± 20%0.50mA 3300pF ± 20%0.35mA 2200pF ± 20%0.50mA 3300pF ± 20%0.35mA 2200pF ± 20%0.50mA 3300pF ± 20%0.35mA 2200pF ± 20%0.50mA 3300pF ± 20%0.1uF ± 20%.047uF ± 20%0.1uF ± 20%.047uF ± 20%0.1uF ± 20%.047uF ± 20%0.1uF ± 20%.047uF ± 20%0.1uF ± 20%.047uF ± 20%0.1uF ± 20%.047uF ± 20%0.1uF ± 20%.047uF ± 20%0.1uF ± 20%.047uF ± 20%6mH 18.3uH 30°C2.4mH 18.3uH 30°C1.2mH 18.3uH 30°C.53mH 18.3uH 45°C28 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Entry ModulesHigh Frequency Attenuation60-BHS SeriesTemperature Characteristics1.967 (50)1.573 (40).098(2.5)1.534 (39)1.389(35.3)Current (%)12010080604020.865(22)1.180 (30)R4.51.573 (40)Panel cutout dimensionsmounts from backside.885(22.5)2- .142(3.6)2- .142(3.6)1.180(30).031 (.8).779(19.8)1.180(30)<strong>Power</strong> Entry Modules020 30 40 50 60 70 80 90Ambient Temperature (°C)Dimensions in inches (mm)Common ModeNormal ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeter9060-BHS-XXX-X-119060-BHS-XXX-3-11Insertion Loss (dB)8070605040302060-BHS-010-X-1160-BHS-020-X-1160-BHS-030-X-1160-BHS-060-X-11Insertion Loss (dB)8070605040302060-BHS-010-3-1160-BHS-020-3-1160-BHS-030-3-1160-BHS-060-3-11Insertion Loss (dB)1000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)90807060504030201060-BHS-XXX-X-460-BHS-010-X-460-BHS-020-X-460-BHS-030-X-460-BHS-060-X-400.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)1000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)90807060504030201060-BHS-XXX-3-460-BHS-010-3-460-BHS-020-3-460-BHS-030-3-460-BHS-060-3-400.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5829


<strong>Power</strong> Entry ModulesBolt-in Rear TerminalsFor General Purpose Applications<strong>Power</strong> Entry Modules10-BPF SeriesFeatures■ Ideally suited for products that mustconform to FCC part 15 regulations■ Metal case offers high performance■ Meets over voltage of IEC 664 category IIand complies with IEC 950■ Uses IEC connector that meets most safety standards■ Operating temperature: -25°C to +70°C■ Compact configurationApplications■ Digital equipment■ Personal computers and peripherals■ Measuring instruments■ Monitor and display unitsCircuit DiagramC X L 1C Y1C X L 1C Y2C YC XC YC XC X L 1C YC Y3SpecificationsModelRatedVoltage(@ 50/60Hz)RatedCurrentLeakageCurrent(Max.)C YCapacitanceC XInductance(L 1 )CircuitDiagramFigureTemperatureRise(Max.)10-BPF-001-5-A10-BPF-001-5-C10-BPF-003-5-A1A3300pF2200pF3.0mH1ACA10-BPF-003-5-C3A1.5mHC10-BPF-003-5-D10-BPF-006-5-A10-BPF-006-5-C120/250VAC6A0.50mA4700pF3300pF0.01uF0.5mH21BAC30°C10-BPF-006-5-D3300pF & 0.01uF3300pF & 0.01uF1.5mH2B10-BPF-010-5-A10-BPF-010-5-D10A3300pF3300pF & 0.01uF0.01uF3300pF & 0.01uF0.5mH1.5mH13ABNote: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 45gInput: Compatible with IEC-32030SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Entry ModulesBolt-in Rear TerminalsFor General Purpose ApplicationsFigure BM3 (2X)10-BPF SeriesM3 (2X)1.6(40)2.0 (52)Figure A1.9(50)1.6(40)1.2(30)1.4 (3.5) (2X)1.6 (40)±.007.80 (20.5)+.01 -0.01.1 (28.5)+.01 -0.01.1 (28)Figure C.13 (3.5 (2X)1.25 (32)2.0 (52)2.8 (72)1.8 (46)1.4 (37)2.3 (62)<strong>Power</strong> Entry Modules.62 (16).82 (21) .25(6.5)1.5 (37.5)2.0 (51)1.6 (40)1.9 (50)1.1 (27) .07 (2)Dimensions in inches (mm)Common ModeNormal ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeter8010-BPF-001;-0038010-BPF-001;-003Insertion Loss (dB)7060504030201010-BPF-001-5-A10-BPF-001-5-C10-BPF-003-5-A10-BPF-003-5-CInsertion Loss (dB)7060504030201010-BPF-001-5-A10-BPF-001-5-C10-BPF-003-5-A10-BPF-003-5-C00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)8010-BPF-006;-010706010-BPF-006-5-A5010-BPF-006-5-C4030201010-BPF-006-5-D10-BPF-010-5-A10-BPF-010-5-DInsertion Loss (dB)807060504030201010-BPF-006;-01010-BPF-006-5-D10-BPF-010-5-A10-BPF-010-5-D10-BPF-006-5-A10-BPF-006-5-C00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5831


<strong>Power</strong> Entry ModulesBolt-in Rear TerminalsFor Medical Purpose Applications<strong>Power</strong> Entry Modules10-BPF SeriesFeatures■ Ideally suited for products that mustconform to FCC part 15 regulations■ Metal case offers high performance■ Meets over voltage of IEC 664 category IIand complies with IEC 950■ Uses IEC connector that meets most safety standards■ Operating temperature: -25°C to +70°C■ Compact configuration■ Low leakage currentApplications■ Digital equipment■ Personal computers and peripherals■ Measuring instrumentsCircuit Diagram1L 1C XE3E■ Monitor and display units24SpecificationsModelRatedVoltage(@ 50/60Hz)RatedCurrentLeakageCurrent(Max.)CapacitanceC XInductance(L 1 )CircuitDiagramFigureTemperatureRise(Max.)10-BPF-001-2-A10-BPF-003-2-A10-BPF-006-2-A120/250VAC1A10A5uA0.01uF3.0mH1.5mH0.5mH1A30°CNote: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 45gInput: Compatible with IEC-32032SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Entry ModulesBolt-in Rear TerminalsFor Medical Purpose Applications10-BPF Series1.6 (40)±.007.80 (20.5)+.01 -0.0M3 (2X)1.1 (28.5)+.01 -0.0<strong>Power</strong> Entry Modules1.4 (3.5)(2X)0.807(20.5)1.9(50)1.6(40)1.2(30)1.1 (28)Dimensions in inches (mm).63 (16).82 (21) .25(6.5)1.5 (37.5)2.0 (51)Common ModeNormal ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeter807010-BPF-001;-003;-006807010-BPF-001;-003;-006Insertion Loss (dB)60504030201010-BPF-001-2-A10-BPF-006-2-A00.1 0.2 0.5 1 2 5 10 20 5010-BPF-003-2-AInsertion Loss (dB)60504030201010-BPF-001-2-A10-BPF-003-2-A10-BPF-006-2-AFrequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5833


<strong>Power</strong> Entry ModulesSnap-in with Wire Leads<strong>Power</strong> Entry Modules60-SPL SeriesFeatures■ Ideally suited for products that mustconform to FCC part 15 regulations■ Metal cased miniature filter offers high performance■ Meets over voltage of IEC 664 category IIand complies with IEC 950■ Uses IEC connector that meets most safety standards■ Snap-in style saves labor and hardware inventory■ Wire output minimizes space and provideseconomical installation■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 35)Applications■ Digital equipment■ Personal computers and peripherals■ Measuring instruments■ Monitor and display unitsTested and found to beIAW VDE 0565 Part 3.Circuit Diagram1E2C XL 1C YC Y3E4SpecificationsModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y C X (L 1 ) Rise (Max.)60-SPL-010-3-20.35mA 2200pF ± 20%22nF ± 20%60-SPL-010-3-3250VAC1A33nF ± 20%60-SPL-010-5-20.50mA 3300pF ± 20%22nF ± 20%60-SPL-010-5-3 33nF ± 20%60-SPL-020-3-20.35mA 2200pF ± 20%22nF ± 20%60-SPL-020-3-3250VAC2A33nF ± 20%60-SPL-020-5-20.50mA 3300pF ± 20%22nF ± 20%60-SPL-020-5-3 33nF ± 20%60-SPL-030-3-20.35mA2200pF ± 20%.022uF ± 20%60-SPL-030-3-3250VAC3A3300pF ± 20%60-SPL-030-5-20.50mA2200pF ± 20%.033uF ± 20%60-SPL-030-5-3 3300pF ± 20%60-SPL-060-3-20.35mA 2200pF ± 20%22nF ± 20%60-SPL-060-3-3250VAC6A33nF ± 20%60-SPL-060-5-20.50mA 3300pF ± 20%22nF ± 20%60-SPL-060-5-3 33nF ± 20%Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 50gInput: Compatible with IEC-3206.0mH 30°C2.4mH 30°C1.2mH 30°C0.53mH 45°C34 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Entry ModulesSnap-in with Wire Leads60-SPL SeriesTemperature CharacteristicsCurrent (%)12010080604020020 30 40 50 60 70 80 90Ambient Temperature (°C)* Metal caseTin Plated.963* General tolerance(24.5)± .012 (.3) .838 (21.3)Panel cutout dimensionsTW.039 (1.0) 1.270 (32.3).047 (1.2) 1.274 (32.4).059 (1.5) 1.285 (32.5).252 (6.4)1.397(35.5)T :Panel Thickness1.612 (41)* Custom lengths available upon request.1.172 (29.8)4.719 (120)*UL 1015 AWG #18.853(21.7).236 (6)BlueGreen/YellowBrownPVC Insulated wireUL1617 AWG #22WR2Dimensions in inches (mm)<strong>Power</strong> Entry ModulesCommon ModeNormal ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeterInsertion Loss (dB)8060-SPL-010;-020706060-SPL-010-5-X504030201060-SPL-020-5-X60-SPL-020-3-X60-SPL-010-3-XInsertion Loss (dB)807060504030201060-SPL-010;-02060-SPL-010-X-460-SPL-010-X-260-SPL-020-X-460-SPL-020-X-200.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)807060504030201060-SPL-030;-06060-SPL-030-5-X60-SPL-030-3-X60-SPL-060-5-X60-SPL-060-3-XInsertion Loss (dB)807060504030201060-SPL-030;-06060-SPL-030-X-460-SPL-030-X-260-SPL-060-X-460-SPL-060-X-200.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5835


<strong>Power</strong> Entry ModulesBolt-in with Wire Leads<strong>Power</strong> Entry Modules60-BPL SeriesFeatures■ Ideally suited for products that mustconform to FCC part 15 regulations■ Metal case filter offers high performance■ Meets over voltage of IEC 664 category IIand complies with IEC 950■ Uses IEC connector that meets most safety standards■ Wire output for minimizing space useand economical installation■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 37)Applications■ Digital equipmentTested and found to beIAW VDE 0565 Part 3.Circuit Diagram1EC XL 13EC YC Y■ Personal computers and peripherals■ Measuring instruments■ Monitor and display units24SpecificationsModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y C X (L 1 ) Rise (Max.)60-BPL-010-3-20.35mA 2200pF ± 20%22nF ± 20%60-BPL-010-3-3250VAC1A33nF ± 20%60-BPL-010-5-20.50mA 3300pF ± 20%22nF ± 20%60-BPL-010-5-3 33nF ± 20%60-BPL-020-3-20.35mA 2200pF ± 20%22nF ± 20%60-BPL-020-3-3250VAC2A33nF ± 20%60-BPL-020-5-20.50mA 3300pF ± 20%22nF ± 20%60-BPL-020-5-3 33nF ± 20%60-BPL-030-3-20.35mA2200pF ± 20%.022uF ± 20%60-BPL-030-3-3250VAC3A3300pF ± 20%60-BPL-030-5-20.50mA2200pF ± 20%.033uF ± 20%60-BPL-030-5-3 3300pF ± 20%60-BPL-060-3-20.35mA 2200pF ± 20%22nF ± 20%60-BPL-060-3-3250VAC6A33nF ± 20%60-BPL-060-5-20.50mA 3300pF ± 20%22nF ± 20%60-BPL-060-5-3 33nF ± 20%Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 50gInput: Compatible with IEC-3206.0mH 30°C2.4mH 30°C1.2mH 30°C0.53mH 45°C36 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Entry ModulesBolt-in with Wire Leads60-BPL SeriesCurrent (%)Temperature Characteristics12010080604020020 30 40 50 60 70 80 90Ambient Temperature (°C).865(22)2- .142(3.6)1.967(50)R4.51.180 (30)1.573 (40) 2- .130 (3.3)Panel cutout dimensionsmounts from back side1.573(40).944 (24).830(21.1)1.160(29.5)1.612 (41).252 (6.4).837(21.3)1.172(29.8).885(22.5)2- .118 (M3)PVC Insulated wireUL1617 AWG #22* Custom lengths available upon request.R3.51.239 (31.5)1.573 (40)Panel cutout dimensionsmounts from front side4.719 (120)*.236 (6)UL1015 AWG # 18BLUEGREEN/YELLOWBROWN* General tolerance±.012 (0.3)Dimensions in inches (mm)<strong>Power</strong> Entry ModulesCommon ModeNormal ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeterInsertion Loss (dB)8070605040302060-BPL-010;-02060-BPL-020-5-X60-BPL-020-3-X60-BPL-010-5-X60-BPL-010-3-XInsertion Loss (dB)8070605040302060-BPL-010;-02060-BPL-010-X-460-BPL-010-X-260-BPL-020-X-460-BPL-020-X-2101000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)807060504030201060-BPL-030;-06060-BPL-030-5-X60-BPL-030-3-X60-BPL-060-5-X60-BPL-060-3-XInsertion Loss (dB)807060504030201060-BPL-030;-06060-BPL-030-X-460-BPL-030-X-260-BPL-060-X-260-BPL-060-X-400.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5837


<strong>Power</strong> Entry ModulesBolt-in with Wire Leads<strong>Power</strong> Entry Modules10-BPL SeriesFeatures■ Ideally suited for products that mustconform to FCC part 15 regulations■ Metal case filter offers high performance■ Meets over voltage of IEC 664 category IIand complies with IEC 950■ Uses IEC connector that meets most safety standards■ Wire output for minimizing space useand economical installation■ Operating temperature: -25°C to +70°C■ Compact configurationCircuit Diagram1L 13C YC YApplications■ Digital equipmentEC XE■ Personal computers and peripherals■ Measuring instruments■ Monitor and display units24SpecificationsModelRatedVoltage(@ 50/60Hz)RatedCurrentLeakageCurrent(Max.)C YCapacitanceC XInductance(L 1 )CircuitDiagramFigureTemperatureRise(Max.)10-BPL-001-5-B1A3.0mH10-BPL-003-5-B10-BPL-006-5-B250VAC3A6A0.50mA3300pF0.01uF1.5mH0.5mH1A30°CNote: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 50gInput: Compatible with IEC-32038SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Entry ModulesBolt-in with Wire Leads10-BPL SeriesM3 (2X)Figure A1.4 (3.5)(2X)1.6 (40)±.007.80 (20.5)+.01 -0.01.1 (28.5)+.01 -0.0<strong>Power</strong> Entry Modules1.9(50)1.6(40)1.2(30)1.1 (28).63 (16).82 (21) .25(6.5)1.5 (37.5)2.0 (51)Dimensions in inches (mm)Common ModeNormal ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeterInsertion Loss (dB)8010-BPL-001;-003;-0067010-BPL-003-5-B10-BPL-001-5-B60504030201010-BPL-006-5-BInsertion Loss (dB)807060504030201010-BPL-001;-003;-00610-BPL-001-5-B10-BPL-003-5-B10-BPL-006-5-B00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5839


<strong>Power</strong> Entry ModulesSnap-in Mount<strong>Power</strong> Entry Modules60-SPR & SPS SeriesFeaturesTested and found to beIAW VDE 0565 Part 3.■ Ideally suited for products that mustconform to FCC part 15 regulations■ Metal cased miniature filter offers high performance■ Meets over voltage of IEC 664 category IIand complies with IEC 950■ Uses IEC connector that meets most safety standards■ Snap-in style saves labor and hardware inventory■ Solder lug and fast-on tab terminations available■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 41)■ UL approved low leakage version also availableCircuit Diagram1L 13C YC YApplications■ Digital equipment■ Personal computers and peripherals■ Measuring instruments■ Monitor and display unitsE2C XE4SpecificationsModel*Rated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y C X (L 1 ) Rise (Max.)60-XXX-010-3-20.35mA 2200pF ± 20%.022uF ± 20%60-XXX-010-3-4250VAC1A.047uF ± 20%6.0mH 30°C60-XXX-010-5-20.50mA 3300pF ± 20%.022uF ± 20%60-XXX-010-5-4 .047uF ± 20%60-XXX-020-3-20.35mA 2200pF ± 20%.022uF ± 20%60-XXX-020-3-4250VAC2A.047uF ± 20%2.4mH 30°C60-XXX-020-5-20.50mA 3300pF ± 20%.022uF ± 20%60-XXX-020-5-4 .047uF ± 20%60-XXX-030-3-20.35mA 2200pF ± 20%.022uF ± 20%60-XXX-030-3-4250VAC3A.047uF ± 20%1.2mH 30°C60-XXX-030-5-20.50mA 3300pF ± 20%.022uF ± 20%60-XXX-030-5-4 .047uF ± 20%60-XXX-060-3-20.35mA 2200pF ± 20%.022uF ± 20%60-XXX-060-3-4250VAC6A.047uF ± 20%0.53mH 45°C60-XXX-060-5-20.50mA 3300pF ± 20%.022uF ± 20%60-XXX-060-5-4 .047uF ± 20%60-XXX-100-3-2250VAC10A0.35mA 2200pF ± 20%.022uF ± 20% 0.26mH 45°C60-XXX-100-5-2 0.50mA 3300pF ± 20%60-SPR-150-3-11 250VAC 15A 0.35mA 2200pF ± 20% .01uF ± 20% 0.15mH 45°CNote: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 45gInput: Compatible with IEC-320* Substitute SPR or SPS for XXX60-SPR - Fast-on terminals60-SPS - Solder lug terminals40 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Entry ModulesSnap-in Mount60-SPR & SPS SeriesTemperature CharacteristicsCurrent (%)12010080604020Panel cutout dimensionsTW.039 (1.0) 1.270 (32.3).047 (1.2) 1.274 (32.4).059 (1.5) 1.285 (32.5).252 (6.4).963(24.5)1.395(35.5)T: Panel Thickness2.033 (51.7)1.805 (45.9)1.418 (35.9).837(21.3).157(4).853(21.7)1.172(29.8)Panel cutout dimensionsfor 1.0t chassisSolder Lug2 X 3 holeWR2* Standard terminalFast-on tab #250available asSPR series2.096 (53.3)* General tolerance± .012 (0.3)<strong>Power</strong> Entry Modules020 30 40 50 60 70 80 90Ambient Temperature (°C)Solder lugs shown. Also available in fast-ons.Dimensions in inches (mm)Common ModeNormal ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeterInsertion Loss (dB)8060-SPX-010;-020;-0307060-SPX-010-5-X60504060-SPX-020-5-X3060-SPX-030-5-X2010Insertion Loss (dB)8060-SPX-010;-020;-0307060-SPX-010-X-4605060-SPX-020-X-44030201060-SPX-030-X-400.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)8060-SPX-060;-1008060-SPX-060;-100Insertion Loss (dB)70605040302060-SPX-60-5-X60-SPX-100-5-XInsertion Loss (dB)70605040302060-SPX-060-X-460-SPX-060-X-260-SPX-100-X-2101000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5841


