Optimus L-band Matrix Router - ETL Systems
Optimus L-band Matrix Router - ETL Systems
Optimus L-band Matrix Router - ETL Systems
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Model Number: 21150RF Engineeringand Custom Build<strong>Optimus</strong> L-<strong>band</strong> <strong>Matrix</strong> <strong>Router</strong>Configurable as quad 4 x 16, dual 4 x 32 or single 4 x 64 matrices with remote PC andIRD control<strong>ETL</strong>’s new <strong>Optimus</strong> matrix providescompact form factor, flexibleconfigurations, hot-swap of activecomponents, and remote controlvia a PC and / or from IRD’s via13/18V 22KHz tone.Rear View of Model 21150 <strong>Optimus</strong> <strong>Matrix</strong>The matrix comprises 4 RF switch cards plus an input module which are combined toprovide a shelf with quad 4x16, dual 4x32, or a single 4x64 matrix in a 4U high 19” shelf.The RF modules can be hot-swapped, as can the dual redundant PSU’s and CPU.<strong>Optimus</strong> also provides LNB Powering which can be remotely (via Ethernet port) set to0/13/18V with 22KHz tone. LNB current monitoring can also be done via the Ethernetport. A dry contact alarm port is provided on the rear panel for PSU failure.Front View of Model 21150 <strong>Optimus</strong> <strong>Matrix</strong>V 1.0.1E&OE
Model Number: 21150<strong>Optimus</strong> L-<strong>band</strong> <strong>Matrix</strong> <strong>Router</strong>RF Engineeringand Custom BuildTechnical specifications and operating parametersPRELIMINARY SPECIFICATIONSRF ParametersCapacity RF switch cards are 4 input x 16output matrices. The RF inputcard is configured to give up to4 4x16 matrices; or 2 4x32; or a4x48; or 4x64 systemDistributive or Fan-outFrequency RangeOne input may go to manyoutputs850-2150 MHz (L-<strong>band</strong>)AC PowerLNB PowerPSUHot-swap PSUPower85-264Vac 47-63Hz, fused 2A0/13/18V DC 400 mA,switchable & 22KHz tone on/off on RF in portsDual redundant, dual mainsinletsYesGain0 dB ± 2 dB nominal, meanacross <strong>band</strong>Gain vs. FrequencyFlatnessNoise FigureGroup Delay± 2.5 dB17 dB at max gain setting21 dB at unity gain setting25 dB at min gain setting≤1.0 nsPk-pk, any 60MHzsegmentInput ConnectorInput ImpedanceOutput ConnectorOutput ImpedancePhysicalBNC, F-type or SMA50Ω or 75ΩBNC, F-type or SMA50Ω or 75ΩInput Return Loss10 dB minDimensions3U high x 500mm x 19” wideOutput Return Loss10 dB minWeight6 kgs (TBC)System ControlColourWhite 00-E-55 semi-glossRemote ControlAlarmsVia RS232/485 serial port orEthernet. 10/100Base T. TCP/IP,SNMP or IRD voltageEthernet, serial and a dry contactalarm port on rear panel for PSUfailureQuad <strong>Matrix</strong>Key FeaturesHot-swap RF and CPU modulesEnvironmentalOperating temperature 0 to 45˚CLocationIndoor use onlyDual redundant, hot-swap power suppliesLNB Powering 0/13/18V DC & 22KHz ToneRemote Control via Ethernet port, serial port, or 13/18V DC& 22KHz tone on/off on RF output portsStorage temperatureHumidity-20˚C to +75˚C85% non-condensingLNB current monitoringDry contact alarm port for PSU failure<strong>ETL</strong> SYSTEMS LIMITEDColdwell Radio StationMadleyHerefordEngland HR2 9NETELEPHONE+44 (0)1981 259020EMAILinfo@etlsystems.comFACSIMILE+44 (0)1981 259021WEBwww.etlsystems.comV 1.0.1 E&OE