Fused Filtered<strong>Power</strong> Entry ModulesFor General Purpose Applications64-65-BFF/64-65-BFS SeriesFused Filtered<strong>Power</strong> Entry ModulesFeaturesTested and found to beIAW VDE 0565 Part 3.■ North American and Metric fuseholders available■ Fuse holder provides effective <strong>EMI</strong> suppressionof common and differential mode■ Suitable for products that must conformto FCC and FTZ requirements■ Meets over voltage category II of IEC 664and complies with IEC 950■ Fast-on terminals or solder lug terminals■ Metal case provides effective <strong>EMI</strong> shielding■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 43)Applications■ Computers and peripheral equipment■ Electronic equipment■ Digital equipment■ Measuring and testing instruments■ Telecommunications equipmentCircuit DiagramLENL 1R C XC YC YLENSpecificationsModel*64-XXX-020-3-1164-XXX-020-5-1164-XXX-020-3-1264-XXX-020-5-1264-XXX-040-3-1164-XXX-040-5-1164-XXX-040-3-1264-XXX-040-5-1264-XXX-060-3-1164-XXX-060-5-1164-XXX-060-3-1264-XXX-060-5-1265-XXX-020-3-1165-XXX-020-5-1165-XXX-020-3-1265-XXX-020-5-1265-XXX-040-3-1165-XXX-040-5-1165-XXX-040-3-1265-XXX-040-5-1265-XXX-060-3-1165-XXX-060-5-1165-XXX-060-3-1265-XXX-060-5-12Rated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y C X (L 1 ) Rise (Max.)250VAC250VAC250VAC125VAC125VAC125VAC2A4A6A2A4A6ANote: Test Voltage 1500VAC one minute, line to groundInsulation Resistance: 300 MΩ min. at 500VDCF(S) = Fast-on or (Solder lug terminals)0.35mA0.50mA0.35mA0.50mA0.35mA0.50mA0.35mA0.50mA0.35mA0.50mA0.35mA0.50mA0.20mA0.25mA0.20mA0.25mA0.20mA0.25mA0.20mA0.25mA0.20mA0.25mA0.20mA0.25mA2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%2200pF ± 20%3300pF ± 20%Voltage Drop: 1V max. at rated currentWeight: 78gInlet: Compatible with IEC-3200.1uF0.22uF0.1uF0.22uF0.1uF0.22uF0.1uF0.22uF0.1uF0.22uF0.1uF0.22uF6.5mH4.2mH1.6mH6.5mH4.2mH1.6mH* Substitute BFF or BFS for XXXBFF - Fast-on terminalsBFS - Solder lug terminals42 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5840°C45°C45°C40°C45°C45°C


Fused Filtered<strong>Power</strong> Entry ModulesFor General Purpose Applications64-65-BFF/64-65-BFS SeriesTemperature CharacteristicsCurrent (%)12010080604020020 30 40 50 60 70 80 90Ambient Temperature (°C)Dimensions64/65-BFF Series1.376(35)1.738 (44.2)1.101 (28)Fuse cover1.298(33) +.0082 - .13 -.004(2 - 3.3 +0.2-0.1)Hole1.416±.008(36±0.2)0.252 (6.4)* Alternate Terminal for 64/65-BFS-Solder Lug Terminal2.249 (L:57.2)0.158(4.0).098 (2.5)2.32 (59)1.616 (41.1) 1.14(29)Fast-on tab#250t= .031 (0.8)* General Tolerance:±.020 (0.5)* Metal Case1.29(32.8)Dimensions in inches (mm)Fused Filtered<strong>Power</strong> Entry ModulesCommon ModeNormal ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeterInsertion Loss (dB)0.50 mA Leakage Versions9080702 Amp6050406 Amp30204 Amp10Insertion Loss (dB)9080706050403020100.50 mA Leakage Versions2 Amp6 Amp4 Amp00.1 0.2 0.5 1 2 5 10 20 5000.1 0.2 0.5 1 2 5 10 20 50Insertion Loss (dB)90Frequency (MHz)0.35 mA Leakage Versions80702 Amp6050406 Amp30204 Amp10Insertion Loss (dB)90Frequency (MHz)0.35 mA Leakage Versions80702 Amp6050406 Amp304 Amp201000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5843


Fused Filtered<strong>Power</strong> Entry ModulesFused Filtered<strong>Power</strong> Entry ModulesFor Medical or General Purpose Applications66-67-BFF/66-67-BFS SeriesFeaturesTested and found to beIAW VDE 0565 Part 3.■ Metric and North American fuseholders available■ Fuse holder provides effective <strong>EMI</strong> suppressionof common and differential mode■ Suitable for products that must conformto FCC and FTZ requirements■ Meets over voltage category II of IEC 664and complies with IEC 950■ Fast-on terminations or solder lug terminations■ Metal case provides effective <strong>EMI</strong> shielding■ Provides susceptibility protection without the leakagecurrent associated with line-to-ground capacitance■ Reduces the line to ground capacitance in orderto meet patient care requirements■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 45)SpecificationsApplications■ Medical equipment■ Electronic equipment■ Digital equipment■ Industrial equipmentCircuit Diagrams66/67-BFF(S)-XXX-1-X FilterLINELEN■ Telecommunications equipment■ Measuring and testing instruments■ Personal computersand peripheralsLR C XL 1R C XL 1 C YENLOADLINE66/67-BFF(S)-XXX-0-X and66/67-BFF(S)-XXX-4-X <strong>Filters</strong>LENC YLENLOADModel*Rated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y C X (L 1 ) Rise (Max.)66-XXX-020-1-1166-XXX-020-1-1266-XXX-020-0-1166-XXX-020-4-1166-XXX-020-0-1266-XXX-020-4-1266-XXX-040-1-1166-XXX-040-1-1266-XXX-040-0-1166-XXX-040-4-11250VAC4A66-XXX-040-0-1266-XXX-040-4-1266-XXX-060-1-1166-XXX-060-1-1266-XXX-060-0-1166-XXX-060-4-11250VAC6A66-XXX-060-0-1266-XXX-060-4-1267-XXX-020-1-1167-XXX-020-1-1267-XXX-020-0-1167-XXX-020-4-11125VAC2A67-XXX-020-0-1267-XXX-020-4-1267-XXX-040-1-1167-XXX-040-1-1267-XXX-040-0-1167-XXX-040-4-11125VAC4A67-XXX-040-0-1267-XXX-040-4-1267-XXX-060-1-1167-XXX-060-1-1267-XXX-060-0-1167-XXX-060-4-11125VAC6A67-XXX-060-0-1267-XXX-060-4-12Note: Test Voltage 1500VAC one minute, line to groundInsulation Resistance: 300 MΩ min. at 500VDCF(S) = Fast-on or (Solder lug terminals)0.01mAnone0.1uF0.22uF250VAC 2A0.075mA 330pF ± 20%0.1mA 470pF ± 20%0.1uF6.5mH40°C0.075mA 330pF ± 20%0.1mA 470pF ± 20%0.22uF0.01mAnone0.075mA0.1mA0.075mA0.1mA0.01mA0.075mA0.1mA0.075mA0.1mA0.005mA0.035mA0.05mA0.035mA0.05mA0.005mA0.035mA0.05mA0.035mA0.05mA0.005mA0.035mA0.05mA0.035mA0.05mA330pF ± 20%470pF ± 20%330pF ± 20%470pF ± 20%Voltage Drop: 1V max. at rated currentWeight: 78gInlet: Compatible with IEC-320* Substitute BFF or BFS for XXXBFF - Fast-on terminalsBFS - Solder lug terminals44 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58none330pF ± 20%470pF ± 20%330pF ± 20%470pF ± 20%none330pF ± 20%470pF ± 20%330pF ± 20%470pF ± 20%none330pF ± 20%470pF ± 20%330pF ± 20%470pF ± 20%none330pF ± 20%470pF ± 20%330pF ± 20%470pF ± 20%0.1uF0.22uF0.1uF0.22uF0.1uF0.22uF0.1uF0.22uF0.1uF0.22uF0.1uF0.22uF0.1uF0.22uF0.1uF0.22uF0.1uF0.22uF0.1uF0.22uF4.2mH1.6mH6.5mH4.2mH1.6mH45°C45°C40°C45°C45°C


Fused Filtered<strong>Power</strong> Entry ModulesFor Medical or General Purpose Applications66-67-BFF/66-67-BFS SeriesTemperature CharacteristicsCurrent (%)12010080604020020 30 40 50 60 70 80 90Ambient Temperature (°C)Dimensions66-67-BFF/66-67-BFS Series1.376(35)1.738 (44.2)1.101 (28)Fuse cover1.298(33) +.0082 - .13 -.004(2 - 3.3 +0.2-0.1)Hole1.416±.008(36±0.2)0.252 (6.4)* Alternate Terminal for 66/67-BFS-Solder Lug Terminal2.249 (L:57.2)0.158(4.0).098 (2.5)2.32 (59)1.616 (41.1) 1.14(29)Fast-on tab#250t= .031 (0.8)* General Tolerance:±.020 (0.5)* Metal CaseDimensions in inches (mm)1.29(32.8)Fused Filtered<strong>Power</strong> Entry ModulesCommon ModeNormal ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeterInsertion Loss (dB)0.01 mA Leakage Current90807060502 Amp4030204 Amp 6 Amp10Insertion Loss (dB)0.01 mA Leakage Current90807060502 Amp4 Amp4030206 Amp10Insertion Loss (dB)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)0.075 and 0.1 mA Leakage Current90807060502 Amp4030204 Amp 6 Amp10Insertion Loss (dB)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)0.075 and 0.1 mA Leakage Current90807060502 Amp40304 Amp206 Amp1000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5845


Switched and Fused Filtered<strong>Power</strong> Entry ModulesFor General Purpose ApplicationsSwitched and Fused Filtered<strong>Power</strong> Entry Modules64-65-BSF/64-65-SSF SeriesFeaturesTested and found to beIAW VDE 0565 Part 3.■ North American and Metric fuseholders available■ Fuse holder and double pole power ON/OFF switchprovided in a convenient/compact package■ Suitable for products that must conformto FCC and FTZ requirements■ Meets over voltage category II of IEC 664and complies with IEC 950■ Metal case provides effective <strong>EMI</strong> shielding■ Easy access fuse drawer with space for spare fuse■ Flange-mounted or snap-in styles availablefor quick mounting■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 47)SpecificationsModel*64-XXX-020-3-1264-XXX-020-3-0464-XXX-020-3-1464-XXX-020-3-0664-XXX-020-5-12250VAC2A64-XXX-020-5-0464-XXX-020-5-1464-XXX-020-5-0664-XXX-040-3-1264-XXX-040-3-0464-XXX-040-3-1464-XXX-040-3-0664-XXX-040-5-12250VAC4A64-XXX-040-5-0464-XXX-040-5-1464-XXX-040-5-0664-XXX-060-3-1264-XXX-060-3-0464-XXX-060-3-1464-XXX-060-3-0664-XXX-060-5-12250VAC6A64-XXX-060-5-0464-XXX-060-5-1464-XXX-060-5-0665-XXX-020-3-1265-XXX-020-3-0465-XXX-020-3-1465-XXX-020-3-0665-XXX-020-5-12125VAC2A65-XXX-020-5-0465-XXX-020-5-1465-XXX-020-5-0665-XXX-040-3-1265-XXX-040-3-0465-XXX-040-3-1465-XXX-040-3-0665-XXX-040-5-12125VAC4A65-XXX-040-5-0465-XXX-040-5-1465-XXX-040-5-0665-XXX-060-3-1265-XXX-060-3-0465-XXX-060-3-1465-XXX-060-3-0665-XXX-060-5-12125VAC6A65-XXX-060-5-0465-XXX-060-5-1465-XXX-060-5-06Note: Test Voltage 1500VAC one minute, line to groundInsulation Resistance: 300 MΩ min. at 500VDCB(S) = Bolt-in terminals or (Snap-in terminals)Applications■ Computers andperipheral equipment■ Electronic equipmentVoltage Drop: 1V max. at rated currentWeight: 130gInlet: Compatible with IEC-320Circuit DiagramLENRCX■ Digital equipment■ Measuring and testing instruments■ Telecommunications equipmentRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y C X1 C X2 (L 1 ) Rise (Max.)0.35mA0.50mA0.35mA0.50mA0.35mA0.50mA0.35mA0.50mA0.35mA0.50mA0.35mA0.50mA2200pF3300pF2200pF3300pF2200pF2200pF3300pF2200pF3300pF2200pF0.22uF0.47uF0.22uF0.47uF0.22uF0.47uF0.22uF0.47uF0.22uF0.47uF0.22uF0.47uF0.22uF0.47uF0.22uF0.47uF0.22uF0.47uF0.22uF0.47uF0.22uF0.47uF0.22uF0.47uFCXCYCYNONE0.22uFNONE0.47uF 10.5mHNONE0.22uFNONE0.47uFNONE0.22uFNONE0.47uF4.2mHNONE0.22uFNONE0.47uFNONE0.22uFNONE0.47uF1.6mHNONE0.22uFNONE0.47uFNONE0.22uFNONE0.47uF10.5mHNONE0.22uFNONE0.47uFNONE0.22uFNONE0.47uF4.2mHNONE0.22uFNONE0.47uFNONE0.22uFNONE0.47uF1.6mHNONE0.22uFNONE0.47uF* Substitute BSF or SSF for XXXBSF - Bolt-in switched and fusedSSF - Snap-in switched and fusedLEN45°C45°C45°C45°C45°C45°C46 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


Temperature Characteristics120Switched and Fused Filtered<strong>Power</strong> Entry ModulesFor General Purpose ApplicationsCurrent (%)10080604020020 30 40 50 60 70 80 90Ambient Temperature (°C)Dimensions64/65-BSF Series2.556(65).248(6.3)2.348(59.7) Ø.142(3.6)1.573(40.±0.2)1.947 (49.5)1.101 (28)1.573 (40±0.2).3341.16± 0(29.5± 0.50 )2.399 (61)2 - .142(3.6) HoleR .059(1.5)1.526 (38.8)Panel cutoutdimensionmount fromback side2.273 (57.8) 1.133(28.8)Fast-on Tab #250t= .031 (0.8)2.340(59.5)Dimensions in inches (mm)64/65-SSF Series2.556(65)2.348(59.7)1.313 (33.4)1.101 (28).248(6.3)R .079(2.0)A+.021.16-0(29.5 +0.5-0 )1.514 (38.8)Fast-on tab #250t= .031 (0.8)2.273 (57.8)Panel cutout dimensionmount from back side1.133(28.8)2.340(59.5)Thickness of PanelA.031 (0.8t) 2.430 (61.8±0.1).039 (1.0t) 2.446 (62.2±0.1).047 (1.2t) 2.462 (62.6±0.1).059 (1.5t) 2.470 (62.8±0.1).071 (1.8t) 2.473 (62.9±0.1).079 (2.0t) 2.477 (63.0±0.1)* General Tolerance± .039 (1.0)* Metal CaseSwitched and Fused Filtered<strong>Power</strong> Entry ModulesCommon ModeNormal ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeterInsertion Loss (dB)0.35 mA Leakage Versions9080702 Amp6050404 Amp306 Amp2010Insertion Loss (dB)100908070605040302064/65-B(S)SF-*-*-02(04,06)2 Amp4 Amp6 AmpInsertion Loss (dB)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)0.50 mA Leakage Versions9080702 Amp6050404 Amp306 Amp201000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)100908070605040302064/65-B(S)SF-*-*-11(12,14)4 Amp6 Amp2 Amp00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5847


Switched and Fused Filtered<strong>Power</strong> Entry ModulesFor Medical or General Purpose ApplicationsSwitched and Fused Filtered<strong>Power</strong> Entry Modules66-67-BSF/66-67-SSF SeriesFeatures■ Metric and North American fuse holders available■ Fuse holder and a double pole power ON/OFF switchprovides a convenient/compact package■ Suitable for products that must conformto FCC and FTZ requirements■ Meets over voltage category II of IEC 664and complies with IEC 950■ Provides susceptibility protection without the leakagecurrent associated with line-to-ground capacitors■ Designed to meet requirements for non-patientand patient care equipment■ Metal case provides effective <strong>EMI</strong> shielding■ Easy access fuse drawer - space for spare fuse■ Flange-mounted or snap-in styles availablefor quick mounting■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 49)SpecificationsTested and found to beIAW VDE 0565 Part 3Applications■ Medical equipment■ Industrial equipment■ Telecommunications equipment■ Measuring and testing instrumentsCircuit DiagramNote: C Y1 and C Y2 capacitorsomitted on 66/67B(S)F-XXX-1-X <strong>Filters</strong>LINELEN■ Digital equipment (includingswitching power supplies)■ General purpose filter forsusceptibility or high frequency“clean up” applicationsRCX1L1CX2CY1CY2LENLOADRated Rated Leakage Temp.Model* Voltage Current Current Capacitance Induct. Rise50/60Hz (Max.) C Y C X1 C X2 (L 1 ) (Max.)66-XXX-020-0-1266-XXX-020-0-0466-XXX-020-0-1466-XXX-020-0-0666-XXX-020-1-1266-XXX-020-1-0466-XXX-020-1-1466-XXX-020-1-0666-XXX-020-4-1266-XXX-020-4-0466-XXX-020-4-1466-XXX-020-4-0666-XXX-040-0-1266-XXX-040-0-0466-XXX-040-0-1466-XXX-040-0-0666-XXX-040-1-1266-XXX-040-1-0466-XXX-040-1-1466-XXX-040-1-0666-XXX-040-4-1266-XXX-040-4-0466-XXX-040-4-1466-XXX-040-4-0666-XXX-060-0-1266-XXX-060-0-0466-XXX-060-0-1466-XXX-060-0-0666-XXX-060-1-1266-XXX-060-1-0466-XXX-060-1-1466-XXX-060-1-0666-XXX-060-4-1266-XXX-060-4-0466-XXX-060-4-1466-XXX-060-4-06250VAC2A4A6A0.22uF.075mA 330pF0.47uF0.22uF.01mA NONE0.47uF0.1mA 470pF.075mA 330pF0.22uF0.47uF0.22uF0.47uF0.22uF.01mA NONE0.47uF.01mA 470pF.075mA 330pF0.22uF0.47uF0.22uF0.47uF0.22uF.01mA NONE0.47uF0.1mA 470pF0.22uF0.47uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNote: Test Voltage: 1500VAC one minute, line to groundInsulation Resistance: 300 MΩ min. at 500VDCVoltage Drop: 1V max. at rated current10.5mH4.2mH1.6mH40°C45°CRated Rated Leakage Temp.Model* Voltage Current Current Capacitance Induct. Rise50/60Hz (Max.) C Y C X1 C X2 (L 1 ) (Max.)67-XXX-020-0-1267-XXX-020-0-0467-XXX-020-0-1467-XXX-020-0-0667-XXX-020-1-1267-XXX-020-1-0467-XXX-020-1-1467-XXX-020-1-0667-XXX-020-4-1267-XXX-020-4-0467-XXX-020-4-1467-XXX-020-4-0667-XXX-040-0-1267-XXX-040-0-0467-XXX-040-0-1467-XXX-040-0-0667-XXX-040-1-1267-XXX-040-1-0467-XXX-040-1-1467-XXX-040-1-0667-XXX-040-4-1267-XXX-040-4-0467-XXX-040-4-1467-XXX-040-4-0667-XXX-060-0-1267-XXX-060-0-0467-XXX-060-0-1467-XXX-060-0-0667-XXX-060-1-1267-XXX-060-1-0467-XXX-060-1-1467-XXX-060-1-0667-XXX-060-4-1267-XXX-060-4-0467-XXX-060-4-1467-XXX-060-4-06Weight: 130gInlet: Compatible with IEC-320B(S) = Bolt-in terminals or (Snap-in terminals)* Substitute BSF or SSF for XXXBSF - Bolt-In Switched and FusedSSF - Snap-In Switched and Fused48 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58125VAC2A4A6A0.22uF0.04mA 330pF0.47uF0.22uF.005mA NONE0.47uF0.05mA 470pF0.04mA 330pF0.22uF0.47uF0.22uF0.47uF0.22uF.005mA NONE0.47uF0.05mA 470pF0.04mA 330pF0.22uF0.47uF0.22uF0.47uF0.22uF.005mA NONE0.47uF0.05mA 470pF0.22uF0.47uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uFNONE0.22uF10.5mH4.2mH1.6mH40°C45°C


Temperature Characteristics120Switched and Fused Filtered<strong>Power</strong> Entry ModulesFor Medical or General Purpose ApplicationsDimensions66/67-BSF Series2.556(65).248(6.3)2.348(59.7) Ø.142(3.6)1.573(40.±0.2)1.947 (49.5)1.101 (28)1.573 (40±0.2)+.021.16-0(29.5 +0.5-0 )2.399 (61)2 - .142(3.6) HoleR .059(1.5)1.526 (38.8)Panel cutoutdimensionmount fromback side2.273 (57.8) 1.133(28.8)Fast-on Tab #250t= .031 (0.8)2.340(59.5)Dimensions in inches (mm)2.556(65)2.348(59.7)Current (%)1.313 (33.4)1.101 (28)1008060402066/67-SSF Series0.248(6.3)R .079(2.0)A+.021.16-0(29.5 +0.5-0 )20 30 40 50 60 70 80 90Ambient Temperature (°C)1.514 (38.8)Fast-on tab #250t= .031 (0.8)2.273 (57.8)Panel cutout dimensionmount from back side1.133(28.8)2.340(59.5)Thickness of PanelA.031 (0.8t) 2.430 (61.8±0.1).039 (1.0t) 2.446 (62.2±0.1).047 (1.2t) 2.462 (62.6±0.1).059 (1.5t) 2.470 (62.8±0.1).071 (1.8t) 2.473 (62.9±0.1).079 (2.0t) 2.477 (63.0±0.1)* General Tolerance± .039 (1.0)* Metal CaseSwitched and Fused Filtered<strong>Power</strong> Entry ModulesCommon ModeNormal ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeterInsertion Loss (dB)0.01 mA Leakage Current908070602 Amp504030204 Amp 6 Amp10Insertion Loss (dB)0.01 mA Leakage Current908070602 Amp5040304 Amp206 Amp10Insertion Loss (dB)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)0.075 and 0.1 mA Leakage Current908070602 Amp504030204 Amp6 Amp10Insertion Loss (dB)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)0.075 and 0.1 mA Leakage Current908070602 Amp50404 Amp306 Amp201000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5849


Switched and Fused Filtered<strong>Power</strong> Entry ModulesDual Fuse for European Applications68-BSF SeriesSwitched and Fused Filtered<strong>Power</strong> Entry ModulesFeatures■ Dual fuse for European applications■ Fuse holder and double pole power ON/OFF switchprovides a convenient/compact package■ Suitable for products that must conformto FCC and FTZ requirements■ Meets over voltage category II of IEC 664and complies with IEC 950■ Metal case provides effective <strong>EMI</strong> shielding■ IEC connector meets the safety standards of mostcertifying agencies■ Easy access fuse drawer■ Flange-mounted■ UL, CSA, and SEMKO approvedLENCircuit DiagramFUSEC X1R 1SWL 1L 2C X2C Y1C Y2LEN■ Designed to be in accordance with VDE 0565, part 3■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 51)Applications■ Computers and peripheral equipment■ Electronic equipment■ Digital equipment■ Measuring and testing instruments■ Telecommunications equipmentSpecificationsModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y1 C Y2 C X1 C X2 (L 1 ) Rise (Max.)68-BSF-020-3-012A0.1uF 0.1uF10.5mH68-BSF-020-3-04 0.22uF 0.22uF68-BSF-040-3-01250VAC 4A 0.35mA 2200pF 2200pF 0.1uF 0.1uF 4.2mH 45°C68-BSF-040-3-04 0.22uF 0.22uF68-BSF-060-3-016A0.1uF 0.1uF1.6mH68-BSF-060-3-04 0.22uF 0.22uFNote: Test Voltage 1500VAC one minute, line to groundInsulation Resistance: 300 MΩ min. at 500VDCVoltage Drop: 1V max. at rated currentWeight: 130gInlet: Compatible with IEC-320B(S) = Bolt-in terminals or (Snap-in terminals)50 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


Switched and Fused Filtered<strong>Power</strong> Entry ModulesDual Fuse for European Applications68-BSF SeriesCurrent (%)1.947 (49.5)Temperature Characteristics.24812010080604020020 30 40 50 60 70 80 90Ambient Temperature (°C)2.556(65)1.101 (28)(6.3)2.348(59.7) Ø.142(3.6)1.573(40.±0.2)1.573 (40±0.2)+.021.16-0(29.5 +0.5-0 )2.399 (61)2 - .142(3.6) HoleR .059(1.5)1.526 (38.8)Panel cutoutdimensionmount fromback side2.273 (57.8) 1.133(28.8)Fast-on Tab #250t= .031 (0.8)2.340(59.5)Dimensions in inches (mm)Switched and Fused Filtered<strong>Power</strong> Entry ModulesCommon ModeNormal ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeter9010080907080Insertion Loss (dB)6050403020106 Amp4 Amp2 AmpInsertion Loss (dB)7060504030206 Amp2 Amp4 Amp00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5851


PCB <strong>Power</strong> <strong>Filters</strong>Miniature Printed Circuit BoardPCB <strong>Power</strong> <strong>Filters</strong>61-MPC SeriesFeatures■ Miniature general purpose PCB mounted filter■ Requires minimal PCB real estate space■ Low cost■ Designed for two wire cord systems■ For three wire cord systems, Y capacitorscan be attached externally■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 53)Applications■ Personal computers and peripherals■ Digital equipment■ Measuring instruments and medical equipment■ TV & VCR monitors and display units■ Home appliancesTested and found to beIAW VDE 0565 Part 3Circuit Diagram1 3L 1C X1C X12 4SpecificationsModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C X1 C X2 (L 1 ) Rise (Max.)61-MPC-010-1-11 1A 11mH61-MPC-016-1-111.6A6.0mH250VAC0.1mA 0.01uF 0.01uF61-MPC-025-1-11 2.5A 2.4mH61-MPC-036-1-11 3.6A 1.2mHNote: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 17.5g40°C52 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


PCB <strong>Power</strong> <strong>Filters</strong>Miniature Printed Circuit Board61-MPC Series4 — .031 (.8)1234.767 (19.5).551 (14).767 (19.5).059 (1.5).590 (15)Dimensions in inches (mm)1.239 (31.5).354(9)Insertion Loss (dB)Common ModeCommonmode withY cap.(Test circuit 1)(Test circuit 2)807060504030201061-MPCOscillator50ΩOscillator50Ω61-MPC-010-1-1161-MPC-036-1-111 3Filter2 41 3Filter2 461-MPC-025-1-1150Ω50Ω61-MPC-016-1-1150ΩLevelMeter50ΩLevelMeterY Cap2 X 3300pFTemperature CharacteristicsCurrent (%)12010080604020Normal Mode(Test circuit 3)00 30 40 50 60 70 80 90 100Ambient Temperature (°C)Oscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeterPCB <strong>Power</strong> <strong>Filters</strong>00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)8061-MPC7061-MPC-010-1-116050403061-MPC-016-1-112061-MPC-025-1-111061-MPC-036-1-1100.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)8061-MPC70605061-MPC-010-1-114061-MPC-016-1-113061-MPC-025-1-112061-MPC-036-1-111000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5853


<strong>Power</strong> Entry ModulesBolt-in Right Angle Terminalsfor PCB ApplicationsPCB <strong>Power</strong> <strong>Filters</strong>60-BPP SeriesFeatures■ Ideally suited for products that mustconform to FCC part 15 regulations■ Metal case offers high performance■ Meets over voltage of IEC 664 category IIand complies with IEC 950■ Uses IEC connector that meets most safety standardsSolder lug, Fast-on tab styles available (see page 26)■ PCB mounting style minimizes space and provideseconomical installation■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 55)■ UL approved low leakage version also availableApplications■ Digital equipment■ Personal computers and peripherals■ Measuring instruments■ Monitor and display unitsTested and found to beIAW VDE 0565 Part 3Circuit Diagram1E2C XL 1C YC Y3E4SpecificationsModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y C X (L 1 ) Rise (Max.)60-BPP-010-3-260-BPP-010-3-460-BPP-010-5-260-BPP-010-5-41A0.35mA0.50mA2200pF3300pF0.022uF0.047uF0.022uF0.047uF6.0mH60-BPP-020-3-260-BPP-020-3-460-BPP-020-5-260-BPP-020-5-460-BPP-030-3-260-BPP-030-3-460-BPP-030-5-260-BPP-030-5-4250VAC2A3A0.35mA0.50mA0.35mA0.50mA2200pF3300pF2200pF3300pF0.022uF0.047uF0.022uF0.047uF0.022uF0.047uF0.022uF0.047uF2.4mH 30°C1.2mH60-BPP-060-3-260-BPP-060-3-460-BPP-060-5-260-BPP-060-5-46A0.35mA0.50mA2200pF3300pF0.022uF0.047uF0.022uF0.047uF0.53mH 45°CNote: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 50gInput: Compatible with IEC-32054 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Entry ModulesBolt-in Right Angle Terminalsfor PCB Applications60-BPP SeriesTemperature Characteristics12010060-BPPPCBMountingType1.967 (50)1.573 (40).885(22.5).098 (2.5)1.463 (37.2)1.317(33.5).590 (15).991(25.2)* Generaltolerance± .012 (.3)Current (%)806040.865(22)1.180 (30)R4.51.573 (40)2- .142(3.6)2- .142(3.6).047 (1.2).232 (5.9).024(.6).708(18)1.070(27.2).142.059 (3.6)(1.5).031 (.8).779(19.8)1.180(30)20020 30 40 50 60 70 80 90Ambient Temperature (°C)Panel cutout dimensionsmounts from backsideDimensions in inches (mm)PCB <strong>Power</strong> <strong>Filters</strong>Common ModeNormal ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeterInsertion Loss (dB)8060-BPP-010;-0207060-BPP-010-3-X60504060-BPP-020-3-X302010Insertion Loss (dB)8060-BPP-010;-020706060-BPP-010-X-4504030201060-BPP-020-X-400.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)807060-BPP-030;-06000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)807060-BPP-030;-060Insertion Loss (dB)605040302060-BPP-030-3-X60-BPP-060-3-XInsertion Loss (dB)605040302060-BPP-030-X-460-BPP-060-X-4101000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5855


<strong>Power</strong> Entry ModulesHigh Frequency AttenuationBolt-in for PCB ApplicationsPCB <strong>Power</strong> <strong>Filters</strong>60-BHP SeriesFeatures■ Ideally suited for products that mustconform to FCC part 15 regulations■ Metal cased filter offers high performance■ Meets over voltage of IEC 664 category IIand complies with IEC 950■ Solder lug, Fast-on tab styles available (see page 28)■ PCB mounting minimizes space and provideseconomical installation■ Excellent filtering characteristics for high frequencies■ Earth coil standard■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 57)Applications■ Digital equipment■ Personal computers and peripherals■ Measuring instruments■ Monitor and display unitsTested and found to beIAW VDE 0565 Part 3Circuit Diagram1E2C XL 1L 2C YC Y3E4SpecificationsModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y C X (L 1 ) (L 2 ) Rise (Max.)60-BHP-010-3-1160-BHP-010-3-460-BHP-010-5-1160-BHP-010-5-460-BHP-020-3-1160-BHP-020-3-460-BHP-020-5-1160-BHP-020-5-460-BHP-030-3-1160-BHP-030-3-460-BHP-030-5-1160-BHP-030-5-460-BHP-060-3-1160-BHP-060-3-460-BHP-060-5-1160-BHP-060-5-4250VACNote: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 50gInput: Compatible with IEC-3201A2A3A6A0.35mA 2200pF±20% 0.1uF±20%.047uF±20%0.50mA 3300pF±20% 0.1uF±20%.047uF±20%0.35mA0.50mA0.35mA0.50mA0.35mA0.50mA2200pF±20%3300pF±20%2200pF±20%3300pF±20%2200pF±20%3300pF±20%0.1uF±20%.047uF±20%0.1uF±20%.047uF±20%0.1uF±20%.047uF±20%0.1uF±20%.047uF±20%0.1uF±20%.047uF±20%0.1uF±20%.047uF±20%6mH2.4mH 30°C18.3 uH1.2mH0.53mH 45°C56 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Entry ModulesHigh Frequency AttenuationBolt-in for PCB Applications60-BHP SeriesTemperature CharacteristicsCurrent (%)12010080604020020 30 40 50 60 70 80 90Ambient Temperature (°C)Common Mode60-BHPPCBMountingType.865(22)1.967 (50)1.573 (40)1.180 (30)R4.51.573 (40)Panel cutout dimensionsmounts from backsideNormal Mode.885(22.5)2- .142(3.6)2- .142(3.6).098(2.5).047 (1.2).232 (5.9).024(.6).708 (18)1.534 (39)1.389(35.3).590 (15)1.070(27.2).991(25.2).142(3.6).059(1.5).031 (.8).779(19.8)1.180(30)Dimensions in inches (mm)PCB <strong>Power</strong> <strong>Filters</strong>Oscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeterInsertion Loss (dB)Insertion Loss (dB)908060-BHP-010-X-117060-BHP-020-X-1160504060-BHP-030-X-113060-BHP-060-X-11201000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)908070605040302060-BHP-XXX-X-1160-BHP-XXX-X-460-BHP-010-X-460-BHP-020-X-460-BHP-030-X-460-BHP-060-X-4Insertion Loss (dB)Insertion Loss (dB)90807060504030201060-BHP-010-3-1160-BHP-020-3-1160-BHP-030-3-1160-BHP-060-3-1100.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)908070605040302060-BHP-XXX-3-1160-BHP-XXX-3-460-BHP-010-3-460-BHP-020-3-460-BHP-030-3-460-BHP-060-3-41000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)1000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5857


PCB <strong>Power</strong> <strong>Filters</strong>Miniature Printed Circuit BoardPCB <strong>Power</strong> <strong>Filters</strong>11-MPC SeriesFeatures■ Miniature general purpose PCB mounted filter■ Requires minimal PCB real estate space■ Low cost■ Operating temperature: -25°C to +70°C■ Two forms of cases are available:metal case and plastic caseApplications■ Personal computers and peripherals■ Digital equipment■ Measuring instruments and medical equipment■ TV & VCR monitors and display units■ Home appliancesCircuit DiagramCircuit 1Circuit 2Circuit 3SpecificationsModelRated Voltage(@ 50/60Hz)RatedCurrentLeakage Current(Max.)CircuitDiagramFigureTemperature Rise(Max.)11-MPC-001-2-B5uA1B11-MPC-001-5-A1AA11-MPC-001-5-B11-MPC-002-5-B11-MPC-002-5-D11-MPC-003-5-E120/250VAC2A3A0.50mA23BDE30°C11-MPC-006-5-B11-MPC-006-5-C6A2BC11-MPC-016-5-B16A0.2mA4BNote: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 17.5g58SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


PCB <strong>Power</strong> <strong>Filters</strong>Miniature Printed Circuit Board11-MPC SeriesFigure AFigure BFigure C.03 (1) (5X)0.6 0.9(16) (25)0.9 2.0(25)±.007 (51).30 (7.5)1.9 (30).30 (7.5)0.6(16)0.9 (25) 0.6(15)0.4(10)0.9 (25)2.5 (64)1.4 (36)0.6 (15)±.031.1 (29)1.7 (44).79 (20).60(15)±.07Figure DFigure E0.03 (1) (5X)1.4 (36)1.8 (45)0.3 (8) 1.10.3 (8) (28)Common Mode0.6(16)0.6 (15)±.071.4 (35.5)1.9 (49).45(11.5) 1.4.45 (35)(11.5)1.1 (27) .15(4)Normal ModeDimensions in inches (mm)PCB <strong>Power</strong> <strong>Filters</strong>Oscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeterInsertion Loss (dB)8011-MPC-001;-0027011-MPC-001-5-B 11-MPC-001-5-A6011-MPC-001-2-B50403011-MPC-002-5-D2011-MPC-002-5-B1000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)807060504011-MPC-001;-00211-MPC-002-5-D11-MPC-001-5-B11-MPC-001-2-B302011-MPC-001-5-A1011-MPC-002-5-B00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)807060504030201011-MPC-003;-006;-01611-MPC-006-5-C11-MPC-003-5-E11-MPC-006-5-B11-MPC-016-5-BInsertion Loss (dB)8011-MPC-003;-006;-016706011-MPC-016-5-B5011-MPC-003-5-E4030201011-MPC-006-5-C11-MPC-006-5-B00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5859


<strong>Power</strong> Line <strong>Filters</strong><strong>Power</strong> Line <strong>Filters</strong>Appliance <strong>Filters</strong>62-AL/62-AC SeriesFeatures■ Low-cost plastic case■ Compact design requires minimal real estate space■ Suitable for products that must conformto FCC regulations■ Wide variety of circuit and filtering options■ Good filtering characteristics for both normal modeand common mode■ Epoxy molded for reliability■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 61)Applications■ Personal computers and peripherals■ Digital equipment■ Industrial equipment■ Vending machines■ Home appliances■ Office equipmentSpecificationsTested and found to beIAW VDE 0565 Part 3.371(9.4)1.527 (38.8)Circuit Diagrams62-A*LSeries62-A*CSeriesFast-on tab #110.629(16.0).177 x .138 (4.5 x 3.5).371(9.4).374 (9.5).263 (6.7)R1.220(31.0).657(16.7)LC XDimensions in inches (mm)R* R= w/ Bleeder ResistorF = w/o Bleeder ResistorL1.573 (40.0).994 (24.0)C XC Y1C Y2C Y1C Y2Model*62-AFL-010-3-1162-AFC-010-3-1162-AFL-010-5-1162-AFC-010-5-1162-AFL-016-3-1162-AFC-016-3-1162-AFL-016-5-1162-AFC-016-5-1162-AFL-030-3-1162-AFC-030-3-1162-AFL-030-5-1162-AFC-030-5-1162-AFL-045-3-1162-AFC-045-3-1162-AFL-045-5-1162-AFC-045-5-1162-AFL-060-3-1162-AFC-060-3-1162-AFL-060-5-1162-AFC-060-5-11Rated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y C X (L 1 ) Rise (Max.)250VAC1.0A1.6A0.35mA0.50mA0.35mA0.50mA2200pF3300pF11.0mH6.0mH0.35mA 2200pF3.0A 0.1uF2.4mH40°C0.50mA 3300pF4.5A6.0A0.35mA0.50mA0.35mA0.50mA2200pF3300pF2200pF3300pF2200pF3300pF1.0mH0.53mHNote: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max.* Available with bleeder resistorReplace F with R for part number60 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


Temperature Characteristics120<strong>Power</strong> Line <strong>Filters</strong>Appliance <strong>Filters</strong>Current (%)1008060402062-AL/62-AC SeriesCommon Mode0Normal Mode20 30 40 50 60 70 80 90Ambient Temperature (°C)Normal ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeterInsertion Loss (dB)Insertion Loss (dB)62-AFL-xxx-3-118062-AFL-030-3-117062-AFL-016-3-116062-AFL-010-3-11504030201000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)62-AFC-XXX-3-118062-AFC-030-3-117062-AFC-016-3-116062-AFC-010-3-11504030201062-AFL-060-3-1162-AFL-045-3-1162-AFC-060-3-1162-AFC-045-3-11Insertion Loss (dB)Insertion Loss (dB)8062-AFL-045-3-11706062-AFL-016-3-115062-AFL-010-3-11403062-AFL-030-3-112062-AFL-060-3-111000.1 0.2 0.5 1 2 5 10 20 50807060504030201062-AFL-XXX-3-1162-AFC-XXX-3-1162-AFC-030-3-1162-AFC-016-3-1162-AFC-010-3-11Frequency (MHz)62-AFC-045-3-1162-AFC-060-3-11<strong>Power</strong> Line <strong>Filters</strong>00.1 0.2 0.5 1 2 5 10 20 5000.1 0.2 0.5 1 2 5 10 20 50Insertion Loss (dB)62-AFL-xxx-5-118062-AFL-030-5-117062-AFL-016-5-1160 62-AFL-010-5-115040302010Frequency (MHz)62-AFL-045-5-1162-AFL-060-5-11Insertion Loss (dB)807060504030201062-AFL-xxx-5-11Frequency (MHz)62-AFL-016-5-1162-AFL-030-5-1162-AFL-010-5-1162-AFL-060-5-1162-AFL-045-5-11Insertion Loss (dB)00.1 0.2 0.5 1 2 5 10 20 508062-AFC-xxx-5-11Frequency (MHz)7060 62-AFC-010-5-1150403062-AFC-060-5-11201062-AFC-045-5-1162-AFC-030-5-1162-AFC-016-5-1100.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)62-AFC-xxx-5-11807062-AFC-016-5-1162-AFC-030-5-116062-AFC-010-5-115040302062-AFC-045-5-111062-AFC-060-5-1100.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5861


<strong>Power</strong> Line <strong>Filters</strong><strong>Power</strong> Line <strong>Filters</strong>Single Stage62-PPF/PQF/PRF SeriesFeatures■ Low-cost plastic case■ Compact design requires minimal real estate space■ Suitable for products that must conformto FCC and FTZ regulations■ Wide variety of circuit and filtering options■ Good filtering characteristics for both normal modeand common mode■ Epoxy molded for reliability■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 63)Applications■ Personal computers and peripherals■ Digital equipment■ Industrial equipment■ Vending machines■ Office equipmentSpecificationsTested and found to beIAW VDE 0565 Part 3Circuit Diagrams62-PQF*Series62-PPF*Series62-PRF*SeriesRL 1C X C YRC YL 1C YC XL 1L 1* Bleeder Resistor is available only for62-P(Q/R/P)F-XXX-X-12RC XC YC YC YModel62-PQF-020-5-1162-PQF-020-5-1262-PPF-020-5-1162-PPF-020-5-1262-PQF-030-5-1162-PQF-030-5-1262-PPF-030-5-1162-PPF-030-5-1262-PQF-060-5-1162-PQF-060-5-1262-PPF-060-5-1162-PPF-060-5-1262-PRF-010-5-1162-PRF-010-5-1262-PRF-020-5-1162-PRF-020-5-1262-PRF-030-5-1162-PRF-030-5-12Rated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y C X (L 1 ) Rise (Max.)250VAC2A3A6A1A2A3A0.50mA3300pF0.1uF.22uF0.1uF.22uF0.1uF.22uF0.1uF.22uF0.1uF.22uF0.1uF.22uF0.1uF.22uF0.1uF.22uF0.1uF.22uF15mH8mH2.1mH486uH181uH97uH30°CNote: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. (except 62-PRF-010-5-11) at rated current62-PRF-010-5-11: 1.5V max. at rated currentWeight: 62-PPF & PQF Series: 2.11 ounces (60 grams)62-PRF Series: 1.76 ounces (50 grams)62 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Line <strong>Filters</strong>Single Stage Wire Leads62-PML SeriesFeaturesTested and found to beIAW VDE 0565 Part 3■ Compact design requires minimal real estate space■ Suitable for products that must conformto FCC and FTZ regulations■ Excellent attenuation for high voltage impulse■ Metal case provides effective shieldingCircuit Diagram<strong>Power</strong> Line <strong>Filters</strong>■ Excellent filtering characteristics for both normal modeand common mode■ Structure provides effective shielding for noisegenerated externally and internally■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 65)Applications■ Digital equipment■ Personal computers and peripherals■ Measuring instruments■ Medical equipment■ Factory automation equipment12RC XL 1C XC YC Y3E4SpecificationsModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y C X (L 1 ) Rise (Max.)62-PML-015-3-1162-PML-015-5-111.5A0.35mA0.50mA2200pF3300pF10.0mH62-PML-030-3-1162-PML-030-5-1162-PML-050-3-1162-PML-050-5-1162-PML-100-5-11250VAC3A5A10A0.35mA0.50mA0.35mA0.50mA0.50mA2200pF3300pF2200pF3300pF3300pF0.1uF4.3mH2.4mH2.2mH30°CNote: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentWeight: 62-PML-015 Series: 3.06 ounces (87 grams)62-PML-030 Series: 3.17 ounces (90 grams)62-PML-050 Series: 3.28 ounces (93 grams)Discharge time: 0.4 sec. max.64 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Line <strong>Filters</strong>Single Stage Wire Leads62-PML SeriesTemperature Characteristics120BKBKWHG/YWH1.573(40)1.219(31).786(20) 1.966(50)100PVCInsulated wireAWG # 20 UL10152 — .138 x .181 (3.5 x 4.6).629(16).944 (24)80Current (%)6040.395(10)5.112* (130)1.856 (47.2)5.112* (130).395 (10)20* Custom lengths available upon request.Dimensions in inches (mm)020 30 40 50 60 70 80 90Ambient Temperature (°C)Common ModeNormal Mode<strong>Power</strong> Line <strong>Filters</strong>Oscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeterInsertion Loss (dB)8070 62-PML62-PML-015-5-216062-PML-030-5-2150403062-PML-050-5-21201000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)9062-PML80706062-PML-050-5-1150403062-PML-030-5-1162-PML-015-5-11201000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5865


<strong>Power</strong> Line <strong>Filters</strong>Single Stage Wire Leadsfor Medical Purpose Applications12-PML & 12-PMF SeriesFeatures■ Compact design requires minimal real estatespace■ Suitable for products that must conformto FCC and FTZ regulations■ Excellent attenuation for high voltage impulseCircuit Diagram■ Metal case provides effective shielding■ Excellent filtering characteristics for both normalmode and common mode■ Structure provides effective shielding for noisegenerated externally and internally■ Operating temperature: -25°C to +70°CCircuit 1■ Low leakage current<strong>Power</strong> Line <strong>Filters</strong>Applications■ Digital equipment■ Personal computers and peripherals■ Measuring instruments■ Medical equipment■ Factory automation equipmentSpecificationsCircuit 2ModelRated Voltage(@ 50/60Hz)RatedCurrentLeakage Current(Max.)CircuitDiagramFigureTemperature Rise(Max.)12-PML-001-2-A1A12-PML-002-2-A12-PML-006-2-A2A6A1A12-PML-010-2-A12-PMF-001-2-B120/250VAC10A1A5uA30°C12-PMF-002-2-B2A2B12-PMF-006-2-B6A12-PML-001-2-C1A1CNote: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentDischarge time: 0.4 sec. max.66 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Line <strong>Filters</strong>Single Stage Wire Leadsfor Medical Purpose Applications12-PML & 12-PMF SeriesFigure A.31 (8).13 (3.5) X .17 (4.5) SLOT (2 PLACES)Figure C.13 (3.5) X .17 (4.5) SLOT (2 PLACES).94(24)1.5(39)1.9(49)1.2(30)1.25 (32)1.6 (42)1.9 (48).78 (20)1.7 (44).78 (20)Figure B.14 (3.8) (2X)1.2(30)Insertion Loss (dB)Common Mode8070301.7 (44)2.2 (56)2.4 (61)Oscillator50Ω1 3Filter2 450Ω12-PML-001;-002;-006;-0106012-PML-001-2-A50402012-PML-002-2-A1012-PML-010-2-A.79 (20)12-PML-006-2-A50ΩLevelMeterInsertion Loss (dB)Normal ModeOscillator50Ω50Ω1 3Filter2 450Ω12-PML-001;-002;-006;-0108012-PML-002-2-A7012-PML-001-2-A60504030201012-PML-010-2-A12-PML-006-2-ADimensions in inches (mm)50ΩLevelMeter<strong>Power</strong> Line <strong>Filters</strong>00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)807012-PMF-001;-002;-006;-010807012-PMF-001;-002;-006;-01012-PMF-001-2-B12-PMF-002-2-BInsertion Loss (dB)60504030201012-PMF-001-2-B 12-PMF-002-2-B12-PMF-006-2-B11-PML-001-2-CInsertion Loss (dB)60504030201011-PML-001-2-C12-PMF-006-2-B00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5867


<strong>Power</strong> Line <strong>Filters</strong>Single Stage62-LMF & LMB SeriesFeatures■ Space saving, compact designsTested and found to beIAW VDE 0565 Part 3<strong>Power</strong> Line <strong>Filters</strong>■ Suitable for products that must conformto FCC and FTZ regulations■ Excellent filtering characteristics for both normal modeand common mode■ Structure provides effective shielding for noisegenerated externally and internally■ Metal case provides effective shielding■ Rugged construction■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 69)Applications■ Digital equipment■ Office automation equipment, such as copyand fax machines■ Computers and peripherals■ Instrumentation and controlsSpecificationsCircuit Diagram1R2C XL 1C XC YC Y3E4Model*Rated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y C X (L 1 ) Rise (Max.)62-LMB-030-5-1162-LMF-030-5-113A0.1uF14mH62-LMB-050-5-1162-LMF-050-5-1162-LMB-080-5-1162-LMF-080-5-11250VAC5A8A0.50mA3300pF0.1uF & .22uF.22uF7.0mH4.2mH45°C62-LMB-100-5-1162-LMF-100-5-1110A.33uF2.2mHNote: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max. at rated currentDischarge time: 0.4 sec. max.Weight: 5.3 ounces (150 grams)*62-LMF - designates Fast-on terminals62-LMB - designates Bolt-in terminals62-LML - wire lead in/outputs also available68 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


Temperature Characteristics120<strong>Power</strong> Line <strong>Filters</strong>Single StageCurrent (%)10080604062-LMF & LMB Series20020 30 40 50 60 70 80 90Ambient Temperature (°C)62-LMB62-LMF.708(18.0).255(6.5)1.10(28.0).66(16.8)1.97(50.0).66(16.8).708(18.0).255(6.5)1.10(28.0).61(15.5)1.97(50.0)2 - ø4.8.61(15.5)5-M41.22(31.0)1.97(50.0)2.39(60.7± 0.5)2.79(70.9)1.22(31.0)1.97(50.0)2.39(60.7± 0.5)2.79(70.9).61(15.5)2 - ø .188(4.8).61(15.5)Fast-on Tabs #250.031 (0.8) tDimensions in inches (mm)<strong>Power</strong> Line <strong>Filters</strong>Common ModeNormal ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeterInsertion Loss (dB)90807060504030201062-LMF & LMB62-LM-030-5-1162-LM-050-5-1162-LM-100-5-1162-LM-080-5-1100.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)90807060504030201062-LMF & LMB62-LM-030-5-1162-LM-050-5-1162-LM-100-5-1162-LM-080-5-1100.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5869


<strong>Power</strong> Line <strong>Filters</strong>Single Stage<strong>Power</strong> Line <strong>Filters</strong>62-PMF & PMB SeriesFeaturesTested and found to beIAW VDE 0565 Part 3■ Space-saving, compact designs■ Suitable for products that must conformto FCC regulations■ Excellent attenuation for high voltage impulse■ Metal case provides effective <strong>EMI</strong> shielding■ Excellent filtering characteristics for both normal modeand common mode■ Epoxy molded for internal component reliability■ Structure provides effective shielding for noisegenerated externally and internally■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 71)Applications■ Digital equipment■ Computers and peripherals■ Measuring instruments■ Medical equipment■ Equipment requiring very high impulse attenuation■ Factory automation equipment■ Industrial equipment such as UPS, invertersand converters■ Telecommunications equipment■ Office automation equipment, such as copyand fax machinesCircuit Diagram1R2C XL 1C XC YC Y3E4SpecificationsModel*Rated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y C X (L 1 ) Rise (Max.)62-PMB-050-5-1162-PMF-050-5-115A0.1uF14mH62-PMB-080-5-1162-PMF-080-5-118A.1uF & .22uF7.0mH30°C62-PMB-100-5-1262-PMF-100-5-12250VAC10A0.50mA3300pF.22uF4.2mH62-PMB-150-5-1362-PMF-150-5-1362-PMB-200-5-1362-PMF-200-5-1315A20A.33uF2.2mH1.8mH35°C45°C**Note: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max.Discharge time: 0.4 sec. max.Weight: 8.82 ounces ( 250 grams)* PMF - designates Fast-on terminalsPMB - designates Bolt-in terminals** The temperature rise of 20 amp units can be decreased to 30°Cby mounting on 200 X 200 x 1.0(mm) steel chassis70 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Line <strong>Filters</strong>Single Stage62-PMF & PMB Series62-PMFTemperature Characteristics1203.291 (83.7)2.937 (74.7) Fast-on tab#2502 — .197 (5)BC1.258(32)1.998(50.8)100.610(15.5)2.497 (63.5).610(15.5)A.315(8)Current (%)80604062-PMB3.291 (83.7)2.937 (74.7) 5 — .157(M4)2 — .197(5)BC1.258(32) 1.998(50.8)20.649.649(16.5) 2.497 (63.5) (16.5)A.315(8)020 30 40 50 60 70 80 90Ambient Temperature (°C)Common ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterMODEL A B C62-PMF/PMB-100-20062-PMF/PMB-050-080Normal ModeOscillator50Ω1.490 .944 .433(38) (24) (11)1.258 .786 0(32) (20) (0)50Ω1 3Filter2 450ΩDimensions in inches (mm)50ΩLevelMeter<strong>Power</strong> Line <strong>Filters</strong>62-PMB-050-6Oscillator50ΩR1 R2S1 Filter S2T1 T250Ω50Ω50ΩLevelMeter62-PMB-050-6Oscillator50Ω50Ω50ΩR1 R2S1 Filter S2T1 T250Ω50Ω50ΩLevelMeterInsertion Loss (dB)90807060504030201062-PMB-050-5-1162-PMB-080-5-1162-PMB-100-5-1262-PMB-150-5-1362-PMB-200-5-1300.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)9062-PMB-200-5-138062-PMF-050-5-117060504062-PMF-150-5-13302062-PMF-080-5-111062-PMF-100-5-1200.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5871


<strong>Power</strong> Line <strong>Filters</strong>Single Stage12-PMF SeriesFeatures■ Space-saving, compact designs■ Suitable for products that must conformto FCC regulations■ Excellent attenuation for high voltage impulse■ Metal case provides effective <strong>EMI</strong> shielding■ Excellent filtering characteristics for both normal modeand common mode■ Epoxy molded for internal component reliability■ Structure provides effective shielding for noisegenerated externally and internally■ Operating temperature: -40°C to +85°CCircuit DiagramCircuit 1Circuit 2<strong>Power</strong> Line <strong>Filters</strong>Applications■ Digital equipment■ Computers and peripherals■ Measuring instruments■ Medical equipment■ Equipment requiring very high impulse attenuation■ Factory automation equipment■ Industrial equipment such as UPS, invertersand converters■ Telecommunications equipment■ Office automation equipment, such as copyand fax machinesCircuit 3Circuit 5Circuit 4Circuit 6SpecificationsModelRated Voltage(@ 50/60Hz)RatedCurrentLeakage Current(Max.)CircuitDiagramFigureTemperature Rise(Max.)12-PMF-001-5-A1A1A12-PMF-002-5-B2A2B12-PMF-003-5-A12-PMF-003-5-B3A42AB12-PMF-006-5-A4A12-PMF-006-5-C6A1C12-PMF-006-5-D6D12-PMF-010-5-A12-PMF-010-5-C12-PMF-015-5-C12-PMF-015-5-E120/250VAC10A15A0.5mA23ACE30°C12-PMF-020-5-C12-PMF-020-5-D12-PMF-020-5-E20A5CDENote: Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max.Discharge time: 0.4 sec. max.72 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Line <strong>Filters</strong>Single Stage12-PMF SeriesFigure A.14 (3.8)Figure B2 .34 (8.8)2.4(62)1.8(46)2.1(54)1.7 (44)2.2 (56).78 (20)1.2(30)3.2 (81)1.25 (32).86 (22)2.4 (62)Figure CFigure DFigure E2.17 (8.8)2 - .18 (4.8).41 (10.5)1.7 (4.5) (2X)2.0(52)2.0 (52)2.4 (63)1.4 (37)1.9 2.3 2.8(50) (60) (10.5)2.9(74)2.5 3.3(64) (85)3.2 (82)Dimensions in inches (mm)1.7 (44)2.9 (74)1.1 (28)2.0 (51)3.1 (80)1.4 (36)Common ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterNormal ModeOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeter<strong>Power</strong> Line <strong>Filters</strong>Insertion Loss (dB)Insertion Loss (dB)8012-PMF-001;-002;-003;-0067012-PMF-001-5-A6012-PMF-002-5-B5012-PMF-003-5-B12-PMF-006-5-A4012-PMF-003-5-A 12-PMF-006-5-C302012-PMF-006-5-D1000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)8012-PMF-001;-002;-003;-0067012-PMF-001-5-A6012-PMF-002-5-B5012-PMF-003-5-B12-PMF-006-5-A4012-PMF-003-5-A 12-PMF-006-5-C302012-PMF-006-5-D1000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)Insertion Loss (dB)12-PMF-001;-002;-003;-0068012-PMF-001-5-A12-PMF-006-5-C7012-PMF-006-5-A6012-PMF-006-5-D50403012-PMF-003-5-B2012-PMF-003-5-A1012-PMF-002-5-B00.1 0.2 0.5 1 2 5 10 20 508030Frequency (MHz)12-PMF-010;-015;-0207012-PMF-010-5-C6012-PMF-020-5-C50402012-PMF-020-5-D12-PMF-020-5-E1012-PMF-015-5-C00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)12-PMF-015-5-E12-PMF-010-5-ASPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5873


<strong>Power</strong> Line <strong>Filters</strong><strong>Power</strong> Line <strong>Filters</strong>Single Stage - Higher Current62-PMB SeriesFeatures■ Space-saving, compact designs■ Suitable for products that must conformto FCC regulations■ Excellent attenuation for high voltage impulse■ Metal case provides effective shielding■ Excellent filtering characteristics for both normal modeand common mode■ Epoxy molded for internal component reliability■ Structure provides effective shielding for noisegenerated externally and internally■ Safety agency approvals pending■ Designed to be in accordance with VDE 0565 Part 3■ Operating temperature: -25°C to +85°C(including temperature rise)Applications■ Digital equipment■ Computers and peripherals■ Measuring instruments■ Medical equipment■ Equipment requiring very high impulse attenuation■ Factory automation equipment■ Industrial equipment such as UPS, invertersand converters■ Telecommunications equipment■ Office automation equipment, such as copyand fax machinesCircuit Diagram13L 1C YC X R C XELC Y124SpecificationsModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y C X (L 1 ) Rise (Max.)62-PMB-300-5-1462-PMB-400-5-14250VAC30A40A0.50mA3300pF.47uF1.6mH0.8mH45°CNote: Test voltage: 1500VAC one minute, line to earthInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max.Discharge time: 0.4 sec. max.Weight: 8.82 ounces (250 grams)74 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Line <strong>Filters</strong>Single Stage - Higher Current62-PMB Series62-PMB-300-5-14 and 62-PMB-400-5-143.15 (80)3.74 (95±.08)4.13 (105)3.03 (77±0.5)3.70 (94)3.85 (98)5.591 (142.00)1.022(26.0)2.049 (52.0)0.511(13.0)Dimensions in inches (mm)<strong>Power</strong> Line <strong>Filters</strong>Normal ModeCommon ModeOSCILLATOR50 ohm13FILTER2450 ohm 50 ohm50 ohmLEVELMETEROSCILLATOR50 ohm12FILTER3450 ohm50 ohmLEVELMETERInsertion Loss (dB)908070605062-PMB-400-5-1440302062-PMB-300-5-141000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)908070605062-PMB-300-5-1440302062-PMB-400-5-141000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5875


<strong>Power</strong> Line <strong>Filters</strong><strong>Power</strong> Line <strong>Filters</strong>Single Stage - Higher Current12-PMB SeriesFeatures■ Space-saving, compact designs■ Suitable for products that must conformto FCC regulations■ Excellent attenuation for high voltage impulse■ Metal case provides effective shielding■ Excellent filtering characteristics for both normal modeand common mode■ Epoxy molded for internal component reliability■ Structure provides effective shielding for noisegenerated externally and internally■ Designed to be in accordance with VDE 0565 Part 3■ Operating temperature: -40°C to +85°CApplications■ Digital equipment■ Computers and peripherals■ Measuring instruments■ Medical equipment■ Equipment requiring very high impulse attenuation■ Factory automation equipment■ Industrial equipment such as UPS, invertersand converters■ Telecommunications equipment■ Office automation equipment, such as copyand fax machinesCircuit Diagram13L 1C YC X R C XELC Y124SpecificationsModelRated Voltage(@ 50/60Hz)RatedCurrentLeakage Current(Max.)CircuitDiagramFigureTemperature Rise(Max.)12-PMB-025-5-A12-PMB-030-5-A12-PMB-035-5-B12-PMB-050-5-B120/250VAC25A30A35A50A0.5mA1AB30°C12-PMB-100-8-C12-PMB-120-8-C100A120A1.0mACNote: Test voltage: 1500VAC one minute, line to earthInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max.Discharge time: 0.4 sec. max.Weight: 8.82 ounces (250 grams)76 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Line <strong>Filters</strong>Single Stage - Higher Current12-PMB SeriesFigure A Figure B Figure C1M4 STUD(4X).17 (4.5) ±.007(2X)M4 THREAD (10X)0.2 (6.3)0.5 (4.5)M8 THREAD (4X)0.16 (4.2) X 0.25 (6.4) (2X)2.0(52)2.0(24) ±.033.3 3.7 4.1(84) (95)(105)4.3 4.5 5.1(110) (115) (130)0.2 (6) ±.030.8 (22)±.031.4 (37) MAX2.5 (64) MAX2.9 (75) ±.013.9 (101) MAX1.5 (38.5)2.0 (51)3.9 (98.5)5.3 (135)1.9 (50) 3.1 (80)4.7 (120)7.0 (180)Dimensions in inches (mm)Common ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterNormal ModeOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeter<strong>Power</strong> Line <strong>Filters</strong>807012-PMB-025;-030;-03512-PMB-025;-030;-0358012-PMB-035-5-B70Insertion Loss (dB)60504030201012-PMB-025-5-A12-PMB-030-5-A12-PMB-035-5-BInsertion Loss (dB)60504030201012-PMB-025-5-A12-PMB-030-5-A00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)8012-PMB-050;-100;-1207012-PMB-100-8-C60504030201012-PMB-050-5-B12-PMB-120-8-CInsertion Loss (dB)8012-PMB-050;-100;-12070605012-PMB-120-8-C4012-PMB-100-8-C30201012-PMB-050-5-B00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5877


<strong>Power</strong> Line <strong>Filters</strong><strong>Power</strong> Line <strong>Filters</strong>DC - Higher Current12-PMF & 12 PMB DC SeriesFeatures■ Space-saving, compact designs■ Suitable for products that must conform to FCC regulations■ Excellent attenuation for high voltage impulse■ Metal case provides effective shielding■ Excellent filtering characteristics for both normal modeand common mode■ Epoxy molded for internal component reliability■ Structure provides effective shielding for noisegenerated externally and internally■ Designed to be in accordance with VDE 0565 Part 3■ Operating temperature: -40°C to +85°CApplications■ Digital equipment■ Computers and peripherals■ Measuring instruments■ Equipment requiring very high impulse attenuation■ Factory automation equipment■ Industrial equipment such as UPS, inverters and converters■ Telecommunications equipmentSpecificationsModel12-PMF-006-DC-C12-PMF-010-DC-C12-PMF-015-DC-C12-PMF-020-DC-C12-PMF-025-DC-D12-PMB-025-DC-F12-PMB-030-DC-F12-PMB-035-DC-F12-PMB-040-DC-F12-PMB-040-DC-B12-PMB-050-DC-B12-PMB-060-DC-B12-PMB-080-DC-G12-PMB-080-DC-C12-PMB-100-DC-C12-PMB-120-DC-C12-PMB-140-DC-C12-PMB-180-DC-E12-PMB-200-DC-E12-PMB-260-DC-ERated Voltage(@ 50/60Hz)48/250VDCRatedCurrent6A10A15A20A25A30A35A40A50A60A80A100A120A140A180A200A260ANote: Test voltage: 1500VAC one minute, line to earthInsulation resistance: 300 Mohm min. at 500VDCVoltage drop: 1V max.CircuitDiagram1232Circuit DiagramCircuit 1Circuit 2Circuit 3Discharge time: 0.4 sec. max.Weight: 8.82 ounces (250 grams)FigureABCDEFGTemperature Rise(Max.)30°C78 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


Figure A<strong>Power</strong> Line <strong>Filters</strong>DC - Higher Current12-PMF & 12-PMB DC SeriesFigure BFigure CFigure DFigure E Figure F Figure G1.9 (50)±.003Insertion Loss (dB)Common Mode8070605040302010Oscillator50Ω1 3Filter2 450Ω50ΩLevelMeter12-PMF-006;-010;-015;-020;-02512-PMF-006-DC-C12-PMF-010-DC-C12-PMF-015-DC-C12-PMF-020-DC-CDimensions in inches (mm)12-PMF-025-DC-DInsertion Loss (dB)Normal Mode8070605040302010Oscillator50Ω50Ω1 3Filter2 450Ω12-PMF-006;-010;-015;-020;-02512-PMF-020-DC-C12-PMF-015-DC-C12-PMF-006-DC-C12-PMF-010-DC-C50ΩLevelMeter12-PMF-025-DC-D<strong>Power</strong> Line <strong>Filters</strong>00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)80706012-PMB-025; thru -26012-PMB-025-DC-F12-PMB-030-DC-F12-PMB-035-DC-F12-PMB-040-DC-F504012-PMB-180-DC-E3012-PMB-200-DC-E12-PMB-260-DC-E2012-PMB-100-DC-C12-PMB-040-DC-B1012-PMB-120-DC-C12-PMB-050-DC-B12-PMB-140-DC-C12-PMB-060-DC-B00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)12-PMB-080-DC-G12-PMB-080-DC-CInsertion Loss (dB)80706050403012-PMB-025; thru -26012-PMB-025-DC-F12-PMB-030-DC-F12-PMB-035-DC-F12-PMB-040-DC-F12-PMB-040-DC-B2012-PMB-050-DC-B12-PMB-100-DC-C12-PMB-180-DC-E 12-PMB-060-DC-B12-PMB-120-DC-C10 12-PMB-200-DC-E12-PMB-140-DC-C12-PMB-260-DC-E00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)12-PMB-080-DC-G12-PMB-080-DC-CSPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5879


<strong>Power</strong> Line <strong>Filters</strong><strong>Power</strong> Line <strong>Filters</strong>Dual Stage62-MMF SeriesFeatures■ Suitable for products that must conformto FCC regulations■ Excellent attenuation for high voltage impulse■ Metal case provides effective <strong>EMI</strong> shielding■ Two stages for excellent filtering characteristics■ Epoxy molded for reliability■ Structure provides effective shielding for noisegenerated both externally and internally■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 81)Applications■ Digital equipment■ Personal computers and peripherals■ Measuring instruments and medical equipment■ Telecommunications equipment■ Equipment requiring very high noise attenuationCircuit Diagram62-MMF-XXX-7-111 32L 1C X C XC XRC YC YL 1C YC YE4SpecificationsModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y1 C Y2 C X (L 1 ) (2X) Rise (Max.)62-MMF-030-7-11 250VAC 3A .7mA 3300pF 1000pF 0.1uF 3.7mH 30°C62-MMF-050-7-11 250VAC 5A .7mA 3300pF 1000pF 0.1uF 2.9mH 30°CNote: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCLeakage current: 0.7 mA max.Voltage drop: 1V max.Discharge time: 0.4 sec. max.Weight: 6.0 ounces (170 grams)80 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Line <strong>Filters</strong>Dual Stage62-MMF SeriesTemperature Characteristics1201003.291 (83.7)2.937 (74.7) Fast-on tab#250.786 (20).315(8)Current (%)806040.610(15.5)2.497 (63.5).610(15.5)2 – .197 (5)1.258 (32).315(8)1.258(32)1.998(50.8)20Dimensions in inches (mm)020 30 40 50 60 70 80 90Ambient Temperature (°C)Common ModeNormal Mode<strong>Power</strong> Line <strong>Filters</strong>Oscillator50Ω1 3Filter2 450Ω50ΩLevelMeterOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeterInsertion Loss (dB)62-MMF9080706062-MMF-050-7-115062-MMF-030-7-114030201000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)62-MMF9080706062-MMF-050-7-115062-MMF-030-7-114030201000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5881


<strong>Power</strong> Line <strong>Filters</strong><strong>Power</strong> Line <strong>Filters</strong>Dual Stage12-MMF & 12-MMB SeriesFeatures■ Suitable for products that must conformto FCC regulations■ Excellent attenuation for high voltage impulse■ Metal case provides effective <strong>EMI</strong> shielding■ Two stages for excellent filtering characteristics■ Structure provides effective shielding for noisegenerated both externally and internally■ Operating temperature: -40°C to +85°C■ High performance■ Low leakage currentApplications■ Digital equipment■ Switching power supplies■ Personal computers and peripherals■ Measuring instruments and medical equipment■ Telecommunications equipment■ Equipment requiring very high noise attenuationCircuit DiagramCircuit 1Circuit 2Circuit 3SpecificationsModelRated Voltage(@ 50/60Hz)RatedCurrentLeakageCurrent (Max.)CircuitDiagramFigureTemperature Rise(Max.)12-MMF-002-5-F12-MMF-003-5-F12-MMF-003-5-A12-MMF-006-5-F12-MMF-006-5-G12-MMF-008-5-B12-MMF-010-5-F12-MMF-010-5-G12-MMF-010-5-B12-MMF-012-5-B12-MMB-015-5-E12-MMB-020-5-F12-MMB-030-5-D12-MMB-050-5-C120/250VAC2A3A6A8A10A12A15A20A30A50A0.5mA132ABCBDBDEDFG30°CNote: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCLeakage current: 0.7 mA max.Voltage drop: 1V max.Discharge time: 0.4 sec. max.82 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Line <strong>Filters</strong>Dual StageFigure C1.81 2.44(46) (62)Ø .15 (3.8) (2X)2.12(54)12-MMF & 12-MMB Series.87 (22)1.26 (32)2.44 (62)Figure AFigure BFigure DØ .25 (6.4) (2X)2.00(51)2.24(57)Figure EM4 STUD (7X)2.00 ± .02 (75 ± .5)3.35 (85) MAX.21 (5.4) X .37 (9.4) HOLE (4X)Figure FM4 THREAD (5X).117 (4.5) X .25 (6.3) SLOT (4X)1.77 (45)Figure GM4 THREADM6 THREAD (4X)2.90 (73)2.42 (87)4.01 (102)3.38 1.65(86) (42)2.40 ± .007(60 ± .2)3.30(84)3.74 4.13(95) (105)3.93 4.52 5.12(100) (115) (130)2.30 (58)Dimensions in inches (mm).71 (18)6.30 (160)1.50 (38) 7.24 (184)7.95 (202)Common ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeter1.51 (38.5)2.01 (51)3.88 (98.5)5.31 (135)Normal ModeOscillator50Ω1.97 (50)50Ω1 3Filter2 450Ω3.15 (80)4.72 (120)7.09 (180)50ΩLevelMeter<strong>Power</strong> Line <strong>Filters</strong>807012-MMF-002;-003;-006;-00812-MMF-002;-003;-006;-0088012-MMF-006-5-G70Insertion Loss (dB)6050403012-MMF-002-5-F12-MMF-003-5-F12-MMF-006-5-F12-MMF-006-5-G2012-MMF-008-5-B1012-MMF-003-5-A00.01 0.05 0.15 0.45 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)6050403012-MMF-003-5-F2012-MMF-003-5-A1000.01 0.05 0.15 0.45 1 2 5 10 20 50Frequency (MHz)12-MMF-002-5-F 12-MMF-006-5-F12-MMF-008-5-B807012-MMF-010;-012;-015;-020;-030;-050807012-MMF-010;-012;015;-020;-030;-05012-MMB-050-5-CInsertion Loss (dB)6012-MMB-030-5-D504030201012-MMB-050-5-C12-MMB-015-5-E12-MMF-010-5-F12-MMF-010-5-G 12-MMB-020-5-F12-MMF-010-5-B12-MMF-012-5-B00.01 0.05 0.15 0.45 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)6012-MMF-010-5-F5040302012-MMF-010-5-G12-MMF-010-5-B12-MMF-012-5-B12-MMB-030-5-D12-MMB-015-5-E12-MMB-020-5-F1000.01 0.05 0.15 0.45 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5883


<strong>Power</strong> Line <strong>Filters</strong><strong>Power</strong> Line <strong>Filters</strong>Dual Stage12-MMF & 12-MMB SeriesFeatures■ Suitable for products that must conformto FCC regulations■ Excellent attenuation for high voltage impulse■ Metal case provides effective <strong>EMI</strong> shielding■ Two stages for excellent filtering characteristics■ Structure provides effective shielding for noisegenerated both externally and internally■ Operating temperature: -40°C to +85°C■ High performanceApplications■ Digital equipment■ Personal computers and peripherals■ Measuring instruments and medical equipment■ Telecommunications equipment■ Equipment requiring very high noise attenuationCircuit DiagramCircuit 1Circuit 2SpecificationsModel12-MMF-003-11-F12-MMF-006-11-F12-MMF-010-11-F12-MMB-012-11-A12-MMB-015-11-G12-MMB-020-11-D12-MMB-030-11-D12-MMB-040-11-B12-MMB-040-11-E12-MMB-050-11-HRated Voltage(@ 50/60Hz)120/250VACRatedCurrent3A6A10A12A15A20A30ANote: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCLeakage current: 0.7 mA max.Voltage drop: 1V max.Discharge time: 0.4 sec. max.Weight: 6.0 ounces (170 grams)40A50ALeakageCurrent (Max.)1.5mACircuitDiagram12121FigureABCBDEFTemperature Rise(Max.)30°C84 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Line <strong>Filters</strong>Dual Stage12-MMF & 12-MMB SeriesFigure AFigure BFigure CØ .18 ± .007 (2X)(4.5 ± 0.2)M4 THREAD (4X)1.73 3.33± .04 MAX(44 ± 1) (84.5)3.74± .02(95 ± 0.5)4.13MAX(105)2.24(57).75 ± .04 (19 ± 1)1.53 MAX (39)2.01 ± .02(51 ± 0.5)3.90 MAX (99)6.20 MAX (157)2.90 (73)1.80 (45) 3.42 (87)4.30 (109)Figure DFigure EFigure F.165 (4.2) X .25 (6.4) (4X)M6 THREAD (5X).25 (6.4) x .37(9.4) SLOT (4X).177 (4.5) X .25 (6.5) SLOT (2X)M8 THREAD (4X)2.28(58)3.54 5.90(90) (150)2.24(57).95(24.1)3.93 4.53 5.12(100) (115) (130)3.54(90)1.77 (45)8.66 (220)9.57 (243)10.27 (261)Common ModeOscillator50Ω1 3Filter2 450Ω1.77(45).35 (9).90 (23)Dimensions in inches (mm)50ΩLevelMeter2.91 (74)3.66 (93)4.01 (102)Normal ModeOscillator50Ω1.97(50) 3.14 (80)4.72 (120)7.08 (180)50Ω1 3Filter2 450Ω50ΩLevelMeter<strong>Power</strong> Line <strong>Filters</strong>Insertion Loss (dB)Insertion Loss (dB)12-MMF-003;-006;-010;-012;-01512012-MMF-003-11-F10512-MMF-012-11-A90756012-MMF-006-11-F4512-MMF-010-11-F3012-MMF-015-11-G1512000.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)10512-MMF-020;-030;-040;-05012-MMF-040-11-B 12-MMF-020-11-D907560453012-MMF-040-11-E15012-MMF-030-11-D12-MMF-050-11-H0.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)Insertion Loss (dB)1201059012-MMF-003;-006;-010;-012;-01512-MMF-012-11-A12-MMF-003-11-F75604512-MMF-015-11-G3012-MMF-006-11-F1512-MMF-010-11-F00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)12012-MMF-020;-030;-040;-05010512-MMF-040-11-B9075604512-MMF-050-11-H3012-MMF-040-11-E12-MMF-030-11-D1512-MMF-020-11-D00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5885


<strong>Power</strong> Line <strong>Filters</strong><strong>Power</strong> Line <strong>Filters</strong>Dual Stage12-MMF & 12-MMB SeriesFeatures■ Suitable for products that must conformto FCC regulations■ Excellent attenuation for high voltage impulse■ Metal case provides effective <strong>EMI</strong> shielding■ Two stages for excellent filtering characteristics■ Epoxy molded for reliability■ Structure provides effective shielding for noisegenerated both externally and internally■ Operating temperature: -25°C to +85°CApplications■ Digital equipment■ Personal computers and peripherals■ Measuring instruments and medical equipment■ Telecommunications equipment■ Equipment requiring very high noise attenuationCircuit DiagramCircuit 1Circuit 2Circuit 3SpecificationsModel12-MMF-001-5-F12-MMF-003-5-G12-MMF-003-2-G12-MMF-006-5-G12-MMB-010-5-D12-MMB-015-5-E12-MMB-020-5-E12-MMB-030-5-ERated Voltage(@ 50/60Hz)120/250VACRatedCurrent1A3A6A10A15A20A30ALeakageCurrent (Max.)0.5mA5uA0.5mANote: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3Test voltage: 1500VAC one minute, line to groundInsulation resistance: 300 Mohm min. at 500VDCLeakage current: 0.7 mA max.Voltage drop: 1V max.Discharge time: 0.4 sec. max.Weight: 6.0 ounces (170 grams)CircuitDiagram312FigureABCDTemperature Rise(Max.)30°C86 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Line <strong>Filters</strong>Dual Stage12-MMF & 12-MMB SeriesFigure AFigure B2.01(51)1.06 (27)2.52 (64)2.95 (75)3.70 (94)Figure CM4 THREAD (5X)Figure DM4 STUD (7X).25 (6.4) .37 (9.4) HOLE (4X)1.73 ± .03(44 ± 1)3.33(84.5)MAX3.74 ± .02(95 ± 0.5)4.13 MAX.(64)3.38 1.65(86) (42)2.36 ± .007(60 ± .2)1.52 (39)MAX0.75 ± .03 (19 ± 1)2.01 ± .02(51 ± .05)3.15 (99) MAX5.31 (135) MAX2.28 (58).71 (18)1.50 (38)7.09 (180)7.24 (184)7.95 (202)Dimensions in inches (mm)Common ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterNormal ModeOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeter<strong>Power</strong> Line <strong>Filters</strong>Insertion Loss (dB)Insertion Loss (dB)12010590756045301512-MMF-001;-003;-00612-MMF-006-5-G12-MMF-003-5-G12-MMF-003-2-G 12-MMF-001-5-F00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)1201059075604512-MMB-010;-015;-020;-03012-MMB-010-5-D 12-MMB-015-5-E12-MMB-020-5-E12-MMB-030-5-E301500.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)Insertion Loss (dB)12010590756045301512-MMF-001;-003;-00612-MMF-001-5-F12-MMF-006-5-G12-MMF-003-2-G12-MMF-003-5-G00.1 0.2 0.5 1 2 5 10 20 50120105907560453015Frequency (MHz)12-MMB-010;-015;-020;-03012-MMB-015-5-E12-MMB-020-5-E12-MMB-030-5-E00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)12-MMB-010-5-DSPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5887


<strong>Power</strong> Line <strong>Filters</strong><strong>Power</strong> Line <strong>Filters</strong>Three PhaseLow Current/High Performance62-PMB/63-PMF SeriesFeatures■ Excellent attenuation for high voltage impulse■ Effective for both balanced and unbalancedthree-phase loads■ Metal case provides effective <strong>EMI</strong> shielding■ Epoxy molded for internal component reliability■ Compact and economical■ Excellent filtering characteristics for both normaland common mode■ Various current ratings available: 3, 5, 8 and 16 Amps■ Safety agency approvals pending■ Operating temperature: -25°C to +85°C(including temperature rise, see graph on page 89)Applications■ Digital equipment■ Industrial equipment (UPS, invertersand converters)■ Automation equipment■ Computerized washing machinesCircuit Diagram62-PMB-050-6-12 (5 Amp Delta)LLC X C X C YLLLC XC YC YL63-PMF-030-8-14 and 63-PMF-080-8-14 (3 and 8 Amp Wye)L C XLC X C YLC X C YC YLC Y63-PMF-160-9-21 (16 Amp Wye)LLLC X C X C X C X C X C XLC YC YSpecificationsModelRated Voltage Rated Leakage Current Capacitance Inductance Temperature(@ 50/60Hz) Current (Max.) C Y C X (L 1 ) Rise (Max.)62-PMB-050-6-12250VAC5A0.6mA2200pF0.22uF115mH45°C63-PMF-030-8-1463-PMF-080-8-14420VAC3A8A1.0mA4700pF (4X)470uF (3X)1.0mH (4X)0.74mH (4X)30°C40°C63-PMF-160-9-2116A3.0mA0.015uF (2X)1.0uF (6X)1.2mH (4X)45°CNote: Test Voltage 1500VAC one minute, line to ground.Insulation Resistance: 300 MΩ min. at 500VDC.Voltage Drop: 1V max. at rated current.Weight: 8.82 ounces (250 grams) for 63-PMF-030-8-14 and 63-PMF-080-8-1419.4 ounces (550 grams) for 62-PMB-050-6-1251.5 ounces (1450 grams) for 63-PMF-160-9-2188 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Line <strong>Filters</strong>Three PhaseLow Current/High PerformanceTemperature Characteristics62-PMB/63-PMF Series62-PMB-050-6-12 (5 Amp)5 — .157(M4).865 (22)2.753(70).865 (22)3.460 3.539(88) (90).039 (1)* General .944 (24)tolerance±.020 (0.5)1.376(35)63-PMF-030-8-14 and 63-PMF-080-8-14 (3 and 8 Amp)4.444 (113)4.050 (103)Fast-ontab #250.629(16)BL.708(18)BK63-PMF-160-9-21 (16 Amp)Fast ontab #2504 - .216(ø5.5) Hole.547(13.9)3.585 (91.2)Dimensions in inches (mm).547(13.9)2 - .197(ø5) Hole.983(25)BL1.809(46)BK2.045(52).208(5.3).350 (8.9)4.404(112).350 (8.9).350 (8.9)5.112 (130.0)5.702 (145 ± 0.5)6.292 (160).362(9.2)3.146(80.0±0.5)4.286(109)* Generaltolerance±..059 (1.5)1.494 (38)2.359 (60)Fast ontab #250(Groundtab).708(18)<strong>Power</strong> Line <strong>Filters</strong>Common Mode62-PMB-050-6-12 (5 Amp)Normal Mode62-PMB-050-6-12 (5 Amp)63-PMF (3, 8 and 16 Amp)63-PMF (3, 8 and 16 Amp)63-PMF-160-9-2163-PMF-160-9-2163-PMF-030-8-1463-PMF-080-8-1463-PMF-030-8-1463-PMB-050-8-1263-PMF-080-8-1463-PMB-050-8-12SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5889


<strong>Power</strong> Line <strong>Filters</strong>Three Phase13-PWF/PWL/PWB SeriesFeatures■ Excellent attenuation for high voltage impulse■ Effective for both balanced and unbalancedthree-phase loads■ Metal case provides effective <strong>EMI</strong> shielding■ Epoxy molded for internal component reliability■ Suitable for both Wye and Delta connectionCircuit DiagramCircuit 1AA'■ Excellent filtering characteristics for both normaland common mode■ Operating temperature: -40°C to +85°CBB'■ Designed for 3-phase 4-line power supply systemsApplications■ Digital equipmentCC'<strong>Power</strong> Line <strong>Filters</strong>■ Industrial equipment (UPS, invertersand converters)■ Automation equipment■ Computerized washing machinesNGCircuit 2AN'A'BB'CC'SpecificationsNGN'ModelRated Voltage(@ 50/60Hz)RatedCurrentLeakageCurrent (Max.)CircuitDiagramFigureTemperature Rise(Max.)13-PWF-005-12-H13-PWL-005-12-C13-PWF-010-12-H13-PWL-010-12-C13-PWB-010-12-D13-PWB-015-12-D13-PWB-020-12-D13-PWB-025-12-D13-PWB-030-12-D440/250VAC5A10A15A20A25A30A1.5mA12ABABC30°CNote: Test Voltage 1500VAC one minute, line to ground.Insulation Resistance: 300 MΩ min. at 500VDC.Voltage Drop: 1V max. at rated current.90 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Line <strong>Filters</strong>Three PhaseFigure B13-PWF/PWL/PWB SeriesFigure AFigure C2.0 (51)3.9 (98.5)Dimensions in inches (mm)5.3 (135)Common ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterNormal ModeOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeter<strong>Power</strong> Line <strong>Filters</strong>Insertion Loss (dB)807060504030201013-PWF-005;-010;-PWL-005;-010;-PWB-01013-PWF-005-12-H13-PWL-005-12-C13-PWB-010-12-D13-PWF-010-12-H13-PWL-010-12-CInsertion Loss (dB)807060504030201013-PWF-005;-010;-PWL-005;-010;-PWB-01013-PWB-010-12-D13-PWF-005-12-H13-PWL-005-12-C13-PWF-010-12-H13-PWL-010-12-CInsertion Loss (dB)807000.1 0.2 0.5 1 2 5 10 20 50605040302010Frequency (MHz)13-PWB-015;-020;-025:-03013-PWB-015-12-D13-PWB-020-12-D13-PWB-025-12-D13-PWB-030-12-DInsertion Loss (dB)00.1 0.2 0.5 1 2 5 10 20 508070605040302010Frequency (MHz)13-PWB-015;-020;-025:-03013-PWB-015-12-D13-PWB-020-12-D13-PWB-025-12-D13-PWB-030-12-D00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5891


<strong>Power</strong> Line <strong>Filters</strong>Three Phase13-PDF/PDL/PDB SeriesFeatures■ Excellent attenuation for high voltage impulse■ Effective for both balanced and unbalancedthree-phase loads■ Metal case provides effective <strong>EMI</strong> shielding■ Epoxy molded for internal component reliability■ Compact and economicalCircuit DiagramCircuit 1AA'■ Excellent filtering characteristics for both normaland common mode■ Operating temperature: -40°C to +85°CBB'■ Designed for 3-phase, 3-Delta connection system<strong>Power</strong> Line <strong>Filters</strong>Applications■ Digital equipment■ Industrial equipment (UPS, invertersand converters)■ Automation equipment■ Switching power suppliesCGCircuit 2ABC'A'B'CC'SpecificationsGModelRated Voltage(@ 50/60Hz)RatedCurrentLeakageCurrent (Max.)CircuitDiagramFigureTemperature Rise(Max.)13-PDF-005-11-J13-PDL-005-11-D13-PDF-010-11-J13-PDL-010-11-D13-PDB-010-11-D13-PDB-015-11-D13-PDB-020-11-D13-PDB-025-11-D13-PDB-030-11-D440/250VAC5A10A15A20A25A30A1.5mA12ABABC30°CNote: Test Voltage 1500VAC one minute, line to ground.Insulation Resistance: 300 MΩ min. at 500VDC.Voltage Drop: 1V max. at rated current.92 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


Figure B<strong>Power</strong> Line <strong>Filters</strong>Three PhaseØ .177 (4.5) (2X)2.00(51)13-PDF/PDL/PDB Series1.06(27)2.52 (64)2.95 (75)3.35 (85)Figure AØ .177 (4.5) (2X)Figure CM4THREAD(10X).25 (6.3).117 (4.5)2.52(64)2.91(74)3.35(85)3.31(84)3.74(95)4.13(105)1.42(36)Insertion Loss (dB)Oscillator50Ω2.00(51)3.15 (80)Common Mode80706050403020101 3Filter2 450ΩDimensions in inches (mm)50ΩLevelMeter13-PDF-005;-010; PDL-005;-010 PDB-01013-PDF-005-11-J13-PDL-005-11-D13-PDF-010-11-J13-PDL-010-11-D13-PDB-010-11-DInsertion Loss (dB)1.51(38.5)Normal Mode8070605040302010Oscillator50Ω50Ω2.00 (51)3.88 (98.5)5.31 (135)1 3Filter2 450Ω50ΩLevelMeter13-PDF-005;-010; PDL-005;-010 PDB-01013-PDB-010-11-D13-PDF-005-11-J13-PDL-005-11-D13-PDF-010-11-J13-PDL-010-11-D<strong>Power</strong> Line <strong>Filters</strong>00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)807060504030201013-PDB-015;-020;-025:-03013-PDB-015-11-D13-PDB-020-11-D13-PDB-025-11-D13-PDB-030-11-DInsertion Loss (dB)807060504030201013-PDB-015;-020;-025:-03013-PDB-030-11-D13-PDB-015-11-D13-PDB-020-11-D13-PDB-025-11-D00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)00.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5893


<strong>Power</strong> Line <strong>Filters</strong>Three PhaseHigh Performance13-PWB SeriesFeatures■ Excellent attenuation for high voltage impulse■ Metal case provides effective <strong>EMI</strong> shielding■ Epoxy molded for internal component reliability■ Excellent filtering characteristics for both normaland common mode■ Various current ratings available: from 5 to 150 Amps■ Operating temperature: -40°C to +85°CCircuit 1ACircuit DiagramA'■ Designed for 3-phase, 4-line power systemsApplications■ <strong>Power</strong> supplies for data systems■ Industrial equipment (UPS, invertersand converters)■ Automation equipmentBCNGB'C'N'<strong>Power</strong> Line <strong>Filters</strong>■ Telecommunications systems and equipmentCircuit 2ABCNGA'B'C'N'SpecificationsModelRated Voltage(@ 50/60Hz)RatedCurrentLeakageCurrent (Max.)CircuitDiagramTemperature Rise(Max.)13-PWB-005-12-A13-PWB-010-12-B13-PWB-020-12-B13-PWB-035-12-C13-PWB-050-13-C13-PWB-080-14-D13-PWB-100-14-D13-PWB-150-14-E440/250VAC5A10A20A35A50A80A100A150A4.5mA9.0mA20mA1230°CNote: Test Voltage 1500VAC one minute, line to ground.Insulation Resistance: 300 MΩ min. at 500VDC.Voltage Drop: 1V max. at rated current.94 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Line <strong>Filters</strong>Three PhaseHigh PerformanceFDHPM EIL13-PWB SeriesDimensionsKGNJBACDimensions in inches (mm)ModelABCDEFGHIJKMNPL13-PWB-005-12-A13-PWB-010-12-B13-PWB-020-12-B13-PWB-035-12-C13-PWB-050-13-C7.2 (184) 6.3 (160) 7.9 (202)9.6(243)8.7(220)10.3(261)2.4(60)3.1(81)1.7(44)3.8(96)3.5 (86)3.9(100)4.9(125).70 (18).98(25)2.3 (58)3.5(90)M4M61.5 (38)1.8(45)2.3(58)––2.9(74)–1.9(49)M4M6.25 x .37 (6.4 x 9.4).25 x .37 (6.4 x 9.5).25 x .38 (6.4 x 9.6).25 x .38 (6.4 x 9.7).25 x .38 (6.4 x 9.8)13-PWB-080-14-D13-PWB-100-14-D13-PWB-150-14-E13.9(354)12.6(320)15.1(384)3.9(99)6.1(155)7.3(185)7.5 (190) 8.7 (220)1.2(30)1.4 (35)3.9 (100)M82.4(62)M43.4(86)2.2(56)2.4 (61)M8.25 x .39 (6.4 x 9.9).25 x .36 (6.4 x 9.10).25 x .36 (6.4 x 9.11)Insertion Loss (dB)Common Mode12010590756045Oscillator50Ω1 3Filter2 450Ω13-PWB-005;-010;-020;-03513-PWB-020-12-A13-PWB-035-12-AFrequency (MHz)50ΩLevelMeter13-PWB-010-12-A3013-PWB-005-12-A1500.1 0.2 0.5 1 2 5 10 20 50Insertion Loss (dB)Normal Mode120105907560453015Oscillator50Ω50Ω1 3Filter2 450Ω13-PWB-005;-010;-020;-03513-PWB-010-12-A13-PWB-035-12-AFrequency (MHz)50ΩLevelMeter13-PWB-005-12-A13-PWB-020-12-A00.1 0.2 0.5 1 2 5 10 20 50<strong>Power</strong> Line <strong>Filters</strong>Insertion Loss (dB)1201059075604513-PWB-050;-080;-100;-15013-PWB-080-14-D13-PWB-100-14-D13-PWB-150-14-E13-PWB-050-13-C301500.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)Insertion Loss (dB)12010590756013-PWB-050;-080;-100;-15013-PWB-100-14-D 13-PWB-080-14-D13-PWB-050-13-C4513-PWB-150-14-E301500.1 0.2 0.5 1 2 5 10 20 50Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5895


<strong>Power</strong> Line <strong>Filters</strong>Three PhaseHigh Performance13-PDB SeriesFeatures■ Excellent attenuation for high voltage impulse<strong>Power</strong> Line <strong>Filters</strong>■ Metal case provides effective <strong>EMI</strong> shielding■ Epoxy molded for internal component reliability■ Excellent filtering characteristics for both normaland common mode■ Various current ratings available: from 5 to 200 Amps■ Operating temperature: -40°C to +85°C■ Designed for 3-phase, 3-line connection systemsApplications■ Digital equipment■ Industrial equipment (UPS, invertersand converters)Circuit 1ABCGCircuit 2ABCGCircuit DiagramA'B'C'A'B'C'SpecificationsModelRated Voltage(@ 50/60Hz)RatedCurrentLeakageCurrent (Max.)CircuitDiagramTemperature Rise(Max.)13-PDB-005-12-A13-PDB-010-12-A13-PDB-020-12-B13-PDB-035-12-B13-PDB-050-13-B13-PDB-080-13-C13-PDB-100-14-C13-PDB-150-14-C13-PDB-200-14-D440/250VAC5A10A20A35A50A80A100A150A200A4.5mA9.0mA20mA1230°CNote: Test Voltage 2250VDC one minute, line to ground.Insulation Resistance: 500MΩ.96 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Line <strong>Filters</strong>Three PhaseHigh PerformanceFDHMEPIL13-PDB SeriesDimensionsModel ABCDEFGHKIJGNJKMNBACDimensions in inches (mm)PL13-PDB-005-12-A13-PDB-010-12-A7.2(184)6.3(160)7.9(202)1.6(42)2.4(60)3.3(86).70(18)2.3(58)M41.5(38)–––M4.25 x .37 (6.4 x 9.4).25 x .37 (6.4 x 9.5)13-PDB-020-12-B13-PDB-035-12-B13-PDB-050-13-B13-PDB-080-13-C13-PDB-100-14-C13-PDB-150-14-C13-PDB-200-14-D9.6(243)13.9(354)8.7(220)12.6(320)10.3(261)15.1(384)2.3(58)2.5(66)2.7(70)6.1(155)3.9(100)7.3(185)7.5 (190) 8.6 (220).98(25)1.2(30)1.4 (35)3.5(90)3.9 (100)M6M82.3(58)2.4(62)M42.9(74)3.3(86)1.9(49)2.2(56)2.4 (61)M6M8.25 x .38 (6.4 x 9.6).25 x .38 (6.4 x 9.7).25 x .38 (6.4 x 9.8).25 x .39 (6.4 x 9.9).25 x .36 (6.4 x 9.10).25 x .36 (6.4 x 9.11).25 x .36 (6.4 x 9.12)Common ModeOscillator50Ω1 3Filter2 450Ω50ΩLevelMeterNormal ModeOscillator50Ω50Ω1 3Filter2 450Ω50ΩLevelMeter<strong>Power</strong> Line <strong>Filters</strong>Insertion Loss (dB)Insertion Loss (dB)12010590756045301512013-PDB-005;-010;-020;-03513-PDB-020-12-B13-PDB-035-12-B13-PDB-005-12-A13-PDB-010-12-A00 0.01 0.02 .1 1 10 20 30 60Frequency (MHz)13-PDB-050;-080;-100;-150;-20010513-PDB-050-13-B90756045301513-PDB-100-14-C13-PDB-080-13-C13-PDB-150-14-C13-PDB-200-14-D00 0.01 0.02 .1 1 10 20 30 60Frequency (MHz)Insertion Loss (dB)Insertion Loss (dB)12010590756045301513-PDB-005;-010;-020;-03513-PDB-010-12-A13-PDB-005-12-A13-PDB-035-12-B13-PDB-020-12-B00 0.01 0.02 .1 1 10 20 30 60Frequency (MHz)13-PDB-050;-080;-100;-150;-20012013-PDB-100-14-C10590756045301513-PDB-050-13-B13-PDB-200-14-D13-PDB-080-13-C13-PDB-150-14-C00 0.01 0.02 .1 1 10 20 30 60Frequency (MHz)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5897


Military/AerospaceMultisection <strong>Filters</strong>Military/Aerospace Multisection <strong>Filters</strong>Features■ High common and differential mode attenuation■ Standard designs up to 100 Amps■ Excellent insertion loss characteristics up to 1 GHz■ Voltage rating 115-250VAC and 400VDC up to 400 Hz■ Available to meet MIL-F-15733 and MIL-STD-461standards■ Available to meet TEMPEST and FCC requirements■ Custom designs availableApplications■ Military■ Commercial &military/aerospace■ Secured communications■ Switching power supplies■ Data processing equipmentTest SpecificationsThe High Performance <strong>Power</strong> Line <strong>Filters</strong> shown on pages99 through 105 are designed to meet the following criteria.The information shown can be used as a basis forfilter specifications. (Contact factory for additional details).OrderTest of Examination Test Method Post TestGroup Test or Test (Per MIL-STD-202) RequirementsIIA■ Ruggedized computers■ Radar■ Electronic warfare■ Ground/air weapon systems■ Satellites1 Voltage Drop Paragraph 4.6.8 of MIL-F-15733 Three percent of rated voltage max.2 Leakage Current UL 1283 Per applicable specification3 Temperature Rise MIL-F-15733 Paragraph 4.6.4 25°C max.4 Terminal Strength Method 211, Condition ANo evidence of loosening or rupture.5 lb. applied force. Line Cords: 35 Lbs.1 Shock, Medium Impact Method 213, Condition G Must pass DWV and Insertion Loss2 Vibration, High Frequency Method 204, Condition A Monitor for shorts or openIIB3 Thermal Shock Method 107, Test Condition A Pass 90% DWV IR to be 30% of initial4 HumidityMethod 107, Condition B, excepttemperature equals 25°CPass 90% DWV IR to be 30% of initialIII1 LifeMethod 108, Condition D 1.2 x Rated AC voltageat max. operating temp. or 1.4 x DC voltagePass 90% DWV insulation resistanceto be 30% of initial.98 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


Military/AerospaceMultisection <strong>Filters</strong>Insertion Loss52-600-001Insertion Loss (dB)80604020differentialmodecommon mode00.01 0.1 1 10 100 1000Frequency (MHz)52-600-002Circuit SchematicLINE LOAD80Insertion Loss (dB)60402000.01 0.1 1 10 100 1000Frequency (MHz)Dimensions52-600-00152-600-002common modedifferential modeSWITCHFUSECONNECTOR1.250(31.75).625(15.8)1.68(42.67).215(5.46)2.500(63.50).240(6.10)#6-32 THREADEDINSERTS (4 PL.)(3.50-32)3.88(98.55).250 Fast-on tabs (3 PL.)2.98(75.70).250(6.35)2.500(63.50)1.250(31.75).03 R.4 PLCHASSISMOUNTINGHOLE2.120 ± .010(53.85)Dimensions in inches (mm)Military/Aerospace Multisection <strong>Filters</strong>DCR. LeakageCurrent Voltage Temperature max. Current ModeModel Rating Rating Rating (ohms) (max.) (max.)Minimum Insertion Loss(db) Per MIL-STD-22050K 150K 300K 1M 10M 100M 1G52-600-001 5A 120/240VAC -40°C to +65°C .20 1 mA COMM 33 65 80 80 80 80 6060 Hz DIFF 37 65 80 80 80 – –52-600-002 10A 120/240VAC -40°C to +65°C .10 1 mA COMM – 50 70 80 80 70 6060 Hz DIFF 25 50 75 80 80 – –Consult factory for UL/CSA approval availability.SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-5899


HIGH PERFORMANCEMilitary/Aerospace<strong>Power</strong> Line <strong>Filters</strong> for C.O.T.S./Multisection TEMPEST Applications <strong>Filters</strong># 52-600-00152-600-002Insertion Loss52-523-00280Circuit Schematic52-523-002LINE LOADInsertion Loss (dB)60402000.01 0.1 1 10 100 1000Frequency (MHz)Dimensions52-523-002Military/Aerospace Multisection <strong>Filters</strong>.600(15.24)2.010(51.05).750(19.05).375(9.52).250(6.35).250(6.35)3.000(76.2)#6-32 THDEDINSERT 4 PLCS.(3.50-32)FUSE-HOLDER4.00(101.6)DCR LeakageCurrent Voltage Temperature max. Current ModeModel Rating Rating Rating (ohms) (max.) (max.)PLUG.625(15.8)1.25(31.75).875(22.2)1.75(44.4)3.50(88.9).875(22.2)Dimensions in inches (mm)Minimum Insertion Loss(db) Per MIL-STD-22050K 150K 300K 1M 10M 100M 1G52-523-002 5A 120/240VAC -40°C to +65°C .25 1 mA COMM – 55 60 80 80 70 6060 Hz DIFF – 50 60 80 80 – –Consult factory for UL/CSA approval availability.100 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


Military/AerospaceMultisection <strong>Filters</strong>Insertion Loss1212-0502Insertion Loss (dB)8060402000.01 0.1 1 10 100 1000Frequency (MHz)Circuit Schematic1212-0502Dimensions1212-0502.418(10.62).500(12.7).209(5.31).219 TYP.(5.56).656(16.41).875(22.23)1.250(31.75)1.437 ± .031(36.50 ± .78).187(4.75)1.000(25.4).125 6-PLCS.(3.18 ± .00)1.187 ± .015(30.15 ± .38).594± .031± (.78).281 ± .031(7.14 ± .78)1.125(28.58)DCR LeakageCurrent Voltage Temperature max. Current C xModel Rating Rating Rating (ohms) (max.) Value.710(18.03).055 TYP.(1.40).105 TYP.(2.67).120 TYP.(3.05)MOUNTINGSURFACE.032(.81)Dimensions in inches (mm)Minimum Insertion Loss(db) Per MIL-STD-22010M 100M 500M 1GMilitary/Aerospace Multisection <strong>Filters</strong>1212-0502 10A 350VDC -55°C to +125°C .01 1 mA 5000pF 20 65 70 70240VAC 60 HzConsult factory for UL/CSA approval availability.SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58101


Military/AerospaceMultisection <strong>Filters</strong>Secure Communications<strong>Spectrum</strong>'s electromagnetic compatibility expertise inthe secure communication or “TEMPEST” arena is representedby this group of high performance filters. Theseunits are especially well suited for use in MIL-STD-461applications to reduce conducted emissions. The filtersare manufactured with glass sealed terminalsand connectors.Features■ Excellent insertion loss profile■ Available for DC & AC applications up to 400 Hz■ Available for 3-14 Amp applications■ Custom systems can be designedto your specific needs■ QPL to MIL-F 15733/63-0001Filter Schematic AFilter Schematic BLINE LOADACBACBMilitary/Aerospace Multisection <strong>Filters</strong>Dimensions52-378-0022.50(63.50)1.500(38.10).750(19.05)2.50(63.50)1.25(31.75)#8-32 UNC THD. INSERTS(4.17-32).350 DEEP, 2 PLACES(8.89)1.75(44.45)CONNECTOR #8001-14S-7P-A3MATES WITH MS-3106-14S-7SDimensions in inches (mm)Insertion Loss (dB)80604020ACBLINE LOADInsertion Loss52-378-002, -004 MIL-STD-22000.01 0.1 1 10 100 1000Frequency (MHz)ACBDCR LeakageCurrent Voltage Temperature max. CurrentModel Rating Rating Range (ohms) (max.) SchematicMinimum Insertion Loss (db)50 150 300 1 10 100 1KHz KHz KHz MHz MHZ MHZ GHz52-378-001 3 Amps 240VAC 60 Hz -55°C to 85°C .3 50 mA A 30 60 70 80 80 70 70Line to Line52-378-002 5 Amps 240VAC 60 Hz -55°C to 85°C .2 50 mA B 24 64 70 80 80 70 70Line to Line52-378-004 5 Amps 240VAC 60 Hz -55°C to 85°C .2 50 mA A 34 64 70 80 80 70 70Line to Line52-378-005 3 Amps 240VAC 60 Hz -55°C to 85°C .3 50 mA B 40 70 80 80 80 70 60Line to Line102 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>Power</strong> Military/AerospaceLine <strong>Filters</strong>for Multisection Secure Communications<strong>Filters</strong>Insertion LossInsertion Loss (dB)8060402052-387-010, -003 MIL-STD-22052-409-001 MIL-STD-22052-387-010,-003 MIL-STD-22052-409-001MIL-STD-22000.01 0.1 1 10 100 1000Frequency (MHz)Filter Schematic CFilter Schematic DLINE LOADACBLINE LOADACACBACBB3 Phase and 400 Hz models available.Please consult the factory.Dimensions2.50(63.50)1.500(38.10).750(19.05)2.50(63.50)1.25(31.75)Figure 1 Figure 21.25(31.75)3.00(76.20)Filter Schematic E2.50(63.50)1.500(38.10).750(19.05)2.50(63.50)1.25(31.75)ACBLINE LOAD.625(15.87)#8-32 UNC(4.17-32)STUD1.75(44.45)ACBMilitary/Aerospace Multisection <strong>Filters</strong>#8-32 UNC THD. INSERTS(4.17-32).350 DEEP, 2 PLACES(8.89)CONNECTOR #8001-10SL-3PN-FP-A3MATES WITH MS-3106-10SL-3SDimensions in inches (mm)#8-32 UNC THD. INSERTS(4.17-32).350 DEEP, 2 PLACES(8.89)CONNECTOR #8001-14S-7P-A3MATES WITH MS-3106-14S-7SDimensions in inches (mm)DCR LeakageCurrent Voltage Temperature max. CurrentModel Fig. Rating Rating Range (ohms) (max.) Sch. ModeMinimum Insertion Loss (db)50 150 300 1.0 10 100 1KHz KHz KHz MHz MHz MHz GHz52-387-010 1 10 Amps 240VAC 60 Hz -55°C to 85°C .2 50 mA C common 24 60 70 80 80 70 70Line to Line52-387-012 1 5 Amps240VAC 400 Hz -55°C to 85°C .2 5 mA DLine to Linecommon 34 64 70 80 80 70 70differential 30 30 70 80 80 – –52-409-001 2 14 Amps240VAC 60 HzLine to Line-55°C to 85°C .04 50 mA E common 14 30 45 80 80 70 60SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58103


Military/AerospaceMultisection <strong>Filters</strong>Military/Aerospace Multisection <strong>Filters</strong>Secure CommunicationsFeatures■ Meets applicable sections of MIL-F-15733■ Excellent performance■ Integral IEC connector■ Available with integral fused IEC connectorand two pole switch■ Current ratings to 15 Amps■ Custom designs available■ Designed to meet TEMPEST requirementsElectrical SpecificationsRated current ranges .................. 3, 6, 10, 15 AmpsRated voltage............................. 115-250VACOperating frequency................... 50-60 HzMaximum leakage current@115VAC 60 Hz............ 1.2 mA@250VAC 50 Hz............ 2.5 mATest voltageLine-to-Line.................... 1450VDCLine-to-Ground............... 2250VDCInsertion LossPart Numbering System:760 - A 06 QModelCurrent Rating:3, 6, 10, 15 AmpsTerminal Style:A=.25 Quick ConnectC=Wire Leads (4" min.)Series: 760; 761 or 762Insertion Loss (dB)806040760, 761, 762 - 3, 6 Ampscommon mode20differential mode00.01 0.1 1 10 100 1000Frequency (MHz)Insertion Loss (dB)806040760, 761, 762 - 10, 15 Ampscommon mode20differential mode00.01 0.1 1 10 100 1000Frequency (MHz)Common Mode (CM) is tested in a 50 ohm system with all lines tied together on the line and load sides of the filter.Differential Mode (DM) is tested in a 50 ohm system using a 180˚ phase splitter on both sides of the filter.104 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


Military/AerospaceMultisection <strong>Filters</strong>Dimensions - 760 Series.55 (13.97)SeriesCurrentFilter DimensionsRating(Amps) A B CA7603, 610, 152.25 3.00 1.88(57.15) (76.20) (47.75)5.50 3.15 2.10(139.70) (88.01) (53.34)1.23(31.24).13 (3.30)B1.332(33.83).67 (42.41).95 (24.13)8-32 Inserts (4 Places)1.312(33.32).66 (16.67)Dimensions - 761, 762 SeriesCC3.00(76.2)TERMINATIONSTYLE “A”SeriesTERMINATIONSTYLE “C”761, 762 3, 6761 10, 15762 10, 15Dimensions in inches (mm)CurrentFilter DimensionsRating(Amps) A B C2.55 2.97 1.88(64.77) (75.43) (47.75)5.50 3.15 2.10(139.70) (88.01) (53.34)5.75 3.15 2.10(146.05) (88.01) (53.34)Military/Aerospace Multisection <strong>Filters</strong>0.20(5.08)1.30(33.02)1.30(33.02)0.20 (5.08)A0.80(20.32)6-32 UNC-2B(6 Places)1.875(47.62)3.67(93.21)0.80(20.32)BSwitch Omittedin Model 761Switch Omittedin Model 761.40 (10.16).55 (13.97)3, 6, 10, AMPFRONT PANEL15 AMPFRONT PANELDimensions in inches (mm)SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58105


Custom/ApplicationSpecific <strong>Filters</strong><strong>Spectrum</strong><strong>Control</strong> will address virtually any requirement fora custom power product. Our many years of experience inproviding <strong>EMI</strong>/RFI solutions has allowed us to satisfy bothglobal EMC regulations and time-to-market constraints.<strong>Spectrum</strong> <strong>Control</strong>’s engineering expertise and verticalintegration reduces your speed-to-market, as well assaves you money.Features/Benefits■ Incorporates filtering and custom circuitry into oneCustom/Application Specific <strong>Filters</strong>design package■ SCI’s EMC Test Facility will define compliance issues■ Current and voltage ratings to meet your specifications■ Specific circuit designs to accommodate your application■ Reduces your development time■ Increases speed-to-market■ Designed to perform in industrial environments■ Designs incorporate filtering for both common anddifferential modes■ Ensures reliability (all parts are 100% tested)■ Designed to meet agency approvalsOptions■ <strong>EMI</strong> filtering■ Transient protection■ Circuit breaker protection■ Voltage cut-off■ Reverse polarityPerformance CharacteristicsInsertion loss rangeCurrent ratings (max.)Voltage ratings (max.)■ <strong>Power</strong> distribution■ Indicator lights■ Leads or studs■ Agency approvalsEffective filtering from 10 KHz to10 MHz with proper installationup to 500 Amps400VDC and 240VAC standard,custom ratings availableLeakage current ratings Varies, low leakage designsavailableTemperature-25° C to +85° CSpecify your required current rating, voltage ratingsand capacitance value.106 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


<strong>EMI</strong> FilteringCustom/ApplicationSpecific <strong>Filters</strong>CircuitBreakerProtection<strong>Power</strong>DistributionMultipleOutlets<strong>Power</strong> Distribution<strong>Power</strong> Entry<strong>EMI</strong> FilteringTransient ProtectionThree-Phase Delta <strong>EMI</strong> FilterPigtail LeadsRuggedConstructionLow Voltage Cut-off-48 VDC-60 VDCUL RecognizedComplies to UL 1459CSA CertifiedCustom/Application Specific <strong>Filters</strong>High CurrentTerminal BlockCustom Ground PlateSPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58107


Custom/ApplicationSpecific <strong>Filters</strong><strong>Spectrum</strong> <strong>Control</strong>'s design teams can help transforma functional electronic design into an easy to install<strong>EMI</strong> filtered package containing all required components.We will define your EMC problem through our testfacilities, develop a filter solution and manufactureproduct to meet your schedule.By designing and manufacturingyour entire assembly,<strong>Spectrum</strong> <strong>Control</strong> will:■ Reduce development time■ Combine your design into a compact, filtered package■ Simplify installation, saving time and money■ Increase productivity■ Complement your inventory control program■ Reduce your vendor baseCustom/Application Specific <strong>Filters</strong>108 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


Custom/ApplicationSpecific <strong>Filters</strong>Single Line <strong>Filters</strong><strong>Power</strong> Distribution Units<strong>Power</strong>Line <strong>Filters</strong>FilteredTerminal BlocksPSM High CurrentSurface Mount <strong>Filters</strong>Custom/Application Specific <strong>Filters</strong>Remote control options available with intelligent powerdistribution units.SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58109


Part Number Index<strong>Spectrum</strong> part # . . . . . . . . . . .Page10-BPF-XXX-2-X . . . . . . . . . . . . . .3210-BPF-XXX-5-X . . . . . . . . . . . . . .3010-BPL-XXX-5-X . . . . . . . . . . . . . .3811-MPC-XXX-X-X . . . . . . . . . . . . .5812-MMB-XXX-5-X . . . . . . . . . . . . .8212-MMB-XXX-5-X . . . . . . . . . . . . .8612-MMB-XXX-11-X . . . . . . . . . . . .8412-MMF-XXX-5-X . . . . . . . . . . . . .8212-MMF-XXX-5-X . . . . . . . . . . . . .8612-MMF-XXX-11-X . . . . . . . . . . . .8412-PMB-XXX-DC-X . . . . . . . . . . . .7812-PMB-XXX-X-X . . . . . . . . . . . . .7612-PMF-XXX-DC-X . . . . . . . . . . . .7812-PMF-XXX-2-X . . . . . . . . . . . . .6612-PMF-XXX-5-X . . . . . . . . . . . . .7212-PML-XXX-X-X . . . . . . . . . . . . .6613-PDB-XXX-XX-X . . . . . . . . . . . .9213-PDB-XXX-XX-X . . . . . . . . . . . .9613-PDF-XXX-XX-X . . . . . . . . . . . .9213-PDL-XXX-XX-X . . . . . . . . . . . .9213-PWB-XXX-XX-A . . . . . . . . . . . .9413-PWB-XXX-XX-B . . . . . . . . . . . .9413-PWB-XXX-XX-C . . . . . . . . . . . .9413-PWB-XXX-14-D . . . . . . . . . . . .9413-PWB-XXX-XX-E . . . . . . . . . . . .9413-PWB-010-12-D . . . . . . . . . . . . .9013-PWB-015-12-D . . . . . . . . . . . . .9013-PWB-020-12-D . . . . . . . . . . . . .9013-PWB-025-12-D . . . . . . . . . . . . .9013-PWB-030-12-D . . . . . . . . . . . . .9013-PWF-XXX-XX-X . . . . . . . . . . . .9013-PWL-XXX-XX-X . . . . . . . . . . . .9052-226-001 . . . . . . . . . . . . . . . . . .2052-226-002 . . . . . . . . . . . . . . . . . .2052-226-004 . . . . . . . . . . . . . . . . . .2052-226-006 . . . . . . . . . . . . . . . . . .2052-226-008 . . . . . . . . . . . . . . . . . .2052-226-009 . . . . . . . . . . . . . . . . . .2052-226-011-XX . . . . . . . . . . . . . . .1252-226-015 . . . . . . . . . . . . . . . . . .20<strong>Spectrum</strong> part # . . . . . . . . . . .Page52-226-016-XX . . . . . . . . . . . . . . .1652-226-019-XX . . . . . . . . . . . . . . .1852-226-020-XX . . . . . . . . . . . . . . .1452-226-021-XX . . . . . . . . . . . . . . .1252-226-026-XX . . . . . . . . . . . . . . .1652-226-029-XX . . . . . . . . . . . . . . .1452-226-031-XX . . . . . . . . . . . . . . .1252-226-036-XX . . . . . . . . . . . . . . .1652-226-037-XX . . . . . . . . . . . . . . .1852-226-041-XX . . . . . . . . . . . . . . .1252-226-046-XX . . . . . . . . . . . . . . .1652-267-002 . . . . . . . . . . . . . . . . . .2052-267-003 . . . . . . . . . . . . . . . . . .2052-267-008 . . . . . . . . . . . . . . . . . .2052-267-009 . . . . . . . . . . . . . . . . . .2052-267-010 . . . . . . . . . . . . . . . . . .2052-267-011 . . . . . . . . . . . . . . . . . .2052-267-012 . . . . . . . . . . . . . . . . . .2052-378-XXX . . . . . . . . . . . . . . . .10252-387-XXX . . . . . . . . . . . . . . . .10352-409-XXX . . . . . . . . . . . . . . . .10352-523-002 . . . . . . . . . . . . . . . . .10052-600-XXX . . . . . . . . . . . . . . . . .9952-1013-XXX . . . . . . . . . . . . . . . .2360-BHP-XXX-X-X . . . . . . . . . . . . .5660-BHS-XXX-X-X . . . . . . . . . . . . .2860-BPF-XXX-X-X . . . . . . . . . . . . .2660-BPL-XXX-X-X . . . . . . . . . . . . . .3660-BPP-XXX-X-X . . . . . . . . . . . . .5460-BPR-XXX-X-X . . . . . . . . . . . . .2460-BPS-XXX-X-X . . . . . . . . . . . . .2460-SPL-XXX-X-X . . . . . . . . . . . . . .3460-SPR-XXX-X-X . . . . . . . . . . . . .4060-SPS-XXX-X-X . . . . . . . . . . . . .4061-MPC-XXX-X-XX . . . . . . . . . . . .5262-AFC-XXX-X-XX . . . . . . . . . . . .6062-AFL-XXX-X-XX . . . . . . . . . . . . .6062-LMF-XXX-X-XX . . . . . . . . . . . .6862-LMB-XXX-X-XX . . . . . . . . . . . .6862-MMF-XXX-X-XX . . . . . . . . . . . .80<strong>Spectrum</strong> part # . . . . . . . . . . .Page62-PMB-XXX-5-XX . . . . . . . . . . . .7062-PMB-XXX-6-XX . . . . . . . . . . . .8862-PMB-XXX-X-XX . . . . . . . . . . . .7462-PMF-XXX-5-XX . . . . . . . . . . . .7062-PML-XXX-X-XX . . . . . . . . . . . .6462-PPF-XXX-X-XX . . . . . . . . . . . .6262-PQF-XXX-X-XX . . . . . . . . . . . .6262-PRF-XXX-X-XX . . . . . . . . . . . .6263-PMF-XXX-8-XX . . . . . . . . . . . .8863-PMF-XXX-9-XX . . . . . . . . . . . .8864-BFF-XXX-X-X . . . . . . . . . . . . . .4264-BFS-XXX-X-X . . . . . . . . . . . . .4264-BSF-XXX-X-XX . . . . . . . . . . . .4664-SSF-XXX-X-XX . . . . . . . . . . . .4665-BFF-XXX-X-X . . . . . . . . . . . . . .4265-BFS-XXX-X-X . . . . . . . . . . . . .4265-BSF-XXX-X-XX . . . . . . . . . . . .4665-SSF-XXX-X-XX . . . . . . . . . . . .4666-BFF-XXX-X-X . . . . . . . . . . . . . .4466-BFS-XXX-X-X . . . . . . . . . . . . .4466-BFS-XXX-X-X . . . . . . . . . . . . .4466-BSF-XXX-X-XX . . . . . . . . . . . .4866-SSF-XXX-X-XX . . . . . . . . . . . .4867-BFF-XXX-X-X . . . . . . . . . . . . . .4467-BFS-XXX-XX . . . . . . . . . . . . . .4467-BSF-XXX-X-X . . . . . . . . . . . . .4867-SSF-XXX-X-X . . . . . . . . . . . . .4868-BSF-XXX-X-XX . . . . . . . . . . . .50760-XXXX . . . . . . . . . . . . . . . . . .106761-XXXX . . . . . . . . . . . . . . . . . .106762-XXXX . . . . . . . . . . . . . . . . . .1061212-0502 . . . . . . . . . . . . . . . . . .101Appendix110SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


NotesAppendixSPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58111


NotesAppendix112SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


Design Inquiry FormRequest for Quote/Custom Design FormCompany nameName/TitleAddressCity State ZipPhone ( ) Fax ( )Target priceAnticipated yearly usageLife of programCustomer Time Line (fill in dates):QuotationPrototypeFirst ArticleProduction Start UpProduct Offering Suggested for this Application:(Check appropriate response)Custom Assembly (Multi-Section Filter)Custom Assembly (<strong>Power</strong> Distribution Unit)<strong>Power</strong> Entry FilterHigh Current Single/Dual Line FilterPhysical ParametersMechanical Requirements:Maximum Dimensions:Length (inches)Height (inches)WidthPlease include drawing or sketch, if available.Electrical ParametersElectrical Terminations:LINE SIDELOAD SIDEConnectorStudsPigtails/leadsConnectorTerminalBlockOtherOutlet/Inlet Type: Duplex SingleIEC Vendor P/NOtherACRequirements: 120VAC 250VACOtherFrequency(Hz): 50 400Current(Amps):LeakageCurrent:DCRequirements:Insertion LossRequirements:Accessories60 OtherCurrent/ phase (Amps):Phase requirements:SingleThreeDelta (3 wires)Wye (4 wires)OtherVoltage:Current (Amps):mA (max.)Common mode (load) (no load)Differential mode (no load)SurgeSuppression: No YesDefineCircuitBreaker: Yes NoCurrent RatingVoltage RatingVendorP/NSwitches: Lighted Non-lightedRemoteNoneAgencyApprovals: UL CECSAOtherTUVAppendixSPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58113


As A <strong>Control</strong> Products & Systems Company, westrive to meet our customers’ needs by providing greatercomponent and system solutions to their design problems.Our family of interference, power and microwave productsis now the broadest line in the industry. These engineeringdriven products deliver unmatched performance in thehigh frequencies common to new applications.To satisfy the increased demand that correspondswith our growth, we’ve conducted a major manufacturingexpansion. This additional manufacturing capacity involvesall of our facilities and is highlighted by our new plants inJuarez, Mexico and Guang Dong, China. These expandedfacilities produce components and systems for all of ourgroups and have received numerous positive customer audits.A<strong>Control</strong> ProductsSystems Company&GlobalManufacturingSignal & <strong>Power</strong> Integrity GroupAs a vertically integrated producer of ceramic capacitorsand filters, we continue to provide the widest range ofdiscrete <strong>EMI</strong> filters, filtered connectors, ferrite inductorsand filtered power products. In addition, we haveextended our ceramic technology to develop ourline of wireless components.■ Low Pass <strong>EMI</strong> <strong>Filters</strong>■ Filtered Terminal Blocksand Filter Plates■ Filtered Connectors■ Datacom Connectors■ Ferrite InductorsFrequency <strong>Control</strong> GroupIn order to expand our line of microwave products,we recently acquired FSY Microwave, including allproducts and design expertise. The new <strong>Spectrum</strong>FSY Microwave family of SPECWAVE componentsand systems provides a wide range of frequencycontrol solutions.■ Bandpass <strong>Filters</strong>and Duplexers■ Patch AntennaElements■ Waveguide <strong>Filters</strong>■ Lumped Element <strong>Filters</strong>■ Ceramic Capacitors■ Single Line <strong>Filters</strong>■ Filtered Terminal Blocks■ <strong>Power</strong> Entry Modulesand <strong>Power</strong> Line <strong>Filters</strong>■ Multisection <strong>Filters</strong>■ Suspended Substrates■ Cavity <strong>Filters</strong>■ Coaxial Tubular <strong>Filters</strong>■ Microwave CustomAssemblies<strong>EMI</strong> <strong>Filters</strong>and Filtered<strong>Power</strong>ProductsFrequency<strong>Control</strong>Products<strong>Power</strong> Management Systems GroupSeveral years ago, we began to apply ourfundamental filtering expertise to improve powermanagement. The result is a complete line ofstandard, yet customizable power distributionunits and remote management systems.■ SMARTstart AC/DC Intelligent<strong>Power</strong> Distribution Units■ SHARPstart AC/DC <strong>Power</strong> Distribution Units■ Custom Commercial Assemblies<strong>Power</strong>ManagementSystemsCERTIFIED114SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58


Our new Check Stock system allows you to gather instantinformation regarding a particular component’s inventorystatus at <strong>Spectrum</strong> <strong>Control</strong>’s network of authorized distributors.Selecting the Check Stock icon will provide you with distributornames, part numbers, quantity on hand, online orderingcapability and the last date the inventory was updated forthat particular component. Use Check Stock to improve yourorganization’s efficiency by simplifying inventory managementand reducing inventoryWe’ve made finding the right product for your applicationeasier than ever. By using our new online catalog you can tellus the performance parameters you need and we’ll help youlocate the appropriate product. You start by identifying yourmechanical package, add some required electrical characteristicsand we’ll show you applicable standard part numbers and howthey compare to your specifications.New Design Direct allows you to work with our engineers in acollaborative online effort to develop a custom solution tailoredto your specific needs. After registering on our site, you’ll beable to create and track your project, entirely online. As ourengineering team makes changes to your project, you’ll receivean e-mail with a direct link to see the current status and providefeedback. Designing a custom solution has never been easier.To see all of our new online <strong>tool</strong>s,come visit us @ www.spectrumcontrol.comSPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.comSPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58115


A<strong>Control</strong> ProductsSystems Company&Signal & <strong>Power</strong>Integrity ProductsFerrite beads & inductorsSurface mount filtersDiscrete <strong>EMI</strong> filtersFilter platesFilter connectorsGaskets & shieldingCeramic capacitorsSingle line filtersFiltered terminal blocks<strong>Power</strong> entry & power line filtersMilitary/multisection filtersEMC testingwww.spectrumcontrol.comCorporate Headquarters8031 Avonia RoadFairview, Pennsylvania 16415Phone: 814-474-2207Fax: 814-474-2208Signal & <strong>Power</strong> Integrity8061 Avonia RoadFairview, Pennsylvania 16415Phone: 814-474-1571Fax: 814-474-3110Sales OfficesNORTH AMERICA6798 Oak Hall LaneColumbia, Maryland 21045Phone: 301-916-2919Fax: 301-916-2910NEWNEWEUROPE<strong>Spectrum</strong> <strong>Control</strong> GmbHHansastrasse 691126 Schwabach, GermanyPhone: (49)-9122-795-0Fax: (49)-9122-795-58Represented or Distributed by:Frequency <strong>Control</strong> ProductsResonatorsBandpass filters & duplexersPatch antenna elementsWaveguide filtersCombinersCouplersDuplexer-LNA assembliesLumped element filtersSuspended SubstratesCavity filtersCoaxial tubular filtersMicrowave custom assembliesTower mount amplifierswww.specwave.com<strong>Power</strong> Management SystemsAC/DC power distribution units& remote reboot power management systemsCustom assemblies<strong>Power</strong> stripswww.specpower.comCHINA<strong>Spectrum</strong> <strong>Control</strong> LimitedRoom 73-78 - 2nd FloorSino Industrial Plaza9 Kai Cheung RoadKowloon BayKowloon, Hong KongPhone: (011)-852-2197-9912Fax: (011)-852-2750-9663For additional information regarding<strong>Spectrum</strong> <strong>Control</strong>, our full line of<strong>EMI</strong> filtering and power productsand our many new products,call us or contact our Website athttp://www.spectrumcontrol.com<strong>Spectrum</strong> <strong>Control</strong>, Inc. reservesthe right to alter the specificationsprovided in this publication.Consult factory for currentspecifications.CERTIFIEDNEWAHA 12/03 20M 27-0027-0046 © <strong>Spectrum</strong> <strong>Control</strong>, Inc. Printed in U.S.A.